Fire protection systems RP-hermetic 50 E(W) 30-120, RP-hermetic FINELINE E(W) 30, RP-hermetic 55N FP E(W) 30-60, RP-ISO-hermetic 70 FP EI 30-90, RP-ISO-hermetic EI 30-120, RP-ISO-hermetic 45N EI 30-120, RP-ISO-hermetic 60N EI 30-120
Windows, Doors, Partition walls & Curtain walls
Fire protection doors and partitions Profile overview
Door
RP-hermetic 50 E(W) 30-120
RP 1658 AA RP 1658 CA
RP 1660 AA RP 1660 CA
RP 1652 AA
RP 1716 AA RP 1716 CA
RP 1659 AA RP 1659 CA
RP 1654 AA RP 1654 CA
Partition wall
RP 1656 AA RP 1656 CA
RP 1653 AA RP 1653 CA
RP 1813 AA RP 1813 CA
AA = steel S235 JR bright rolled, 6.000 mm CA = steel continiously hot dip coated, 6.000 mm CC = steel continiously hot dip coated, 5.000 mm XA = stainless steel 1.4301 (304), surface raw material 2B, 6.000 mm XQ = stainless steel 1.4301 (304), surface raw material 2B, 2.800 mm ZA = stainless steel 1.4301 (304), outer surface ground, size 220-240, foiled, 6.000 mm Optional surface treatment for AA BA = galvanized (Unit galvanizing), DIN EN ISO 1461, on both sides minimum 70 µm, 6.000 mm DA = zinc-plated (blue/yellow chromed), DIN 50961, outer layer minimum 8 µm, 6.000 mm
Glazing beads RP 1638 CA RP 1591 CA
1
Fire test Pilkington, Gelsenkirchen, Germany
2
Designhotel, Kamen, Germany
3
Manufactum, Waltrop, Germany
4
Hansakontor Dortmund, Germany Manufactum, Waltrop, Germany
RP 1606 CA
RP 1668 CA
AL = aluminium EN AW 6060, state T66, 6.000 mm
RP 1657 CA
RP-hermetic 50 E(W) 30-120 60
5
RP 1637 CA
5
5
60
12
60
5
80 172
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
1
2
Fire protection partitions and openable windows Profile overview
Window
RP-hermetic FINELINE E(W) 30
RP 5325 CA
RP 5326 CA
RP 5330 CA
RP 5333 CA
RP 5327 CA
Partition wall
RP 5335 CA
RP 5329 CA
Glazing beads 403 310 AL 403 320 AL 403 330 AL 403 340 AL
403 370 AL
403 360 AL
403 420 AL 403 430 AL 403 470 AL
RP-hermetic FINELINE E(W) 30 25 14
4
36
4
7
25
4
4
7
4
4
36
36
35
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
3
4
5
RP-hermetic 55N FP E(W) 30-60 Profile overview
Door
RP-hermetic 55N FP E(W) 30-60
Partition wall
30
30
60
RP 91 301 0 RP 91 301 2 RP 91 301 3 RP 91 301 4
60
RP 91 302 0 RP 91 302 2 RP 91 302 3 RP 91 302 4
30
30
15
60
55
55
49
60
50
RP 91 304 0 RP 91 304 2 RP 91 304 3
RP 91 311 0 RP 91 311 2 RP 91 311 3 RP 91 311 4
50
RP 91 312 0 RP 91 312 2 RP 91 312 3 RP 91 312 4
80
50
80
RP 91 313 0 RP 91 313 2 RP 91 313 3 RP 91 313 4
RP 91 314 0 RP 91 314 2 RP 91 314 3 RP 91 314 4
80
50
40
55
60
35
80
RP 91 310 0 RP 91 310 2 RP 91 310 3 RP 91 310 4
30
100
50
RP 91 321 0 RP 91 321 2 RP 91 321 3 RP 91 321 4 15
80
RP 91 331 0 RP 91 331 2 RP 91 331 3 RP 91 331 4
100
RP 91 340 0 RP 91 340 2 RP 91 340 3 RP 91 340 4
50
40
90
80
70
RP 91 351 0 RP 91 351 2 RP 91 351 3 RP 91 351 4
RP 91 360 0 RP 91 360 2 RP 91 360 3 RP 91 360 4
60
RP 91 361 0 RP 91 361 2 RP 91 361 3 RP 91 361 4 40
60
70
55
49
50
80
RP 91 330 0 RP 91 330 2 RP 91 330 3 RP 91 330 4
52
70
RP 91 320 0 RP 91 320 2 RP 91 320 3 RP 91 320 4
50
RP 91 362 0 RP 91 362 2 RP 91 362 3 RP 91 362 4
70
RP 91 364 0 RP 91 364 2 RP 91 364 3 RP 91 364 4
35
RP 91 367 0 RP 91 367 2 RP 91 367 3 RP 91 367 4
RP 91 370 0 RP 91 370 2 RP 91 370 3 RP 91 370 4
RP 91 371 0 RP 91 371 2 RP 91 371 3 RP 91 371 4
90
RP 91 380 0 RP 91 380 2 RP 91 380 3 RP 91 380 4
20
80
RP 92 301 0 RP 92 301 2 RP 92 301 3
RP 91 381 0 RP 91 381 2 RP 91 381 3 RP 91 381 4
50
RP 92 302 0 RP 92 302 2 RP 92 302 3 RP 92 302 4
Glazing beads
RP 92 001 2 RP 92 001 3* RP 92 001 4*
RP 92 002 2 RP 92 002 3* RP 92 002 4*
RP 92 003 2 RP 92 003 3 RP 92 003 4
RP 92 004 2 RP 92 004 3 RP 92 004 4
RP 92 005 2 RP 92 005 3 RP 92 005 4
RP 92 006 2 RP 92 006 3 RP 92 006 4
RP 92 007 2 RP 92 007 3 RP 92 007 4
RP 92 008 2 RP 92 008 3 RP 92 008 4
End digit 0 = steel S235JR, bright rolled, 6.000 mm End digit 1 = aluminium EN AW 6060, state T66, 6.000 mm End digit 2 = steel S280GD continuously hot-dip coated, 6.000 mm End digit 3 = stainless steel, 1.4401 (316), surface raw material 2B, 6.000 mm End digit 4 = stainless steel, 1.4401 (316), outer surfaces ground , size 400, foiled, 6.000 mm End digit 5 = Aluminium black *) = Price and delivery time on request
1
Fire test RP-hermetic 55N FP E(W) 30-60
2
Hospital St. Joseph, Duisburg, Germany
RP-hermetic 55N FP E(W) 30-60 Doors 6
60
7,5
7,5
60
6
40
7,5
136
60
100
7,5
50
20
146
Fixed glazing 7,5
30
50
7,5
30
7,5
70
Glazing - alternative stop
Glazing - centered, alternative
Glazing - alternative wet glazing
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
1
2
RP-ISO-hermetic 70 FP EI 30 Profile overview Door
90%
RP-ISO-hermetic 70 FP EI 30
RPF 91 501 2 RPF 91 501 3 RPF 91 501 4
RPF 91 530 2 RPF 91 530 3 RPF 91 530 4
RPF 91 502 2 RPF 91 502 3 RPF 91 502 4
RPF 91 531 2 RPF 91 531 3 RPF 91 531 4
RPF 91 560 2 RPF 91 560 3 RPF 91 560 4
RPF 91 551 2 RPF 91 551 3 RPF 91 551 4
1
Designhotel Kamen, Germany
2
Welser Profile, Bönen, Germany
3
4-6
Hansakontor, Dortmund, Germany
RPF 91 504 2 RPF 91 504 3
RPF 91 532 2 RPF 91 532 3 RPF 91 532 4
Partition wall
RPF 91 510 2 RPF 91 510 3 RPF 91 510 4
RPF 91 511 2 RPF 91 511 3 RPF 91 511 4
RPF 91 533 2 RPF 91 533 3 RPF 91 533 4
RPF 91 563 2 RPF 91 563 3 RPF 91 563 4
RPF 91 520 2 RPF 91 520 3 RPF 91 520 4
RPF 91 540 2 RPF 91 540 3 RPF 91 540 4
RPF 91 570 2 RPF 91 570 3 RPF 91 570 4
RPF 91 521 2 RPF 91 521 3 RPF 91 521 4
RPF 91 541 2 RPF 91 541 3 RPF 91 541 4
RPF 91 580 2 RPF 91 580 3 RPF 91 580 4
RPF 91 550 2 RPF 91 550 3 RPF 91 550 4
RP 92 101 2 RP 92 102 2 RP 92 101 3 RP 92 102 3 RP 92 102 4
Glazing beads
RP 92 002 2 RP 92 002 3 RP 92 002 4
RP 92 003 2 RP 92 003 3 RP 92 003 4
RP 92 004 2 RP 92 004 3 RP 92 004 4
RP 92 005 2 RP 92 005 3 RP 92 005 4
RP 92 006 2 RP 92 006 3 RP 92 006 4
RP 92 007 2 RP 92 007 3 RP 92 007 4
RP 92 008 2 RP 92 008 3 RP 92 008 4
RP 92 009 2 RP 92 009 3 RP 92 009 4
End digit 0 = steel S235JR, bright rolled, 6.000 mm End digit 1 = aluminium EN AW 6060, state T66, 6.000 mm End digit 2 = steel S280GD continuously hot-dip coated, 6.000 mm End digit 3 = stainless steel, 1.4401 (316), surface raw material 2B, 6.000 mm End digit 4 = stainless steel, 1.4401 (316), outer surfaces ground , size 400, foiled, 6.000 mm
Fire test RP-ISO-hermetic 70 FP 1
2
3
RP-ISO-hermetic 70 FP EI 30 Doors 50
70
6
5
5
70
146
50
50
5
166
70
5
80
100
5
6
6
10
146
Fixed glazing 5
50
5
70
60
5
100
Alternative glazing
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
4
5
Advantages at a glance: modular system - one profile for all classifications! • Realization in steel and stainless steel • one profile for different fire resistant categories – classifications are achieved by using different isolators – uniform processing • glazing bead stick-system • same face width for doors and partition walls • Doors: up to 54 mm filling thickness possible • profiles are available with or without filling • screwed square and rectangle profiles as well as angles as glazing beads possible 6
RP-ISO-hermetic 70 FP EI 60/EI 90 Profile overview
Door
Partition wall
RP-ISO-hermetic 70 FP EI 60/EI 90
RPG 91 502 2
RPG 91 504 2
RPG 91 532 2
RPG 91 533 2
Montessori Primary School Moenchengladbach, Germany
RPG 91 563 2
2
Fire test Partition wall, Germany
Glazing beads
3
Dubai Airport, UAE
1
4-6
Firestation New York, USA
RP 92 003 2
1
RPG 91 511 2
RPG 91 570 2
RP 92 004 2
RP 92 005 2
RPG 91 521 2
RPG 91 541 2
RPG 91 580 2
RPG 91 551 2
RPL 91 560 2
RPL 91 570 2
RPG 91 531 2
RPG 91 560 2
RPL 91 580 2
End digit 0 = steel S235JR, bright rolled, 6.000 mm End digit 1 = aluminium EN AW 6060, state T66, 6.000 mm End digit 2 = steel S280GD continuously hot-dip coated, 6.000 mm End digit 3 = stainless steel, 1.4401 (316), surface raw material 2B, 6.000 mm End digit 4 = stainless steel, 1.4401 (316), outer surfaces ground , size 400, foiled, 6.000 mm
RP 92 006 2
2
3
RP-ISO-hermetic 70 FP EI 60/EI 90 Door 50
6
70
5
5
70
146
50
50
5
166
70
5
80
100
5
6
6
10
146
Fixed glazing 5
50
5
70
60
5
100
Alternative glazing
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
4
5
6
Fire protection doors and partitions Profile overview Door
RP-ISO-hermetic EI 30 105
Partition wall
105
105
105
80
80
105
105
80
55
65
80
38
17
25
RP 3400 CA RP 3400 XA RP 3400 ZA
25
38
17
25
63
RP 3410 CA RP 3410 XA RP 3410 ZA
17
25
25
RP 3418 CA RP 3418 XA RP 3410 ZA
55
25
RP 3415 CA RP 3415 XA RP 3415 ZA
25
55
25
55
RP 3416 CA RP 3416 XA RP 3416 ZA
25
38
RP 3421 CA RP 3421 XA RP 3421 ZA
17
25
25
RP 3470 CR RP 3470 XR RP 3470 ZR
38
17
25
63
RP 3471 CR RP 3471 XR RP 3471 ZR
17
25
55
RP 3472 CR RP 3472 XR RP 3472 ZR
25
RP 3403 CA RP 3403 XA RP 3403 ZA
RP 3404 CA RP 3404 XA RP 3404 ZA
RP-ISO-hermetic EI 60 105
105
105
105
80
80
105
105
105
65
80
38
17
25
38
25
17
25
17
63
25
25
RP 3218 CA RP 3218 XA RP 3218 ZA
RP 3210 CA RP 3210 XA RP 3210 ZA
RP 3200 CA RP 3200 XA RP 3200 ZA
55
25
RP 3415 CA RP 3415 XA RP 3415 ZA
25
55
25
55
25
RP 3221 CA RP 3221 XA RP 3221 ZA
RP 3216 CA RP 3216 XA RP 3216 ZA
38
25
25
17
RP 3270 CR RP 3270 XR RP 3270 ZR
38
17
RP 3271 CR RP 3271 XR RP 3271 ZR
25
17
63
25
RP 3272 CR RP 3272 XR RP 3272 ZR
25
55
25
RP 3217 CA RP 3217 XA RP 3217 ZA
RP-ISO-hermetic EI 90 105
105
105
105
80
80
105
105
105
70
80
38
17
25
RP 3000 CA RP 3000 XA RP 3000 ZA
25
38
17
25
63
RP 3010 CA RP 3010 XA RP 3010 ZA
17
25
25
RP 3018 CA RP 3018 XA RP 3018 ZA
RP 3015 CA RP 3015 XA RP 3015 ZA
55
25
25
55
25
RP 3016 CA RP 3016 XA RP 3016 ZA
55
RP 3021 CA RP 3021 XA RP 3021 ZA
25
38
17
RP 3070 CR RP 3070 XR RP 3070 ZR
25
25
38
RP 3071 CR RP 3071 XR RP 3071 ZR
17
25
63
17
25
RP 3072 CR RP 3072 XR RP 3072 ZR
25
55
25
RP 3017 CA RP 3017 XA RP 3017 ZA
RP-ISO-hermetic EI 120 105
105
90
80
55
25
RP 9421 CA RP 9421 XA RP 9421 ZA
25
55
25
25
RP 9416 CA RP 9416 XA RP 9416 ZA
55
25
RP 9417 CA RP 9417 XA RP 9417 ZA
AA = steel S235 JR bright rolled, 6.000 mm CA = steel continiously hot dip coated, 6.000 mm CC = steel continiously hot dip coated, 5.000 mm CR = steel continiously hot dip coated, 3.000 mm XA = stainless steel 1.4301 (304), surface raw material 2B, 6.000 mm XR = stainless steel 1.4301 (304), surface raw material 2B, 3.000 mm XQ = stainless steel 1.4301 (304), surface raw material 2B, 2.800 mm ZA = stainless steel 1.4301 (304), outer surface ground, size 220-240, foiled, 6.000 mm ZR = stainless steel 1.4301 (304), outer surface ground, size 220-240, foiled, 3.000 mm Optional surface treatment for AA BA = galvanized (Unit galvanizing), DIN EN ISO 1461, on both sides minimum 70 µm, 6.000 mm DA = zinc-plated (blue/yellow chromed), DIN 50961, outer layer minimum 8 µm, 6.000 mm
Glazing beads 18
23
28
33
38
25
15
400 630 CA
400 510 CA 400 790 XA 400 799 ZA
400 520 CA 400 800 XA 400 809 ZA
400 530 CA 400 810 XA 400 819 ZA
400 540 CA 400 820 XA 400 829 ZA
400 550 CA
AL = aluminium EN AW 6060, state T66, 6.000 mm
1
RP-ISO-hermetic EI 30 8
8
55
14
55
8
65
65
55
80
The system • stable closed profiles • asbestos-free insulation • economic
174
RP-ISO-hermetic EI 60 8
8
55
14
55
8
The steel material • high resistance capability • long lasting and secure • shockproof and stable • environmentally friendly • maintenance friendly • pre-galvanised strip
65
65
55
80
174
RP-ISO-hermetic EI 90 8
8
55
14
55
8
70
70
55
80
174
RP-ISO-hermetic EI 120 1
Fire test, Germany
2
Hospital St. Joseph, Duisburg, Germany
3
Town hall, Germany
4
Welser Profile, Boenen, Germany
8
90
2
8
55
8
The architecture • flush fitting • high transparency • attractive design • multi-functional The processing • simple and economic • high inherent stability frames • manufacturing friendly wall thickness 1.8 mm • screwed glazing bead systems • dry and wet glazing
90
55
Transparent fire protection • fabricated from steel and glass, protects against fire, smoke and radiant heat • Classification EI 30 to EI 120
80
80
3
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
4
Fire protection curtain walls Profile overview
Curtain wall
RP-ISO-hermetic 45N EI 30-120
RP 1788 CA RP 1788 CI RP 1788 XA RP 1788 ZA
RP 1789 CA RP 1789 CI
46
10
10
430 050 CN
RP 1790 CA RP 1790 CI RP 1790 XA RP 1790 ZA
RP 1815 CA RP 1815 CI
45
RP 1787 CA RP 1787 XA RP 1787 ZA
42,2
42,2
RP 1786 CA
15
430 055 CA
411 550 CNx
18
15
411 560 CNx
18
413 630 AL
21
413 640 AL
413 690 AL
RP-ISO-hermetic 60N EI 30-120
3
Train station Frankfurt, Germany
4
Train station Frankfurt, Germany
5
Fire test curtain wall RP-ISO-hermetic 45N
RP 1800 CA
RP 1802 CA RP 1802 CI RP 1802 XA RP 1802 ZA
10
10
430 060 CN
430 065 CA
1
RP 1804 CA RP 1804 CI RP 1804 XA RP 1804 ZA
RP 1806 CA RP 1806 CI RP 1806 XA RP 1806 ZA
60
Fire test curtain wall, France
61
2
57,2
Fire test curtain wall, France
57,2
1
21
411 530 CNx
24
411 540 CNx
15
413 510 AL
18
413 520 AL
21
24
413 530 AL
2
413 540 AL
AA = steel S235 JR bright rolled, 6.000 mm CI = steel continiously hot dip coated, 7.500 mm CA = steel continiously hot dip coated, 6.000 mm CC = steel continiously hot dip coated, 5.000 mm XA = stainless steel 1.4301 (304), surface raw material 2B, 6.000 mm XQ = stainless steel 1.4301 (304), surface raw material 2B, 2.800 mm ZA = stainless steel 1.4301 (304), outer surface ground, size 220-240, foiled, 6.000 mm CN = stainless steel 1.4401 (316) surface raw material 2 B CNx = stainless steel 1.4401 (316) outer surfaces ground, size 220-240, foiled Optional surface treatment for AA BA = galvanized (Unit galvanizing), DIN EN ISO 1461, on both sides minimum 70 µm DA = zinc-plated (blue/yellow chromed), DIN 50961, outer layer minimum 8 µm AL = aluminium EN AW 6060, state T66
Fire protection glazing in a mulliontransom construction
The slim and multi-functional RP-curtain wall systems, with mullion-transom construction, together with their specially tested fireproof glazing, have a proven suitability for a range of fire retardation times up to 120 minutes. The structures can equally well be used for constructions over several stories, for curtain walls or as separating structures.
RP-ISO-hermetic 45N EI 30-120
Through their narrow face widths of 45 to 60 mm, slim and transparent architectural requirements can be fulfilled, and this in combination with meeting high static requirements. The fire protection characteristics are achieved by this construction alone, through the selection of filling elements and accessory components, without the need for additional measures. Different depths of building profile, from 45 to 180 mm, allow the greatest possible design variation. Fundamental
RP-ISO-hermetic 60N EI 30-120
3
corrosion protection is guaranteed through complete (inside/ outside) pre-galvanizing. A tested and proven sealing system with overlapping transom seals where they meet the mullions, guarantees a solution with a high degree of tightness for the internal seals and for the external glazing, giving an altogether high system tightness for external applications.
4
Application of glazing seals depends on glass type, classification, fire resistance period and corresponding approvals. National requirements have to be observed.
5
High-quality service & dedicated support
Health Occupational safety and the protection of health are the mainstay of any successful enterprise. Our long-standing corporate principles reach far beyond the confines of accident prevention. Health and well-being are an unwavering concern of our company.
Environmental protection We are responsible for the environment we inhabit. A stable environment is key to our success as a company, both now and in future. Environmental protection, when practised on a daily basis, is a prerequisite for building our common future. For this to happen, all employees need to pull together in one direction.
Quality eamless quality control at all stages of the production process are a sure-fire guarantee of RP Technik‘s commitment to unimpeachable quality when it comes to delivering impeccable high-grade profile systems.
CD You can find all the technical data you need relating to RP Technik‘s profile systems and their accessory components on the service and documentation CD..
Sliding elements
Windows
Partition walls
Doors
Add-on curtain wall system
Curtain walls
Profile systems
National requirements, directives and building regulations specific to the various Federal States must be observed while taking into account evidence garnered from tests and any approvals related thereto.
Evidence
RP-ISO-hermetic 45N RP-ISO-hermetic 60N RP-tec 55 RP MULTITOP 50/60
Outlet
RP-tec 50-1 RP-tec 55-1 RP-tec 50-1 HA RP-tec 55-1 HA RP-tec 50-1 HA plus RP-tec 55-1 HA plus
A long-stAnding And successFul pArtnersHip
RP-tec 60-1 RP-tec 60-1 HA RP-tec 80-1
Close partnership with customers, translated into practical, day-to-day cooperation is a solid foundation for success. RP Technik is your unswerving partner for the development of steel profiles. From architects to planners, our customers benefit from a plethora of skills off ered by a group of specialists working for a company which is both an expert in its field and active on the world stage. Insider knowledge of the industry and the full panoply of experience garnered from years of developing steel profiles mean partners of RP Technik have a clear advantage on the world markets, our unrelenting focus being on personal safety and building protection.
RP-tec 80-1 HA RP-ISO-hermetic 70 RP-ISO-hermetic 70 RP-ISO-hermetic 70 plus RP-ISO-hermetic 70 plus RP-hermetic FINELINE
RP-hermetic 40
RP-Design 50 RP-hermetic 50 RP-hermetic 55N RP-hermetic 55N RP-hermetic 55N FP RP-hermetic 75 RP-hermetic 75 FB RP-ISO-hermetic EI 30 RP-ISO-hermetic EI 60 RP-ISO-hermetic EI 90 RP-ISO-hermetic EI 120 RP-ISO-hermetic 70 FP
Wind load
Air permeability
Rain perme- Impact resistance ability
Bulletproof
Burglarresistant
Thermal insulation
Sound insulation
Finger trap protection
Duration function
E
EW
EI
Smoke protection
thermally insulated
non thermally insulated
≈1000°C
EI
E
≈1000°C
≈1000°C
EW
Welser Profile Deutschland GmbH Edisonstraße 23 59199 Bönen / DEUTSCHLAND Tel (+49 2383) 914-0 Fax (+49 2383) 914-5555
[email protected]
kW/m2 kW/m2
▲T ≤ 140°C
Welser Profile Austria GmbH In the event of a fire, the fire separating function must be preserved and so prevent the spread of flames and smoke, for the specified period. Apart from these fundamental characteristics, components, which possess an EI classification, must maintain the surface temperature on the glass and frameworks, on the side facing away from the fire, on average, at not more than 140 K above the initial temperature. Furthermore, at no point may the rise in temperature be higher than 180 K. This ensures the protection of people and property in the neighbouring rooms for an appropriate period of time, and makes possible a safe evacuation of the building concerned in the intermediate time.
In contrast to EI classified components, these fire separation elements only provide basic protection from flames and smoke. In the event of a fire, radiant heat transmission is largely unobstructed, so that people can only remain for a short time near the side facing away from the fire, i.e. in neighbouring rooms. Furnishings, located in the proximity of such constructions, may catch fire because - of the almost unhindered heat radiation - and will thus contribute to the further propagation of the fire.
3341 Ybbsitz / ÖSTERREICH Tel (+43 7443) 800-0 Fax (+43 7443) 800-4111
[email protected]
In addition to the characteristics of E classified components, fire protection closures must reduce the transmission of heat radiation, meeting EW requirements. At a distance of 1 m from the relevant component, the radiant heat at the end of the specified period may not exceed more than 15 kW/m2 on the opposite side to the fire. Thus, a relatively safe path for pedestrians can be assured along escape and emergency routes.
3264 Gresten / ÖSTERREICH Tel (+43 7487) 410-0 Fax (+43 7487) 410-4111
RP Technik GmbH Profilsysteme Edisonstraße 4 59199 Bönen / DEUTSCHLAND Tel (+49 2383) 91 49-0 Fax (+49 2383) 91 49-222
[email protected]
Ferdinand-Braun-Straße 26 74074 Heilbronn / DEUTSCHLAND Nordstraße 8 5301 Eugendorf / ÖSTERREICH
Fire protection certificates
1-leaf doors
2-leaf doors
window
partitions
curtain walls
RP-hermetic 50 E(W) 30-120 RP-hermetic FINELINE E(W) 30 RP-hermetic 55N FP E(W) 30-60 RP-ISO-hermetic 70 FP EI 30 RP-ISO-hermetic 70 FP EI 60/EI 90
Your distribution partner for fire protection systems:
RP-ISO-hermetic EI 30 RP-ISO-hermetic EI 60 RP-ISO-hermetic EI 90 RP-ISO-hermetic EI 120 RP-ISO-hermetic 45N EI 30-120 RP-ISO-hermetic 60N EI 30-120 When putting together applications, the respective national requirements, guidelines and building regulations of the country concerned must be observed with consideration of the available test certificates and their approval.
Imprint © RP Technik GmbH Profilsysteme Layout and Outwork: arche-nova.at Printed by Druckerei Queiser • 1st edition-EN-09.2014 Änderungen und Irrtümer vorbehalten. Modifications and errors reserved. Sous réserve de modifications et d’erreurs. Art.-Nr. 1164111