Electrical Specification Model No. : NB-65B19-AB 1.
Rev. 00
SCOPE This specification describes the physical, functional and electrical characteristics of the 65 watts, single output +19V/3.42A, switching power supply.
2.
INPUT CHARACTERISTICS 2.1. Input Voltage Input voltage range :
90~264Vrms.
2.2. Input Frequency Input frequency range :
47~63 Hz
2.3. Input current Input current should be lower than 1.6/0.85Arms under full-load and 100/240Vrms input voltage conditions. 2.4. Inrush Current Inrush current should be less than 220A and no damage under full-load and cold start at 25℃, 240Vrms input voltage. 2.5. Leakage Current The total combined leakage current shall not exceed 100 microamperes when tested at 240Vrms, 50 Hz and not exceed 50 microamperes when tested at 100Vrms, 60 Hz in a normal operating condition. 2.6. Power Consumption Input power saving should be lower than 0.5 Watts under No-load and 115/230Vrms input voltage conditions. It would be conformed to “ENERGY STAR®” standard level V. 2.7. Efficiency Output current 3.42A/2.56A/1.71A/0.85A; input voltage 115/230Vrms, sum of each efficiency division 4 should be greater than 87%. It would be conformed to “ENERGY STAR®” standard level V.
OP-04-300-04 REV.:1.9
Page 1 of 5
Electrical Specification Model No. : NB-65B19-AB 3.
Rev. 00
OUTPUT CHARACTERISTICS 3.1. Output Characteristics Output voltage, load current, voltage regulation and output noise of power supply should meet the specifications, which defined on the tables below:
Item
Table 1 Electrical Characteristics overview Remarks Performance
Output Voltage Rating Output Range
19Vdc 18.05V~19.95V
Full Load
3.42A
Min. Load
0.0A
Max. Ripple Voltage
(300mVp-p) ±1 %
Line Regulation
Hold up Time
Note 1@amb.=25℃~40℃
5 ms Min.
Turn on Time
2 s Max.
Full Load & 115Vac /60Hz input, Phase 90 degree. Vo:18.05Vdcmin@amb.=25℃ Note 2 Full Load & 115Vac /60Hz input (Operating Temp.: 0°C to 40°C) Note 2
Note 1: Ripple voltage measurement is done with an oscilloscope set at a 20M Hz bandwidth & output wire 100 mm
Adapter DC Output
Load
OP-04-300-04 REV.:1.9
DC Cable
terminated with 0.1uf ceramic capacitor & parallel with 47uf Low ESR electrolytic capacitor at full load.
0.1uF
Page 2 of 5
47uF Low ESR
Electrical Specification Model No. : NB-65B19-AB
Rev. 00
Note 2: Turn On/ /Hold up Time
Input 90~264Vac
90% ( 18.05Vdc)
+19V Output 10%
Turn on time
3.2. Output Protection : 3.2.1. Short Circuit Protection
Hold up time
: The power supply shall be latch off and no damage for shorting rail to Secondary. But the power supply shall recover automatically when the Short is removed.
3.2.2. Over Voltage Protection
: Power supply shall be latch off, before output voltage reached 29V. And the power supply shall not recover automatically unless the AC reset. Test condition: 230Vac/0.5A load.
3.2.3. Over Current Protection
: Power supply shall be prohibited output before output current reached 6A.
3.2.4. Over Temperature Protection : No deformation and no discoloration on case. 3.3. Overshoot : Output overshoot during power-on and power-off shall not exceed 20V.
4.
5.
ENVIRONMENT SECTION 4.1. Operating Temperature :
0°C
4.2. Operating Humidity
:
20%
to
80% RH
4.3. Storage Temperature
:
-20°C
to
85°C
4.4. Storage Humidity
:
5% to
95% RH
RELIABILITY 5.1. MTBF
: 130K hr minimum at 25°C, and 230Vac input voltage /full load 3.42A.
5.2. Vibration 5.2.1. Non-Operating
5.2.2. Operating OP-04-300-04 REV.:1.9
to 40°C
: Acceleration 3.5G / Frequency 10~500Hz/ Vibration duration 60 minutes/ Force Direction at X, Y, Z : Acceleration 1G / Frequency 10~500Hz/ Vibration duration 60 minutes/ Force Direction at X, Y, Z Page 3 of 5
Electrical Specification Model No. : NB-65B19-AB 5.3. Drop
6.
Rev. 00
: A sample has no safety hazard after be subjected to 3 times impact , which the sample must be dropped from 100 cm onto hard marble surface.
SAFETY SECTION 6.1. Hi-Pot Test The adaptor belongs to product of CLASS I, its secondary is connected with protection earth directly. According to safety IEC60950 and IEC60065: In-Process: Primary to secondary with PE : AC 1500V or DC 2121V, 10mA Max. 1 Second for mass production. 6.2. Safety conforming
Type(Marking) Country/Region UL/CUL(or CSA)
USA Canada
FCC
USA
Energy Star
USA
CEC
California
CB GS
IEC Germany
Standard UL 60950-1 and UL 60065 CAN/CSA C22.2 No. 60950-1 and CAN/CSA-C22.2 No. 60065 ANSI C63.4-2003;FCC Part 15 Class B ENERGY STAR Program Requirements for External Power Supplies (Version 2.0) California Code of Regulations, Title 20, Sections 1601 through 1608(Phase 2) IEC 60950-1 and IEC 60065 EN 60950-1 and EN 60065 73/23/EEC and the amendment directive: 2006/95/EC (IEC/EN 60950-1 or IEC/EN 60065) 89/336/EEC and the amendment directive:2004/108/EC
CE
Europe
(EN61000-3-2 & EN61000-3-3; EN55022 Class B & EN55024 or EN55013 & EN55020) ErP Directive: 2009/125/EC and the Implementing
CCC
China
BSMI
Taiwan
KC Mark
Korea
Measures (EC)No 278/2009 GB4943; GB 9254 ; GB 17625 and GB8898;GB13837;GB17625.1 CNS 13438; CNS14336 and CNS 14408; CNS14336; CNS13438 K60950-1 ;K00022;K00024 and K60065
K-MEPS
Korea
MKE’s Notification 2008-99
SAA
Australia & New Zealand
AS/NZS60950.1 and AS/NZS 60065
C-Tick
Australia & New Zealand
AS/NZS CISPR22 or AS/NZS CISPR13
MEPS
Australia & New Zealand
AS/NZS 4665.1
PSE
Japan
J 60950 ;J55001 and J 60065 ;J55013
VCCI
Japan
VCCI Class B
OP-04-300-04 REV.:1.9
Page 4 of 5
Electrical Specification Model No. : NB-65B19-AB 7.
Rev. 00
EMC SECTION : 7.1. EMI design to meet following standards 7.1.1. FCC part 15J Class B : United States Federal Communication Commission (FCC) Rules and Regulations.” Part 15, Subpart J Class B Limit. 7.1.2. CISPR 22 (EN 55022) Class B : 1998 Information technology equipment Radio disturbance Characteristics -Limits and methods of measurement. Definitions. Information technology equipment (ITE) Class B Limit. 7.2. EMS design to meet EN55024 standards 7.2.1. EN 61000-4-2 : Electrostatic air discharge ±15KV, Contact Discharge: ±8KV. criterion B 7.2.2. EN 61000-4-3 : Radiated Susceptibility 3Vrms/m, criterion A 7.2.3. EN 61000-4-4 : Transient Burst :±1KV, criterion B 7.2.4. EN 61000-4-5 : Surge Immunity Test: ±2KV (common), ±1KV (differential), Criterion B.
8.
ENVIRONMENT STANDARD : 8.1. ROHS Directive 2002/95/EC : 8.2. WEEE Directive 2002/96/EC : Waste electrical and electronic equipment APD following WEEE Directive (Article 4 &6&10)
9.
MECHANICAL SECTION 9.1. Dimension
: Refer to mechanical drawing for the details.
APD Proprietary Information / Document : No publicity , transmission to third party or competitor is allowed without APD Prior written consent.
OP-04-300-04 REV.:1.9
Issue Date
Approved by
2011-07-10
Page 5 of 5
Checked by
Prepared by 黄晓波