EQN100 Mini Cube IP Camera

EQN100 Mini Cube IP Camera Auto White Balance, 3DNR User’s Manual Copyright © EverFocus Electronics Corp, Release Date: August, 2015 Copyright  1...
Author: Christian Park
9 downloads 2 Views 2MB Size
EQN100 Mini Cube IP Camera Auto White Balance, 3DNR

User’s Manual

Copyright © EverFocus Electronics Corp, Release Date: August, 2015

Copyright  1995-2015 EverFocus Electronics Corp. All rights reserved. No part of the contents of this manual may be reproduced or transmitted in any form or by any means without written permission of the EverFocus Electronics Corporation.

EverFocus 12F-1, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, New Taipei City, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 3943 www.everfocus.com.tw

August, 2015

About this document All the safety and operating instructions should be read and followed before the unit is operated. This manual should be retained for future reference. The information in this manual was current when published. The manufacturer reserves the right to revise and improve its products. All specifications are therefore subject to change without notice.

Regulatory Notices FCC Notice "Declaration of Conformity Information" This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help. Warning: Changes or modifications made to this equipment, not expressly approved by EverFocus or parties authorized by EverFocus could void the user's authority to operate the equipment. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. EverFocus Electronics Corp. 12F-1, No. 79, Sec. 1, Shin-Tai Wu Rd., Hsi-Chi, New Taipei City, Taiwan

i

Precautions 1. Do not install the camera near electric or magnetic fields. Install the camera away from TV/radio transmitters, magnets, electric motors, transformers and audio speakers since the electromagnetic fields generated from these devices may distort the video image or otherwise interfere with camera operation. 2. Never disassemble the camera beyond the recommendations in this manual nor introduce materials other than those recommended herein. Improper disassembly or introduction of corrosive materials may result in equipment failure or other damage. 3. Try to avoid facing the camera toward the sun. In some circumstances, direct sunlight may cause permanent damage to the sensor and/or internal circuits, as well as creating unbalanced illumination beyond the capability of the camera to compensate. 4. Keep the power cord away from water and other liquids and never touch the power cord with wet hands. Touching a wet power cord with your hands or touching the power cord with wet hands may result in electric shock. 5. Never install the camera in areas exposed to oil, gas or solvents. Oil, gas or solvents may result in equipment failure, electric shock or, in extreme cases, fire. 6. Cleaning For cameras with interchangeable lenses, do not touch the surface of the sensor directly with the hands. Use lens tissue or a cotton tipped applicator and ethanol to clean the sensor and the camera lens. Use a damp soft cloth to remove any dirt from the camera body. Please do not use complex solvents, corrosive or abrasive agents for cleaning of any part of the camera. 7. Do not operate the camera beyond the specified temperature, humidity or power source ratings. Use the camera at temperatures within 0°C ~ 50°C / 32°F~122°F (12 VDC), and humidity between 20% and 80%; this device is not rated as submersible. The input power source is 12 VDC. Be sure to connect the proper + / - polarity and voltage, as incorrect polarity or too high a voltage will likely cause the camera to fail, and such damage is not covered by the warranty. The use of properly fused or Class 2 power limited type supplies is highly recommended. 8. Mounting Use care in selecting a solid mounting surface which will support the weight of the camera plus any wind, snow, ice or other loading, and securely attach the camera to the mounting surface using screws and anchors which will properly support the camera. If necessary (e.g. when mounting to drop ceilings) use a safety wire to provide additional support for the camera.

ii

Table of Contents 1. 2. 3. 4.

5.

6. 7.

8. 9. 10.

Introduction ........................................................................................................... 1 Features .................................................................................................................. 1 Physical Description .............................................................................................. 2 3.1 Dimensions .................................................................................................................. 2 Installation ............................................................................................................. 3 4.1 Packing List .................................................................................................................. 3 4.2 Optional Accessory...................................................................................................... 3 4.3 Basic Installation.......................................................................................................... 3 Accessing the Camera ........................................................................................... 4 5.1 Checking the Dynamic IP Address ............................................................................... 4 5.2 Settings for Microsoft Internet Explorer ..................................................................... 6 5.3 Connecting the Camera to the Network ..................................................................... 8 5.4 Live View Window ..................................................................................................... 10 Playback ................................................................................................................ 11 System Settings.................................................................................................... 12 7.1 Local Config ............................................................................................................... 12 7.2 Video Settings............................................................................................................ 13 7.2.1 OSD Settings ....................................................................................................... 13 7.2.2 Video Coding ...................................................................................................... 14 7.2.3 Video Mask ......................................................................................................... 16 7.2.4 Video Parameter ................................................................................................ 17 7.3 Network Settings ....................................................................................................... 19 7.3.1 Basic Setting ....................................................................................................... 19 7.3.2 LAN Setting ......................................................................................................... 20 7.3.3 PPPoE Setting ..................................................................................................... 21 7.3.4 UPNP Setting ...................................................................................................... 22 7.3.5 Email Setting....................................................................................................... 23 7.3.6 FTP Setting.......................................................................................................... 24 7.3.7 DDNS Setting ...................................................................................................... 25 7.3.8 VPN Setting......................................................................................................... 26 7.3.9 RTSP Setting........................................................................................................ 27 7.3.10 IP Email ........................................................................................................ 28 7.3.11 Connect Setting ........................................................................................... 29 7.4 Alarm Settings ........................................................................................................... 30 7.4.1 Motion Detection ............................................................................................... 30 7.5 System Setting ........................................................................................................... 32 7.5.1 System Info ......................................................................................................... 32 7.5.2 System Time ....................................................................................................... 33 7.5.3 User Manage ...................................................................................................... 34 7.5.4 Upgrade .............................................................................................................. 35 7.5.5 Restore ............................................................................................................... 36 7.5.6 Restart ................................................................................................................ 36 7.5.7 System log .......................................................................................................... 37 Alarm Search ........................................................................................................ 38 Specifications ....................................................................................................... 39 Appendix ............................................................................................................... 40 Appendix 1 Network Interface of IP Camera ..................................................................................... 40 Appendix 2 Default Network Parameters ............................................................................... 40 iii

EQN100

1. Introduction The EQN100 mini cube IP camera comes with 1.3MP image quality, providing up to 30fps at 1280 x 1024 viewing resolution. The camera supports dual streams from H.264 and MJPEG compression formats. High performance 3DNR noise reduction and auto wide balance functions are also supported. Since EQN100 conforms to ONVIF for compatibility with other network video devices, it interoperates with a wide variety of hardware and software systems. You can also use EverFocus Mobile Applications to remotely view the live views of the cameras through your handheld devices. The camera can be powered by 12VDC power supply. The tiny design makes it is easy to be installed and operate. The EQN100 is suitable for small and medium-sized environments.

System Requirement Before installing, please check that your computer supports Microsoft Windows XP/2003/Win7/Vista.

2. Features •

1/3” progressive CMOS image sensor delivers 1.3MP resolution



High performance noise reduction function



Multi-streaming from H.264 / MJPEG



Power supply by 12 VDC



Supports live monitoring of video from mobile devices via MobileFocus / MobileFocus Plus apps (iOS and Android)



ONVIF compliant

1

EQN100

3. Physical Description Front View

Rear View Cable

2

1

3

4

No. Item Name

Descriptions

1

Lens

Fix focal lens 6mm (optional:2.8mm, 3.6mm, 8mm)

2

Reset Button

Use a paper click to press and hold the Reset Button for 2 seconds and then release the button for 2 seconds. Repeat doing this 3 times to reset all configurations to factory default setting.

3

LAN Cable

Connects to a router.

4

Power Cable

Connects to a 12VDC power source.

3.1

Dimensions

2

EQN100

4. Installation 4.1

Packing List

Please check that there is no missing item in the package before installing. •

Camera x 1



Quick Installation Guide x 1

Note:

1. Equipment configurations and supplied accessories vary by country. Please consult your local EverFocus office or agents for more information. Please also keep the shipping carton for possible future use. 2. Contact the shipper if any items appear to have been damaged in the shipping process. 4.2

Optional Accessory

You can use the optional accessory to expand the capabilities and versatility of the camera. Please contact your dealer for more information. • IP Sidekick - ESK1000

• Bracket - BA-EQN

Using it for installation, you do not need to pre-configure the IP address or to use an additional monitor to check and adjust all the IP cameras. The product can assign an IP address to the camera, and then you can connect and check the camera live view using our mobile app EF Sidekick. For details about IP Sidekick, please refer to the IP Sidekick – ESK1000 User’s Manual. You can use the bracket to install EQN100 onto the desired surface. *Two M3*5 screws and two washers are included for screwing the camera to bracket.

4.3

Basic Installation

To install this IP camera, you have to prepare 4 screws (M3 with max length of 2mm) and then screw the camera to the installation surface. The four screw holes on the camera are illustrated below (top / bottom / left / right). Please be noted the Top screw hole should face up in order to display correct camera view position. Top

3

EQN100

5. Accessing the Camera This section explains how to access the Web interface of the camera for configuration.

5.1

Checking the Dynamic IP Address

You can look up the IP address and access the Web interface of the camera using the IP Utility software, which can be downloaded from EverFocus’ Website (Download Center) (http://www.everfocus.com.tw/HQ/Support/DownloadCenter_p1.aspx). Please connect the IP camera on the same LAN of your computer. 1.

Extract the files after downloading the IP Utility to your computer. Double click the IP Utility Setup.exe and follow the on-screen instructions to install the IP Utility.

2.

Click the Finish button, the IP Utility will be automatically launched to search the IP devices connected on the same LAN.

4

EQN100 3.

To access the Live View window, double click the IP address of the device, the login window appears.

4.

Download and install the ActiveX file by clicking File on the login window. Click Run and follow the instructions to install the program. Click Finish to complete the process.

5.

On the login window, type the user ID and password to log in. By default, the user ID is user1 and the password is 11111111. Click Login, the Live View window appears.

Note: Before start operating the IP camera, please make sure the camera date and time are correct. To configure the camera date/time, go to Config > System > System Time on the Web UI.

5

EQN100 5.2

Settings for Microsoft Internet Explorer

To enable Remote Live View, Firmware Upgrade and ActiveX Prompt on Internet Explorer, some settings have to be complete. Please follow the steps below: 1.

On the computer, click Start > Control Panel > System and Security > Action Center (click Change User Account Control Settings), the User Account Control Settings window appears. Adjust the slide bar to Never Notify and then click OK. Restart your computer if requested.

2.

Open the Internet Explore, click Tools > Internet Options > Security Tab > Custom Level, the Security Settings windows appears.

6

EQN100 3.

In the Download unsigned ActiveX controls field, select Prompt. In the Include local directory path when uploading files to a server field, select Enable. Click OK.

4.

In the Internet Options window, click the Advanced tab and then disable Enable memory protection to help mitigate online attacks. Click OK.

7

EQN100 5.3

Connecting the Camera to the Network

There are three methods to connect the IP camera to the network: Router or LAN Connection, Direct High-Speed Connection and One-to-One Connection. Router or LAN connection This is the most common connection in which the IP camera is connected to a router and allows multiple users on and off site to see the IP camera on a LAN/WAN (Internet). The camera must be assigned an IP address that is compatible with its LAN. By setting up port forwarding on the router, you can remotely access the cameras from outside of the LAN via the Internet. To remotely access the Web interface of the IP camera, please refer to 7.3.7 DDNS Settings. To set up port forwarding, please consult the manual of the router. Cat 5 Straight Through Cable Internet

High-speed modem Straight-through LAN patch cable

Router

Left: Pinout of a straight-through cable.

Direct High-Speed Connection In a Direct High-Speed Connection, the camera connects directly to a modem without the need for a router. You need to set the static or dynamic WAN IP address assigned by your ISP (Internet Service Provider) in the camera’s configuration web pages. To access the camera, just type “http://xxx.xxx.xxx.xxx”, where xxx.xxx.xxx.xxx is the IP address given by your ISP. If you have a dynamic IP address, this connection may require that you use DDNS for a reliable connection. Please refer to 7.3.7 DDNS Settings. Internet

Cat 5 Straight Through Cable

8

High-speed modem

EQN100 One-to-One Connection (Directly from PC to IP Camera) You can connect directly without using a switch, router or modem. However, only the PC connected to the camera will be able to view the IP camera. You will also have to manually assign a compatible IP address to both the computer and the IP camera. Unless the PC has another network connection, the IP camera will be the only network device visible to the PC. See the diagram below:

Cat 5

Right: Pinout of a crossed-over cable.

9

EQN100 5.4

Live View Window

After logging in, the Live View window appears. On the Live view window, users can do operations like taking Snapshot, Recording, Alarm Search, Playback and Full-screen Viewing.

[Liveview] Click to enter the Live View window. [Replay] Click to enter the Playback page, please refer to 6. Playback. [Config] Click to enter the System Settings page, please refer to 7. System Settings. [Alarm] Click to enter the alarm search page, please refer 8. Alarm Search. [Log out] Click to log out the system. [Main Stream] Call the main stream of camera to get the best quality. To set up the main stream parameters, please refer to 7.2.2 Video Coding. [Sub Stream] Call the sub stream of camera, with low resolution, suit for bad network or Internet. To set up the sub stream parameters, please refer to 7.2.2 Video Coding. [Snap]: Click “Snap”, snap the current image and save it in .JPG format automatically to the storage directory of snapped images. To change the storage path, please refer to 7.1 Local Config. [Record]: Click to start recording the current live view videos to your computer in H.264 format. To change the storage path or set up the packing time of the recordings, please refer to 7.1 Local Config. You can play back the recordings using the internal player, please refer to 6. Playback. Displayed status after recording starts: [Full]: Display images in full-screen, right click or press the Esc key on the keyboard to exit full screen mode. [W:H]: Click “W:H” to get the real W:H ratio of image, avoid image distortion when stretch to the size of screen. [Image]: Click Image, allow users to adjust Brightness, Contrast, Hue and Saturation of image.

10

EQN100

6. Playback After recording the camera live view to the computer, you can use this internal player to play back the recordings. To record camera live view, click the Record button on the Live View Window (see 5.4 Live View Window). Click to enter the video playback page. Users can search for recorded image files or snapped pictures in local PC or storage device according to date.

[Image]: Select a display ratio from the drop-down. [Storage]: Select PC to search a snapshot or recording from the computer. [Type]: Select a recording type from the drop-down. Manual Record: video recordings; Picture: snapshot images. [Date]: Select a specific date. [Search]: Click to start searching for the recordings/snapshot according to the setup attribute above. The searched data will be listed in the File List below. [Play]: Select a file in the File List by clicking on it, and the click the Play button to start displaying the snapshot or playback the recording. You can also use the tool bar above to play back the recordings.

11

EQN100

7. System Settings On the Live View window, click Config to enter the System Settings page.

7.1

Local Config

[Preview mode]: Users can choose Real time priority or Fluency priority mode according to their needs. [Reset Mosaic]: Select this option to make image quality better, but CPU usage rate will be higher at the same time. [Record file packing time]: Set packing time of record files for local PC when it is recording. [Record file path]: Set the storage directory for local records and snapped files. After you set these parameters, please click

to make them valid.

12

EQN100 7.2

Video Settings

7.2.1 OSD Settings You can configure the texts displaying on the live view streams.

[Title]: The name of video channel, displayed at the bottom left of image (movable), maximum characters allowed: 32. [Color]: You can choose different colors for the text. [Title]: Check the box to enable displaying title on live view stream. You can adjust the position for the title by using the direction buttons.

[Date/Time/Week]: Check the boxes to enable displaying Date, Time, Week on live view stream. You can adjust the display position by using the direction buttons. [Date Format]: Select a date format from the drop-down list. [Frame/Bitrate]: Check the box to enable displaying frame rate and bit rate on live view stream. [Connecting No.]: Check the box to enable displaying the number of connections to this camera. The number will be displayed at the end of title. For example, EverFocus EQN100(3). The “(3)” indicates there are 3 connections to this camera.

After you set these parameters, please click

to make them valid.

13

EQN100 7.2.2 Video Coding You can configure Main / Sub stream settings on this page.

[Coding Level]: Baseline and Main profile available, only for H.264 compression format. Baseline suits for low delay, and the situation have requirement on real time. Main profile suits for better quality. [Coding]: H.264 and M-JPEG. [Resolution]: Set resolution of images. [Quality]: You can choose the right quality according to your need: Fine, Normal, Basic, and the parameters can also be user-defined by choosing [Advanced]. When Advanced is selected, some settings will be grayed-out. [Advanced]: Check the box to enable advanced settings for Main stream. You can further setup the following settings. [Rate control]: This function is only available when Advanced is enabled. CBR adopts constant encoding bitrate, VBR adopts variable encoding bitrate. [Bitrate fluctuate]: Under CBR setting: set the bitrate range. You can choose self-adaption, it means the bitrate controlled by the software, and also can choose ±10%~±50%, ±10% means the bitrate range from -10% to +10% of the value of bitrate. Under VBR setting: set image quality from best to worst. [Bitrate]: The range of preferred and alternate stream is 30~16384Kbps. Higher bitrate setting can generate better image quality, but it occupies more bandwidth, please adjust the setting according to your actual bandwidth. Under CBR setting, [Bitrate] is the constant bitrate of encoding. Under VBR setting, [Bitrate] is the variable bitrate of encoding.

14

EQN100 [Frame rate]: Set encoding frame rate per second. Under poor network condition, frame rate can be reduced to control encoding bitrate to make motion images flow more smoothly. [GOP]: Adjustable between 1~200(Preferred Stream), 1~200(Alternate Stream). Smaller I frame interval means higher bitrate and better image quality. It is recommended to set the I frame interval as above 25. [LAN default value]: Click to return the LAN settings to factory default. Main stream: H.264 Coding, GOP: 75, frame rate: 25, rate control: VBR, image quality: better 720P:2048kps, 1080P:4096kps MJEPG Coding: GOP: 75, frame rate: 25, rate control: VBR, image quality: better 720P:9216kbps, 1080P:10240kbps Sub Stream: H.264 Coding: GOP: 50, frame rate: 25, bitrate: VBR, 512kbps, image quality: Bad MJPGE Coding: GOP: 50, frame rate: 25, bitrate: VBR, 4096kbps, image quality: Bad [WAN default value]: Click to return the WAN settings to factory default. H.264 Coding: GOP: 25, frame rate: 5, bitrate: CBR, 384kbps, image quality: Bad MJPEG Coding: GOP: 25, frame rate: 5, bitrate: CBR, 4096kbps, image quality: Bad

After you set these parameters, please click to make them valid (After change the coding level, resolution and coding, device will restart.). Note: Non-professional users please use “Advanced Settings” with caution.

15

EQN100 7.2.3 Video Mask The Video Mask can block out sensitive areas from view, covering the areas with black boxes in both live view and recorded clips. This feature is useful when users’ don’t want the sensitive information visible. Up to four Video Masks can be configured.

To set up a Video Mask: 1. 2.

Check the box of Enable Mask and then click the Mask area set button. Use your mouse to draw a rectangle area on the screen. Up to four rectangle areas can be set up. You can also click All to set up the entire stream for video mask.

3. 4.

Click Save, the configured areas will be applied with black masks. To clear mask areas, click Clear and then click the Save button.

16

EQN100 7.2.4 Video Parameter You can adjust video parameter on this page. Click Image, Basic and Advanced to configure the settings.

[Image]: You can adjust the following image color settings. Slide the bar to adjust the Brightness, Contrast, Hue, Saturation, Acutance, Gamma of video. Image:Select an image mode from Transparent or True Color. Click

to save the settings.

[Basic] Mirror: Set mirror, horizontally rotate the video. Flip: Set flip, vertically rotate the video. LSC: Enable or disable the Lens Shading Correction function. CTB: Set CTB, IPC will automatically turns on D/N function according to the image’s situation. 17

EQN100 WDR: Set WDR, enhance the image quality in such area: strong light source (sunlight, lamps or reflectors, etc.), shadow of high-brightness, backlight. 3D-DNR: Set 3D NR to get a clearer picture in low light environment, effectively eliminate video noise and color noise in low light conditions. Video Standard: In indoor environment, if the flashing of lamps results in the flickering of images, please choose 50HZ or 60HZ according to the power frequency. 50HZ suits for PAL system, 60HZ suits for NTSC system.

Click

to save the settings.

[Advanced] Gain Value: Change the value of AGC can adjust the effect of image in low light-level. Exposure Time: Set the value of Shutter to control exposure time. WB: You can choose Manual WB or AWB mode to adjust white balance, AWB is default open. AntiFogging: Set anti fogging function, when the density of fog up to a high value, the ISP will change the brightness and contrast to improve the quality of image. AntiFalseColor: Set anti false color function, can cancel the Moore profile effect in high frequency part. AntiTrembling: Click Close to disable or Open to enable the anti trembling function.

After you set these parameters, please click

to make them valid.

18

EQN100 7.3

Network Settings

7.3.1 Basic Setting

[Data Port]: Default value is 5000 (users are recommended not to change it). [Web Port]: Default value is 80 (users are recommended not to change it). [ONVIF Port]: Default value is 2000 (users are recommended not to change it). After you set these parameters, please click make the parameters valid.

19

and the device will reboot to

EQN100 7.3.2 LAN Setting

[DHCP Enable]: If DHCP function of the router is enabled, IP camera will automatically fetch IP address from the router. [IP]: Set the camera’s IP address. [Subnet Mask]: Default value is 255.255.255.0 (users are recommended not to change it). [Gateway]: Set the gateway IP of IP camera, for example when the device is connected to public network via a router, the gateway IP is the router IP. [Preferred DNS]: Enter the IP address of the DNS server if this is provided by an ISP. [Alternate DNS]: If your ISP provided you with a secondary DNS address, please enter it here. [MAC]: The Physical address of IP camera (users are recommended not to change it). Note: After you revise and save parameters, the device will restart. If it is applied in LAN, please pay attention to avoid IP collision.

20

EQN100 7.3.3 PPPoE Setting

[Enable]: Enable or disable PPPOE dial-up function. [IP]: After successful setting of device dial-up, it will display the public IP Address. [Username]: ADSL dial-up account, obtain from the IP service provider. [Password]: ADSL dial-up password, obtain from the IP service provider. [Online time]: Start timing after dial-up to see the online duration after successful dial-up.

After you set these parameters, please click

21

to make them valid.

EQN100 7.3.4 UPNP Setting Auto-mapping of port, when IP camera is connected to a router with UPNP function enabled, the router will automatically map the port in UPNP settings to public network, manual port mapping by users is not necessary.

[Network Card]: Select the type of NIC connecting UPNP router. [Mode]: Designate mode and auto mode. Designate mode means to specify data mapping port and web mapping port to router. Auto mode means data mapping port and web mapping port are set up by router. [Server URL]: Enter the IP address of the router with UPNP function. [Data Port Map No.]: Data mapping port of user-specified device on the router (works only under specified mode). [Web Port Map No.]: Web mapping port of user-specified device on the router (works only under specified mode). [Data Mapping Status]: When UPNP function runs successfully, the status bar will echo the data port mapped to the router by the device. [Web Mapping Status]: When UPNP function runs successfully, the status bar will echo the web port mapped to the router by the device.

After you set these parameters, please click

to make them valid.

22

EQN100 7.3.5 Email Setting To set the mailbox addresses and parameters of alarm mails and public network IP mails.

[SMTP server]: Enter the IP address or the host name of the SMTP server used to send e-mails. [From]: Input the sender’s e-mail address, so that the receiver can recognize the sender when an event message is received. [To]: Input the e-mail addresses for receiving an e-mail message when events occur. [SMTP Username]: The login user name of the mailbox that sends mails. [Password]: The login password of the mailbox that sends mails. [MAIL Title]: Title of mails. [SMTP Port]: Port of SMTP port, different mail server has different port. For example, the server port of Gmail is 465. Commonly used mail server configuration: Gmail mail server: SMTP server: smtp.gmail.com SMTP user name: [email protected] SMTP port: 465 SSL: enabled Yahoo mail server: SMTP server: smtp.mail.yahoo.com SMTP user name: [email protected] or [email protected] SMTP port: 465 SSL: enabled 163 mail server: SMTP server: smtp.163.com SMTP user name: username SMTP port: 25 SSL: disabled [SSL]: Check the box to enable the SSL function. Enable this function means you can access the camera through the SSL protocol that provides communication security over the Internet. After you set these parameters, please click

to make them valid. 23

EQN100 7.3.6 FTP Setting FTP server sends the record files and snapped images generated after alarm is triggered in FTP mode to specified FTP server, supports 2 FTP servers, when the preferred one goes wrong, system will switch to the alternate one.

[Server URL]: The IP address or HTTP address of FTP server. [Server Port]: Port of FTP server, the default port is 21. [FTP Catalog]: Path on remote FTP server, if the path does not exist or has not been filled in, the device will create a file folder under the root directory of FTP server. [User name] and [Password]: User name and password of FTP server. Note: If you want to upload the record files and snapped images, you must have the authority to write on the FTP server.

24

EQN100 7.3.7 DDNS Setting DDNS (Dynamic Domain Name System) is a service used to map a domain name to the dynamic IP address of a network device. It assigns a domain name (URL) to the IP camera, so that the user does not need to go through the trouble of checking if the IP address assigned by DHCP Server has changed. Once the IP is changed, the IP camera will automatically update the information to the DDNS to ensure it is always available for remote access.

[Enable]: Check the box to enable the DDNS function. [IP Camera Name]: Enter to register a free host name from EverFocus DDNS Server. After clicking camera.

, the following message pops-up. Click Login to re-login the IP

Note that EverFocus provides free DDNS host name. If you want to check whether the host name you desired is available, go to www.everfocusddns.com for a quick check.

1. Enter a host name in the box field. 2. Click the Check button. 3. If the host name is available, the xxx is available text will be displayed above the box field. 25

EQN100 7.3.8 VPN Setting

[Enable]: Enable or disable VPN function. [Server URL]: IP address or domain of VPN server. [User Name]: User registered in VPN server. [Password]: User password registered in VPN server. [IP]: Display IP after VPN dial-up success. [Status]: Display the status of dial-up. After you set these parameters, please click

to make them valid.

26

EQN100 7.3.9 RTSP Setting

[Enable RTSP]: Check RTSP switch to enable RTSP function, RTSP function enabled as default. [Enable Authentication]: Check encryption switch, disabled as default, when enable encryption, you need the password when using VLC player connect camera. Open: rtsp://ip/av0_0&user=admin&password=admin; Close:rtsp://ip/av0_0[&user=admin&password=admin],” [ ]” Optional content; “av0_0 ”,frist“0” shows channel:0,1,2,3,represent the channel :1,2,3,4;IP camera has only one channel, fill in“0”; The second “0” shows main / sub stream, 0: main stream, 1: sub stream; If the authentication mode is changed, the camera reboots. RTSP port: Default port is 554. With RTSP function enabled, users can review the audio and video streams in real time via players that supports standard RTSP protocol [Communicate]: Multicast function is enabled as default. [Multicast Server Address]: When camera support multicast, camera will be the multicast server, and have the multicast address, 239.0.0.0 as default address. Multicast port, video of main stream and sub stream using port 5010 and 5020, audio of main stream and sub stream using port 5012 and 5022. [Onvif Password Enable]: Check the box to enable Onvif password. After you set these parameters, please click

to make them valid.

27

EQN100 7.3.10 IP Email

[Enable Email]: Check this switch to enable public IP mail notification function. [Update Interval]: Select the interval of public IP mail notifications. After enable this function, when the device detects public IP changed, it will send notification mail to the mail address set in [mail setting]. After you set these parameters, please click

to make them valid.

28

EQN100 7.3.11 Connect Setting

[Enable]: Enable or disable active connection of the device to surveillance center. [Server URL]: The address of surveillance center (e.g. 192.168.55.99). [Server Port]: The port of surveillance center (e.g. 6000). After setting all the network parameters, click

to make the parameters valid.

29

EQN100 7.4

Alarm Settings

7.4.1 Motion Detection You can set up motion detection function on this page. When a motion event is detected, the camera will send E-mail, take a snapshot or record live views. You can then set up to send Snapshots or Recordings to the pre-configured E-mail or FTP server.

[Motion Detection Area]: Click the button to start configuring motion areas. On the preview window, draw a rectangle area on the preview window using your mouse. Up to four rectangle areas can be set up. [All]: Click to set the whole video as motion detection area. [Clear]: Click to clear all motion detection areas. [Sensitivity]: Sensitivity range is 1~5, greater value means higher sensitivity. [Enable]: Enable or disable motion detection. [Time]: Set the period of time for motion detection, two periods allowed. [Linkage Alarm output]: Support sending Email, taking snapshot and record when a motion event occurs. E-mail: Send motion detection alarm messages to users via E-mail, details about E-mail setting please refer to 7.3.5 Email Setting. Snapshot: When motion alarm is triggered, the camera will automatically send a snapshot image via E-mail or FTP. For snapping parameters, you can input a number of snapshot image to send in the box. For example, if you input 10 in the box and 1 in the Snap __ s box, when there is a motion alarm, 10 snapshot images will be snapped and send to E-mail or FTP, and the interval between each picture is 1 second. Please refer to Step 4 below. Record: When a motion alarm is triggered, the camera will automatically send a recording via E-mail or FTP with the setup interval. Please refer to Step 4 below. 30

EQN100 After setting all the parameters, click

to make the parameters valid.

Note: Record file packet time equals duration of alarm add the record time set in [Linkage recording].

To set up a Motion Area: 1. 2.

Click the Motion area set button. Use your mouse to draw a rectangle area on the screen. Up to four rectangle areas can be set up. You can also click All to set up the entire stream for motion detection.

3.

Select a motion sensitivity level from the drop-down list and check the Enable box to enable the motion detection function. Set up a period of time for motion detection. Two periods are allowed. In the Linkage Alarm output field, you can check the event actions boxes of E-mail, Snapshot or Record to enable these alarm actions when the camera detects motion events. a. E-mail: Check the box to send motion detection alarm messages to users via E-mail. For this function to work, you have to configure E-mail setting in advance. Please refer to 7.3.5 Email Setting. b. Snapshot: When motion alarm is triggered, the camera will automatically send a snapshot image via E-mail or FTP. For snapping parameters, you can input a number of snapshot image to send in the box. For example, if you input 10 in the box and 1 in the Snap __ s box, when there is a motion alarm, 10 snapshot images will be snapped and send to E-mail or FTP, and the interval between each picture is 1 second. c. Record: When a motion alarm is triggered, the camera will automatically send a recording via E-mail or FTP with the setup interval. Click Save, the configured areas will be applied with motion detection. To clear motion areas, click Clear and then click the Save button.

4.

5. 6.

31

EQN100 7.5

System Setting

7.5.1 System Info

[Device Name]: Enter a device name. [VO Standard]: Select NTSC or PAL from the drop-down list. [Language]: Select a language from the drop-down list. After changing the language, please reopen the IE browser to login the camera again. [Device ID]: Displays the device ID. [Version]: Displays the firmware version. After setting all the parameters, click

to make the parameters valid.

32

EQN100 7.5.2 System Time On this page, you can configure camera time from one of the three methods: NTP Server, Synchronize with Local Computer or Manually configure. Note: Before start operating the IP camera, please make sure the camera date and time are correct.

[NTP Server]: After starting the function, switch on NTP switch and select time zone, and click Save, the camera will send the query to NTP server, after getting the message from NTP server, the camera will upgrade the system time, the system time will be displayed on live view. [Synchronize with Local Computer]: After starting the function, the date and time of IP camera will be synchronized with the local PC. [Set the Time Manually]: If you select this option, you can modify the time manually. After setting all the parameters, click

to make the parameters valid.

33

EQN100 7.5.3 User Manage You can set three users for every camera, one is Administrator, the others are general users.

[Select User]: Select a user from the drop-down list. Administrator: Can operate and set all functions and parameters of IP camera. User1: Can perform operations like snapping, recording, playback, monitoring, alarm clearing, log searching and full-screen reviewing. User2: Can perform operations like visit setting, image lightness and color adjustment, etc. Note: Following are the default usernames / passwords for the account users: Administrator: user1 / 11111111 User1: user11 / user1 User2: user12 / user2

34

EQN100 7.5.4 Upgrade

Click the Browse button to find a previously prepared firmware upgrade file. Click the Upgrade button to install the new firmware. The upgrading status will be displayed. When the upgrade process is complete, the IP camera will restart automatically. Note: Do not disconnect power and the network to the unit during the upgrade sequence. The unit will reboot automatically after the upgrade has completed.

35

EQN100 7.5.5 Restore Click the Restore factory settings button to restore the camera to the factory default settings. All device parameters (including network parameters, excluding physical address) will be recovered as factory setting values.

7.5.6 Restart You can set up to manually or automatically reboot the camera.

To automatically reboot the camera, select the desired day and time from the drop-down list. To manually reboot the camera, click Reboot, a pop-up window displays. Enter the camera password, the IP camera will restart.

36

EQN100 7.5.7 System log You can search operation log and alarm log on this page. The maximum capacity is 512 entries of message, when the number of entries exceeds 512, the camera will delete records of the earliest date automatically.

To search log events, select a time period and click the Search button.

37

EQN100

8. Alarm Search When there is an alarm, the alarm status will be displayed on the Alarm tab

.

Click [Alarm] to enter the alarm log search page for searching the alarm log data. The maximum capacity is 512 entries of message, when the number of entries exceeds 512, system will delete records of the earliest date automatically. To search the alarm log, enter the desired date and click the Search button.

38

EQN100

9. Specifications Camera Megapixel Pickup Device Lens Min. Illumination Day/Night Shutter Time Video Video Compression Max. Video Resolution Frame Rate Video format S/N Ratio Privacy Mask Region of Interest DNR Network Interface Supported Protocols Function Video Streaming Image Settings Event Trigger Notification General Power Supply Max. Power Consumption Humidity Operating Temperature Dimensions (L x W x H) Weight Certificates

1.3MP 1/3” progressive CMOS sensor Fix focal lens 6mm (optional: 2.8mm, 3.6mm, 6mm, 8mm) Color: 0.05 Lux @F1.2 / Black: 0.01 Lux @F1.2 Easy Day / Night 1/25 ~ 1/8000sec. H.264 / M-JPEG 1280 x 1024 25fps / 30fps 50Hz / 60Hz > 50dB Yes Yes 3DNR 10BASE-T / 100BASE-TX TCP/IP, UDP, ICMP, DHCP, NTP, DNS, DDNS, SMTP, FTP, HTTP, PPPoE, RTP, RTSP, RTCP, ONVIF Dual Streams Compression, Brightness, Sharpness, Saturation, White Balance, Exposure Control, Backlight Compensation, Mirroring of Images, Text and Image Overlay, Auto Gain Control, Auto White Balance Motion Detection Send mail notification, Upload video to FTP, Record video to PC 12VDC 2.18W 20% ~ 80% not condensing 0°C ~ 50°C / 32°F~122°F 38 x 36.5 x 42.8mm / 1.5” x 1.4” x 1.7” 125g / 0.28lb (with cable) CE, FCC

39

EQN100

10. Appendix

Appendix 1 Network Interface of IP Camera The default network ports of IP camera are: 80 5000

Web port TCP Communication port, audio/video data transmission port, talkback data transmission port UDP 5000 Audio/video data transmission port Multi-cast port Multicast original port + channel number ONVIF 2000

Appendix 2 Default Network Parameters Default network parameters Cabled Network: IP Address: 192.168.1.88 Subnet mask: 255.255.255.0 Gateway: 192.168.1.1

Data Port: 5000 Web Port: 80 DHCP: Off

40

EverFocus Electronics Corp. EverFocus Taiwan: 12F-1, No.79, Sec. 1, Shin-Tai Wu Road, Hsi-Chih, New Taipei City, Taiwan TEL: +886 2 2698 2334 FAX: +886 2 2698 3943 www.everfocus.com.tw [email protected]

EverFocus Europe - Germany: Albert-Einstein-Strasse 1, D-46446 Emmerich, Germany TEL: +49 2822 93940 FAX: +49 2822 939495 www.everfocus.de [email protected]

EverFocus China - Beijing: Room 609, Technology Trade Building, Shangdi Information Industry Base, Haidian District, Beijing 100085, China TEL: +86 10 6297 3336~39 FAX: +86 10 6297 1423 www.everfocus.com.cn [email protected]

EverFocus China - Shenzhen: 4F, No. 2, D4 Building, Wan Yelong Industrial Park, Tangtou Road, Shiyan, Baoan, Shenzhen, Guangdong 518101, China TEL: +86 755 2765 1313 FAX: +86 755 2765 0337 www.everfocus.com.cn [email protected]

EverFocus USA - California: 1801 Highland Avenue, Unit A, Duarte, CA 91010, USA TEL: +1 626 844 8888 FAX: +1 626 844 8838 www.everfocus.com [email protected]

EverFocus Japan: 3F, Kuramochi, Building II 2-2-3 Koto-Bashi, Sumida-Ku, Tokyo, 130-0022, Japan TEL: +81-3-5625-8188 FAX: +81 3 5625 8189 www.everfocus.co.jp [email protected]

Your EverFocus product is designed and manufactured with high quality materials and components which can be recycled and reused. This symbol means that electrical and electronic equipment, at their end-of-life, should be disposed of separately from your household waste. Please, dispose of this equipment at your local community waste collection/recycling centre. In the European Union there are separate collection systems for used electrical and electronic product. Please, help us to conserve the environment we live in!

Ihr EverFocus Produkt wurde entwickelt und hergestellt mit qualitativ hochwertigen Materialien und Komponenten, die recycelt und wieder verwendet werden können. Dieses Symbol bedeutet, dass elektrische und elektronische Geräte am Ende ihrer Nutzungsdauer vom Hausmüll getrennt entsorgt werden sollen. Bitte entsorgen Sie dieses Gerät bei Ihrer örtlichen kommunalen Sammelstelle oder im Recycling Centre. Helfen Sie uns bitte, die Umwelt zu erhalten, in der wir leben!