DESCRIPTION ABBREVIATIONS AIR CONDITIONER ABOVE FINISHED FLOOR BALANCING DAMPER

Project General Notes BUTTERFLY VALVE DOMESTIC HOT WATER RETURN PIPE GLOBE VALVE NATURAL GAS PIPE GATE VALVE SANITARY VENT PIPE SANITARY PIPE D...
Author: Osborne Lester
21 downloads 0 Views 616KB Size
Project General Notes

BUTTERFLY VALVE

DOMESTIC HOT WATER RETURN PIPE

GLOBE VALVE

NATURAL GAS PIPE

GATE VALVE

SANITARY VENT PIPE SANITARY PIPE

DUCT SMOKE DETECTOR RELAY COIL THERMOSTAT TEMPERATURE SENSOR KEYED NOTE DESIGNATION

ABBREVIATIONS AC

AIR CONDITIONER

A.F.F.

ABOVE FINISHED FLOOR

DRAIN VALVE

BD

BALANCING DAMPER

MANUAL AIR VENT.

BFP

BACK FLOW PREVENTER

GRISWOLD FLOW CONTROL VALVE

CFM

CUBIC FEET PER MIN

CO

CLEANOUT

COTG

CLEANOUT TO GRADE

CW

COLD WATER

TRIPLE DUTY VALVE

DCO

DOUBLE CLEANOUT

CHECK VALVE

DF

DRINKING FOUNTAIN

GAUGE COCK

D-1

DIFFUSER TYPE

ESP

EXT STATIC PRESS

EX

EXHAUST GRILL

EXT, EXIST

EXISTING

GAS PRESSURE REGULATOR

FCO

FLOOR CLEANOUT

GAS SOLENOID VALVE W/HI-LO FIRE

FD

FLOOR DRAIN

FS

FLOOR SINK

FPH

FREEZE PROOF HYDRANT

FHB

FREEZE PROOF HOSE BIBB

F-1

FURNACE TYPE

TWO-WAY CONTROL VALVE PNEUMATIC BYPASS VALVE

BALANCING VALVE GAS COCK

EXHAUST FAN SUPPLY DIFFUSER

T

RELIEF VALVE

RETURN GRILL

PETE'S PLUG

ELECTRIC THERMOSTAT

THERMOMETER W/WELL

UNION

PADDLE TYPE FLOW SWITCH

GPM

GALLONS PER MIN

BALANCING OR PLUG COCK

DIFFERENTIAL PRESSURE FLOW SWITCH

HB

HOSE BIBB

RISE IN PIPING

DIFFERENTIAL PRESSURE SENSOR

HW

HOT WATER

DROP IN PIPING

PRESSURE GAUGE

LAV

LAVATORY

NO.

NUMBER

OSA

OUTSIDE AIR

FLEXIBLE CONNECTOR

PSI

POUNDS PER SQ IN

STRAINER

RG

RETURN GRILL

MALE HOSE CONNECTOR

RM

ROOM

TYP

TYPICAL

UH

UNIT HEATER

UNO

UNLESS NOTED OTHERWISE

PIPE GUIDE

UR

URINAL

PIPE EXPANSION LOOP

VTR

VENT THRU ROOF

EXPANSION JOINT

WCO

WALL CLEANOUT

WC

WATER CLOSET

WH

WATER HEATER

VALVE IN RISE OR DROP D-X 000/000 CFM

SENSOR WELL

DIFFUSER SYMBOL COOLING/HEATING AIRFLOW

PIPING REDUCER PIPE ANCHOR

UNION FLOW ARROW TEE CONNECTION

C.

CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE LAY OUT AND INSTALLATION OF THE PLUMBING SYSTEMS INCLUDING ALL COORDINATION WITH NEW AND EXISTING SERVICES MECHANICAL EQUIPMENT, DUCTWORK AND ELECTRICAL EQUIPMENT.

T.

MECHANICAL AND PLUMBING EQUIPMENT SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS.

U.

CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL COORDINATION OF OUTAGES WITH BOTH THE OWNER AND UTILITY COMPANIES, FOR UTILITY CONNECTIONS.

SANITARY VENT TERMINATIONS SHALL BE A MINIMUM DISTANCE OF 10' HORIZONTALLY OR 3' ABOVE ANY BUILDING OPENING OR AIR INTAKE.

V.

DUCTWORK SHALL BE FABRICATED AND INSTALLED PER SMACNA STANDARDS, AND UMC STANDARDS.

D.

CONTRACTOR SHALL VERIFY INVERTS BEFORE ROUTING ANY PIPING.

E.

WASTE PIPING SHALL BE PVC OR CAST IRON. VENT PIPING MAY BE PVC PIPE OR CAST IRON ABOVE AND BELOW FLOOR, PER UPC LIMITATIONS, AND CITY CODES.

F.

G.

H.

PROVIDE GAS COCKS AND FLEXIBLE CONNECTIONS AT EACH GAS OUTLET OR APPLIANCE.

W. CONTRACTOR SHALL COORDINATE WITH ELECTRICAL AND ARCHITECTURAL TO DETERMINE FINAL DIFFUSERS LOCATIONS. X.

ALL WATER PIPING SHALL BE TYPE M COPPER ABOVE FLOOR AND TYPE L SOFT COPPER BELOW FLOOR OR CROSS LINKED POLYETHYLENE (AQUAPEX) TUBING MEETING ASTM F87-99A ABOVE AND BELOW FLOOR.

Y.

INSULATE SUPPLY DUCTWORK PER TABLE THIS SHEET. WITH FOIL FACED EXTERNAL DUCT WRAP. PROVIDE ALUMINUM ROLL JACKETING MEETING ASTM B-206, H-14 TEMPER, .016" THICKNESS FOR EXTERNAL DUCT. DUCT DIMENSIONS ARE CLEAR INSIDE.

NATURAL GAS PIPING SHALL BE SCHEDULE 40 BLACK STEEL ABOVE GRADE AND SHALL BE EITHER PROTECTED SCH 40 BLACK STEEL WRAPPED OR SDR-11 POLYETHENE BELOW GRADE.

Z.

SEE EQUIPMENT SCHEDULE FOR EQUIPMENT TYPES AND SIZES. MINIMUM BURY DEPTH FOR WATER IS 4' AND 2' FOR GAS.

BB. INSTALL SPLITTERS AT BRANCH CONNECTIONS.

I.

ROUTE PIPING AS NEARLY AS POSSIBLE TO ROUTES INDICATED ON PLANS. CONTRACTOR IS FREE TO MAKE MINOR CHANGES IN ROUTING TO ACCOMMODATE CONDITIONS.

J.

CONTRACTOR RESPONSIBLE FOR ALL REQUIRED TRANSITIONS, OFFSETS MINOR RELOCATIONS, AND ALL ASSOCIATED FITTINGS

K.

CONTRACTOR SHALL INSTALL A COMPLETE OPERATING SYSTEM, INCLUDING REFRIGERANT PIPING, EQUIPMENT, CONTROLS, AND CONDENSATE DRAIN TO APPROVED INDIRECT WASTE.

CC. CONTRACTOR SHALL HAVE INDEPENDENT TEST AND BALANCE CONTRACTOR BALANCE AIR FLOWS PER DRAWINGS AND ADJUST ALL TEMPERATURE AND CONTROL DEVICES. MECHANICAL CONTRACTOR SHALL TEST RUN SYSTEM FOR A PERIOD OF 8 HRS., VERIFIED BY GENERAL CONTRACTOR, BEFORE GIVING NOTICE OF COMPLETION OF WORK. DD. CONTRACTOR SHALL INSTALL A PRESSURE REGULATOR AT THE INCOMING WATER SERVICE IF SITE WATER PRESSURE EXCEEDS 80 P.S.I. REGULATOR SHALL MATCH LINE SIZE. FF. CONTRACTOR SHALL PROVIDE ACCESS PANELS OF APPROPRIATE SIZE FOR ALL INACCESSIBLE REMOTE EQUIPMENT.

ANY LINES ENCOUNTERED WHICH MAY INTERFERE WITH NEW CONSTRUCTION SHALL BE RELOCATED IF ACTIVE AND REMOVED IF INACTIVE.

M.

ALL WATER PIPING LOCATED IN EXTERIOR WALLS OF THE BUILDING SHALL BE INSULATED WITH 1/2" INSULATION AND BE LOCATED ON BUILDING INTERIOR SIDE OF INSULATION. ALL HW/CW, P-TRAPS AT HANDICAPPED LAVATORIES SHALL BE INSULATED.

O.

CONTRACTOR SHALL PROVIDE 12" RISERS, CAPPED AT EACH FIXTURE FOR SHOCK ABSORPTION OR A SHOCK ABSORBER UNIT FOR THE SYSTEM.

P.

PROVIDE WALL CLEAN OUTS AND SHUT OFF VALVES AT ALL SINKS AND WALL MOUNTED URINALS.

Q.

PROVIDE ESCUTCHEONS AT ALL PIPE PENETRATIONS OF WALLS AND FLOORS.

INSTALL TURNING VANES IN RECTANGULAR ELBOWS.

AA. ALL REGISTERS AND DIFFUSERS SHALL HAVE DAMPERS OR EXTRACTORS FOR AIR BALANCING.

L.

N.

GG. CONTRACTOR SHALL NOT MODIFY ANY STRUCTURAL MEMBERS SUCH AS BEAMS, COLUMNS, TRUSSES, ETC. HH. SEE ARCHITECTURAL DRAWINGS FOR ROOF DRAINS. II.

ALL PIPING AND DUCTWORK THAT PENETRATES A FIRE RATED WALL SHALL BE SEALED WITH APPROVED FIRE STOPPING TO RESTORE THE FIRE RATING AND MAKE WEATHER TIGHT AS REQUIRED.

NEW TO EXISTING CONNECTION

MINIMUM DUCT INSULATION

MINIMUM PIPE INSULATION

SEISMIC RESTRAINT FOR WATER HEATERS.

BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTION 803.2.8

BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE 2009, SECTIONS 504.4 AND 504.5.

BASED ON: UNIFORM MECHANICAL CODE SECTION 508.2.

DUCT AND PLENUM INSULATION AND SEALING: ALL SUPPLY AND RETURN DUCTS AND PLENUMS SHALL BE INSULATED WITH A MINIMUN OF R-6 INSULATION WHEN LOCATED IN UNCONDITIONED SPACES AND A MINIMUM OF R-8 INSULATION WHEN LOCATED OUTSIDE THE BUILDING. WHEN LOCATED WITHIN A BUILDING ENVELOPE ASSEMBLY, THE DUCT OR PLENUM SHALL BE SEPARATED FROM THE BUILDING EXTERIOR OR UNCONDITIONED OR EXEMPT SPACES BY A MINIMUM OF R-8 INSULATION.

FOR AUTOMATIC-CIRCULATING HOT WATER SYSTEMS, PIPING SHALL BE INSULATED WITH 1" OF INSULATION HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X°F. THE FIRST 8' OF PIPING IN NONCIRCULATING SYSTEMS SERVED BY EQUIPMENT WITHOUT INTEGRAL HEAT TRAPS SHALL BE INSULATED WITH 0.5" OF MATERIAL HAVING A CONDUCTIVITY NOT EXCEEDING 0.27 BTU PER INCH/HXFT2X°F.

IN SEISMIC DESIGN CATEGORIES C,D,E, AND F, WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE MOTHION. STRAPPING SHALL BE AT POINTS WITHIN THE UPPER ONE-THIRD AND LOWER ONE-THIRD OF ITS VERTICAL DIMENSIONS. AT THE LOWER POINT, A DISTANCE OF NOT LESS THAN 4" SHALL BE MAINTAINED ABOVE THE CONTROLS WITH THE STRAPPING.

EXCEPTIONS: 1. WHEN LOCATED WITHIN EQUIPMENT. 2. WHEN THE DESIGN TEMPERATURE DIFFERENCE BETWEEN THE INTERIOR AND EXTERIOR OF THE DUCT OR PLENUM DOES NOT EXCEED 15°F (8°C).

MINIMUM PIPE INSULATION BASED ON: INTERNATIONAL ENERGY CONSERVATION CODE, SECTION 803.2.8

Hopewell

DOMESTIC HOT WATER PIPE

B.

S.

FILE NAME:

BALL VALVE

DESCRIPTION

TEMPERATURE AND HOT WATER SYSTEM CONTROLS BASED ON: IECC 2009 CODE SECTIONS 504.3 AND 504.6 SERVICE WATER-HEATING EQUIPMENT SHALL BE PROVIDED WITH CONTROLS TO ALLOW A SET POINT OF 110° F FOR EQUIPMENT SERVING DWELLING UNITS AND 90° F FOR EQUIPMENT SERVING OTHER OCCUPANCIES. THE OUTLET TEMPERATURE OF LAVATORIES IN PUBLIC FACILITY REST ROOMS SHALL BE LIMITED TO 110° F. AUTOMATIC - CIRCULATING HOT WATER SYSTEM PUMPS OR HEAT TRACE SHALL BE ARRAINGED TO BE CONVENIENTLY TURNED OFF AUTOMATICALLY OR MANUALLY WHEN THE HOT WATER SYSTEM IS NOT IN OPERATION.

CJH TOC

DOMESTIC COLD WATER PIPE

SYMBOL

TGA

DESCRIPTION

PROVIDE SHUT-OFF VALVES AT PLUMBING RISES.

1752 HOPEWELL SANTA FE , NEW MEXICO

SYMBOL

R.

HOPEWELL STREET HOUSING

G

DESCRIPTION

ALL WORK SHALL BE COMPLETED IN FULL COMPLIANCE WITH THE 2009 UPC, 2009 UMC, 2009 IECC, NFPA AND ALL LOCAL CODES AND ORDINANCES.

6.17.13 DATE: REVISION:

SYMBOL

A.

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

(ALL SYMBOLS MAY NOT BE USED)

THOMAS GIFFORD ARCHITECT

MECHANICAL/PLUMBING SYMBOL LEGEND

MECHANICAL NOTES & LEGEND SHEET:

M-001

UP TO 2rd FLOOR, FLOOR SUPPLY.

D-3 250 CFM 6"Ø

14"X10" D-1

8"Ø

1

D-3 250 CFM

D-1 2

6"Ø

EX-1

3

14"X10"

D-1 40 CFM

RH-1 8"Ø

8"Ø 10"Ø D-3 250 CFM

6"Ø

2

D-3 250 CFM

D-2 125 CFM

2

3

FIRST FLOOR MECHANICAL PLAN HT-2

Scale: 1/4" = 1'0"

2

SECOND FLOOR MECHANICAL PLAN HT-2

Scale: 1/4" = 1'0"

0 2 4

8

16

CJH VNF

3.

TGA

10"Ø

2

DOWN TO 1st FLOOR CEILING SUPPLY.

1752 HOPEWELL SANTA FE , NEW MEXICO

8"Ø

2.

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

3

RECIRCULATE AIR FROM TOP OF STAIR DOWN TO FIRST FLOOR.

THOMAS GIFFORD ARCHITECT

6"Ø

D-2 125 CFM

1.

HOPEWELL STREET HOUSING

Keyed Notes

FC-2

1

FILE NAME:

6.17.13 DATE: REVISION:

HP-2

EX-1

Hopewell

General Notes

1/8" = 1'-0"

MECHANICAL FLOOR PLAN SHEET:

M-101

FILE NAME:

6.17.13 DATE: REVISION:

Hopewell

General Notes

Keyed Notes

Scale: 1/4" = 1'0"

1

SECOND FLOOR MECHANICAL PLAN HT-3

Scale: 1/4" = 1'0"

0 2 4 1/8" = 1'-0"

8

16

24

CJH VNF

1

FIRST FLOOR MECHANICAL PLAN HT-3

HP-2

1752 HOPEWELL SANTA FE , NEW MEXICO

EX-1

EX-1

TGA

FC-2

THOMAS GIFFORD ARCHITECT

RH-1

HOPEWELL STREET HOUSING

CONTRACTOR TO REUSE EXISTING DUCTWORK. SUPPLY AND RETURN AIR GRILLS SHALL BE REPLACED WITH NEW EQUIPMENT.

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

1.

MECHANICAL FLOOR PLAN SHEET:

M-102

FILE NAME:

6.17.13 DATE: REVISION:

Hopewell

General Notes

EX-1

Keyed Notes 1. EX-1

EX-1

1

MECHANICAL PLAN HM-3

Scale: 1/4" = 1'0"

2

MECHANICAL PLAN HM-4

CONTRACTOR TO REUSE EXISTING DUCTWORK. SUPPLY AND RETURN AIR GRILLS SHALL BE REPLACED WITH NEW EQUIPMENT.

Scale: 1/4" = 1'0"

0 2 4 1/8" = 1'-0"

8

16

24

CJH VNF

1

1752 HOPEWELL SANTA FE , NEW MEXICO

HP-2

FC-2

TGA

FC-2

HOPEWELL STREET HOUSING

RH-1

THOMAS GIFFORD ARCHITECT

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

HP-2

MECHANICAL FLOOR PLAN SHEET:

M-103

14"X10"

2

D-3 250 CFM

6"Ø

D-1

EX-1

D-1 8"Ø

1

6"Ø

3

EX-1

Keyed Notes

D-1 40 CFM D-3 250 CFM

2

14"X10" RH-1

8"Ø

2

RECIRCULATE AIR FROM TOP OF STAIR DOWN TO FIRST FLOOR.

2.

DOWN TO 1st FLOOR CEILING SUPPLY.

3.

UP TO 2rd FLOOR, FLOOR SUPPLY.

8"Ø

D-3 250 CFM

D-3 250 CFM

6"Ø

3

1

1.

D-2 125 CFM

2

FIRST FLOOR MECHANICAL PLAN HT-A

Scale: 1/4" = 1'0"

2

SECOND FLOOR MECHANICAL PLAN HT-A

Scale: 1/4" = 1'0"

Legend 0 2 4 1/8" = 1'-0"

8

16

24

FILE NAME:

CJH VNF

8"Ø

1752 HOPEWELL SANTA FE , NEW MEXICO

HP-3

TGA

6"Ø

HOPEWELL STREET HOUSING

D-2 125 CFM

3

THOMAS GIFFORD ARCHITECT

FC-3

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

6.17.13 DATE: REVISION:

Hopewell

General Notes

MECHANICAL FLOOR PLAN SHEET:

M-104

Keyed Notes

1

MECHANICALFLOOR PLAN

Scale: 1/4" = 1'0"

0 2 4 1/8" = 1'-0"

8

16

24

CJH VNF

D-4 400 CFM

1752 HOPEWELL SANTA FE , NEW MEXICO

EX-1

TGA

EBB-1

THOMAS GIFFORD ARCHITECT

FC-1 RG-2 1

MOUNT FAN COIL ON GALVANIZED METAL PLATFORM. PROVIDE RETURN DUCT THROUGH WALL TO RG-2. SEE DETAIL SHEET M-501.

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

1.

HOPEWELL STREET HOUSING

HP-1

D-4 400 CFM

FILE NAME:

6.17.13 DATE: REVISION:

Hopewell

General Notes

MECHANICAL FLOOR PLAN SHEET:

M-105

Hopewell

4"(10 cm) TYPE "B" VENT CAP (PIN 90502300)

CONDENSATE TO FLOOR DRAIN WITH AIRGAP

ROOF

1

WATER HEATER FLUE DETAIL Scale: N.T.S.

TIE OFF TO ROOF STRUCTURE

NYLON DRAW BAND

Scale: N.T.S.

BRANCH DUCT

SPIN - IN FITTING WITH INSULATION GUARD. BALANCING DAMPER IN BRANCH DUCT.

SPIN-IN TAP FITTING W/AIR SCOOP & DAMPER

FLEX DUCT WITH 2" EXTERNAL INSULATION MAX. LENGTH 5'-0" LAY-IN SUPPLY AIR DIFFUSER W/ROUND NECK & O.B.D.

ROOF EXHAUSTER DETAIL

SUPPLY DUCT

METAL BAND SUPPORT

4

2

DUCT LINER (IF REQUIRED) INSULATED FLEXIBLE DUCT, 5' MAX..

DIFFUSER

T-BAR TYPE SUSPENDED CEILING

SUPPLY AIR DIFFUSER DETAIL Scale: N.T.S.

5

CONDENSATE PUMP P-1

3

HEAT PUMP DETAIL Scale: N.T.S.

CJH TOC

FINISH FLOOR

a) Refer to Installation, Operation and Service Manual for proper design. b) Type "B" vent materials must be used outdoors. c) An insulating thimble (P/N 90505600) is required to pass through combustible structures. d) 4" (10 cm) O.D. vent pipe, maximum 45 ft.(13.7m) in length may be used as shown above with an approved vent cap (P/N 90502300). NOTE: Condensate may develop when long vent pipes are used. It is recommended that the pipe length should be less than 20' (6m). e)When heater extension packages are used, they directly effect maximum vent length. Refer to Installation, Operation and Service Manual for requirements.

TGA

24" PLENUM/ PLATFORM

TO INDIRECT WASTE

1752 HOPEWELL SANTA FE , NEW MEXICO

RETURN GRILLE RG-2

APPROVED THIMBLE (PIN 90505600) (IF APPLICABLE)

HOPEWELL STREET HOUSING

VENT ADAPTER

RETURN AIR DUCT THROUGH WALL

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

4"(10 cm) SINGLE WALL PIPE

FILE NAME:

FAN COIL MODULE

THOMAS GIFFORD ARCHITECT

ROOF FLASHING

CLOSET DOOR

MINIMUM

18" (46 cm)

4"(10 cm) TYPE "B" VENT CAP

6.17.13 DATE: REVISION:

SIDE VIEW

SUPPLY AIR DIFFUSER DETAIL Scale: N.T.S.

MECHANICAL DETAILS SHEET:

M-501

EQUIPMENT SCHEDULE

EX-1

CFM

SP-A50

51

ESP

0.125"

0.50

120/1/60

280

VAC/P/HZ

120/1/60

AMPS

1.6

HEAT PUMP: OUTDOOR HEAT PUMP; 2 STAGE SCROLL COMPRESSOR; INTERNAL PRESSURE RELIEF VALVE; INTERNAL THERMAL OVERLOAD; HIGH PRESUURE SWITCH; LOSS OF CHARGE SWITCH; FILTER DRIER; LOW AMBIENT ACCESORY KIT; BAKED ON POWDER PAINT; DENSE WIRE COIL GUARD; CRANK CASE HEATER. MODEL NO. IS CARRIER.

HP-1 25HCA624A0030 24,000 15,300@17°F 257 208/230/1/60 16.2 HP-2 25HCA636A0030 36,000 22,600@17°F 269 208/230/1/60 23.7 HP-3 25HCA648A0030 48,000 29,200@17°F 295 208/230/1/60 29.8 FAN COIL: DX MULTIPOISE FAN COIL; SOLID STATE FAN CONTROL; 1-INCH INSULATION; MULTISPEED MOTOR FOR 2 STAGE COOLING AND CLG/HTG AIRFLOWS; PRE-PAINTED GALVANIZED STEEL CASING; METERING DEVICE AND CLEANABLE, PERMANENT FRAMED FILTER; FACTORY INSTALLED DISCONNECT; FIELD INSTALLED ELECTRICAL RESISTANCE AUXILIARY HEATER WITH INTERNAL CIRCUIT BREAKER HEATER PROTECTION. MODEL NO. IS CARRIER. SYMBOL MODEL NO. CFM/SP CLG/HTG BTUH FC-1 FC-2 FC-3

COOLING HEATING BTUH HP

FV4CNF0020O5 875/0.5 24,000 FV4CNF0030O5 1050/0.5 36,000 FV4CNF0030O5 1400/0.5 48,000

BLOWER

15,300@17°F 1/2 22,600@17°F 1/2 20,200@°F 1/2

VAC/P/HZ AUX. ELEC. 208/230/1/60 208/230/1/60 208/230/1/60

DIFFUSER: "TITUS" SUPPLY AIR GRILLE; MODEL 300RL; STEEL CONSTRUCTION; DOUBLE DEFLECTION; 3/4" BLADE SPACING; ADJUSTABLE BLADES PARALLEL TO LONG DIMENSION; OPPOSED BLADE DAMPER ADJUSTABLE THROUGH FACE; #26 WHITE FINISH. SYMBOL D-1 D-2 D-3 D-4

RG-1 RG-2

P-1

5 KW 5 KW 5 KW

SIZE 6"X6" 8"X6" 10"X6" 12"X10

RETURN GRILLE: TITUS RETURN GRILLE; MODEL 350RL FIXED BLADES AT 3/4" CENTERS PARALLEL TO LONG DIMENSION OF GRILLE; OPPOSED BLADE DAMPER OPERABLE FROM FACE OF GRILLE; FINISH #26 WHITE; ALL STEEL CONSTRUCTION. SYMBOL

SIZE

RG-1 RG-2

36"X36" 18"X18"

CONDENSATE PUMP: LOW PROFILE; VERTICAL TYPE PUMP; LEAK PROOF ABS TANK; 3/8" BARBED DISCHARGE; SAFETY SWITCH; 6' POWER CORD; UL/CSA LISTED; 20' SHUTOFF HEAD; STAINLESS STEEL MOTOR SHAFT. MODEL NO. IS LITTLE GIANT. SYMBOL P-1

MODEL NO.

VCC-20

CAPACITY

80 GAL/HR

HP

VAC/P/HZ

1/30 120/1/60 MODEL NUMBERS GIVEN ARE TO ESTABLISH THE MINIMUM REQUIREMENTS OF THE EQUIPMENT SPECIFIED. IF AN ALTERNATE ITEM EQUALS OR EXCEEDS THE MODEL SPECIFIED, LITERATURE AND/OR SAMPLES SHALL BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR APPROVAL.

CJH TOC

30"

CFM

1752 HOPEWELL SANTA FE , NEW MEXICO

QDE30SS

WIDTH

TGA

MODEL #

SYMBOL MODEL NO. COOLING HEATING WEIGHT VAC/P/HZ MCA BTUH BTUH LBS

D-1 D-2 D-3 D-4

Hopewell

AMPS VAC/P/HZ

HOPEWELL STREET HOUSING

RH-1

FC-1 FC-2 FC-3

FILE NAME:

EBB-1

RANGE HOOD: STAINLESS STEEL; TWO POSITION LIGHT; RESILIENT VIBRATION ISOLATION MOTOR MOUNTS; 2 SPEED CENTRIFUGAL FAN; DISHWASHER SAFE ALUMINUM FILTERS; DUCT CONNECTOR WITH BUILT IN DAMPER; FRONT CONTROLS; ENERGY STAR RATING. MODEL NUMBER IS BROAN. SYMBOL

HP-1 HP-2 HP-3

MODEL

DESCRIPTION 6.17.13 DATE: REVISION:

CEILING EXHAUSTER: CEILING MOUNTED SUPER-QUIET EXHAUST FAN; ALUMINUM BACKDRAFT DAMPER; EMBOSSED GALVANIZED STEEL HOUSING; STATIC AND DYNAMICALLY BALANCED CENTRIFUGAL BLOWER; HOODED WALL CAP WITH BIRDSCREEN; CEILING GRILLE. MODEL NUMBERS ARE GREENHECK. CAPACITIES ARE FOR SEA LEVEL. SYMBOL

RH-1

SYMBOL

PO BOX 31934 SANTA FE , NEW MEXICO 87594 PHONE 505.690.5898 FACSIMILE 505.982.7884 EMAIL [email protected]

EX-1

DESCRIPTION

THOMAS GIFFORD ARCHITECT

SYMBOL

MECHANICAL EQUIPMENT SCHEDULE SHEET:

M-601