Disclosure to Promote the Right To Information Whereas the Parliament of India has set out to provide a practical regime of right to information for citizens to secure access to information under the control of public authorities, in order to promote transparency and accountability in the working of every public authority, and whereas the attached publication of the Bureau of Indian Standards is of particular interest to the public, particularly disadvantaged communities and those engaged in the pursuit of education and knowledge, the attached public safety standard is made available to promote the timely dissemination of this information in an accurate manner to the public. “जान1 का अ+धकार, जी1 का अ+धकार”
“प0रा1 को छोड न' 5 तरफ”
“The Right to Information, The Right to Live”
“Step Out From the Old to the New”
Mazdoor Kisan Shakti Sangathan
Jawaharlal Nehru
IS 3232 (1999): Recommendations on Graphical Symbols for Process Flow Diagrams, Piping and Instrumentation Diagrams [MED 17: Chemical Engineering Plants and Related Equipment]
“!ान $ एक न' भारत का +नम-ण” Satyanarayan Gangaram Pitroda
“Invent a New India Using Knowledge”
“!ान एक ऐसा खजाना > जो कभी च0राया नहB जा सकता ह” है” ह Bhartṛhari—Nītiśatakam
“Knowledge is such a treasure which cannot be stolen”
IS 3232:1999 (Reaffirmed 2005)
Indian Standard RECOMMENDATIONS~ON GRAPHICAL SYMBOLS FOR PROCESS FLOW DIAGRAMS, PIPING AND INSTRUMENTATION DIAGRAMS
(Second Revision )
ICS01.080.30; 23.040.01
Q BIS1999 BUREAU OF MANAK BHAVAN,
Dccemhe,1999
INDIAN STANDARDS 9 BAHADUR SHAH ZAFAR MARG NEW DELHI 110002
Price Group 12
Chemical Engineering Plants and Related Equipment Sectional Committee, MED 17
FOREWORD This Indian Standard (Second Revision) was adopted by the Bureau of Indian Standards, after the draft finalized by the Chemical Engineering Plants and Related Equipment Sectional Committee had been approved by the Mechanical Engineering Division Council (MEDC). This Indian Standard was first brought out in 1965 and then revised in 1976 to make it more comprehensive and systematic. The first revision was based on DIN 28004 Bl.3. (1971) which has now been revised as DIN 28004 : 1988. Keeping in view the developments that have taken place over these years in the process equipments and chemical plants, it was decided to revise this standard. In this revision, the requirements of Graphical symbols for pipe lines and instruments given in IS 9446 : 1980 are also being covered. Therefore, IS 3232 is retitled as ‘Recommendations on graphical symbols for process flow diagram, piping and instrumentation diagrams’. After the publication of this standard IS 9446 : 1980 shall be treated as withdrawn. Process flow diagrams are widely used in chemical industry as an aid to show basic items of major equipments and their relations to one another in the process scheme. The important flow lines are indicated as connecting items of equipments and help to describe how the process operates. Piping and instrumentation diagrams are used in the chemical industry to indicate all important aspects such as: -
All equipment items All instrument items All pipelines Important aspects such as insulations, slopes, equipment elevations, etc
This second revision of IS 3232 is based on the following:. a) IS 3232 : 1976, b) IS 9446 : 1980, c) Prevailing practices existing in leading design engineering organization in the country, and d) Instrumentation symbols are in line with Instrument Society of America (ISA) stipulations.
IS 3232 : 1999
Indian Standard REC~OMMENDATIONS ON GRAPHICAL SYMBOLS FOR PROCESS FLOW DIAGRAMS, PIPING AND INSTRUMENTATION DIAGRAMS ( Second Revision ) 1 SCOPE
Section 09
Heating
This standard lays down symbols that are to be used while preparing process flow diagrams as well as piping and instrumentation diagrams in order to represent the major requirements of plant or units in the chemical industry.
Section
Furnaces
10
and cooling and boilers
Section 11
Process vessels
Section
Storage ~vessels/tanks
Section
Dryer
2 SYMBOLS
Section
Size reduction
2.1 The symbols indicated here represent only major items of plants. Two or more of the basic symbols may be combined to represent composite units.
Section 1
Separators
Section
Filters
2.2 Requirement of symbols following Sections:
has been covered in the
16
arrangements
Section 17
Centrifuges
Section
18
Stirrers
equipment
Section 0 I
General
Section 19
Mixers
Section 02
Process quantities
Section 20
Feeders
Section 03
Piping
Section 2 1
Conveyors
Section 04
Valves
Section 22
Transport
Section 05
Fittings
Section 23
Miscellaneous
Section 06
Instruments
Section 24
Service fluid codes
Section 07
Pumps
Section 25
Insulation/tracings
Section 08
Compressors
vehicle
types
IS 3232 : 1999 SECTION
01
GENERAL
DESCRIPTION
REMARKS
INSULATION OR TRACING FOR EQUIPMENT AND LINES ARE GENERALLY NOT St_IOWN SYMBOLICALLY IN PFD’S AND
2)
SECTION 0201
LIQU!D
GAS
INSULATION OF AN EQUIPMENT
02
PROCESS
I
I
I
PLACE NUMERICAL QUANTITIES SPECIFiED THE SYMBOL I WITHIN
FLOW
I PRESSURE AND TEMPERATURE
0203
QUANTITIES
FLOW
I
0202
IN P&IDS, THE LETTERS INDICATING THE TYPE OF INSULATION OR TRACING ARE PLACED ON TOP OF THE LINE
I
2
IS 3232 : 1999
SECTION
03
PIPING
DESCRIPTION
INFLOW
LINE
OUTFLOW
LINE
CONNECTING
CROSS
REMARKS
VENDOR
NAME
IDENTIFY
BY
NAME
LINE
OF FLOW
NOT
SLOPE OF A PROCESS LINE
BURIED
BY
LtNE
OVER
DIRECTION PROCESS
IDENTIFY
LIMITS.
DEGREES ARE TO BE SHOWN SEPARATELY
LINE
LIMIT
LINE
--Iv__--I-_Iv
ORM OF HEATING BY BE INDICATED
CHANGE OF SPECIFICATION
PROCESS
PIPE
LINE
TO INITIAL
IS 3232 : 1999 SECTION
SY M. NO.
DESCRIPTION
C140 1
GATE
C ,402
GLOBE
VALVE
C1403
CHECK
VALVE
04
VALVE
REMARKS
SYMBOL
VALVE
-z-
c1404
ANGLE
VALVE “p
(1405
DIAPHRAGM
SAFETY (1406
(1407
VALVE
VALVE
(PRESSURE VALVE)
BALL
RELIEF 4
VALVE S
(3408
SOLENOID
VALVE
-c% TWO
WAY S
+ THREE 0409
FLOAT
WAY
VALVE -&
0410
BUTTERFLY
0411
REGULATING VALVE
0412
FOOT WITH
VALVE
GLOBE
VALVE STRAINER @
0413
PLUG
VALVE
0414
CONTROL
-I&
VALVE
(Conti?lued)
IS 3232 : 1999
SECTION
04
VALVE
SYM. ND
DESCRIPTION
0415
PI STON OPERATED H’ YDRAULIC VALVE CCDNTROL
-I%
_ECTRICALLY PERATED 0 DNTROL VALVE
z
0416
SYMBOL
0417
PI INCH
0418
S PRING V ALVE
0419
C ONTROL VALVE H flTH HAND WHEEL
0420
P CV
DOWN
0421
P‘CV
UP
0422
I-IAND L‘ALVE
0423
F‘LUNGER CIPERATED
REMARKS
I
VALVE
LOADED
-
STREAM
STREAM
OPERATED
VALVE
-E$
-I 0424
F‘ILOT \ IALVE
-
OPERATED $k -4
0425
1$ -
WAY
VALVE -+-
0426
I‘JEEDLE
0427
IPOSITIVE
0428
ADJUSTABLE
VALVE
CHOKE
CHOKE
5
J
IS 3232 : 1999 SECTION
YM.
05
SYMBOL
DESCRIPTION
NO.
0501
EXPANSION
0502
HOSE
0503
FLEXIBLE
0504
SPECTACLE
FITTINGS
JOINT
CONNECTOR
HOSE
BLIND
P
At-
0505
LINE
BLIND
t
-It-
0506
REDUCER/EXPANDER
0507
BLIND
FLANGE
0508
DRAIN
FUNNEL
0509
THREADED
0510
ORIFICE
0511
REMARKS
+I
Y
CAP
--IIt-
VENTURI
METER ch-
0512
0513
STEAM
VENT
TRAP
WITH
-+q-
GOOSE
NECK r
(Conlinued) 6
IS 3232 : 1999 SECTION
r
FITTINGS
REMARKS
SYMBOL
DESCRIPTION
GHT
05
GLASS
0515
NION
3516
OUPLING
517
rDAPTOR
518
‘LOW
.-III-E
-
ELEMENT
519
rURBlNE
METER
1520
‘OS.
1521
ROTAM ETER .
1522
SONIC
1523
MAGNETIC
1524
PITOT
0525
DRAIN
PLUGGED
0526
DRAIN
FLANGED
DISP.
METER
-m
METER
M
METER
TUBE
3-
I
( Continued) 7
SECTION
iYk.4. NO.
DESCRIPTION
0527
STRAIGHTENING VANES
0528
ANALYSER
05
SYMBOL
A
-&
--ml--
0529
FILTER
0530
FILTER
lzl
0531
‘,,,,,‘,:‘,’
kc+
0532
0533
0534
Y I-
FITTINGS
TYPE 9
STRAINER
TEMPORARY STRAINER
BASKET
TS
I)
cl
STRAINER e
0535
FLAME
0536
CONE TYPE STRAINER
0537
SAMPLE
0538
PIPE
ARRESTER
lxl
POINT
CAP
pa
0S
WELDED
8
REMARKS
IS 3232 : 1999
SECTION fM. NO.
06
INSTRUMENTATION
DESCRIPTION
SYMBOL
0601
INSTRUMENT SIGNAL
AIR
-
0602
lNSTRUMENT SIGNAL
ELECTRIC
._
0603
INSTRUMENT LINES
SUPPLY
0604
INSTRUMENT CAPPILLARY
0605
1606
1607
1608
TUBING
HYDRAULIC
LINES
_,
---
vvvv AAI\I\
-L-L-L-
SOFTWARE CONNECTIONS
h ”
INSTRUMENTS LOCALLY MOUNTED
0
INSTRUMENT MOUNTED ON MAIN PANEL 8
1609
INSTRUMENT ON LOCAL
MOUNTED PANEL
e
1610
MOUNTED TRANSMITTER
LOCALLY
0
3611
MOUNTED TRANSMITTER
PANEL
8
0612
COMPUTER
0613
COMPUTER PANEL
0
LOCAL e
0614
DCS
/
DIDC
0615
GAS
FILTER
g%
lzl
9
SYMBOL REMARKS
IS3232:199!I SECTION
06
PANEL
RUNNING
TE
LIGHT
TELEMETRIC
INLET SIZE ; INCHES ORIFICE CODE LETTER OUTLET SIZE INCHES SAFETY VALVE SET PRESSURE kg/cm* g
RUPTURE
DIAPHRAGM
BREATHER
DISK
SEAL
VALVE
PROGRAMMABLE
CONTROL
ON
SYMBOL REMARKS
DESCRIPTION
REAR
iNSTRUMENTATlON
LOGIC
LOCAL
IS 3232 : 1999
SECTION 06 INSTRUMENT LEGEND (Refer Table 1 for definition of identification letters) P
PRESSURElNSTRUMENTS
PV
PRESSURE CONTROL VALVE
T
TEMPERATURE
TV
TEMPERATURE
L
LEVEL INSTRUMENTS
LV
LEVEL CONTROL VALVE
IL
INTERFACE LEVEL INSTRUMENTS
ILV
INTERFACE LEVEL CONTROL VALVE
F
FLOW INSTRUMENTS
FV
FLOW CONTROL VALVE
A
ANALYSER INSTRUMENTS
AV
GAS ACTUATED VALVE
PCV
SELF ACTUATED PRESSURE CONTROL VALVE
I/P
CURRENT TOPNEUMATIC TRANSDUCER
TW
THERMOWELL
P/I
TE
TEMPERATURE
PNEUMATIC TO CURRENT TRANSDUCER
PB
PUSHBUTTON
I/E
CURRENT TO VOLTS TRANSDUCER
sov
SOLENOID OPERATED VALVE
E/I
VOLTS TO CURRENT TRANSDUCER
TJI
MULTIPOINT INDICATOR
E/P
VOLTS TO PNEUMATIC TRANSDUCER
DPG
DlFFERENTlAL
PRESSURE
P/E
PNEUMATIC TO VOLTS TRANSDUCER
DJC
DIFFERENTIAL CONTROLLER
INDICATING
SDV
SHUT DOWN-VALVE
MOV
MOTOR OPERATED VALVE
DIFFERENTlAL CONTROLLER
RECORDING
XL
RUNNING LIGHTS
XI
RUNNING INDlCATIONS
DRC
.
INSTRUMENTS
ELEMENT
GAUGE
CONTROL VALVE
I
INDICATOR
TT
TEMPERATURE
R
RECORDER
SC
SAMPLE COOLER
IC
INDICATING CONTROLLER
UC
UTILITY CONNECTION
RC
RECORDING CONTROLLER
FG
FLOW GLASS
Y
FUNCTION (MODIFIER)
PSV
PRESSURE
Q
INTEGRATOR (SUMMATOR)
TSV
THERMAL SAFETY VALVE
AL
ALARM LOW
RD
RUPTURE DISK
AH
ALARM HIGH
HIC
HAND INDICATING CONTROLLER
ALL
ALARM LOW LOW
HCV
HAND CONTROL VALVE
AHH
ALARM HIGH HIGH
ss
SELECTION
SL
SWITCH LOW
FO
CONTROL VALVE FAIL OPEN
SH
SWITCH HIGH
FC
CONTROL VALVE FAIL CLOSE
SLL
SWITCH LOW LOW
FL
CONTROL VALVE FALL LOCK
SHH
SWITCH HIGH HIGH
TSO
TIGHT SHUT OFF
PI
PRESSURE
PVRV
Tl
TEMPERATURE
BREATHER VALVE (PRESSURE VACUUM RELIEF VALVE)
LI
LEVEL INDICATOR
AF
FLAME ARRESTOR
ILG
I-NTERFACE LEVEL GAUGE
EX
EXCESS FLOW CHECK VALVE
FE
FLOW ELEMENT
RTU
REMOTE TERMINAL UNIT
AE
ANALYSER ELEMENT
IJ
INSULATION JOINT
PT
PRESSURE TRANSMITTER
LSS
LOW SIGNAL SELECTOR
LT
LEVEL TRANSMITTER
MSS
MANUAL SIGNAL SELECTOR
FT
FLOW TRANSMITTER
LO
LOCK OPEN
AT
ANALYSERTRANSMITTER
LC
LOCK CLOSE
INTERFACE LEVEL TRANSMITTER
ZSH
POSITION SWITCH HIGH (VALVE OPEN)
lLT
INDICATOR INDICATOR
11
TRANSMITTER
SAFETY VALVE
SWITCH
IS 3232 : 1999 ZHH
POSlTION
HIGH HIGH (VALVE OPEN)
FB
FULL BORE
ZAH
POSITION OPEN)
ALARM HIGH (VALVE
NB
NORMAL
AS
AUTOMATIC
ZSL
POSITION CLOSE)
SWITCH LOW (VALVE
DPT
DIFFERENTIAL TRANSMITTER
ZLL
POSITION VALVE)
LOW LOW (FULL CLOSED
FO
RESTRICTION
C
CONTROLLER
ZAL
POSITlON CLOSED)
ALARM LOW (VALVE
uv
ON-OF VALVE
Table 1 Identification
BORE SAMPLER PRESSURE ORIFICE
Letters
Multifunction
Multifunction
U
Multivariable
V
Vibration, Mechanical Analysis
W
Weight, Force
X
Unclassified
X Axis
Y
Event, State or Presence
Y Axis
Relay, Compute, Convert
Z
Position, Dimension
Z Axis
Driver, Actuator Unclassified Final Control Element
Multifunction
Valve, Damper, Louver Well Unclassified
12
Unclassified
Unclassified
IS 3232 : 1999
SECTION YM.
DESCRIPTION
NO.
0701
CENTRIFUGAL
07
PUMPS
SYMBOL
PUMPS
REMARKS
, -$&BOL GEAR
PLUNGER POSITIVE DISPLACEMENT
0702
PUMP-w
PUMP
PUMP RECIPROCATING DUPLEX
0703
PROPORTIONING
0704
HAND DRUM
PUMP
PUMP
PUMP
WITH
PROCESS
0705
Fv”:::%
SERVICE)
0706
BLOWING
EGG
\
FLUID
PUMP
Is3232:199!I
SECTION
08
CENTRIFUGAL COMPRESSOR
0801
REMARKS
SYMBOL
DESCRIPTION
9 ‘M. NO.
COMPRESSORS
M 0
POSITIVE DISPLACEMENT COMPRESSOR
0802
h
T
RECIPROCATING COMPRESSOR
0803
?I%
0804
EJECTOR COMPRESSOR
0805
FAN 7
M
TURBINE
0806
T
Q+
SECTION
S YM.
0901
NO.
09
HEATING
DESCRIPTION
IMMERSION
COIL
OR
COOLING SYMBOL
ARRANGEMENTS REMARKS
EXAMPLES-
IS 3232
SECTION 04.
HEATING
OR
COOLING
DESCRIPTION
NO.~
0902
09
SYMBOL
ARRANGEMENTS REMARKS
EXCHANGER (IN
PFD) a
0903
HEAT
EXCHANGER -Q
0904
0905
0906
EXCHANGER _
,@
Y
u
EXCHANGER
KETTLE
REBOILER Q c
0907
KETTLE
REBOILER
KETTLE 2
0909
-
REBOILER BUNDLE
TUBULAR
:-
EXAMPLE
:-
COIL
0
0908
0910
EXAMPLE
JACKET
15
: 1999
Is 3232 : 1999
SECTION fM.
0911
09
HEATING
,OR
COOLING
DESCRIPTION
NO.
NATURAL COOLING
ARRANGEMENTS
SYMBOL
REMARKS
DRAUGHT TOWER
fi
0912
INDUCED COOLING
DRAUGHT TOWER
c&l
0913
AIR
BLOWN
COOLER
USED
FOR
PFD
USED
FOR
P&l
)001 -m 0914
TRICKLE
COOLER
C 0915
PLATE HEAT
TYPE EXCHANGER
0916
AIR COOLER WITH FAN AND MOTOR
z,
M
0917
CONTACT
CONDENSER
0918
DESUPER
HEATER
16
(Continued)
IS 3232 : 1999
SECTION S YM. NO.
09
HEATING
OR
COOLING
DESCRIPTION
ARRANGEMENTS REMARKS
SYMBOL
0919
ONE CELL FIRED HEATER/FURNACE
0920
TWO CELL FIRED HEATER/FURNACE a
SECTION
10
FURNACES
AND
BOILERS
7
S'YM. NO.
SYMBOL
DESCRIPTION
1001
SOLID FUEL FURNACE
1002
OIL. GAS OR PULVERIZD FUEL FURNACE
1003
ELECTRIC
1004
FiRED
1005
WASTE BOILER
FURNACE
BOILER
HEAT -
17
REMARKS
IS 3232 : 1999
SECTION SYM.
NO. 1
DESCRIPTION
1101
HORIZONTAL VESSEL
1102
VERTICAL VESSEL
11
PROCESS SYMBOL
I
VESSELS REMARKS
I
VESSEL 1103
JACKETED
0 B
1104
PACKED VESSEL
1105
EVAPORATOR
L
CRYSTALLIZER
1107
AUTOCLAVE
:-
CATALYTIC
REACTOR
ABSORBER,
Q
1106
EXAMPLES
._
0C
0
,.
4
ETC.
IS 3232 : 1999
SECTION IM.
NO.
1108
,08A
11
PROCESS
DESCRIPTION CONSTRUCTION CONTAINERS, TOWERS AND
VESSELS REMARKS
SYMBOL
INSIDE COLUMNS REACTORS
PLATES/TRAYS (FOR MASS
TRANSFER)
EXAMPLE I
1088
FLUIDIZED
BED
1109
MULTI BED COLUMN
1110
VESSEL
1111
DEAERATOR
t112
FLA’NGED
PACKED
WITH
:-
TRAY SHOULD BE NUMBERED FROM THE BOTTOM ATLEAST 1HE FIRST AND LAST SHOULI BE SHOWN. INTERMEDIATE TRAY SHOJJLD BE INCLUDED k NUMBERED WHERE THEY ARE SIGNIFICANTS.
BOOT
VESSEL
I
IS 3232:1999 SECTION StYM.
1113
NO.~
11
PROCESS
DESCRIPTION
DOUBLE VESSEL
SYMBOL
FLANGED II
1114
CONICAL VESSEL
BOTTOM
0
1115
VESSEL ONE -
WITH SUMP
1116
VESSEL TWO -
WITH SUMPS
L 20
VESSELS REMARKS
IS 3232 : 1999
SECTION ;Yt.i.
NO.
12
STORAGE
VESSELS
DESCRIPTION
1201
‘IXED ANK
1202
‘LOATING ‘ANK
1203
‘LOATING CUM ‘IXED ROOF TANK
1204
GAS WET
HOLDER, SEAL
1205
GAS DRY
HOLDER, SEAL
1206
PRESSURE STORAGE (SPHERE OR SPHEROID; HORTON SPHERE
/
TANKS
SYMBOL
ROOF
ROOF
m $4
21
REMARKS
IS 3232 : 1999
SECTION s YM.
NO.
DESCRIPTION
1301
BATCH DRIER
TRAY
1302
SPRAY
DRIER
1303
CONTINUOUS
1304
ROTARY DRIER OR KILN
13 SYMBOL
DRIER
22
DRYERS REMARKS
IS3232:f989
SECTION WM.
L
NO. i
14
DESCRIPTION
1401
SIZE REDUCING EQUIPMENT (GENERAL SYMBOL)
1402
BREAKER,
1403
BREAKER HAMMER MILL IMPACT MILL
1404
JAW
1404A
ROLLER
1405
GRINDER
1406
BALL
I
GYRATORY
CRUSHER
CRUSHER
OR
TUBE
MILL
SIZE
REDUCTION
* V
SYMBOL
EQUIPMENTS 1
REMARKS EXAMPLE
:-
PULVERIZER
Is’ 3232 : 1999 SECTION YM.
NO.
DESCRIPTION
50 1
‘CLONE OR ‘DROCYCLONE
502
_ECTROSTATIC I.PARATOR :LECTRICAL JRIFICATION F GAS)
I503
EPERATORS FOR IQUIDS. DECANTOR
1504
15
SEPARATORS SYMBOL
v+ v
‘HICKENER
-*-aSCREEN,
1505
REMARKS
SCREEN
VIBRATORY
24
SCREEN,
ROTARY
IS 3232 : 1999
SECTION SYM.
NO.
FILTER
1602
SUCTION
1603
PRESSURE
1604
FILTERS
SYMBOL
DESCRIPTION
1601
16
REMARKS
PRESS
FILTER
FILTER
GRAVITY FILTER (OPEN SETTLING
1605
OPEN ROTARY VACUUM FILTER
1606
CLOSED VACUUM
--___.._ -__-_-_______ --_____ TANK)
ROTARY FILTER
BASKET
1607
BAG
FILTER
u
FILTER
IS3232:1999 SECTION
CENTRIFUGES (GENERAL SYMBOL)
BASKET BATCH
1703
17
CENTRIFUGES
’
CENTRIFUGE OR CONTINOUS
PLATE
CENTRIFUGE
SECTION
18
STIRRERS EXAMPLE:-
1801
GENERAL
SYMBOL
Jd
8
EXAMPLE:-
1802
SPARGER
26
IS 3232 : 1999 SECTION
RIBBON
DOUBLE
1904
EJECTOR
1905
ROTARY
19
MIXERS
BLENDER
CONE
MIXER
MIXER
2 0
I
t 1906
ON
-
LINE
MIXER
--cw
I)
M
1907
MIXER
L
1908
SACONY
MIXER
21
IS 3232 : 1999 SECTION YM. NO.
20
DESCRIPTION
FEEDERS REMARKS
SYMBOL I
2001
GENERAL
SYMBOL
6
1
2002
VIBRATOR
FEEDER
ti I 2003
WEIGH
FEEDER
-a
2004
I
ROTARY TABLE FEEDER, REVOLVING PLATE FEEDER
I
+
I 2005
SCRAPER
FEEDER a
2006
SCREW
FEEDER +!iikvF
2007
ROTARY
FEEDER
I
IS 3232 : 1999
SECTION 21 cotw~o~s W.
DESCRIPTION
NO.
2101
B ELT
2102
s CRAPER
2103
V‘IBRATING -C :ONVEYOR
SYMBOL
CONVEYOR
CONVEYOR
2104
c_iCREW
2105
EtUCKET
CONVEYOR
2106
F?OLLER
CONVEYOR
2107
(IVERHEAD (ZONVEYOR \ NITH HOOKS
21078
( IVERHEAD CONVEYOR (IR ROPEWAY WITH I3UCKETS OR CARRIER
2108A
IFIXEO ‘-1 WITH
CONVEYOR
HOlST HOOK
2108E I
TRAVELLING WITH HOOK
HOIST
2108(
. I
TRAVELLING ,WITH GRAB
HOIST
2108
D
AIR
I --
FLOATS
&&my
29
REMARKS
IS 3232 : 1999
IYM. NO.1
SECTION DESCRIPTION
L
!201
SHIP
1
!202
WAGON, TRUCK
c
22
I
TRANSPORT
VEHICLES
SYMBOL
I
REMARKS
LORRY~,
00
-
2203
TANKER 00
2204
OPEN
‘I
TRAILER
’ 00
-
BOTTOM 2205
WAGON
HOPPER WITH
1
SECTION
2301
SILENCER
2302
LAUNCHER
2303
DIESEL
W 23
MISCELLANEOUS
bl
RECEIVER
-
GENERATOR
0
IS 3232 : 1999
SECTION M. NO.
2304
DESCRIPTION
23
MISCELLANEOUS SYMBOL
I
I
TURBINE GENERATOR
2305 2305
REMARKS
HOSE
REEL
2305
2306~
WELL HEAD WITH ONE B-ORE (SINGLE COMPLETION)
23068
WELL HEAD WITH TWO BORE (DUAL COMPLETION)
A
B
Is 3232 : 1999 SECTION
23
MISCELLANEOUS 7
SYM. NO.
DESCRIPTION
2307
SUMP
2308A
FLARE
23088
FLARE
SYMBOL
I
I
REMARKS
CAISSON
4
STACK
H
2309
CHIMNEY
2310
SCRAPPER
1;1
TEE &
2311
ATMOSPHERIC
VENT
4
32
( Continued )
IS 3232
SECTION
2312
23
: 1999
MISCELLANEOUS
CYLINDER
CYLINDER
2313
GRADUATED
2314
CRANE
2315A
ELECTROLYTIC CELL WITHOUT DIAPHRAGM
0
+-
23158
ELECTROLYTIC CELL WITH DIAPHRAGM
2316
TURBINE
2317
MOTOR
DRIVE
DRIVE
qii+
0
T
0
M
33
(
Continued )
Is 3232 : 1999 SECTtON SYM.
NO.1
DESCRIPTION
SWIVEL
CBD
DRAIN
-
SAMPLE
SYMBOL
COOLER
I
23
MISCELLANEOUS SYMBOL
I
REMARKS
IS 3232 : 1999
SECTION 24 SERVICE FLUID CODES P
PROCESS
HM
HEATING MEDIUM
WCS
COOLING WATER SUPPLY
HMS
HEATING MEDIUM SUPPLY
WCR
COOLING WATER RETURN
HMR
HEATING MEDIUM RETURN
WD
DRINKING WATER
EG
50% EG SOLUTION
ws
SERVICE WATER
CHWS
CHILLED WATER SUPPLY
WF
FIRE WATER
CHWR CHILLED WATER RETURN
WR
RAW WATER
WDM
DEMlNERALISED WATER
WP
PROCESS WATER
SH
SP STEAM
WT
TREATED WATER
SM
MP STEAM
Al
INSTRUMENT AIR
SL
LP STEAM
AP
PLANT AIR
CH
CONDENSATE HP
AB
BREATHING
CM
CONDENSATE Ml’
BD
BLOW DOWN
CL
CONDENSATE LP
FL
FLARE
N
NITROGEN
FO
FUEL OIL
BR
BRINE
FG
FUEL GAS
cs
CAUSTIC SEWER
Gl
INSTRUMENT GAS
IG
INERT GAS
NA
CAUSTIC
ows
OILY WATER SEWER
RE
REFRIGERANT ETHANE
ss
STORM SEWER
RA
REFRIGERANT AMONIA
CBD
CLOSED BLOW DOWN
RP
REFRIGERANT PROPANE
D
DRAIN
AC
ACID LINES
UC
UTILITY CONNECTION
AIR
35
IS 3232 : 1999
SECTION 25 INSULATION/TRACING
TYPE
IH
HOT INSULATION
IE
ELECTRIC~TRACED
1C
COLD INSULATION
IA
ACCOUSTK
IS
SAFETY INSULATION
IF
THERMAL FLUID TRACING
IT
STEAM TRACED
36
INSULATION
Bureau of Indian Standards BIS is a statutory institution established under the Bureau of Indian Standards Act, 1986 to promote harmonious development of the activities of standardization, marking and quality certification of goods and attending to connected matters in the country. Copyright BIS has the copyright of all its publications. No part of these publications may be reproduced in any form without the prior permission in writing of BIS. This does not preclude the free use, in the course of implementing the standard, of necessary details, such as symbols and-sizes, type or grade designations. Enquiries relating to copyright be addressed to the Director (Publications), BIS. Review of Indian Standards Amendments are issued to standards as the need arises on the basis of comments. Standards are also reviewed periodically; a standard along with amendments is reaffirmed when such review indicates that no changes are needed; if the review indicates that changes are needed, it is taken up for revision. Users of Indian Standards should ascertain that they are in possession of the latest amendments or edition by referring to the latest issue of ‘BIS Handbook’ and ‘Standards: Monthly Additions’. This Indian Standard has been developed from Dot : No. MED 17 (0199).
Amendments Issued Since Publication Amend No.
Text Affected
Date of Issue
BUREAU OF INDIAN STANDARDS Headquarters : Manak Bhavan, 9 Bahadur Shah Zafar Marg, New Delhi 110 002 Telephones : 323 01 31,323 33 75,323 94 02
Telegrams : Manaksanstha (Common to all offices)
Regional Offices : Central
Telephone
: Manak Bhavan, 9 Bahadur Shah Zafar Marg
t 323 76 38 41 13
NEW DELHI 110 002 Eastern
: l/l4 C. I. T. Scheme VII M, V. I. P Road, Kankurgachi
337 84 99,337 85 61 337 86 26,337 9120
CALCUTTA 700 054 Northern
: SC0 335-336, Sector 34-A, CHANDIGARH 160 022 { 60 38 20 43 25
Southern Western
‘: C. I. T. Campus, IV Cross Road, CHENNAI 600 113
[ 235 02 16,235 04 42 23 15
1 235 15 19,235
: Manakalaya, E9 MIDC, Marol, Andheri (East)
{ 832 92 95,832 78 58 832 78 91,832 78 92
MUMBAI 400 093 Branches
: AHMADABAD.
BANGALORE. BHOPAL. BHUBANESHWAR. COIMBATORE. FARIDABAD. GHAZIABAD. GUWAHATI. HYDERABAD. JAIPUR. KANPUR. LUCKNOW. NAGPUR. PATNA. PUNE. RAJKOT. THIRUVANANTHAPURAM. i&d
a : Pmbha 0Vs.l Pmss. Nm Ddhi-2