View of company Work Flow Concept of CAD/CAM System Packing design Un-packing Protocol ALIA Locking Abutment ALIPS Locking Abutment Screw Mountless driver system Length of the implant(EST, SST, IST, IT) Introduction of SG Implant EST System - External Slightly Tapered Fixture(EST) - Prosthetic Flow diagrams and components for Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment, Temporary Abutment. - Prosthetic Flow diagrams and components for Estheticone, Midicone, Widecone, Locking Abutment. - Prosthetic Flow diagrams and components for O-Ring Abutment.

29

SST System - Internal Submerged Slightly Tapered Fixture(SST) - Prosthetic Flow diagrams and components for Sub-Solid Abutment. - Prosthetic Flow diagrams and components for Sub-Cemented Abutment, Sub-Angled Abutment, Sub-Temporary Abutment, Sub-Gold Abutment. - Prosthetic Flow diagrams and components for Sub-Locking Abutment. - Prosthetic Flow diagrams and components for Sub-O-Ring Abutment.

43

IST System - Internal Slightly Tapered Fixture(IST)

47

IT System - Internal Tapered Fixture(IT) - Prosthetic Flow diagrams and components for Solid Abutment, Excellent Solid Abutment. - Prosthetic Flow diagrams and components for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment. - Prosthetic Flow diagrams and components for Octa Abutment. - Prosthetic Flow diagrams and components for O-Ring Abutment.

65

Surgical Instrument - Surgical Instrument for EST, SST, IST, IT - Drill system - Surgical Drilling protocol and Dimensions - Surgical protocol for EST, SST, IST, IT - Surgical kit contents

02

SHINSAEGI MEDI-TECH

View of company

Company : SHINSAEGI Medi-Tech Co., Ltd. Head office & Manufacture Address : Busan-city, Gang Seu-Gu, Ji Sa-Dong 1212, Korea TEL : 82-51-971-2811

FAX : 82-51-971-2814

E-mail : [email protected] Homepage : http://sgimplant.com Business : Medical Instrument Manufacture & Marketing Product : Dental Implant (Manufacture&Marketing ) Dental CAD/CAM ( Manufacture&Marketing) Titanium & Stainless ( Import & Marketing ) Dental Materials & Instrument ( Manufacture & Marketing)

SHINSAEGI MEDI-TECH

03

Work Flow Concept of CAD/CAM System

Preparation

Model Preparation

Scanning

Sintering

Milling M/C

Design

Veneering

Cementation

Scanning

04

SHINSAEGI MEDI-TECH

Packing design

This Ampule has been divided color for easy Narrow(Red) Regular(Yellow) Wide(Green) Wide 6.0(Blue)

Narrow

Regular

Wide

Wide 6.0

Implant Un-packing Protocol

1

Remove contents from the implant box.

2

Peel back the tray lid to expose the implant.

3

Draw open a cover of implant.

4

Pick-up the implant from the surgical ampule using the fixture mount driver.

5

Mountless delivery system for easy and safety.

SHINSAEGI MEDI-TECH

05

ALIA Locking Abutment This innovate Locking Abutment released from Screw loosening.

External Hex Type (EST)

[ Patent No. US 7.393.210 B2 ]

Submerged Internal Hex Type (SST)

Internal Octa Type (IST&IT)

ALIPS Locking Abutment Screw ALIPS (Anti Lock Inner Post Screw)

[ Patent No. US 6.857.874 B2 ]

External Hex Type (EST)

Submerged Internal Hex Type (SST)

06

SHINSAEGI MEDI-TECH

Internal Octa Type (IST&IT)

Mountless driver system Pick-up and delivery of implant

External Hex Type (EST)

Submerged Internal Hex Type (SST)

Internal Octa Type (IST&IT)

- Care must be taken when inserting the implant placement driver tip into the implant. - A very low RPM speed must be used as you approach the internal hex and octa connection and external hex connection of the implant with the driver tip.

Length of the implant(EST, SST, IST, IT)

0.75 mm

1.8 mm

Length(L) 7, 9, 11, 13, 15mm

EST

SST

IST

IT

- Regardless of the implant type, the length of the implant is the same from the top of the implant collar(platform) to the tip of the implant.

SHINSAEGI MEDI-TECH

07

Introduction of SG Implant External Slightly Tapered Fixture (EST) H

Size (mm) Length L0

Hex H

Apex A

3.4 3.4 3.4 3.4

9.0 11.0 13.0 15.0

2.4 2.4 2.4 2.4

2.2 2.2 2.2 2.2

4.1 4.1 4.1 4.1 4.1

4.0 4.0 4.0 4.0 4.0

7.0 9.0 11.0 13.0 15.0

2.7 2.7 2.7 2.7 2.7

2.6 2.6 2.6 2.6 2.6

EFSW507 EFSW509 EFSW511 EFSW513 EFSW515

5.1 5.1 5.1 5.1 5.1

5.0 5.0 5.0 5.0 5.0

7.0 9.0 11.0 13.0 15.0

3.4 3.4 3.4 3.4 3.4

3.4 3.4 3.4 3.4 3.4

EFSW607 EFSW609 EFSW611 EFSW613

5.1 5.1 5.1 5.1

5.9 5.9 5.9 5.9

7.0 9.0 11.0 13.0

3.4 3.4 3.4 3.4

4.5 4.5 4.5 4.5

Size (mm) Length L0

Hex H

Apex A

No

Code

1 2 3 4

EFSN309 EFSN311 EFSN313 EFSN315

3.5 3.5 3.5 3.5

5 6 7 8 9

EFSR407 EFSR409 EFSR411 EFSR413 EFSR415

10 11 12 13 14 15 16 17 18

Diameter D0

Diameter D1

D0

L0

A D1

Submerged Slightly Tapered Fixture(SST) H

No

Code

1 2 3 4

SFSN309 SFSN311 SFSN313 SFSN315

3.8 3.8 3.8 3.8

3.75 3.75 3.75 3.75

9.0 11.0 13.0 15.0

2.5 2.5 2.5 2.5

2.2 2.2 2.2 2.2

5 6 7 8 9

SFSR407 SFSR409 SFSR411 SFSR413 SFSR415

4.3 4.3 4.3 4.3 4.3

4.2 4.2 4.2 4.2 4.2

7.0 9.0 11.0 13.0 15.0

2.5 2.5 2.5 2.5 2.5

2.9 2.9 2.9 2.9 2.9

10 11 12 13 14

SFSW507 SFSW509 SFSW511 SFSW513 SFSW515

5.0 5.0 5.0 5.0 5.0

4.9 4.9 4.9 4.9 4.9

7.0 9.0 11.0 13.0 15.0

2.5 2.5 2.5 2.5 2.5

3.6 3.6 3.6 3.6 3.6

15 16 17 18

SFSW607 SFSW609 SFSW611 SFSW613

6.0 6.0 6.0 6.0

5.9 5.9 5.9 5.9

7.0 9.0 11.0 13.0

2.5 2.5 2.5 2.5

4.3 4.3 4.3 4.3

Diameter D0

Diameter D1

D0

L0

A D1

08

SHINSAEGI MEDI-TECH

Introduction of SG Implant Internal Slightly Tapered Fixture(IST) O

Size (mm) Length L0

Octa O

Apex A

4.1 4.1 4.1 4.1 4.1

7.0 9.0 11.0 13.0 15.0

3.1 3.1 3.1 3.1 3.1

2.4 2.4 2.4 2.4 2.4

4.8 4.8 4.8 4.8 4.8

4.8 4.8 4.8 4.8 4.8

7.0 9.0 11.0 13.0 15.0

3.1 3.1 3.1 3.1 3.1

2.6 2.6 2.6 2.6 2.6

6.0 6.0 6.0 6.0

5.3 5.3 5.3 5.3

7.0 9.0 11.0 13.0

3.1 3.1 3.1 3.1

4.0 4.0 4.0 4.0

Size (mm) Length L0

Octa O

Apex A

No

Code

1 2 3 4 5

IFSR407 IFSR409 IFSR411 IFSR413 IFSR415

4.8 4.8 4.8 4.8 4.8

6 7 8 9 10

IFSW507 IFSW509 IFSW511 IFSW513 IFSW515

11 12 13 14

IFSW607 IFSW609 IFSW611 IFSW613

Diameter D0

Diameter D1

D0

1.8

L0

A D1

Internal Tapered Fixture(IT) O

No

Code

1 2 3 4 5

IFTR407 IFTR409 IFTR411 IFTR413 IFTR415

4.8 4.8 4.8 4.8 4.8

4.1 4.1 4.1 4.1 4.1

7.0 9.0 11.0 13.0 15.0

3.1 3.1 3.1 3.1 3.1

2.4 2.4 2.4 2.4 2.4

6 7 8 9 10

IFTW507 IFTW509 IFTW511 IFTW513 IFTW515

4.8 4.8 4.8 4.8 4.8

4.8 4.8 4.8 4.8 4.8

7.0 9.0 11.0 13.0 15.0

3.1 3.1 3.1 3.1 3.1

3.1 3.1 3.1 3.1 3.1

11 12 13 14

IFTW607 IFTW609 IFTW611 IFTW613

6.0 6.0 6.0 6.0

5.3 5.3 5.3 5.3

7.0 9.0 11.0 13.0

3.1 3.1 3.1 3.1

3.6 3.6 3.6 3.6

Diameter D0

Diameter D1

D0

1.8

L0

A D1

SHINSAEGI MEDI-TECH

09

10

SHINSAEGI MEDI-TECH

External Fixture Esthetic & Innovation

SHINSAEGI MEDI-TECH SHINSAEGI MEDI-TECH

11

EST System

01 02

03 04 05 06 07 08

09

10

12

Cover Screw Headless Cover Screw Healing Abutment Cemented Abutment Cemented Abutment T-Type Cemented Abutment Screw Cemented Abutment Screw (T-Type) ALIPS Locking Abutment Screw Fixture Lab Analog(UCLA) Angled Abutment Angled Abutment Screw UCLA Gold Abutment UCLA Plastic Abutment UCLA Temporary Abutment Impression Coping(Pick-up) Guide Pin(Pick-up) Impression Coping(Transfer) Guide Pin(Transfer) Conical Abutment Conical Abutment Screw Conical Healing Cap Conical Gold Cylinder Conical Plastic Cylinder Conical Temporary Cylinder Conical Cylinder Screw Conical Impression Coping(pick-up) Conical Guide Pin(pick-up) Conical Impression Coping (Transfer) Conical Lab Analog ALIA External Locking Abutment (Hex) External Locking Abutment Screw External YK Transfer Adapter External YK Transfer Screw Impression Plastic Cap External Locking Lab Analog O-Ring Abutment O-Ring O-Ring Retainer O-Ring Lab Analog

SHINSAEGI MEDI-TECH

16p 16p 16p 17p 17p 17p 18p 18p 18p 18p 19p 19p 19p 19p 20p 20p 20p 20p 22p 22p 22p 22p 23p 23p 23p 23p 24p 24p 24p 24p 25p 25p 25p 25p 25p 27p 27p 27p 27p

EST Implant components and Branemark, 3i, implant components are fully interchangeable.

The inner of head

Flapless surgery - Head design is the same diameter as the implant body - This implant ideal for surgery No counter sinking - This makes the surgical procedure faster and simple.

Micro groove

Apex Body design

Slightly taper -This design for increased initial stablity in soft bone Unique grooves -Increase stability compared to "v"type thread implant

SHINSAEGI MEDI-TECH

INTERNAL (IST.IT)

Sharp tip on 3-cutting edge -This sharp tip also secures a smooth insertion without the implant wobbling -Implant will not spin and loss stablity when a higher density area in reached -This thread design make the implant a very efficient selftapping unit.

INTERNAL (IST.IT)

- Acheive both soft and hard tissue attachement - Generate strong attachment of cortical bone - Superior primary stability

SUBMERGED (SST)

External Hex connection Hex height-0.75mm

Body of head

EXTERNAL (EST)

External Slightly Tapered Fixture(EST System)

13

External Slightly Tapered Fixture (EST System) Feature

- Submerged External hex connection (Hex height 2.7mm) - Apex size : Narrow( 2.2mm), Regular( 2.6mm), Wide( 3.4mm), Wide6.0( 4.5mm) - Torque recommendation : 40Ncm

Narrow

EST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

3.5

L

Head Diameter (D1)

3.5

Body Diameter (D2)

3.4

Hex (H)

2.4

Hex

Length (L)

Code

9

EFSN309

11

EFSN311

13

EFSN313

15

EFSN315

D2

Regular

EST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

4.1

L

Head Diameter (D1)

4.1

Body Diameter (D2)

4.0

Hex (H)

2.7

Hex

Length (L)

Code

7

EFSR407

9

EFSR409

11

EFSR411

13

EFSR413

15

EFSR415

D2

Wide

EST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

L

5.1

Head Diameter (D1)

5.1

Body Diameter (D2)

5.0

Hex (H)

3.4

Hex

Length (L)

Code

7

EFSW507

9

EFSW509

11

EFSW511

13

EFSW513

15

EFSW515

D2

Wide6.0

EST System

Unit : mm

Platform Diameter (D0)

D1 D0

5.1 L Hex

D2

14

SHINSAEGI MEDI-TECH

Head Diameter (D1)

6.0

Body Diameter (D2)

5.9

Hex (H)

3.4

Length (L)

Code

7

EFSW607

9

EFSW609

11

EFSW611

13

EFSW613

Prosthetic Flow Diagrams For EST System Cement Retained Restoration : Cemented Abutment, Angled Abutment, UCLA Gold Abutment, UCLA Plastic Abutment, Temporary Abutment

68p 18p

69p

18p

ALIPS Driver

ALIPS Screw

18p

17p

(Hex) (Non Hex) Cemented Abutment

Abutment Screw

Angled Abutment

19p

(Hex) (Non Hex) UCLA Gold Abutment

1.2Hex Torque Driver

19p

(Hex) (Non Hex) UCLA Plastic Abutment

19p

(Hex) (Non Hex) UCLA Temporary Abutment

18p

Fixture Lab Analog (Narrow) (Regular) (Wide)

20p

20p

(Hex) (Non Hex) Fixture Impression Coping (Pick-up)

(Hex) (Non Hex) Fixture Impression Coping (Transfer)

67p

67p

16p 16p 16p

0.9Hex Hand Driver

Cover Screw

Headless Cover Screw

Healing Abutment

1.2Hex Hand Driver

14p

Fixture(EST)

SHINSAEGI MEDI-TECH

15

EST System

01 Cover Screw

- Head height : 1.5mm - Instrumentation required 0.9hex hand driver - Torque recommendation : 5˜8Ncm Fixture Platform 3.5 (Narrow) 4.1 (Regular)

1.5

5.1

Headless Cover Screw

Code ESVN350

1.5

ESVR410 ESVW510

(Wide)

- Instrumentation required 0.9hex hand driver - Torque recommendation : 5˜8Ncm Fixture Platform

Healing Abutment

Unit : mm

Head Height (H)

Unit : mm

Code

3.5 (Narrow) 4.1 (Regular)

ESHN350

5.1

ESHW510

ESHR410

(Wide)

- Select the height according to the gingival height (2, 3, 4, 5.5, 7mm) - Healing size marked for easy identification (Emergence profile, Restorative, Height) - Instrumentation required 1.2hex hand driver - Torque recommendation : 5˜8Ncm

Unit : mm

2

3

G/H 4

4.0

EHAN402

EHAN403

EHAN404

EHAN405

EHAN407

5.0 6.0 6.0 7.0 8.0 5.0 5.6 6.0 6.8

EHAR502

EHAR503

EHAR504

EHAR505

EHAR507

EHAR602

EHAR603

EHAR604

EHAR605

EHAR607

EHAW602

EHAW603

EHAW604

EHAW605

EHAW607

EHAW702

EHAW703

EHAW704

EHAW705

EHAW707

EHAW802

EHAW803

EHAW804

EHAW805

EHAW807

THAW502

THAW503

THAW504

THAW505

THAW507

THAW602

THAW603

THAW604

THAW605

THAW607

THSW602

THSW603

THSW604

THSW605

THSW607

THSW702

THSW703

THSW704

THSW705

THSW707

Fixture DiamPlatform eter(D) 3.5 G/H

(Narrow)

4.1 (Regular) D

5.1 (Wide)

5.0

(Wide) T-Type

6.0

(Wide) T-Type

16

SHINSAEGI MEDI-TECH

5.5

7

EST System

02 Cemented Abutment

- Cemented retained restorations - Height is 8mm with marked groove 6mm and 7mm for easy cutting - Collar height : 1, 2 ,3, 4mm - Packing unit : Included abutment screw (EACN Series + ESATN35, EACRSeries+ESATR41, EACW Series + ESATW51) - Torque recommendation : 30Ncm

Unit : mm

Gold

Ti

Fixture Diameter Height Type Platform (D) (H) 6

7

8(H)

3.5 G/H

(Narrow)

4.0

D

5.0 4.1 Hex

(Regular)

6.0

Non-Hex

6.0 5.1

(Wide)

7.0 8.0

Cemented Abutment T-Type

Gold

Ti

Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex

8 8 8 8 8 8 8 8 8 8 8 8

7(H)

3.4 (Narrow)

3.8

D

5.0 4.1 Hex

(Regular)

6.0

Non-Hex

5.5 5.0

(Wide)

6.0 6.0

Cemented Abutment Screw

1

2

3

6.0

Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex Hex Non-Hex

7 7 7 7 7 7 7 7 7 7 7 7

4

EACN418H EACN428H EACN438H EACN448H EACN418N EACN428N EACN438N EACN448N EACR518H EACR528H EACR538H EACR548H EACR518N EACR528N EACR538N EACR548N EACR618H EACR628H EACR638H EACR648H EACR618N EACR628N EACR638N EACR648N EACW618H EACW628H EACW638H EACW648H EACW618N EACW628N EACW638N EACW648N EACW718H EACW728H EACW738H EACW748H EACW718N EACW728N EACW738N EACW748N EACW818H EACW828H EACW838H EACW848H EACW818N EACW828N EACW838N EACW848N

- Cement retained restoration - Combined T-type cemented abutment - Height is fixed 7mm - Packing unit : Included abutment screw (TACN, TACR, TACW Series +ESATR41 or ESAGR41) - Torque recommendation : 30Ncm Fixture Diameter Height Type Platform (D) (H)

G/H

G/H

Unit : mm

G/H 1

2

3

4

TACN417H TACN427H TACN437H TACN447H TACN417N TACN427N TACN437N TACN447N TACR517H TACR527H TACR537H TACR547H TACR517N TACR527N TACR537N TACR547N TACR617H TACR627H TACR637H TACR647H TACR617N TACR627N TACR637N TACR647N TACW517H TACW527H TACW537H TACW547H TACW517N TACW527N TACW537N TACW547N TACW617H TACW627H TACW637H TACW647H TACW617N TACW627N TACW637N TACW647N TACS617H TACS627H TACS637H TACS647H TACS617N TACS627N TACS637N TACS647N

- Instrumentation required 1.2hex Torque driver - For use Cemented Abutment, T-Type Cemented Abutment & Temporary Abutment, UCLA Gold Abutment, UCLA Plastic Abutment

Unit : mm

Fixture Platform 3.5 (Narrow) Gold

Thread (T) M 1.6

Ti

4.1 (Regular)

M 2.0

5.1 (Wide)

M 2.5

Ti/Gold

Type

Code

Ti

Hex

ESATN35

Gold

Hex

ESAGN35

Ti

Hex

ESATR41

Gold

Hex

ESAGR41

Ti

Hex

ESATW51

Gold

Hex

ESAGW51

SHINSAEGI MEDI-TECH

17

EST System Cemented Abutment Screw (T-Type)

Unit : mm

Fixture Platform

Gold

3.4 4.1 5.0

Ti

ALIPS Locking Abutment Screw

Thread (T)

Ti/Gold

Type

Code

Ti

Hex

ESATR41

Gold

Hex

ESAGR41

M 2.0

- For use cemented abutment - ALIPS(Anti Lock Inner Post Screw) - Instrumentation required ALIPS driver Fixture Platform

Unit : mm

Thread (T)

Code

3.5 (Narrow)

M 1.6

ESAP001

4.1 (Regular) 5.1 (Wide)

M 2.0

ESAP002

M 2.5

ESAP003

Fixture Lab Analog(UCLA)

Unit : mm

Fixture Platform

03 Angled Abutment

7

Type

Code

3.5 (Narrow)

Hex

ELUN350

4.1 (Regular)

Hex

ELUR410

5.1 (Wide)

Hex

ELUW510

5.0(Wide) T-Type

Hex

TLUW500

6.0 (Wide) T-Type

Hex

TLUS600

- Cement retained restorations - Angulation : 15 , 25 - Collar height : 2mm, 4mm - Packing unit : Included abutment screw (EAAN Series + ESAAN35, EAAR Series + ESAAR41, EAAW Series + ESAAW51, TAAW Series + ESAAR41) - Torque recommendation : 30Ncm Fixture Platform

Diameter (D)

G/H

3.5 (Narrow)

4.0 5.0

D

4.1 (Regular) 6.0 5.1 (Wide) 5.0(Wide) T-Type

18

SHINSAEGI MEDI-TECH

6.0 6.0

G/H 2 4 2 4 2 4 2 4 2 4

Unit : mm

Angel 15

25

EAAN4215

EAAN4225

EAAN4415

EAAN4425

EAAR5215

EAAR5225

EAAR5415

EAAR5425

EAAR6215

EAAR6225

EAAR6415

EAAR6425

EAAW6215

EAAW6225

EAAW6415

EAAW6425

TAAW6215

TAAW6225

TAAW6415

TAAW6425

EST System Angled Abutment Screw

- Instrumentation required 1.2hex Torque driver Fixture Platform

Code

3.5 (Narrow)

04 UCLA Gold Abutment Gold

ESAAR41

5.1 (Wide)

ESAAW51

- Screw retained restoration - Gold alloy - Packing unit : Included abutment screw - Torque recommendation : 30Ncm

3.5 (Narrow)

Hex

Non-Hex

ESAAN35

4.1 (Regular)

Fixture Platform

Ti

4.0

4.1 (Regular)

4.5

5.1 (Wide)

5.5

5.0(Wide) T-Type

5.5

Fixture Platform 3.5 (Narrow)

Diameter (D) 4.0

4.1 (Regular)

4.5

5.1 (Wide)

5.5

5.0(Wide) T-Type

5.5

Non-Hex D

06 UCLA Temporary Abutment Ti

Fixture Platform

Diameter (D) 4.0

4.1 (Regular)

4.5

5.1 (Wide)

5.5

Non-Hex D

Code

Hex

EAGN00H

Non-Hex

EAGN00N

Hex

EAGR00H

Non-Hex

EAGR00N

Hex

EAGW00H

Non-Hex

EAGW00N

Hex

TAGW00H

Non-Hex

TAGW00N

Unit : mm

Type

Code

Hex

EAPN00H

Non-Hex

EAPN00N

Hex

EAPR00H

Non-Hex

EAPR00N

Hex

EAPW00H

Non-Hex

EAPW00N

Hex

TAPW00H

Non-Hex

TAPW00N

- Temporary restoration - Packing unit : Included abutment screw (ETUN Series+ ESATN35, ETURSeries + ESATR41, ETUWSeries + ESATW51, TTUW Series + ESATR41) - Torque recommendation : 15Ncm

3.5 (Narrow)

Hex

Type

- Screw retained restoration - Packing unit : Included Abutment Screw - Torque recommendation : 30Ncm

Ti

Hex

Unit : mm

Diameter (D)

D

05 UCLA Plastic Abutment

Unit : mm

5.0(Wide) T-Type

5.5

Unit : mm

Type

Code

Hex

ETUN40H

Non-Hex

ETUN40N

Hex

ETUR50H

Non-Hex

ETUR50N

Hex

ETUW60H

Non-Hex

ETUW60N

Hex

TTUW60H

Non-Hex

TTUW60N

SHINSAEGI MEDI-TECH

19

EST System

07 Impression Coping(Pick-up)

- Length : 12mm - Packing unit : Included guide pin Fixture Platform

Unit : mm

Diameter (D)

3.5 (Narrow)

Type

4.0 5.0

4.1 (Regular) 6.0 6.0

5.1 (Wide)

5.5 Non-Hex

Hex

5.0(Wide) T-Type

D

6.0

Guide Pin(Pick-up)

Hex

EIPN40H

Non-Hex

EIPN40N

Hex

EIPR50H

Non-Hex

EIPR50N

Hex

EIPR60H

Non-Hex

EIPR60N

Hex

EIPW60H

Non-Hex

EIPW60N

Hex

TIPW55H

Non-Hex

TIPW55N

Hex

TIPW60H

Non-Hex

TIPW60N

- Instrument required 1.2hex driver

Unit : mm

Fixture Platform

Height (H)

Code

Narrow

15 15 17 15

ESGPN150

H

Regular Wide

Impression Coping(Transfer)

Code

ESGPR150 ESGPR170 ESGPW150

- Hex type(Two-piece) - Non hex type(One-piece, Two-piece) Fixture Platform

Diameter (D)

3.5 (Narrow)

4.5

4.1 (Regular)

5.0

5.1 (Wide)

6.0

Unit : mm

Type

Code

Hex

EITN45H

Non-Hex

EITN45N

Hex

EITR50H

Non-Hex

EITR50N

Hex

EITW60H

Non-Hex

EITW60N

Non-Hex

Hex D

Guide Pin(Transfer)

Unit : mm

Fixture Platform

20

SHINSAEGI MEDI-TECH

Code

3.5 (Narrow)

ESGTN35

4.1 (Regular) 5.1 (Wide)

ESGTW51

ESGTR41

Prosthetic Flow Diagrams For EST System Screw Retained restoration : Estheticone, Midicone, Widecone, T-Type Widecone Abutment, Locking Abutment. 68p 25p 68p

22p

69p

1.2Hex Torque Driver

Cylinder Screw 23p

22p

Conical Gold Cylinder

23p

1.2Hex Torque Driver

ALIA EXternal Locking Abutment Screw

Repositioning Jig

Conical Plastic Cylinder Conical Temporary Cylinder 24p

ALIA EXternal Locking Abutment (Hex)

24p

25p

Fixture Lab Analog 23p

24p

ALIA EXternal Locking Lab Analog (Upper) (Lower) Conical Impression Coping (Pick-up)

Conical Impression Coping (Transfer) 25p 22p

Impression Plastic Cap Conical Healing Cap

22p

25p

Conical Abutment Screw 69p 22p

Conical Abutment (Estheticone, Midicone, Widecone, Widecone T-Type)

EXternal YK Transfer Adapter & Screw (EST)

67p

Repositioning Jig

67p

16p 16p 16p

0.9Hex Hand Driver

Cover Screw

Headless Cover Screw

Healing Abutment

1.2Hex Hand Driver

14p

Fixture(EST)

SHINSAEGI MEDI-TECH

21

EST System

08 Conical Abutment

- Screw retained restoration - Collar height : 1, 2, 3, 4mm - Length : Estheticone 1.8mm, Widecone 1.0mm and Midicone 1.0mm - Instrumentation required Estheticone & Midicone 2.0hex driver, Widecone 2.7hex driver - Packing unit : Included abutment screw (EAE Series + ESE001, EAM Series + ESM001, EAW Series + ESW001, TAW501 Series + TSW001, TAW Series + TSW002) - Torque recommendation : 30Ncm

Unit : mm

H G/H

Fixture Platform

D

Diameter (D)

Estheticone Midicone Widecone Widecone T-Type

Conical Abutment Screw

4.8 4.8 5.5 5.0 6.5

1.8 1.0 1.0 1.0 1.3

EAM403

EAM404

EAW501

EAW502

EAW503

EAW504

TAW501

TAW502

TAW503

TAW504

TAW601

TAW602

TAW603

TAW604

Unit : mm

Code ESE001 ESM001 ESW001 TSW001 TSW002

Unit : mm

Diameter (D)

Code

5.5 5.5 6.2 5.0 6.5

Estheticone Widecone

ECE001 ECM001 ECW001 TCW001 TCW002

- Gold alloy - Packing unit : Included cylinder screw (Estheticone + ESYTE41(ESYGE41), Midicone + ESYTM41(ESYGM41), Widecone + ESYTW51(ESYGW51), Widecone(T) +TSYIW50(TSYGW50)) - Torque recommendation : 20Ncm Unit : mm

Ti

Fixture Platform Estheticone

Non-Hex D

Midicone Widecone Widecone T-Type

22

EAM402

- Instrumentation required 1.2hex driver - Torque recommendation : 20Ncm

Widecone T-Type

Hex

EAM401

2.0 2.0 2.7 2.0 2.0

Midicone

Gold

4 EAE404

Estheticone

Fixture Platform

Conical Gold Cylinder

3 EAE403

Hex

Widecone T-Type

D

2 EAE402

Fixture Platform

Widecone

H

1 EAE401

- Instrumentation required 1.2hex Torque driver

Midicone

Conical Healing Cap

G/H

Height (H)

SHINSAEGI MEDI-TECH

Diameter (D) 4.8 4.8 5.5 5.5

Type

Code

Hex

EAGE00H

Non-Hex

EAGE00N

Hex

EAGM00H

Non-Hex

EAGM00N

Hex

EAGW00H

Non-Hex

EAGW00N

Hex

TAGW00H

Non-Hex

TAGW00N

EST System Conical Plastic Cylinder

- Packing unit : Included cylinder screw (Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESTW51, Widecone(T) + TSYTW50) - Torque recommendation : 20Ncm

Unit : mm

Ti

Fixture Platform

Non-Hex

Hex

Diameter (D)

Estheticone

4.8

Midicone

4.8

Widecone

Type

5.5

D

Widecone T-Type

Conical Temporary Cylinder

Ti

Diameter (D)

Estheticone

4.8

Midicone

5.3

Widecone

6.0

Non-Hex

EAPM00N

Hex

EAPW00H

Non-Hex

EAPW00N

Hex

TAPW00H

Non-Hex

TAPW00N

Type

Code

Hex

ETE001H ETE001N ETM001H ETM001N ETW001H ETW001N TTW001H TTW001N TTW002H TTW002N

Hex Non-Hex Hex

6.0

Non-Hex Hex

6.5

Non-Hex

- Instrumentation required 1.2hex Torque driver Fixture Platform

Type

Estheticone Midicone Ti

Widecone

Unit : mm

Product

Ti

ESYTE41

Gold

ESYGE41

Ti

ESYTM41

Gold

ESYGM41

Ti

ESYTW51

Gold

ESYGW51

Ti

TSYTW50

Gold

TSYGW50

Fixture Platform

Type

Product

Estheticone (Regular)

Hex

EIPE00H

Non-Hex

EIPE00N

Midicone (Regular)

Hex

EIPM00H

Non-Hex

EIPM00N

Widecone (Wide)

Hex

EIPW00H

Non-Hex

EIPW00N

Widecone (Wide) T-Type

Hex

TIPW00H

Non-Hex

TIPW00N

Widecone T-Type

Hex

EAPM00H

Hex

Widecone T-Type

Conical Impression Coping(pick-up)

Hex

Non-Hex

D

Gold

EAPE00H EAPE00N

Non-Hex

Non-Hex

Conical Cylinder Screw

Hex Non-Hex

- Screw retained restoration - Packing unit : Included cylinder screw (Estheticone + ESYTE41, Midicone + ESYTM41, Widecone + ESYTW51, Widecone(T) + TSYTW50) - Torque recommendation : 20Ncm Unit : mm Fixture Platform

Hex

5.5

Code

- Packing unit : Included guide pin

Unit : mm

Non-Hex

SHINSAEGI MEDI-TECH

23

EST System Conical Guide Pin(pick-up)

- Instrument required 1.2hex driver Fixture Platform Estheticone

H

Midicone

Widecone

Widecone T-Type

Unit : mm

Height (H)

Product

8 13 15 8 13 15 8 13 15 8 13 15

ESGE080 ESGE130 ESGE150 ESGM080 ESGM130 ESGM150 ESGW080 ESGW130 ESGW150 TSGW080 TSGW130 TSGW150

Conical Impression Coping (Transfer)

Unit : mm

Fixture Platform 4.1 (Regular)

Type

Product

Estheticone

EITE00N

4.1 (Regular)

Midicone

EITM00N

5.1 (Wide) 5.0 (Wide) T-Type

Widecone

EITW00N

Widecone

TITW00N

Conical Lab Analog

Unit : mm

Fixture Platform

09 ALIA External Locking Abutment (Hex)

Type

Product

4.1 (Regular) 4.1 (Regular)

Estheticone

ELEH410

Midicone

ELEL410

5.1 (Wide)

Widecone

ELEL510

5.0 (Wide) T-Type 6.0 (Wide) T-Type

Widecone

TLEL500

Widecone

TLEL600

- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw - Packing unit : Included abutment screw (EALN Series + ESLN Series, EALR Series + ESLR Series, EALW Series + ESLW Series) ex) EALN401H + ESLN401 - Torque recommendation : 30Ncm Unit : mm

Fixture Platform 3.5 (Narrow) 4.1 (Regular) G/H

5.1 (Wide) Hex D

5.0 (Wide) 6.0 (Wide)

24

SHINSAEGI MEDI-TECH

Diameter (D) 4.0 5.0 6.0 6.0 7.0 8.0 6.0 7.0 6.0 7.0

Hex (H) 2.4 2.7 2.7 3.4 3.4 3.4 2.7 2.7 2.7 2.7

G/H 1

2

3

4

EALN401H EALN402H EALN403H EALN404H EALR501H EALR502H EALR503H EALR504H EALR601H EALR602H EALR603H EALR604H EALW601H EALW602H EALW603H EALW604H EALW701H EALW702H EALW703H EALW704H EALW801H EALW802H EALW803H EALW804H TALW601H TALW602H TALW603H TALW604H TALW701H TALW702H TALW703H TALW704H TALS601H TALS602H TALS603H TALS604H TALS701H TALS702H TALS703H TALS704H

EST System External Locking Abutment Screw

- Instrument required 1.2hex Torque driver or Positioning Jig Fixture Platform 3.5 (Narrow) 4.1 (Regular)

L

5.1 (Wide)

5.0 (Wide)

External YK Transfer Adapter

Unit : mm

Length(L) 8

9

10

11

ESLN401

ESLN402

ESLN403

ESLN404

ESLR501

ESLR502

ESLR503

ESLR504

ESLR601

ESLR602

ESLR603

ESLR604

ESLW601

ESLW602

ESLW603

ESLW604

ESLW701

ESLW702

ESLW703

ESLW704

ESLW801

ESLW802

ESLW803

ESLW804

TSLW601

TSLW602

TSLW603

TSLW604

TSLW701

TSLW702

TSLW703

TSLW704

- Packing unit : Included External YK Transfer screw - Torque recommendation : 15Ncm Fixture Platform Diameter (D)

Hex

3.5

4.0

2.4

4.1

5.0

2.7

5.1

6.0

3.4

5.0

6.0

2.7

G/H

Hex

Unit : mm

G/H

Code

1.5 3.5 1.5 3.5 1.5 3.5 1.5 3.5

ETLN150 ETLN350 ETLR150 ETLR350 ETLW150 ETLW350 TTLW150 TTLW350

D

External YK Transfer Screw

- Instrument required 1.2hex Torque driver or Positioning Jig Fixture Platform

Diameter (D)

3.5

3.36

4.1

3.86

L

4.86

5.1

4.86

5.0

Unit : mm

Length (L)

Code

9 11 9 11 9 11 9 11

ESTLN35S ESTLN35L ESTLR41S ESTLR41L ESTLW51S ESTLW51L TSTLW50S TSTLW50L

Impression Plastic Cap

Unit : mm

Code SIYC 600

External Locking Lab Analog

- Packing unit : Included Upper+Lower Fixture Platform 3.5 4.1 5.1

(Upper)

(Lower)

Unit : mm

Type

Code

Upper

ELLN001

Lower

ELLN002

Upper

ELLR001

Lower

ELLR002

Upper

ELLW001

Lower

ELLW002

5.0

Upper

TLLW001

T-Type

Lower

TLLW002

6.0

Upper

TLLS001

T-Type

Lower

TLLS002 SHINSAEGI MEDI-TECH

25

Prosthetic Flow Diagrams For EST System Overdenture Retained Restoration for O-Ring Abutment

27p

27p

For Denture O-Ring (Red)

For laboratory O-Ring (Black)

27p

O-Ring Retainer

27p

O-Ring Lab Analog

27p 68p

O-Ring Abutment

O-Ring Abutment Driver (2.4 Hex)

67p

67p

16p 16p 16p

0.9Hex Hand Driver

Cover Screw

Headless Cover Screw

14p

Fixture(EST)

26

SHINSAEGI MEDI-TECH

Healing Abutment

1.2Hex Hand Driver

EST System

10 O-Ring Abutment G/H

- Overdenture restoration - Multiple implant bone retained and fixed removable overdentures - Seating surface diameter 4.1mm - Collar height : 2, 3, 4, 5, 6mm - Instrument required O-Ring Abutment Driver(2.4hex) - Packing unit : Included O-Ring 2ea and O-Ring Retainer 1ea

Unit : mm

D

2.0

3.0

G/H 4.0

EARR200

EARR300

EARR400

Fixture DiamPlatform eter(D) 4.1 (Regular)

5.0

5.0

6.0

EARR500

EARR600

O-Ring

O-Ring Retainer

Unit : mm

Type

Code

Red(Denture)

IARR002

Black(Laboratory)

IARR003

- Female receptacle processed into denture

Unit : mm

Code IARR001

O-Ring Lab Analog

Unit : mm

Code RL001

SHINSAEGI MEDI-TECH

27

28

SHINSAEGI MEDI-TECH

Submerged Fixture Esthetic & Innovation

SHINSAEGI MEDI-TECH SHINSAEGI MEDI-TECH

29

SST System

01 02

03 04 05

06

07

30

Sub-Cover Screw Sub-Healing Abutment Sub-Solid Abutment Sub-Solid Impression Coping Sub-Solid plastic Coping Sub-Solid Healing Cap Sub-Solid Lab Analog Sub-Cemented Abutment Sub-Cemented Abutment Screw ALIPS Locking Abutment Screw Sub-Angled Abutment Sub-Temporary Abutment Sub-Impression Coping (Pick-up) Sub-Impression Coping Guide Pin (Pick-up) Sub-Impression Coping Guide Pin (Transfer) Sub-Impression Coping (Transfer) Sub-Gold Abutment Sub-Fixture Lab Analog ALIA Sub-Locking Abutment (Hex) Sub-Locking Abutment Screw Sub-YK Transfer Adapter Sub-YK Transfer Screw Sub-Locking Fixture Lab Analog Sub-O-Ring Abutment Sub-O-Ring Sub-Retainer Sub-O-Ring Lab Analog

SHINSAEGI MEDI-TECH

34p 34p 34p 35p 35p 35p 35p 37p 37p 37p 37p 37p 38p 38p 38p 38p 38p 38p 40p 40p 40p 40p 40p 42p 42p 42p 42p

- SST implant components and ASTRA implant components are fully interchangeable.

The inner of head

Flapless surgery - Head design is the same diameter as the implant body - This implant ideal for surgery No counter sinking - This makes the surgical procedure faster and simple.

Micro groove

Apex Body design

Slightly taper -This design for increased initial stablity in soft bone Unique grooves -Increase stability compared to "v"type thread implant

SHINSAEGI MEDI-TECH

INTERNAL (IST.IT)

Sharp tip on 3-cutting edge -This sharp tip also secures a smooth insertion without the implant wobbling -Implant will not spin and loss stablity when a higher density area in reached -This thread design make the implant a very efficient selftapping unit.

INTERNAL (IST.IT)

- Acheive both soft and hard tissue attachement - Generate strong attachment of cortical bone - Superior primary stability

SUBMERGED (SST)

Internal Hex connection

Body of head

EXTERNAL (EST)

Submerged Slightly Tapered Fixture (SST System)

31

Submerged Slightly Tapered Fixture (SST System) Feature

- Submerged Internal Hex connection - Hex : 2.5mm - Apex size : Narrow( 2.25mm), Regular( 2.9mm), Wide( 3.6mm), Wide6.0( 4.3mm) - Torque recommendation : 40Ncm

Narrow

SST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

3.8

L

Head Diameter (D1)

3.8

Body Diameter (D2)

3.75

Hex (H)

2.5

Hex

Length (L)

Code

9

SFSN309

11

SFSN311

13

SFSN313

15

SFSN315

D2

Regular

SST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

L

4.3

Head Diameter (D1)

4.3

Body Diameter (D2)

4.2

Hex (H)

2.5

Hex

Length (L)

Code

7

SFSR407

9

SFSR409

11

SFSR411

13

SFSR413

15

SFSR415

D2

Wide

SST System

Unit : mm

Platform Diameter (D0)

D1 ||

D0

L

5.0

Head Diameter (D1)

5.0

Body Diameter (D2)

4.9

Hex (H)

2.5

Hex

Length (L)

Code

7

SFSW507

9

SFSW509

11

SFSW511

13

SFSW513

15

SFSW515

D2

Wide6.0

SST System Platform Diameter (D0)

D1 D0

5.0

L

Hex D2

32

Unit : mm

SHINSAEGI MEDI-TECH

Head Diameter (D1)

6.0

Body Diameter (D2)

5.9

Hex (H)

2.5

Length (L)

Code

7

SFSW607

9

SFSW609

11

SFSW611

13

SFSW613

Prosthetic Flow Diagrams For SST System Cement Retained restoration for Sub-Solid Abutment

35p

(Single) (Bridge) Sub-Solid Plastic Coping

35p

Sub-Solid Lab Analog

34p

Sub-Solid Impression Coping

35p

Sub-Solid Healing Cap

68p 34p

1.2Hex Torque Driver

Sub-Solid Abutment ( 4.5, 5.5, 6.5)

67p

34p

34p

Sub-Cover Screw

Sub-Healing Abutment

1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH

33

SST System

01 Sub-Cover Screw

- Head height : 0.5, 1.5mm - Instrumentation required 1.2hex hand driver - Torque recommendation : 5˜8Ncm Platform Diameter(D)

Code

0.5

SSV001

1.5

SSV002

3.8 4.3 5.0 6.0

Sub-Healing Abutment

- Instrumentation required 1.2hex driver - Torque recommendation : 5˜8Ncm Fixture DiamPlatform eter(D)

2

G/H

3.8 (Narrow)

D

4.3 (Regular)

5.0 6.0

(Wide)

02 Sub-Solid Abutment 4

5.5 G/H

D

4.5 SHAN4515

2.0

2.5

-

SHAN4525

-

4.5

5.0

5.5

-

SHAN4555

SHAN4535 SHAN4545

SHAR5020 SHAR5030 SHAR5050 5.0 SHAR5525 SHAR5535 SHAR5545 SHAR5555 5.5 SHAR5515 SHAW6525 SHAW6535 SHAW6545 SHAW6555 6.5 SHAW6515 SHAW7525 SHAW7535 SHAW7545 SHAW7555 7.5 SHAW7515

Unit : mm

Fixture Platform 3.8 4.3 (Regular)

5.0 6.0

(Wide)

SHINSAEGI MEDI-TECH

1.5

Unit : mm

Code 3.0 3.5

- Cement retained restoration - Height is 5.5mm with marked groove 4mm for easy cutting - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm and specially SASN series height 1.0, 1.5, 2.5, 3.5, 4.5mm - Profile diameter : 4.5, 5.5, 6.5mm - Instrument required 1.2hex driver - Torque recommendation : 30Ncm

(Narrow)

34

Unit : mm

Height (H)

Diameter(D) 4.5

Code 1.0

1.5

2.5

3.5

4.5

SASN4510 SASN4515 SASN4525 SASN4535 SASN4545

5.5 -

5.5

-

SASR5515 SASR5525 SASR5535 SASR5545 SASR5555

6.5

-

SASW6515 SASW6525 SASW6535 SASW6545 SASW6555

SST System Sub-Solid Impression Coping

Unit : mm

Diameter (D)

Code

4.5

SISC45L

5.5

SISC55L

6.5

SISC65L

Sub-Solid plastic Coping

Unit : mm

Diameter (D) 4.5 5.5 Single

6.5

Bridge

Type

Code

Single

SISP45S

Bridge

SISP45B

Single

SISP55S

Bridge

SISP55B

Single

SISP65S

Bridge

SISP65B

Sub-Solid Healing Cap

Unit : mm

Diameter (D)

D

Code

4.5 5.5

SHS45L

6.5

SHS65L

SHS55L

Sub-Solid Lab Analog

Unit : mm

Diameter (D) H

4.5 5.5

Short

Long

6.5

Height (H)

Code

4.0 5.5 4.0 5.5 4.0 5.5

SLSN45S SLSN45L SLSR55S SLSR55L SLSW65S SLSW65L

SHINSAEGI MEDI-TECH

35

Prosthetic Flow Diagrams For SST System Screw & Cement Retained restoration for Sub-Cement Abutment, Sub-Angled Abutment, Sub-Temporary Abutment, Sub-Gold Abutment

68p 69p

37p 37p

ALIPS Driver

ALIPS Locking Screw

Sub-Abutment Screw

37p

1.2Hex Torque Driver

(Hex) (Non Hex) Sub-Cemented Abutment

(Hex) (Non Hex) Sub-Angled Abutment

38p

37p

37p

(Hex) (Non Hex) Sub-Temporary Abutment

(Hex) (Non Hex) Sub-Gold Abutment

38p

Sub-Fixture Lab Analog

38p

38p

(Hex) (Non Hex) Sub-Impression Coping (Pick-up)

(Hex) (Non Hex) Sub-Impression Coping (Transfer)

67p

34p

34p

Sub-Cover Screw

Sub-Healing Abutment

32p

Fixture(SST)

36

SHINSAEGI MEDI-TECH

1.2Hex Hand Driver

SST System

03 Sub-Cemented Abutment

- Cement retained restoration - Collar height : 1.5, 2.5, 3.5, 4.5, 5.5mm - Specially SACN series height : 1.0, 2.5, 3.5, 4.5mm - Packing unit : Included abutment screw(SSA001) - Profile diameter : 4.5, 5.5, 6.5mm - Length is 7mm with marked microgroove 4.0mm and 5.5mm for easy cutting - Torque recommendation : 30Ncm

Unit : mm

5.5

4

7

L

Fixture Diam- Length Type Platform eter(D) (L)

G/H

5.5 3.8

D Hex

(Narrow)

4.5 7.0

Non-Hex

5.5 4.3 (Regular)

5.5 7.0

5.0

5.5

(Wide)

6.5 6.0

7.0

(Wide)

Sub-Cemented Abutment Screw

G/H 1.0

1.5

2.5

3.5

4.5

5.5

SAC4510H

SAC4515H

SAC4525H

SAC4535H

SAC4545H

-

Non-Hex SAC4510N

SAC4515N

SAC4525N

SAC4535N

SAC4545N

-

SACN4510H SACN4515H SACN4525H SACN4535H SACN4545H

-

Hex Hex

Non-Hex SACN4510N SACN4515N SACN4525N SACN4535N SACN4545N

-

SAC5515H

SAC5525H

SAC5535H

SAC5545H

SAC5555H

-

SAC5515N

SAC5525N

SAC5535N

SAC5545N

SAC5555N

-

SACR5515H SACR5525H SACR5535H SACR5545H SACR5555H

Non-Hex

-

SACR5515N SACR5525N SACR5535N SACR5545N SACR5555N

Hex

-

SAC6515H

SAC6525H

SAC6535H

SAC6545H

SAC6555H

Non-Hex

-

SAC6515N

SAC6525N

SAC6535N

SAC6545N

SAC6555N

Hex

-

SACW6515H SACW6525H SACW6535H SACW6545H SACW6555H

Non-Hex

-

SACW6515N SACW6525N SACW6535N SACW6545N SACW6555N

Hex

-

Non-Hex Hex

- Instrumentation required 1.2hex Torque driver

Unit : mm

Code SSA001

ALIPS Locking Abutment Screw

- For use In-octa cemented abutment - ALIPS(Anti Lock Inner Post Screw) - Instrumentation required ALIPS driver Unit : mm Diameter (D)

Code

3.8 4.3

ISAP001

5.0 6.0

04 Sub-Angled Abutment 7 G/H

D

Hex

- Cement retained restorations - Angulation : 15 , 25 - Collar height : 2mm, 4mm - Packing unit : Included abutment screw (SSA001) Fixture Platform 3.8 (Narrow) 4.3 (Regular)

Diameter (D) 4.5 5.5

Unit : mm

G/H

Angle ( ) 15 25 15 25

2.0

4.0

SAAN4152H (N)

SAAN4154H (N)

SAAN4252H (N)

SAAN4254H (N)

SAAR5152H (N)

SAAR5154H (N)

SAAR5252H (N)

SAAR5254H (N)

Non-Hex

05 Sub-Temporary Abutment

- Packing unit : Included Abutment Screw(SSA001) - Torque recommendation : 30Ncm G/H

G/H

Hex

Non-Hex D

1.0 3.0

Type

Unit : mm

4.5

Hex

STAN4510H

Non-Hex

STAN4510N

Hex

STAN4530H

Non-Hex

STAN4530N

SHINSAEGI MEDI-TECH

37

SST System Sub-Impression Coping (Pick-up)

- Packing unit : Included Guide Pin Fixture Platform

Diameter (D) Hex

4.5 Non-Hex Hex H

5.5 Non-Hex

Hex

Non-Hex

Hex

D

6.5 Non-Hex

Unit : mm

Length (L)

Code

Short14

SIPN45HS

Long18

SIPN45HL

Short14

SIPN45NS

Long18

SIPN45NL

Short14

SIPR55HS

Long18

SIPR55HL

Short14

SIPR55NS

Long18

SIPR55NL

Short14

SIPW65HS

Long18

SIPW65HL

Short14

SIPW65NS

Long18

SIPW65NL

Sub-Impression Coping Guide Pin (Pick-up)

Unit : mm

Height (H)

Code

Short

SSGP00S

Long

SSGP00L

Sub-Impression Coping (Transfer)

Unit : mm

Fixture Platform

Diameter (D) Hex

4.5 Non-Hex Hex

5.5

L

Non-Hex Hex

Non-Hex

Hex

D

6.5 Non-Hex

Length (L)

Code

Short10

SITN45HS

Long14

SITN45HL

Short10

SITN45NS

Long14

SITN45NL

Short10

SITR55HS

Long14

SITR55HL

Short10

SITR55NS

Long14

SITR55NL

Short10

SITW65HS

Long14

SITW65HL

Short10

SITW65NS

Long14

SITW65NL

Sub-Impression Coping Guide Pin (Transfer)

Sub-Gold Abutment

Unit : mm

Hex

1.0

Non-Hex D

Code

Short

SSGT00S

Long

SSGT00L

- Packing unit : Included Abutment Screw(SSA001) - Torque recommendation : 30Ncm G/H

G/H

Height (H)

3.0

Type

4.5

5.5

SAGN4510H

SAGN5510H

SAGN6510H

Non-Hex

SAGN4510N

SAGN5510N

SAGN6510N

Hex

SAGN4530H

SAGN5530H

SAGN6530H

Non-Hex

SAGN4530N

SAGN5530N

SAGN6530N

Unit : mm

Code SLFR001

SHINSAEGI MEDI-TECH

6.5

Hex

Sub-Fixture Lab Analog

38

Unit : mm

Prosthetic Flow Diagrams For SST System Cement & Screw Retained Restoration Component for Sub-Locking Abutment, Sub-Locking Temporary Abutment

68p 40p

1.2Hex Torque Driver

69p

ALIA Sub-Locking Abutment Screw

Repositioning Jig

40p

ALIA Sub-Locking Abutment

40p

ALIA Sub-Locking Lab Analog (Upper) (Lower)

40p

Impression Plastic Cap

69p

40p

Sub-YK Transfer Adapter & Screw (SST)

Repositioning Jig 67p

34p

34p

Sub-Cover Screw

Sub-Healing Abutment

1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH

39

SST System

06 ALIA Sub-Locking Abutment (Hex)

- Screw retained restoration - Hexagon base for anti-rotating locking with a locking abutment screw - Packing unit : Included abutment screw (SALN Series + SSLN Series, SALR Series + SSLR Series, SALW Series + SSLW Series) - Torque required 30Ncm

Unit : mm

Fixture Platform G/H

D

Sub-Locking Abutment Screw

Diameter (D)

3.8 (Narrow) 4.3 (Regular)

4.5 5.5

5.0 (Wide) 6.0 (Wide)

6.5

1

G/H 2.5

1.5

3.5

4.5

SALN4510H SALN4515H SALN4525H SALN4535H SALN4545H

-

SALR5515H SALR5525H SALR5535H SALR5545H

-

SALW6515H SALW6525H SALW6535H SALW6545H

- Instrumentation required 1.2Hex Torque driver or reposintiong Jig Unit : mm

8

9

Length(L) 10

3.8 (Narrow)

SSLN4510

SSLN4515

SSLN4525

SSLN4535

SSLN4545

4.3 (Regular) 5.0 (Wide)

-

SSLR5515

SSLR5525

SSLR5535

SSLR5545

-

SSLW6515

SSLW6525

SSLW6535

SSLW6545

Fixture Platform L

6.0 (Wide)

11

12

Impression Plastic Cap

Unit : mm

Code SIYC 600

Sub-YK Transfer Adapter G/H

Sub-YK Transfer Adapter Screw H

Unit : mm

G/H

Code

1.5 3.5

STAL150 STAL350

- Instrumentation required 1.2Hex driver or reposintiong Jig Height(H)

Code

9

SSTL090

11

SSTL110

Sub-Locking Fixture Lab Analog

(Upper)

40

(Lower)

SHINSAEGI MEDI-TECH

Unit : mm

Unit : mm

Type

Code

Upper

SLLR001

Lower

SLLR002

Prosthetic Flow Diagrams For SST System Overdenture Retained Restoration for O-Ring Abutment

42p

42p

For Denture O-Ring

For Laboratory O-Ring

42p

Retainer

42p

Sub-O-Ring Lab Analog

68p

42p

O-Ring Abutment Driver (2.4Hex)

Sub-O-Ring Abutment

67p

34p

34p

Sub-Cover Screw

Sub-Healing Abutment

1.2Hex Hand Driver

32p

Fixture(SST)

SHINSAEGI MEDI-TECH

41

SST System

07 Sub-O-Ring Abutment G/H

- Overdenture restoration - Multiple implant bone retained and fixed removable overdenture - Collar height : 1, 2, 3, 4mm - Instrument required : O-Ring abutment driver(2.4Hex) - Packing unit : Included O-Ring 2ea, Sub-retainer 1ea - Torque recommendation : 30Ncm

Unit : mm

D

Diameter (D) 4.5 5.5

G/H 1.0

2.0

3.0

4.0

SARN4510

SARN4520

SARN4530

SARN4540

SARR5510

SARR5520

SARR5530

SARR5540

Sub-O-Ring

Sub-Retainer

Unit : mm

Type

Code

Red(Denture) Black(Laboratory)

IARR002 IARR003

- Female receptacle processed into denture

Unit : mm

Code IARR001

Sub-O-Ring Lab Analog

Unit : mm

Code RL001

42

SHINSAEGI MEDI-TECH

Internal Fixture Esthetic & Innovation

SHINSAEGI MEDI-TECH SHINSAEGI MEDI-TECH

43

44

SHINSAEGI MEDI-TECH

- IST Implant components and ITI, SWISS PLUS IMPLANT components are fully interchaneable.

The inner of head

Machined finished collar of 1.8mm

Micro groove under of head

Apex Body design

Slightly taper -This design for increased initial stablity in soft bone Unique grooves -Increase stability compared to "v"type thread implant

SHINSAEGI MEDI-TECH

INTERNAL (IST.IT)

Sharp tip on 3-cutting edge -This sharp tip also secures a smooth insertion without the implant wobbling -Implant will not spin and loss stablity when a higher density area in reached -This thread design make the implant a very efficient selftapping unit.

INTERNAL (IST.IT)

Positive anchor as osseointegration occus Acheive both soft and hard tissue attachment Superior primary stability

SUBMERGED (SST)

Internal octa connection

Body of head Esthetic collar

EXTERNAL (EST)

Internal Slightly Tapered Fixture (IST System)

45

Internal Slightly Tapered Fixture (IST System) Feature

- Internal octa connection - Collar height is fixed 1.8mm - Apex size : Regular( 2.4mm), Wide( 2.6mm), Wide6.0( 4.0mm) - Torque recommendation : 40Ncm

Regular

IST System Unit : mm

D1 ||

D0

1.8

O

Platform Diameter (D0)

Head Diameter (D1)

Body Diameter (D2)

Octa (O)

L

4.8

4.8

4.1

3.1

D2

Wide

Length (L)

Code

7

IFSR407

9

IFSR409

11

IFSR411

13

IFSR413

15

IFSR415

IST System Unit : mm

D1 ||

D0

1.8

O

Platform Diameter (D0)

Head Diameter (D1)

Body Diameter (D2)

Octa (O)

L

4.8

4.8

4.8

3.1

D2

Wide6.0

Length (L)

Code

7

IFSW507

9

IFSW509

11

IFSW511

13

IFSW513

15

IFSW515

IST System Unit : mm

D1 ||

D0 1.8

L

46

SHINSAEGI MEDI-TECH

O

Platform Diameter (D0)

6.0

Head Diameter (D1)

6.0

Body Diameter (D2)

5.3

Octa (O)

3.1

Length (L)

Code

7

IFSW607

9

IFSW609

11

IFSW611

13

IFSW613

Internal Fixture Esthetic & Innovation

SHINSAEGI MEDI-TECH SHINSAEGI MEDI-TECH

47

IT & IST System

01 02

03

04 05

06

07

48

Cover Screw Headless Cover Screw Healing Abutment Solid Abutment Solid Healing Cap Solid Impression Coping Solid Positioning Cylinder Solid Impression Cap Solid Impression Shoulder Analog Solid Impression Shoulder Analog Pin Solid Plastic Coping Solid Lab Analog Excellent Solid Abutment Excellent Solid Healing Cap Excellent Solid Impression Coping Excellent Solid Positioning Cylinder Excellent Solid Impression Cap Excellent Solid Impression Shoulder Analog Excellent Solid Impression Shoulder Analog Pin Excellent Solid Plastic Coping Excellent Solid Lab Analog Solid Angled Abutment Solid Angled Abutment Screw In-Octa Cemented Abutment In-Octa Cemented Abutment Screw ALIPS Locking Abutment Screw In-Octa Locking Abutment (Octa) In-Octa Locking Abutment Screw In-Octa YK Transfer Adapter In-Octa YK Transfer Adapter Screw In-Octa Locking Lab Analog In-Octa Gold Abutment In-Octa Impression Coping (pick-up) In-Octa Guide Pin(pick-up) In-Octa Impression Coping (Transfer) In-Octa Guide Pin(Transfer) In-Octa Lab Analog Octa Abutment Octa Abutment Healing Cap Octa Gold Cylinder Octa Plastic Cylinder Octa Abutment and Cylinder Screw Octa Impression Coping (pick-up) Guide Pin (pick-up) Octa Lab Analog O-Ring Abutment O-Ring O-Ring Retainer O-Ring Lab Analog

SHINSAEGI MEDI-TECH

52p 52p 52p 52p 52p 53p 53p 53p 53p 53p 53p 54p 54p 54p 54p 54p 55p 55p 55p 55p 55p 57p 57p 57p 57p 57p 58p 58p 58p 58p 58p 59p 59p 59p 59p 59p 59p 61p 61p 61p 61p 62p 62p 62p 62p 64p 64p 64p 64p

- IT implant components and ITI, SWISS PLUS implant components are fully interchangeable.

The inner of head

Machined finished collar of 1.8mm

Micro groove under of head

Body design

Apex

- This innovation design is a selftapping tapered implant that provides lateral compression of the osteotomy site to greatly improve primary stability - This tapered design make the implant a very efficient selftapping unit

SHINSAEGI MEDI-TECH

INTERNAL (IST.IT)

This design have a tapered shape similar to roots form requining less bone removal and less bone augmentation to till the extraction socket

INTERNAL (IST.IT)

Positive anchor as osseointegration occus Acheive both soft and hard tissue attachment Superior primary stability

SUBMERGED (SST)

Internal octa connection

Body of head Esthetic collar

EXTERNAL (EST)

Internal Tapered Fixture (IT System)

49

Internal Tapered Fixture (IT System) Feature

- Internal octa connection - Collar height is fixed 1.8mm - Apex size : Regular( 2.4mm), Wide( 3.1mm), Wide6.0( 3.6mm) - Torque recommendation : 40Ncm

Regular

IT System Unit : mm

D1 ||

D0

1.8

O

Platform Diameter (D0)

Head Diameter (D1)

Body Diameter (D2)

Octa (O)

L

4.8

4.8

4.1

3.1

D2

Wide

Length (L)

Code

7

IFTR407

9

IFTR409

11

IFTR411

13

IFTR413

15

IFTR415

IT System Unit : mm

D1 ||

D0

1.8

O

Platform Diameter (D0)

Head Diameter (D1)

Body Diameter (D2)

Octa (O)

L

4.8

4.8

4.8

3.1

D2

Wide6.0

Length (L)

Code

7

IFTW507

9

IFTW509

11

IFTW511

13

IFTW513

15

IFTW515

IT System Unit : mm

D1 ||

D0

1.8

L

D2

50

SHINSAEGI MEDI-TECH

O

Platform Diameter (D0)

6.0

Head Diameter (D1)

6.0

Body Diameter (D2)

5.3

Octa (O)

3.1

Length (L)

Code

7

IFTW607

9

IFTW609

11

IFTW611

13

IFTW613

Prosthetic Flow Diagrams For IST And IT System Cement Retained restoration for Solid Abutment, Excellent Solid Abutment

53p, 55p

Single(Red) Bridge(White) Solid Plastic Coping Excellent Solid Plastic Coping

54p

55p

Solid Lab Analog Excellent Solid Lab Analog

53p,55p

Solid Positioning Cylinder Excellent Solid Positioning Cylinder

53p,55p

53p,55p

Solid shoulder Analog Excellent Solid shoulder Analog

Solid shoulder Analog Pin Excellent Solid shoulder Analog Pin

53p,55p

Solid Impression Cap Excellent Solid Impression Cap

52p,54p 68p 52p,54p

Solid Healing Cap Excellent Solid Healing Cap

Solid Abutment Excellent Solid Abutment

Solid Driver Excellent Solid Driver 67p

52p

52p

Cover Screw

Headless Cover Screw

46p

Internal Slightly Fixture(IST)

52p

Healing Abutment

1.2Hex Hand Driver

50p

Internal Tapered Fixture(IT)

SHINSAEGI MEDI-TECH

51

IST & IT System

01 Cover Screw

- Head height : 1.3mm - Instrumentation required 1.2Hex hand driver - Torque recommendation : 5˜8Ncm

Unit : mm

Platform Diameter (mm)

Code

4.8 6.0

Headless Cover Screw

ISV400 ISV600

- Instrumentation required 1.2Hex hand driver - Torque recommendation : 5˜8Ncm

Unit : mm

Platform Diameter (mm)

Code

4.8 6.0

Healing Abutment

ISH400

- Profile diameter : 4.8, 5.5, 6.0, 7.0mm - Head height : 2, 3, 4mm - Instrumentation required 1.2hex hand driver - Torque recommendation : 5˜8Ncm

G/H

Platform Diameter(mm)

Diameter (D)

D

4.8 5.5 6.0 7.0

4.8 6.0

02 Solid Abutment L

Unit : mm

2

G/H 3

4

IHA420

IHA430

IHA440

IHA520

IHA530

IHA540

IHA620

IHA630

IHA640

IHA720

IHA730

IHA740

- It is available in three heights to accommodate vertical requirements (4.0, 5.5, 7.0mm) - For use in single tooth or multiple unit restoration - Packing unit : Included solid healing cap - Instrumentation required Solid driver - Torque recommendation : 30Ncm

Unit : mm

Platform Diameter(mm) 4.8

Solid Healing Cap

D

52

SHINSAEGI MEDI-TECH

4.0

Length (L) 5.5

7.0

IAS440

IAS455

IAS470

- For use protect for solid abutment

Unit : mm

Height (H)

Product

4 5.5 7

IHSC440 IHSC455 IHSC470

IST & IT System Solid Impression Coping

- Solid positioning cylinder + Solid impression cap = Solid impression coping Unit : mm

Height (H)

Code

4 5.5 7

IISI 440 IISI 455 IISI 470

Solid Positioning Cylinder

Unit : mm

Platform Diameter(mm) 4.8

6.0

Height (H)

Code

4 5.5 7 4 5.5 7

IISY440 IISY455 IISY470 IISY640 IISY655 IISY670

Solid Impression Cap

Unit : mm

Platform

Code

4.8 6.0

IISC480 IISC600

D

Solid Impression Shoulder Analog

Unit : mm

Platform

Code

4.8 6.0

IISL480 IISL600

Solid Impression Shoulder Analog Pin

Unit : mm

Platform

Code

4.8 6.0

IISN480 IISN600

Solid Plastic Coping

Unit : mm

Platform Diameter(mm) 4.8 6.0

Color

Code

Single(Red) Bridge(White) Single(Red) Bridge(White)

IISP48S IISP48B IISP60S IISP60B

SHINSAEGI MEDI-TECH

53

IST & IT System Solid Lab Analog H

Unit : mm

Platform Diameter(D) 4.8 6.0

4.0

Height (H) 5.5

7.0

ILS440

ILS455

ILS470

ILS640

ILS655

ILS670

D

03 Excellent Solid Abutment L

- It is available in three height to accommodate vertical requirements (4.0, 5.5, 7.0mm) - Instrumentation required 4.8 : Excellent solid driver and 6.0 : 1.2Hex driver - Packing unit : Included excellent solid healing cap - Torque recommendation : 30Ncm

Unit : mm

Platform Diameter 4.8 6.0

Excellent Solid Healing Cap

Excellent Solid Impression Coping

7.0

IAX440

IAX455

IAX470

IAX640

IAX655

IAX670

- For use protect for excellent solid abutment Platform Diameter

H

4.0

Length (L) 5.5

4.8 6.0

Unit : mm

4.0

Height (H) 5.5

7.0

IHXC440

IHXC455

IHXC470

IHXC640

IHXC655

IHXC670

- Excellent Solid positioning cylinder + Solid impression cap = Solid impression coping Unit : mm

Platform Diameter H

4.8 6.0

4.0

Height (H) 5.5

7.0

IIXI 440

IIXI 455

IIXI 470

IIXI 640

IIXI 655

IIXI 670

4.0

Height (H) 5.5

7.0

IIXY440

IIXY455

IIXY470

IIXY640

IIXY655

IIXY670

Excellent Solid Positioning Cylinder

Unit : mm

Platform Diameter H

54

SHINSAEGI MEDI-TECH

4.8 6.0

IST & IT System Excellent Solid Impression Cap

Unit : mm

Platform Diameter(D)

Code

4.8 6.0

IIXC480 IIXC600

D

Excellent Solid Impression Shoulder Analog

Unit : mm

Platform Diameter(D)

Code

4.8 6.0

IIXL480 IIXL600

D

Excellent Solid Impression Shoulder Analog Pin

Unit : mm

Platform Diameter(D)

Code

4.8 6.0

IIXN480 IIXN600

Excellent Solid Plastic Coping

Unit : mm

Platform Diameter 4.8 Single

Bridge

6.0

Color

Code

Single(Red)

IIXP48S

Bridge(White)

IIXP48B

Single(Red)

IIXP60S

Bridge(White)

IIXP60B

Excellent Solid Lab Analog H

Unit : mm

Platform Diameter(D) 4.8 6.0

4.0

Height (H) 5.5

7.0

ILX440

ILX455

ILX470

ILX640

ILX655

ILX670

D

SHINSAEGI MEDI-TECH

55

Prosthetic Flow Diagrams For IST And IT System Cement and Screw Retained restoration for In-Octa Cemented Abutment, In-Octa Gold Abutment, Solid Angled Abutment, In-Octa Locking Abutment.

68p

58p

57p

69p

57p

ALIPS Driver

ALIPS Locking Screw

In-Octa Cemented Abutment Screw

ALIA In-Octa Locking Abutment Screw

1.2Hex Torque Driver

58p

ALIA In-Octa Locking Abutment

59p 57p

57p

58p

In-Octa Cement Abutment (Octa, Non-Octa)

In-Octa Gold Abutment (Octa, Non-Octa)

Solid Angled Abutment (Octa) ALIA In-Octa Locking Lab Analog (Upper) (Lower)

59p 58p

In-Octa Lab Analog

Impression Plastic Cap

58p

57p

69p

In-Octa Impression Coping (Pick-up)

In-Octa YK Transfer Adapter & Screw (IST&IT)

Repositioning Jig

67p

52p

52p

Cover Screw

Headless Cover Screw

46p

Internal Slightly Fixture(IST)

56

SHINSAEGI MEDI-TECH

52p

Healing Abutment

50p

Internal Tapered Fixture(IT)

1.2Hex Hand Driver

IST & IT System

04 Solid Angled Abutment 7

- Cement retained restoration - Angulation : 15 , 25 - Packing unit : Included abutment screw(ISAT001) - Torque recommendation : 30Ncm Angle(

)

Code IAA150

15 25

Solid Angled Abutment Screw

Unit : mm

IAA250

-Instrumentation required 1.2hex driver

Unit : mm

Code ISAT001

05 In-Octa Cemented Abutment 4

5.5

7

- Cement retained restorations - Collar height : 0, 1, 2, 3, 4mm - For use in single tooth or multiple unit restoration - Packing unit : Included abutment screw (ISCT001) - Torque recommendation : 30Ncm Fixture Platform (D) 4.8

Non-Octa

Octa D

In-Octa Cemented Abutment Screw

6.0

Type

0

1.0

G/H 2.0

3.0

Unit : mm

4.0

Octa

IAC407O

IAC417O

IAC427O

IAC437O

IAC447O

Non-Octa

IAC407N

IAC417N

IAC427N

IAC437N

IAC447N

Octa

IAC607O

IAC617O

IAC627O

IAC637O

IAC647O

Non-Octa

IAC607N

IAC617N

IAC627N

IAC637N

IAC647N

- Instrumentation required 1.2hex driver

Unit : mm

Code ISCT001

ALIPS Locking Abutment Screw

- For use In-octa cemented abutment - ALIPS(Anti Lock Inner Post Screw) - Instrumentation required ALIPS driver Platform 4.8 6.0

Unit : mm

Code ISAP001

SHINSAEGI MEDI-TECH

57

IST & IT System In-Octa Locking Abutment (Octa)

- Screw retained restoration - Octagone base for antirotation locking with a locking abutment screw - Packing unit : IALR Series + SSLR Series, IALW Series + SSLW Series - Torque required : 30Ncm

Unit : mm

Fixture Platform G/H

Diameter (D)

4.8 (Regular)

5.0 6.0

6.0 (Wide)

1.5

G/H 2.5

3.5

IALR515O

IALR525O

IALR535O

IALW615O

IALW625O

IALW635O

D

In-Octa Locking Abutment Screw

- Instrumentation required 1.2Hex Driver

Unit : mm

Length (L)

Fixture Platform

9

10

11

12

4.8 (Regular)

SSLR5515H

SSLR5525H

SSLR5535H

SSLR5545H

6.0 (Wide)

SSLW6515H

SSLW6525H

SSLW6535H

SSLW6545H

L

Impression Plastic Cap

Unit : mm

Code SIYC 600

In-Octa YK Transfer Adapter

Unit : mm

Fixture Platform 4.8 6.0 D

G/H

Code

1.5 3.5 1.5 3.5

ITLR150 ITLR350 ITLW150 ITLW350

In-Octa YK Transfer Adapter Screw

Unit : mm

Length (L)

Code

9 11

ISTL090

L

In-Octa Locking Lab Analog

- Packing unit : Included Upper+Lower Fixture Platform 4.8 6.0

(Upper)

58

(Lower)

SHINSAEGI MEDI-TECH

ISTL110

Unit : mm

Type

Code

Upper Lower Upper Lower

ILTL481 ILTL482 ILTL601 ILTL602

IST & IT System In-Octa Gold Abutment

- Gold Alloy - Packing unit : Included abutment screw ISCT001 - Torque recommendation : 30Ncm Platform Diameter (D)

6.0

IAGI48O IAGI48N IAGI60O IAGI60N

Non-Octa

In-Octa Impression Coping (pick-up)

- Packing unit : Included Guide pin Platform Diameter

Unit : mm

Type

Code

Octa Non-Octa Octa Non-Octa

4.8 6.0

Octa

Code

Octa Non-Octa Octa Non-Octa

4.8

Octa

Unit : mm

Type

IIPI48O IIPI48N IIPI60O IIPI60N

Non-Octa

In-Octa Guide Pin(pick-up)

- Instrumentation required 1.2Hex Driver

Unit : mm

Height (H)

Code

19

ISGI19O

In-Octa Impression Coping (Transfer)

Unit : mm

Platform Diameter 4.8 6.0

In-Octa Guide Pin(Transfer)

Type

Code

Octa Non-Octa Octa Non-Octa

IITI48O IITI48N IITI60O IITI60N

- Instrumentation required 1.2Hex Driver

Unit : mm

Code ISGT100

In-Octa Lab Analog

Unit : mm

Platform Diameter 4.8 6.0

Code ILC400 ILC600

SHINSAEGI MEDI-TECH

59

Prosthetic Flow Diagram For IST And IT System Screw Retained Restoration Component for Octa Abutment

62p

(Gold) (Ti) Cylinder Screw 61p

61p

(Octa) (Non- Octa) Octa Gold Cylinder

(Octa) (Non- Octa) Octa Plastic Cylinder

62p

Octa Lab Analog

62p

(Octa) (Non-Octa) Octa Impression Coping(Pick-up) 68p

61p

Octa Healing Cap

1.2Hex Torque Driver

68p 61p

Octa Driver

Octa Abutment 67p

52p

Cover Screw

Headless Cover Screw

46p

Internal Slightly Fixture(IST)

60

SHINSAEGI MEDI-TECH

52p

52p

Healing Abutment

50p

Internal Tapered Fixture(IT)

1.2Hex Hand Driver

IST & IT System

06 Octa Abutment

- Screw retained restoration - Instrumentation required octa driver - Torque recommendation : 30Ncm

Unit : mm

Platform Diameter

Code

4.8 6.0

Octa Abutment Healing Cap

IAO100

- For use protect for octa abutment - Included Ti screw(ISOC400) - Instrumentation required 1.2Hex Torque driver - Torque recommendation : 20Ncm Platform Diameter 4.8 6.0

Octa Gold Cylinder

ICO400 ICO600

- Gold alloy - Packing unit : Included abutment screw(ISOC400) - Torque recommendation : 20Ncm Platform 4.8 6.0

Octa

Unit : mm

Code

Unit : mm

Type

Product

Octa

IAGO48O

Non-Octa

IAGO48N

Octa

IAGO60O

Non-Octa

IAGO60N

Non-Octa

Octa Plastic Cylinder

- Packing unit : Included cylinder screw (ISOC400) - Torque recommendation : 30Ncm Platform 4.8 6.0

Type

Unit : mm

Product

Octa

IAPY48O

Non-Octa

IAPY48N

Octa

IAPY60O

Non-Octa

IAPY60N

SHINSAEGI MEDI-TECH

61

IST & IT System Octa Abutment and Cylinder Screw

- Instrument required 1.2Hex Torque driver

Unit : mm

Code ISOC40O Gold

Ti

Octa Impression Coping (pick-up)

- Packing unit : Included guide pin Platform Diameter 4.8 6.0

Octa

Unit : mm

Type

Product

Octa

IIPO48O

Non-Octa

IIPO48N

Octa

IIPO60O

Non-Octa

IIPO60N

Non-Octa

Guide Pin (pick-up)

- Instrument required 1.2Hex Torque driver

Unit : mm

Height (H)

Product

15

ISGO15O

Platform Diameter

Product

Octa Lab Analog

Unit : mm

4.8 6.0

62

SHINSAEGI MEDI-TECH

ILO40O ILO60O

Prosthetic Flow Diagram For IST And IT System Overdenture Retained Restoration for O-Ring Abutment

64p

64p

For Denture O-Ring (Red)

For Laboratory O-Ring (Black)

64p

Retainer

64p

O-Ring Lab Analog

64p

68p

O-Ring Abutment

O-Ring Abutment Driver (2.4Hex) 67p

52p

Internal Cover Screw

52p

52p

Internal Headless Cover Screw

46p

Internal Slightly Fixture(IST)

Healing Abutment

1.2Hex Hand Driver

50p

Internal Tapered Fixture(IT)

SHINSAEGI MEDI-TECH

63

IST & IT System

07 O-Ring Abutment L

- Overdenture restoration - Multiple implant bone retained and fixed removable overdentures. - Collar height : 0, 2, 4mm - Packing unit : Included O-Ring 2ea and O-Ring retainer 1ea - Instrument required O-Ring abutment driver(2.4Hex) - Torque recommendation : 30Ncm

Unit : mm

D

Diameter (D) 3.5

0

Length (L) 2.0

4.0

IAR400

IAR420

IAR440

O-Ring

O-Ring Retainer

Unit : mm

Type

Code

Red(Denture)

IARR002

Black(Laboratory)

IARR003

- Female receptacle processed into denture

Unit : mm

Code IARR001

O-Ring Lab Analog

Unit : mm

Code RL001

64

SHINSAEGI MEDI-TECH

Surgical Instrument Esthetic & Innovation

SHINSAEGI MEDI-TECH SHINSAEGI MEDI-TECH

65

Surgical Instrument

Guide Drill Straight Drill Tapered Drill Hand Driver Machine Driver Torque Driver Fixture Mount Driver Depth gauge Drill Extension Locking Abutment Screw ALIPS Driver Positioning Guide Parallel Pin Torque Wrench Holding Key Bone Profiler & Guide Pin Path Pin Reamer Handle Reamer Guide Reamer Bite Bone Mill Tissue Punch Drill System Surgical Drilling Protocol Drill Dimensions Surgical Protocol Surgical Kit Contents

66

SHINSAEGI MEDI-TECH

67p 67p 67p 67p 68p 68p 68p 69p 69p 69p 69p 69p 69p 69p 69p 70p 70p 70p 70p 70p 70p 70p 71p 71p 71p 72p 74p

Surgical Instrument Guide Drill

- This drill has a unique pointed tip, making this an excellent drill for starting the osteotomy.

Unit : mm

Straight Drill

Type

Code

Application

Lance

KRG160

Start drill

- This drills are designed to increase the depth of the osteotomy. Unit : mm

Diameter

2.0

Tapered Drill

Length

Code

7 9 11 13 15 17

KRS2007

Application

KRS2009 KRS2011 KRS2013

Depth drill

KRS2015 KRS2017

- Tapered series of drills follows in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed. Unit : mm

Diameter 2.0/2.8 2.0/3.3 2.1/3.6 2.5/4.0 2.8/4.5 3.2/4.8 3.3/5.0 4.0/5.8

Hand Driver

Code

Short( 7, 9, 11)

KRT2028S

Long (13, 15, 17)

KRT2028L

Short( 7, 9, 11)

KRT2033S

Long (13, 15, 17)

KRT2033L

Short( 7, 9, 11)

KRT2136S

Long (13, 15, 17)

KRT2136L

Short( 7, 9, 11)

KRT2540S

Long (13, 15, 17)

KRT2540L

Short( 7, 9, 11)

KRT2845S

Long (13, 15, 17)

KRT2845L

Short( 7, 9, 11)

KRT3248S

Long (13, 15, 17)

KRT3248L

Short( 7, 9, 11)

KRT3350S

Long (13, 15, 17)

KRT3350L

Short( 7, 9, 11)

KRT4058S

Long (13, 15, 17)

KRT4058L

- For use tip-holding function by hand Diameter External 1.2Hex External 0.9Hex

1.2Hex

Length

Application

Width increasing drill

Unit : mm

Length

Code

Application

Short

KDH120S

Long

KDH120L

Healing abutment, UCLA Abutment screw, Internal cover screw

Short

KDH090S

Long

KDH090L

External cover screw (N, R, W, W6.0)

0.9Hex

SHINSAEGI MEDI-TECH

67

Surgical Instrument Machine Driver

- For use hand-piece of Motor Diameter

Length

Code

Application

Short

KDM120S

Healing abutment, UCLA Abutment screw, Internal cover screw

External 1.2Hex External 0.9Hex

1.2Hex

Unit : mm

Long

KDM120L

Short

KDM090S

Long

KDM090L

External cover screw (N, R, W, W6.0)

0.9Hex

- For use Torque Wrench - For use Torque function

Torque Driver

Diameter

Length

Code

Application

Short

KDT120S

Healing abutment, UCLA Abutment screw, Internal cover screw

External 1.2Hex External 0.9Hex Internal 2.0Hex External Type

Internal 2.4Hex Internal 2.7Hex Solid Driver Interal Type

Ex-Solid Driver Octa Driver

Fixture Mount Driver

Unit : mm

Long

KDT120L

Short

KDT090S

Long

KDT090L

Short

KDT200S

Long

KDT200L

Short

KDT240S

Long

KDT240L

Short

KDT270S

Long

KDT270L

Short

KDTS00S

Long

KDTS00L

Short

KDTE00S

Long

KDTE00L

Short

KDT300S

Long

KDT300L

- For pick-up and delivery of Implant Diameter

External cover screw (N, R, W, W6.0) Estheticone and Midicone Abutment screw All of O-Ring Abutment Widecone Abutment screw Solid Abutment Excellent Solid Abutment Octa Abutment

Unit : mm

Length

Length

Code

Narrow( 3.5) Hand piece

Hex

Long

KDMM240L

Regular( 4.1) Hand piece

Hex

Long

KDMM270L

Wide( 5.1) Hand piece

Hex

Long

KDMM340L

Short

KDTM240S

Application

Modrine

Narrow( 3.5) Ratchet

EST

SST

IST & IT

Regular( 4.1) Ratchet

Hex Hex

Wide( 5.1) Ratchet

Hex

All of Size(Sub) Hand piece

Hex

Long

KDTM240L

Short

KDTM270S

Long

KDTM270L

Short

KDTM340S

Long

KDTM340L

Long

KDMM250L

Short

KDTM250S

Long

KDTM250L

Long

KDMM310L

Short

KDTM310S

Long

KDTM310L

For use External implant (EST Series)

Torque

EST

68

SST

SHINSAEGI MEDI-TECH

IST & IT

All of Size(Sub) Ratchet

Hex

All of Size(Internal) Hand piece

Octa

All of Size(Internal) Ratchet

Octa

For use Submerged Implant (SST Series)

For use Internal implant (IST&IT Series)

Surgical Instrument Depth gauge

Drill Extension

- Measurement of drilling depth(EST, SST, IST, IT Implant) Depth Length

Code

7, 9, 11, 13, 15, 17

KID170

- For use drill extension on hand-piece

Unit : mm

Unit : mm

Code KIE300

Repositioning Jig

- For use locking abutment screw

Unit : mm

Code KDHAL110

ALIPS Driver

- For use ALIPS abutment

Unit : mm

Code KDHAP130

Positioning Guide

- Measurement of fixture space

Unit : mm

Width(D)

Code

8 10

KIG080 KIG100

D

Parallel Pin

- Measurement of direction and situation

Unit : mm

Width(D)

Code

4 5

KIP400 KIP500

D

Torque Wrench

Holding Key

- Using for insert implant and tie-up driver

Unit : mm

Torque Power

Code

15, 25, 35 Ncm

KIT450

- Holding for Torque Wrench

Unit : mm

Code KIK850

SHINSAEGI MEDI-TECH

69

Surgical Instrument Bone Profiler & Guide Pin

- For remove from surplus bone Fixture platform 3.5 (Narrow) 4.1 (Regular) 5.1 (Wide) 6.0 (W6.0) 4.8 (N, R, W)

Path Pin

Unit : mm

Interface Diameter

Code

3.6 4.15 5.15 6.05 4.85

KIBN360 KIBR415 KIBW515 KIBW605 KIBW485

- Measurement of path and gingival height

Unit : mm

Code KIH250

Reamer Handle

Unit : mm

Code KIRH

Reamer Guide

Unit : mm

Width

Code

4.5 5.5 6.5

KIRG450 KIRG550 KIRG650

Reamer Bite

Unit : mm

Code KIRB

Bone Mill

- For formation of particulate bone with autogenous bone.

Unit : mm

Code KIBM

Tissue Punch

- Flapless surgery - Laser marking 2, 4, 6mm for easy measurement of gingiva height. Unit : mm

70

SHINSAEGI MEDI-TECH

D

Code

Application

4.1 4.6 5.3 6.3

KICM410

EST, SST(Narrow)

KICM460

EST, IT, IST, SST(Regular)

KICM530

EST, IT, IST, SST(Wide)

KICM630

EST, SST(Wide 6.0)

Drill System Drill (Straight & Tapered Drill)

Guide Drill

Straight Drill

Straight Drill( 2.0) Proceed with the initial straight drill to 7mm, 9mm, 11mm, 13mm, 15mm, 17mm with stopper. 2.0mm is designed to increase the depth of the osteotomy. Thread floss through the hole to prevent accidental swallowing. 2.0 straight drills, the length of the drill tip is 0.5mm. The length of the drill tip is not included in the depth mark measurement. Consist of the diameter 2.0mm straight drills are 7. 9. 11, 13, 15, 17mm length with stopper and not marking system.

Tapered Drill

Tapered Drill ( 2.0/2.8) ( 2.0/3.3) ( 2.1/3.6) ( 2.5/4.0) ( 2.8/4.5) ( 3.2/4.8) ( 3.3/5.0) ( 4.0/5.8) (mm) A series of tapered drills are width drill in order to increase the width of the osteotomy to correspond to the diameter of the implant being placed. Regardless of the tapered drills diameter, the length of the drill tip is 0.3mm The length of the drill tip is not included in the depth mark measurement.

Surgical Drilling Protocol Product Platform Body

EST

SST

IST IT

3.5 4.1 4.1 5.1 3.8 4.3 5.0 6.0 4.8 4.8 6.0

3.4 4.0 5.0 5.9 3.7 4.2 4.9 5.9 4.1 4.8 5.3

Apex

Guide

2.0

2.0/2.8

2.0/3.3

2.1/3.6

2.5/4.0

2.8/4.5

3.2/4.8

3.3/5.0

4.0/5.8

2.4 2.9 3.6 4.3 2.4 2.9 3.6 4.3 2.4 3.4 3.4 4.1 4.0 4.6

Drill Dimensions Drill Diameter

Drill Tip Length

Drill Length 7mm(with stopper) 9mm(with stopper)

2.0mm(straight)

0.5mm

11mm(with stopper) 13mm(with stopper) 15mm(with stopper) 17mm(with stopper)

2.0/2.8mm(tapered) 2.0/3.3mm(tapered) 2.1/3.6mm(tapered)

0.3mm 0.3mm 0.3mm

7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking)

Drill Diameter

Drill Tip Length

2.5/4.0mm(tapered)

0.3mm

2.8/4.5mm(tapered)

0.3mm

3.2/4.8mm(tapered)

0.3mm

3.3/5.0mm(tapered)

0.3mm

4.0/5.8mm(tapered)

0.3mm

-

-

Drill Length 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) 7, 9, 11mm(marking with stopper) 13, 15, 17mm(marking) -

SHINSAEGI MEDI-TECH

71

Surgical Protocol External Slightly Tapered Fixture (EST System)

01

3.4mm Fixture

15mm 0.5mm

D4Bone : Guide D3,D2Bone : Guide : Guide D1Bone

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.0/3.3mm Tapered Drill

Fixture

2.0mm Straight Drill Fixture 2.0mm Straight Drill 2.0/2.8mm Tapered Drill Fixture 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture

02

4.0mm Fixture

15mm 0.5mm

D4Bone : Guide D3,D2Bone : Guide : Guide D1Bone

Guide

2.0mm Straight Drill

2.0mm Straight Drill 2.0mm Straight Drill 2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture

2.0/2.8mm Tapered Drill Fixture 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

03

5.0mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D1Bone 3.2/4.8mm Tapered Drill Fixture

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

Fixture

2.1/3.6mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

04

5.9mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill

4.0/5.8mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill D1Bone 3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

72

SHINSAEGI MEDI-TECH

Fixture

Surgical Protocol Submerged Slightly Tapered Fixture (SST System)

01

3.7mm Fixture

15mm 0.5mm

D4Bone : Guide D3,D2Bone : Guide : Guide D1Bone

Guide

2.0mm Straight Drill

2.0mm Straight Drill 2.0mm Straight Drill 2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.0/3.3mm Tapered Drill

2.1/3.6mm Tapered Drill

Fixture

2.0/2.8mm Tapered Drill Fixture 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill Fixture 2.0/2.8mm Tapered Drill 2.0/3.3mm Tapered Drill 2.1/3.6mm Tapered Drill Fixture

02

4.2mm Fixture

15mm 0.5mm

D4Bone : Guide D3,D2Bone : Guide : Guide D1Bone

Guide

2.0mm Straight Drill

2.0mm Straight Drill 2.0mm Straight Drill 2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.0/2.8mm Tapered Drill 2.0/2.8mm Tapered Drill 2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture

2.0/3.3mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

03

4.9mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D1Bone 3.2/4.8mm Tapered Drill Fixture

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

Fixture

2.1/3.6mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.8/4.5mm Tapered Drill

04

5.9mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.3/5.0mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill D1Bone 3.3/5.0mm Tapered Drill 4.0/5.8mm Tapered Drill Fixture

4.0/5.8mm Tapered Drill

Fixture

2.8/4.5mm Tapered Drill Fixture 2.8/4.5mm Tapered Drill Fixture 2.8/4.5mm Tapered Drill

SHINSAEGI MEDI-TECH

73

Surgical Protocol Internal Slightly Tapered Fixture (IST System) Internal Tapered Fixture(IT System) - IST & IT model are same diameter and same protocol.

01

4.1mm Fixture

15mm 0.5mm

D4Bone : Guide D3,D2Bone : Guide : Guide D1Bone

Guide

2.0mm Straight Drill

2.0mm Straight Drill 2.0mm Straight Drill 2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.0/2.8mm Tapered Drill 2.0/2.8mm Tapered Drill 2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.5/4.0mm Tapered Drill

Fixture Fixture (IST) (IT)

2.0/3.3mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture

02

4.8mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill D1Bone 2.8/4.5mm Tapered Drill Fixture

2.5/4.0mm Tapered Drill

2.8/4.5mm Tapered Drill

Fixture Fixture (IST) (IT)

2.1/3.6mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill Fixture 2.1/3.6mm Tapered Drill 2.5/4.0mm Tapered Drill

03

5.3mm Fixture

15mm 0.5mm

Guide

2.0mm Straight Drill

2.0/2.8mm Tapered Drill

2.1/3.6mm Tapered Drill

2.8/4.5mm Tapered Drill

3.2/4.8mm Tapered Drill

D4Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill D3,D2Bone : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill 3.2/4.8mm Tapered Drill Fixture : Guide 2.0mm Straight Drill 2.0/2.8mm Tapered Drill 2.1/3.6mm Tapered Drill D1Bone 3.2/4.8mm Tapered Drill 3.3/5.0mm Tapered Drill Fixture

74

SHINSAEGI MEDI-TECH

3.3/5.0mm Tapered Drill

Fixture Fixture (IST) (IT)

2.5/4.0mm Tapered Drill Fixture 2.5/4.0mm Tapered Drill 2.8/4.5mm Tapered Drill

Surgical Kit External Kit (EST)

Internal Kit (SST, IST, IT)

SHINSAEGI MEDI-TECH

75

Surgical Kit Contents External Kit(EST) No

Type

1

Guide Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0/2.8 Tapered Drill(S) 2.0/2.8 Tapered Drill(L) 2.0/3.3 Tapered Drill(S) 2.0/3.3 Tapered Drill(L) 2.1/3.6 Tapered Drill(S) 2.1/3.6 Tapered Drill(L) 2.5/4.0 Tapered Drill(S) 2.5/4.0 Tapered Drill(L) 3.2/4.8 Tapered Drill(S) 3.2/4.8 Tapered Drill(L) 3.3/5.0 Tapered Drill(S) 3.3/5.0 Tapered Drill(L) 4.0/5.8 Tapered Drill(S) 4.0/5.8 Tapered Drill(L) Drill extension Fixture Mount Driver(Machine) Narrow Fixture Mount Driver(Machine) Regular Fixture Mount Driver(Machine) Wide Fixture Mount Driver(Torque) Narrow(L) Fixture Mount Driver(Torque) Narrow(S) Fixture Mount Driver(Torque) Regular(L) Fixture Mount Driver(Torque) Regular(S) Fixture Mount Driver(Torque) Wide(L) Fixture Mount Driver(Torque) Wide(S) Hex 0.9 Driver for Hand(L) Hex 0.9 Driver for Hand(S) Hex 0.9 Driver for Machine(L) Hex 0.9 Driver for Machine(S) Hex 0.9 Driver for Torque(L) Hex 0.9 Driver for Torque(S) Hex 1.2 Driver for Hand(L) Hex 1.2 Driver for Hand(S) Hex 1.2 Driver for Machine(L) Hex 1.2 Driver for Machine(S) Hex 1.2 Driver for Torque(L) Hex 1.2 Driver for Torque(S) Hex 2.0 Driver(L) Hex 2.0 Driver(S) Hex 2.7 Driver(L) Hex 2.7 Driver(S) Hex 2.4 Driver(L) Hex 2.4 Driver(S)

2

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44

45 Parallel Pin 46 Positioning Guide 47 Torque Wrench 45N cm 48 Holding Key 49 Depth Gauge

Internal Kit(SST, IST, IT) Length Q'Ty

7mm 9mm 11mm 13mm 15mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm

4mm 5mm 8mm 10mm

7~17mm

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Total 56

Application

No

Type

Start Drill Depth Drill Depth Drill Depth Drill Depth Drill Depth Drill Depth Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill For use drill and handpiece tools extension Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External Mountless delivery for External

1

Guide Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0 Straight Drill 2.0/2.8 Tapered Drill(S) 2.0/2.8 Tapered Drill(L) 2.0/3.3 Tapered Drill(S) 2.0/3.3 Tapered Drill(L) 2.1/3.6 Tapered Drill(S) 2.1/3.6 Tapered Drill(L) 2.5/4.0 Tapered Drill(S) 2.5/4.0 Tapered Drill(L) 2.8/4.5 Tapered Drill(S) 2.8/4.5 Tapered Drill(L) 3.2/4.8 Tapered Drill(S) 3.2/4.8 Tapered Drill(L) 3.3/5.0 Tapered Drill(S) 3.3/5.0 Tapered Drill(L) Drill extension Fixture Mount Driver for Machine(Hex)(L) Fixture Mount Driver for Torque (L) Fixture Mount Driver for Torque (S) Fixture Mount Driver for Machine(Octa)(L) Fixture Mount Driver for Torque (L) Fixture Mount Driver for Torque (S) Hex 1.2 Driver for Hand(L) Hex 1.2 Driver for Hand(S) Hex 1.2 Driver for Machine(L) Hex 1.2 Driver for Machine(S) Hex 1.2 Driver for Torque(L) Hex 1.2 Driver for Torque(S) Octa Driver for Torque(L) Octa Driver for Torque(S) Solid Driver for Torque(L) Solid Driver for Torque(S) Excellent Solid Driver for Torque(L) Excellent Solid Driver for Torque(S) Hex 2.4 Driver for Torque(L) Hex 2.4 Driver for Torque(S)

External Cover Screw (N, R, W, W6.0)

Abutment Screw Healing Abutment, Locking Abutment Screw, Cylinder Screw For Estheticone, Midicone For Estheticone, Midicone For Widecone For Widecone For O-Ring For O-Ring Measurement of direction and situation Measurement of direction and situation Measurement of fixture space Measurement of fixture space Insert implant and tie-up driver Holding for Torque Wrench Measurement of drilling depth

2

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37

38 Parallel Pin 39 Positioning Guide 40 Torque Wrench 45N cm 41 Holding Key 42 Depth Gauge

SHINSAEGI MEDI-TECH

7mm 9mm 11mm 13mm 15mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm 11mm 17mm

4mm 5mm 8mm 10mm

7~17mm

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Application

Start Drill Depth Drill Depth Drill Depth Drill Depth Drill Depth Drill Depth Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill Width Increasing Drill For use drill and handpiece tools extension Mountless delivery for Internal Hex(SST) Mountless delivery for Internal Hex(SST) Mountless delivery for Internal Hex(SST) Mountless delivery for Internal Octa(IST/IT) Mountless delivery for Internal Octa(IST/IT) Mountless delivery for Internal Octa(IST/IT) Cover Screw, Abutment Screw Healing Abutment, 6.0 Excellent Solid Abutment, Locking Abutment Screw, In-Octa Cemented Abutment, Sub Solid Abutment, Cylinder Screw Octa Abutment Solid Abutment Excellent Solid Abutment O-Ring Abutment Measurement of direction and situation Measurement of fixture space Insert implant and tie-up driver Holding for Torque Wrench Measurement of drilling depth

Total 49

Option No

Type

1

Bone Profile and Guide Pin

2 3

Path Pin Reamer Handle

4

Reamer Guide

5 6

Reamer Bite Bone Mill

7

76

Length Q'Ty

Tissue punch

Length Q'Ty

3.6 4.15 5.15 6.05 4.85

4.5 5.5 6.5

4.1 4.6 5.3 6.3

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Total 16

Application

For remove from surplus bone.

Measurement of path and height gingiva