3 Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom
Dynatel™ 900 Series Subscriber Loop Test Products Rugged and portable for harsh environments, Dynatel 900 Series test sets offer the right mix of functions, from loop diagnostic routines to fault locating, transmission testing and combination test/terminal capabilities. 965DSP/xDSL Subscriber Loop Analyzer
429
965DSP/xDSL The Subscriber Loop Analyzer is a microprocessor-controlled integrated test set that provides full-featured POTS, wideband and DSL-specific testing. The functions include fault location and repair verification on twisted-pair and drop cables (utilizing capacitance bridge, resistance bridge and Time Domain Reflectometer (TDR) functions). The Dynatel 965DSP/xDSL subscriber loop analyzer executes a wide range of individual tests, or performs automatic test routines to categorize and sectionalize problems. The hand-held 965DSP/xDSL test set is housed in a lightweight, ergonomically designed case for portability and ease of handling. The unit is weather-resistant and weighs only 4.3 pounds (1.95 kg). Dynatel ™
430
965/I Wideband Subscriber Loop Analyzer The Dynatel 965/I Wideband Subscriber Loop Analyzer performs all the tests needed to analyze and troubleshoot subscriber loops, as well as provide line pre-qualification tests for basic rate ISDN service. In addition, the 965/I wideband loop analyzer uses combinations of these measurements in automatic functions called DC Line Test and AC Line Test. In these test sequences, the microprocessor of the 965/I loop analyzer interprets the results of the measurements and leads the operator toward possible solutions to complex cable problems.
965M/MC Subscriber Loop Analyzer The Dynatel 965M and 965MC Subscriber Loop Analyzers are microprocessor-controlled portable instruments for measuring, diagnosing and locating conductor faults in telephone cables. These lightweight, highly-accurate weather-resistant units are used in international applications between the telephone exchange and the subscriber’s premises. The 965M and 965MC are the metric equivalent of the 965 and are available in many languages for international applications.
Accessories and Replacement Parts
300
pg. 322
3
945DSP Subscriber Loop Tester
431
Kit Contents for Subscriber Loop Test Products Product Number
965DSP/xDSL
965/I
965M/MC
945DSP
Analyzer
•
•
•
•
Conductor strap
•
•
•
Wire gauge
•
•
•
Self-test circuit board
•
•
•
Alkaline battery holder
•
Nickel metal hydride battery pack
•
AC adapter
•
Specified batteries
•
•
4 alkaline AA
Specified test cables
•
•
•
•
Instruction manual
•
•
•
•
Subscriber Loop Test Products
The Dynatel 945DSP Subscriber Loop Tester is a microprocessor-controlled test set that provides full-featured POTS testing. The 945DSP subscriber loop tester performs a wide range of voice band tests to analyze problems on twisted-pair cables. Weather-resistant and weighing only 1 pound, the handheld 945DSP test set is housed in a lightweight case for portability and ease of handling.
Optional accessories available 1678 Single unit battery charger kit
054007-71681
1682 single unit battery charger kit
054007-71685
1030 conductor gauge
054007-31253
Alkaline battery holder
051138-57685 [534389]
110/220 VAC adapter
051138-57606 [534383]
Softcase
051138-57605 [534382]
Nickel metal hydride battery pack
051138-57686 [534387]
Black/red test lead, alligator, bed-of-nails
051138-57648 [534384]
Black/red test lead, banana
051138-57608
Blue/yellow test lead, alligator bed-of-nails
051138-57649 [534385]
Blue/yellow test lead, banana
051138-57610
Green test lead, alligator, bed-of-nails
051138-57650 [534386]
Green test lead, banana
051138-57612
Ground strap, alligator
051138-58529
Ground strap, 4 mm banana
051138-58532
Video training tape
optional*
054007-31253
051138-57648
051138-57650
optional*
051138-57744 [534388]
Printer IR adapter
051138-89331
051138-89331
051138-89332
051138-89332
IR adapter cable
051138-58764 [569397]
1162 KM box (K-test adapter)
051138-70089
Far end device
051138-89322
1.2 MHz ADSL Upgrade
054007-31253
yes
Cigarette adapter Seiko DPU-414 Printer Package
054007-31253
051138-70498 [569394]
301
3
Features for the 900 Series Subscriber Loop Test Products
Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom
Features
302
965DSP
965xDSL
965 DSP-B
965/I
Resistance fault locate
•
•
•
•
Open fault locate
•
•
•
•
Load coil count
•
•
•
•
Longitudinal balance
•
•
•
•
Caller Identification (CID)
•
•
•
(Optional)
Split fault locate
•
•
•
•
945DSP •
•
Voltage measurement
•
•
•
•
•
Tone source
•
•
•
•
•
Current measurement
•
•
•
•
•
Ohms measurement
•
•
•
•
•
Ohms-to-distance conversion
•
•
•
•
Loss measurement
•
•
•
•
•
Noise measurement
•
•
•
•
•
REG detection
•
Ringers count
•
•
•
•
Self-test and self-calibration
•
•
•
•
Wideband noise/loss for ISDN and HDSL
•
•
•
Line Prequalification tests for basic rate ISDN service
•
•
•
TDR (echometer)
•
•
IR port
•
•
•
Internal memory
•
•
•
Communications craft set Measurement units
Backlit pixel full graphic display
•
•
•
Feet, meters, Fahrenheit, Celsius
Feet, meters, Fahrenheit, Celsius
Feet, meters, Fahrenheit, Celsius
•
•
•
4 x 20 character backlit LCD display
Feet, Fahrenheit
•
•
•
Auto diagnostic AC testing (transmission)
•
•
•
High insulation resistance test
•
•
Resistance difference and loop resistance
•
•
Spectrum analyzer
•
E, F, G, filtering
•
•
Soak test
V6.0
•
V6.0
Kick test
V6.0
•
V6.0
•
•
•
Feet, meters, Fahrenheit, Celsius •
•
Auto diagnostic DC testing (loop)
Onboard operating instructions
•
•
965xDSL
965 DSP-B
965/I
945DSP
3
965DSP Ordering Information Packaging Minimum order
Nickel Metal Hydride batteries, bed-of-nails clips, US Nickel Metal Hydride batteries, 4 mm banana plugs, multi-language Nickel Metal Hydride batteries, bed-of-nails clips, US w/out TDR CID, alkaline batteries, single needle clips CID, alkaline batteries, bed-of-nails clips CID, NiCd batteries, single needle clips CID, NiCd batteries, bed-of-nails clips Bed-of-nails clips/c-message weighting Bed-of-nails clips/psophometric filter Single needle clips/c-message weighting Single needle clips/psophometric filter TDR upgrade kit
1/cs.
1/cs.
1/cs.
1/cs.
1 each
1 each
1 each
1 each
N/A N/A
N/A N/A
N/A N/A
051138-57603 [533623] 051138-58528
051138-57603 [534373] 051138-58528
N/A 051138-57621 [87240374] N/A N/A
N/A
N/A
051138-58643
N/A
N/A
N/A
N/A
N/A
N/A
N/A N/A N/A
N/A N/A N/A
051138-57622 N/A N/A
N/A N/A N/A 051138-87220 051138-87221 051138-87222 051138-87223
Available Q4
051138-58770 [534380]
N/A
Subscriber Loop Test Products
UPC Alkaline batteries, single needle clips Alkaline batteries, bed-of-nails clips
1/cs. 1 each
303
3
Features for the 900 Series Subscriber Loop Test Products (metric versions)
Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom
Features
304
965M
965MC
Resistance fault locate
•
•
Open fault locate
•
•
Load coil count
•
•
Longitudinal balance
•
Caller Identification (CID) Split fault locate
•
•
Voltage measurement
•
•
Tone source
•
•
Current measurement
•
•
Ohms measurement
•
•
Ohms-to-distance conversion
•
•
Loss measurement
•
•
Noise measurement
•
•
REG detection
•
•
Ringers count
•
•
Self-test and self-calibration
•
•
Meters, Celsius
Meters, Celsius
Auto diagnostic DC testing (loop)
•
•
Auto diagnostic AC testing (transmission)
•
•
•
•
1/cs.
1/cs.
Wideband noise/loss for ISDN and HDSL Line Prequalification tests for basic rate ISDN service TDR (echometer) IR port Internal memory Communications craft set Measurement units Backlit pixel full graphic display
High insulation resistance test Resistance difference and loop resistance 4 x 20 character backlit LCD display
Ordering Information Packaging Minimum order
1 each
1 each
Alkaline batteries, single needle clips Alkaline batteries, bed-of-nails clips
N/A 054007-72006
N/A 054007-72007
CID, alkaline batteries, bed-of-nails clips CID, NiCd batteries, single needle clips CID, NiCd batteries, bed-of-nails clips
054007-92271
N/A
N/A N/A
N/A N/A
3
Specifications for 965DSP Subscriber Loop Analyzer (A, B and xDSL) Measurement Function
Range
Resolution
Size H x W x D in. (cm) Cord length ft. (m)
Accuracy ±
10.3 x 4.7 x 3.2 (26.1 x 11.9 x 8.1) 5 (1.5) 4.3 with battery and softcase (1.95)
Shipping weight lbs. (kg)
7.8 (3.54)
Operating temperature
0° to 140°F (-18° to 60°C)
Storage temperature
-40° to 165°F (-40° to 75°C)
Relative humidity
0 to 95%, non-condensing
Operating altitude
0 to 16,600 ft. (0 to 5000 m)
Display in. (cm)
2.5 x 2.5 (74 x 74), 192 by 192 pixel resolution, backlight
AC voltage
0 to 99.9 V 100 to 250 V
0.1 V 1V
1% ± 0.5 V 3%
DC voltage
0 to 99.9 V 100 to 300 V
0.1 V 1V
1% ± 0.5 V 3%
DC current
0 to 59.9 mA 60 to 110 mA
0.1 mA 0.1 mA
1% ± 0.3 mA 2%
Resistance (DC) with CO voltage
0 to 9999 Ω 0 to 9999 Ω 10 k to 99.9 kΩ 100 k to 999 kΩ 1 M to 9.9 MΩ 10 M to 99 MΩ 100 M to 990 MΩ
1Ω 1Ω 0.1 kΩ 1 kΩ 0.1 MΩ 1 MΩ 10 MΩ
1% ± 5 Ω 1% ± 50 Ω 1% 3% 3% 5% 10%
Opens (no noise)
0 to 3000 ft. (0 to 1000 m) 3000 to 10000 ft. (1 km to 3 km) 10k to 50k ft. (3 km to 15 km) 50k ft. to 100k ft. (15 km to 30 km)
1 ft. (1 m) 1 ft. (1 m) 10 ft. (10 m) 100 ft. (100 m)
1% ± 3 ft. (1 m) 3% 5% 10%
0 to 20 MΩ 0 to 99.99 Ω RTS 100 to 999.9 Ω RTS 1 kΩ to 7 kΩ RTS
— 0.01 Ω 0.1 Ω 1.0 Ω
— 0.1% of RTS ± 0.01 Ω 0.2% of RTS ± 0.01 Ω 1% of RTS ± 0.01 Ω
-40 to +10 dBm, 200 to 3000 Hz -40 to +10 dBm, 3000 to 9995 Hz -40 to +10 dBm, 10 k to 19.9 kHz
0.1 dB, 1 Hz 0.1 dB, 5 Hz 1 dB, 10 Hz
0.5 dB, 2 Hz 0.5 dB, 10 Hz 1 dB, 20 Hz
Wideband loss with 135 Ω Zin
-50 to +2 dBm, 20k to 1200 kHz
0.1 dB, 100 kHz
2 dB, 1%
Noise metallic with 600 Ω Zin
0 to 50 dBrnc (-90 to -40 dBm0p)
1 dB
2 dB
40 to 100 dBrnc (-50 to 10 dBm0p)
1 dB
2 dB
0 to 85 dB
1 dB
2 dB
200 to 1000 Hz, fixed level 200 to 9999 Hz, -20 to +1 dBm 10k to 19.99 kHz, -20 to +1 dBm 20k to 1200 kHz, 0 dBm
1 Hz 1 Hz, 0.1 dB 10 Hz, 0.1 dB 1 kHz
1% 1% Hz, 0.2 dB 2% Hz, 1 dB 1 dB
DTMF, Pulse
Standard
Standard
3 ft.-300 ft., 20 ft.-1,000 ft., 50 ft.-3,000 ft., 150 ft.-10,000 ft., 450 ft.-30,000 ft. (1-100 m, 5-300 m, 15-1000 m, 45-3000 m, 140-10000 m) 5 nS, 34 nS, 235 nS, 1600 nS 0.50 to 0.99 (150 to 299 m/µs) Single trace, dual trace differential, memory, crosstalk
1 ft. (1 m)
0.6% range
Fixed values 0.01 (1 m/µs) — —
— — — —
Active/inactive Near-end & far-end block errors
— — 1 Error
— — 1 Error
-75 to +5 dBm, 20 kHz to 1200 kHz
0.1 dB
1 dB
+10/+20/+30 to +90 dBm +40/+50/+60 to + 120 dBm
1 dB 1 dB
2 dB 2 dB
Same specifications as full tests
See above
See above
RFL Fault Range Resistance to Fault (no noise)
Loss (& frequency) with 600 Ω Zin
Noise to ground with 600 Ω Zin Longitudinal balance Tone output ID Precision—600 Ω Zout Wideband—135 Ω Zout Dial mode TDR* Ranges
Pulse width Velocity factor input Modes ISDN (2BIQ per ANSITI.601) Link test Error test (US & Canada only) DSL Loss (& frequency) With 100 Ω or 135 Ω Zin Noise (with E, F & G filters) Metallic with 100 Ω/135 Ω Zin Longitudinal with 10 kΩ Zin Auto tests Power source Typical battery life No backlight With backlight
Subscriber Loop Test Products
Net weight lbs. (kg)
Rechargeable 1.2 amp-hour Nickel Metal Hydride battery pack. Defined as 30 minutes on, 30 minutes off at 75°F (25°C). 12 hours 4 hours
*Not available in 965DSP-B version; available as optional factory upgrade.
305
3
Specifications for 965DSP Subscriber Loop Analyzer (A, B and xDSL) (cont.) Measurement Function Load coil count
Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom
Ringers
306
Ohms/distance Calculator Caller ID Carrier level (US & Canada only) Self-calibrate Loop resistance
Resistance difference Ground resistance K-Test Loop resistance Fault ratio Resistance to fault (no noise) Stored results (Autotest and TDR)
Range
Resolution
Accuracy ±
0 to 5
1
±1
0 to 2000 nf, 0 to 4.0
10 nF, 0.1 Ω
—
0 to 9999 Ω 0 to 99,999 ft. (0-30 km)
0.01 Ω 1 ft. (0.1 m)
— —
Date, time, number, name -4 to -32 dBm
— 1 dBm
— 2 dBm
0 to 99.9 Ω 100 to 999.9 Ω 1000 to 7000 Ω
0.01 Ω 0.1 Ω 1Ω
0.1% ± 0.01 Ω 0.2% ± 0.01 Ω 1.0% ± 0.01 Ω
0 to 99.99 Ω
0.01 Ω
1% of loop resistance ± 0.01Ω
5 to 500 Ω
1Ω
1% ± Ω
0 to 7K Ω (Fault Res1) > twice (Fault Res2) 0 to 99 Ω 100 to 999 Ω 1K Ω to 3.5K Ω
– – 0.01 Ω 0.1Ω 1Ω
– – 5% 5% 5%
Pass/fail
100 results of each, minimum
3
Specifications for the 965/I Subscriber Loop Tester Measurement Function
Range
Resolution
Size H x W x D in. (cm) Cord length ft. (m)
Accuracy ±
7.0 x 10.5 x 7.5 (17.8 x 26.7 x 19.1) 5 (1.5) 7.5 (3.4)
Shipping weight lbs. (kg)
10.5 (4.8)
Operating temperature
32° to 122°F (0° to 50°C)
Storage temperature
-40° to 165°F (-40° to 74°C)
Relative humidity
0 to 100%
Operating altitude
0 to 15,000 ft. (0 to 5000 m)
Storage altitude
0 to 40,000 ft. (0 to 12000 m)
AC voltage
0 to 75 V 75 to 250 V
0.1 V 1.0 V
0.7V 3%
DC voltage
0 to 100 V 100 to 350 V
0.1 V 1.0 V
0.5 V 3%
DC current
0 to 110 mA (Zin = 430 ohms)
0.1 mA
0.3 mA
Resistance
0 to 100 Megohms
100 ohms @ 50K ohms
1% @ 50K ohms
-40 to 10 dBm (Zin = 600 ohms) -40 to 10 dBm (Zin = 135 ohms)
0.1 dB 400 to 5000 Hz 0.1 dB 20,000 to 40,000 Hz
0.2 dB
Noise metallic (differential)
10 to 50 dBrnC 0 to 10 dBrnC (Zin = 600 ohms)
0.1 dB 0.3 dB
0.5 dB 2.0 dB
Noise to ground (common mode)
40 to 100 dBrnC (Zin = 600 ohms)
0.1 dB
0.5 dB
Opens (normal mode)
0 to 9,990 ft. 10,000 to 100,000 ft.
10 ft. 100 ft.
±1% +10/-1%
Opens (special mode)
0 to 999 ft. 1,000 to 10,000 ft.
1 ft. 10 ft.
±1% +10/-1%
20 to 20,000 Hz 20,000 to 40,000 Hz
1 Hz 1 Hz 0 to 50°C
2 Hz 5%
Ground resistance
0 to 500 ohms
1 ohm
3 ohms
Loop and CO resistance
0 to 5000 ohms
1 ohm
50 ohms
0 to 30 Megohms 0 to 7000 ohms
.01 ohms @ 50 ohms
± (0.001xRS+2x10-8x RF) ohms
1 to 1,000 ft. 1,000 to 10,000 ft. 10,000 to 100,000 ft.
0.1 ft. 1 ft. 10 ft.
Loss
Frequency counter (during loss, single frequency only)
Resistance fault locate Fault range Resistance to fault at 70° F and no noise Resistance to feet conversion
Noise immunity Outputs Precision tones Tracing tone DTMF
Dial pulse Power source
1.0 dB
7 Vac limit for all frequencies Frequency 404, 1004, 2804 Hz ±1 Hz 39,038 Hz 577.5 Hz
Level 0 dBm ± 0.2 dB 0 dBm ± 1 dB 3 V pk to pk
Impedance @ 600 ohms 135 ohms 100 ohms (Current limited to 6 mA)
Standard
100 ms ON,100 ms OFF
Meets CC1TT Q.23 Standard for frequency and amplitude (±1 Hz 0-10 dBm ±1 dB)
10 pulses per second
60 ms break, 40 ms Make, 600 ms between digits
R-T
Five “C” cell alkaline or rechargeable NiCd batteries (optional)
Typical battery life No backlight With backlight
40 hrs. on fully charged NiCd, 120 hrs. on alkaline 12 hrs. on fully charged NiCd, 35 hrs. on alkaline
Temperature sensor
0° to 140°F (-18° to 60°C)
Harmonic distortion
4000 Hz
0 to 30 Megohms 0 to 7,000 ohms 1 to 99 m 100 to 999 m 1000 to 30000 m
.01 ohm @ 50 ohms 0.1 m 1m 10 m
±(0.001 x RS +2 x 10-8 x RF) ohms
-18° to 60°C (0° to 140°F)
0.56°C (1°F)
±1°C (±2°F)
Frequency
Level
Impedance
Loss Differential 965M 965MC
Common mode 965M 965MC Opens (normal mode) Frequency counter Resistance fault locate Fault range Resistance to fault Resistance to feet conversion
Temperature sensor Outputs Tracing tone 965M 965MC Precision tones 965M 965MC
577.5 Hz 480 Hz
0 dBV 0 dBV
100 ohms (current limited to 8 mA) 100 ohms (current limited to 8 mA)
404, 1004, 2804 Hz ±1 Hz 800, 1020 ±1Hz
0 dBm ± 0.2 dB 0 dBm ± 0.2 dB
@ 600 ohms @ 600 ohms
Variable source
50 Hz to 10 kHz
±1% @ 1 kHz
±1 dB
Power line frequency 965M 965MC Power source Typical battery life
Subscriber Loop Test Products
Net weight kg (lbs.)
Set at 60 Hz User selectable between 50/60 Hz Five “C” cell alkaline batteries Alkaline: 200 hours Nickel-cadmium: 80 hours between charges
309
3
Specifications for the 955M/MC Combination Fault Locator Measurement Function
Range
Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom
Size H x W x D cm (in.) Cord length m (ft.)
310
Resolution
Accuracy ±
17.8 x 26.7 x 19.1 (7.0 x 10.5 x 7.5) 1.5 (5)
Net weight kg (lbs.)
3.4 (7.5)
Shipping weight kg (lbs.)
4.8 (10.5)
Operating temperature
-18° to 60°C (0° to 140°F)
Storage temperature
-40° to 74°C (-40° to 165°F)
Relative humidity
0 to 100%
Operating altitude
0 to 5000 m (0 to 15,000 ft.)
Storage altitude
0 to 12000 m (0 to 40,000 ft.)
AC voltage
0 to 75 V 75 to 250 V
0.1 V 1.0 V
0.7 V 3%
DC voltage
0 to 100 V 100 to 350 V
0.1 V 1.0 V
0.5 V 3%
DC current
0 to 110 mA (Zin = 430 ohms)
0.1 mA
0.3 mA
Resistance
0 to 100 Megohms
100 ohms @ 50K ohms
1% @ 50K ohms
0 to 30000 m
3 m @ 500 m
1.5 m ±1% @ 500 m
577.5 Hz 480 Hz
0 dBV @ 100 ohms 0 dBV @ 100 ohms
Current limited to 8 mA Current limited to 8 mA
1004 Hz 800 ±1 Hz, 1020 ±1 Hz
0 dBm ±0.2 dB @ 600 ohms 0 dBm ±0.2 dB @ 600 ohms
0 to 30 Megohms 0 to 7000 ohms 1 to 99 m 100 to 999 m 1000 to 30000 m
.01 ohm @ 50 ohms 0.1 m 1m 10 m
±(0.001 x RS +2 x 10-8 x RF) ohms
-18° to 60°C
0.5°C
±1°C
Outputs Precision tone Tracing tone
Frequency 1004 Hz ±1 Hz 577.5 Hz ±1 Hz
Level 0 dBm ±0.2 dB 6 V pk to pk
Impedance @ 600 ohms Current limited to 8 mA
Variable source (955MC only)
50 Hz to 10 kHz
±1% @ 1 kHz
±1 dB
Opens (normal mode) Trace tone: 955M 955MC Reference tone: 955M 955MC Resistance fault locate Fault range Resistance to fault Resistance to meters conversion
Temperature sensor
Power source Typical battery life
Five “C” cell alkaline batteries Alkaline: 200 hours