DOCUMENT ADDENDUM NO. 1 October 7, 2016

DOCUMENT 00 00 11 ADDENDUM NO. 1 October 7, 2016 South Rivanna WTP - Raw Water Pump Station Leaf Screen Replacements RFB No. 329 Rivanna Water and Sew...
Author: Corey Hamilton
6 downloads 0 Views 303KB Size
DOCUMENT 00 00 11 ADDENDUM NO. 1 October 7, 2016 South Rivanna WTP - Raw Water Pump Station Leaf Screen Replacements RFB No. 329 Rivanna Water and Sewer Authority - Albemarle County, VA SEH No. RIVAN 137835

From:

Short Elliott Hendrickson Inc. 3535 Vadnais Center Drive St. Paul, MN 55110-5196 651.490.2000

To:

Document Holders

DOCUMENT HOLDERS on the above-named project are hereby notified that this document shall be appended to, take precedence over and become part of the original bidding documents dated September 26, 2016 for this work. Bids submitted for the construction of this work shall conform to this document. This addendum consists of one page and attached Document No. 00 31 33 - Hoist Beam Certification (one page), and supporting letter report.

Changes to Bidding Requirements: 1.

Add Document No. 00 31 33 - Hoist Beam Certification.

2.

Add supporting letter report for Document 00 31 33 - Hoilst Beam Certification. Beam Evaluation Report by Dunbar Milby W illiams Pittman & Vaughan, consisting of two pages.

Note:

Receipt of this Addendum No. 1 (dated October 7, 2016) shall be acknowledged on Page 2 of 7 of the submitted Bid Form. Failure to do so may subject Bidder to disqualification.

END OF ADDENDUM

RIVAN 137835

Addendum 00 00 11 -1

DOCUMENT 00 31 33 HOIST BEAM CERTIFICATION

PART 1 GENERAL 1.01

2016 SRWTP RWPS HOIST BEAM CAPACITY REPORT A.

This evaluation report, dated September 29, 2016, is included for the Bidders’ information. The evaluation was performed to estimate a safe working load capacity of the existing hoist beam. The Owner does not make any guarantees for the evaluation provided in the report.

B.

Contractor may use the existing hoist beam, measuring approximately 17’-10” from the concrete deck to the bottom of the beam, during construction. If the beam is damaged during construction, the Contractor shall be responsible for repair or replacement of the beam.

C.

Contractor shall not use the Owner’s existing hoist. If Contractor desires to use the existing hoist beam, Contractor shall provide a hoist for the removal of the leaf screen.

D.

The estimated weights of the proposed leaf screen sections are provided in Section 01 11 00. Owner and Engineer do not make any guarantees to the estimates provided. Contractor is to confirm weights of both the existing and proposed leaf screens prior to the removal of the existing leaf screen and installation of the proposed leaf screen.

END OF DOCUMENT

RIVAN 137835

Hoist Beam Certification 00 31 3 3 - 1

This Page Left Blank Intentionally

DUNBAR MILBY WILLIAMS PITTMAN & VAUGHAN C o n s u l t in g S tr u c t u r a l E n g i n e e r s RICHMOND AND CHARLOTTESVILLE 110 T hird S tre et , N .E., C harlottesville , Virginia 2 2 9 0 2 - 5 2 2 4 KENNETH J . PUTMAN, PE, S E C B EDWARD S . FRAHER, III, PE, S E C B STEPHEN D. BARBER, PE, S E C B JEFFREY S . DAVIS, PE, S E C B , LEED AP BD+C GREGORY C. ELLEN, PE, S E C B

P h o n e : 4 3 4 2 9 3 -5 1 7 1

F ax : 4 3 4 9 7 1 -5 1 9 1

SENIOR ASSOCIATES

S e p t e m b e r 29, 2 0 1 6

CONSULTANTS C. NELSON WILLIAMS, IV, PE, S E C B R. LINDLEY VAUGHAN, JR ., PE, S E C B

DONNA E. ADAMS, PE, S E C B RICHARD K. HAYS, PE, S E , M LSE MARGIN J . KOTAS, PE AARON J . RICKEL, PE ROBERT L. SMUH, PE, S E C B BETTY M. THOMPSON

Mr. Scott Schiller, PE Rivanna W a te r a n d S e w e r A uthority 695 M o o re s Creek Lane Charlottesville, VA 22902 Re:

Hoist Beam Capacity a t S outh Rivanna River Dam Charlottesville, Virginia DMWPV Job No. 1609-30

Dear Scott, As r e q u e s te d , w e have p e r f o r m e d a stru c tu ra l ev alu atio n o f t h e existing steel hoist b e a m a b o v e t h e leaf sc re e n s a t t h e South Rivanna River Dam facility. W e visited t h e site to o b s e rv e t h e physical condition o f t h e b e a m an d its s u p p o rts, a n d p e r f o r m e d a q u a n tita tiv e analysis o f t h e b e a m a n d its su p p o rts. The analysis w a s b a s e d on in fo rm a tio n for b e a m size, span, s u p p o r t conditions, e tc as indicated in t h e record draw in gs from 1964 t h a t you provided. T he steel b e a m is e x p o s e d t o t h e w e a t h e r a n d is lightly c o rro d e d . W e o b s e r v e d s o m e su rface pitting, b u t n o t significant d e la m in a tio n . W e e s tim a te t h a t 1 /16 " of section loss is p r e s e n t in t h e t o p a n d b o tto m flanges o f t h e b e a m a n d w e u se d this value in c o m p u tin g t h e b e a m section p ro p e rtie s. T he s u p p o rtin g h a n g e r rods a r e also sho w ing signs o f corrosion a n d w e c o n sid e re d s o m e sec tio n loss in th e s e m e m b e r s to o . The su p p o rtin g c o n c re te b e n ts a p p e a r to b e in g o o d condition. M aterial s tr e n g th s w e r e n o t indicated in t h e draw ings provided. T h e re fo re , w e a s s u m e d t h e following values w hich w e r e typical of t h e c o n stru c tio n of t h e tim e: Structural steel yield s tre n g th : Reinforcing steel yield s tre n g th : C o n c re te c o m p re ssiv e stre n g th :

3 3,0 00 psi 40 ,0 0 0 psi 3 ,0 0 0 psi

Based on t h e a b o v e a ss u m p tio n s , w e e s ti m a te a safe w orking load capacity for t h e hoist b e a m to b e 7 ,0 00 # a t this tim e.

www.dm wpv.com

M r. S cott Schiller, PE S e ptem be r 29, 2016 Page 2 o f 2

If you have any questions o r if w e can assist fu rth e r, please co n ta c t us. Very tru ly yours, D u n b a r M ilb y W illia m s P ittm a n & Vaughan

Stephen D. Barber, P.E.

o u

STEPHEN D. BARBER CERTIFICATE NO.

L

025731 9 /2 9 /1 6

DUNBAR, MILBY, WILLIAMS, PITTMAN & VAUGHAN, PLLC

R ichm ond/C ha rlottesville