Residential Home Inspection Report Property Address: City/State:

2002 Anywhere Street Model City, USA

Client:

Mr. & Mrs. Home Buyer

Type of Inspection: Date of Inspection:

General Home Inspection September 17, 2002

Contact Person:

Buyer's Agent

Inspector:

Ronald A. Werder

Inspector's Signature: File #:

02359

General Comments Regarding This Inspection NOTE: The results from the radon test will follow under a separate cover.

Werder Home Inspections, Inc.

819 Kandiyohi Avenue Willmar, MN 56201 (320)231-1614 [email protected] Certified Member #2204743 American Society of Home Inspectors

INSPECTION AGREEMENT PROPERTY ADDRESS: 2002 Anywhere Street Model City, USA

CITY, STATE:

TYPE OF INSPECTION: General Home Inspection CLIENT:

Mr. & Mrs. Home Buyer

INSPECTION DATE:

September 17, 2002

INSPECTOR: Ronald A. Werder

ASHI MEMBER #: 204743

The Inspector listed above conducts this inspection , to the extent feasible, based on Standards of Practice and Code of Ethics set forth by the American Society of Home Inspectors (a copy is available upon request). A written report will follow the field inspection. Each inspection includes only those items, systems, and components expressly identified in the written report. This inspection is essentially visual, it is not technically exhaustive, and does not imply that every defect was found. Latent, concealed, or inaccessible defects & problems are excluded from this inspection. Floor coverings, furniture and personal belongings are not disturbed during the inspection. The equipment & appliances included in this inspection are tested for response to normal controls only, when possible. The equipment and appliances included in this inspection are not dismantled, other than normal service panels which can be freely and easily removed. A carbon monoxide test will be conducted inside the home measured in parts per million. This test is limited in scope and is restricted to the conditions inside the house at the time of the inspection. The conditions inside the house can and will change. The heating appliance heat exchanger cannot be viewed without dismantling the unit. A specialist in heating appliances who is trained in dismantling the unit should be retained if the heat exchanger is desired to be visually inspected. The written report is an overview of this inspection and supersedes the inspector's oral comments. This inspection does not include governmental code compliance. This inspection is intended to report whether a system, item, or component thereof is reasonably operating or functioning at the time of the inspection only. This home inspection does not address the possible presence of radon gas, lead paint or solder, asbestos, toxic or flammable chemicals, or other harmful or environmentally unsafe substances. The possible presence of such items should be identified by a specialist in the detection of these substances. An inspection of private waste disposable systems (such as septic systems) are not included in this home inspection. Also, this report does not include an inspection for wood destroying insects &/or pests. Specialists in these fields should be contacted if these inspections are desired. The radon gas screening test (optional) reports on the level of radon gas that the testing device was exposed to during its exposure in the home. The inspector assumes no liability for the accuracy of this report based on the environmental conditions present at the time of the inspection. To the extent feasible, the testing device will be placed following EPA protocols. The inspector assumes no liability for the cost of repairing or replacing any unreported defects or conditions, either current or arising in the future, or any consequential damages, bodily injury, or property damage of any nature that may occur.

IMPORTANT: This inspection and report are performed & prepared for the sole use of the listed client. The inspector has no financial or business interest in this property. NO EXPRESSED OR IMPLIED WARRANTY IS GIVEN CONCERNING THE BUILDINGS AND EQUIPMENT OR THEIR FUTURE USEFULNESS. The inspector assumes no liability to third parties in connection with this inspection and written report.

Werder Home Inspections, Inc.

819 Kandiyohi Avenue Willmar, MN 56201 [email protected] (320)231-1614 Fax (320)235-2284 INSPECTION AGREEMENT

Page 2 of 17

GENERAL INFORMATION & CONDITIONS GENERAL INFORMATION REGARDING THIS INSPECTION HOUSES FACES: East

AREA:

ESTIMATED AGE: 25 years

STREET TYPE:

with addition BUILDING TYPE: One Family, Wood Framed

WATER SOURCE: Public Water Supply

NUMBER OF STORIES: One Story

SEWAGE DISPOSAL: Public Waste Disposal

SPACE BELOW GRADE: Basement

GARAGE:

Town Paved Through Street

Attached, 1 stall

GENERAL CONDITIONS PRESENT AT TIME OF INSPECTION UTILITY STATUS: All On SOIL CONDITION: Dry OCCUPANCY:

Occupied

WEATHER: Clear PEOPLE PRESENT: Client, Client's Agent

65 degrees

DEFINITIONS Satisfactory: Item is typical for age. Satisfactorily performing its intended function. Marginal: Attention should be given to this item as it is performing only part of its intended function, and condition indicates preventative maintenance is desired.

UNSATISFACTORY: Item is not adequately performing its intended function &/or has an UNSAFE condition.

Not Applicable: Item does not apply to this structure. Not Visible: Item was not located or was not visible for inspection. Comment: Informational remarks regarding the particular item.

TABLE OF CONTENTS COVER PAGE INSPECTION AGREEMENT GENERAL INFORMATION GROUNDS EXTERIOR ROOF STRUCTURE PLUMBING CENTRAL HEATING 2nd CENTRAL HEATING (if applicable) CENTRAL COOLING & SUPPLEMENTARY HEATING 2nd CENTRAL COOLING (if applicable) ELECTRICAL APPLIANCES INTERIOR ROOMS INTERIOR ROOMS, cont. INTERIOR ROOMS, cont. ATTIC GARAGE OUTBUILDING (if applicable) Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 9b Page 10 Page 10b Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 17b

R

GENERAL INFORMATION Page 3 of 17

GROUNDS GENERAL COMMENTS REGARDING THE GROUNDS

ITEM / TYPE

CONDITION / REMARKS

1. SIDEWALKS

Satisfactory

concrete

2. DRIVEWAY

Satisfactory

Concrete

3. PATIOS

Not Applicable

4. GRADE & DRAINAGE lot is basically flat

Marginal Low grade exists next to the foundation in random areas around the structure. Add soil and regrade to promote drainage away from the structure.

5. RETAINING WALLS

Not Applicable

6. DECKS

Not Applicable

7. PORCHES/BALCONIES

Not Applicable

8. VEGETATION (as effects structure only)

Satisfactory

Shrubs Mature trees

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

GROUNDS Page 4 of 17

EXTERIOR GENERAL COMMENTS REGARDING THE EXTERIOR

ITEM / TYPE

CONDITION / REMARKS

1. EXTERIOR WALL COVERING

Satisfactory

vinyl lap siding

2. SOFFITS/FASCIA/TRIM

Satisfactory

metal clad

3. HOUSE WINDOWS

Satisfactory

sliders Composition: vinyl

4. STORMS & SCREENS integral screens

Comment The screens were missing or not installed from some of the windows at the time of the inspection.

5. BASEMENT WINDOWS

Satisfactory

wood, awning type

6. ENTRY DOORS

Satisfactory

Number of entry doors: One metal insulated

7. PATIO DOORS

Not Applicable

Number of patio doors:

8. PAINT & FINISHES (all areas)

Satisfactory

paint

9. FOUNDATION (exterior view only)

Satisfactory

concrete block

10. STOOPS/STAIRS/STEPS

Satisfactory

concrete steps

11. CAULKING

Satisfactory

12. EXTERIOR HOSE BIBBS

Satisfactory

two Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

EXTERIOR Page 5 of 17

ROOF GENERAL COMMENTS REGARDING THE ROOF PORTION OF ROOF VIEWED: all METHOD OF VIEWING: roof was accessed STYLE OF ROOF: Gable

SLOPE OF ROOF: Medium

ITEM / TYPE

CONDITION / REMARKS

1. SLOPED ROOFING MATERIAL

Type of Roof Covering:

Reported age of roof covering:

Satisfactory

asphalt shingles 11 years

Normal Life Span:

20 years Estimated Remaining Useful Life: 7-9 years Number of Layers: one

2. FLAT ROOFING MATERIAL

Not Applicable

Type of Roof Covering:

Reported age of roof covering: Normal Life Span: Estimated Remaining Useful Life: Number of Layers:

3. ROOF STRUCTURE

Satisfactory

medium slope, gable style

4. FLASHINGS/VALLEYS metal flashings

Marginal The flashing around the electrical mast is lifting. Secure and seal the flashing to prevent leakage.

5. APPLIANCE COMBUSTION FLUES

Satisfactory

metal flue

6. CHIMNEYS

Not Applicable

Number of chimneys:

7. GUTTER SYSTEM

Satisfactory

aluminum

8. MISC. ITEMS (skylights, antennas, etc.)

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

Not Applicable

R

ROOF Page 6 of 17

STRUCTURE GENERAL COMMENTS REGARDING THE STRUCTURE TYPE OF SPACE BELOW GRADE:

Basement

ACCESS TO SPACE BELOW GRADE: Interior stairway

ITEM / TYPE

CONDITION / REMARKS

1. BASEMENT STAIRS

Satisfactory

open, wood stairs

2. VISIBLE FOUNDATION WALLS

Satisfactory

concrete block

3. BASEMENT FLOOR

Satisfactory

concrete

4. BEARING BEAMS &/or WALLS

Satisfactory

wood bearing wall

5. SUPPORT COLUMNS/PIERS

Not Visible

6. FIRST FLOOR STRUCTURE

Satisfactory

wood joists plywood sheathing

7. INDICATIONS OF MOISTURE stains

Marginal Indications of past basement water entry were noted in random areas. Improving the exterior drainage around the foundation, along with maintaining the gutter/down spout system, should help minimize basement water entry. Also, a "Beaver" water mitigation system has been installed to help with water entry.

8. FLOOR DRAINAGE

Satisfactory

Number of floor drains: one Number of sump pits: one Sump pumps discharge to: exterior

9. RELATED CRAWL SPACE ITEMS

Not Applicable

10. VISIBLE INSULATION (in area below grade)

Satisfactory

fiberglass batt in rim joist spaces

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

STRUCTURE Page 7 of 17

PLUMBING GENERAL COMMENTS REGARDING THE PLUMBING WATER SUPPLY FROM: Public Water Supply WASTE DISPOSAL TYPE: Public Waste Disposal

ITEM / TYPE

CONDITION / REMARKS

1. MAIN WATER SERVICE PIPE

Satisfactory

Main shut-off valve at: water meter Main supply pipe material: copper

Satisfactory

2. WATER SUPPLY PIPING copper

3. WASTE/DRAIN/VENT PIPING

Satisfactory

ABS plastic

Satisfactory

4. MAIN WASTE CLEAN-OUT located at the base of the main waste stack

5. WATER HEATER

(2nd water heater if applicable)

Satisfactory

MAKE:

AO Smith SERIAL #: GB94-1751959 natural gas FUEL: SIZE:

40 gallons

LOCATION: basement ESTIMATED AGE: 8 years

6. WATER HEATER VALVES

Satisfactory

Temperature & Pressure Relief Valve? Yes Cold Water Shut Off Valve? Yes

Marginal

7. WATER HEATER VENTING metal flue pipe, joins heating flue

At start-up, combustion products were back drafting from the hood above the water heater. This remained after several minutes of operation. This should be checked regularly and the back-drafting corrected if continues. The carbon monoxide levels were low.

8. FUEL SUPPLY LINES ( visible areas)

Satisfactory

black steel natural gas lines

Satisfactory

9. PLUMBING FIXTURES (unfinished areas ) laundry tub

Satisfactory

10. LAUNDRY CONNECTIONS

Location: basement

Dryer Fuel: electric Dryer Vents to: exterior Washer Discharge: drain stand tube

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

PLUMBING Page 8 of 17

CENTRAL HEATING GENERAL COMMENTS REGARDING CENTRAL HEATING SYSTEM DESIGN: forced air FUEL:

natural gas

ITEM / TYPE

CONDITION / REMARKS Comment

1. HEATING APPLIANCE MAKE: MODEL #:

Heil VG-105AT-1CR

SERIAL #:

H63879681

This unit is approaching the end of its normal design life. It's remaining life cannot be predicted. The carbon monoxide tests were negative and within normal levels at the time of the inspection. Suggest plans begin to upgrade the furnace due to its age.

SIZE:

105,000 btu/hr LOCATION: basement BLOWER/PUMP: direct drive blower APPLIANCE CONTROLS: high limit/fan control DRAFT REGULATOR: integral draft hood ESTIMATED AGE: 25 years

2. DISTRIBUTION PIPES/DUCTS

Satisfactory

sheet metal ducts

NOTE: due to the limitations of a visual inspection, the size/adequacy of the distribution system (duct/pipes) cannot be fully determined. Contact a qualified heating contractor if an adequacy test is desired.

3. THERMOSTAT(s)

Satisfactory

Number of Thermostats: one Type: regular Locations: central first floor Number of Zones: one

4. AIR FILTER(s)

Satisfactory

Number of filters: one disposable filter

5. EXPOSED FLUE PIPES/AIR SUPPLY

Satisfactory

metal flue pipe vents to dedicated metal flue, out the roof

6. CENTRAL HUMIDIFIER

Not Applicable

MAKE:

7. AIR-TO-AIR HEAT EXCHANGER

Not Applicable

MAKE:

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

CENTRAL HEATING Page 9 of 17

CENTRAL COOLING GENERAL COMMENTS REGARDING CENTRAL COOLING TYPE OF SYSTEM:

electric refrigeration

VIEWED OPERATING ?

Yes

ITEM / TYPE

CONDITION / REMARKS Marginal

1. CENTRAL COOLING APPLIANCE MAKE:

The temperature drop across the air conditioner coil was 8-10 degrees, where normal is 15-20 degrees. This is improper cooling. Contact a qualified technician for repairs.

Heil

MODEL #: 700029 SERIAL #: n/v ESTIMATED AGE: undetermined

2. DISTRIBUTION & CONTROLS

Satisfactory

same as the heating system

3. SUPPLEMENTARY COOLING

Not Applicable

SUPPLEMENTARY HEATING GENERAL COMMENTS REGARDING SUPPLEMENTARY HEATING

ITEM / TYPE

CONDITION / REMARKS Not Applicable

4. WOOD BURNER MAKE: MODEL #: UNIT LISTED ? LOCATION:

Not Applicable

5. AUXILIARY HEAT MAKE: TYPE: LOCATION

Not Applicable

6. AUXILIARY HEAT MAKE: TYPE: LOCATION:

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

CENTRAL COOLING/SUPPLEMENTARY HEATING Page 10 of 17

ELECTRICAL GENERAL COMMENTS REGARDING THE ELECTRICAL

ITEM / TYPE

CONDITION / REMARKS

1. MAIN SERVICE SIZE

Satisfactory

MAIN SERVICE SIZE: 120/240 volts, 200 amps overhead SERVICE TYPE: SERVICE GROUND:

main water pipe

2. MAIN SERVICE PANEL

Satisfactory

LOCATION: basement MAIN SERVICE DISCONNECT(s): breaker MAIN DISCONNECT(s) LOCATION: main panel MAIN SERVICE CONDUCTOR: aluminum

3. 120 VOLT CIRCUITS (main panel)

Satisfactory

CIRCUIT DISCONNECTS: breakers CIRCUIT CONDUCTORS: copper Number of 120 volt circuits: 15

4. 240 VOLT CIRCUITS (main panel)

Satisfactory

CIRCUIT DISCONNECTS: breakers CIRCUIT CONDUCTORS: copper Number of 240 volt circuits: 3

5. ELECTRICAL SUB-PANELS

Not Applicable

NUMBER OF SUB-PANELS: LOCATION(s):

6. 120 VOLT CIRCUITS (sub-panels)

Not Applicable

CIRCUIT DISCONNECTS: CIRCUIT CONDUCTORS: Number of 120 volt circuits:

7. 240 VOLT CIRCUITS (sub-panels)

Not Applicable

CIRCUIT DISCONNECTS: CIRCUIT CONDUCTORS: Number of 240 volt circuits:

8. GFCI's (Ground Fault Circuit Interrupters) TYPE: breaker LOCATION(s): main panel

Comment A limited number of ground fault circuit interrupters were present. Consider installing them in all wet areas such as the bathrooms, kitchen, garage, and the exterior to reduce the risk of electrical shock.

9. VISIBLE WIRING IN UNFINISHED AREAS

Satisfactory

romex cable

10. EXTERIOR WIRING

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

Satisfactory

R

ELECTRICAL Page 11 of 17

APPLIANCES GENERAL COMMENTS REGARDING THE APPLIANCES

ITEM / TYPE

CONDITION / REMARKS

1. RANGE

Satisfactory

Make: Maytag Type: freestanding, electric

2. COOKTOP

Not Applicable

Make: Type:

3. BUILT-IN OVEN

Not Applicable

Make: Type:

4. KITCHEN EXHAUST

Satisfactory

Make: Nautilus Type:

vented

5. MICROWAVE

Not Applicable

Make: Type:

6. DISHWASHER

Not Applicable

Make: Type:

7. GARBAGE DISPOSER

Satisfactory

Make: Master Plumber Type:

standard

8. REFRIGERATOR

Satisfactory

Make: Amana Type:

standard

9.

Not Applicable

Make: Type:

10.

Not Applicable

Make: Type:

11.

Not Applicable

Make: Type:

12.

Not Applicable

Make: Type: Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

APPLIANCES Page 12 of 17

INTERIOR ROOMS FORMAT FOR INSPECTING THE INTERIOR ROOMS Please note that multiple ratings can occur in one room. If such is the case, all ratings will be identified in the rating section for that particular room and all remarks will be referenced according to its rating. If no deficiencies were noted, then the room will be rated "Satisfactory". Cosmetic items are excluded from this report. All information is based on observations that are clear to view. Personal belongings, storage, furniture, etc. are not moved for inspection purposes. The following items are checked in each room. :wall, ceiling, and floor surfaces

:presence of heat source

:steps, stairways, balconies, and railings

:presence of installed cooling source

:plumbing fixtures, faucets, & visible supply & waste/ drain/vent piping

:representative cabinets and counters

:representative number of windows, doors, hardware

:functional water flow at selected fixtures

:operation of a representative number of installed lighting fixtures, switches, outlets, and other installed electrical components, including GFCI(s)

GENERAL REMARKS REGARDING THE INTERIOR ROOMS

ITEM / TYPE

CONDITION / REMARKS

1. FIREPLACES

Not Applicable

Number of fireplaces: Locations: Types:

ROOM

LOCATION

2. KITCHEN (incl. eat-in dining)

SE 1st floor

3. FORMAL DINING ROOM

Satisfactory

Not Applicable

4. LIVING ROOM

5. FAMILY ROOM

CONDITION

NE 1st floor

Central basement

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

Satisfactory

Satisfactory

R

INTERIOR ROOMS Page 13 of 17

INTERIOR ROOMS, cont. ROOM

LOCATION

CONDITION

6. BATHROOM

Central basement

Satisfactory

7. BATHROOM

Central 1st floor

Satisfactory

8. BATHROOM

Not Applicable

9. HALLWAYS/STAIRWAYS

Satisfactory

10. BEDROOM

NW 1st floor

Satisfactory

11. BEDROOM

West 1st floor

Satisfactory

12. BEDROOM

SW 1st floor

Satisfactory

13. BEDROOM

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

Not Applicable

R

INTERIOR ROOMS, Cont. Page 14 of 17

INTERIOR ROOMS, cont. ROOM

LOCATION

14. SPARE ROOM

NW basement

15.

CONDITION Satisfactory

Not Applicable

16.

Not Applicable

17.

Not Applicable

18.

Not Applicable

19.

Not Applicable

20.

Not Applicable

21.

Not Applicable

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

INTERIOR ROOMS, Cont. Page 15 of 17

ATTIC GENERAL REMARKS REGARDING THE ATTIC The attic was viewed from the hatch opening. The inspection was restricted to those areas clear to view from the hatch opening.

ITEM / TYPE

CONDITION / REMARKS

1. ATTIC ACCESS

Satisfactory

LOCATION:garage wall hatch TYPE:

2. ROOF STRUCTURE

Satisfactory

wood trusses, plywood sheathing

3. EXHAUST FAN DUCTS

Satisfactory

bathroom exhaust fan duct kitchen exhaust fan duct

4. CHIMNEYS/FLUES

Satisfactory

metal flue

5. ELECTRICAL WIRING

Satisfactory

romex cable

6. PLUMBING VENTS

Satisfactory

ABS plumbing vents

7. ATTIC INSULATION (main attic) Depth: 6" loose fill cellulose

Comment The insulation depth was minimal for a northern climate. Suggest adding more to achieve an insulating value of R38 - R44 for energy conservation.

Not Applicable

8. ATTIC INSULATION (other attic areas) Depth:

9. ATTIC VENTILATION

Satisfactory

soffit vents roof vents

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

ATTIC Page 16 of 17

GARAGE GENERAL COMMENTS REGARDING THE GARAGE TYPE OF GARAGE:

Attached, 1 stall

ITEM / TYPE

CONDITION / REMARKS

1. EXTERIOR COMPONENTS

Satisfactory

same as the house

2. WALL STRUCTURE

Satisfactory

wood framed

3. FOUNDATION

Satisfactory

concrete block

4. FLOOR

Satisfactory

concrete

5. ROOF STRUCTURE

Satisfactory

wood trusses, plywood sheathing

6. ROOFING MATERIAL

Satisfactory

same as the house Estimated age of roofing: Estimated remaining useful life:

7. VEHICLE DOORS

Satisfactory

# of doors: 1 Type: sliding overhead Material: fiberglass

8. VEHICLE DOOR OPENERS

Satisfactory

# of openers: 1 Make(s): Franz with auto reverse

9. ELECTRICAL

Satisfactory

Sub-panel/Sub-feed: Circuit connectors: Circuit conductors: Number of 120 volt circuits:

--240 volt:

10. PLUMBING/HEATING

Not Applicable

11. FIRE RESISTIVE WALLS/DOORS* *APPLIES TO ATTACHED GARAGE ONLY drywall on common house wall

UNSATISFACTORY SAFETY CONCERN: The door between the house and garage was not fire-resistant. Install a solid wood or metal door for safety considerations.

Werder Home Inspections, Inc. prepared this Home Inspection Report for the sole use of Mr. & Mrs. Home Buyer

R

GARAGE Page 17 of 17