City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force

FLORIDA BUILDING CODE COMMERICAL CHECKLIST PROJECT IDENTIFICATION: CONTRACTOR: ARCHITECT: STRUCTURAL ENGINEER OF RECORD: CIVIL ENGINEER OF RECORD: PLUMBING ENGINEER OF RECORD: MECHANICAL ENGINEER OF RECORD: ELECTRICAL ENGINEER OF RECORD: FIRE PROTECTION ENGINEER OF RECORD: LEED PROFESSIONAL: PROJECT SCOPE:

PERMIT NO:

CONSTRUCTION TYPE USE & OCCUPANCY CLASSIFICATION(S) CODE REQUIREMENTS ALLOWABLE BLDG HEIGHTS AND AREAS BLDG HEIGHT MODIFICATION MEZZANINES BLDG AREA MODIFICATIONS OCCUPANT LOAD HORIZONTAL SEPARATION NUMBER OF EXITS REQUIRED FIRE PROTECTION – AUTOMATIC FIRE SPRINKLERS ALLOWABLE OPENINGS UNPROTECTED ALLOWABLE OPENINGS PROTECTED DESIGN WIND SPEED RISK CATEGORY EXPOSURE CATEGORY

PROJECT PARAMETERS

FBC Table 503 FBC Sec. 504 FBC 505 FBC Sec.506 Table 1004.1.1 FBC Table 601 FBC Sec. 1015 FBC 903.2 FBC Table 705.8.3 FBC Table 705.8.2 ASCE 7-10 ASCE 7-10 ASCE 7-10

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force FIRE RESISTANCE RATINGS STRUCTURAL FRAME BEARING WALLS - INTERIOR BEARING WALLS - EXTERIOR NON-BEARING WALLS & PARTITIONS – INTERIOR NON-BEARING WALLS & PARTITIONS - EXTERIOR FLOOR CONSTRUCTION ROOF CONSTRUCTION Existing Building Classification of Work

FBC Table 601 FBC Table 601 FBC Table 601 FBC Table 601 FBC Table 602 FBC Table 601 FBC Table 601 EBC Chapter 4

BUILDING INFORMATION CROSS REFERENCE SITE REQUIREMENTS ITEM Parking Fire access Vehicle loading Driving/turning radius Fire hydrant/water supply/post indicator valve (PIV) Set back/separation (assumed property lines) Location of specific tanks, water lines and sewer lines

REFERENCE

SHEET NUMBER

REVIEWED BY:

SHEET NUMBER

REVIEWED BY:

FAC 403.5.1 FBC 402.17 FFPC 18.2.3 FBC Sec. 406 FBC Sec. 406 FFPC 18.3 FBC Chap. 5 FPC Chap.6, & 7

FIRE-RESISTANT CONSTRUCTION – Chapter 7 ITEM Fire-resistant separations (Wall type designations) Protection of openings details Fire blocking and draft-stopping details

REFERENCE FBC 705/706 FBC 715 FBC 717

Penetrations of rated walls (Fire-stopping details)

FBC 713

Calculated fire resistance

FBC 721

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force

FIRE SUPPRESSION SYSYTEMS – Chapter 9 ITEM Early warning smoke evacuation systems Schematic fire sprinklers Standpipes Pre-engineered systems Riser diagram

REFERENCE FBC 909 FBC 903 FBC 905 FBC 903 FBC 903

SHEET NUMBER

REVIEWED BY:

REFERENCE FBC 1004 FBC 909 FBC 909 FBC 909.20.5 FBC 911.1(12)

SHEET NUMBER

REVIEWED BY:

REFERENCE

SHEET NUMBER

LIFE SAFETY SYSTEMS SHEET NUMBER ITEM Occupant load and egress capacities Early warning Smoke control Stair pressurization Systems schematic

OCCUPANCY LOAD/EGRESS – Chapter 10 ITEM Occupancy load Gross Net Means of egress Exit access Exit Exit discharge Stairs construction/geometry and protection Doors Emergency lighting and exit signs Specific occupancy requirements Construction requirements Horizontal exits/exit passageway

REVIEWED BY:

FBC 1004 FBC 1002.1 FBC 1002.1 FBC 1002.1 FBC 1014 FBC 1015 FBC 1027 FBC 1009 FBC 1008 FBC 1006 FBC Table508.4 FBC Table 601 FBC 1023/1025

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force

STRUCTURAL REQUIREMENTS ITEM Soil conditions/analysis Termite protection Design loads Wind requirements Building envelope Structural calculations (if required) Foundation Wall systems Floor systems Roof systems Threshold inspection plan Stair systems

REFERENCE

SHEET NUMBER

REVIEWED BY:

SHEET NUMBER

REVIEWED BY:

FBC 1803 FBC 1816 FBC 1606/1607 FBC 1609 FBC 1403 FBC 1603 FBC 1808 FBC Table 601 FBC Table 601 FBC Table 601 FBC 110.3.7.1 F.S. 553.71 FBC Sec. 1009

MATERIALS ITEM Wood Steel Aluminum

REFERENCE FBC Chap. 23 FBC Chap. 22 FBC Chap. 20

Concrete

FBC Chap. 19

Plastic Glass Masonry Gypsum board and plaster Insulating (mechanical)

FBC Chap. 26 FBC Chap. 24 FBC Chap. 21 FBC Chap. 25 FMC 604 Duct FMC 1204 Pipe FBC 1507 FBC Chap. 13

Roofing Insulation

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force

2012 FLORIDA ACCESSIBILITY CODE FOR BUILDING CONSTRUCTION ITEM Site requirements Accessible route Vertical accessibility Toilet facilities Bathing facilities Drinking fountains Equipment Special occupancy requirements Disproportionate Cost Fair housing requirements

REFERENCE FAC Chap. 5 FAC Sec. 402 FAC Sec. 201.1.1 FAC Sec. 213 FAC Sec. 213 FAC Sec. 602 FAC Sec. 810 FAC Ch. 2 FAC Sec. 202.4.1 FAC Part 3,Sec 3

SHEET NUMBER

REVIEWED BY:

REFERENCE FBC Chap. 8 FBC 1205 FBC 1203 FPC Chap. 7

SHEET NUMBER

REVIEWED BY:

REFERENCE FBC Chap. 30,FAC Sec. 407 FBC Sec. 3005 FAC Sec. 410

SHEET NUMBER

REVIEWED BY:

REFERENCE FBC 424.1.3.1.9 FBC 424.1.8 FBC 424.1.7

SHEET NUMBER

REVIEWED BY:

INTERIOR ITEM Interior finishes (flame spread/smoke development) Light Ventilation Sanitation

SPECIAL SYSTEMS ITEM Elevators Escalators Lifts

SWIMMING POOLS ITEM Barrier requirements Spas Wading pools

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force

ELECTRICAL INFORMATION CROSS REFERENCE ITEM Wiring Services Feeders and branch circuits Overcurrent protection Grounding Wiring methods and materials GFCIs

REFERENCE NEC 300 NEC 230 NEC 225 NEC 240 NEC 250 NEC 300 &400 NEC 210.8

Equipment/Panels Special occupancies Special Conditions

NEC 110 NEC Chap. 5 NEC Chap.7

Communication systems Low voltage, Remote-Control, Signaling Load calculations

NEC 800 NEC 725 NEC 220

SHEET NUMBER

REVIEWED BY:

PLUMBING INFORMATION CROSS REFERENCE ITEM Minimum plumbing facilities Fixture requirements Water supply piping Sanitary drainage Water heaters

REFERENCE FPC 403 FPC Table 403.1 FPC 601 FPC 701 FPC 501

SHEET NUMBER

REVIEWED BY:

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force Vents Roof drainage Back flow prevention Irrigation Location of water supply line Grease traps Environmental requirements Plumbing riser

FPC 901 FPC 1101 FPC 608.13 Appendix-F FPC 603.2 FPC 1003 FPC 605

MECHANICAL INFORMATION CROSS REFERENCE ITEM Energy calculations

Exhaust systems Clothes dryer exhaust Kitchen equipment exhaust/Fire Suppression Specialty exhaust systems Equipment Equipment location/Guards/Condensate Disposal Make-up air Roof-mounted equipment/ Roof Access

REFERENCE FBC Energy Conservation Ch. 5 FMC Chapt.5

SHEET NUMBER

REVIEWED BY:

FMC 504 FMC 505,507,509 FMC 510 FMC Chap. 3 FMC 303, 304.11, 307 FMC 403.3 FMC 504.5 FMC 301.12 FBC 1509.7 FMC 306.5

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements

City of Rockledge – BOAF / AIA-Florida / FES Joint Task Force Duct systems Ventilation Combustion air Chimneys, fireplaces and vents Appliances Boilers Refrigeration Bathroom ventilation Laboratory

FMC Chap. 6 SMACNA FMC Chap 4 FMC Chap 7 Appendix A FMC Chap 8 FGC Chap 5 FMC Chap 9 FMC Chap 10 FMC Chap 11 FMC 403.3 FMC 510.1

GAS INFORMATION CROSS REFERENCE ITEM Gas piping Venting Combustion air Chimneys and vents Appliances Type of gas

REFERENCE FGC 402 FGC 502.1 FGC 304 FGC 501 FGC 601 FGC 401

Fireplaces LP tank location

FGC 605 NFPA 58-2008 Edition FGC 401

Riser diagram/shutoffs

SHEET NUMBER

REVIEWED BY:

This document is based on the minimum requirements of 2010 Edition of the Florida Building Code Complete and submit this document with your Building Permit application to assist the plans examiners with their reviews Check with the building department having jurisdiction for any additional requirements