Geothermal Heat Pump Product Catalog Table of Contents Two-Stage Water-To-Air Units......................................................................................................................................2 Downflow Kits for RXT Units.......................................................................................................................................3 Two-Stage Units Water-To-Water..................................................................................................................................4 Hydronic Air Handler....................................................................................................................................................6 Hydronic A-Coils............................................................................................................................................................6 Thermostats.....................................................................................................................................................................7 Field-Installed Internal Electric Heaters (RXT Series)..............................................................................................7 Field-Installed Internal Electric Heaters (Hydronic Air Handler)............................................................................8 Air Pads............................................................................................................................................................................8 Flow Centers....................................................................................................................................................................9 Replacement Pumps......................................................................................................................................................11 Hose Kits.........................................................................................................................................................................11 Close Loop Adapter Fittings........................................................................................................................................12 Open Loop (Well Water) Accessories.........................................................................................................................13 Replacement Optional Filers.......................................................................................................................................14 Filter Rack......................................................................................................................................................................14 Miscellaneous Installation Accessories......................................................................................................................15 Software..........................................................................................................................................................................15
Geothermal Heat Pump Product Catalog
1
November 2011
Packaged Two-Stage Units Water-to-Air Heat Pumps Roth two-stage water-to-air heatpump: 2 to 6 ton capacity. •Unique Multi-position cabinet that allows field configuration of: •Left or Right Return Air Plenum •Upflow or Downflow Supply Air •Non-Ozone depleting R-410A Refrigerant. •Removable access panels for easy unit service. •Coated air coil for extended lifespan. •ECM blower motor. •Easily accessible top mounted controls. •Corrosion resistant stainless steel drain pan. •ETL certified to UL & CSA standards, AHRI certified to ISO standards. •Copper coaxial heat exchanger, flow switch protected. •Auto retry on system fault to eliminate nuisance service calls. •High efficiency two-stage Copeland Ultratech scroll compressors. •10/5/5 Standard unit warranty: •10 years– Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance WATER-TO-AIR HEAT PUMPS WITH COPPER COIL AND DESUPERHEATER Part #
Description
2380002000
Water-to-air, packaged with ECM, with copper coil and desuperheater Water-to-air, packaged with ECM, with copper coil and desuperheater Water-to-air, packaged with ECM, with copper coil and desuperheater Water-to-air, packaged with ECM, with copper coil and desuperheater Water-to-air, packaged with ECM, with copper coil and desuperheater
2380002001 2380002002 2380002003 2380002004
Tons/ Compatibility 2
Nomenclature RXT024C11MM1CSS
Weight lbs (kg) w/ pkg. 440 (200)
3
RXT036C11MM1CSS
440 (200)
4
RXT048C11MM1CSS
530 (240)
5
RXT060B11MM1CSS
530 (240)
6
RXT072B11MM1CSS
530 (240)
WATER-TO-AIR HEAT PUMPS WITH COPPER COIL AND WITHOUT DESUPERHEATER Part #
Description
2380002005
Water-to-air, packaged with ECM, with copper coil, without desuperheater Water-to-air, packaged with ECM, with copper coil, without desuperheater Water-to-air, packaged with ECM, with copper coil, without desuperheater Water-to-air, packaged with ECM, with copper coil, without desuperheater Water-to-air, packaged with ECM, with copper coil, without desuperheater
2380002006 2380002007 2380002008 2380002009
Geothermal Heat Pump Product Catalog
Tons/ Compatibility 2
Nomenclature RXT024C10MM1CSS
Weight lbs (kg) w/ pkg. 440 (200)
3
RXT036C10MM1CSS
440 (200)
4
RXT048C10MM1CSS
530 (240)
5
RXT060B10MM1CSS
530 (240)
6
RXT072B10MM1CSS
530 (240)
2
November 2011
WATER-TO-AIR HEAT PUMPS WITH CUPRO NICKEL COIL AND DESUPERHEATER Part #
Description
2380002010
Water-to-air, packaged with ECM, with cupro nickel coil and desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and desuperheater
2380002011 2380002012 2380002013 2380002014
Tons/ Compatibility 2
Nomenclature RXT024C11MM1NSS
Weight lbs (kg) w/ pkg. 440 (200)
3
RXT036C11MM1NSS
440 (200)
4
RXT048C11MM1NSS
530 (240)
5
RXT060B11MM1NSS
530 (240)
6
RXT072B11MM1NSS
530 (240)
WATER-TO-AIR HEAT PUMPS WITH CUPRO NICKEL COIL AND WITHOUT DESUPERHEATER Part #
Description
2380002015
Water-to-air, packaged with ECM, with cupro nickel coil and without desuperheater
2380002016 2380002017 2380002018 2380002019
Tons/ Compatibility 2
Nomenclature RXT024C10MM1NSS
Weight lbs (kg) w/ pkg. 440 (200)
Water-to-air, packaged with ECM, with cupro nickel coil and without desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and without desuperheater
3
RXT036C10MM1NSS
440 (200)
4
RXT048C10MM1NSS
530 (240)
Water-to-air, packaged with ECM, with cupro nickel coil and without desuperheater Water-to-air, packaged with ECM, with cupro nickel coil and without desuperheater
5
RXT060B10MM1NSS
530 (240)
6
RXT072B10MM1NSS
530 (240)
DOWNFLOW KITS FOR RXT UNITS
Telescoping duct section with insulation and installation instructions to facilitate the field re-configuration of the Roth RXT heat pump for downflow supply air orientation.
Part #
Description
Nomenclature
Weight lbs (kg) w/ pkg.
Downflow kit for 2-3 ton RXT units
Tons/ Compatibility N/A
2380009000
AXDNFL01A
Downflow kit for 4-6 ton RXT units
N/A
AXDNFL02A
14 (6.5) 14 (6.5)
2380009001
Geothermal Heat Pump Product Catalog
3
November 2011
Two-Stage Units Water-to-Water Heat Pumps Roth two-stage water-to-water heat pump: 3 to 12 ton capacity. •Powder coated bolted steel cabinet. •Non-Ozone depleting R-410A Refrigerant. •Removable access panels for easy unit service. •ETL certified to UL & CSA standards. •AHRI certified to ISO standards (except 12 Ton size). •Copper coaxial heat exchangers, flow switch protected. •Auto retry on system fault to eliminate nuisance service calls. •High efficiency two-stage Copeland Ultratech scroll compressors. •10/5/5 Standard unit warranty: •10 years– Compressor and refrigeration circuit components •5 years- Unit warranty •5 years- Warranty service allowance
WATER-TO-WATER HEAT PUMPS WITH COPPER COIL AND DESUPERHEATER Part #
Description
Tons/
Nomenclature
2380001001 2380001002 2380001003 2380001005 2380001006 2380001007
Water-to-water, with copper coil and desuperheater Water-to-water, with copper coil and desuperheater Water-to-water, with copper coil and desuperheater Water-to-water, with copper coil and desuperheater Water-to-water, with copper coil and desuperheater Water-to-water, with copper coil and desuperheater
3 4 5 8 10 12
RWT036B11AAACSS RWT048B11AAACSS RWT060B11AAACSS RWT092A11AAACSS RWT120A11AAACSS RWT144A11AAACSS
Weight lbs (kg) w/ pkg. 300 (131) 320 (145) 370 (168) 570 (259) 690 (313) 690 (313)
WATER-TO-WATER HEAT PUMPS WITH COPPER COIL AND WITHOUT DESUPERHEATER Part #
Description
2380001009 Water-to-water, with copper coil, without desuperheater 2380001010 Water-to-water, with copper coil, without desuperheater 2380001011 Water-to-water, with copper coil, without desuperheater 2380001013 Water-to-water, with copper coil, without desuperheater 2380001014 Water-to-water, with copper coil, without desuperheater 2380001015 Water-to-water, with copper coil, without desuperheater
Geothermal Heat Pump Product Catalog
Tons/ Nomenclature Weight lbs Compatibility (kg) w/ pkg. 3 RWT036B10AAACSS 300 (131) 4
RWT048B10AAACSS 320 (145)
5
RWT060B10AAACSS 370 (168)
8
RWT092A10AAACSS 570 (259)
10
RWT120A10AAACSS 690 (313)
12
RWT144A10AAACSS 690 (313)
4
November 2011
WATER-TO-WATER HEAT PUMPS WITH CUPRO NICKEL COIL AND DESUPERHEATER Part #
Description
2380001017 Water-to-water, with cupro nickel coil and desuperheater 2380001018 Water-to-water, with cupro nickel coil and desuperheater 2380001019 Water-to-water, with cupro nickel coil and desuperheater 2380001021 Water-to-water, with cupro nickel coil and desuperheater 2380001022 Water-to-water, with cupro nickel coil and desuperheater 2380001023 Water-to-water, with cupro nickel coil and desuperheater
Tons/ Compatibility
Nomenclature
3
RWT036B11AAANSS
Weight lbs (kg) w/ pkg. 300 (131)
4
RWT048B11AAANSS
320 (145)
5
RWT060B11AAANSS
370 (168)
8
RWT092A11AAANSS 570 (259)
10
RWT120A11AAANSS 690 (313)
12
RWT144A11AAANSS 690 (313)
WATER-TO-WATER HEAT PUMPS WITH CUPRO NICKEL COIL AND WITHOUT DESUPERHEATER Part #
Description
Tons/ Compatibility
Nomenclature
2380001025
Water-to-water, with cupro nickel coil, without desuperheater
3
RWT036B10AAANSS
Weight lbs (kg) w/ pkg. 300 (131)
2380001026
Water-to-water, with cupro nickel coil, without desuperheater
4
RWT048B10AAANSS
320 (145)
2380001027
Water-to-water, with cupro nickel coil, without desuperheater Water-to-water, with cupro nickel coil, without desuperheater Water-to-water, with cupro nickel coil, without desuperheater Water-to-water, with cupro nickel coil, without desuperheater
5
RWT060B10AAANSS
370 (168)
8
RWT092A10AAANSS 570 (259)
10
RWT120A10AAANSS 690 (313)
12
RWT144A10AAANSS 690 (313)
2380001029 2380001030 2380001031
Geothermal Heat Pump Product Catalog
5
November 2011
Two Stage Units Water-to-Water Heat Pumps HYDRONIC A-COILS
•For installation on new or existing indoor furnaces for “dual fuel” system configuration •Integral drain pan with primary and secondary drain connections on LH or RH side of pan •Four capacities available 2-5 tons •Coils are ETL and CSA approved Part #
Description
Nomenclature
Uncased Hydronic A-Coil
Tons/ Compatibility 2
ACH024ASR
Weight lbs (kg) w/ pkg. 38 (17.3)
2380009097 2380009098
Uncased Hydronic A-Coil
3
ACH036ASR
46 (20.9)
2380009099
Uncased Hydronic A-Coil
4
ACH048ASR
48 (21.8)
2380009100
Uncased Hydronic A-Coil
5
ACH060ASR
67 (30.5)
HYDRONIC AIR HANDLER
•Multi-position air flow pattern, upflow/downflow, horizontal right/left. Field convertible to downflow and horizontal right configuration (downflow kit required for downflow operation). •Single high efficiency copper tube/aluminum “A” coil for heating and cooling, designed for 100 to 120 degree F water temperature in heating mode. •Variable speed G.E. ECM fan motor with multiple speed taps. •Optimized for use with Roth water-to-water heat pumps. •Corrosion-proof plastic drain pan with primary and secondary drain connections.
Part #
Description
Nomenclature
Hydronic air handler, multi-position, 115V, 1ph
Tons/ Compatibility 2
2380009002 2380009003
Hydronic air handler, multi-position, 115V, 1ph
3
MPH036A9MM1SR 153 (69.4)
2380009004
Hydronic air handler, multi-position, 115V, 1ph
4
MPH048A9MM1SR 220 (99.8)
2380009005
Hydronic air handler, multi-position, 115V, 1ph
5
MPH060A9MM1SR 220 (99.8)
2380009006
Hydronic air handler, multi-position, 208-230V, 1ph 2
MPH024A1MM1SR 131 (59.4)
2380009007
Hydronic air handler, multi-position, 208-230V, 1ph 3
MPH036A1MM1SR 153 (69.4)
2380009008
Hydronic air handler, multi-position, 208-230V, 1ph 4
MPH048A1MM1SR 220 (99.8)
2380009009
Hydronic air handler, multi-position, 208-230V, 1ph 5
MPH060A1MM1SR 220 (99.8)
Geothermal Heat Pump Product Catalog
Weight lbs (kg) w/ pkg. MPH024A9MM1SR 131 (59.4)
6
November 2011
Accessories THERMOSTATS •Programmable •Touchscreen interface •3 heating stages, 2 cooling stages, auto mode changeover •5/1/1 day or 7 day programs •Cool Savings™ feature auto-adjusts set value in cool mode. •Non Programmable •3 heating stages, 2 cooling stages •Auto mode changeover •Cool Savings ™ feature auto-adjusts set value in cool mode Part #
Description
Nomenclature
Weight lbs (kg) w/ pkg.
1F83-0471
1 (.5)
1F95-1291
1 (.5)
2380009012
Digital, non-programmable thermostat (3 heat/2 cool) Digital, programmable thermostat with touchscreen (3 heat/2 cool) Indoor remote sensor
Tons/ Compatibility All water-toair units All water-toair units ATRPE32A
2380009010
ATEISA
2380009013
Outdoor remote sensor
ATRPE32A
ATSPIOA
1 (.5) 1 (.5)
2380009011
FIELD-INSTALLED INTERNAL ELECTRIC HEATERS (RXT SERIES) •Modular electric grid heater provides auxiliary heating to supplement Heat Pump output in heating mode. •Unit installs in the RXT fan plenum, integral time delay relay included.
Part #
Description
2380009014
10kW internal plenum heater
2380009015
15kW internal plenum heater
2380009016
20kW internal plenum heater
Geothermal Heat Pump Product Catalog
Tons/ Compatibility 2-6 ton vertical water-to-air units 4-6 ton vertical water-to-air units 4-6 ton vertical water-to-air units
Nomenclature AHTR101B
Weight lbs (kg) w/ pkg. 9.5 (4.3)
AHTR151B
11.5 (5.2)
AHTR201B
12 (5.4)
7
November 2011
Accessories FIELD-INSTALLED INTERNAL ELECTRIC HEATERS (HYDRONIC AIR HANDLER) •Modular electric grid heater provides auxiliary heating to supplement fancoil output in heating mode. •Compatible with 230V Fan Coil units only.
Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009017
10kW Internal Electric Heater
AHM101S
7 (3.2)
2380009018
10kW Internal Electric Heater
AHM101M
7 (3.2)
2380009019
10kW Internal Electric Heater
AHM101L
7 (3.2)
2380009020
15kW Internal Electric Heater
AHM151L
8 (3.6)
2380009021
20kW Internal Electric Heater
MPH024 -230V only MPH036 -230V only MPH048-060 -230V only MPH048-060 -230V only MPH048-060 -230V only
AHM201L
9 (4.1)
AIR PADS •Available in molded high density plastic, polyethylene foam, or modular blocks. •Provides even support for the Heat Pump unit and vibration isolation. •RXT down flow configuration requires cutable air pad.
Part #
Description
2380009022
33" x 33" x 2" high density plastic pad Vertical pkg'd 2-6 tons 24” x 32” x 2” polyethylene foam pad (Cutable) 30” x 36” x 2” polyethylene foam pad (Cutable) 34” x 50” x 3” polyethylene foam pad (Cutable) 30” x 36” x 3” modular block pad Modular
2380009023 2380009024 2380009025 2380009026
Geothermal Heat Pump Product Catalog
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
AP3333P
15 (6.8)
AP2432F AP3036F AP3450F AP3036P3
3 (1.36) 3 (1.36) 6 (2.7) 15 (6.8)
8
November 2011
Accessories FLOW CENTERS - PRESSURIZED • Self-contained ground loop flow station •Includes insulated housing, Grundfos pump(s), fill and purge connections for the ground loop. •Also included are 1-1/4” Fusion x 1” double o-ring fittings (AGA6PES) for flow center connection to the HDPE ground loop. •Hose kits are required to connect flow center to the heat pump and are found and described in the Hose Kit section of this catalog. Part #
Description
2380009101
Pressure Battery Expansion Tank
2380009102 2380009027 2380009028 2380009029 2380009030 2380009103 2380009104 2380009031 2380009032 2380009033
Tons/ Compatibility
AGFC Flow Centers Geo-Prime Flow Center Reservoir AGFC Flow Tank Centers Single Pump - Brass Valve Check pressure UP26-116U-230V - Double O-Ring drop(normally Fittings 1.5 to 4 tons) Double Pump - Brass Valve Check pressure UP26-116U-230V - Double O-Ring drop(normally Fittings 5 to 7 tons) Single Pump - Brass Valve Check pressure UP26-99F-230V - 1” FPT drop(normally 1.5 to 4 tons) Double Pump - Brass Valve Check pressure UP26-99F-230V - 1” FPT drop(normally 3.5 to 6 tons) Single Pump - Brass Valve Check pressure UP26-99-230V - Double O-Ring drop(normally Fittings 1.5 to 4 tons) Double Pump - Brass Valve Check pressure UP26-99-230V - Double O-Ring drop(normally Fittings 5 to 7 tons) Three Pump - Brass Valve Check pressure UP26-99F-230V - 1” FPT drop(normally 6 to 9 tons) Four Pump - Brass Valve Check pressure UP26-99F-230V - 1”FPT drop(usually 7 to 10 tons) Loop Pump Sharing Module (for using All one flow center for 2 units)
Geothermal Heat Pump Product Catalog
Nomenclature
Weight lbs (kg) w/ pkg.
APBTA
5 (2.3)
AGPTA
13 (5.9)
AGFC1A
32 (14.5)
AGFC2A
37 (16.8)
AGFC1B
37 (16.8)
AGFC2B
42 (19.1)
AGFC1D
24 (10.9)
AGFC2D
30 (13.6)
AGFC3E
55 (24.9)
AGFC4E
60 (27.2)
APSMA
1 (.5)
9
November 2011
Accessories FLOW CENTERS - NON-PRESSURIZED •B&D QT model insulated flow station •Single and multiple pump configurations available •Air separation chamber- continuous purge function •Removable lid •Easy to monitor fluid volume and flow rate •No purge cart required if valved indoor headers are used.
Part #
Description
2380009102
Geo-Prime Reservoir Tank "AGFC Double (creates non-pressurized system with O-ring pressurized flow centers) Pressurized Flow Centers" Single Pump QT Series Module Check pressure -UP26-99F-230V - 1” FPT drop(normally 1.5 to 3 tons) Single Pump QT Series Module Check pressure -UP26-116F-230V - 1” FPT drop(normally 1.5 to 3 tons) Double Pump QT Series Module Check pressure -UP26-99F-230V - 1” FPT drop(normally 3.5 to 6 tons) Double Pump QT Series Module Check pressure -UP26-116F-230V - 1” FPT drop(normally 3.5 to 6 tons) Four Pump QT Series Module Check pressure -UP26-99F-230V - 1” FPT drop(usually 7 to 10 tons)
2380009106 2380009107 2380009108 2380009109 2380009110
Geothermal Heat Pump Product Catalog
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
AGPTA
13 (5.9)
ABFC1A
41 (18.6)
ABFC1B
41 (18.6)
ABFC2A
50 (22.7)
ABFC2B
50 (22.7)
ABFC4A
150 (68.2)
10
November 2011
Accessories REPLACEMENT PUMPS • Replacement Grundfos pumps for pressurized and non-pressurized flow centers, 230V.
Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009034
UP26-116F-230V Replacement Pump
AGPA1
11 (5)
2380009035
UP26-99F-230V Replacement Pump
AGPA2
11 (5)
2380009111
UP26-99F-230V Replacement Pump
ABPA1
11 (5)
2380009112
UP26-116F-230V Replacement Pump
Pressurized flow center Pressurized flow center Non-pressurized flow center Non-pressurized flow center
ABPA2
11 (5)
HOSE KITS • Complete 10’ hose kit required for connecting the Heat Pump to the pressurized flow station connections. •Includes hose clamps, pressure and temperature test fittings, male NPT fittings for the source connections on the unit and fittings for the flow station connections as specified in the product descriptions below. Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009036
Hose Kit: 10’ 1” rubber hose, hose clamps, (2)1/4” P/T fittings, (2) 1" MPT x 1" insert w/P/Tports, (2) double o-ring x 1” hose barb fittings Hose Kit: 10’ 1” rubber hose, hose clamps, (2)1/4” P/T fittings, (2) 1” MPT x 1” insert w/P/T ports, (2)AGBA55 1” MPT x 1” barb fittings
All units with AGFC_A series flow centers
AGHK5A
9.5 (4.3)
All units withAGFC_B and ABFC_A series flow centers Hose Kit Adapter - 3/4" FPT x 1" female 2 ton water-toswivel water units Hose Kit Adapter - 1" FPT x 1" female All except 2 ton swivel water-to-water
AGHK5B
9.5 (4.3)
SNC45
.5 (.17)
SNC55
.5 (.17)
2380009037
2380009038 2380009116
Geothermal Heat Pump Product Catalog
11 November 2011
Accessories CLOSED LOOP ADAPTER FITTINGS
Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009039 2380009040
AGFC_A series AGFC_A series
AGA5INS AGA6INS
1.55 (.7) 1.55 (.7)
AGFC_A series AGFC_A series AGFC_A series
AGA5MPT AGA5PES AGA6PES
1.55 (.7) .55 (.25) .55 (.25)
AGFC_A series
AGPVC6
1 (.5)
AGFC_A series
AGAFP
.7 (.3)
AGFC_A series AGFC_A series
AGA5FPT AGAMGH
1.55 (.7) .5 (.2)
AGFC_A series
AGAFGH
.5 (.2)
2380009048
Double O-Ring x 1” Brass Insert (Set of 2) Double O-Ring x 1.25” Brass Insert (Set of 2) Double O-Ring x 1” Brass MPT (Set of 2) Double O-Ring x 1” PE Socket (Set of 2) Double O-Ring x 1.25” PE Socket (Set of 2) Double O-ring x 1.25" PVC Glue (Set of 2) Double O-Ring x Cam Lever Male Elbow (Set of 2) Double O-Ring x 1” (FPT) (Set of 2) Double O-Ring x Garden Hose Male Fitting to use when replacing a pump to avoid using a flush cart (Set of 2) Double O-Ring x Garden Hose Female Fitting to use when replacing a pump to avoid using aflush cart (Set of 2) 1” MPT x 1” Barbed Brass Adaptor
AGBA55
.6 (.3)
2380009049
1” MPT x 1.25” Barbed Brass Adaptor
AGBA56
1 (.5)
2380009050
1.25” PE Fusion x 1” Brass MPT
GFMA65
.6 (.3)
2380009052
AGO5INS
1.7 (.8)
AGFC_A series
AGO5MPT
1.55 (.7)
2380009054 2380009055
Double O-Ring x 1” Hose Barb El w/PT Tap (Set of 2) Double O-Ring x 1” MPT Elbow w/PT Tap (Set of 2) 1” Check Valve (Threaded) 3-Way Valve Kit
ABFC_A & AGFC_B series ABFC_A & AGFC_B series ABFC_A & AGFC_B series AGFC_A series
2380009056
1.25” PE Double Flush Valve
2380009041 2380009042 2380009043 2380009113 2380009044 2380009045 2380009046 2380009047
2380009053
Geothermal Heat Pump Product Catalog
Parallel pumping ASCV5A Non-press with AGFVK inside header Non-press with APDFV inside header
12
1 (.5) 2 (.9) 69.5 (31.5)
November 2011
Accessories OPEN LOOP (WELL WATER) ACCESSORIES
Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009057 2380009058 2380009059 2380009060
1” Plastic Solenoid Valve, 24V, Threaded 1" Brass Solenoid Valve, 24V, Threaded Solenoid Valve Replacement Coil, 24V Taco Zone Valve 0.75” FPT - 24VAC coil with 22VA draw Taco Zone Valve 1” SWT - 24VAC coil with 22VA draw Taco Zone Valve Power Head Replacement Honeywell Solenoid Valve Actuator
Up to 6 tons Up to 6 tons APV5 & ABV5 Up to 5 GPM
APV5A ABV5A ABVCA AMV4
1 (.5) 3 (1.4) 1 (.5) 2 (.9)
Up to 10 GPM
AMV5
2 (.9)
AMV-PH AVAHA
1 (.5) 2 (.9)
AVB4HA AVB5HA AFR2
2 (.9) 2 (.9) 1 (.5)
AFR3
1 (.5)
AFR4
1 (.5)
AFR5
1 (.5)
AFR6
1 (.5)
AFR7
1 (.5)
AFR8
1 (.5)
AFR9
1 (.5)
AFR10
1 (.5)
AGPT2A AGPT3A AFM10A
2 (.9) 2 (.9) 1 (.5)
AFM12A
1 (.5)
2380009061 2380009062 2380009063 2380009064 2380009065 2380009066 2380009067 2380009068 2380009069 2380009070 2380009071 2380009072 2380009073 2380009074 2380009075 2380009076 2380009077 2380009078
AVM valves AVB4HA & AVB5HA Honeywell Solenoid Valve Brass Body - .75” AVAHA Honeywell Solenoid Valve Brass Body - 1” AVAHA Flow Restrictor Fittings 0.75” x 0.75” FPT -See spec catalog 2 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 3 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 4 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 5 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 6 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 7 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 8 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -See spec catalog 9 GPM for flow rate Flow Restrictor Fitting 0.75” x 0.75” FPT -- 10 See spec catalog GPM for flow rate 0.25” MPT Brass PT Plug All 0.50” MPT Brass PT Plug All Stainless Steel Flow Meter -- 1 to 10 GPM Refer to spec catalog Stainless Steel Flow Meter -- 1 to 17 GPM Refer to spec catalog
Geothermal Heat Pump Product Catalog
13 November 2011
Accessories REPLACEMENT/OPTIONAL FILTERS • Filters- Conventional paper pleat type filter cartridge, available in case quntities. •Electrostatic Filter- Self charging multi-layer filter, washable. Fits into existing filter tracks on the RXT Heat Pump. •Dynamic Air Cleaner- Electronic polarized media filter. This unit includes an activated charcoal screen and an active electrostatic field. External 24VDC power required. •Replacement media packaged in quantity of three each. Fits into existing filter tracks on the RXT Heat Pump. Part #
Description
Tons/Compatibility Nomenclature
Weight lbs (kg) w/ pkg.
2380009086
(RXT024 – 036)
APAF2830A
1.7 (.77)
(RXT048 – 072)
APAF2834A 1.75 (.8)
(RXT024- 036) (RXT048- 072) (RXT024-036)
AEF2830A 8 (3.6) AEF2834A 8 (3.6) AEAC2830 7.3 (3.3)
(RXT048-072)
AEAC2834 7.8 (3.5)
2380009092
28” x 30” x 1” Pleated Air Filter, case of 12 28” x 34” x 1” Pleated Air Filter, case of 12 28” x 30” x 1” Electrostatic Air Filter 28” x 34” x 1” Electrostatic Air Filter 28” x 30” x 1” Dynamic Electronic Air Cleaner 28” x 34” x 1” Dynamic Electronic Air Cleaner Replacement Media (3 Pack)
for AEAC2830
ACRM2830 10 (3.18)
2380009093
Replacement Media (3 Pack)
for AEAC2834
ACRM2834 10 (3.18)
2380009087 2380009088 2380009089 2380009090 2380009091
FILTER RACK (HYDRONIC AIR HANDLERS ONLY)
Part #
Description
Tons/ Compatibility
Nomenclature
Weight lbs (kg) w/ pkg.
2380009094 2380009095
Small Filter Rack Medium Filter Rack
MPH024 MPH036
AMPFILTERS AMPFILTERM
6 (2.7) 7 (3.2)
2380009096
Large Filter Rack
MPH042-060
AMPFILTERL
8 (3.6)
Geothermal Heat Pump Product Catalog
14
November 2011
Accessories MISC. INSTALLATION ACCESSORIES Part #
Description
Tons/Compatibility Nomenclature
Weight lbs (kg) w/ pkg.
2380009079
0.5” Check Valve (Sweat)
ACV3A
1 (.5)
2380009080
0.75” Check Valve (Sweat)
ACV4A
1 (.5)
2380009081
EZ-Trap 0.75” Kit
ACDT1A
1 (.5)
2380009082 2380009083 2380009114
Hard Start Kit Hard Start Kit Soft Start Kit
ASK1A ASK2A AKSSSA
1 (.5) 1 (.5) 1 (.5)
2380009115
Soft Start Kit
Desuperheater Installation Desuperheater Installation 1.5 - 6 ton waterto-air 1.5 to 3 ton units 3.5 to 6 ton units 2 through 3.5 tons 4 through 6 tons
AKSSLA
1 (.5)
SOFTWARE •Loop sizing and pressure drop calculations •Unit sizing with bin data report options •Flow center pump selection and curve reports •Economic comparison Geo vs Fossil fuel systems and payback period •Proposal package •Based directly on IGSHPA loop and system sizing algorithms
Part #
Description
Tons/ Compatibility
Nomenclature
2380010000
Geoanalyst- Geothermal Heat Pump Sizing and Selection Software
N/A
1 (.5)
Geothermal Heat Pump Product Catalog
15 November 2011