INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic lock is mounted to the underside of the cabinet housing or vertically inside the cabinet.
Electrical Specifications: Dual Voltage
12 or 24VDC
Power Consumption
360mA@12VDC 180mA@24VDC
LS Lock Status Sensor SPDT, 250mA@30VDC
Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock. +
1
-
2
24VDC
Power Supply
12VDC
}
N/O CLOSED WITH POWER & DOOR CLOSED
Voltage Jumper
COM N/C OPEN WITH POWER & DOOR CLOSED
Lock Status Switch
+ A/C MAINS
POWER SUPPLY
-
12VDC or 24VDC
SWITCH or ACCESS CONTROL
Test operation. After verifying proper operation, tighten all screws as shown. Install anti-tamper plugs over socket screws using a soft hammer to avoid damage to the housing.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd
REV B
06-15
Page 1
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email
[email protected]
STEP 1 FOLD TEMPLATE ALONG DOTTED LINE.
PLACE TEMPLATE AGAINST CABINET DOOR AND FRAME.
DRILL HOLES AS INDICATED ON TEMPLATE.
STEP 2 MOUNT THE ARMATURE PLATE TO DOOR USING (1 ) RUBBER WASHER SANDWICHED BETWEEN (2) STEEL WASHERS (THE RUBBER WASHER AND (2) STEEL WASHERS ARE INSTALLED ON THE MOUNTING BOLT BETWEEN THE ARMATURE PLATE AND DOOR).
STEP 3 INSTALL THE MOUNTING PLATE ADJUST THE MOUNTING PLATE SO THAT IT AND THE ARMATURE FORM A RIGHT ANGLE. INSTALL THE REMAINING MOUNTING SCREWS.
STEP 4 INSTALL MAGNET TO MOUNTING PLATE.
CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd
REV B
06-15
Page 2
3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail:
[email protected]
INSTALLATION INSTRUCTIONS E6200 SERIES MAGNETIC LOCK The E6200 Series magnetic lock is mounted to the underside of the header, on the stop side of the door.
Frame
Mounting Screws Armature
Outswing
Electrical Instructions: Use properly fused U. L. Listed Power Supply Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur. Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full wave bridge rectifier may be used. A significant drop will occur when using a full wave bridge rectifier. Any low voltage condition will cause erratic operation of the optional board sensor. When using a full wave bridge rectifier all access controls and/or release contacts must be located between the EMlock and rectifier to ensure quick release. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd
REV -
07-10
Electrical Specifications: Dual Voltage
12 or 24VDC
Power Consumption
.250mA@12VDC .125mA@24VDC
DS Door Status Sensor SPDT, 500mA@30VDC LS Lock Status Sensor SPDT, 2A@30VDC
Page 1
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email
[email protected]
1. Fold template as indicated on dotted line. For single doors locate template against the door and header on the lock jamb side of the frame. 2. Mark and drill holes as indicated by the template.
STEPS 1 & 2
3. Mount armature to door.
STEP 3
4. WIRING DETAILS: * ACCESS CONTROL(S)
(+) To Properly Fused DC Power source (-)
BOND SENSOR (BAS) WIRING (+) RED BLU BLK BRN (-)
12VDC CONFIGURATION
WIRE CONTACT COLOR
E6200 EMLOCK 12VDC @ .250 Amps
DESCRIPTION
YEL
N/O
GRN
COM
COMMON
ORG
N/C
NO/POOR BOND
GOOD BOND
DOOR POSITION SENSOR (DPS) WIRING * ACCESS CONTROL(S)
(+) To Properly Fused DC Power source (-)
(+) 24VDC CONFIGURATION RED BLU E6200 EMLOCK BLK BRN 24VDC @ .125 Amps (-)
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd
REV -
07-10
WIRE CONTACT COLOR
Page 2
WHT
N/O
GRY
COM
VIO
N/C
DESCRIPTION ACTIVATE WHEN DOOR OPEN
COMMON ACTIVATE WHEN DOOR CLOSED
5. Install magnet onto the header with the magnetic face towards the door side of the stop. Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.
STEP 5
6. Test operation. When all is operating properly, install antitamper plugs over socket head screws using a soft hammer to avoid damage to the housing.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd
REV -
07-10
Page 3
MODEL E6200
#1/4-20 x 2”
8.00 (203.20)
7.20 (182.88)
1.00 (25.40) 2.25 (67.15)
CL 4.00 (101.60)
.375 (9.525)
6.00 (152.40)
2.25 (67.15)
.50 (12.70) .75 (19.05)
1.84 (46.74)
2.875 (73.03) .64 (16.26)
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E6200.vsd
REV -
07-10
Page 4
2.75 (69.85)
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail:
[email protected]
INSTALLATION INSTRUCTIONS E1200 SERIES MAGNETIC LOCK
Interlocking Mounting Plate Quick Mount Interlocking Mounting Assembly
Frame
Mounting Screws Armature
Outswing
Electrical Instructions: Use properly fused U. L. Listed Power Supply Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur.
Electrical Specifications:
Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full wave bridge rectifier may be used. A significant drop will occur when using a full wave bridge rectifier.
Power Consumption
Any low voltage condition will cause erratic operation of the optional board sensor.
Dual Voltage
12 or 24VDC .500mA@12VDC 250mA@24VDC
DS Door Status Sensor SPDT, 500mA@30VDC LS Lock Status Sensor SPDT, 2A@30VDC
When using a full wave bridge rectifier all access controls and/or release contacts must be located between the EMlock and rectifier to ensure quick release. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd
REV A1
04-11
Page 1
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email
[email protected]
1. Inspect the frame header to determine if mounting accessories are required (refer to page 4). 2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the lock jamb side of the frame. 3. Mark and drill holes as indicated by the template.
STEPS 2 & 3
4. Mount armature to door.
STEEL WASHER 2X
STEP 4
5/16-18 SOC HD SCREW WITH 3/16 (5MM) ALLEN HEX
ARMATURE
REINFORCEMENT TUBE
1-3/4“ HOLLOW METAL DOOR
5/8“ DRILL
1/2” DRILL SEXNUT
RUBBER WASHER
HOLLOW METAL DOOR From Sexnut side of door, drill exactly 1/2” hole thru one metal thickness only. From Armature side of door, drill 5/8” hole to insert reinforcement tube. Press in sexnut and reinforcement tube all the way and mount armature to door using hardware provided.
5. Install magnet onto the header with the magnetic stripes towards the door side of the stop. Assure that the magnet and armature line up properly, then tighten down ALL mounting screws.
STEP 5
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd
REV A1
04-11
Page 2
6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the door. Tap with a soft hammer to ensure proper alignment and engagement. CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
STEP 6
7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock. SWITCH or ACCESS CONTROL 2 3 - NO
A/C MAINS
4 C
Lock Status Switch (Relay)
+
1 +
Power Supply
5 6 NC NO 7 8 C NC
Door Position Sensor
POWER SUPPLY
-
12VDC or 24VDC
R G B W
ATTACH THE RED SIDE OF THE CONNECTOR HERE FOR A GREEN LED ENERGIZED & SECURE (RED=ENERGIZED & UNSECURE)
G B R
LED
RED GRN ATTACH THE GREEN SIDE OF THE CONNECTOR HERE FOR A RED LED ENERGIZED AND UNSECURE (GREEN=ENERGIZED & SECURE)
Voltage Jumper
12VDC
24VDC
Door Position Sensor (Reed switch) NC COM RED (open with door closed) BLACK GREEN (closed with door closed) NO
8. Test operation. When all is operating properly, tighten all screws as shown. Install security pins and screws as shown. Install anti-tamper plugs over socket head screws using a soft hammer to avoid damage to the housing.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd
REV A1
04-11
Page 3
MOUNTING ACCESSORIES:
STOP FILLER PLATE EF02 Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D
GLASS DOOR ARMATURE BRACKET E12U For use with Model E600 Series Field adjustable for glass thickness
ANGLE BRACKET E12L Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D
TOP JAMB MOUNTING BRACKET E12Z For use with Model E1200 Series
ADJUSTABLE ANGLE BRACKET E12A For use with Model E1200 Series
Supplied Mounting Hardware
To maintain surface plating from corrosion: Do not touch the lock face with your hands. Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper). Apply a thin film of rust inhibitor (LPS-3) on lock face. Repeat application on armature plate.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E1200.vsd
REV A1
04-11
Page 4
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 • Fax: (805) 494-8861 www.sdcsecurity.com • E-mail:
[email protected]
INSTALLATION INSTRUCTIONS E600 SERIES MAGNETIC LOCK The E600 Series magnetic lock is mounted to the underside of the header, on the stop side of the door. An inswing mounting kit (optional) can be used when mounting on the hinge side of the door.
Interlocking Mounting Plate Quick Mount Interlocking Mounting Assembly
Frame
Mounting Screws Armature
Outswing
Electrical Instructions: Use properly fused U. L. Listed Power Supply
Electrical Specifications: Do not install a diode in parallel with any magnetic lock. A diode will cause a delay when releasing the door and residual magnetism to occur.
Dual Voltage
12 or 24VDC
Power Consumption Although SDC recommends the use of a DC power supply, a transformer with an adjacent mounted full wave bridge rectifier may be used. A significant drop will occur when using a full wave bridge rectifier.
500mA@12VDC 250mA@24VDC
DS Door Status Sensor SPDT, 500mA@30VDC LS Lock Status Sensor SPDT, 2A@30VDC
Any low voltage condition will cause erratic operation of the optional board sensor. When using a full wave bridge rectifier all access controls and/or release contacts must be located between the magnetic lock and rectifier to ensure quick release. P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd
REV A1
04-11
Page 1
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email
[email protected]
1. Inspect the frame header to determine if mounting accessories are required (refer to page 4). 2. Fold template as indicated on dotted line. For single doors locate template against the door and header on the lock jamb side of the frame. 3. Mark and drill holes as indicated by the template.
STEPS 2 & 3
4. Mount armature to door.
STEP 4
STEEL WASHER 2X
5/16-18 SOC HD SCREW WITH 3/16 (5MM) ALLEN HEX
ARMATURE
REINFORCEMENT TUBE
1-3/4“ HOLLOW METAL DOOR
5/8“ DRILL
1/2” DRILL SEXNUT
RUBBER WASHER
HOLLOW METAL DOOR From Sexnut side of door, drill exactly 1/2” hole thru one metal thickness only. From Armature side of door, drill 5/8” hole to insert reinforcement tube. Press in sexnut and reinforcement tube all the way and mount armature to door using hardware provided.
5. Install mounting plate to header with the interlock detail away from the door side of the stop. Loosely fasten screws through adjustment slot as shown. Assure that the mounting plate and armature line up properly, then tighten down ALL mounting screws.
STEP 5
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd
REV A1
04-11
Page 2
6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the door. Tap with a soft hammer to ensure proper alignment and engagement. CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
STEP 6
7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock. 1
Lock Status Switch
4
Door Position Sensor (Reed switch) NC COM RED (open with door closed) BLACK GREEN (closed with door closed) NO
5
NO C NC
2 3
+ -
Power Supply
LED 24VDC
Voltage Jumper
12VDC
A RED LED INDICATES ENERGIZED & UNSECURED (GREEN=ENERGIZED & SECURE)
+ A/C MAINS
POWER SUPPLY
-
12VDC or 24VDC
SWITCH or ACCESS CONTROL
8. Test operation. When all is operating properly, tighten all screws as shown. Install anti-tamper plugs over socket head screws using a soft hammer to avoid damage to the housing.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd
REV A1
04-11
Page 3
MOUNTING ACCESSORIES: STOP FILLER PLATE EF02 Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D May be field cut for use with E600
GLASS DOOR ARMATURE BRACKET E6U For use with Model E600 Series Field adjustable for glass thickness
ANGLE BRACKET E12L Inches: 10.5" L x 0.5" H x 0.75" D mm: 266 L x 12.7 H x 19 D May be field cut for use with E600
TOP JAMB MOUNTING BRACKET E6Z For use with Model E600 Series
ADJUSTABLE ANGLE BRACKET E6A For use with Model E600 Series
Supplied Mounting Hardware
To maintain surface plating from corrosion: Do not touch the lock face with your hands. Clean lock face with Scotch-Brite pad by 3M (do not use sandpaper). Apply a thin film of rust inhibitor (LPS-3) on lock face. Repeat application on armature plate.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E600.vsd
REV A1
04-11
Page 4
801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail:
[email protected]
INSTALLATION INSTRUCTIONS E300 SERIES MAGNETIC CABINET/DISPLAY CASE LOCK The E300 Series magnetic lock is mounted to the underside of the cabinet housing or vertically inside the cabinet.
Electrical Specifications: Dual Voltage
12 or 24VDC
Power Consumption
360mA@12VDC 180mA@24VDC
LS Lock Status Sensor SPDT, 250mA@30VDC
Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock. 1
+ -
2
Power Supply
Voltage Jumper
24VDC
12VDC
Lock Status Switch BLACK
COM
NC NO
RED (open with power and door closed) GREEN (closed with power and door closed)
+ A/C MAINS
POWER SUPPLY
-
12VDC or 24VDC
SWITCH or ACCESS CONTROL
Test operation. After verifying proper operation, tighten all screws as shown. Install anti-tamper plugs over socket screws using a soft hammer to avoid damage to the housing.
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd
REV A
04-11
Page 1
Any suggestions or comments to this instruction or product are welcome. Please contact us through our website or email
[email protected]
STEP 1 FOLD TEMPLATE ALONG DOTTED LINE.
PLACE TEMPLATE AGAINST CABINET DOOR AND FRAME.
DRILL HOLES AS INDICATED ON TEMPLATE.
STEP 2 MOUNT THE ARMATURE PLATE TO DOOR USING (1 ) RUBBER WASHER SANDWICHED BETWEEN (2) STEEL WASHERS (THE RUBBER WASHER AND (2) STEEL WASHERS ARE INSTALLED ON THE MOUNTING BOLT BETWEEN THE ARMATURE PLATE AND DOOR).
STEP 3 INSTALL THE MOUNTING PLATE ADJUST THE MOUNTING PLATE SO THAT IT AND THE ARMATURE FORM A RIGHT ANGLE. INSTALL THE REMAINING MOUNTING SCREWS.
STEP 4 INSTALL MAGNET TO MOUNTING PLATE.
CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd
REV A
04-11
Page 2