Dynatel 900 Series Subscriber Loop Test Products

3 Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom Dynatel™ 900 Series Subscriber Loop Test Products Rugged and portable for harsh environments...
Author: Douglas Pearson
41 downloads 0 Views 163KB Size
3 Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom

Dynatel™ 900 Series Subscriber Loop Test Products Rugged and portable for harsh environments, Dynatel 900 Series test sets offer the right mix of functions, from loop diagnostic routines to fault locating, transmission testing and combination test/terminal capabilities. 965DSP/xDSL Subscriber Loop Analyzer

429

965DSP/xDSL The Subscriber Loop Analyzer is a microprocessor-controlled integrated test set that provides full-featured POTS, wideband and DSL-specific testing. The functions include fault location and repair verification on twisted-pair and drop cables (utilizing capacitance bridge, resistance bridge and Time Domain Reflectometer (TDR) functions). The Dynatel 965DSP/xDSL subscriber loop analyzer executes a wide range of individual tests, or performs automatic test routines to categorize and sectionalize problems. The hand-held 965DSP/xDSL test set is housed in a lightweight, ergonomically designed case for portability and ease of handling. The unit is weather-resistant and weighs only 4.3 pounds (1.95 kg). Dynatel ™

430

965/I Wideband Subscriber Loop Analyzer The Dynatel 965/I Wideband Subscriber Loop Analyzer performs all the tests needed to analyze and troubleshoot subscriber loops, as well as provide line pre-qualification tests for basic rate ISDN service. In addition, the 965/I wideband loop analyzer uses combinations of these measurements in automatic functions called DC Line Test and AC Line Test. In these test sequences, the microprocessor of the 965/I loop analyzer interprets the results of the measurements and leads the operator toward possible solutions to complex cable problems.

965M/MC Subscriber Loop Analyzer The Dynatel 965M and 965MC Subscriber Loop Analyzers are microprocessor-controlled portable instruments for measuring, diagnosing and locating conductor faults in telephone cables. These lightweight, highly-accurate weather-resistant units are used in international applications between the telephone exchange and the subscriber’s premises. The 965M and 965MC are the metric equivalent of the 965 and are available in many languages for international applications.

Accessories and Replacement Parts

300

pg. 322

3

945DSP Subscriber Loop Tester

431

Kit Contents for Subscriber Loop Test Products Product Number

965DSP/xDSL

965/I

965M/MC

945DSP

Analyzer









Conductor strap







Wire gauge







Self-test circuit board







Alkaline battery holder



Nickel metal hydride battery pack



AC adapter



Specified batteries





4 alkaline AA

Specified test cables









Instruction manual









Subscriber Loop Test Products

The Dynatel 945DSP Subscriber Loop Tester is a microprocessor-controlled test set that provides full-featured POTS testing. The 945DSP subscriber loop tester performs a wide range of voice band tests to analyze problems on twisted-pair cables. Weather-resistant and weighing only 1 pound, the handheld 945DSP test set is housed in a lightweight case for portability and ease of handling.

Optional accessories available 1678 Single unit battery charger kit

054007-71681

1682 single unit battery charger kit

054007-71685

1030 conductor gauge

054007-31253

Alkaline battery holder

051138-57685 [534389]

110/220 VAC adapter

051138-57606 [534383]

Softcase

051138-57605 [534382]

Nickel metal hydride battery pack

051138-57686 [534387]

Black/red test lead, alligator, bed-of-nails

051138-57648 [534384]

Black/red test lead, banana

051138-57608

Blue/yellow test lead, alligator bed-of-nails

051138-57649 [534385]

Blue/yellow test lead, banana

051138-57610

Green test lead, alligator, bed-of-nails

051138-57650 [534386]

Green test lead, banana

051138-57612

Ground strap, alligator

051138-58529

Ground strap, 4 mm banana

051138-58532

Video training tape

optional*

054007-31253

051138-57648

051138-57650

optional*

051138-57744 [534388]

Printer IR adapter

051138-89331

051138-89331

051138-89332

051138-89332

IR adapter cable

051138-58764 [569397]

1162 KM box (K-test adapter)

051138-70089

Far end device

051138-89322

1.2 MHz ADSL Upgrade

054007-31253

yes

Cigarette adapter Seiko DPU-414 Printer Package

054007-31253

051138-70498 [569394]

301

3

Features for the 900 Series Subscriber Loop Test Products

Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom

Features

302

965DSP

965xDSL

965 DSP-B

965/I

Resistance fault locate









Open fault locate









Load coil count









Longitudinal balance









Caller Identification (CID)







(Optional)

Split fault locate









945DSP •



Voltage measurement











Tone source











Current measurement











Ohms measurement











Ohms-to-distance conversion









Loss measurement











Noise measurement











REG detection



Ringers count









Self-test and self-calibration









Wideband noise/loss for ISDN and HDSL







Line Prequalification tests for basic rate ISDN service







TDR (echometer)





IR port







Internal memory







Communications craft set Measurement units

Backlit pixel full graphic display







Feet, meters, Fahrenheit, Celsius

Feet, meters, Fahrenheit, Celsius

Feet, meters, Fahrenheit, Celsius







4 x 20 character backlit LCD display

Feet, Fahrenheit







Auto diagnostic AC testing (transmission)







High insulation resistance test





Resistance difference and loop resistance





Spectrum analyzer



E, F, G, filtering





Soak test

V6.0



V6.0

Kick test

V6.0



V6.0







Feet, meters, Fahrenheit, Celsius •



Auto diagnostic DC testing (loop)

Onboard operating instructions





965xDSL

965 DSP-B

965/I

945DSP

3

965DSP Ordering Information Packaging Minimum order

Nickel Metal Hydride batteries, bed-of-nails clips, US Nickel Metal Hydride batteries, 4 mm banana plugs, multi-language Nickel Metal Hydride batteries, bed-of-nails clips, US w/out TDR CID, alkaline batteries, single needle clips CID, alkaline batteries, bed-of-nails clips CID, NiCd batteries, single needle clips CID, NiCd batteries, bed-of-nails clips Bed-of-nails clips/c-message weighting Bed-of-nails clips/psophometric filter Single needle clips/c-message weighting Single needle clips/psophometric filter TDR upgrade kit

1/cs.

1/cs.

1/cs.

1/cs.

1 each

1 each

1 each

1 each

N/A N/A

N/A N/A

N/A N/A

051138-57603 [533623] 051138-58528

051138-57603 [534373] 051138-58528

N/A 051138-57621 [87240374] N/A N/A

N/A

N/A

051138-58643

N/A

N/A

N/A

N/A

N/A

N/A

N/A N/A N/A

N/A N/A N/A

051138-57622 N/A N/A

N/A N/A N/A 051138-87220 051138-87221 051138-87222 051138-87223

Available Q4

051138-58770 [534380]

N/A

Subscriber Loop Test Products

UPC Alkaline batteries, single needle clips Alkaline batteries, bed-of-nails clips

1/cs. 1 each

303

3

Features for the 900 Series Subscriber Loop Test Products (metric versions)

Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom

Features

304

965M

965MC

Resistance fault locate





Open fault locate





Load coil count





Longitudinal balance



Caller Identification (CID) Split fault locate





Voltage measurement





Tone source





Current measurement





Ohms measurement





Ohms-to-distance conversion





Loss measurement





Noise measurement





REG detection





Ringers count





Self-test and self-calibration





Meters, Celsius

Meters, Celsius

Auto diagnostic DC testing (loop)





Auto diagnostic AC testing (transmission)









1/cs.

1/cs.

Wideband noise/loss for ISDN and HDSL Line Prequalification tests for basic rate ISDN service TDR (echometer) IR port Internal memory Communications craft set Measurement units Backlit pixel full graphic display

High insulation resistance test Resistance difference and loop resistance 4 x 20 character backlit LCD display

Ordering Information Packaging Minimum order

1 each

1 each

Alkaline batteries, single needle clips Alkaline batteries, bed-of-nails clips

N/A 054007-72006

N/A 054007-72007

CID, alkaline batteries, bed-of-nails clips CID, NiCd batteries, single needle clips CID, NiCd batteries, bed-of-nails clips

054007-92271

N/A

N/A N/A

N/A N/A

3

Specifications for 965DSP Subscriber Loop Analyzer (A, B and xDSL) Measurement Function

Range

Resolution

Size H x W x D in. (cm) Cord length ft. (m)

Accuracy ±

10.3 x 4.7 x 3.2 (26.1 x 11.9 x 8.1) 5 (1.5) 4.3 with battery and softcase (1.95)

Shipping weight lbs. (kg)

7.8 (3.54)

Operating temperature

0° to 140°F (-18° to 60°C)

Storage temperature

-40° to 165°F (-40° to 75°C)

Relative humidity

0 to 95%, non-condensing

Operating altitude

0 to 16,600 ft. (0 to 5000 m)

Display in. (cm)

2.5 x 2.5 (74 x 74), 192 by 192 pixel resolution, backlight

AC voltage

0 to 99.9 V 100 to 250 V

0.1 V 1V

1% ± 0.5 V 3%

DC voltage

0 to 99.9 V 100 to 300 V

0.1 V 1V

1% ± 0.5 V 3%

DC current

0 to 59.9 mA 60 to 110 mA

0.1 mA 0.1 mA

1% ± 0.3 mA 2%

Resistance (DC) with CO voltage

0 to 9999 Ω 0 to 9999 Ω 10 k to 99.9 kΩ 100 k to 999 kΩ 1 M to 9.9 MΩ 10 M to 99 MΩ 100 M to 990 MΩ

1Ω 1Ω 0.1 kΩ 1 kΩ 0.1 MΩ 1 MΩ 10 MΩ

1% ± 5 Ω 1% ± 50 Ω 1% 3% 3% 5% 10%

Opens (no noise)

0 to 3000 ft. (0 to 1000 m) 3000 to 10000 ft. (1 km to 3 km) 10k to 50k ft. (3 km to 15 km) 50k ft. to 100k ft. (15 km to 30 km)

1 ft. (1 m) 1 ft. (1 m) 10 ft. (10 m) 100 ft. (100 m)

1% ± 3 ft. (1 m) 3% 5% 10%

0 to 20 MΩ 0 to 99.99 Ω RTS 100 to 999.9 Ω RTS 1 kΩ to 7 kΩ RTS

— 0.01 Ω 0.1 Ω 1.0 Ω

— 0.1% of RTS ± 0.01 Ω 0.2% of RTS ± 0.01 Ω 1% of RTS ± 0.01 Ω

-40 to +10 dBm, 200 to 3000 Hz -40 to +10 dBm, 3000 to 9995 Hz -40 to +10 dBm, 10 k to 19.9 kHz

0.1 dB, 1 Hz 0.1 dB, 5 Hz 1 dB, 10 Hz

0.5 dB, 2 Hz 0.5 dB, 10 Hz 1 dB, 20 Hz

Wideband loss with 135 Ω Zin

-50 to +2 dBm, 20k to 1200 kHz

0.1 dB, 100 kHz

2 dB, 1%

Noise metallic with 600 Ω Zin

0 to 50 dBrnc (-90 to -40 dBm0p)

1 dB

2 dB

40 to 100 dBrnc (-50 to 10 dBm0p)

1 dB

2 dB

0 to 85 dB

1 dB

2 dB

200 to 1000 Hz, fixed level 200 to 9999 Hz, -20 to +1 dBm 10k to 19.99 kHz, -20 to +1 dBm 20k to 1200 kHz, 0 dBm

1 Hz 1 Hz, 0.1 dB 10 Hz, 0.1 dB 1 kHz

1% 1% Hz, 0.2 dB 2% Hz, 1 dB 1 dB

DTMF, Pulse

Standard

Standard

3 ft.-300 ft., 20 ft.-1,000 ft., 50 ft.-3,000 ft., 150 ft.-10,000 ft., 450 ft.-30,000 ft. (1-100 m, 5-300 m, 15-1000 m, 45-3000 m, 140-10000 m) 5 nS, 34 nS, 235 nS, 1600 nS 0.50 to 0.99 (150 to 299 m/µs) Single trace, dual trace differential, memory, crosstalk

1 ft. (1 m)

0.6% range

Fixed values 0.01 (1 m/µs) — —

— — — —

Active/inactive Near-end & far-end block errors

— — 1 Error

— — 1 Error

-75 to +5 dBm, 20 kHz to 1200 kHz

0.1 dB

1 dB

+10/+20/+30 to +90 dBm +40/+50/+60 to + 120 dBm

1 dB 1 dB

2 dB 2 dB

Same specifications as full tests

See above

See above

RFL Fault Range Resistance to Fault (no noise)

Loss (& frequency) with 600 Ω Zin

Noise to ground with 600 Ω Zin Longitudinal balance Tone output ID Precision—600 Ω Zout Wideband—135 Ω Zout Dial mode TDR* Ranges

Pulse width Velocity factor input Modes ISDN (2BIQ per ANSITI.601) Link test Error test (US & Canada only) DSL Loss (& frequency) With 100 Ω or 135 Ω Zin Noise (with E, F & G filters) Metallic with 100 Ω/135 Ω Zin Longitudinal with 10 kΩ Zin Auto tests Power source Typical battery life No backlight With backlight

Subscriber Loop Test Products

Net weight lbs. (kg)

Rechargeable 1.2 amp-hour Nickel Metal Hydride battery pack. Defined as 30 minutes on, 30 minutes off at 75°F (25°C). 12 hours 4 hours

*Not available in 965DSP-B version; available as optional factory upgrade.

305

3

Specifications for 965DSP Subscriber Loop Analyzer (A, B and xDSL) (cont.) Measurement Function Load coil count

Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom

Ringers

306

Ohms/distance Calculator Caller ID Carrier level (US & Canada only) Self-calibrate Loop resistance

Resistance difference Ground resistance K-Test Loop resistance Fault ratio Resistance to fault (no noise) Stored results (Autotest and TDR)

Range

Resolution

Accuracy ±

0 to 5

1

±1

0 to 2000 nf, 0 to 4.0

10 nF, 0.1 Ω



0 to 9999 Ω 0 to 99,999 ft. (0-30 km)

0.01 Ω 1 ft. (0.1 m)

— —

Date, time, number, name -4 to -32 dBm

— 1 dBm

— 2 dBm

0 to 99.9 Ω 100 to 999.9 Ω 1000 to 7000 Ω

0.01 Ω 0.1 Ω 1Ω

0.1% ± 0.01 Ω 0.2% ± 0.01 Ω 1.0% ± 0.01 Ω

0 to 99.99 Ω

0.01 Ω

1% of loop resistance ± 0.01Ω

5 to 500 Ω

1Ω

1% ± Ω

0 to 7K Ω (Fault Res1) > twice (Fault Res2) 0 to 99 Ω 100 to 999 Ω 1K Ω to 3.5K Ω

– – 0.01 Ω 0.1Ω 1Ω

– – 5% 5% 5%

Pass/fail

100 results of each, minimum

3

Specifications for the 965/I Subscriber Loop Tester Measurement Function

Range

Resolution

Size H x W x D in. (cm) Cord length ft. (m)

Accuracy ±

7.0 x 10.5 x 7.5 (17.8 x 26.7 x 19.1) 5 (1.5) 7.5 (3.4)

Shipping weight lbs. (kg)

10.5 (4.8)

Operating temperature

32° to 122°F (0° to 50°C)

Storage temperature

-40° to 165°F (-40° to 74°C)

Relative humidity

0 to 100%

Operating altitude

0 to 15,000 ft. (0 to 5000 m)

Storage altitude

0 to 40,000 ft. (0 to 12000 m)

AC voltage

0 to 75 V 75 to 250 V

0.1 V 1.0 V

0.7V 3%

DC voltage

0 to 100 V 100 to 350 V

0.1 V 1.0 V

0.5 V 3%

DC current

0 to 110 mA (Zin = 430 ohms)

0.1 mA

0.3 mA

Resistance

0 to 100 Megohms

100 ohms @ 50K ohms

1% @ 50K ohms

-40 to 10 dBm (Zin = 600 ohms) -40 to 10 dBm (Zin = 135 ohms)

0.1 dB 400 to 5000 Hz 0.1 dB 20,000 to 40,000 Hz

0.2 dB

Noise metallic (differential)

10 to 50 dBrnC 0 to 10 dBrnC (Zin = 600 ohms)

0.1 dB 0.3 dB

0.5 dB 2.0 dB

Noise to ground (common mode)

40 to 100 dBrnC (Zin = 600 ohms)

0.1 dB

0.5 dB

Opens (normal mode)

0 to 9,990 ft. 10,000 to 100,000 ft.

10 ft. 100 ft.

±1% +10/-1%

Opens (special mode)

0 to 999 ft. 1,000 to 10,000 ft.

1 ft. 10 ft.

±1% +10/-1%

20 to 20,000 Hz 20,000 to 40,000 Hz

1 Hz 1 Hz 0 to 50°C

2 Hz 5%

Ground resistance

0 to 500 ohms

1 ohm

3 ohms

Loop and CO resistance

0 to 5000 ohms

1 ohm

50 ohms

0 to 30 Megohms 0 to 7000 ohms

.01 ohms @ 50 ohms

± (0.001xRS+2x10-8x RF) ohms

1 to 1,000 ft. 1,000 to 10,000 ft. 10,000 to 100,000 ft.

0.1 ft. 1 ft. 10 ft.

Loss

Frequency counter (during loss, single frequency only)

Resistance fault locate Fault range Resistance to fault at 70° F and no noise Resistance to feet conversion

Noise immunity Outputs Precision tones Tracing tone DTMF

Dial pulse Power source

1.0 dB

7 Vac limit for all frequencies Frequency 404, 1004, 2804 Hz ±1 Hz 39,038 Hz 577.5 Hz

Level 0 dBm ± 0.2 dB 0 dBm ± 1 dB 3 V pk to pk

Impedance @ 600 ohms 135 ohms 100 ohms (Current limited to 6 mA)

Standard

100 ms ON,100 ms OFF

Meets CC1TT Q.23 Standard for frequency and amplitude (±1 Hz 0-10 dBm ±1 dB)

10 pulses per second

60 ms break, 40 ms Make, 600 ms between digits

R-T

Five “C” cell alkaline or rechargeable NiCd batteries (optional)

Typical battery life No backlight With backlight

40 hrs. on fully charged NiCd, 120 hrs. on alkaline 12 hrs. on fully charged NiCd, 35 hrs. on alkaline

Temperature sensor

0° to 140°F (-18° to 60°C)

Harmonic distortion

4000 Hz

0 to 30 Megohms 0 to 7,000 ohms 1 to 99 m 100 to 999 m 1000 to 30000 m

.01 ohm @ 50 ohms 0.1 m 1m 10 m

±(0.001 x RS +2 x 10-8 x RF) ohms

-18° to 60°C (0° to 140°F)

0.56°C (1°F)

±1°C (±2°F)

Frequency

Level

Impedance

Loss Differential 965M 965MC

Common mode 965M 965MC Opens (normal mode) Frequency counter Resistance fault locate Fault range Resistance to fault Resistance to feet conversion

Temperature sensor Outputs Tracing tone 965M 965MC Precision tones 965M 965MC

577.5 Hz 480 Hz

0 dBV 0 dBV

100 ohms (current limited to 8 mA) 100 ohms (current limited to 8 mA)

404, 1004, 2804 Hz ±1 Hz 800, 1020 ±1Hz

0 dBm ± 0.2 dB 0 dBm ± 0.2 dB

@ 600 ohms @ 600 ohms

Variable source

50 Hz to 10 kHz

±1% @ 1 kHz

±1 dB

Power line frequency 965M 965MC Power source Typical battery life

Subscriber Loop Test Products

Net weight kg (lbs.)

Set at 60 Hz User selectable between 50/60 Hz Five “C” cell alkaline batteries Alkaline: 200 hours Nickel-cadmium: 80 hours between charges

309

3

Specifications for the 955M/MC Combination Fault Locator Measurement Function

Range

Phone 800/426 8688 Fax 800/626 0329 www.3M.com/telecom

Size H x W x D cm (in.) Cord length m (ft.)

310

Resolution

Accuracy ±

17.8 x 26.7 x 19.1 (7.0 x 10.5 x 7.5) 1.5 (5)

Net weight kg (lbs.)

3.4 (7.5)

Shipping weight kg (lbs.)

4.8 (10.5)

Operating temperature

-18° to 60°C (0° to 140°F)

Storage temperature

-40° to 74°C (-40° to 165°F)

Relative humidity

0 to 100%

Operating altitude

0 to 5000 m (0 to 15,000 ft.)

Storage altitude

0 to 12000 m (0 to 40,000 ft.)

AC voltage

0 to 75 V 75 to 250 V

0.1 V 1.0 V

0.7 V 3%

DC voltage

0 to 100 V 100 to 350 V

0.1 V 1.0 V

0.5 V 3%

DC current

0 to 110 mA (Zin = 430 ohms)

0.1 mA

0.3 mA

Resistance

0 to 100 Megohms

100 ohms @ 50K ohms

1% @ 50K ohms

0 to 30000 m

3 m @ 500 m

1.5 m ±1% @ 500 m

577.5 Hz 480 Hz

0 dBV @ 100 ohms 0 dBV @ 100 ohms

Current limited to 8 mA Current limited to 8 mA

1004 Hz 800 ±1 Hz, 1020 ±1 Hz

0 dBm ±0.2 dB @ 600 ohms 0 dBm ±0.2 dB @ 600 ohms

0 to 30 Megohms 0 to 7000 ohms 1 to 99 m 100 to 999 m 1000 to 30000 m

.01 ohm @ 50 ohms 0.1 m 1m 10 m

±(0.001 x RS +2 x 10-8 x RF) ohms

-18° to 60°C

0.5°C

±1°C

Outputs Precision tone Tracing tone

Frequency 1004 Hz ±1 Hz 577.5 Hz ±1 Hz

Level 0 dBm ±0.2 dB 6 V pk to pk

Impedance @ 600 ohms Current limited to 8 mA

Variable source (955MC only)

50 Hz to 10 kHz

±1% @ 1 kHz

±1 dB

Opens (normal mode) Trace tone: 955M 955MC Reference tone: 955M 955MC Resistance fault locate Fault range Resistance to fault Resistance to meters conversion

Temperature sensor

Power source Typical battery life

Five “C” cell alkaline batteries Alkaline: 200 hours