ETIII SA Implant System

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:45 AM Page 1 Edition 6 / 2014 ETIII SA Implant System HIOSSEN Inc...
Author: Baldric Merritt
53 downloads 1 Views 2MB Size
ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:45 AM Page 1

Edition 6 / 2014

ETIII SA Implant System

HIOSSEN Inc. www.hiossen.com 85 Ben Fairless Dr., Fairless Hills, PA 19030, USA TEL : 1-888-678-0001 FAX : 1-267-759-7004

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:46 AM Page 2

ETIII SA Implant System

For more information visit www.hiossen.com

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:46 AM Page 3

SA Surface

What is Hiossen’s SA Surface?

SA

x 2K

x 2K

x 4K

x 4K

RBM

S A stands for Sand blasted and Acid etched. When compared with traditional RBM surface treatment methods, Hiossen’s SA surface has shown a 45% improvement in available surface area. Additionally, Hiossen’s proprietary SA surface treatment has shown a substantial quickening of the gene expression, cell differentiation, and proliferation that are central to osseointegration. What does this mean for your patients? 3 Faster bone healing: 20% Faster than traditional RBM surface treatment 3 Earlier loading times: As soon as 6 weeks after implant placement

1

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:46 AM Page 4

ETIII SA Implant ETIII SA

Key Design Features of the Hiossen ETIII SA Implant

• Self-sealing 11° Morse taper joins the abutment to the implant • Hermetic seal minimizes micro movement reducing percolation of saliva & bacteria • Slightly smaller abutment diameter keeps the interface away from the bone • Aggressive self threading design • Lower sensitivity to drill size • Maintains implant path

• Self-tapping • Ability for path change • Secure initial stability

ET III SA Implant

2

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 5

ETIII SA Implant ETIII SA Fixtures ETIII SA Fixtures come in four different diameters (Ø3.5, Ø4.0, Ø4.5 and Ø5.0), and are available in both no-mount and pre-mounted configurations (Fixture + Mount + Cover screw). ETIII SA UW Fixtures come in two different diameters (Ø6.0, Ø7.0). They are available in pre-mounted configuration only.

Pre-Mounted Fixture (Simple Mount) Fixture + Mount + Cover Screw : A + Product Code (Ex:AET3R4011S)

Hex 1.2

Hex 1.2

ET III SA Fixture Ø3.5

ET III SA Fixture Ø4.0, Ø4.5, Ø5.0

Hex 1.2

ET III SA UW Fixture Ø6.0, Ø7.0

No Mount Fixture Fixture : + Cover Screw : C + Product Code (Ex:CET3R4011S)

Ø3.5

3

ETIII SA Implant System Catalog

Ø4.0

Ø4.5

Ø5.0

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 6

ETIII SA

ETIII SA Fixture's internal connection come in two different sizes. Mini fixtures (Ø3.5) has a 2.1mm internal connection and Regular fixtures (Ø4.0, Ø4.5, Ø5.0) has a 2.5mm internal connection. Mini Fixtures (Ø3.5) only accept abutments color coded in yellow and Regular Fixtures (Ø4.0, Ø4.5, Ø5.0) accept all abutment color coded in green.

Hex 2.1

Hex 2.5

2.8 Hex depth

2.8 Hex depth

Mini connection

Cover Screw

Regular connection

Color

Purple

Green

Fixture

3.5mm

4.0mm, 4.5mm, 5.0mm

Code

Discontinued

GSCS40S-G/GSCS40S-B

Packing unit: cover screw Use a long cover screw when fixture is implanted under the bone level 1.2 hex driver Tightening torque: 5~8Ncm

0.4mm

Mini

Regular

ET III SA Implant

4

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 7

ETIII SA Implant ETIII SA Fixtures

M

S Hex 2.1

Hex 2.5

Diameter Ø3.5 D

L

8.5mm

10mm

11.5mm

Regular

13mm

Connection

Mini

Diameter

Ø3.5

Length (mm)

Mini

8.5 10

ET3M3510S

11.5

ET3M3511S

13

ET3M3513S

15

ET3M3515S

15mm

Connection

Diameter Ø4.0

Diameter

L

8.5mm

10mm

Regular

11.5mm

13mm

Length (mm)

D

7mm

Ø4.0 7

ET3R4007S

8.5

ET3R4008S

10

ET3R4010S

11.5

ET3R4011S

13

ET3R4013S

15

ET3R4015S

Connection Diameter

10mm

Regular

11.5mm

13mm

Length (mm)

L

Ø4.5 7

ET3R4507S ET3R4508S

10

ET3R4510S

11.5

ET3R4511S

13

ET3R4513S

15

ET3R4515S

15mm

Connection

Diameter Ø5.0

Diameter

L

5

8.5mm

10mm

11.5mm

ETIII SA Implant System Catalog

13mm

15mm

Length (mm)

D

7mm

Regular

8.5

D

8.5mm

Regular

15mm

Diameter Ø4.5

7mm

ET3M3508S

Regular Ø5.0

7

ET3R5007S

8.5

ET3R5008S

10

ET3R5010S

11.5

ET3R5011S

13

ET3R5013S

15

ET3R5015S

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 8

Drilling Sequence for ETIII - Taper Drill *ETIII Implants require the Taper Kit (HTAPEK)

ETIII SA

Ø3.5 Fixture ( Length :10mm )

Bone Quality

Ø2.2 Drill

Ø3.0 Drill

Ø3.5 Taper Drill

Ø3.5 Taper Cortical Driill

Soft Normal Hard

Ø3.5 Fixture Implant Placement

Ø4.0 Fixture ( Length :10mm )

Bone Quality

Ø2.2 Drill

Ø3.5 Taper Drill

Ø4.0 Taper Drill

Ø4.0 Taper Cortical Driill

Soft Normal Hard

Ø4.0 Fixture Implant Placement

Ø4.5 Fixture ( Length :10mm )

Bone Quality

Ø2.2 Drill

Ø3.5 Taper Drill

Ø4.0 Taper Drill

Ø4.5 Taper Drill

Soft Normal Hard

Ø4.5 Taper Cortical Driill Ø4.5 Fixture Implant Placement

Ø5.0 Fixture ( Length :10mm )

Bone Quality Soft Normal Hard

Ø2.2 Drill

Ø3.5 Taper Drill

Ø4.5 Taper Drill

Ø5.0 Taper Drill

Ø5.0 Taper Cortical Driill Ø5.0 Fixture Implant Placement

ET III SA Implant

6

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 9

ETIII UW Implant ETIII SA UW Fixtures Regular

Connection

Diameter Ø6.0

Regular

Diameter Ø6.0

Length (mm)

D

L

7.0mm

8.5mm

10mm

11.5mm

AET3R6007S

8.5

AET3R6008S

10

AET3R6010S

11.5

AET3R6011S

13

AET3R6013S

13mm

Diameter Ø7.0

Regular

Ø6.0 7

Connection

Regular

Diameter Length (mm)

Ø6.8 D

L

7.0mm

8.5mm

10mm

11.5mm

Ø7.0 7

AET3R7007S

8.5

AET3R7008S

10

AET3R7010S

11.5

AET3R7011S

13

AET3R7013S

13mm

Drilling Sequence for ETIII UW - Taper Drill *ETIII UW Implants require the Ultra Kit (HULTRK)

Ø6.0 Fixture ( Length :10mm )

Bone Quality

Ø2.0 Drill

Ø2.0/3.0 Pilot Drill

Ø3.0 Drill

Ø3.0/3.8 Pilot Drill

Ø3.8 Drill

Ø4.6 Drill

Soft Normal Hard

Ø5.2 Direct Drill

Ø5.5 Ø6.0 Direct Drill Cortical Drill

Ø6.0 Fixture

Implant Placement

Ø7.0 Fixture ( Length :10mm )

Bone Quality Soft Normal Hard

7

ETIII SA Implant System Catalog

Ø2.0 Drill

Ø2.0/3.0 Pilot Drill

Ø3.0 Drill

Ø3.0/3.8 Pilot Drill

Ø3.8 Drill

Ø4.6 Drill

Ø6.5 Ø5.5 Ø6.2 Ø7.0 Ø7.0 Direct Drill Direct Drill Direct Drill Cortical Drill Fixture

Implant Placement

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 10

Healing Abutment Prosthetic Components

Healing Abutment Mini connection 1.2

Mini

1.2

H

3.0

4.0

5.0

7.0

Ø4.0

4003M

4004M

4005M

4007M

Ø4.5

4503M

4504M

4505M

4507M

D

Ø4.0

Ø4.5

H

Fixture Level

Regular connection 1.2

1.2

1.2

Regular

1.2

H

3.0

4.0

5.0

7.0

Ø4.0

4003R

4004R

4005R

4007R

Ø5.0 Ø6.0 Ø7.0

5003R 6003R 7003R

5004R 6004R 7004R

5005R 6005R 7005R

5007R 6007R 7007R

D

Ø4.0

Ø5.0

Ø6.0

Ø7.0

• Order

Code : ETHLA + item code ex) ETHLA + 4503M = ETHLA4503M • Use a 1.2 hex driver • Packing unit : Healing abutment • Tightening torque : Hand tightening (less than 10Ncm)

H

Fixture Level

Healing Abutment Selection Guide Healing ABT. (H)

3

4

5

7

Abutment (G/H)

1

2 or 3

3 or 4

more than 5

Prosthetic Components

8

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 11

Transfer Abutment

Transfer Abutment Cement retained restoration H

Mini

1.2

D

4.5mm

Type G/H

4.5mm 5.5 H G/H

Hex

Non-Hex

1.0

4515MHW

4515MNW

2.0

4525MHW

4525MNW

3.0

4535MHW

4535MNW

4.0

4545MHW

4545MNW

5.0

4555MHW

4555MNW

Fixture Level

Hex

Non-Hex

1.2

D

H

5.0mm H G/H

5.5

Fixture Level

Hex

5.0mm

Type G/H

Non-Hex

Hex

Non-Hex

1.0

5015MHW

5015MNW

2.0

5025MHW

5025MNW

3.0

5035MHW

5035MNW

4.0

5045MHW

5045MNW

5.0

-

-

• Order

code : HGTFA + item code ex) HGTFA + 4515MHW = HGTFA4515MHW • Used for making general cement-type prosthesis • 11° taper connection enhances safety • Gingival gold color for aesthetic effect • Cross-section design prevents prosthesic restoration • Used with 1.2 hex driver • Tightening torque: 20Ncm (mini), 30Ncm (Regular)  Includes EbonyGold abutment screw

Regular 1.2

D

4.5mm H H G/H Fixture Level

Hex

5.5

Non-Hex

• Order

4.5mm

D G/H

Hex

Non-Hex

1.0

4515SHW

4515SNW

2.0

4525SHW

4525SNW

3.0

4535SHW

4535SNW

4.0

4545SHW

4545SNW

5.0

4555SHW

4555SNW

code : HGTFA + item code ex) HGTFA + 4515SHW = HGTFA4515SHW

9

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 12

Prosthetic Components

Transfer Abutment Cement retained restoration

Regular 1.2

D

5.0mm

H

H G/H

4.0

Fixture Level

Hex

5.0mm

D G/H

Non-Hex

5.5

7.0

Hex

Non-Hex

1.0

5014SHW

5014SNW

2.0

5024SHW

5024SNW

3.0

5034SHW

5034SNW

4.0

5044SHW

5044SNW

5.0

5054SHW

5054SNW

1.0

5015SHW

5015SNW

2.0

5025SHW

5025SNW

3.0

5035SHW

5035SNW

4.0

5045SHW

5045SNW

5.0

5055SHW

5055SNW

1.0

5017SHW

5017SNW

2.0

5027SHW

5027SNW

3.0

5037SHW

5037SNW

4.0

5047SHW

5047SNW

5.0

5057SHW

5057SNW

• Order code : HGTFA + item code ex) HGTFA + 5014SHW = HGTFA5014SHW

6.0mm

1.2

D

H

H G/H

Hex

4.0

Non-Hex

5.5

7.0

6.0mm

D G/H

Hex

Non-Hex

1.0

6014SHW

6014SNW

2.0

6024SHW

6024SNW

3.0

6034SHW

6034SNW

4.0

6044SHW

6044SNW

5.0

6054SHW

6054SNW

1.0

6015SHW

6015SNW

2.0

6025SHW

6025SNW

3.0

6035SHW

6035SNW

4.0

6045SHW

6045SNW

5.0

6055SHW

6055SNW

1.0

6017SHW

6017SNW

2.0

6027SHW

6027SNW

3.0

6037SHW

6037SNW

4.0

6047SHW

6047SNW

5.0

6057SHW

6057SNW

• Order code : HGTFA + item code ex) HGTFA + 6014SHW = HGTFA6014SHW

Prosthetic Components

10

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 13

Transfer Abutment Components Fixture Lab Analog Code

Mini

Regular HGFLAS

Regular • Used

by dental laboratory to replicate the implant to impression coping and fixes to working model

• Locks

11

Mini HGFLAM

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 14

L

Mini

11 14 L

4.0mm

D

Type

Prosthetic Components

Fixture Transfer Impression Coping

Hex

4011MH

Non-Hex

4011MN

Hex

4014MH

Non-Hex

4014MN

Fixture Level

D

Hex

Non-Hex

Hex

L : 11

Non-Hex L : 14

Regular

L 11 L

14

D

Type

4.0mm

5.0mm

6.0mm

Hex

4011SH

5011SH

6011SH

Non-Hex

4011SN

5011SN

6011SN

Hex

4014SH

5014SH

6014SH

Non-Hex

4014SN

5014SN

6014SN

• Order

D

Hex

Non-Hex L : 11

Hex

Non-Hex L : 14

code : HGFTI + item code ex) HGFTI + 4011MH = HGFTI4011MH • Used for taking an impression with a ready-made tray • Triangular arc ( ) design improves identification following impression • Long and short types enhance convenience • The hex type is designed as a two-piece. The non-hex type is designed as a one-piece  Includes transfer coping and guide pin  Guide pins NOT sold separately

Fixture transfer impression coping

Registered triangle-circle

The fixture transfer impression coping allows easy and exact coping repositioning after the impression is made by using the triangle-circle structure ( ) for superior direction and position identification. And also the long/ short (12.5mm /9.5mm) feature overcomes path and intermaxillary interference. The vertical impression error can be prevented by blocking out the driver hex hole after connecting the coping.

Prosthetic Components

12

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:47 AM Page 15

Transfer Abutment Components Fixture Pick-up Impression Coping

L 11

Mini H

15

4.0mm

D

Type

Hex

4011MH

Non-Hex

4011MN

Hex

4015MH

Non-Hex

4015MN

L

Fixture Level D

L : 11

L : 15

Regular

L H

11 15

L

• Order

D

L : 11

13

L : 15

ETIII SA Implant System Catalog

D

Type

4.0mm

5.0mm

6.0mm

Hex

4011SH

5011SH

6011SH

Non-Hex

4011SN

5011SN

6011SN

Hex

4015SH

5015SH

6015SH

Non-Hex

4015SN

5015SN

6015SN

code : HGFPI + item code ex) HGFPI + 4011MH = HGFPI4011MH • Used for taking an impression with a customized tray • Impression coping designed with hole-in-one ; no need for resin fixation • Asymmetrical structure minimizes contact interference ( ) • Long and short types enhance convenience.  Includes pick-up coping and guide pin  Guide pin can be purchased separately

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 16

Mini

Length

Guide pin helght

Mini

Regular

L

11

Guide Pin (H)

15

Guide Pin (H)

4.0mm 0

00M

Prosthetic Components

Fixture Pick-up Guide Pin

Regular 4.0mm

5.0mm

6.0mm

00S

0.5

05M

05S*

0.5

05ML*

05SL*

• Order

code : HGFPG + item code ex) HGFPG + 00M = HGFPG00M • Use 1.2 hex driver • * Custom Order - Please consult your sales representative for details.

Prosthetic Components

14

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 17

Temporary Abutment Temporary Abutment Mini

1.2

G/H 1.0 3.0 G/H

4.0mm

D

Type

Hex

401MHT

Non-Hex

401MNT

Hex

403MHT

Non-Hex

403MNT

Fixture Level D

Hex

Non-Hex G/H 1.2

1.0 3.0

4.5mm

D

Type

Regular

Hex

451SHT

Non-Hex

451SNT

Hex

453SHT

Non-Hex

453SNT

• Order

code : HGTPA + item code ex) HGTPA + 401MHT = HGTPA401MHT • Used to make temporary prosthesis (material : Ti Gr-3) • Easy to customize ; designed for maximum flexibility • Use 1.2 hex driver • Tightening torque : 20Ncm (mini / Regular)  Includes Ti abutment screw  Ti abutment screw can be purchased separately (Mini : HGATSMT, Regular : HGATSST)

G/H

D

Hex

Non-Hex

Quick Temporary Abutment Cement/Screw Retained Restoration

Mini

1.2

G/H 5.0

Fixture Level D

Non-Hex

Regular

1.2

G/H

D

Hex

15

Non-Hex

ETIII SA Implant System Catalog

4.5mm

5.5mm

Hex

HGQTA455MHT

HGQTA555RHT

Non-Hex

HGQTA455MNT

HGQTA555RNT

• Cement and screw reained restorations possible • Biocompatible Plastic (PEEK) • Titanium base: Provides stable connection • Maximum Use: 180 days in the oral cavity • Final torque: 20Ncm (Mini & Regular)

G/H

Hex

D

Type

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 18

Castable Abutment Prosthetic Components

GoldCast Abutment Cement or screw retained restoration

Mini

1.2

G/H

D

Type

1.0 3.0

4.0mm

Hex

401MHW

Non-Hex

401MNW

Hex

403MHW

Non-Hex

403MNW

G/H Fixture Level

G/H

D

Hex

1.0 1.2

Regular

D

Type

Non-Hex

3.0

4.5mm

Hex

451SHW

Non-Hex

451SNW

Hex

453SHW

Non-Hex

453SNW

• Order

code : HGGCA + item code ex) HGGCA + 401MHW = HGGCA401MHW • Used for cases with path and esthetic and spatial constraints • 11° taper connection for enhanced safety • Prosthesis must be cast with dental gold alloy • Melting point range of abutments (Au, Pt, Pd Alloy) : 1400°c ~ 1450°c (use of non-precious metal alloy for casting prohibited) • Use 1.2 hex driver • Tightening torque : 20Ncm (mini), 30Ncm (Regular)  Includes Ebony Gold abutment screw  Ebony Gold abutment screw can be purchased separately (Mini : HGATSM, Regular : HGATSS)

G/H

D

Hex

Non-Hex

NP-CAST Abutment Screw or Cement Retained Restoration

Mini

1.2

G/H

D

Type

1.0 10mm

3.0

4.0mm

Hex

HGNCA401MHW

Non-Hex

HGNCA401MNW

Hex

HGNCA403MHW

Non-Hex

HGNCA403MNW

G/H

Fixture Level D

Hex

Non-Hex

G/H

Regular

1.2

1.0 3.0

10mm

G/H

Fixture Level D

Hex

Non-Hex

D

Type

4.5mm

Hex

HGNCA451SHW

Non-Hex

HGNCA451SNW

Hex

HGNCA453SHW

Non-Hex

HGNCA453SNW

• Packing unit : Abutment + EbonyGold screw • Use for cases with path, aesthetic and spatial constraints • After customization, be sure to use only dental non-precious metal alloy for casting to make the prosthetis • Use the 1.2 hex driver • Tightening torque: 20Ncm(Mini), 20Ncm(Regular • Melting point: 1650ºC

Prosthetic Components

16

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 19

LOCATOR® Abutment & Components LOCATOR® Abutment

Mini

D

G/H

1.0 2.0 3.0 4.0 5.0

1.5mm G/H Fixture level

3.7mm

3510M 3520M 3530M 3540M 3550M

D D

G/H

Regular

1.0 2.0 3.0 4.0 5.0

1.5mm G/H Fixture level

3.7mm

4010S 4020S 4030S 4040S 4050S

• Order

code : HGLCA + item code ex) HGLCA + 4010S = HGLCA4010S • Used for making implant retained overdentures • Accommodates up to 40° divergence between two implants • Stable dual retention and optimal holding capabilities against various retention forces (6N, 12N, 22N) • Use LOCATOR® torque driver • Tightening torque : 30Ncm

D

LOCATOR® Male Processing Kit

LOCATOR® male processing kit

LMPS

• Includes

denture cap, block-out spacer, black processing male & replacement males (blue, pink, clear) • packaging: 2 units

LOCATOR® Replacement Male

6N

12N

22N

Retention force 6N

LRM06S

12N

LRM12S

22N

LRM22S

• packaging:

17

ETIII SA Implant System Catalog

4 units

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 20

6N

Prosthetic Components

LOCATOR® Extended Replacement Male

Retention force

12N • Used

6N

LEM06S

12N

LEM12S

for implant divergences between 10* to 20* 4 units

• packaging:

LOCATOR® Black Processing Male

LOCATOR® black processing male • Used

for laboratory production

• packaging:

LOCATOR® Block-Out Spacers

4 units

LOCATOR® block-out spacers • Used

LBPS

LBSS

for block-out process 20 units

• packaging:

LOCATOR® Impression Coping

LOCATOR® impression coping • Used

LICS

for abutment level impression 4 units

• packaging:

LOCATOR® Lab Analog

Diameter 4.0

LAL40S

5.0

LAL50S

• Replicates • packaging: LAL40S

the abutment for use by the dental laboratory 4 units

LAL50S

Prosthetic Components

18

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 21

Stud Abutment & Components Stud Abutment Overdenture restoration

Mini

Regular

3.5mm

3.5mm

1.0

351M

351S

2.0

352M

352S

3.0

353M

353S

4.0

354M

354S

5.0

355M

355S

6.0

356M

356S

D

G/H

D

G/H Fixture Level

• Order

code : HGSAO + item code ex) HGSAO + 351M = HGSAO351M • Used for stud-type overdentures • Maximum path compensation of 20° • Use stud abutment driver • Tightening torque : 30Ncm  Retainer cap set & O-ring can be purchased separately

19

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 22

Retainer cap set

Prosthetic Components

Retainer Cap Set

OARCS

• Can

be used with two types of retention force retention force with solid denture placement  Includes retainer cap and O-rings (for laboratory, low retention and high retention)  O-ring can be purchased separately

• Excellent

Retainer Set

Retainer set

OARS

• More

effective for small, occlusual gaps as compared to retainer cap  Includes retainer + O-rings (for laboratory, low retention and high retention)  O-ring can be purchased separately

O-Ring Set

O-ring set (for laboratory)

OAO100S

• Used

for production of overdentures  Includes O-ring 5 piece

O-ring (for laboratory)

O-ring (Low retention)

O-ring set (Low retention)

OAO400S

• Oral

O-ring with low retention force (approximately 4N)  Includes O-ring 5 piece

O-ring (High retention)

O-ring set (High retention)

OAO600S

• Oral

O-ring with high retention force (approximately 6N)  Includes O-ring 5 piece

Stud Lab Analog

Stud lab analog

OAL

• Replicates

the implant for use by the dental laboratory to impression coping after the impression has been taken and fixed to the working model

• Locked

Prosthetic Components

20

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 23

Rigid Abutment Rigid Abutment Cement retained restoration

Mini

H

4.0mm

D

4.0 H

G/H Fixture Level

5.5

4.0

5.5

7.0 7.0

G/H

4.0mm

4.5mm

1.0

4014MP

4514MP

2.0

4024MP

4524MP

3.0

4034MP

4534MP

4.0

4044MP

4544MP

1.0

4015MP

4515MP

2.0

4025MP

4525MP

3.0

4035MP

4535MP

4.0

4045MP

4545MP

1.0

4017MP

4517MP

2.0

4027MP

4527MP

3.0

4037MP

4537MP

4.0

4047MP

4547MP

4.5mm • Order

D

H

G/H Fixture Level

4.0

21

5.5

7.0

ETIII SA Implant System Catalog

code : HGRGA + item code ex) HGRGA + 4014MP = HGRGA4014MP • Used for making general cement-type prosthesis • Combined abutment and screw • 11° taper connection for enhanced safety • Gingival gold color for improved esthetics • Cross-section design to minimize prosthesis rotation • 4.0mm : use outer driver 4.5mm/ 5.0mm/ 6.0mm : use outer driver and 1.2 hex driver 7.0mm : Use 1.2 hex driver • Tightening torque : 30Ncm  Includes protection cap (can be purchased separately)

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 24

Prosthetic Components

Rigid Abutment Cement retained restoration

Regular

H

D

4.0mm H

4.0 G/H Fixture Level

4.0

5.5

7.0 5.5

D

4.5mm H

G/H

7.0

Fixture Level

4.0

5.5

H

5.0mm H

4.0

G/H

5.5

7.0

5.5

D

6.0mm H

G/H

4.0

4.0mm

4.5mm

5.0mm

1.0

4014SP

4514SP

5014SP

2.0

4024SP

4524SP

5024SP

3.0

4034SP

4534SP

5034SP

4.0

4044SP

4544SP

5044SP

5.0

-

-

5054SP

1.0

4015SP

4515SP

5015SP

2.0

4025SP

4525SP

5025SP

3.0

4035SP

4535SP

5035SP

4.0

4045SP

4545SP

5045SP

5.0

-

-

5055SP

1.0

4017SP

4517SP

5017SP

2.0

4027SP

4527SP

5027SP

3.0

4037SP

4537SP

5037SP

4.0

4047SP

4547SP

5047SP

5.0

-

-

5057SP

7.0 D

4.0

D

G/H

5.5

7.0

D

7.0

D

6.0mm

7.0mm

1.0

6014SP

-

2.0

6024SP

-

3.0

6034SP

-

4.0

6044SP

-

5.0

6054SP

-

1.0

6015SP

7015SP

2.0

6025SP

7025SP

3.0

6035SP

7035SP

4.0

6045SP

7045SP

5.0

6055SP

7055SP

1.0

6017SP

-

2.0

6027SP

-

3.0

6037SP

-

4.0

6047SP

-

5.0

6057SP

-

G/H

• Order

code : HGRGA+ item code ex) HGRGA + 4014SP = HGRGA4014SP

7.0mm H G/H

5.5

Prosthetic Components

22

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 25

Rigid Abutment Components Rigid Protection Cap

Mini / Regular D

4.0mm

4.5mm

4.0

4004

4504

5.5

4005

4505

7.0

4007

4507

H

D

H

Regular H:4.0

H:5.5

D

5.0mm

6.0mm

4.0

5004S

6004S

-

5.5

5005S

6005S

7005S

7.0

5007S

6007S

-

H

H:7.0

7.0mm

• Order

code : HGRPC + item code ex) HGRPC + 4004 = HGRPC4004 • Protects abutment and minimizes patient's discomfort • Applicable as a substructure for temporary prosthesis • Conveniently locks in place

Rigid Impression Coping

Mini / Regular D

4.0mm

4.5mm

4.0(Yellow)

4004S

4504S

5.5(Gray)

4005S

4505S

7.0(Blue)

4007S

4507S

H

Regular D

5.0mm

6.0mm

7.0mm

4.0(Yellow)

5004SS

6004SS

-

5.5(Gray)

5005SS

6005SS

7005SS

7.0(Blue)

5007SS

6007SS

-

H D

H:4.0

H:5.5

H:7.0

• Order

code : HGRIC + item code ex) HGRIC + 4004S = HGRIC4004S • Used for taking impressions of rigid abutment • Color provides easy identification of abutment size - 4mm(Yellow), 5.5mm(Gray), 7.0mm(Blue) • Conveniently locks in place

23

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 26

Prosthetic Components

Rigid Burn-Out Cylinder

Mini / Regular Type

D

4.0mm

4.5mm

Single

40S

45S

Bridge

40B

45B Regular

D

5.0mm

6.0mm

Single

50SS

60SS

70SS

Bridge

50SB

60SB

70SB

Type D

(Single)

(Bridge)

7.0mm

• Order

code : HGRBC + item code ex) HGRBC + 40S = HGRBC40S • Used as prosthetic framework by connecting to rigid lab analog • Color provides identification of case type: Single (red), Bridge (white) • After prosthetic casting, the margin may be adjusted by a specialpurpose reamer

a. Snapped on the shoulder due to the burnout cylinder’s elasticity before casting b. Unfit due to metal inelasticity after casting c. Fit after reaming using a reamer

Rigid Lab Analog

Mini / Regular D

4.0mm

4.5mm

4.0(Yellow)

4004

4504

5.5(Gray)

4005

4505

7.0(Blue)

4007

4507

H

D

H

Regular D

5.0mm

6.0mm

7.0mm

4.0(Yellow)

5004S

6004S

-

5.5(Gray)

5005S

6005S

7005S

7.0(Blue)

5007S

6007S

-

H

H : 4.0

H : 5.5

H : 7.0

• Order

code : HGRLA + item code ex) HGRLA + 4004 = HGRLA4004 • Create rigid abutment on a working model • Color provides identification of abutments of varying lengths - 4mm(yellow), 5.5mm(gray), 7.0mm(blue)

Prosthetic Components

24

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 27

Angled Abutment

Angled Abutment

G/H

Cement retained restoration

Mini 1.2

4.3mm

D

Hex(A Type)

432MAW

2.0

Hex(B Type)

432MBW

Non-Hex

432MNW

4.0

Hex(A Type) Hex(B Type) Non-Hex

434MAW 434MBW 434MNW

4.3mm 17°

Type

G/H Fixture Level D

30°

( A type ) ( B type )

( Non-Hex )

Regular

G/H

4.5mm

Type

D

Hex(A Type) 1.2

2.0

4.0

4.5mm

5.5mm

452SAW

552SAW

Hex(B Type)

452SBW

552SBW

Non-Hex

452SNW

552SNW

Hex(A Type)

454SAW

554SAW

Hex(B Type)

454SBW

554SBW

Non-Hex

454SNW

554SNW

G/H

• Order

D

( A type ) ( B type )

( Non-Hex )

5.5mm 1.2

G/H

D

( A type )

25

( B type )

( Non-Hex )

ETIII SA Implant System Catalog

code : HGAGA + item code ex) HGAGA + 432MAW = HGAGA432MAW • Used for the path adjustment of prosthesis at 17° axial angle • 11° taper connection for excellent safety • Gold color for improved esthetics • Functions as a double hex type (A and B hex types) • Abutment selector enables the selection of precise hex-type abutments • Use 1.2 hex driver • Tightening torque : 20Ncm (mini), 30Ncm (Regular)  Includes Ebony Gold abutment screw  Ebony Gold abutment screw can be purchased separately (Mini : HGATSM, Regular : HGATSS)

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 28

Prosthetic Components

Angled Abutment Selector

Mini G/H 2.0 4.0

Regular

4.3mm

4.5mm

5.5mm

Hex(A Type)

432MA

452SA

552SA

Hex(B Type)

432MB

452SB

552SB

Hex(A Type)

434MA

454SA

554SA

Hex(B Type)

434MB

454SB

554SB

D

Type

• Order code : HGAAS + item code ex) HGAAS + 432MA = HGAAS432MA • Used for the selection of specifications such as A- or B-type Angled abutments, diameter, and G/H in the oral cavity or on a working model

Use of Angled Abutment Selector There are A/B two types of Angled Abutments. The internal hex structure of the fixture can cause interference between the 17° tapered body angled abutment and adjacent teeth. Choose an appropriate A/B Hex type using an angled abutment selector to minimize abutment reduction before prosthesis fabrication. Hex A Type

Hex B Type

Non-Hex

Hex A Type

Hex B Type

Selection Tools

A type selector connection

B type selector connection

(proper)

(improper)

Prosthetic Components

26

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 29

ZioCera Abutment ZioCera Abutment Cement or screw retained restoration

Mini

4.5mm

D

4.5mm

H 1.2

Type

Hex

Non-Hex

3.5

453MHW

453MNW

5.0

455MHW

455MNW

G/H

7.0 H

G/H

Fixture Level D

Hex

Non-Hex

Regular

4.5mm

D

4.5mm

H

Type

Hex

Non-Hex

3.5

453SHW

453SNW

5.0

455SHW

455SNW

G/H

1.2

7.0 H

5.5mm

D G/H

H

Fixture Level D

Non-Hex

Hex

Non-Hex

3.5

553SHW

553SNW

5.0

555SHW

555SNW

G/H

7.0

Hex

Type

6.5mm

D H

5.5mm 1.2

7.0

Type

Hex

Non-Hex

3.5

653SHW

653SNW

5.0

655SHW

655SNW

G/H

H

• Order G/H

Fixture Level D

Hex

Non-Hex

6.5mm 1.2

H

G/H

Fixture Level D

Hex

27

Non-Hex

ETIII SA Implant System Catalog

code : HGZCA + item code ex) HGZCA + 453SHW = HGZCA453SHW • Used with esthetic prosthesis (Zirconia) • Ivory color mimics a natural tooth • The use of direct build-up method allows improved screw rotation • Use 1.2 hex driver • Tightening torque : 20Ncm (Mini), 30Ncm (Regular)  Includes Ebony Gold abutment screw  Ebony Gold abutment screw can be purchased separately (Mini : HGABSM, Regular : HGABSS)

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 30

Prosthetic Components

ZioCera Angled Abutment Cement or screw retained restoration

Standard H 5.5mm

6.5mm

17°

Hex

Non-Hex

3.0

553SHW

553SNW

4.0

-

6.5mm

D H

G/H

Type

G/H

9.0

H

1.2

Fixture Level

5.5mm

D

9.0

Type

G/H

Hex

Non-Hex

3.0

-

-

4.0

654SHW

654SNW

D

Hex

Non-Hex

• Order code : HGZAA + item code ex) HGZAA + 553SHW = HGZAA553SHW • Used for the aesthetic prosthesis (Zirconia) • Ivory color like a natural tooth • The use of direct build-up method enables the screw restoration • The diameter which is useful and margin forms which are possible to modify • Used for the path adjustment of anterior in case of 17° axial angle • Use the 1.2 hex driver • Tightening torque : 30Ncm (Standard) ※ Includes EbonyGold abutment screw (may purchased separately. Mini : HGABSM, Standard : HGABSS)

Prosthetic Components

28

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 31

FreeForm ST Abutment FreeForm ST Abutment

G/H 1.5

Mini

3.0 1.2

D

Type

Cement retained restoration

4.0mm

Hex

401MHW

Non-Hex

401MNW

Hex

403MHW

Non-Hex

403MNW

(4.0mm)

G/H Fixture Level D

Hex

Non-Hex

Regular

G/H

(4.0mm)

1.5

(5.5mm) 1.2

3.0

4.0mm

5.5mm

7.0mm

Hex

401SHW

551SHW

701SHW

Non-Hex

401SNW

551SNW

701SNW

Hex

403SHW

553SHW

703SHW

Non-Hex

403SNW

553SNW

703SNW

D

Type

• Order

G/H

D

Hex

Non-Hex

Hex

Non-Hex

(7.0mm)

code : HGFSA + item code ex) HGFSA + 401MHW = HGFSA401MHW • Used to adjust the path of abutment and customize prosthetic margin • 11° taper connection for enhanced safety • Gingival gold color for improved esthetics • Use 1.2 hex driver • Tightening torque : 20Ncm (mini), 30Ncm (Regular)  Includes Ebony Gold abutment screw  Ebony Gold abutment screw can be purchased separately (Mini : HGATSM, Regular : HGATSS)

1.2

When modifying Freeform ST abutment, the minimum length of the abutment after modification cannot be less than 4mm from the margin to the top of the abutment G/H

D

Hex

29

Non-Hex

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:48 AM Page 32

Convertible Abutment

Screw & Cement Retained Restoration

Mini D

G/H

1.0

GSCA4010P

2.0

GSCA4020P

3.0

GSCA4030P

4.0

GSCA4040P D

4.0mm

4.8mm

6.0mm

1.0

GSCAS4010P

GSCA4810P

GSCA6010P

2.0

GSCAS4020P

GSCA4820P

GSCA6020P

3.0

GSCAS4030P

GSCA4830P

GSCA6030P

4.0

GSCAS4040P

GSCA4840P

GSCA6040P

5.0

-

GSCA4850P

GSCA6050P

G/H

Fixture Level

Regular

4.0mm

D

G/H

Prosthetic Components

Convertible Abutment

• Used

D

for creating bridges with dislocated path to switch prosthesis onto a cylinder following abutment connection in the oral cavity • 4.0mm : Used with O-ring abutment driver 4.8mm, 6.0mm : Used with Octa abutment driver • Tightening torque : 30 Ncm  Includes Carrier • Designed

G/H

Convertible Combination Cylinder

Mini H

D 1.2

7.0

Regular

4.0mm

4.0mm

4070WH(Hex) 4070NWH(Non-Hex)

Ebony Gold Screw

GSFSM

4.8mm

6.0mm

4870WH (Octa)

6070WH (Octa)

GSFSR

H

• Order D

code : GSCC + item code ex) GSCC + 4870WH = GSCC4870WH • Used for making combination-retained prosthesis using convertible abutments. • Use 1.2 hex driver • Tightening torque : 20 Ncm  Includes Ebony Gold Cylinder Screw

Prosthetic Components

30

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 33

Convertible Abutment Components Convertible GoldCast Cylinder

Mini D

H

4.0mm

400WH(Hex)

12

400NWH(Non-Hex)

1.2

Ebony Gold Screw H

Regular

4.0mm

4.8mm

6.0mm

480WH (Octa)

600WH (Octa)

GSFSM

GSFSR

• Order

code : GSGC + item code ex) GSGC + 480WH = GSGC480WH • Used for making screw-retained prosthesis using convertible abutments • Dental gold alloy should be used to cast the prosthesis • Melting point range of cylinder (Au, Pt, Pd Alloy) : 1400°c- 1450°c (use of non-precious metal alloy for casting prohibited) • Use 1.2 hex driver • Tightening torque : 20 Ncm  Includes Ebony Gold Cylinder Screw

D

Convertible Temporary Cylinder

Mini D

H

4.0mm

400WHW(Hex)

10

1.2

Regular

4.0mm

400NWH(Non-Hex)

4.8mm

6.0mm

480WH (Octa)

600WH (Octa)

GSFSM

Ebony Gold Screw

GSFSR

H

• Order

code : GSCTC + item code ex) GSCTC + 480WH = GSCTC480WH • Used to make temporary prosthesis • Easy to customize; for a large range of cases • Use 1.2 hex driver • Tightening torque : 20 Ncm  Includes Ebony Gold Cylinder Screw

D

Convertible Plastic Cylinder

Mini D

H

12 1.2

EbonyGold Screw H

D

31

ETIII SA Implant System Catalog

Regular

Ø4.0

Ø4.0

400WH(Hex) 400NWH(Non-Hex) GSFSM

• Order code : GSCPL + item code ex) GSCPL + 480WH = GSCPL480WH • Used to make temporary prosthesis • Easy to customize; for a large range of cases • Use a 1.2 hex driver • Tightening torque: 20Ncm

Ø4.8

Ø6.0

480WH (Octa)

600WH (Octa)

GSFSR

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 34

Mini D

Regular

4.0mm

4.0mm 400

Code

Prosthetic Components

Convertible Pick-up Impression Coping

4.8mm

6.0mm

480

600

H

• Order

D

code : GSPIC + item code ex) GSPIC + 480 = GSPIC480 • Pick-up type for taking an impression using a customized tray • Impression coping designed with Hole-in-one ; no need for resin fixation • Asymmetrical structure minimizing contact interference ( )  Includes Guide Pin

Convertible Transfer Impression Coping

Mini D

Regular

4.0mm

Code

4.0mm 400

4.8mm

6.0mm

480

600

• Order

code : GSTIC + item code ex) GSTIC + 480 = GSTIC480 • Used for taking an impression with a ready-made tray  Includes Guide Pin D

Prosthetic Components

32

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 35

Convertible Abutment Components Convertible Protection Cap

Mini D 1.2

Regular

4.0mm

4.0mm

Code

400WH

EbonyGold Screw

GSFSM

4.8mm

6.0mm

480WH

600WH

GSFSR

• Order

code : GSCHC + item code ex) GSCHC + 480WH = GSCHC480WH • Used for protection of convertible abutments and to minimize patient discomfort • Use 1.2 hex driver • Tightening torque : 20Ncm  Includes Ebony Gold Cylinder Screw

D

Convertible Lab Analog

Mini D Code

Regular

4.0mm

4.0mm

4.8mm

6.0mm

480

600

400

D

• Order

code : GSCLA+ item code ex) GSCLA + 480 = GSCLA480 • Used to create esthetic oral abutments on working models

Convertible Polishing Protector

Mini

D

Regular

D

4.0mm

4.8mm

6.0mm

Code

400

480

600

• Order

code : GSCPC + item code ex) GSCPC + 480 = GSCPC480 • Used for polishing prosthetic casting, to avoid damaging the cylinder joint

33

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 36

Multi Angled Abutment

Mini

D

Regular 17°

17° G/H

Angled

17°

30°

Fixture Level

30°

30°

Prosthetic Components

Multi-Angled Abutment

Mini-4.8mm

Regular-4.8mm

2.5

217MHW

217SHW

3.0

317MHW

317SHW

4.0

417MHW

417SHW

3.5

330MHW

330SHW

4.0

430MHW

430SHW

5.0

530MHW

530SHW

G/H

• Used with esthetic low cylinders and components (non-hex only) • Connected to implant by multi-angled abutment carrier • Includes multi-angled abutment screw • Multi-angled carrier sold separately • Tightening torque : Mini - 20 Ncm, Regular - 30Ncm Order code Multi Angled Abutment package : HGMAA + item code

G/H Fixture Level

ex) HGMAA + 317MHW = HGMAA317MHW

Multi-Angled Abutment Screw EbonyGold Screw Mini 1.2

Mini

Regular

HGMATSM

HGMATSS

Regular 1.2

Multi-Angled Abutment Carrier

• Use a 1.2 hex driver • For multi-angled abutment only

Code

HGMAC

• Tool for stable & safety connect implant to multi-angled abutment

Prosthetic Components

34

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 37

Esthetic-Low Cylinders & Components Esthetic Low Transfer Impression Coping

H

D 8.0

4.8mm MTTR100

• For closed tray H

D

Esthetic Low Pick up Impression Coping

H

D 8.0 15

Guide pin (L)

4.8mm MSR100 GP150*

• Packing : Esthetic low pick-up impression coping + guide pin( GP150) L 8.0

D

Esthetic Low Lab Analog

Esthetic Low Healing Cap

Code

H

MERR300

D 4.6

4.8mm MHCR100

• Used during soft tissue healing period after the impression

Esthetic Low Cylinder Screw

Code • Use 1.2 hex driver

35

ETIII SA Implant System Catalog

MTS200

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 38

Type

D

Prosthetic Components

Esthetic Low Gold Cylinder

4.8mm

Non-Hex

MGR100WH

Ti Cylinder Screw

MTS200

• Used with precious alloy casting • Packaging: Esthetic low gold cylinder + Ti cylinder screw • Tightening torque : 20Ncm * Ti cylinder screw included * Ti cylinder screw can be purchased separately.

Esthetic Low Plastic Cylinder

Type

D

4.8mm

Non-Hex

MEPR100TH

Ti Cylinder Screw

MTS200

• Used with non-precious alloy casting • Packaging: Esthetic low plastic cylinder + Ti cylinder screw • Tightening torque : 20Ncm * Ti cylinder screw included * Ti cylinder screw can also be purchased separately.

Esthetic Low Temporary Cylinder

Type

D

4.8mm

Non-Hex

MTR100TH

Ti Cylinder Screw

MTS200

• For provisional restorations • Packaging: Esthetic low temporary cylinder + Ti cylinder screw • Tightening torque : 20Ncm * Ti cylinder screw included * Ti cylinder screw can be purchased separately.

Esthetic Low Polishing Protector

H

D 4.6

4.8mm MPCR100

• Use a polishing work after Casting or making provisional restorations

Prosthetic Components

36

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 39

Abutment Screw Abutment Screw Ebony Gold Abutment Screw Mini 1.2

Regular

Mini

HGABSM

1.2

Regular

HGABSS

• Use

1.2 hex driver Gold abutment screw can be purchased separately • Applicable abutments - ZioCera abutment • Ebony

Old Style

Old Style

1.2

1.2

Mini

HGATSM

Regular

HGATSS

• Use

1.2 hex driver Gold abutment screw can be purchased separately • Applicable abutments - Transfer abutment - Angled abutment - FreeForm ST abutment - GoldCast abutment • Ebony

New Style

New Style

Titanium Abutment Screw Mini

Regular

Mini

HGABSMT

1.2

1.2

Regular

HGABSST

• Use

1.2 hex driver abutment screw can be purchased separately

• Titanium

Old Style

Old Style

1.2

1.2

Mini

HGATSMT

Regular

HGATSST

• Use

1.2 hex driver abutment screw can be purchased separately • Applicable abutments - Temporary abutment • Titanium

New Style

37

New Style

ETIII SA Implant System Catalog

ETIII and Prosthetics 40pp Dec2013_ETIII and Prosthetics 40pp Aug2013 12/18/13 11:49 AM Page 40

Code

Lab Screw 1.2

1.2

Mini

Regular

Lab Screw

HGATSML

HGATSSL

Waxing Screw

HGATSMW

HGATSSW

Prosthetic Components

Laboratory Screw

• Lab

Screw : Replaces abutment screw. Screw : Use for making the screw hole of a transfer jig or wax-up component. • Laboratory screw can be purchased separately • Applicable abutments - Transfer abutment - Angled abutment - FreeForm ST abutment - GoldCast abutment • Waxing

Waxing Screw 1.2

1.2

Prosthetic Components

38

Suggest Documents