DIVISION 08 - DOORS AND WINDOWS PN DOOR HARDWARE PART 1 GENERAL 1.1 SCOPE

DIVISION 08 - DOORS AND WINDOWS PN 2011013 PART 1 GENERAL 1.1 SCOPE 08710 - DOOR HARDWARE A. This Section of the Specifications shall include all...
Author: Lynne Sherman
12 downloads 0 Views 388KB Size
DIVISION 08 - DOORS AND WINDOWS PN 2011013 PART 1

GENERAL

1.1

SCOPE

08710 - DOOR HARDWARE

A. This Section of the Specifications shall include all labor, materials, services, and equipment necessary for and reasonably incidental to the provision and installation of the work of this Section as indicated on the drawings and/or as herein specified. 1.2

REFERENCES A. AAMA 701 Specification for Pile Architectural Manufacturers Association. B. BHMA A156.1

Weather

Stripping;

American

American National Standard for Butts and Hinges.

-

C. BHMA A156.2 - American National Standard for Bored and Preassembled Locks and Latches. D. BHMA A156.3

-

American National Standard for Exit Devices.

E. BHMA A156.4

-

American National Standard for Door Controls - Closers.

F. BHMA A156.5 - American Associated Products. G. BHMA A156.6

National

Standard

for

Auxiliary

Locks

and

American National Standard for Architectural Door Trim.

H. BHMA A156.13

-

American National Standard for Mortise Locks & Latches.

I. BHMA A156.16

-

American National Standard for Auxiliary Hardware.

J. BHMA A156.18

-

American National Standard for Materials and Finishes.

K. Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames; Door and Hardware Institute (DHI). L. NFPA 80 - Standard for Fire Doors and Windows; National Fire Protection Association. M. UL 437 - Standard for Key Locks; Underwriters Laboratories Inc.

08710-1

DIVISION 08 - DOORS AND WINDOWS PN 2011013 1.3

08710 - DOOR HARDWARE

SUBMITTALS A. Product Data: Manufacturer's data for each different piece of hardware, with installation instructions. 1. Obtain approval prior to submittal of final schedule. B. Hardware Schedule: Show manufacturer's complete identification for every item for every door. 1. Cross-reference to item names and designations in contract documents. 2. Indicate door/frame materials and sizes. 3. Explain number codes and abbreviations. 4. Indicate hardware mounting heights or locations, those specified. 5. Indicate finish for each item. C. Keying Schedule:

Separate schedule showing how each lock is keyed.

D. Operation and Maintenance Data: 1.4

if different from

For operating parts and finishes.

QUALITY ASSURANCE A. Qualifications of Supplier: A supplier of architectural finish hardware who has been supplying hardware for at least 2 years and who employs an architectural hardware consultant (AHC). B. Hardware for Fire Rated Doors: Tested for compliance with NFPA 80. 1. Listing in current classification publications of the agencies will be considered evidence of acceptable testing: a. Underwriters Laboratories Inc. (UL). 2. Provide permanent labels on all hardware except the listing agency and conditions of the listing.

1.5

following

hinges, indicating

PROJECT CONDITIONS A. Sequence submittal of hardware schedule and door and frame submittals, allowing adequate time for review and resubmittal, if required, so that construction is not delayed; provide adequate information for review. B. Provide hardware installation templates to installers of hardware and to fabricators of other work, which is required to be prepared in the shop or factory for hardware installation. C. Coordinate shop drawings of other work so that proper preparation is made.

08710-2

DIVISION 08 - DOORS AND WINDOWS PN 2011013 D. Deliver

keys

to key

08710 - DOOR HARDWARE control

manufacturer

for

set-up of key control

system. 1.6

DELIVERY, STORAGE, AND HANDLING A. Deliver hardware at the times and to the locations required for timely installation.

1.7

MAINTENANCE A. Provide

all adjustment manufacturers.

and maintenance tools recommended by hardware

PART 2

PRODUCTS

2.1

GENERAL HARDWARE REQUIREMENTS A. In addition to requirements of the hardware schedule, comply with the requirements below. B. Fire-Rated Doors: Provide complying with NFPA 80.

2.2

hardware

of

types

and

quality

required

MATERIALS - GENERAL A. Manufacturers: 1. Obtain all items of each type from the same manufacturer. B. Manufacturer's Names and Trade Names: Display of names, logos, or other identification is acceptable on lock or hinge edge of door, but not where visible on either face of door. 1. Exception: 2. Exception:

Required fire labels. As directed by or acceptable to the architect. 3. Exception: Manufacturer's name or other identification on rim of lock cylinders. C. Fasteners: Provide hardware prepared by the manufacturer with fastener holes for machine screws, unless otherwise indicated. 1. Provide all fasteners required for secure installation. 2. Select fasteners appropriate to substrate and material fastened. 3. Use flathead Phillips screws unless otherwise indicated.

being

4. Use wood screws for installation in wood. 5. Use fasteners impervious to corrosion outdoors and on exterior doors. 6. Exposed screws: Match hardware finish.

08710-3

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

7. Where it is not possible to reinforce substrate adequately screws, use through-bolts with sleeves or use sex bolts.

for

8. Do not use where head or nut would be exposed on face of door, unless specifically indicated or made necessary by other requirements. 9. Finish exposed heads and nuts the same as hardware on that side of the door. 10.Use expansion shield anchors in concrete and masonry. D. Items specified with the same finish shall match as closely as possible using standard manufactured products. 1. Provide finishes matching BHMA A156.18 designations. 2.3

HINGES A. Butt Hinges:

Five-knuckle, flush-barrel hinges.

1. Stanley FBB179/Hager BB1279 2. McKinney TA2714-652 3. or equal 4. Comply with applicable requirements of BHMA A156.1. 5. Use standard weight hinges unless otherwise indicated. 6. Use full mortise hinges unless otherwise specified. 7. Hinge pins: Unless otherwise indicated: a. Use steel pins for steel hinges. b. Use stainless steel pins for nonferrous hinges. 8. Provide nonremovable pins or safety studs for out-swinging doors with keyed lock or exit only function. a. Provide nonrising pins for interior doors. b. Quantity:

Provide 3 hinges on each door.

B. Continuous Hinges: 1. Products: a. Roton 780-224HD b. Pemko CFM-HD c. or equal 2.4

LOCKS, LATCHES, AND BOLTS A. Mortise Locksets and Latchsets: 1. Comply with requirements Series 1000-630.

of

08710-4

BHMA

A156.13,

Operational

Grade

1.

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

2. Products: a. Yale AUE b. Corbin-Russwin NSM c. Schlage 06L d. or equal B. Bored Locksets and Latchsets: 1. Comply with requirements of BHMA A156.2, Series 4000, Grade 1. 2. Products: a. Yale AU5400 b. Corbin-Russwin 3600 NZD c. Schlage D Series d. Or equal C. Exit Devices:(for medium stile doors) 1. Products: a. Von Duprin 98 Series b. Yale 7000 x AU506 c. Monarch 17-C-Dane d. American Device 6000 x JL e. or equal 2. Comply with requirements of BHMA A156.3, Grade 1. 3. Style: Modern push-pad type. 4. Outside trim: Lever Handles. 5. Provide cylinder dogging on all exit devices. 6. Exception: Do not provide dogging on devices on doors in firewalls and smoke partition. D. Auxiliary Locks: 1. Comply with requirements of ANSI/BHMA A156.5, Grade 1. E. Strikes:

Provide strike for each latch bolt and lock bolt. 1. Finish to match other hardware on door. 2. Use wrought box strikes with curved lips unless otherwise indicated. 3. Open strike plates may be used on interior wood doorframes.

2.5

LOCK CYLINDERS AND KEYING A. Keying:

Obtain the owner's keying instructions. 1. Key each lock differently unless otherwise directed. 08710-5

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

2. Provide construction keying for locks on: a. All exterior doors. 3. Provide high-security cylinders for locks on: a. All exterior doors. 4. Provide removable-core, cylinders for locks on: a. All doors. b. Furnish and install all inserts. 5. Where construction keying is not available, provide temporary cylinders and replace with permanent cylinders at completion. B. Keys:

Nickel silver. 1. Stamp each key with manufacturer's change symbol. 2. Provide individual change key for each lock, which is not designated to be keyed alike with a group of related locks. 3. Provide 3 of each change key. 4. Each master key system: 5 master keys. 5. Each grandmaster key system: 5 grandmaster keys. 6. Extra blanks: 2 for each lock. a. 5 construction keys.

C. Key Cabinet: door. 1. Capacity:

Wall-mounted, for keys hung on hinged panels behind cabinet 150 percent of locks on project.

2. Provide key tags and hook labels. 3. Provide complete key control system, with cross-indexes, key gathering envelopes, and receipt forms, set up by key control manufacturer. 4. Provide lock for cabinet; key lock to other locks of this section. 5. Manufacturers: Products of the following manufacturers, provided they comply with requirements of the contract documents, will be among those considered acceptable: a. Telkee, Inc. b. Lund Equipment Company, Inc. c. or equal 2.6

DOOR CONTROL DEVICES A. Closers

-

General:

1. Use closers of only one manufacturer. 2. Adjust closer opening force to comply with applicable codes. 08710-6

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

B. Surface-Mounted Closers: 1. Comply with requirements of BHMA A156.4, Grade 1. 2. Parallel arms: Where specified. 3. Provide delayed-action feature (PT4F) at: a. Main entrance doors at Vestibules. b. Toilets. C. Finish: Metallic paint finish, color similar to metal hardware on same door. 1. On fire-rated wood doors, fasten with sex-bolts. D. Concealed Overhead Closers:

Concealed in frame.

1. Comply with requirements of BHMA A156.4, Grade 2. 2. Provide the following features: a. PT 8A: b. PT 8D: c. PT 8F:

7 degree checking control. Additional 50 percent adjustment in closing force. Field-adjustable hydraulic back check.

d. PT 8G: Built-in, factory-set dead stop. 3. Provide delayed-action feature at: a. All entrance doors. E. Wall/Floor-Mounted A156.16.

Stops/Holders:

1. Resilient bumpers:

Comply

with

requirements

of

ANSI

Gray.

2. Overhead Stops & Holders: 2.7

ARCHITECTURAL DOOR TRIM A. Push/pulls: 1. Push Plate: 2. Pull Handles: (Barrier-Free) 3. Push/Pull Bars: (Barrier-Free) a. Comply with requirements of BHMA A156.6. b. Provide concealed fasteners. c. Bolts and DP Strike: Manual 4251, Auto Type 25. d. DP Strike: L24021 (Bolts/Exit Devices)-626. e. Coordinator: Type 21 Stop Applied Coordinator-600. 4. Protection Plates: Stainless steel, 0.050 inch thick, satin finish (630). 5. Comply with requirements of BHMA A156.6. 08710-7

DIVISION 08 - DOORS AND WINDOWS PN 2011013 6. Kickplates:

08710

-

DOOR HARDWARE

8 inches high by 2 inches less than door width.

7. Mop plates:

4 inches high by 2 inches less than door width. 8. Armor plates: 48 inches high by 2 inches less than door width. 9. Bevel all edges. 1O.Fasten with countersunk flathead screws. 2.8

SEALS AND THRESHOLDS A. Weatherstripping: 1. At jambs and head: Replaceable bumper in surface-mounted extruded aluminum housing. a. Bumper: Vinyl or silicone; AAMA 701.2. 2. At bottom: Replaceable sweep in surface-mounted extruded aluminum housing. a. Sweep:

Woven nylon or polypropylene pile; AAMA 701.

3. Housing finish: B. Thresholds:

Natural anodized.

Ribbed aluminum.

J16130-627.

1. Select style to suit changes in elevation and to fit door hardware and frames. 2. Interlocking hook type threshold: Hook strip on bottom of door, interlocking with top lip of threshold. a. At doors that swing in, provide internal drain and drain pan. C. Sealant for Setting Thresholds: sealant. 2.9

Butyl-rubber or butyl-polyisobutylene

ADDITIONAL MATERIAL A. Contractor shall include in the Base Bid, the cost to furnish one (1) additional set of hardware (Hardware Set No. ) and install in door directed by Architect. Contractor shall not order additional material until directed by Architect.

PART 3

EXECUTION

3.1

PREPARATION A. Factory- or shop-prepare all work for installation of hardware.

3.2

INSTALLATION A. Follow hardware manufacturer's recommendations and instructions.

08710-8

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

B. Install surface-mounted items after substrates have been completely finished: install recessed items and recessed portions of items before finishes are applied and provide suitable, effective protection. 1. When surface-mounted items are installed before final finish, remove, store, and reinstall, or apply suitable effective protection. C. Mount at heights specified in the Door and Hardware Institute's "Recommended Locations for Architectural Hardware for Standard Steel Doors and Frames." 1. Exception(s): a. As required by applicable regulations. D. Install hardware in correct location, plumb and level. E. Reinforce substrates operation.

as

required

for

secure

attachment

F. Thresholds: Apply continuous bead of sealant to all before installing. 3.3

and

proper

contact surfaces

ADJUSTMENT A. Adjust each operation.

operable

unit

for

correct

function

and

smooth,

free

B. Adjust door closers to overcome air pressure produced by HVAC systems. C. If hardware adjustment is completed more than one month before substantial completion, readjust hardware not more than one week before substantial completion. 3.4

INSTRUCTION OF OWNER'S PERSONNEL A. Instruct the owner's personnel in operation and maintenance of hardware, including finishes.

3.5

CLEANING A. Clean hardware; clean other work soiled during hardware installation.

3.6

MANUFACTURER'S LIST OF ABBREVIATIONS HA

Hager

ST RO NA LC VO

Stanlley Roton National LCN Van Duprin 08710-9

DIVISION 08 - DOORS AND WINDOWS PN 2009037 SG SC NO

08710

-

DOOR HARDWARE

Sargent Schlage Norton

PART 4

MEASUREMENT AND PAYMENT

4.1

All costs for all work indicated in this specification section will be included in the Contractor's lump sum amount, unless indicated otherwise.

4.2

HARDWARE SETS SHALL BE AS FOLLOWS: Hardware Set #: 01 DO1 Opening to Have: Qty Description 3 HINGE CB168 4.5 x 4.5 1 MORTISE CYLINDER 10-42 MK-GMK 1 DEADBOLT (CLASSROOM) 48HO-R 1 PULL PLATE BF111 x 73C 4" x 16" x T/B x CFT 1 PUSH PLATE 70 6" x 20" .050 x CFC 1 DOOR CLOSER D-4551 x REG 1 MOP PLATE 4" x 1" LDW .050 B4E x CSK 1 KICK PLATE 8" x 2" LDW .050 B4E x CSK 1 WALL STOP 409 3 SILENCERS 608

Finish 652 630 626 630 630 689 630 630 630 RUB

Mfg STANLEY SARGENT BEST ROCKWOOD ROCKWOOD STANLEY ROCKWOOD ROCKWOOD ROCKWOOD ROCKWOOD

Finish 652 630 626 630 630 628 630 630 630 RUB

Mfg STANLEY SARGENT BEST ROCKWOOD ROCKWOOD STANLEY ROCKWOOD ROCKWOOD ROCKWOOD ROCKWOOD

Hardware Set #: 02 D02 Opening to Have: Qty Description 3 HINGE CB168 4.5 x 4.5 1 MORTISE CYLINDER 10-42 MK-GMK 1 DEADBOLT (CLASSROOM) 48HO-R 1 PULL PLATE BF111 x 73C 4" x 16" x T/B x CFTT 1 PUSH PLATE 70 6" x 20" .050 x CFC 1 DOOR CLOSER D-4990 & 2 ADA ACCESS SWITCHES WITH PUSH PLATE 1 MOP PLATE 4" x 1" LDW .050 B4E x CSK 1 KICK PLATE 8" x 2" LDW .050 B4E x CSK 1 WALL STOP 409 3 SILENCERS 608

08710-10

DIVISION 08 - DOORS AND WINDOWS PN 2011013

08710 - DOOR HARDWARE

Hardware Set #: 03 D05 & D06 Opening to Have: Qty 3 1 1 1 1 1 3

Description HINGE CB168 4.5 x 4.5 x NRP STOREROOM LOCKSET 93K7-D-14C-S3 x ABC x MX8 DOOR CLOSER D-4550 x REG MOP PLATE 4" x 1" LDW .050 B4E x CSK KICK PLATE 8" x 2" LDW .050 B4E x CSK WALL STOP 575 SILENCERS 500

Finish 652 626 689 630 630 630 GRAY

Mfg STANLEY BEST STANLEY BURNS BURNS BURNS BURNS

Finish 652 626 626 626 630 689 630 630 GRAY

Mfg STANLEY BEST BEST BEST PRECISION STANLEY BURNS BURNS BURNS

Hardware Set #: 04 - ATTIC STOCK Opening to Have: Qty Description 6 HINGE CB168 4.5 x 4.5 x NRP 2 RIM CYLINDER [IC] 1E72 x RP x ABC x MX8 1 DEADBOLT (CLASSROOM) 48HO-R 1 STOREROOM LOCKSET 93K7-D-14C-S3 x ABC x MX8 1 RIM EXIT DEVICE FL-2108 x V4908D 1 DOOR CLOSER D-4550 x REG 1 KICK PLATE 16" x 2" LDW .050 B4E x CSK 1 MOP PLATE 4" x 1" LDW .050 B4E x CSK 10 SILENCERS 500 END OF SECTION

08710-11