Project General Notes
BUTTERFLY VALVE
DOMESTIC HOT WATER RETURN PIPE
GLOBE VALVE
NATURAL GAS PIPE
GATE VALVE
SANITARY VENT PIPE SANITARY PIPE
DUCT SMOKE DETECTOR RELAY COIL THERMOSTAT TEMPERATURE SENSOR KEYED NOTE DESIGNATION
ABBREVIATIONS AC
AIR CONDITIONER
A.F.F.
ABOVE FINISHED FLOOR
DRAIN VALVE
BD
BALANCING DAMPER
MANUAL AIR VENT.
BFP
BACK FLOW PREVENTER
GRISWOLD FLOW CONTROL VALVE
CFM
CUBIC FEET PER MIN
CO
CLEANOUT
COTG
CLEANOUT TO GRADE
CW
COLD WATER
TRIPLE DUTY VALVE
DCO
DOUBLE CLEANOUT
CHECK VALVE
DF
DRINKING FOUNTAIN
GAUGE COCK
D-1
DIFFUSER TYPE
ESP
EXT STATIC PRESS
EX
EXHAUST GRILL
EXT, EXIST
EXISTING
GAS PRESSURE REGULATOR
FCO
FLOOR CLEANOUT
GAS SOLENOID VALVE W/HI-LO FIRE
FD
FLOOR DRAIN
FS
FLOOR SINK
FPH
FREEZE PROOF HYDRANT
FHB
FREEZE PROOF HOSE BIBB
F-1
FURNACE TYPE
TWO-WAY CONTROL VALVE PNEUMATIC BYPASS VALVE
BALANCING VALVE GAS COCK
EXHAUST FAN SUPPLY DIFFUSER
T
RELIEF VALVE
RETURN GRILL
PETE'S PLUG
ELECTRIC THERMOSTAT
THERMOMETER W/WELL
UNION
PADDLE TYPE FLOW SWITCH
GPM
GALLONS PER MIN
BALANCING OR PLUG COCK
DIFFERENTIAL PRESSURE FLOW SWITCH
HB
HOSE BIBB
RISE IN PIPING
DIFFERENTIAL PRESSURE SENSOR
HW
HOT WATER
DROP IN PIPING
PRESSURE GAUGE
LAV
LAVATORY
NO.
NUMBER
OSA
OUTSIDE AIR
FLEXIBLE CONNECTOR
PSI
POUNDS PER SQ IN
STRAINER
RG
RETURN GRILL
MALE HOSE CONNECTOR
RM
ROOM
TYP
TYPICAL
UH
UNIT HEATER
UNO
UNLESS NOTED OTHERWISE
PIPE GUIDE
UR
URINAL
PIPE EXPANSION LOOP
VTR
VENT THRU ROOF
EXPANSION JOINT
WCO
WALL CLEANOUT
WC
WATER CLOSET
WH
WATER HEATER
VALVE IN RISE OR DROP D-X 000/000 CFM
SENSOR WELL
DIFFUSER SYMBOL COOLING/HEATING AIRFLOW
PIPING REDUCER PIPE ANCHOR
UNION FLOW ARROW TEE CONNECTION
C.
CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE LAY OUT AND INSTALLATION OF THE PLUMBING SYSTEMS INCLUDING ALL COORDINATION WITH NEW AND EXISTING SERVICES MECHANICAL EQUIPMENT, DUCTWORK AND ELECTRICAL EQUIPMENT.
T.
MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.
U.
CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION OF OUTAGES WITH BOTH THE OWNER AND UTILITY COMPANIES, FOR UTILITY CONNECTIONS.
SANITARY VENT TERMINATIONS SHALL BE A MINIMUM DISTANCE OF 10' HORIZONTALLY OR 3' ABOVE ANY BUILDING OPENING OR AIR INTAKE.
V.
DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA STANDARDS, AND UMC STANDARDS.
D.
CONTRACTOR SHALL VERIFY INVERTS BEFORE ROUTING ANY PIPING.
E.
WASTE PIPING SHALL BE PVC OR CAST IRON. VENT PIPING MAY BE PVC PIPE OR CAST IRON ABOVE AND BELOW FLOOR, PER UPC LIMITATIONS, AND CITY CODES.
F.
G.
H.
PROVIDE GAS COCKS AND FLEXIBLE CONNECTIONS AT EACH GAS OUTLET OR APPLIANCE.
W. CONTRACTOR SHALL COORDINATE WITH ELECTRICAL AND ARCHITECTURAL TO DETERMINE FINAL DIFFUSERS LOCATIONS. X.
ALL WATER PIPING SHALL BE TYPE M COPPER ABOVE FLOOR AND TYPE L SOFT COPPER BELOW FLOOR OR CROSS LINKED POLYETHYLENE (AQUAPEX) TUBING MEETING ASTM F87-99A ABOVE AND BELOW FLOOR.
Y.
INSULATE SUPPLY DUCTWORK PER TABLE THIS SHEET. WITH FOIL FACED EXTERNAL DUCT WRAP. PROVIDE ALUMINUM ROLL JACKETING MEETING ASTM B-206, H-14 TEMPER, .016" THICKNESS FOR EXTERNAL DUCT. DUCT DIMENSIONS ARE CLEAR INSIDE.
NATURAL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL ABOVE GRADE AND SHALL BE EITHER PROTECTED SCH 40 BLACK STEEL WRAPPED OR SDR-11 POLYETHENE BELOW GRADE.
Z.
SEE EQUIPMENT SCHEDULE FOR EQUIPMENT TYPES AND SIZES. MINIMUM BURY DEPTH FOR WATER IS 4' AND 2' FOR GAS.
BB. INSTALL SPLITTERS AT BRANCH CONNECTIONS.
I.
ROUTE PIPING AS NEARLY AS POSSIBLE TO ROUTES INDICATED ON PLANS. CONTRACTOR IS FREE TO MAKE MINOR CHANGES IN ROUTING TO ACCOMMODATE CONDITIONS.
J.
CONTRACTOR RESPONSIBLE FOR ALL REQUIRED TRANSITIONS, OFFSETS MINOR RELOCATIONS, AND ALL ASSOCIATED FITTINGS
K.
CONTRACTOR SHALL INSTALL A COMPLETE OPERATING SYSTEM, INCLUDING REFRIGERANT PIPING, EQUIPMENT, CONTROLS, AND CONDENSATE DRAIN TO APPROVED INDIRECT WASTE.
CC. CONTRACTOR SHALL HAVE INDEPENDENT TEST AND BALANCE CONTRACTOR BALANCE AIR FLOWS PER DRAWINGS AND ADJUST ALL TEMPERATURE AND CONTROL DEVICES. MECHANICAL CONTRACTOR SHALL TEST RUN SYSTEM FOR A PERIOD OF 8 HRS., VERIFIED BY GENERAL CONTRACTOR, BEFORE GIVING NOTICE OF COMPLETION OF WORK. DD. CONTRACTOR SHALL INSTALL A PRESSURE REGULATOR AT THE INCOMING WATER SERVICE IF SITE WATER PRESSURE EXCEEDS 80 P.S.I. REGULATOR SHALL MATCH LINE SIZE. FF. CONTRACTOR SHALL PROVIDE ACCESS PANELS OF APPROPRIATE SIZE FOR ALL INACCESSIBLE REMOTE EQUIPMENT.
ANY LINES ENCOUNTERED WHICH MAY INTERFERE WITH NEW CONSTRUCTION SHALL BE RELOCATED IF ACTIVE AND REMOVED IF INACTIVE.
M.
ALL WATER PIPING LOCATED IN EXTERIOR WALLS OF THE BUILDING SHALL BE INSULATED WITH 1/2" INSULATION AND BE LOCATED ON BUILDING INTERIOR SIDE OF INSULATION. ALL HW/CW, P-TRAPS AT HANDICAPPED LAVATORIES SHALL BE INSULATED.
O.
CONTRACTOR SHALL PROVIDE 12" RISERS, CAPPED AT EACH FIXTURE FOR SHOCK ABSORPTION OR A SHOCK ABSORBER UNIT FOR THE SYSTEM.
P.
PROVIDE WALL CLEAN OUTS AND SHUT OFF VALVES AT ALL SINKS AND WALL MOUNTED URINALS.
Q.
PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS OF WALLS AND FLOORS.
INSTALL TURNING VANES IN RECTANGULAR ELBOWS.
AA. ALL REGISTERS AND DIFFUSERS SHALL HAVE DAMPERS OR EXTRACTORS FOR AIR BALANCING.
L.
N.
GG. CONTRACTOR SHALL NOT MODIFY ANY STRUCTURAL MEMBERS SUCH AS BEAMS, COLUMNS, TRUSSES, ETC. HH. SEE ARCHITECTURAL DRAWINGS FOR ROOF DRAINS. II.
ALL PIPING AND DUCTWORK THAT PENETRATES A FIRE RATED WALL SHALL BE SEALED WITH APPROVED FIRE STOPPING TO RESTORE THE FIRE RATING AND MAKE WEATHER TIGHT AS REQUIRED.
NEW TO EXISTING CONNECTION
MINIMUM DUCT INSULATION
MINIMUM PIPE INSULATION
SEISMIC RESTRAINT FOR WATER HEATERS.
BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTION 803.2.8
BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTIONS 504.4 AND 504.5.
BASED ON: UNIFORM MECHANICAL CODE SECTION 508.2.
DUCT AND PLENUM INSULATION AND SEALING: ALL SUPPLY AND RETURN DUCTS AND PLENUMS SHALL BE INSULATED WITH A MINIMUN OF R-6 INSULATION WHEN LOCATED IN UNCONDITIONED SPACES AND A MINIMUM OF R-8 INSULATION WHEN LOCATED OUTSIDE THE BUILDING. WHEN LOCATED WITHIN A BUILDING ENVELOPE ASSEMBLY, THE DUCT OR PLENUM SHALL BE SEPARATED FROM THE BUILDING EXTERIOR OR UNCONDITIONED OR EXEMPT SPACES BY A MINIMUM OF R-8 INSULATION.
FOR AUTOMATIC-CIRCULATING HOT WATER SYSTEMS, PIPING SHALL BE INSULATED WITH 1" OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X°F. THE FIRST 8' OF PIPING IN NONCIRCULATING SYSTEMS SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS SHALL BE INSULATED WITH 0.5" OF MATERIAL HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X°F.
IN SEISMIC DESIGN CATEGORIES C,D,E, AND F, WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE MOTHION. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A DISTANCE OF NOT LESS THAN 4" SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING.
EXCEPTIONS: 1. WHEN LOCATED WITHIN EQUIPMENT. 2. WHEN THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15°F (8°C).
MINIMUM PIPE INSULATION BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE, SECTION 803.2.8
Hopewell
DOMESTIC HOT WATER PIPE
B.
S.
FILE NAME:
BALL VALVE
DESCRIPTION
TEMPERATURE AND HOT WATER SYSTEM CONTROLS BASED ON: IECC 2009 CODE SECTIONS 504.3 AND 504.6 SERVICE WATER-HEATING EQUIPMENT SHALL BE PROVIDED WITH CONTROLS TO ALLOW A SET POINT OF 110° F FOR EQUIPMENT SERVING DWELLING UNITS AND 90° F FOR EQUIPMENT SERVING OTHER OCCUPANCIES. THE OUTLET TEMPERATURE OF LAVATORIES IN PUBLIC FACILITY REST ROOMS SHALL BE LIMITED TO 110° F. AUTOMATIC - CIRCULATING HOT WATER SYSTEM PUMPS OR HEAT TRACE SHALL BE ARRAINGED TO BE CONVENIENTLY TURNED OFF AUTOMATICALLY OR MANUALLY WHEN THE HOT WATER SYSTEM IS NOT IN OPERATION.
CJH TOC
DOMESTIC COLD WATER PIPE
SYMBOL
TGA
DESCRIPTION
PROVIDE SHUT-OFF VALVES AT PLUMBING RISES.
1752 HOPEWELL SANTA FE , NEW MEXICO
SYMBOL
R.
HOPEWELL STREET HOUSING
G
DESCRIPTION
ALL WORK SHALL BE COMPLETED IN FULL COMPLIANCE WITH THE 2009 UPC, 2009 UMC, 2009 IECC, NFPA AND ALL LOCAL CODES AND ORDINANCES.
6.17.13 DATE: REVISION:
SYMBOL
A.
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
(ALL SYMBOLS MAY NOT BE USED)
THOMAS GIFFORD ARCHITECT
MECHANICAL/PLUMBING SYMBOL LEGEND
MECHANICAL NOTES & LEGEND SHEET:
M-001
UP TO 2rd FLOOR, FLOOR SUPPLY.
D-3 250 CFM 6"Ø
14"X10" D-1
8"Ø
1
D-3 250 CFM
D-1 2
6"Ø
EX-1
3
14"X10"
D-1 40 CFM
RH-1 8"Ø
8"Ø 10"Ø D-3 250 CFM
6"Ø
2
D-3 250 CFM
D-2 125 CFM
2
3
FIRST FLOOR MECHANICAL PLAN HT-2
Scale: 1/4" = 1'0"
2
SECOND FLOOR MECHANICAL PLAN HT-2
Scale: 1/4" = 1'0"
0 2 4
8
16
CJH VNF
3.
TGA
10"Ø
2
DOWN TO 1st FLOOR CEILING SUPPLY.
1752 HOPEWELL SANTA FE , NEW MEXICO
8"Ø
2.
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
3
RECIRCULATE AIR FROM TOP OF STAIR DOWN TO FIRST FLOOR.
THOMAS GIFFORD ARCHITECT
6"Ø
D-2 125 CFM
1.
HOPEWELL STREET HOUSING
Keyed Notes
FC-2
1
FILE NAME:
6.17.13 DATE: REVISION:
HP-2
EX-1
Hopewell
General Notes
1/8" = 1'-0"
MECHANICAL FLOOR PLAN SHEET:
M-101
FILE NAME:
6.17.13 DATE: REVISION:
Hopewell
General Notes
Keyed Notes
Scale: 1/4" = 1'0"
1
SECOND FLOOR MECHANICAL PLAN HT-3
Scale: 1/4" = 1'0"
0 2 4 1/8" = 1'-0"
8
16
24
CJH VNF
1
FIRST FLOOR MECHANICAL PLAN HT-3
HP-2
1752 HOPEWELL SANTA FE , NEW MEXICO
EX-1
EX-1
TGA
FC-2
THOMAS GIFFORD ARCHITECT
RH-1
HOPEWELL STREET HOUSING
CONTRACTOR TO REUSE EXISTING DUCTWORK. SUPPLY AND RETURN AIR GRILLS SHALL BE REPLACED WITH NEW EQUIPMENT.
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
1.
MECHANICAL FLOOR PLAN SHEET:
M-102
FILE NAME:
6.17.13 DATE: REVISION:
Hopewell
General Notes
EX-1
Keyed Notes 1. EX-1
EX-1
1
MECHANICAL PLAN HM-3
Scale: 1/4" = 1'0"
2
MECHANICAL PLAN HM-4
CONTRACTOR TO REUSE EXISTING DUCTWORK. SUPPLY AND RETURN AIR GRILLS SHALL BE REPLACED WITH NEW EQUIPMENT.
Scale: 1/4" = 1'0"
0 2 4 1/8" = 1'-0"
8
16
24
CJH VNF
1
1752 HOPEWELL SANTA FE , NEW MEXICO
HP-2
FC-2
TGA
FC-2
HOPEWELL STREET HOUSING
RH-1
THOMAS GIFFORD ARCHITECT
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
HP-2
MECHANICAL FLOOR PLAN SHEET:
M-103
14"X10"
2
D-3 250 CFM
6"Ø
D-1
EX-1
D-1 8"Ø
1
6"Ø
3
EX-1
Keyed Notes
D-1 40 CFM D-3 250 CFM
2
14"X10" RH-1
8"Ø
2
RECIRCULATE AIR FROM TOP OF STAIR DOWN TO FIRST FLOOR.
2.
DOWN TO 1st FLOOR CEILING SUPPLY.
3.
UP TO 2rd FLOOR, FLOOR SUPPLY.
8"Ø
D-3 250 CFM
D-3 250 CFM
6"Ø
3
1
1.
D-2 125 CFM
2
FIRST FLOOR MECHANICAL PLAN HT-A
Scale: 1/4" = 1'0"
2
SECOND FLOOR MECHANICAL PLAN HT-A
Scale: 1/4" = 1'0"
Legend 0 2 4 1/8" = 1'-0"
8
16
24
FILE NAME:
CJH VNF
8"Ø
1752 HOPEWELL SANTA FE , NEW MEXICO
HP-3
TGA
6"Ø
HOPEWELL STREET HOUSING
D-2 125 CFM
3
THOMAS GIFFORD ARCHITECT
FC-3
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
6.17.13 DATE: REVISION:
Hopewell
General Notes
MECHANICAL FLOOR PLAN SHEET:
M-104
Keyed Notes
1
MECHANICALFLOOR PLAN
Scale: 1/4" = 1'0"
0 2 4 1/8" = 1'-0"
8
16
24
CJH VNF
D-4 400 CFM
1752 HOPEWELL SANTA FE , NEW MEXICO
EX-1
TGA
EBB-1
THOMAS GIFFORD ARCHITECT
FC-1 RG-2 1
MOUNT FAN COIL ON GALVANIZED METAL PLATFORM. PROVIDE RETURN DUCT THROUGH WALL TO RG-2. SEE DETAIL SHEET M-501.
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
1.
HOPEWELL STREET HOUSING
HP-1
D-4 400 CFM
FILE NAME:
6.17.13 DATE: REVISION:
Hopewell
General Notes
MECHANICAL FLOOR PLAN SHEET:
M-105
Hopewell
4"(10 cm) TYPE "B" VENT CAP (PIN 90502300)
CONDENSATE TO FLOOR DRAIN WITH AIRGAP
ROOF
1
WATER HEATER FLUE DETAIL Scale: N.T.S.
TIE OFF TO ROOF STRUCTURE
NYLON DRAW BAND
Scale: N.T.S.
BRANCH DUCT
SPIN - IN FITTING WITH INSULATION GUARD. BALANCING DAMPER IN BRANCH DUCT.
SPIN-IN TAP FITTING W/AIR SCOOP & DAMPER
FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0" LAY-IN SUPPLY AIR DIFFUSER W/ROUND NECK & O.B.D.
ROOF EXHAUSTER DETAIL
SUPPLY DUCT
METAL BAND SUPPORT
4
2
DUCT LINER (IF REQUIRED) INSULATED FLEXIBLE DUCT, 5' MAX..
DIFFUSER
T-BAR TYPE SUSPENDED CEILING
SUPPLY AIR DIFFUSER DETAIL Scale: N.T.S.
5
CONDENSATE PUMP P-1
3
HEAT PUMP DETAIL Scale: N.T.S.
CJH TOC
FINISH FLOOR
a) Refer to Installation, Operation and Service Manual for proper design. b) Type "B" vent materials must be used outdoors. c) An insulating thimble (P/N 90505600) is required to pass through combustible structures. d) 4" (10 cm) O.D. vent pipe, maximum 45 ft.(13.7m) in length may be used as shown above with an approved vent cap (P/N 90502300). NOTE: Condensate may develop when long vent pipes are used. It is recommended that the pipe length should be less than 20' (6m). e)When heater extension packages are used, they directly effect maximum vent length. Refer to Installation, Operation and Service Manual for requirements.
TGA
24" PLENUM/ PLATFORM
TO INDIRECT WASTE
1752 HOPEWELL SANTA FE , NEW MEXICO
RETURN GRILLE RG-2
APPROVED THIMBLE (PIN 90505600) (IF APPLICABLE)
HOPEWELL STREET HOUSING
VENT ADAPTER
RETURN AIR DUCT THROUGH WALL
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
4"(10 cm) SINGLE WALL PIPE
FILE NAME:
FAN COIL MODULE
THOMAS GIFFORD ARCHITECT
ROOF FLASHING
CLOSET DOOR
MINIMUM
18" (46 cm)
4"(10 cm) TYPE "B" VENT CAP
6.17.13 DATE: REVISION:
SIDE VIEW
SUPPLY AIR DIFFUSER DETAIL Scale: N.T.S.
MECHANICAL DETAILS SHEET:
M-501
EQUIPMENT SCHEDULE
EX-1
CFM
SP-A50
51
ESP
0.125"
0.50
120/1/60
280
VAC/P/HZ
120/1/60
AMPS
1.6
HEAT PUMP: OUTDOOR HEAT PUMP; 2 STAGE SCROLL COMPRESSOR; INTERNAL PRESSURE RELIEF VALVE; INTERNAL THERMAL OVERLOAD; HIGH PRESUURE SWITCH; LOSS OF CHARGE SWITCH; FILTER DRIER; LOW AMBIENT ACCESORY KIT; BAKED ON POWDER PAINT; DENSE WIRE COIL GUARD; CRANK CASE HEATER. MODEL NO. IS CARRIER.
HP-1 25HCA624A0030 24,000 15,300@17°F 257 208/230/1/60 16.2 HP-2 25HCA636A0030 36,000 22,600@17°F 269 208/230/1/60 23.7 HP-3 25HCA648A0030 48,000 29,200@17°F 295 208/230/1/60 29.8 FAN COIL: DX MULTIPOISE FAN COIL; SOLID STATE FAN CONTROL; 1-INCH INSULATION; MULTISPEED MOTOR FOR 2 STAGE COOLING AND CLG/HTG AIRFLOWS; PRE-PAINTED GALVANIZED STEEL CASING; METERING DEVICE AND CLEANABLE, PERMANENT FRAMED FILTER; FACTORY INSTALLED DISCONNECT; FIELD INSTALLED ELECTRICAL RESISTANCE AUXILIARY HEATER WITH INTERNAL CIRCUIT BREAKER HEATER PROTECTION. MODEL NO. IS CARRIER. SYMBOL MODEL NO. CFM/SP CLG/HTG BTUH FC-1 FC-2 FC-3
COOLING HEATING BTUH HP
FV4CNF0020O5 875/0.5 24,000 FV4CNF0030O5 1050/0.5 36,000 FV4CNF0030O5 1400/0.5 48,000
BLOWER
15,300@17°F 1/2 22,600@17°F 1/2 20,200@°F 1/2
VAC/P/HZ AUX. ELEC. 208/230/1/60 208/230/1/60 208/230/1/60
DIFFUSER: "TITUS" SUPPLY AIR GRILLE; MODEL 300RL; STEEL CONSTRUCTION; DOUBLE DEFLECTION; 3/4" BLADE SPACING; ADJUSTABLE BLADES PARALLEL TO LONG DIMENSION; OPPOSED BLADE DAMPER ADJUSTABLE THROUGH FACE; #26 WHITE FINISH. SYMBOL D-1 D-2 D-3 D-4
RG-1 RG-2
P-1
5 KW 5 KW 5 KW
SIZE 6"X6" 8"X6" 10"X6" 12"X10
RETURN GRILLE: TITUS RETURN GRILLE; MODEL 350RL FIXED BLADES AT 3/4" CENTERS PARALLEL TO LONG DIMENSION OF GRILLE; OPPOSED BLADE DAMPER OPERABLE FROM FACE OF GRILLE; FINISH #26 WHITE; ALL STEEL CONSTRUCTION. SYMBOL
SIZE
RG-1 RG-2
36"X36" 18"X18"
CONDENSATE PUMP: LOW PROFILE; VERTICAL TYPE PUMP; LEAK PROOF ABS TANK; 3/8" BARBED DISCHARGE; SAFETY SWITCH; 6' POWER CORD; UL/CSA LISTED; 20' SHUTOFF HEAD; STAINLESS STEEL MOTOR SHAFT. MODEL NO. IS LITTLE GIANT. SYMBOL P-1
MODEL NO.
VCC-20
CAPACITY
80 GAL/HR
HP
VAC/P/HZ
1/30 120/1/60 MODEL NUMBERS GIVEN ARE TO ESTABLISH THE MINIMUM REQUIREMENTS OF THE EQUIPMENT SPECIFIED. IF AN ALTERNATE ITEM EQUALS OR EXCEEDS THE MODEL SPECIFIED, LITERATURE AND/OR SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR APPROVAL.
CJH TOC
30"
CFM
1752 HOPEWELL SANTA FE , NEW MEXICO
QDE30SS
WIDTH
TGA
MODEL #
SYMBOL MODEL NO. COOLING HEATING WEIGHT VAC/P/HZ MCA BTUH BTUH LBS
D-1 D-2 D-3 D-4
Hopewell
AMPS VAC/P/HZ
HOPEWELL STREET HOUSING
RH-1
FC-1 FC-2 FC-3
FILE NAME:
EBB-1
RANGE HOOD: STAINLESS STEEL; TWO POSITION LIGHT; RESILIENT VIBRATION ISOLATION MOTOR MOUNTS; 2 SPEED CENTRIFUGAL FAN; DISHWASHER SAFE ALUMINUM FILTERS; DUCT CONNECTOR WITH BUILT IN DAMPER; FRONT CONTROLS; ENERGY STAR RATING. MODEL NUMBER IS BROAN. SYMBOL
HP-1 HP-2 HP-3
MODEL
DESCRIPTION 6.17.13 DATE: REVISION:
CEILING EXHAUSTER: CEILING MOUNTED SUPER-QUIET EXHAUST FAN; ALUMINUM BACKDRAFT DAMPER; EMBOSSED GALVANIZED STEEL HOUSING; STATIC AND DYNAMICALLY BALANCED CENTRIFUGAL BLOWER; HOODED WALL CAP WITH BIRDSCREEN; CEILING GRILLE. MODEL NUMBERS ARE GREENHECK. CAPACITIES ARE FOR SEA LEVEL. SYMBOL
RH-1
SYMBOL
PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL
[email protected]
EX-1
DESCRIPTION
THOMAS GIFFORD ARCHITECT
SYMBOL
MECHANICAL EQUIPMENT SCHEDULE SHEET:
M-601