Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement SERIES 544 Laser Scan Micrometer LSM-902/6900 Optional Accessories • Narr...
Author: Ashlyn Mosley
39 downloads 3 Views 3MB Size
Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer LSM-902/6900

Optional Accessories

• Narrow range accuracy of ±(0.3+0.1 D)μm for high precision measurement. • Ultra-high repeatability of ±0.05μm. • The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900).

• Non-contact laser-based measuring system, mainly for outside diameter measurement. Suitable for delicate or moving workpieces. • Accuracy of ±0.5μm in the ø0.1 - ø25mm range can be achieved. It is highly suitable suited for pin gage measurement.

G

(Refer to page G-44 for details.) • Standard calibration gage set (ø1.0, ø25.0) : No.02AGD180 • Workstage : No.02AGD270 • Adjustable workstage : No.02AGD280 • Digimatic code output unit (2-ch) : No.02AGC840 • 2nd I/O analog interface unit : No.02AGC880 • BCD interface unit : No.02AGC910 • Printer & cable set (100V AC C-type plug) : No.02AGD600A • Printer & cable set (120V AC C-type plug) : No.02AGD600B • Printer & cable set (230V AC C-type plug) : No.02AGD600C • Printing paper TP411-28CL / 1Pack = 10pcs : No.223663 • Digimatic code output cable : No.936937 • Foot switch : No.937179T

SPECIFICATIONS

Set Order No. 544-495* 544-496* Measuring unit Type mm inch/mm Measuring range 0.1 to 25mm (.004 - 1.0") 0.01 to 10μm (selectable) (.000001 - .0005") Resolution Repeatability*1 ±0.05μm (±.000002") Whole range ±0.5μm (±.000020") Accuracy*2 ±(0.3+0.1 D) [D:mm]*5 (20°C) Small range ±(.000012+.001 D) [D:inch] ±0.5μm (±.000020") Positional error*3 ±1.5×25mm (±0.6x1.0") Measuring range*4 Scanning rate 800 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 56m/s (2240"/sec) 0 to 40°C Operating Temperature environment Humidity RH 35 to 85% (no condensation) *1: Determined by the value of ±2 ( : standard deviation) when measuring ø25mm at the interval of 1.28 sec. (average 1024 times). *2: At the center of the measuring range. *3: An error due to variation in workpiece position either in the optical axis direction or in the scanning direction. *4: The area given by [optical axis direction]×[scanning direction] *5: D=Difference in diameter between the master gage and workpiece (Unit: mm) Note: To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE.

Display unit

16-digit plus 11-digit fluorescent display, and guide message LED Segment 1 to 7 (1 to 3, transparent) or 1 to 255 edges Averaging Arithmetic average: per 1 to 2048/ Moving times average: per 32 to 2048 Selection from "target value + tolerance", "lower Judgment tolerance + upper tolerance", or "7 classes multilimit tolerance zone". Measurement Standby, Single measurement, Continuous mode measurement Statistical Maximum, Minimum, Average, Dispersion, (S.D) analysis External dimensions 335 (W)×134 (H)×250 (D)mm Power supply 100 - 240 V AC ±10%, 50W, 50/60Hz Standard I/F RS-232C, Analog I/O code output unit (2-ch), 2nd I/O analog Optional I/F Digimatic I/F, BCD I/F Operating environment 0 to 40°C, RH 35 to 85% (no condensation) Nominal setting, sample setting, selection of unnecessary digits, transparent object measurement, automatic measurement in edge mode, output timer, abnormal data elimination, SHL change, group judgment, Others simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position), zero-set/offset Display

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

* Measuring unit dual connection, extra-fine line measurement, and some of the communication commands are not available.

Measuring Unit External Dimensions

Unit: mm 15

100

420 190

70 (measuring point) 70 11 3 11 Center of

Measuring range

90

5 50

Cable space

120

25

70min

60

60

200

70 (Center of measuring point) 8 170

15.5

35 56 70

10.5

7

90 50 22

ø3.1 (Measuring position) 8-M3

G-33

74

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Optional Accessories

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-500S • Capable of measuring down to 5μm outside diameter*1. • Provides ultra-high accuracy of ±0.3μm over the entire measuring range (5μm to 2mm).

• Ultra-high speed measurement of 3200 scan/ sec. Suitable for high speed lines or in applications subject to vibration.

• Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual • Standard calibration gage set (ø0.1, ø2.0) : No.02AGD110 • Guide pulley : No.02AGD200 • Air blower : No.02AGD220 Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

G

SPECIFICATIONS

Order No. 544-531 544-532 Applicable laser standards JIS IEC, FDA User's Manual Japanese version English version Measuring range 0.005 to 2mm*1 Resolution 0.01 to 10μm (selectable) ±0.03μm Repeatability*2 ±0.3μm Accuracy (20°C)*3 ±0.4μm Positional error*4 1×2mm (0.005 to 2mm) Measuring range*5 Scanning rate 3200 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 76m/s Temperature 0 to 40°C Operating environment Humidity RH 35 to 85% (no condensation) Protection Level IP64*6 *1: The measuring range for the transparent object will be 0.05mm to 2mm. Please consult your local Mitutoyo office for objects smaller than 0.05mm. The measuring range will be 0.1mm to 2mm in the 1 to 255 edge measurement mode or when activating the automatic workpiece detection. If using the optional dual connection unit for LSM-6200, the measuring range will be 0.05mm to 2mm. *2: Determined by the value of ±2 ( : standard deviation) when measuring ø2mm at the interval of 0.32 sec. (average 1024 times). *3: Center of the measuring range for cylindrical workpieces outside diameter. *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction. Note: When using extra-fine line measurement function (FINE), guide messages for setting the following will not be displayed: dualmeasurement, segment designation, automatic workpiece detection, and group judgment.

DIMENSIONS

Unit: mm ø3.1, depth 6 (Measuring position)

11

11 70min Cable space

103

46 34 Working distance 1

32

Measuring range

126

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

55 181

G-34

84

32.5 25

2

40

15.5

40

10.5 17.5

M3, depth 6 (×4)

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-501S • Provides ultra-high accuracy of ±0.5μm over the entire measuring range (0.05 to 10mm).

Optional Accessories

• Narrow range accuracy of ±(0.3+0.1 D)μm for high precision measurement. • Ultra-high speed measurement of 3200 scan/ sec. Suitable for high speed lines or in applications subject to vibration.

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE." • Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual

G SPECIFICATIONS

Order No. 544-533 544-534 Applicable laser standards JIS IEC, FDA User's Manual Japanese version English version Measuring range 0.05 to 10mm Resolution 0.01 to 10μm (selectable) 1 Repeatability* ±0.04μm Whole range ±0.5μm Accuracy*2 (20°C) Small range ±(0.3+0.1 D)μm*3 4 Positional error* ±0.5μm Measuring range*5 2×10mm (ø0.05 to ø0.1mm) 4×10mm (ø0.1 to ø10mm) Scanning rate 3200 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 113m/s Temperature 0 to 40°C Operating environment Humidity RH 35 to 85% (no condensation) Protection Level IP64*6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø10mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

DIMENSIONS

Unit: mm

• Extension relay cable Order No. 02AGC150A

Cable length 1m

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

40

40

230 123

39

40

157

110 M4, depth 8 (×3)

73 40.5

38.5

Reception Unit 30

ø3.1 hole, To Reception Unit ø3.1 hole, depth 6 depth 6 (Cable length 0.6m) Dimension when disconnected (bottom view)

G-35

Measuring position M4, depth 8 (×3) 9.5

Base

14.5

Emission Unit

9.5

Relay cable

Measuring range

20

10

8

68 Max. 100 34 34*7 8 4

9.5

40

70 min Cable space

150

57.5 84 104

Signal cable

15.5

42 53 64

10.5

18.5

50 22

ø3.1 hole, depth 6 (Measuring position) 6 8-M3

• Standard calibration gage set (ø0.1, ø10.0) : No.02AGD120 • Wire guiding pulley : No.02AGD210 • Adjustable workstage : No.02AGD400 • Air blower : No.02AGD230 • Workstage : No.02AGD270 • Extension signal cable Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m

Emission Unit: 0.7kg Reception Unit: 0.4kg Base: 0.3kg Signal cable (5m): 0.5kg *7: Extendable up to 66mm.

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Optional Accessories

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-503S • Ensures ±1.0μm accuracy over the entire measuring range (0.3 to 30mm). • Narrow range accuracy of ±(0.6+0.1 D)μm for high precision measurement.

• Ultra-high speed measurement of 3200 scan/ sec. Suitable for high speed lines or in applications subject to vibration.

• Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual

Laser safety

Order No. 544-535 544-536 Applicable laser standards JIS IEC, FDA User's Manual Japanese version English version Measuring range 0.3 to 30mm Resolution 0.02 to 100μm (selectable) ±0.11μm Repeatability*1 ±1.0μm Accuracy*2 Whole range (20°C) Small range ±(0.6+0.1 D)μm*3 Positional error*4 ±1.5μm 10×30mm (0.3 to 30mm) Measuring range*5 Scanning rate 3200 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 226m/s Temperature 0 to 40°C Operating environment Humidity RH 35 to 85% (no condensation) Protection Level IP64*6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø30mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

DIMENSIONS

Unit: mm

ø3.1

(Measuring position)

50 22

8-M3

6

202 48

48

355

70 min

130

Cable space

Max. 350 170

50*7 8

80 8

10

55

Relay cable

84.5

46

54.5 105

M4, depth 8, ø3.3 through hole (×3) For mounting side plate (same in the back) 90

Measuring range

57

M4, depth 8, ø3.3 through hole (×2) For mounting side plate (same in the back) 41

9.5

9.5 9.5

14.5

150

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

To Reception Unit (Cable length 1.4m)

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

42

20

Base 65.5 250

95.5

Reception Unit

Measuring range

5.5 80 57.5

Emission Unit

90 110

42

57

259

12 30

Signal cable

15.5

42 53 68

10.5

Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

SPECIFICATIONS

18.5

• Standard calibration gage set (ø0.1, ø30.0) : No.02AGD130 • Adjustable workstage : No.02AGD490 • Air blower : No.02AGD240 • Workstage : No.02AGD270 • Extension signal cable Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m 02AGN780D 20m • Extension relay cable Order No. Cable length 02AGC150A 1m 02AGC150B 3m 02AGC150C 5m

G

ø3.1, depth 6 M4, depth 8 (×3) ø3.1, depth 6 M4, depth 8 (×3) (Reference hole) For mounting base (Reference hole) For mounting base Dimension when disconnected (bottom view)

G-36

Emission Unit: 1.1kg Reception Unit: 0.6kg Base: 0.5kg Signal cable (5m): 0.5kg *7: Extendable up to 270mm

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-506S • Ensures ±3μm accuracy over the entire measuring range (1 to 60mm).

Optional Accessories

• Narrow range accuracy of ±(1.5+0.5 D)μm in for high precision measurement. • Ultra-high speed measurement of 3200 scan/sec. Suitable for high speed lines or in applications subject to vibration.

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE." • Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual

G SPECIFICATIONS

544-537 JIS Japanese version

Order No. Applicable laser standards User's Manual Measuring range Resolution Repeatability*1 Whole range Accuracy*2 (20°C) Small range Positional error*4 Measuring range*5 Scanning rate Laser wavelength Laser scanning speed Temperature Operating environment Humidity Protection Level

1 to 60mm 0.05 to 100μm (selectable) ±0.36μm ±3μm ±(1.5+0.5 D)μm*3 ±4μm 20×60mm (1 to 60mm) 3200 scans/s 650nm (Visible) 452m/s 0 to 40°C RH 35 to 85% (no condensation) IP64*6

• Standard calibration gage set (ø1.0, ø60.0) : No.02AGD140 • Adjustable workstage : No.02AGD520 • Air blower : No.02AGD250 • Extension signal cable Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m 02AGN780D 20m • Extension relay cable Order No. Cable length 02AGC150A 1m 02AGC150B 3m 02AGC150C 5m

544-538 IEC, FDA English version

*1: Determined by the value of ±2 ( : standard deviation) when measuring ø60mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

DIMENSIONS

Unit: mm 100 50 22

7

90

90

Cable space

273

Max. 700

185

163

8 Measuring range

7 97 66

Emission Unit

110*7 20 8

82

Reception Unit 42

60

540

12

70min 42

102

360

110 130

258

Signal cable

15.5

42 58 70

10.5

(Measuring position) 12-M3

Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

18.5

ø3.1

Laser safety

168.5

87 348

Relay cable

115.5 192

20

Base 87

71

M5, depth 10, ø4.2 through hole (×3) M5, depth 10, ø4.2 through hole (×2) For mounting side plate (same in the back) For mounting side plate (same in the back) 121

63

9.5

Measuring range

9.5

14.5

174.5

9.5

162

To Reception Unit ø3.1, depth 6 M5, depth 10 (×3) ø3.1, depth 6 (Cable length 1.4m) (Reference hole) For mounting base (Reference hole)

M5, depth 10 (×3) For mounting base

Dimension when disconnected (bottom view)

G-37

Emission Unit: 1.4kg Reception Unit: 0.8kg Base: 0.8kg Signal cable (5m): 0.5kg *7: Extendable up to 537mm

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Optional Accessories

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE."

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-512S • Ensures ±6μm accuracy over the entire measuring range (1 to 120mm).

• Narrow range accuracy of ±(4.0+0.5 D)μm in for high precision measurement. • Ultra-high speed measurement of 3200 scan/sec. Suitable for high speed lines or in applications subject to vibration.

• Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

SPECIFICATIONS

Order No. 544-539 544-540 Applicable laser standards JIS IEC, FDA User's Manual Japanese version English version Measuring range 1 to 120mm Resolution 0.1 to 100μm (selectable) Repeatability*1 ±0.85μm Whole range ±6μm Accuracy*2 (20°C) Small range ±(4.0+0.5 D)μm*3 4 Positional error* ±8μm Measuring range*5 30×120mm (1 to 120mm) Scanning rate 3200 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 904m/s Temperature 0 to 40°C Operating environment Humidity RH 35 to 85% (no condensation) Protection Level IP64*6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø120mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

DIMENSIONS

ø3.1

Unit: mm

200 100

(Measuring position)

19

48 68 80

8

8-M4

18.5

• Standard calibration gage set (ø20.0, ø120.0) : No.02AGD150 • Air blower : No.02AGD260 • Extension signal cable Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m 02AGN780D 20m • Extension relay cable Order No. Cable length 02AGC150A 1m 02AGC150B 3m 02AGC150C 5m • Roll diameter/form measuring instrument (Refer to page G-60 for details.)

G

7

312 150

88

400

150

Signal cable 70 min

700 107 131*7 30 9

48

Reception Unit

162 192

190 9 Measuring range

Relay cable

96

96

263

30

9

9

84

Emission Unit

120 146

Max. 700

146

48

321

272

Cable space

Base

137

52 238

462

M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back)

M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back) 256

To Reception Unit (Cable length 1.4m)

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

85

8

8

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

144

M6, depth 12 (×3) For mounting base 19

Measuring range 19

192

M6, depth 12 (×3) For mounting base

ø3.1, depth 6 (Reference hole)

ø3.1, depth 6 (Reference hole) Dimension when disconnected (bottom view)

G-38

Emission Unit: 3.0kg Reception Unit: 1.2kg Base: 1.8kg Signal cable (5m): 0.5kg *7: Extendable up to 510mm

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Measuring Unit) LSM-516S • Ensures ±7μm accuracy over the entire measuring range (1 to 160mm). • Narrow range accuracy of ±(4.0+2.0 D)μm for high precision measurement.

Optional Accessories

• Ultra-high speed measurement of 3200 scan/ sec. Suitable for high speed lines or in applications subject to vibration.

• Multifunctional display unit, LSM-6200: Order No. Display type Remarks 544-071 Japanese mm/E Japanese user's manual 544-071* English mm/E English user's manual 544-072* English mm/inch * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE." • Easy-to-operate display unit, LSM-5200: Order No. Remarks 544-046 Japanese user's manual 544-047 English user's manual

G SPECIFICATIONS

Order No. 544-541 544-542 Applicable laser standards JIS IEC, FDA User's Manual Japanese version English version Measuring range 1 to 160mm Resolution 0.1 to 100μm (selectable) ±1.4μm Repeatability*1 ±7μm Accuracy*2 Whole range (20°C) Small range ±(4.0+2.0 D)μm*3 Positional error*4 ±8μm 40×160mm (1 to 160mm) Measuring range*5 Scanning rate 3200 scans/s Laser wavelength 650nm (Visible) Laser scanning speed 1206m/s 0 to 40°C Operating Temperature environment Humidity RH 35 to 85% (no condensation) Protection Level IP64*6 *1: Determined by the value of ±2 ( : standard deviation) when measuring ø160mm at the interval of 0.32 sec. (average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in cylinder position either in the optical axis direction or in the scanning direction. *5: The area given by [optical axis direction]×[scanning direction]. *6: The protection level provided for the interior. If the workpiece or glass of the measuring unit window is soiled by water or dust, the unit may malfunction.

DIMENSIONS

200 100

Unit: mm

• Extension relay cable Order No. 02AGC150A 02AGC150B 02AGC150C

Cable length 1m 3m 5m

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

37

74 100 120

8

20.5

ø3.1 (Measuring position) 8-M4

• Standard calibration gage set (ø20, ø160) : No.02AGM300 • Extension signal cable Order No. Cable length 02AGN780A 5m 02AGN780B 10m 02AGN780C 15m 02AGN780D 20m

9 350

250

170 880

88

224 249

160

208

25

9 218

87.5 M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back) 360 M6, depth 12, ø5 through hole (×3) For mounting side plate (same in the back) 13 136 400Note1

306 520

200 8.7

9

200 8.7 40 Measuring range

100 107

206

41 8

10

41 8

200 10

M6, depth 12 (×3) For mounting base

160

400

320

208

Cable space

110

600

Min. 70

M6, depth 12 (×3) For mounting base

ø3.1 hole, depth 6 (Reference hole) Note1: Distance between emission unit and reception unit: 400mm to 800mm

Measuring position

G-39

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Optional Accessories

• Standard calibration gage set (ø1, ø60) : No.02AGD170

SERIES 544 Laser Scan Micrometer (Display Unit Integrated Model) LSM-9506 • High accuracy of ±2.5μm, integrated display unit with many functions equivalent to the multi-function display unit.

G SPECIFICATIONS

544-115* mm 0.5 to 60mm 0.05 to 100μm (selectable)

544-116** inch/mm .02” - 2.36”/0.5 - 60mm .000002” - .005/0.00005 - 0.1mm ±0.6μm (±.00003") ±2.5μm (±.0001") ±2.5μm (±.0001") L: Displacement between workpiece center and optical axis center ±5x60mm (±.2x2.36") 1600 scans/s 650nm (Visible)*5 226m/s (8900" / s) 16-digit dot matrix (upper column) + 7 segment 11-digit (lower column) ,guidance LEDs RS-232C, Digimatic code output unit (1ch) No AC100V-240V ±10%, 40VA, 50/60Hz 0 to 40°C, RH 35 to 85% (no condensation) *1: Determined by the value of ±2 ( : standard deviation) when measuring ø10mm at the interval of 0.32 sec. Order No. Type Measuring range Resolution Repeatability*1 Accuracy*2 (20°C) Positional error*3 (optical axis/scanning direction) Measuring range*4 Scanning rate Laser wavelength Laser scanning speed Display unit Standard interface Optional interface Power supply Operating environment

Laser safety Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC608251 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

(average 1024 times). *2: Center of the measuring range for cylindrical workpieces outside diameter. *3: D=Difference in diameter between the master gage and workpiece (Unit: mm) *4: An error of the outside diameter due to variation in workpiece position either in the optical axis direction or in the scanning direction. *5: FDA Class II (544-116-1A)/IEC Class 2 (Allmodels except 544-116-1A) semiconductor laser for scanning (Maximum power: 1.0mW) * To denote your AC power cable add the following suffixes to the order No.: D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE. ** To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, K for KC, C and No suffix are required for PSE.

ø3.1 (Measuring position)

10

12-M3

Unit: mm

10

150 100 50 22

15.5

180

100 120

60

10.5

Cable space 80

DIMENSIONS

83 382

97 180

85

647 100 11

100 10 8

82 40 52.5

98

Measuring range

25

8

202

60

365

11

11

52

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-40

172

13.5

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Multifunctional Display Unit) LSM-6200 • Segment measurement (7 points) or edge measurement (1 to 255 edge) can be selected. • A function to eliminate abnormal values is standard. • 100 tolerance values, preset values, or settings can be stored.

• 2-axis display unit enables s2 items be displayed simultaneously. • Capable of statistical analysis such as: average, maximum value, minimum value, range (max. - min.).

G

SPECIFICATIONS

544-071* 544-072* mm inch/mm 16-digit plus 11-digit fluorescent display, and guide message LED 1 to 7 (1 to 3, transparent) or 1 to 255 edges*1 Arithmetic average: per 2 to 2048/ Moving average: per 32 to 2048 (Arithmetic average is per 16 to 2048 Averaging times when using 544-531, 544-532) Selection from "target value + tolerance", "lower tolerance + upper tolerance", or "7 classes multi-limit Judgment tolerance zone". Measurement mode Standby, Single measurement, Continuous measurement Statistical analysis Maximum, Minimum, Average, Dispersion, (S.D) Size 335 (W)×134 (H)×250 (D)mm Power supply 100 - 240 V AC ±10%, 40VA, 50/60Hz Standard I/F RS-232C, Analog I/O Optional I/F Digimatic code output unit (2-ch), 2nd I/O analog I/F, BCD I/F Operating environment 0 to +45°C, RH 35 to 85% (no condensation) Nominal setting, sample setting, selection of unnecessary digits, transparent object measurement*2, measurement of odd fluted parts, automatic measurement in edge mode, output timer, abnormal data Others elimination, SHL change, group judgment, simultaneous measurement, statistical processing, mastering, buzzer function, automatic workpiece detection (dimension/position)*1, zero-set/offset, dual measurement (optional) *1: The measuring range will be 0.1mm to 2mm in the 1 to 255 edge measurement mode or when activating the automatic workpiece detection with 544-531, 544-532. Each function has its combination limit. *2: The measuring range is 50μm to 2mm when using 544-531, 544-532. For smaller range, contact your local Mitutoyo sales office. * To denote your AC power cable add the following suffixes to the order No.: A for UL/CSA, D for CEE, DC for CCC, E for BS, F for SAA, K for KC, C and No suffix are required for PSE. ** Cannot be connected to 544-495, 544-496. ** Previous models such as 544-451 cannot be connected. Order No. Type Display Segment

DIMENSIONS

Unit: mm

335

134

キーロック

LD1 ON

-NG

CAL

GO

オフセット

+NG

統計処理

RUN

同時測定

設定

葦字

7

8

9

C

H.CAL

4

5

6

合否判定

L.CAL

1

2

3

BUSY

0

+/−

単位

統計処理

LD2 ON

基準値 入力

13

Cable space 80

250

281.4

12°

13.5

測定

読込み

125

シフト PROG.

TRANSMITTER-1

REMOT E INTERLOCK

RS-232C

B1

I/ O ANALOG

B6

ID ID RO M 1

FOOT SW.

SCA N SIG.-1

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

A6

121

A1

G-41

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

SERIES 544 Laser Scan Micrometer (Panel-mount Type Display Unit) LSM-5200 • A compact controller which could be used for multi-unit system configurations. • Capable of simple connection to a PC via USB.

• A Panel-mount type display unit designed for the LSM-S series. • Analog I/O and RS-232C is standard. • Measurement of odd fluted parts, and simultaneous measurement / 2-program function are equipped.

G

SPECIFICATIONS

544-047 9 digits plus 8 digits LED, guide message LED 1 to 7 (1 to 3, transparent) or 1 to 255 edges*1 Arithmetic average: from 4 to 2048; Moving average: from 32 to 2048 (Arithmetic average is from 16 to 2048 when using LSM-500S.) Selecting from "target value ± tolerance value" or "lower limit/upper limit". Standby, Single measurement, Continuous measurement Calculation result is output via USB or RS-232C. 144 (W)×72 (H)×197.1 (D)mm 24V DC±10%, 1.3A or more USB2.0, RS-232C, I/O analog

Order No. Display Segment

Averaging method Judgment Measurement mode Statistical analysis External dimensions Power supply*3 Standard I/F Operating environment Preservation environments Others Mass

0 to 40°C, RH 35 to 85% (no condensation) −20 to 70°C, RH 35 to 85% (no condensation) Measurement of odd fluted parts, simultaneous measurement, nominal setting, sample setting, selection of unnecessary digits, transparent object measurement*2 Automatic workpiece detection (dimension/position detected)*1, abnormal data elimination, mastering, statistical processing (when using USB, RS-232C), output timer, automatic measurement in edge mode, presetting Note that every function is limited in its combination possibilities. See the user manual for details. 1.4 kg

*1: The measuring range will be 0.1mm to 2mm in the 1 to 255 edge measurement mode or when activating the automatic workpiece detection with 544-531, 544-532. Each function has its combination limit. *2: The measuring range is 50μm to 2mm when using 544-531, 544-532. For smaller ranges, contact your local Mitutoyo sales office. *3: DC24V external power supply (commercial item) is required separately. Note 1: Cannot be connected to 544-495, 544-496. Note 2: Previous models such as 544-451 cannot be connected. Note 3: For USB communication with a PC, a dedicated device driver is required. For details, contact your local Mitutoyo sales office.

DIMENSIONS

197.1

Front view

Side view

Unit: mm

(20.5)

138 (Aluminum case)

68 (Aluminum case)

*240.3 + (t−0.6)

(4.4)

72

144



0 68 +0.7

Rear view

138+10

140.4

Refer to the Laser Scan Micrometer (Catalog No. E4156) for more details.

Support for mounting plate Bottom view Panel thickness: 1.6mm to 6mm

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Dimensions of panel mounting slot (DIN 43 700-144×76) Panel thickness: 1.6mm to 6mm Mass: 1.4kg

G-42

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Display Unit) Optional Accessories LSMPAK • Software can import measurement data from multiple LSM-5200 display units to a PC allowing a variety of measuring systems to be constructed. • Capable of processing a maximum of 10 channels of measurement data (USB-HUB connection). • Capable of Calculation between channels, statistical analysis, file output of calculation results. • Various display functions such as counter display, graph display, and calculation result are equipped. * Refer to page G-42 for specifications of LSM-5200.

G

Sample Screen

Measurement Examples Printer roll multi-point simultaneous measurement

LSMPAK

544-047

544-531, 532 Commercially available products, such as USB hubs and cables, are available for connecting to the display unit.

SPECIFICATIONS

02NGA003 (Korean) 02NGA004 (German) Display unit: 544-047 (Ver.1.004A or later) Measuring unit: 544-531, 532 series Display function Max. 12 windows (counter, meter, chart, overall judgment) Presetting, data output, sample measurement, resolution select, judgment setting, measurement of Setup function odd number fluted parts, simultaneous measurement *Each function has its combination limit. Measurement function Single, continuous measurement, single automatic repetition Calculation function Arithmetic operation, maximum, minimum, range, average, total (any combination available) GO/NG judgment 3-step (–NG, GO, +NG) Interface USB2.0 (Hi-Speed communication recommended) Maximum connection 10 units OS Windows XP, 7 (32-bit) CPU Pentium 4, 2GHz or better recommended Operating environment Memory 1GB or more (PC) HDD free space 500MB or more Display 124×768 dot, True Color (32-bit) or more recommended Order No.

02NGA002 (English)

Applicable models

G-43

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

An inspection certificate is supplied as standard. Refer to page IX for details.

SERIES 544 Laser Scan Micrometer (Measuring Unit) Optional Accessories Standard calibration gage set • Standard cylinder gage set suitable for calibration of Laser Scan Micrometers. • Nominal gage diameters (1 to 160mm) are as given in Specifications.

G SPECIFICATIONS For calibrating models 544-495, 544-496 544-531, 544-532 544-533, 544-534 544-535, 545-536 544-537, 544-538 544-539, 544-540 544-541, 544-542 544-115, 544-116 Set No. 02AGD180 02AGD110 02AGD120 02AGD130 02AGD140 02AGD150 02AGM300 02AGD170 Stand 02AGD181 02AGD111 02AGD121 02AGD131 02AGD141 02AGD151 02AGM320 02AGD171 Configuration ø1: 02AGD920 ø0.1: 958200 ø0.1: 958200 ø1: 02AGD920 ø1: 02AGD920 ø20: 229730 ø20: 229730 ø1: 02AGD920 Gages (Order No.) ø25: 02AGD963 ø2 : 958202 ø10: 229317 ø30: 02AGD961 ø60: 02AGD962 ø120: 234072 ø160: 02AGM303 ø60: 02AGD962 Carrying case 02AGD190 958203 958203 02AGD980 02AGD980 02AGD990 02AGM310 02AGD970

Workstage • Easy set-up and height adjustment enables high-precision measurement.

SPECIFICATIONS Model Order No.

Installation example (LSM-902)

544-533, 544-534 544-535, 544-536 544-495, 544-496 02AGD270

Adjustable workstage • Vertical/horizontal slide mechanism enables easy • Best suited for quality assurance of high measurement of various workpiece diameters. precision pin gages.

Measurement Examples • Roller of copying machine

• Pin gage or plug gage

Basic configuration Basic set

Order No. Model Standard Accessories Measuring range (mm) 02AGD280 544-495, 544-496 0.1 - 25 V-block (02AGD420), 2 pcs 02AGD400 544-533, 544-534 0.05 - 10 Stopper (02AGD430), 1 pc (1) Main unit 02AGD490 544-535, 544-536 0.3 - 30 (2) V-block 02AGD520 544-537, 544-538 1 - 60 V-block A (02AGD550), 2 pcs (3) Stop V-block B (02AGD550), 1 pc 02AGD370 0.5 - 60 544-115, 544-116 V-block C (02AGD570), 1 pc 02AGD680 0.5 - 60 * The stop is not included in the basic set for 544-537, 544-538, 544-115, 544-116. • Optional part for the adjustable workstage, such as center support, adjustable V-block (up/down) etc., are available.

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-44

Horizontal stroke (mm) 130 130 200 300 200 300

Vertical stroke (mm) 47 32 35 45 45 45

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Measuring Unit) Optional Accessories Guide pulley • Used for supporting measurement of outside diameter of fine wirelike materials such as magnetic wire or fiber.

SPECIFICATIONS

G

Model 544-531, 544-532 Order No. 02AGD200 Each measurement range is as follows: 544-531, 544-532: ø5μm to ø1.6mm 544-533, 544-534: ø50μm to ø2mm

544-533, 544-534 02AGD210

For calibration, the calibration gage set for 544-531, 544-532 (No.02AGD110) is required.

Air shield driven by air supply unit • Air blows from the air outlet installed on the laser section to clear dust adhering to the laser window.

SPECIFICATIONS Air supply unit

No.957608

Air shield No.02AGD220 No.02AGD230 No.02AGD240 No.02AGD250 No.02AGD260

Applicable models 544-531, 544-532 544-533, 544-534 544-535, 544-536 544-537, 544-538 544-539, 544-540

The number of air shields that can be driven per air supply unit (No.957608) is as follows: Air shield Quantity No.02AGD220/No.02AGD230 6 No.02AGD240 3 No.02AGD250/No.02AGD260 1 *1: Air shield and air supply unit are sold separately. An air supply unit includes a flow regulating valve and filter. Note, however, that clean air should be supplied. *2: Air shield is supplied with 5m air tube (Outside Diameter: 6mm). *3: Air supply unit is compatible with air tube of 9mm internal diameter.

Extension signal cable / Extension relay cable • Extension signal cables are necessary when the measuring unit and display unit are separated in operation; Extension relay cables are necessary when the optical section is separated in operation. Signal cable (5m) No.02AGN770A Display unit Extension signal cable

Emission Unit

Extension relay cable

Reception Unit

Relay cable, 1.4m (0.6m for 544-533, 544-534) Not equipped with 544-531, 544-532 and 544-495, 544-496

(

SPECIFICATIONS

Extension signal cable

)

Extension relay cable

Order No. Cable length Order No. Cable length 02AGN780A 5m 02AGC150A 1m 02AGN780B 10m 02AGC150B 3m 02AGC150C 5m 02AGN780C 15m 02AGN780D 20m * For 544-531, 544-532 and 544-533, 544-534 the allowable maximum length for signal cable is 20m; relay cable is 2m. * For 544-535, 544-536, 544-537, 544-538, 544-539, 544-540 and 544-541, 544-542 the allowable maximum length for signal cable is 30m; relay cable is 5m. * The maximum extension length of the signal cable and relay cable is 32m in total. * Cannot be used with 544-495, 544-496.

G-45

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

SERIES 544 Laser Scan Micrometer (Display Unit) Optional Accessories Thermal printer DPU-414 • Measurement data can be printed.

SPECIFICATIONS Order No. Printing method Printing capacity Character configuration Printing direction Interface Power supply

02AGD600A 02AGD600B 02AGD600C 02AGD600D Thermal dot matrix 40 Columns (Normal) 9×8 dot matrix

Bidirectional RS-232C AC 100-240V 50/60Hz (AC adapter) 2m (02AGD620A), Printer Standard Accessories Printer cable paper 1 roll, AC adapter Printer paper (optional) Order No.223663 (10-roll set)

Foot switch • 937179T • For LSM Order 544-071, 544-072, 544-495, 544-496, 544-115, 544-116

Interface for LSM6200, 6900 Optional Accessories BCD Interface • Outputs measurement data in BCD output (7-digit) or HEX output. • Data logic can be switched. • Isolated I/O circuitry • Available for 544-071, 544-072, 544-495, 544-496.

SPECIFICATIONS Order No. 02AGC910 Standard Accessories Connector (DDK) 57-30360 (No.214188)

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-46

G

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

SERIES 544 Laser Scan Micrometer (Display Unit) Optional Accessories Digimatic code output unit

• 2-channel Digimatic code output • In simultaneous measurement, measurement data are output as follows: Program No.0 to No.4 in OUTPUT-1 Program No.5 - No.9 in OUTPUT-2 (10 programs operated) • 10 pin MIL type connector. • Output cable is not supplied. Connecting cable (optional) 1m (No.936937) • Available for 544-071, 544-072, 544-495, 544-496.

G SPECIFICATIONS 02AGC840

Order No.

* Output is 6 digits of measurement data. * Displaying 6th and 7th digit after the decimal point is not supported.

Dual connection unit

• Enables second unit connection to the 544-071, 544-072. (both units must be the same model) * Cannot be used for 544-495, 544-496. • Depending on the layout of the two measuring units, large-diameter measurement, XY measurement, and parallel measurement are possible. • Both of the measuring units and display units can be simultaneously operated.

X

Y

(X–Y): flatness (X+Y)/2: average * XY requires 10mm-interval.

SPECIFICATIONS 02AGP150

Order No.

XY Measurement

2nd I/O analog I/F

Parallel Measurement

• I/O, analog output. • Simultaneous measurement is supported by two pairs of GO/NG judgment outputs. • Available for 544-071, 544-072, 544-495, 544496.

SPECIFICATIONS Order No. 02AGP150 Standard Accessories Connector (DDK) 57-30360 (No.214188)

Cable for BCD and 2nd I/O simultaneous mount • Both BCD (No.02AGC910) and 2nd I/O analog I/F (No.02AGC880) can be mounted on 544-071, 544-072, 544-495, 544-496 using this cable. * If using this cable, the dual connection unit (No.02AGP150) cannot be used.

SPECIFICATIONS 02AGE060

Order No.

DIMENSIONS

Unit: mm

200±10

47.8

120±10

G-47

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Quick Guide to Precision Measuring Instruments

Laser Scan Micrometers

■ Compatibility

■ Re assembly after removal from the base

Your Laser Scan Micrometer has been adjusted together with the ID Unit, which is supplied with the measuring unit. The ID Unit, which has the same code number and the same serial number as the measuring unit, must be installed in the display unit. This means that if the ID Unit is replaced the measuring unit can be connected to another corresponding display unit.

■ The workpiece and measuring conditions Depending on whether the laser is visible or invisible, the workpiece shape, and the surface roughness, measurement errors may result. If this is the case, perform calibration with a master workpiece which has dimensions, shape, and surface roughness similar to the actual workpiece to be measured. If measurement values show a large degree of dispersion due to the measuring conditions, increase the number of scans for averaging to improve the measurement accuracy.

■ Electrical interference To avoid operational errors, do not route the signal cable and relay cable of the Laser Scan Micrometer alongside a high voltage line or other cables capable of inducing noise current in nearby conductors. Ground all appropriate units and cable shields.

Observe the following limits when re assembling the emission unit and reception unit to minimize measurement errors due to misalignment of the laser's optical axis with the reception unit.

■ Alignment within the horizontal plane a. Parallel deviation between reference lines C and D: X (in the transverse direction) Reference line D Reference line C

X

b. Angle between reference lines C and D: θx (angle) Reference line D Reference line C

■ Connection to a computer If the Laser Scan Micrometer is to be connected to an external personal computer via the RS-232C interface, ensure that the cable connections conform to the specification.

■ Laser safety

G

x

■ Alignment within the vertical plane c. Parallel deviation between reference planes A and B: Y (in height) Reference plane B

Mitutoyo Laser Scan Micrometers use a low-power visible laser for measurement. The laser is a CLASS 2 EN/IEC60825-1 (2007) device. Warning and explanation labels, as shown right, are attached to the Laser Scan Micrometers as is appropriate.

Reference plane A

Y

d. Angle between reference planes A and B: θy (angle) Reference plane B Reference plane A

y

l Allowable limits of optical axis misalignment Model 544-533, 544-534 544-535, 544-536 544-537, 544-538 544-539, 544-540 544-541, 544-542

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

Distance between Emission Unit and Reception Unit 68mm ( 2.68") or less 100mm ( 3.94") or less 130mm ( 5.12") or less 350mm (13.78") or less 273mm (10.75") or less 700mm (27.56") or less 321mm (12.64") or less 700mm (27.56") or less 800mm (31.50") or less

G-48 G-48

X and Y

θx and θy

within 0.5mm (.02") within 0.5mm (.02") within 1mm (.04") within 1mm (.04") within 1mm (.04") within 1mm (.04") within 1mm (.04") within 1mm (.04") within 1mm (.04")

within 0.4˚ (7mrad) within 0.3˚ (5.2mrad) within 0.4˚ (7mrad) within 0.16˚ (2.8mrad) within 0.2˚ (3.5mrad) within 0.08˚ (1.4mrad) within 0.18˚ (3.6mrad) within 0.08˚ (1.4mrad) within 0.05˚ (1.6mrad)

Laser Scan Micrometer Non-contact, high-speed, high-precision measurement

■ Measurement Examples In-line measurement of glass fiber or fine wire diameter

Measurement of outer diameter of cylinder

Measurement of outer diameter and roundness of cylinder

Diameter

Dia.

Reference edge Out of roundness

G

Measurement of spacing of IC chip leads X- and Y-axis measurement of electric cables and fibers

Measurement of thickness of film and sheet

Reference edge

Measurement of film sheet thickness

Measurement of gap between rollers

Measurement of laser disk and magnetic disk head movement Gap

Reference edge

Measurement of form

Reference edge

Measurement of tape width

Measurement of outer diameter of optical connector and ferrule Dual system for measuring a large outside diameter

G-49

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G

Mitutoyo operates a policy of continuous improvement that aims to provide the customer with the benefit of the latest technological advances. Therefore the company reserves the right to change any or all aspects of any product specification without notice.

G-50 G-50