TOMORROW’S SOLUTIONS TODAY

www.faiveleytransport.com

References trains – locomotives

2

Pegasus Integrated System CRH1-380 – Zefiro China – high speed train NTV – high speed train EMU V 250 CRH3-380 (380A) – high speed train EMU EJ 671 RGV2N2 – high speed train ÖBB1216 locomotive 109 E three-system locomotive EMU EJ 575 ES60U3 Eurosprinter KTX II – high speed train  SEPTA EMU AGC EMU NAT EMU DMU 219 Bari AC6000 CW locomotive Pendolino 2ES6 Prima FRET locomotive FRET Diesel locomotive

3 6 7 8 9 10 12 13 14 16 17 18 19 20 21 22 23 24 25 26 27

trams

29

CITADIS tram Tram for St. Petersburg Vario LF tram Škoda 14T tram, Prague

30 31 32 33

metro

34

Metro Delhi MNG – Metro Milano M8 Tap Changer  Metro Mexico

35 36 37 38

trolleybuses

39

Trolleybus Škoda TR 24 Pilsen Solaris Trolino 12 Škoda 24 TR, Škoda 25 TR Trolleybuses Riga, Latvia Trolleybuses Venezuela Solaris Trolino 18

40 41 42 44 45 46

1

we make the wheel go round

trains – locomotives Pegasus Integrated System CRH1-380 – Zefiro China – high speed train NTV – high speed train EMU V 250 CRH3-380 (380A) – high speed train EMU EJ 671 RGV2N2 – high speed train ÖBB1216 locomotive 109 E three-system locomotive EMU EJ 575 ES60U3 Eurosprinter

2

KTX II – high speed train SEPTA EMU AGC EMU NAT EMU DMU 219 Bari AC6000 CW locomotive Pendolino 2ES6 Prima FRET locomotive FRET Diesel locomotive

www.faiveleytransport.com

Pegasus Integrated System

trains – locomotives

Faiveley Transport

Classical layout

Length 5m

Pegasus layout

Length 2,3m

3

we make the wheel go round

Pegasus Integrated System Faiveley Transport

switchonic: electronic part (under roof)

pantograph

auxiliary compressor

easyswitch

switchonic: pneumatic part AC protection

AC roof line

4

trains – locomotives

www.faiveleytransport.com

5

we make the wheel go round

CRH1-380 – Zefiro China – high speed train Faiveley Transport Qingdao (QFS), China

pantograph

CX PG

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

6

-25°C to +70°C

Working speed:

380 km/h

Rated current:

500 A (AC)

Rated voltage:

25 kV

www.faiveleytransport.com

NTV – high speed train

trains – locomotives

Alstom Transport, France

pantograph

cX nG 3 kv Purpose:

pantograph

CX NG 25 kV supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Rated current: Working speed:

-25°C to +70°C DC 3 kV 2500 A 250 km/h

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

-25°C to +70°C

Rated voltage:

AC 25 kV

Working speed:

300 km/h

7

we make the wheel go round

EMU V 250 Ansaldobreda, Italy

roof disconnector

roof disconnector

5 OSAD 11

Purpose:

disconnects the circuits of traction vehicles

Operating temperature: Rated voltage:

-30°C to +70°C 25 kV

Maximum voltage:

29,5 kV AC

13 OSAD 7

Purpose:

disconnects the circuits of traction vehicles

Operating temperature: Rated voltage:

25 kV

Maximum voltage:

29,5 kV AC

pantograph

pantograph

AX NG

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Type: Rated current: Working speed:

8

-30°C to +45°C 3/1,5 kV DC 2900 A 140 km/h

-30°C to +70°C

AX NG

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Type: Rated current: Rated speed:

-25°C to +70°C 25 kV AC 800 A 275 km/h

www.faiveleytransport.com

CRH3-380 (380A) – high speed train

trains – locomotives

Faiveley Transport Qingdao (QFS), China

pantograph

CX PG Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Working speed:

-25°C to +70°C 380 km/h

Rated current:

1000 A (AC)

Rated voltage:

25kV

9

we make the wheel go round

EMU EJ 671 ŠKODA Transportation

pantograph

AX NG

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Working speed:

resistor

Rated voltage:

10

1800A (DC) / 1000A (AC)

Rated voltage:

25kV AC / 3kV DC

28 SMD 15 functions as the charging resistor of the capacitor filter of traction vehicles

Operating temperature:

160 km/h

Rated current:

contactor

ORP 47 Purpose:

-30°C to +40°C

Purpose: Operating temperature:

designed to make and break DC and AC circuits -33°C to +45°C

-35°C to + 45°C

Rated current:

400A

3000 V DC

Rated voltage:

3000 V DC

www.faiveleytransport.com

roof disconnector

indicator relay

15 OSAD 7

3 RND 6

functions as the indicator of current system in the traction vehicles

Operating temperature:

-35°C to + 45°C

Rated DC voltage:

3000V DC

Maximum voltage:

4200V DC

disconnecting switch

Purpose: Operating temperature:

SPO 1M4-6L24S6

disconnects the circuits of traction vehicles -33°C to +45°C

Rated voltage:

25kV AC/3000 V DC

Purpose:

Maximum voltage:

29kV AC/4200 V DC

Operating temperature:

contactor

Purpose: Operating temperature:

3000 V

Maximum voltage:

4200 V

11 SMD 32

-33°C to +45°C 800A

Rated voltage:

3000 V DC Purpose:

controller

Operating temperature:

KRD 75

Operating temperature: Rated voltage:

1000 V

Maximum voltage:

1200 V

contactor

2 SMD 34 Purpose: Operating temperature:

functions as the charging resistor of the capacitor filter of traction vehicles

Rated voltage:

400 A

-35°C to +45°C 24V DC (+25%; -30%)

1 ORS 26

Operating temperature:

-30°C to +40°C

controls the traction vehicle

resistor

Purpose:

designed to make and break DC and AC circuits

Rated voltage: Rated current:

Purpose:

600 A

contactor

designed to make and break DC and AC circuits

Rated current:

-33 °C to +45 °C

Rated voltage: Rated current:

4 SVD 14

reverses the circuits of the locomotive

trains – locomotives

Purpose:

designed to make and break DC and AC circuits -30°C to +40°C

Rated current:

300A

Rated voltage:

3000 V AC / 50 Hz

Maximum voltage:

3600 V AC

-35°C to +45°C 3000 V DC

contactor

7 SMD 30 resistor

2 ORS 13 Purpose:

functions as the charging resistor of the capacitor filter of traction vehicles

Operating temperature: Rated DC voltage:

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +40°C

-35°C to +45°C

Rated voltage:

1000 V

3000 V DC

Rated current:

800 A

11

we make the wheel go round

RGV2N2 – high speed train Alstom Transport, France

pantograph

CX PG

Operating temperature: Rated voltage: Type: Rated current: Working speed:

12

roof disconnector

OSAD 14 -25°C to +70°C 1,5 kV DC 2900 A 275 km/h

Purpose: Operating temperature:

disconnects the circuits of traction vehicles -40 °C to +70 °C

Rated voltage:

25 kV AC

Maximum voltage:

29 kV AC

www.faiveleytransport.com

ÖBB1216 locomotive

trains – locomotives

Siemens, Germany

reverser

disconnecting switch

7 PPAD 24

SPO 2+1

Purpose: reverses the circuits  of the locomotive Rated voltage:

3000 V

Rated current:

1200 A

Control voltage:

110 V

reverser

2 PPAD 23

Purpose: grounds the circuits  Purpose: Operating temperature: Control voltage:

reverses the circuits of traction vehicles -30°C to +75°C 110V DC +25% -30%

of traction vehicles Operating temperature: Control voltage:

-30°C to +75°C 110V DC +25% -30%

13

we make the wheel go round

109 E three-system locomotive ŠKODA Transportation, ŠKODA Electric

roof disconnector

reverser

10 OSAD 7

1 PPAD 44

Purpose:

performs the off-load reversing of the electric circuits of traction vehicles

Operating temperature: Purpose:

disconnects and grounds the electric circuits of traction vehicles

Operating temperature: Rated voltage:

14

-35°C to +45°C 25 kV

Rated DC voltage: Rated current: Control voltage:

-30°C to +45°C 3000V DC 1000A 24V DC

www.faiveleytransport.com

resistor

earthing switch

RU 7

Purpose: Purpose:

functions as the charging resistor of the capacitor filter of traction vehicles

Operating temperature:

controller

-35°C to +45°C

Rated voltage:

3 000 V DC

3000 V DC

Max. voltage:

4 000 V DC

disconnecting switch

KRD 75

resistor

SPO5 M4 Purpose:

2 ORS 13

reverses the circuits of the locomotive

Operating temperature:

Purpose:

of traction vehicles Operating temperature:

-35°C to +45°C

Rated voltage:

Purpose:

-40°C to +70°C

functions as the charging resistor of the capacitor filter of traction vehicles

Rated voltage:

3000 V

Operating temperature:

Maximum voltage:

4000 V

Rated DC voltage:

-35°C to +45°C 3000 V DC

controls the traction vehicle

Operating temperature: Rated voltage:

-35°C to +45°C +24V DC (+25%; -30%)

lock system

resistor

indicator relay

ORP 50 Purpose:

ZS R

3 RND 6 functions as the charging resistor

Purpose:

functions as the indicator of current

of the capacitor filter of traction vehicles Operating temperature:

Purpose:

performs safety earthing of the electric circuits

trains – locomotives

ORS 33

forms part of the safety interlocking system of traction vehicles

Operating temperature:

Rated voltage: Maximum voltage:

- 35°C to + 45°C

system in the traction vehicles Operating temperature:

-35°C to + 45°C

3000 V DC

Rated DC voltage:

3000V DC

4,2 kV DC

Maximum voltage:

4200V DC

-35°C to +45°C

Rated voltage:

24 V

Rated current:

150 mA

pantograph

CX NG Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Type: Nominal current: Working speed:

-30°C to +50°C 3/15/25 kV AC/DC 2700 A (3 kV) 220 km/h

15

we make the wheel go round

EMU EJ 575 ŠKODA Transportation

contactor pantograph

AX NG

11 SMD 32 Purpose:

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

16

-30°C to +40°C

Operating temperature:

designed to make and break DC and AC circuits -30°C to +40°C

Rated voltage:

1000 V 1200 V

Rated voltage:

AC 25 kV

Maximum voltage:

Working speed:

160 km/h

Rated current:

400 A

www.faiveleytransport.com

ES60U3 Eurosprinter

trains – locomotives

Siemens, Germany

reverser

10 PPAD 24 Purpose: Operating temperature: Rated voltage: Control voltage:

reverses the circuits of the traction vehicle -35°C to + 45°C 3000 V DC 110 V DC

17

we make the wheel go round

KTX II – high speed train Hyundai Rotem, Korea

controller

KRD 99

controller

2 KRD 69 Purpose: controls the braking of traction vehicles

Purpose:

Operating temperature:

Operating temperature:

Rated voltage:

18

-35°C to +55°C 72 V DC

Rated voltage:

controls the traction, braking and reversing of traction vehicles -35°C to +55°C 72 V DC

www.faiveleytransport.com

SEPTA EMU

trains – locomotives

Mitsubishi Electric, Japan

controller

1 KRD 100 Purpose: Operating temperature: Rated voltage:

controls the traction mode of the vehicle -25°C to +40°C 37,5 V DC

19

we make the wheel go round

AGC EMU Bombardier Transportation, France

controller

KRD 69

pantograph

AX

Purpose: 

designed to control the traction,

braking and reversing of traction vehicles

Operating temperature: Rated voltage:

Purpose:

-25°C to +70°C 72 V DC +25% -30%

from the traction system Operating temperature: Rated voltage:

controller

KRD 70

Purpose:

designed to control the pantographs of traction vehicles

Operating temperature: Rated voltage:

20

-25°C to +70°C 72 V DC +25%, -30%

supplies voltage to the vehicle -25°C to +70°C 25/1,5 kV

www.faiveleytransport.com

NAT EMU

trains – locomotives

Bombardier Transportation, France

pantograph

AX

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Type: Rated current: Working speed:

-25°C to +70°C 1,5/25 kV AC/DC 1800 A/250 A 140 km/h +10%

21

we make the wheel go round

DMU 219 Bari PESA, Poland

controller

KRD 34 Purpose:

controls the traction mode of the traction vehicle

Operating temperature:

controller

KRD 75 Purpose:

controls the traction vehicle

Operating temperature: Rated voltage:

22

-35°C to +45°C 24V DC (+25%; -30%)

-30°C to +40°C

Rated voltage:

24 V ss

Rated current:

1A

www.faiveleytransport.com

AC6000 CW locomotive

trains – locomotives

GE Transportation, USA

reverser

3 PPAD 28 Purpose: Operating temperature: Rated voltage: Control voltage:

reverses the circuits of traction vehicles -40°C to +90°C 1500 V DC 64 V DC, 76 V DC

23

we make the wheel go round

Pendolino

controller

Alstom Ferroviaria

KRD 48

Purpose:

designed to control the speed of traction vehicles

Operating temperature:

-40 °C to +60 °C

Rated voltage:

24 Vss

Rated current:

10 A termický

controller

KRD 49

Purpose:

designed to set the traction force and reverse the direction of travel

roof disconnector

of the traction vehicle

7 OSAD 11

Operating temperature:

-40 °C to +60 °C

Rated voltage:

24 Vss

Rated current:

10 A thermal

earthing switch

RUM 5

Purpose: provides safety earthing of the electric Purpose: Operating temperature: Rated voltage: Maximum voltage:

24

disconnects the circuits of traction vehicles -30°C to +70°C 25 kV 29,5 kV AC

power circuits of traction vehicles Operating temperature:

-25 °C to +70 °C

Nominal voltage:

3000 V DC

Maximum operating voltage:

4000 V DC

www.faiveleytransport.com

2ES6

trains – locomotives

Sinara, Russia

pantograph

SX 2100

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Maximum voltage: Working speed:

-50°C to +60°C 3000 V 4000 V 140 km/h

25

we make the wheel go round

Prima FRET locomotive

controller

Alstom Transportn,France

KRD 55

Purpose:

controls the traction and braking modes of traction vehicles

Operating temperature:

-25 °C to +75 °C

Rated voltage:

110 V DC

Rated current:

10 A

controller

KRD 46

Purpose:

controls the traction and braking modes of traction vehicles

Operating temperature:

roof disconnector

OSAD 14

-40 °C to +70 °C

battery containers

FRET

Purpose: disconnects the circuits of traction vehicles Operating temperature:

-40 °C to +70 °C

Rated voltage:

25 kV AC

Maximum voltage:

29 kV AC

pantograph

SX NG Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: -25°C to +45°C Rated voltage: Working speed:

26

15/25 kV 140 km/h

www.faiveleytransport.com

FRET Diesel locomotive

trains – locomotives

Alstom Transportn,France

controller

controller

KRD 72

Purpose:

controller

KRD 55

designed to control the traction and

Purpose:

KRD 73

designed to control the braking

braking modes of traction vehicles Operating temperature:

-25°C to +75°C

Rated voltage:

24V DC

Rated current:

10A thermal

of traction vehicles Operating temperature: Rated voltage: Rated current: :

-25°C to +75°C

Purpose:

designed to control the horn

Operating temperature:

-25°C to +75°C

110 V DC

Rated voltage:

24V DC

10 A thermal

Rated current:

10A thermal

27

we make the wheel go round

28

www.faiveleytransport.com

trams CITADIS tram Tram for St. Petersburg Vario LF tram Škoda 14T tram, Prague

29

we make the wheel go round

CITADIS tram Alstom Transportation, France

controller

controller

1 KRD 57

2 KRD 57

5 KRD 57

Purpose: designed to control the traction, braking

Purpose: designed to control the traction, braking

Purpose: designed to control the traction, braking

and emergency braking modes of the tram

and emergency braking modes of the tram

and emergency braking modes of the tram

Operating temperature: Rated voltage:

30

controller

-25°C to +70°C 24 Vss

Operating temperature: Rated voltage:

-25°C to +70°C

Rated voltage:

24 V DC

24 V DC

Rated current:

10 A

www.faiveleytransport.com

Tram for St. Petersburg

trams

PTMZ, Russia

controller

KRD 115

Purpose: Operating temperature:

controls the traction vehicle -30°C to + 60°C

Rated voltage:

750 Vss

Rated current:

450 A

main switch

VPD 14

pantograph

EPDE 16-2600 Purpose: Purpose:

the EPDE 16–2600 current collectors are designed for trams

Operating temperature:

provides overcurrent protection of the vehicle -30°C to + 60°C

Rated voltage:

600 V DC / 750 V DC

Rated voltage:

750 VSS

Rated current:

1000 A

Rated current:

450 A

31

we make the wheel go round

Vario LF tram PRAGOIMEX

controller

reverser

KRD 56

2 PPAD 37

pantograph

EPDE 11-2600 Purpose: reverses the circuits of traction vehicles Purpose:

designed to control traction vehicles

32

Operating temperature:

-30°C to +40°C

Rated voltage:

Rated voltage:

24 V DC

Rated current:

Rated current:

1A

Operating temperature:

Control voltage:

-25°C to +50°C

Purpose: designed for vehicles supplied from the

1000 V

traction system

1000 A

Rated voltage:

600 V DC / 750 V DC

24 V DC

Rated current:

1 500 A

www.faiveleytransport.com

Škoda 14T tram, Prague

trams

ŠKODA Transportation

reverser

PPAD 51

Purpose:

designed to connect/disconnect and to ground the main supply from the current collector of the tram and to ground the auxiliary drives supply

Operating temperature: Rated voltage: Rated current: Control voltage:

-25°C to +50°C 1000 V 1000 A 24 V DC

33

we make the wheel go round

metro Metro Delhi MNG – Metro Milano M8 Tap Changer Metro Mexico

34

www.faiveleytransport.com

Metro Delhi

metro

Bombardier Transportation, India

pantograph

LX 1800

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: Rated voltage: Type: Working speed:

0°C to +50°C 25 kV AC 85 km/h

35

we make the wheel go round

MNG – Metro Milano FIREMA Transporti, Italy

pantograph

LX 1100 FIREMA Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature: -25°C to +45°C (cat. T3) Rated voltage: Rated current: Maximum current:

36

750V DC to 1500V DC 800 A to 1600 A 1450 A to 2850 A

www.faiveleytransport.com

M8 Tap Changer

metro

Mitsubishi Electric, Japan

container

1 BPS 27 Purpose:

contains a reverser designed to reverse the circuits of traction vehicles

Operating temperature: Rated voltage:

-40°C to +55°C 12,5 kV / 25 kv

37

we make the wheel go round

Metro Mexico CAF, S.A., Spain

controller

2 KRD 108 Purpose:

designed to control the traction and braking modes of traction vehicles

Operating temperature: Rated voltage:

38

-10°C to +45°C 72 V DC

www.faiveleytransport.com

trolleybuses Trolleybus Škoda TR 24 Pilsen Solaris Trolino 12 Škoda 24 TR, Škoda 25 TR Trolleybuses Riga, Latvia Trolleybuses Venezuela Solaris Trolino 18

39

we make the wheel go round

Trolleybus Škoda TR 24 Pilsen ŠKODA Electric

contactor

contactor

7 SMD 30

5 SMD 33

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature: Rated voltage:

1000 V

Rated current:

800 A

trolleybus current collector

TSS 2.5 Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

40

-30°C to +60°C

Rated voltage:

750 Vss

Rated current:

600 A

-30°C to +40°C

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +65°C

Rated voltage:

750 V DC

Rated current:

40 A

www.faiveleytransport.com

Solaris Trolino 12

trolleybuses

Trolleybuses for municipal transport companies

trolleybus current collector

TSS 2.1 Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

-30°C to +40°C

Rated voltage:

750 V ss

Rated current:

600 A

main switch

VPD 14 Purpose:

provides overcurrent protection of the vehicle

Operating temperature:

-30°C to +60°C

Rated voltage:

750 V ss

Rated current:

450 A

contactor

contactor

7 SMD 30

5 SMD 33

Purpose: designed to make and break DC and AC circuits in traction vehicles

Purpose: designed to make and break DC and AC circuits in traction vehicles

Operating temperature:

Operating temperature:

-30°C to +40°C

-30°C to +65°C

Rated voltage:

1000 V

Rated voltage:

750 V DC

Rated current:

800 A

Rated current:

40 A

41

we make the wheel go round

Škoda 24 TR, Škoda 25 TR Škoda Electric

contactor

10 SMD 32

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +60°C

Rated voltage:

750 V DC

Rated current:

400 A

Maximum vypínací proud:

800 A

trolleybus current collector

TSS 2.1 resistor

ORS 30

Purpose:

supplies voltage to the vehicle from the traction system

Purpose: Operating temperature: Rated voltage:

42

series, charging and discharging resitors

Operating temperature:

-30°C to +40°C

-35°C to +45°C

Rated voltage:

750 V ss

3000 V DC

Rated current:

600 A

trolleybuses

www.faiveleytransport.com

contactor

5 SMD 33

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +65°C

Rated voltage:

750 V DC

Rated current:

40 A

contactor

7 SMD 30

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +40°C

Rated voltage:

1000 V

Rated current:

800 A

43

we make the wheel go round

Trolleybuses Riga, Latvia ŠKODA Electric

contactor

7 SMD 30

Purpose: designed to make and break DC and AC circuits in traction vehicles Operating temperature:

-30°C to +40°C

Rated voltage:

1000 V

Rated current:

800 A

contactor

5 SMD 33

trolleybus current collector

TSS 2.6

Purpose: supplies voltage to the vehicle

Purpose: designed to make and break DC and AC

from the traction system Operating temperature:

44

circuits in traction vehicles -40°C to +60°C

Operating temperature:

-30°C to +65°C

Rated voltage:

750 V ss

Rated voltage:

750 V DC

Rated current:

600 A

Rated current:

40 A

www.faiveleytransport.com

Trolleybuses Venezuela

trolleybuses

Bombardier Transportation, Spain

trolleybus current collector

TSS 9.1 Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

-30°C to +50°C

Rated voltage:

750 V ss

Rated current:

600 A

45

we make the wheel go round

Solaris Trolino 18 Municipal transport Salzburg, Austria

trolleybus current collector

TSS 10.2

main switch

VPD 14

Purpose: Operating temperature:

Purpose:

supplies voltage to the vehicle from the traction system

Operating temperature:

-40°C to +40°C

Rated voltage:

750 V ss

Rated current:

600 A

provides overcurrent protection of the vehicle

contactor

-30°C to +60°C

Rated voltage:

750 V ss

Rated current:

450 A

2 SMD 33

contactor

SMD 32

Purpose: Operating temperature:

46

designed to make and break DC circuits -30°C to +60°C

Purpose:

designed to make and break DC circuits in traction vehicles

Operating temperature:

-30°C to +65°C

Rated voltage:

750 V ss

Rated voltage:

750 V DC

Rated current:

400 A

Rated current:

40 A

Faiveley Transport Australia Ltd • Rosehill • +61 288 6347 00 • Australia + Faiveley Transport Do Brasil S/A • São Paulo • +55 (11) 6889-6001 • Brazil + Faiveley Transport Canada • Châteauguay • +18 64 27 75 00 0 • Canada + Shanghai Faiveley Railway Technology Co. Ltd. • Shanghai • +86 21 33718866 • China + Faiveley Transport Lekov • Blovice • +420 379 207 111 • Czech Republic + Faiveley Transport Pilsen • Nyrany • +420 379 411 520 540 • Czech Republic + Faiveley Transport Tours • Tours • +33 2 47 32 55 55 • France + Faiveley Transport NSF • Neuville-en-Ferrain • +33 (0)3 20 45 65 46 • France + Faiveley Transport Leipzig GmbH & Co. KG • Schkeuditz • +49 34204 85 300 • Germany + Faiveley Transport India Ltd. • Harita, Hosur • +91 4344 276 761 • India + Faiveley Transport Italia S.p.A. • Piossasco • +39 (0)11 90 44 1 • Italy + Faiveley Transport Polska • Poznan • +48 61 653 64 11 • Poland + Faiveley Transport Russia • Vsevolozhsk City • +7 812 676 59 80 • Russia + Faiveley Transport Korea • Seoul • +82 2564 03 25 • South Korea + Faiveley Transport Ibérica S.A. • Tarragona • +34 977 011000 • Spain + Faiveley Transport Nordic • Landskrona • +46 418 544 00 • Sweden + Faiveley Transport Switzerland – Urs Dolder AG • Hägendorf • +41(0) 62 216 33 88 • Switzerland + Faiveley Transport Tamworth • Tamworth • +44 1 827 308430 • UK + Faiveley Transport Ellcon National • Greenville • +1 864 277 5000 • USA +

++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++ ++++++++