Defrost Heaters (1-Phase)

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food) ORZH ELECTRICAL DATA Case Fans Length Per Case 2-door 2 3-door 3 4-door 4 5-...
Author: Blaise Cole
5 downloads 0 Views 122KB Size
High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH ELECTRICAL DATA

Case Fans Length Per Case 2-door 2 3-door 3 4-door 4 5-door 5 6-door 6

High Efficiency Fans 120 Volts Amps Watts 0.60 50.0 1.00 75.0 1.30 100.0 1.60 125.0 1.90 150.0

Defrost Heaters (1-Phase) 208 Volts 240 Volts Amps Watts Amps Watts 7.50 1552 8.60 2068 10.90 2274 12.60 3018 14.30 2984 16.60 3992 17.50 3640 20.20 4840 20.30 4224 23.40 5624

Drain Heater 120 Volts Amps Watts 1.30 152 1.50 171 1.90 226 2.30 275 2.70 320

Defrost Heaters (3-Phase) 208 Volts 240 Volts Amps Watts Amps Watts 6.50 1552 7.50 2068 9.50 2274 10.90 3018 12.40 2984 14.40 3392 15.10 3640 17.40 4840 17.60 4224 20.30 5624

LIGHTING DATA LED Lighting Case Length 2-door 3-door 4-door 5-door 6-door

Optimax Pro 120 Volts Amps Watts 0.30 39.0 0.50 58.0 0.60 77.0 0.80 96.0 1.00 115.0

GE Immersion 120 Volts Amps Watts 0.30 32.0 0.40 48.0 0.50 64.0 0.70 80.0 0.80 96.0

ANTI-CONDENSATE DATA Combined Anti-Condensate Circuits Anthony 101 LE Door Frame ELMD, ELMH or I90 Doors

Case Length 2-door 3-door 4-door 5-door 6-door

Heated Option (IG and Rails) 120 Volts Amps Watts 2.04 219 2.93 312 3.85 410 4.73 502 5.62 596

Individual Circuits

Low E (Heated Rails Only) 120 Volts Amps Watts 1.6 192 2.27 272 2.97 356 3.63 436 4.3 516

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

Heated Doors Amps Watts 0.78 67 1.17 1.17 1.56 1.56 1.95 1.95 2.34 2.34

Low E Doors Amps Watts 0.34 41 0.51 61 0.68 82 0.85 102 1.02 122

101-LE Door Frame Amps Watts 1.26 151 1.76 211 2.29 275 2.78 334 3.28 394

ORZH 1 Rev Date:

Rev #

06/16/16

0

Revision Description: Page:1 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH GUIDELINES & CONTROL DATA

Superheat Set Point @ Discharge Discharge Bulb Air Air Velocity Evaporator (°F) (°F) (FPM) (°F) Application Door Conventional Parallel Frozen HEATED 1044 1014 3-5 -7 -1 350 Frozen LOW E 988 960 3-5 -7 -1 350 Ice Cream HEATED 1091 1060 3-5 -15 -8 350 Ice Cream LOW E 1027 998 3-5 -15 -8 350 BTUH/door

DEFROST DATA Electric Defrost Defrosts Per Day 1

Hot Gas Defrost

Fail-Safe Termination Run-Off Fail-Safe Termination Run-Off (Min) Temp (°F) Time (min) (Min) Temp (°F) Time (min) 46 50 0 24 73 13-15

NOTES: • • • • • • • • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

Drain heater and fan motors share the same circuit (seperate cycles). Electrical circuits must be properly sized to accommodate the higher current draw of the tank heater. Defrost heater 3-phase load is unbalanced. 3-phase defrost heater data listed represent the maximum amps per phase. Data listed for Optimax Pro lighting represent the low power option. High power lights are also available. Anti-condensate heat values for Eliminaator represent a door with no heat on the glass. Listed discharge air velocity represents the average velocity at the peak of defrost. If a discharge air temperature sensor is used to terminate defrost cycle, termination temperature should be set to 55ºF. Listed discharge air velocity represents the average velocity at the peak of defrost. Temperature and defrost settings listed above are recommended start-up settings. Final operational settings may need to be adjusted for the store conditions in which the case operates. The recommended evaporator temperatures may need to be adjusted based on system setup, store conditions, etc. The minimum recommended evaporator temperature is 4°F below the listed evaporator temperature. No run-off time required for electrical defrost. Typical electric defrost time is 20 minutes when ambient conditions are 75°F / 55%RH. Typical electric defrost time is 20 minutes when ambient conditions are 75°F / 55%RH.

ORZH 2 Rev Date:

Rev #

06/16/16

0

Revision Description: Page:2 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH WIRING TO THE TOP (OPTIONAL) 41 7/16" [105.2 cm]

66" [167.6 cm] (Door Height)

85 1/6" [216.0 cm]

27"

68" [172.7 cm] (Frame Height)

27"

64" [162.5 cm]

27"

87 1/4" [221.7 cm]

91 1/4" [231.7 cm]

27"

27"

16 1/4" [41.2 cm]

30 3/8" [77.1 cm]

5 1/8" [13.1 cm]

31 3/4" [80.6 cm] 29 3/16" [74.2 cm] 38 1/8" [96.9 cm] 42 1/16" [106.8 cm]

14" [35.6 cm] 8" [20.3 cm] WIRING TO THE TOP (OPTIONAL)

4" [10.2 cm] PIPING TO THE TOP (OPTIONAL)

REAR REFRIGERATION (14 1/2 IN OFF OF FLOOR)

28 5/8" [72.7 cm]

3 1/8" [7.9 cm]

28 1/2" [72.4 cm]*

1 3/4" [4.4 cm]

31 3/4" [80.6 cm]

34 7/8" [88.6 cm]**

38 1/8" [96.9 cm]

42" [106.7 cm]

4 1/2" [11.4 cm]

REFRIGERATION

ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES)

8 3/4" [22.2 cm] 60" [152.4 cm]

1 1/2" PVC DRAIN CONNECTION

NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

ENDS ADD APPROXIMATELY 1" TO CASE HEIGHT, 1/2" TO THE BACK & 1" TO THE FRONT A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND THE WALL SUCTION LINE (4DR OR LESS) - 1/2", SUCTION LINES (5DR & 6DR)- 5/8" LIQUID LINE (ALL LENGTHS) - 1/2"; BOTH ELECTRIC & HOT GAS DEFROST AVAILABLE SHELF SIZES: SOLID SHELVES 24" & 27 RECOMMENDED CONFIGURATION IS (5) ROWS 24" SHELVES OR (5) ROWS 27" SHELVES

ORZH 2 DOOR Rev Date:

Rev #

06/16/16 06/16/16 06/16/16

0

Revision Description: Page:3 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH WIRING TO THE TOP (OPTIONAL) 41 7/16" [105.2 cm]

66" [167.6 cm] (Door Height)

27"

85 1/6" [216.0 cm]

27"

68" [172.7 cm] (Frame Height)

64" [162.5 cm]

27"

87 1/4" [221.7 cm]

91 1/4" [231.7 cm]

27"

27"

16 1/4" [41.2 cm]

30 3/8" [77.1 cm]

5 1/8" [13.1 cm]

31 3/4" [80.6 cm] 29 3/16" [74.2 cm] 38 1/8" [96.9 cm] 42 1/16" [106.8 cm]

14" [35.6 cm] 8" [20.3 cm] 4" [10.2 cm] REAR REFRIGERATION (14 1/2 IN OFF OF FLOOR)

28 5/8" [72.7 cm]

3 1/8" [7.9 cm]

28 1/2" [72.4 cm]*

1 3/4" [4.4 cm]

31 3/4" [80.6 cm]

34 7/8" [88.6 cm]**

38 1/8" [96.9 cm]

42" [106.7 cm]

WIRING TO THE TOP (OPTIONAL) PIPING TO THE TOP (OPTIONAL)

REFRIGERATION

ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES)

8 3/4" [22.2 cm] 90" [228.6 cm]

1 1/2" [3.8 cm]

1 1/2" PVC DRAIN CONNECTION

NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

ENDS ADD APPROXIMATELY 1" TO CASE HEIGHT, 1/2" TO THE BACK & 1" TO THE FRONT A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND THE WALL SUCTION LINE (4DR OR LESS) - 1/2", SUCTION LINES (5DR & 6DR)- 5/8" LIQUID LINE (ALL LENGTHS) - 1/2"; BOTH ELECTRIC & HOT GAS DEFROST AVAILABLE SHELF SIZES: SOLID SHELVES 24" & 27 RECOMMENDED CONFIGURATION IS (5) ROWS 24" SHELVES OR (5) ROWS 27" SHELVES

ORZH 3 DOOR Rev Date:

Rev #

06/16/16 06/16/16 06/16/16

0

Revision Description: Page:4 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH WIRING TO THE TOP (OPTIONAL) 41 7/16" [105.2 cm]

66" [167.6 cm] (Door Height)

27"

85 1/6" [216.0 cm]

27"

68" [172.7 cm] (Frame Height)

64" [162.5 cm]

27"

87 1/4" [221.7 cm]

91 1/4" [231.7 cm]

27"

27"

16 1/4" [41.2 cm]

30 3/8" [77.1 cm]

5 1/8" [13.1 cm]

31 3/4" [80.6 cm] 29 3/16" [74.2 cm] 38 1/8" [96.9 cm] 42 1/16" [106.8 cm]

14" [35.6 cm] WIRING TO THE TOP (OPTIONAL)

8 3/4" [22.2 cm]

ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES)

28 5/8" [72.7 cm]

4" [10.2 cm]

3 3/8" [8.6 cm]

1 3/4" [4.4 cm]

28 1/2" [72.4 cm]*

PIPING TO THE TOP (OPTIONAL) 31 3/4" [80.6 cm]

34 7/8" [88.6 cm]**

42" [106.7 cm]

4 1/2" [11.4 cm]

38 1/8" [96.9 cm]

REAR REFRIGERATION (14 1/2 IN OFF OF FLOOR)

8" [20.3 cm]

REFRIGERATION

1 1/2" PVC DRAIN CONNECTION

120" [304.8 cm]

1 1/2" [3.8 cm]

NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

ENDS ADD APPROXIMATELY 1" TO CASE HEIGHT, 1/2" TO THE BACK & 1" TO THE FRONT A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND THE WALL SUCTION LINE (4DR OR LESS) - 1/2", SUCTION LINES (5DR & 6DR)- 5/8" LIQUID LINE (ALL LENGTHS) - 1/2"; BOTH ELECTRIC & HOT GAS DEFROST AVAILABLE SHELF SIZES: SOLID SHELVES 24" & 27 RECOMMENDED CONFIGURATION IS (5) ROWS 24" SHELVES OR (5) ROWS 27" SHELVES

ORZH 4 DOOR Rev Date:

Rev #

06/16/16 06/16/16 06/16/16

0

Revision Description: Page:5 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH WIRING TO THE TOP (OPTIONAL) 41 7/16" [105.2 cm]

66" [167.6 cm] (Door Height)

27"

85 1/6" [216.0 cm]

27"

68" [172.7 cm] (Frame Height)

64" [162.5 cm]

27"

87 1/4" [221.7 cm]

91 1/4" [231.7 cm]

27"

27"

16 1/4" [41.2 cm]

30 3/8" [77.1 cm]

5 1/8" [13.1 cm]

31 3/4" [80.6 cm] 29 3/16" [74.2 cm] 38 1/8" [96.9 cm] 42 1/16" [106.8 cm]

14" [35.6 cm] PIPING TO THE TOP (OPTIONAL)

REAR REFRIGERATION (14 1/2 IN OFF OF FLOOR)

8" [20.3 cm]

4" [10.2 cm]

3 1/8" [7.9 cm]

28 1/2" [72.4 cm]*

1 3/4" [4.4 cm]

31 3/4" [80.6 cm]

34 7/8" [88.6 cm]**

38 1/8" [96.9 cm]

42" [106.7 cm]

4 1/2" [11.4 cm]

28 5/8" [72.7 cm]

WIRING TO THE TOP (OPTIONAL)

REFRIGERATION

ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES)

1 1/2" PVC DRAIN CONNECTION

48 1/2" [123.0 cm]

8 3/4" [22.2 cm] 150" [381.0 cm]

1 1/2" [3.8 cm] {END}

NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

ENDS ADD APPROXIMATELY 1" TO CASE HEIGHT, 1/2" TO THE BACK & 1" TO THE FRONT A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND THE WALL SUCTION LINE (4DR OR LESS) - 1/2", SUCTION LINES (5DR & 6DR)- 5/8" LIQUID LINE (ALL LENGTHS) - 1/2"; BOTH ELECTRIC & HOT GAS DEFROST AVAILABLE SHELF SIZES: SOLID SHELVES 24" & 27 RECOMMENDED CONFIGURATION IS (5) ROWS 24" SHELVES OR (5) ROWS 27" SHELVES

ORZH 5 DOOR Rev Date:

Rev #

06/16/16 06/16/16 06/16/16

0

Revision Description: Page:6 - 7

High Reach-In Glass Door Merchandiser 2, 3, 4, 5 & 6 door (Frozen Food)

ORZH WIRING TO THE TOP (OPTIONAL) 41 7/16" [105.2 cm]

85 1/6" [216.0 cm]

27"

66" [167.6 cm] (Door Height) 68" [172.7 cm] (Frame Height)

27"

64" [162.5 cm]

27"

87 1/4" [221.7 cm]

91 1/4" [231.7 cm]

27"

27"

16 1/4" [41.2 cm]

30 3/8" [77.1 cm]

5 1/8" [13.1 cm]

31 3/4" [80.6 cm] 29 3/16" [74.2 cm] 38 1/8" [96.9 cm]

14" [35.6 cm] 8" [20.3 cm]

28 1/2" [72.4 cm]*

1 3/4" [4.4 cm]

31 3/4" [80.6 cm]

34 7/8" [88.6 cm]**

38 1/8" [96.9 cm]

42" [106.7 cm]

REAR REFRIGERATION (14 1/2 IN OFF OF FLOOR)

PIPING TO THE TOP (OPTIONAL)

4" [10.2 cm]

28 5/8" [72.7 cm]

WIRING TO THE TOP (OPTIONAL)

3 1/8" [7.9 cm]

42 1/16" [106.8 cm]

REFRIGERATION ELECTRICAL JUNCTION BOX (WIRING PER LOCAL CODES)

1 1/2" PVC DRAIN CONNECTION 8 3/4" [22.2 cm]

81 5/8" [207.3 cm] 180" [457.2 cm]

1 1/2" [3.8 cm]

NOTES: * : STUB-UP AREA ** : RECOMMENDED STUB-UP CENTERLINE FOR ELECTRICAL AND HUB DRAINS • • • • • •

COMPONENT ALL MEASUREMENTS ARE TAKEN PER ASHRAE-72-2005 SPECIFICATIONS. HILLPHOENIX REFRIGERATED DISPLAY CASES FOR SALE IN THE UNITED STATES MEET OR EXCEED DEPARTMENT OF ENERGY EFFICIENCY REQUIREMENTS.

ENDS ADD APPROXIMATELY 1" TO CASE HEIGHT, 1/2" TO THE BACK & 1" TO THE FRONT A 2" MINIMUM AIR GAP IS REQUIRED BETWEEN THE REAR OF THE CASE AND THE WALL SUCTION LINE (4DR OR LESS) - 1/2", SUCTION LINES (5DR & 6DR)- 5/8" LIQUID LINE (ALL LENGTHS) - 1/2"; BOTH ELECTRIC & HOT GAS DEFROST AVAILABLE SHELF SIZES: SOLID SHELVES 24" & 27 RECOMMENDED CONFIGURATION IS (5) ROWS 24" SHELVES OR (5) ROWS 27" SHELVES

ORZH 6 DOOR Rev Date:

Rev #

06/16/16 06/16/16 06/16/16

0

Revision Description: Page:7 - 7