DMS 903. Goniometer System. for complete display characterization. Two Global Leaders. One Complete Solution

DMS 903 Goniometer System for complete display characterization Two Global Leaders. One Complete Solution. Our story Two Global Leaders. One Com...
Author: Whitney Wheeler
22 downloads 0 Views 2MB Size
DMS 903

Goniometer System

for complete display characterization

Two Global Leaders. One Complete Solution.

Our story

Two Global Leaders. One Complete Solution. Konica Minolta Sensing Americas provides advanced optical technology that precisely measures the elements of color and light. Their products have become a staple in research and manufacturing environments, helping organizations to meet product quality and operational goals with less waste, time, and effort. This commitment to creating value for customers is the core principle behind the Konica Minolta brand, and has led them to develop the world’s first portable spectrophotometer and the first light meter used on board a spacecraft (Apollo 8). It’s also the driving force behind the high level of quality and precision built into each of their products. These are some of the reasons why Konica Minolta is regarded as the technological leader in color and light measurement solutions today.

Based in Germany, Instrument Systems develops and produces high-quality optical test and measurement instruments for a broad spectrum of applications. Their extensive product range includes spectrometers, imaging photometers and colorimeters, goniophotometers, integrating spheres, and turnkey system solutions. Instrument Systems is dedicated to working with standardization committees and associations such as ICDM and CIE. They also cooperate with leading national metrology institutes. Now, these two experts have combined their knowledge and tools together to offer the complete solution for the most accurate measurement of light and color available in the market today.

We bring quality to light.

Key features at a glance 





 



Measurement of emissive, transmissive, reflective and transflective displays up to 72" diagonal size 6 motorized axes for directional and lateral scanning, adjustment of height and light source inclination Comprising electrical driving, illumination, computer and software Fast photometer for analysis of temporal luminance variations DMSControl and ViPer software for automated measurement sequences and evaluation

The goniometer system DMS 903 is ideal for photometric and colorimetric analysis of emissive, transmissive, reflective, and transflective displays and modules up to a size of 72" diagonal. The turnkey solution is based on a fully motorized 6-axis goniometer for determining luminance, contrast, and color properties at different viewing angles and variable electrical driving. The measurement system is perfectly suitable for all applications in research and development, as well as quality control. The comprehensive range of illumination devices and temperature-control chambers makes the DMS 903 an ideal system for determining the characteristics of displays under various environmental and illumination conditions.

Options

Measurements

ì Spectrometer for radiometric, photometric and colorimetric analysis

ì Angular scan: variation of luminance, contrast and chromaticity with viewing direction for evaluation of directional uniformities and BRDF

ì Directional light sources for measurement of reflectance factor and in-plane BRDF ì Forced air temperature control of the display under test ì Interface for various video test-pattern generators

ì Area scan: scanning of display surface area for lateral uniformity evaluation ì EOC: variation of luminance, contrast and chromaticity with electrical driving for evaluation of EOTF-characteristics (e.g. gamma) ì Transients: luminance versus time for e.g. response time evaluation ì Reflectance characteristics under diffuse and directional illumination ì Customer specific measurements defined with DCI scripting sequences

We bring quality to light. System components The following components and accessories are included in the DMS 903 standard scope of delivery, if not explicitly marked as optional components or accessories. Temperature control:

Light measuring devices:

ì HCS-4 (optional): air-forced temperature control device, temperature range -30 °C to +85 °C, with integrated diffuse reflective illumination; optional extension: internal motorized stage for xy-scanning

ì PMT 3: fast photometer with photomultiplier tube, bandwidth 100 kHz, 500 kHz or 2 MHz

Light sources and illumination systems:

ì CAS 140CT (optional): model VIS; 360 to 830 nm; 1024 pixel back- illuminated CCD detector; 2.2 nm spectral resolution (100 μm slit); 0.5 nm/pixel data point interval (CAS140CT-151)

ì HEL-4: light source with halogenic incandescent lamp ì LC-8 (optional): xenon light source for higher light output ì DHS: diffusing hemisphere for evaluation of contrast of reflective displays ì DHS-HC (optional): diffusing hemisphere for evaluating the contrast of reflective displays; illumination geometry similar to HCS-3 ì PID (optional): collimated parallel beam illumination ì VADIS (optional): variable aperture diffuse illumination source for e.g. scattering characterization of surfaces (BRDF), measurement of reflectance factor

We bring quality to light. DUT driving: ì ASG: arbitrary signal generator with 1 or 4 analog output channels (depending on basic system variant); standard and user defined signal waveforms; for direct addressing, passive matrix driving and control of TFT arrays (gate and data signals), etc.; power amplifiers are available for different voltage and current ranges

Footprint

ì Source meter (optional): programmable current or voltage source with digital multimeter, in particular for current driven display devices like OLED displays; can be combined with a multiplexer (for driving and measurement of displays with multiple segments and matrix displays) ì DCI (optional): device control interface for scripting and communication with various external devices, e.g. video pattern generators, module drivers, power supplies, etc. via RS232, GPIB, USB, or TCP/IP

Software: ì DMSControl: administration, configuration and control of the instrument, definition and management of measurement sequences ì Visual performance evaluation (ViPer): evaluation and representation of measurement results (on- and off-line), data exchange with other software (e.g. spreadsheet applications) and report generation (e.g. PDF documents) ì Report generator (optional): user configurable data export from DMSControl to spreadsheet software

Scope of delivery The basic system comprises the following components: ì DMS 903 goniometer mechanism ì Microscope viewing optics ì Photometer PMT 3/100 ì GRU with ASG-1 (one channel) or ASG-4 (4 channel) and power amplifier PA 3/60 (DMS 903-1 or DMS 903-4) ì HEL-4 light source for reflective and transmissive illumination ì PC with table ì Software package: DMSControl, ViPer ì Light shielding box

Technical Data DMS 903 Axis

Scan range

Resolution

Inclination Theta

0 … 80°

0.1°

Rotation Phi

0 … 360°

0.1°

Reflective illumination

0 … 70°

0.1°

x translation

-300 … +300 mm

0.1 mm

y translation

-225 … +225 mm

0.1 mm

z translation

0 … 280 mm

0.1 mm

DUT dimensions Maximum size (L x W)

1300 mm x 1600 mm (72" diagonal for a 16:9 panel) for center measurement; 650 mm x 1100 mm (50" diagonal for a 16:9 panel) for full x-y scanning range

Maximum thickness

280 mm

Dimensions (Length x Width x Height)1 Mechanics of DMS 903

1900 mm x 1500 mm x 1860 mm

Electronics rack

750 mm x 600 mm x 1250 mm

Mass1 Mechanism

700 kg

Electronics rack

120 kg

Facility requirements

1

Mains voltage

200 V – 240 VAC (230 V nominal), 50 Hz, 1 phase

Max. mains current / fuse

30 A

Power consumption

Max. 1500 W (incl. PC, CCD and 2 x HEL-4)

All sizes and masses approximate

We bring quality to light.

Ambient operating conditions Ambient temperature

23 °C (±5 °C)

Humidity

0 – 60 % rel. humidity

Photometer PMT 3 Bandwidth

100 kHz (standard), 500 kHz or 2 MHz (optional)

Measurement spot diameter

0.5, 1, 2, 3, 5, 7, 10 mm

Spectrometer CAS 140CT Spectral range2

360 … 830 nm (usable spectral range depending on software used)

Spectral resolution

2.2 nm

Data point interval

0.5 nm

3

Measurement spot diameter 2 3

0.5, 1, 2, 3, 5, 7, 10 mm

DMSControl software range: 380 … 800 nm DMSControl data point interval: 1 nm

Ordering Information Order Number

Description

Basic system DMS-903-1

Model DMS 903-1 comprising: Goniometer with 6 motorized axes; microscope viewing optics; fast photometer PMT 3/100; 1 x HEL-4 light source; transmissive illumination; GRU with ASG-1 (1 channel) and power amplifier PA 3/60; light shielding enclosure; PC with table; DMSControl and ViPer software

DMS-903-4

Model DMS 903-4 comprising: Goniometer with 6 motorized axes; microscope viewing optics; fast photometer PMT 3/100; 1 x HEL-4 light source; transmissive illumination; GRU with ASG-4 (4 channels) and power amplifiers PA 3/60; light shielding enclosure; PC with table; DMSControl and ViPer software

Options - Temperature control DMS-3-50

HCS-4-32 temperature chamber with ThermoStream control unit

DMS-3-52

HCS-4-32m motorized positioning stage for HCS-4-32 temperature chamber

Options - Light sources and illumination systems DMS-5-10

HEL-4 light source with 150 W tungsten halogen lamp

DMS-5-12

LC-8 xenon light source for higher light output

DMS-5-21

PID-903 parallel illumination device (collimated beam)

DMS-5-31

VADIS-903 variable aperture diffuse illumination source for reflective measurement

DMS-5-42

DHS-HC9 diffusing hemisphere for evaluating the contrast of reflective displays; illumination geometry similar to HCS-3 source

Options – Light measuring devices DMS-1-10

CCD spectrometer set for DMS systems; incl. CAS 140CT VIS model (CAS140CT-151) 360 nm – 830 nm (usable spectral range depending on software used)

Options – DUT driving DMS-2-10

Keithley 2400 series source meter set for DMS, including cabling and interface

Options – Software DMS-SW-35

DCI device control interface for external devices (for DMSControl)

DMS-SW-40

Report generator for data export to Excel spread sheets

Contact information

Instrument Systems - Operating Globally, Acting Locally Instrument Systems is the premier company for light measurement. As a subsidiary company of Konica Minolta we have access to resources over the long term and to a global network – our mission is your solution, anytime and anywhere. World-class customer support is rewarded with customer loyalty - a top priority at Instrument Systems.

Neumarkter Str. 83 D-81673 München, Germany Phone: +49 (089) 45 49 43 - 0 Fax: +49 (089) 45 49 43 - 11 [email protected] www.instrumentsystems.com

Konica Minolta Sensing Americas Konica Minolta Sensing, Americas represents Instrument Systems in North America and Canada with a high level of expertise in marketing optical measuring instruments. High-quality customer support is based on a track record of close cooperation and constant exchange of information and know-how.

101 Williams Drive Ramsey, NJ 07446 USA Phone: 201-236-4300 Toll Free: 888-473-2656 Fax: 201-785-2480 [email protected] sensing.konicaminolta.us

In the interest of the continuous development and improvement of our products, we reserve all rights to make technical changes to the information contained in our printed material. Such changes, errata and printing mistakes do not constitute grounds for claims for damages. The LumiCam series of measurement cameras may only be used for luminance and chromaticity measurements of self-illuminating objects.

SAFETY PRECAUTIONS

For correct use and for your safety, be sure to read the instruction manual before using the instrument.

Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.

Certificate No : LRQ 09600941A Registration Date : March 3, 1995

Certificate No : JQA-E-80027 Registration Date : March 12, 1997