DANFOSS VARIABLE SPEED DRIVES & SOFT STARTERS

June 2012 - Prices may change without notification

85

VARIABLE SPEED DRIVES & SOFT STARTERS

CONTENTS Danfoss – Variable Speed Drives and Soft Starters Soft Starters VLT® Compact Starter MCD200

87

VLT® Soft Starter MCD500

88

Accessories MCD200/500 Soft Starter

90

Variable Speed Drives & Accessories VLT® Micro Drive

91

VLT® 2800 Series

93

VLT® 2800 Series Common Accessories

94

VLT® HVAC Drive – FC 100 Series

95

VLT® Aqua Drive – FC 200 Series

98

VLT® Automation Drive – FC 300 Series

101

VLT® HVAC Drive FC100/ Aqua Drive FC200/ Automation Drive FC300 Accessories

104

Filters

86

VLT® Advanced Active Filter AAF006

105

VLT® Advanced Harmonic Filter

106

VLT® Power option Sine-wave Filter

107

VLT® Power option dU/dt Filter

108

VSD Cables

110

Glands for VSD cables

111

June 2012 - Prices may change without notification

VLT® Compact Starter MCD 200 from Danfoss includes two families of soft starters in the power range from 7.5-110kW. The series offer easy DIN rail mounting for sizes up to 30 kW, 2-wire or 3-wire start/stop control and excellent starting duty (4x Ie for 6 seconds). Heavy starting ratings at 4x Ie for 20 seconds. Compatible with grounding delta power systems. Input 3 x 200-440 Vac, output 3 x 200-440 Vac Control Supply voltage 24 Vdc or 24 Vac (CV1)

Part No. 175G5220 175G5221 175G5222 175G5223 175G5224 175G5225 175G5226 175G5227 175G5228 175G5229 175G5230

Description Model No. kW 202-007-T4-CV1 202-015-T4-CV1 202-018-T4-CV1 202-022-T4-CV1 202-030-T4-CV1 202-037-T4-CV1 202-045-T4-CV1 202-055-T4-CV1 202-075-T4-CV1 202-090-T4-CV1 202-110-T4-CV1

7.5kW 15kW 19kW 22kW 30kW 37kW 45kW 55kW 75kW 90kW 110kW

VLT® Compact Starter MCD 200

IP

Physical Size HxWxD

Weight kg

IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP00 IP00 IP00

203 X 98 X 163 203 X 98 X 163 203 X 98 X 163 203 X 98 X 163 203 X 98 X 163 215 X 145 X 191 215 X 145 X 191 215 X 145 X 191 240 X 202 X 212 240 X 202 X 212 240 X 202 X 212

2.4 2.4 2.4 2.4 2.4 4.3 4.3 4.3 6.8 6.8 6.8

List $

List $

(Ex. GST)

(Inc. GST)

$1176.00 $1249.50 $1302.00 $1396.50 $1554.00 $1732.50 $2110.50 $2236.50 $2604.00 $3507.00 $3790.50

Description Model No. kW

$1293.60 $1374.50 $1432.20 $1536.20 $1709.40 $1905.80 $2321.60 $2460.20 $2864.40 $3857.70 $4169.60

Discount Code: DA1

Input 3 x 200-440 Vac, output 3 x 200-440 Vac Control Supply voltage 110-240 Vac & 380-440 Vac (CV3)

Part No.

DANFOSS

VLT® Compact Starter MCD 200

IP

Physical Size HxWxD

Weight kg

List $

List $

(Ex. GST)

(Inc. GST)

175G5209

202-007-T4-CV3

7.5kW

IP20

203 X 98 X 163

2.4

$1176.00

$1293.60

175G5210

202-015-T4-CV3

15kW

IP20

203 X 98 X 163

2.4

$1249.50

$1374.50

175G5211

202-018-T4-CV3

19kW

IP20

203 X 98 X 163

2.4

$1302.00

$1432.20

175G5212

202-022-T4-CV3

22kW

IP20

203 X 98 X 163

2.4

$1396.50

$1536.20

175G5213

202-030-T4-CV3

30kW

IP20

203 X 98 X 163

2.4

$1554.00

$1709.40

175G5214

202-037-T4-CV3

37kW

IP20

215 X 145 X 191

4.3

$1732.50

$1905.80

175G5215

202-045-T4-CV3

45kW

IP20

215 X 145 X 191

4.3

$2110.50

$2321.60

175G5216

202-055-T4-CV3

55kW

IP20

215 X 145 X 191

4.3

$2236.50

$2460.20

175G5217

202-075-T4-CV3

75kW

IP00

240 X 202 X 212

6.8

$2604.00

$2864.40

175G5218

202-090-T4-CV3

90kW

IP00

240 X 202 X 212

6.8

$3507.00

$3857.70

175G5219

202-110-T4-CV3

110kW

IP00

240 X 202 X 212

6.8

$3790.50

$4169.60

Discount Code: DA1

VLT® Compact Starter Family MCD 200

June 2012 - Prices may change without notification

87

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT® Soft Starter MCD 500 VLT® Soft Starter MCD 500 is a total motor starting solution. Current transformers measure motor current and provide feedback for controlled motor ramp profiles. Power range 21 – 1600 A, 7.5 – 850 kW (1.2 MW inside Delta Connection) Versions for 200 – 690 VAC

VLT Soft Starter MCD 500

Feature

Benefit

AAC Adaptive Acceleration Control

Automatically adapts to the chosen starting and stopping profile

Adjustable bus bars allow for both top and bottom entry.

Space saving, less cable cost and easy retrofitting

DC injection braking distributed evenly over three phases

Less installation cost and less stress on the motor

Inside Delta (6-wire connection)

Smaller soft starter can be selected for the application

Log menus, 99 events and trip log provide

Eases analysis of the application

information on events, trips and performance Auto Reset

Less down-time

Jog (slow-speed operation)

Application flexibility

Second-order thermal model

Allows motors to be used to their full potential without damage from overloading Saves space and wiring compared to external bypass

Internal bypass contactors (21–215 A, 7.5–110kW)

Very little heat dissipates when running. Eliminates costly external fans, wiring or bypass contactors

Auto-start/stop clock

Application flexibility

Compact size – amongst the smallest in their class

Saves space in cabinets and other application setups

4-line graphical display

Optimum programming approach and setup for viewing operational status

Multiple programming setup (Standard Menu, Extended Menu, Quick Set) Multiple languages

Simplifies the programming, but still holding to maximum flexibility Serving the whole world

Specifications Mains voltage (L1, L2, L3) MCD5-xxxx-T5 MCD5-xxxx-T7 MCD5-xxxx-T7

200 VAC ~ 525 VAC (± 10%) 380 VAC ~ 690 VAC (± 10%) 380 VAC ~ 600 VAC (± 10%) (inside delta connection)

CV1 (A5, A6) CV2 (A5, A6) CV2 (A4, A6) Mains frequency Rated insulation voltage to earth Rated impulse withstand voltage Form designation

24 VAC/VDC (± 20%) 110~120 VAC (+ 10% / - 15%) 220~240 VAC (+ 10% / - 15%) 50/60 Hz (± 10%) 600 VAC 4 kW Bypassed or continuous, semiconductor motor starter form 1

Coordination with semiconductor fuses Coordination with HRC fuses MCD500-0021B to 0215B MCD500-0245C MCD500-1200C to 1600C

Type 2 Type 1 Prospective current of 65 kA Prospective current of 85 kA Prospective current of 100 kA

EMC Emissions (Terminals 13 & 14) EMC Immunity

IEC 60947-4-2 Class B and Lloyds Marine No. 1 Specification IEC 60947-4-2

Relay Outputs

10A @ 250 VAC resistive, 5A; @ 250 VAC AC15 pf 0.3

Relay A (13, 14) Relay B (21, 22, 24) Relay C (33, 34) Analogue Output (07, 08) Maximum Load 24 VDC Output (16, 08) Maximum Load

Normally open Changeover Normally open 0 – 20 mA or 4 – 20 mA ( selectable) 600 Ω (12 VDC @ 20 mA) (accuracy ± 5%) 200 mA (accuracy ± 10%)

Protection MCD5-0021B ~ MCD5-0105B Protection MCD5-0131B ~ MCD5-1600C Operating Temperature Storage Temperature Operating Altitude Humidity Pollution degree

IP 20 & NEMA, UL Indoor Type 1 IP 00, UL Indoor Open Type -10° C to 60° C, above 40° C with derating -25° C to + 60° C 0 – 1000 m, above 1000 m with derating 5% to 95% Relative Humidity Pollution degree 3

During start

4.5 watts per ampere

Control Voltage (terminals A4, A5, A6)

Short circuit capability

Electromagnetic capability (compliant with EU Directive 89/336/EEC) Outputs

Programmable Outputs

Environmental

Heat Dissipation 88

Fully Featured Soft Starter for motors up to 850 kW ➤ ➤ ➤ ➤ ➤ ➤

Total motor starting solution Advanced start, stop and protection features Adaptive Acceleration Control Inside Delta connection 4-line graphical display Multiple programming setup menus

Optional ➤ ➤ ➤

Modules for serial communication - DeviceNet - Profibus - Modbus RTU - USB Remote operator kit PC software: - WinMaster - MCT10

June 2012 - Prices may change without notification

INLINE CONNECTION - INTERNALLY BYPASSED 3 PHASE INPUT 200V-525V, 3 PHASE OUTPUT 200V-525V 690 V VERSION UPON REQUEST AC-53 Rating for bypassed operation (Exp MCD5-0021B) based on 3 times FLC. Control Voltage: 24Vdc/ac

Part No. 175G5500 175G5501 175G5502 175G5503 175G5504 175G5505 175G5506 175G5507 175G5508 175G5509 175G5510 175G5511

Model No.

Description

MCD5-0021B MCD5-0037B MCD5-0043B MCD5-0053B MCD5-0068B MCD5-0084B MCD5-0089B MCD5-0105B MCD5-0131B MCD5-0141B MCD5-0195B MCD5-0215B

IP

Current @ 3 x FLC

21amps 37amps 43amps 53amps 68amps 84amps 89amps 105amps 131amps 141amps 195amps 215amps

IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP00 IP00 IP00

Control Voltage: 110 - 120Vac or 220 - 24-Vac

Part No. 175G5525 175G5526 175G5527 175G5528 175G5529 175G5530 175G5531 175G5532 175G5533 175G5534 175G5535 175G5536

Description Model No. Current @ 3 x FLC

MCD5-0021B MCD5-0037B MCD5-0043B MCD5-0053B MCD5-0068B MCD5-0084B MCD5-0089B MCD5-0105B MCD5-0131B MCD5-0141B MCD5-0195B MCD5-0215B

IP

21amps 37amps 43amps 53amps 68amps 84amps 89amps 105amps 131amps 141amps 195amps 215amps

IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP00 IP00 IP00 IP00

Physical Size HxWxD

295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 438 X 275 X 250 438 X 275 X 250 438 X 275 X 250 438 X 275 X 250

Weight kg 4.2 4.2 4.2 4.2 4.5 4.9 4.9 4.9 14.9 14.9 14.9 14.9

Physical Size Weight HxWxD kg

295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 295 X 150 X 183 438 X 275 X 250 438 X 275 X 250 438 X 275 X 250 438 X 275 X 250

4.2 4.2 4.2 4.2 4.5 4.9 4.9 4.9 14.9 14.9 14.9 14.9

List $

(Ex. GST)

$1690.50 $1921.50 $1942.50 $1974.00 $2152.50 $2352.00 $2866.50 $2950.50 $3129.00 $3381.00 $4578.00 $4956.00

List $

(Ex. GST)

$1690.50 $1921.50 $1942.50 $1974.00 $2152.50 $2352.00 $2866.50 $2950.50 $3129.00 $3381.00 $4578.00 $4956.00

List $

DANFOSS

VLT® Soft Starter MCD 500

(Inc. GST) $1859.60 $2113.70 $2136.80 $2171.40 $2367.80 $2587.20 $3153.20 $3245.60 $3441.90 $3719.10 $5035.80 $5451.60

List $

(Inc. GST) $1859.60 $2113.70 $2136.80 $2171.40 $2367.80 $2587.20 $3153.20 $3245.60 $3441.90 $3719.10 $5035.80 $5451.60

INLINE CONNECTION - NON BYPASSED / CONTINUOUS 3 PHASE INPUT 200V-525V, 3 PHASE OUTPUT 200V-525V 690 V VERSION UPON REQUEST AC-53 Rating for Continuous operation (Exp MCD5-0021B) based on 3 times FLC. Control Voltage: 24Vdc/ac

Part No. 175G5512 175G5513 175G5514 175G5515 175G5516 175G5517 175G5518 175G5519 175G5520 175G5523 175G5524

Description Model No. Control Voltage

MCD5-0245C MCD5-0360C MCD5-0380C MCD5-0428C MCD5-0595C MCD5-0619C MCD5-0790C MCD5-0927C MCD5-1200C MCD5-1410C MCD5-1600C

245amps 360amps 380amps 428amps 595amps 619amps 790amps 927amps 1200amps 1410amps 1600amps

IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00

Physical Size HxWxD

460 X 390 X 279 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 856 X 585 X 364 856 X 585 X 364 856 X 585 X 364

Weight kg 23.9 50.1 50.1 50.1 53.1 53.1 53.1 53.1 120 120 120

$5103.00 $5754.00 $6048.00 $6604.50 $8085.00 $9082.50 $10941.00 $15708.00 $21451.50 $26113.50 $31479.00

IP

Physical Size HxWxD

Weight kg

(Ex. GST)

IP

List $

(Ex. GST)

List $

(Inc. GST)

$5613.30 $6329.40 $6652.80 $7265.00 $8893.50 $9990.80 $12035.10 $17278.80 $23596.70 $28724.90 $34626.90

Control Voltage: 110 - 120Vac or 220 - 24-Vac

Part No. 175G5537 175G5538 175G5539 175G5540 175G5541 175G5542 175G5543 175G5544 175G5545 175G5546 175G5547

Description Model No. Control Voltage

MCD5-0245C MCD5-0360C MCD5-0380C MCD5-0428C MCD5-0595C MCD5-0619C MCD5-0790C MCD5-0927C MCD5-1200C MCD5-1410C MCD5-1600C

245amps 360amps 380amps 428amps 595amps 619amps 790amps 927amps 1200amps 1410amps 1600amps

IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00 IP00

460 X 390 X 279 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 689 X 430 X 302 856 X 585 X 364 856 X 585 X 364 856 X 585 X 364

June 2012 - Prices may change without notification

23.9 50.1 50.1 50.1 53.1 53.1 53.1 53.1 120 120 120

List $

List $

(Inc. GST)

$5103.00 $5613.30 $5754.00 $6329.40 $6048.00 $6652.80 $6604.50 $7265.00 $8085.00 $8893.50 $9082.50 $9990.80 $10941.00 $12035.10 $15708.00 $17278.80 $21451.50 $23596.70 $26113.50 $28724.90 $31479.00 $34626.90 Discount Code: DA1

89

VARIABLE SPEED DRIVES & SOFT STARTERS

Accessories MCD 200/500 Soft Starters Part No.

Description

List $

List $

(Ex. GST)

(Inc. GST)

Communication Adaptors 175G9000

Modbus module - Used on ALL (Limited data set)

$346.50

$381.20

175G9001

Profibus module - Used on ALL (Limited data set)

$577.50

$635.30

175G9002

DeviceNet module - Used on ALL (Limited data set to connect to 30 MCD’s)

$462.00

$508.20

175G9003

AS-I module - Used on ALL (Limited data set to connect to 30 MCD’s)

$420.00

$462.00

MCD 200 REMOTE PANEL

$609.00

$669.90

$157.50

$173.30

$346.50

$381.20

Remote Panel 175G9004 175G0096

MCD 500 Control Panel LCP501 (only suitable for soft starter mfd. After Sept. 1, 2011)

Miscellaneous 175G9007

Kit Finger Guard - Used on 075 - 110

Discount Code: DA1

Remote Operator Kit

90

June 2012 - Prices may change without notification

to 22 kW. It’s a small drive with maximum strength and reliability. Power range 1 phase 200-240 VAC…..0.18-2.2 kW 3 phase 200-240 VAC…..0.25-3.7 kW 3 phase 380-480 VAC…..0.37-22 kW Feature

Benefit

User friendly Minimum Commissioning

Saves time

Mount-connect-go!

Minimum effort – minimum time

Copy settings via local control panel

Easy programming of multiple drives

Intuitive parameter structure

Minimal manual reading

Complies with VLT® software

Saves commissioning time

Self-protecting features

Lean operation

Process PI-controller

No need for external controller

Automatic Motor Tuning

Ensure optimal match between drive and motor

150% motor torque up to 1 minute

Plenty of brake-away and acceleration torque

Flying start (catch a spinning motor)

Doesn’t trip when started on a spinning (freewheeling) motor

Electronic Thermal Relay (ETR)

Replaces external motor protection

Smart Logic Controller

Often makes PLC unnecessary

Built-in RFI filter

Saves cost and space

Energy saving

Less operation cost

Energy efficiency 98%

Minimises heat loss

Automatic Energy Optimisation (AEO)

Saves 5-15% energy in HVAC applications

Reliable

Maximum uptime

Earth fault protection

Protects the drive

Over temperature protection

Protects motor and drive

Short circuit protection

Protects the drive

Optimum heat dissipation

Longer lifetime

Unique cooling concept with no forced air flow over electronics

Problem-free operations in harsh environments

High quality electronics

Low lifetime cost

High quality capacitors

Tolerates uneven mains supply

All drives full load tested from factory

High reliability

Dust resistant

Increased lifetime

RoHS compliant

Protects the environment

Designed for WEEE

Protects the environment

VLT Micro Drive

The VLT® Micro Drive is a general purpose drive that can control AC motors up

DANFOSS

VLT® Micro Drive

Specifications Mains supply (L1, L2, L3)

Supply voltage Supply frequency Displacement Power Factor (cos φ) near unity Switching on input supply L1, L2, L3

1 x 200–240 V ±10%, 3 x 200–240 V ±10%, 3 x 380–480 V ±10% 50/60 Hz (> 0.98) 1–2 times/min.

Output voltage Output frequency Switching on output Ramp times

0-100% of supply voltage 0–200 Hz (VVC+ mode), 0–400 Hz (U/f mode) Unlimited 0.05-3600 sec

Programmable digital inputs Logic Voltage Level

5 PNP or NPN 0-24 VDC

Programmable pulse inputs Voltage Level Pulse input frequency *One of the digital inputs can be used for pulse inputs

1* 0-24 VDC (PNP positive logic) 20-5000 Hz

Analogue inputs Modes Voltage Level Current Level

2 1 current/1 voltage or current 0-10 V (scaleable) 0/4 to 20 mA (scaleable)

Programmable analogue outputs Current range at analogue output

1 0/4-20 mA

Programmable relay outputs

1 (240 VAC, 2 A)

Output data (U,V,W)

Digital inputs

Pulse inputs

Analogue input

Analogue output Relay outputs Approvals

CE, C-tick, UL

Fieldbus communication FC protocol, Modbus RTU

June 2012 - Prices may change without notification

91

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT®Micro Drive FC51, 200 – 240 V, 1 – PHASE with Cat. C1 (reduced length)/ C2 RFI Filter VLT kW Type

Part No.

Description

132F0001

FC-051PK 18S2E20H3XXCXXXSXXX FC-051PK 37S2E20H3XXCXXXSXXX FC-051PK 75S2E20H3XXCXXXSXXX FC-051P1K 5S2E20H3BXCXXXSXXX FC-051P2K 2S2E20H3BXCXXXSXXX

132F0002 132F0003 132F0005 132F0007

Amperes Frame IP 110% Size O/L VT

Physical Size HxWxD

Weight kg (Drive only)

LCP

List $

List $

included? (Ex GST) (Inc GST)

PK18 0.18

1.2

M1

IP20 150 x 70 x 148

1.1

No

$350.00 $385.00

PK37 0.37

2.2

M1

IP20 150 x 70 x 148

1.1

No

$380.00 $418.00

PK75 0.75

4.2

M1

IP20 150 x 70 x 148

1.1

No

$430.00 $473.00

P1K5 1.5

6.8

M2

IP20 180 x 75 x 168

1.6

No

$580.00 $638.00

P2K2 2.2

9.6

M3

IP20 239 x 90 x 194

3.0

No

$730.00 $803.00 Discount Code: DA4

VLT®Micro Drive FC51, 380 – 480 V, 3 – PHASE with Cat. C1 (reduced length)/ C2 RFI Filter Part No.

VLT kW Type

Description

132F0017 FC-051PK 37T4E20H3XXCXXXSXXX 132F0018 FC-051PK 75T4E20H3XXCXXXSXXX 132F0020 FC-051P1K 5T4E20H3BXCXXXSXXX 132F0022 FC-051P2K 2T4E20H3BXCXXXSXXX 132F0024 FC-051P3K 0T4E20H3BXCXXXSXXX 132F0026 FC-051P4K 0T4E20H3BXCXXXSXXX 132F0028 FC-051P5K 5T4E20H3BXCXXXSXXX 132F0030 FC-051P7K 5T4E20H3BXCXXXSXXX 132F0058 FC-051P11K T4E20H3BXCXXXSXXX 132F0059 FC-051P15K T4E20H3BXCXXXSXXX 132F0060 FC-051P18K T4E20H3BXCXXXSXXX 132F0061 FC-051P22K T4E20H3BXCXXXSXXX

Amperes Frame IP 110% Size O/L VT

Physical Size Weight LCP List $ List $ kg HxWxD included? (Ex GST) (Inc GST) (Drive only)

PK37 0.37

1.2

M1

IP20 150 x 70 x 148

1.1

No

$550.00

$605.00

PK75 0.75

2.2

M1

IP20 150 x 70 x 148

1.1

No

$630.00

$693.00

P1K5 1.5

3.7

M2

IP20 180 x 75 x 168

1.6

No

$850.00

$935.00

P2K2 2.2

5.3

M2

IP20 180 x 75 x 168

1.6

No

$1060.00 $1166.00

P3K0 3.0

7.2

M3

IP20 239 x 90 x 194

3.0

No

$1210.00 $1331.00

P4K0 4.0

9

M3

IP20 239 x 90 x 194

3.0

No

$1300.00 $1430.00

P5K5 5.5

12

M3

IP20 239 x 90 x 194

3.0

No

$1520.00 $1672.00

P7K5 7.5

15.5

M3

IP20 239 x 90 x 194

3.0

No

$1730.00 $1903.00

P11K 11

23

M4

IP20 292 x 125 x 241

6.0

No

$2490.00 $2739.00

P15K 15

31

M4

IP20 292 x 125 x 241

6.0

No

$2870.00 $3157.00

P18K 18.5

37

M5

IP20 335 x 165 x 248

9.5

No

$3550.00 $3905.00

P22K 22

443

M5

IP20 335 x 165 x 248

9.5

No

$4170.00 $4587.00 Discount Code: DA4

VLT®Micro Drive FC51 OPTIONS Part No. 132B0100 132B0101 132B0102 132B0103 132B0104 132B0105 132B0106 132B0107 132B0108 132B0109 132B0110 132B0111 132B0120 132B0121

Description VLT Control Panel LCP 11 w/o potentiometer VLT Control Panel LCP 12 with potentiometer Remote Mounting Kit for LCP Nema Type 1 kit for M1 frame Nema Type 1 kit for M2 frame Nema Type 1 kit for M3 frame De-coupling plate kit for M1 and M2 frames De-coupling plate kit for M3 frame IP21 for M1 frame IP21 for M2 frame IP21 for M3 frame DIN rail mounting kit for M1 Nema 1 kit for M4 Nema 1 kit for M5

List $ (Ex GST) $70.00 $70.00 $30.00 $20.00 $30.00 $30.00 $20.00 $20.00 $30.00 $40.00 $50.00 $10.00 $40.00 $50.00

List $ (Inc GST) $77.00 $77.00 $33.00 $22.00 $33.00 $33.00 $22.00 $22.00 $33.00 $44.00 $55.00 $11.00 $44.00 $55.00

Discount Code: DA4 92

June 2012 - Prices may change without notification

VLT 2800 Series

DANFOSS

VLT® 2800 Series

The VLT® 2800 series are among the smallest multi-purpose drives in the market and has been developed for the low power market. The drive is extremely compact and prepared for side-by-side mounting. The concept is modular with a power module and a control module. The VLT® 2800 series is designed for stable operation in industrial environments. Power range 1/3 x 200 – 240 V…..0.37 – 3.7 kW 3 x 380 – 480 V…..0.55 – 18.5 kW With 160% overload torque (normal overload) small Danfoss VLT 2800

Feature

Benefit Ensure optimal match between drive and motor Increasing performance Optimum process control High repeatability of positional accuracy No need for specific detection equipment Allows for control and surveillance of the drives from a PC or a PLC Profibus and DeviceNet are available

Automatic motor tuning PID-controller Interrupt start/stop Dry run detection Fieldbus communication Reliable

Maximum uptime

Built-in RFI filter Enhanced sleep mode Max. ambient temperature 45° without derating

Compliance with the EMC standard EN 55011 1A Excellent control for shutting down the pump at low flow No external cooling or oversizing necessary

User-friendly

Saves commissioning and operating cost

Quick menu Pipe fill mode

Easy to use Prevents water hammering Allows for control and surveillance of the drives from a PC or a PLC Profibus and DeviceNet are available

Fieldbus communication

Specifications Mains supply (L1, L2, L3) Supply voltage Supply frequency Displacement Power Factor (cos φ) near unity Switching on input supply L1, L2, L3 Output data (U,V,W) Output voltage Switching on output Ramp times Closed loop Digital inputs For start/stop, reset, thermistor, etc. Logic Voltage Level Analogue input No. of analogue inputs Voltage Level Current Level Pulse inputs No. of pulse inputs Voltage level Pulse input accuracy Digital output No. of digital outputs Analogue output Programmable analogue outputs Current range Relay outputs No. of relay outputs Fieldbus communication RS485 Ambient temperature 50° C

200-240 V ±10%, 380-480 V ±10% 50/60 Hz (> 0.98) 1-2 times/min. 0-100% of supply voltage Unlimited 1-3600 sec. 0-132 Hz 5 PNP or NPN 0-24 VDC 2 -10 to +10 V (scaleable) 0/4 to 20 mA (scaleable) 2 0-24 V DC (PNP positive logic) (0.1-110 kHz) 1 1 0/4 – 20 mA 1

PC software tools ➤

MCT 10: Ideal for commissioning and servicing the drive.



MCT 31: Harmonics calculations tool.

RFI filter The RFI filter ensures that the frequency converter will not disrupt other electrical components that are connected to the mains and might cause operating disruption. By fitting an RFI 1B filter module between the mains supply and the VLT® 2800, the solution complies with the EMC norm EN 55011-1B.

June 2012 - Prices may change without notification

93

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT2800 1 Phase in / 3 Phase out 200V – 240V Standard REDUCED EARTH LEAKAGE CURRENT FOR USE WITH 30ma RCD’S & ARE NOT SUPPLIED WITH DC COILS NOTE: MOTOR WINDING ARE WIRED IN DELTA

Part No.

VLT

Description Amperes kW

160% O/L CT/VT

Weight kg

List $

List $

IP

Physical Size HxWxD

(Ex. GST)

(Inc. GST)

195N0203

2803

0.37

2.2

IP20

200 X 75 X 168

2

$903.00

$993.30

195N0215

2805

0.55

3.2

IP20

200 X 75 X 168

2

$945.00

$1039.50

195N0227

2807

0.75

4.2

IP20

200 X 75 X 168

2

$1008.00

$1108.80

195N0239

2811

1.1

6

IP20

200 X 75 X 168

2

$1071.00

$1178.10

195N0251

2815

1.5

6.8

IP20

200 X 75 X 168

2

$1228.50

$1351.40

Discount Code: DA1

VLT2800 3 Phase in / 3 Phase out 380V – 480V Standard Part No.

VLT

Description Amperes kW

160% O/L CT/VT

IP

Physical Size HxWxD

Weight kg

List $

List $

(Ex. GST)

(Inc. GST)

195N1003

2805

0.55

1.7

IP20

200 X 75 X 168

2.1

$987.00

$1085.70

195N1015

2807

0.75

2.1

IP20

200 X 75 X 168

2.1

$1144.50

$1259.00

195N1027

2811

1.10

3.0

IP20

200 X 75 X 168

2.1

$1333.50

$1466.90

195N1039

2815

1.50

3.7

IP20

200 X 75 X 168

2.1

$1543.50

$1697.90

195N1051

2822

2.20

5.2

IP20

267.5 X 90 X 168

3.7

$1911.00

$2102.10

195N1063

2830

3.00

7.0

IP20

267.5 X 90 X 168

3.7

$2152.50

$2367.80

195N1075

2840

3.00

7.0

IP20

267.5 X 90 X 168

3.7

$2352.00

$2587.20

195N1087

2855

5.50

12.0

IP20

267.5 X 140 X 168

6

$2793.00

$3072.30

195N1099

2875

7.50

16.0

IP20

267.5 X 140 X 168

6

$3244.50

$3569.00

195N1111

2880

11.00

24.0

IP20

500 X 200 X 244

18.5

$3790.50

$4169.60

195N1123

2881

15.00

32.0

IP20

500 X 200 X 244

18.5

$4368.00

$4804.80

195N1135

2882

18.50

37.5

IP20

500 X 200 X 244

18.5

$5470.50

$6017.60

Discount Code: DA1

VLT® 2800 Series Common Accessories Accessories for the VLT 2800 Part No.

Description

List $ (Ex. GST)

List $ (Inc. GST)

Local Control panel 175N0131

LCP Control Unit – used on ALL

$378.00

$415.80

175N0128

LOP (Local Operation Pad) – used on ALL

$273.00

$300.30

175Z0850

Remote-mount.kit IP00/20, inc 3m cable – used on ALL

$115.50

$127.10

175Z0929

Cable for LCP, 3m – used on ALL

$63.00

$69.30

195N3113

DeviceNet Cable – used on ALL

$115.50

$127.10

Discount Code: DA1 94

June 2012 - Prices may change without notification

The VLT® HVAC Drive series is available in a wide power range designed for all HVAC applications. An advanced drive built on HVAC dedication. The VLT® HVAC Drive is a full-featured, HVAC dedicated drive

Danfoss HVAC series

with built-in intelligence.

DANFOSS

VLT® HVAC Drive – FC100 Series

The VLT® HVAC Drive has a vast number of functions developed to meet the diverse needs of the HVAC

business. It is the perfect match for pumps, fans and compressors in modern buildings that are fitted with increasingly sophisticated solutions. Product range 3 x 200 – 240 V ..............1.1 – 45 kW 3 x 380 – 480 V ..............1.1 – 1000 kW 3 x 525 – 600 V ..............1.1 – 90 kW 3 x 525 – 690 V ..............45 – 1400 kW With 110% over load torque

Available enclosure ratings IP 00 ..........................................45 – 630 kW IP 20 ..........................................1.1 – 90 kW IP 21 (NEMA 1) ...........................1.1 – 1400 kW IP 54 (NEMA 12) .........................45 – 1400 kW IP 55 (NEMA 12) .........................1.1 – 90 kW IP 66 (NEMA 4X indoor) ..............1.1 – 90 kW



Optional coating providing extra protection for aggressive environments.

Feature

Benefit

All built-in – low investment Modular product concept and a wide range of options

Low initial investment – max. flexibility, later upgrade possible

Dedicated HVAC I/O functionality for temperature sensors etc.

External conversion saved

Decentral I/O control via serial communication

Reduced wiring costs, and external controller I/O saved

Wide range of HVAC protocols for BMS controller connectivity

Less extra gateway solutions needed

4 x auto tuned PID’s

No external PID controller needed

Smart Logic Controller

Often makes PLC unnecessary

Real Time Clock

Enables daily and weekly settings Saves external control and conversion equipment

Integrated fan, pump and compressor functionality i.e.

Fire Override Mode, Dry run Detection Constant Torque etc. Protects equipment and saves energy Back-channel cooling for frame D, E and F

Prolonged lifetime of electronics

Save energy – less operation cost Automatic Energy Optimizer function, advanced version Saves 5-15% energy Advanced energy monitoring

Overview of energy consumption

Energy savings functions i.e. flow compensation, sleep mode, etc.

Saves energy

Unequalled robustness – maximum uptime Robust single enclosure

Maintenance-free

Unique cooling concept with no ambient air flow over electronics

Problem-free operation in harsh environments

Max. ambient temp. 50° C without derating

No external cooling or oversize necessary

User-friendly – save commissioning and operating cost Smart start

Quick and precise start-up

Awarded graphical display, 27 languages

Effective commissioning and operation

USB plug and play connection

Easy to use PC software tools

Global HVAC support organisation

Local service - globally

Application options A wide range of integrated HVAC options can be fitted in the drive: General purpose I/O option (MCB 101) 3 digital inputs, 2 digital outputs, 1 analogue current output, 2 analogue voltage inputs. Relay option (MCB 105) Adds 3 relay outputs

Analogue I/O option (MCB 109) 3 Pt1000/Ni1000 inputs, 3 analogue voltage outputs and back-up power for Real-Time Clock. External 24 VDC supply (MCB 107) 24 VDC external supply can be connected to supply, control and option cards. Sensor input card Sensor input card for motor protection with 2 or 3 PT100 or PT1000 inputs (MCB114). Brake chopper (IGBT) option Connected to an external brake resistor, the built-in brake chopper limits the load on the intermediate circuit in the case the motor acts as a generator.

Built-in DC coils and RFI filters – no EMC concerns Integrated DC link harmonic filters

Small power cables. Meets EN 61000-3-12

Integrated EMC filters

Meets EN 55011 Class B, A1 or A2

June 2012 - Prices may change without notification

95

VARIABLE SPEED DRIVES & SOFT STARTERS

Specifications Mains supply (L1, L2, L3)

Supply voltage Supply frequency Displacement Power Factor (cos φ) near unity Switching on input supply L1, L2, L3

200-240 V ±10%, 380-480 V ±10%, 525–600 V ±10%, 525–690 V ±10% 50/60 Hz (> 0.98) 1-2 times/min.

Output voltage Switching on output Ramp times Closed loop

0-100% of supply voltage Unlimited 1-3600 sec. 0-1000 Hz

Programmable digital inputs Logic Voltage Level

6* PNP or NPN 0-24 VDC

Output data (U,V,W)

Digital inputs

*2 can be used as digital outputs

Pulse inputs

Programmable pulse inputs Voltage Level Pulse input accuracy

2* 0-24 VDC (PNP positive logic) (0.1-110 kHz)

*Utilize some of the digital inputs

Analogue input

Analogue inputs Modes Voltage Level Current Level Programmable analogue outputs Current range at analogue output

2 Voltage or current 0 V to +10 V (scaleable) 0/4 to 20 mA (scaleable) 1 0/4 – 20 mA

Programmable relay outputs

2 (240 VAC, 2 A and 400 VAC, 2 A)

Standard built-in: FC Protocol N2 Metasys FLN Apogee Modbus RTU BACnet embedded

Optional: Lon Works (MCA 108) BACnet (MCA 109) DeviceNet (MCA 104) Profibus (MCA 101) Modbus TCP, Ethernet IP, Profinet

Relay outputs

Fieldbus communication

Power options

High power options

Benefits of the EC + concept:

A wide range of external power options are available for VLT® HVAC Drive in critical networks or applications:

➤ IEC Emergency stop with Safety

➤ Free choice of motor

➤ Advanced harmonic filters:



For critical demands on harmonic Distortion

➤ dU/dt filters: For special demands



on motor isolation protection

Relay ➤ Safety Stop with Safety Relay ➤ RFI Filters ➤ NAMUR terminals ➤ RCD ➤ IRM ➤ Mains shielding ➤ Regen terminals

Please see the VLT® High Power Drive Selection Guide for the complete range of options.

➤ Sine wave filters (LC filters):





For noiseless motor

HVAC PC software tools ➤ MCT 10: Ideal for commissioning and servicing the drive ➤ VLT® Energy Box: Comprehensive



energy analysis tool. Energy consumption with and w/o drive can be calculated (drive payback time).Online function for accessing drives energy log.

The Danfoss EC+ concept... ... enables the use of PM motors in IEC-standard sizes with Danfoss VLT® frequency converters. After entering the relevant motor data, you benefit from the high engine efficiency at EC technology level in all applications. Necessary control method has been embedded in dedicated VLT® series drives.



technology:

➤ PM or asynchronous with



same frequency converter

➤ Operation and installation



of the VLT® drive remain the same

➤ Vendor-independent



election of all components

➤ Best system efficiency



by combining efficiency- optimized components

➤ Retrofit of existing plants ➤ Support a broad range of



standard and PM motors

➤ MCT 31: Harmonics calculations tool 96

June 2012 - Prices may change without notification

DANFOSS

➤ CONSTANT or VARIABLE TORQUE – 110%

➤ Rating based upon mains voltage of 380-500V

➤ 3 Phase input 380V – 500V, 3 Phase output 380V – 500V

➤ All drives include graphical LCP

Description Part No.

VLT

kW

Amperes Frame 110% O/L VT/CT

IP

Physical Size Weight List $ List $ HxWxD kg (ex. GST) (inc. GST)

FC102 IP20 (1.1 to 90kw) Standard with Cat. C1 RFI Filter 131B4207 P1K1 1.1 3 A2 IP20 268 x 90 x 205 4.8 $1680.00 $1848.00 131B4217 P1K5 1.5 4.1 A2 IP20 268 x 90 x 205 4.9 $1911.00 $2102.10 131B4218 P2K2 2.2 5.6 A2 IP20 268 x 90 x 205 4.9 $2310.00 $2541.00 131B4219 P3K0 3 7.2 A2 IP20 268 x 90 x 205 4.9 $2572.50 $2829.80 131B3489 P4K0 4 10 A2 IP20 268 x 90 x 205 4.9 $2751.00 $3026.10 131B4220 P5K5 5.5 13 A3 IP20 268 x 130 x 205 6.6 $3181.50 $3499.70 131B3603 P7K5 7.5 16 A3 IP20 268 x 130 x 205 6.6 $3570.00 $3927.00 131F0427 P11K 11 24 B3 IP20 350 x 165 x 248 12 $4599.00 $5058.90 131F6631 P15K 15 32 B3 IP20 350 x 165 x 248 12 $5197.50 $5717.30 131F6632 P18K 18.5 37.5 B3 IP20 350 x 165 x 248 12 $6457.50 $7103.30 131F6629 P22K 22 44 B4 IP20 460 x 230 x 242 23.5 $7528.50 $8281.40 131B5945 P30K 30 61 B4 IP20 460 x 230 x 242 23.5 $8746.50 $9621.20 131F6630 P37K 37 73 B4 IP20 460 x 230 x 242 23.5 $10531.50 $11584.70 131F0340 P45K 45 90 C3 IP20 490 x 308 x 335 35 $12862.50 $14148.80 131F0341 P55K 55 106 C3 IP20 490 x 308 x 335 35 $15561.00 $17117.10 131F0342 P75K 75 147 C4 IP20 600 x 370 x 335 50 $17934.00 $19727.40 131F0343 P90K 90 177 C4 IP20 600 x 370 x 335 50 $20989.50 $23088.50 FC102 IP55 (1.1 to 90kw) Standard with H3 Filter (Cat. C1 RFI filter, reduced cable length) 131U2249 P1K1 1.1 3 A4 IP55 360 x 200 x 190 9.4 $1974.00 $2171.40 131U2251 P2K2 2.2 5.6 A4 IP55 360 x 200 x 190 9.4 $2593.50 $2852.90 131U2252 P3K0 3 7.2 A4 IP55 360 x 200 x 190 9.4 $2856.00 $3141.60 131U1976 P4K0 4 10 A4 IP55 360 x 200 x 190 9.4 $3024.00 $3326.40 131B8214 P5K5 5.5 13 A5 IP55 420 x 242 x 200 14.2 $3433.50 $3776.90 131 B8215 P7K5 7.5 16 A5 IP55 420 x 242 x 200 14.2 $3811.50 $4192.70 131B8216 P11K 11 24 B1 IP55 480 x 242 x 260 23 $5050.50 $5555.60 131B8217 P15K 15 32 B1 IP55 480 x 242 x 260 23 $5722.50 $6294.80 131B8218 P18K 18.5 37.5 B1 IP55 480 x 242 x 260 23 $7161.00 $7877.10 131B6222 P22K 22 44 B2 IP55 650 x 242 x 260 27 $8379.00 $9216.90 131B7356 P30K 30 61 B2 IP55 650 x 242 x 260 27 $9744.00 $10718.40 131B8219 P37K 37 73 C1 IP55 680 x 308 x 310 45 $11581.50 $12739.70 131B8221 P55K 55 106 C1 IP55 680 x 308 x 310 45 $17073.00 $18780.30 FC102 IP55 (1.1 to 90kw) Standard with Cat. C1 RFI Filter 131U2227 P1K1 1.1 3 A4 IP55 360 x 200 x 190 9.4 $2026.50 $2229.20 131U2228 P1K5 1.5 4.1 A4 IP55 360 x 200 x 190 9.4 $2268.00 $2494.80 131U2235 P2K2 2.2 5.6 A4 IP55 360 x 200 x 190 9.4 $2667.00 $2933.70 131U2236 P3K0 3 7.2 A4 IP55 360 x 200 x 190 9.4 $2929.50 $3222.50 131U2237 P4K0 4 10 A4 IP55 360 x 200 x 190 9.4 $3097.50 $3407.30 131B5662 P5K5 5.5 13 A5 IP55 420 x 242 x 200 14.2 $3528.00 $3880.80 131B5663 P7K5 7.5 16 A5 IP55 420 x 242 x 200 14.2 $3927.00 $4319.70 131B4061 P11K 11 24 B1 IP55 480 x 242 x 200 23 $5187.00 $5705.70 131B3319 P15K 15 32 B1 IP55 480 x 242 x 200 23 $5859.00 $6444.90 131B4249 P18K 18.5 37.5 B1 IP55 480 x 242 x 200 23 $7287.00 $8015.70 131B5665 P22K 22 44 B2 IP55 650 x 242 x 260 27 $8505.00 $9355.50 131B5664 P30K 30 61 B2 IP55 650 x 242 x 260 27 $9870.00 $10857.00 131B6662 P37K 37 73 C1 IP55 680 x 308 x 310 45 $11686.50 $12855.20 131B6663 P45K 45 90 C1 IP55 680 x 308 x 310 45 $14259.00 $15684.90 131B6664 P55K 55 106 C1 IP55 680 x 308 x 310 45 $17220.00 $18942.00 131B8508 P75K 75 147 C2 IP55 770 x 370 x 335 65 $19824.00 $21806.40 131B8507 P90K 90 177 C2 IP55 770 x 370 x 335 65 $23142.00 $25456.20 FC102 IP66 (1.1 to 90kw) Standard with Cat. C1 RFI Filter 131U9319 P1K1 1.1 3 A4 IP66 360 x 200 x 190 9.4 $2352.00 $2587.20 131U9320 P1K5 1.5 4.1 A4 IP66 360 x 200 x 190 9.4 $2593.50 $2852.90 131U9321 P2K2 2.2 5.6 A4 IP66 360 x 200 x 190 9.4 $2992.50 $3291.80 131U9322 P3K0 3 7.2 A4 IP66 360 x 200 x 190 9.4 $3255.00 $3580.50 9.4 $3433.50 $3776.90 131U9323 P4K0 4 10 A4 IP66 360 x 200 x 190 131B7636 P5K5 5.5 13 A5 IP66 420 x 242 x 200 14.2 $3853.50 $4238.90 131B7613 P7K5 7.5 16 A5 IP66 420 x 242 x 200 14.2 $4252.50 $4677.80 131B8102 P11K 11 24 B1 IP66 480 x 242 x 200 23 $5470.50 $6017.60 131B8173 P15K 15 32 B1 IP66 480 x 242 x 200 23 $6216.00 $6837.60 131B6981 P18K 18.5 37.5 B1 IP66 480 x 242 x 200 23 $7759.50 $8535.50 131B8231 P22K 22 44 B2 IP66 650 x 242 x 260 27 $9061.50 $9967.70 131B8015 P30K 30 61 B2 IP66 650 x 242 x 260 27 $10531.50 $11584.70 131F4795 P37K 37 73 C1 IP66 680 x 308 x 310 45 $12495.00 $13744.50 131F1272 P45K 45 90 C1 IP66 680 x 308 x 310 45 $15267.00 $16793.70 131F5337 P55K 55 106 C1 IP66 680 x 308 x 310 45 $18448.50 $20293.40 131F4041 P75K 75 147 C2 IP66 770 x 370 x 335 65 $21220.50 $23342.60 131F7721 P90K 90 177 C2 IP66 770 x 370 x 335 65 $24759.00 $27234.90 IP21 Drives available – please contact your local office for information and pricing Discount Code: DA2 June 2012 - Prices may change without notification

97

Danfoss VLT Drives’ unequalled experience was used to make VLT® AQUA Drive the perfect match for AC motor driven applications in modern water and wastewater systems – also for retrofitting. Danfoss VLT® AQUA Drive is dedicated to water and wastewater applications. With a wide range of powerful standard and optional features, VLT® AQUA Drive provides the lowest overall cost of ownership for water and wastewater applications. Perfect match for: ➤

Water supply



Wastewater treatment



District heating



Irrigation

Power range 1 x 200 – 240 V AC ................ 1.1 – 22 kW 1 x 380 – 480 V AC ................ 7.5 – 37 kW 3 x 200 – 240 V AC ..............0.25 – 45 kW 3 x 380 – 480 V AC .........0.37 – 1000 kW 3 x 525 – 600 V AC ..............0.75 – 90 kW 3 x 525 – 690 V AC .............11 – 1400 kW

Feature

Benefit

Dedicated features Dry run detection Flow compensation function 2 step ramps (initial ramp) Check valve ramp

Protects the pump Saves energy Protects deep well pumps Protects against water hammer and saves

Pipe fill mode Built-in motor alternation feature Sleep Mode No/low flow detection End of pump-curve detection Pump cascade controller Back-channel cooling for frame D,E and F

installed cost on soft close valves Eliminates water hammering Duty stand by operation, cost reduction Saves energy Protects the pump Protects the pump, leakage detection Lower equipment cost Prolonged lifetime of electronics

Energy saving

Less operation cost

VLT® efficiency (98%) Automatic Energy Optimisation (AEO) Sleep Mode function Master/follower control Auto Tuning of Staging Speeds Flow compensation

Saves energy Saves 3-8% energy Saves energy Saves up to 15% energy Smoothens the staging and saves energy Saves Energy by self-adjusting the set-point

Reliable

Maximum Uptime

IP 20 – IP 66 enclosures

Outdoor mounting Broad usability in standard factory supplied

All power sizes available in IP 54/55 enclosures Password protection Mains disconnect switch Optional built-in RFI suppression Built-in Smart Logic Controller One Wire safe stop Max. ambient temperature up to 50° C without derating

98

Aqua Family

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT® Aqua Drive – FC200 Series

enclosure Reliable operation No need for external switch No need for external modules Often makes PLC omissible Safe operation / less wiring Reduced need for cooling

User-friendly

Save initial and operation cost

Award winning control panel (LCP) One drive type for the full power range Intuitive user interface Integrated Real Time Clock Modular design Auto tuning of PI-controllers Payback time indication

Effective commissioning and operation Less learning required Time saved Lower equipment cost Enables fast installation of options Time saved Less worries

June 2012 - Prices may change without notification

Application options A wide range of integrated options can be fitted in the drive: General purpose I/O option (MCB 101) 3 digital inputs, 2 digital outputs, 1 analogue current output, 2 analogue voltage inputs. Cascade Controller (MCO 101, 102) Upgrade the built-in cascade controller to operate more pumps with a higher energy efficiency, using master/follower pump control. Running the pumps in use at the same speed and optimising staging speeds automatically during operation. At the same time runtime of all pumps is balanced to distribute wear and tear evenly. Relay & Analogue I/O option (MCB 105, 109) Upgrade to advanced performance and control using the additional in/ outputs. Sensor Input Option (MCB 114) Monitors the PT100/PT1000 installed in the motor winding and bearing temperatures and protects them from overheating according to customised limits.

200-240 V ±10%, 380-480 V ±10%,

Supply voltage Supply frequency Displacement Power Factor (cos φ) near unity True power factor (λ) Switching on input supply L1, L2, L3

525–600 V ±10%, 525–690 V ±10% 50/60 Hz (> 0.98) ≥ 0.9 1-2 times/min.

Output data (U,V,W) Output voltage 0-100% of supply voltage Switching on output Unlimited Ramp times 0.1-3600 sec. Output frequency (dependant on power size) 1000 Hz Note: VLT® AQUA Drive can provide 110% current for 1 minute. Higher overload rating is achieved by oversizing the drive.

Digital inputs Programmable digital inputs Logic Voltage Level *2 can be used as digital outputs

6* PNP or NPN 0-24 VDC

Analogue input Number of analogue inputs Modes Voltage Level Current Level

2 Voltage or current -10 V to +10 V (scaleable) 0/4 to 20 mA (scaleable)

Pulse inputs Programmable pulse inputs 2* Voltage Level 0-24 VDC (PNP positive logic) Pulse input accuracy (0.1-110 kHz) *Two of the digital inputs can be used for pulse inputs.

Analogue output Programmable analogue outputs Current range at analogue output

The MCB 112 is connected to safe stop and protects the motor from overheating. It is approved for controlling a certified Ex proof motor in a potentially explosive atmosphere (ATEX) in zones 1 + 2 (gas) zones 21 + 22 (dust).

Profi bus (MCA 101), DeviceNet (MCA 104) PTC Thermistor Card (MCB 112) Profi net SRT (MCA 120) EtherNet IP (MCA 121) and Modbus TCP (MCA 122) Fieldbus options.

24 V DC supply option (MCB 107) Back-up option to keep the control system alive during mains loss.

1 0/4 – 20 mA

Relay outputs Programmable relay outputs

PTC Thermistor Card (MCB 112)

2 (240 VAC, 2 A and 400 VAC, 2 A)

Fieldbus communication

FC Protocol and Modbus RTU built-in (Optional: Modbus TCP, Profibus, DeviceNet, Ethernet IP)

Ambient temperature

Up to 55°C (50°C without derating)

Coated PCB available For harsh environments, according to levels in IEC61721-3-3, standard 3C2, optional 3C3.

Power options

AQUA PC software tools

We offer a wide range of external power

➤ MCT 10:

options for use together with our drive in critical



Ideal for commissioning and servicing the

networks or applications:



drive including guided programming of



cascade controller, real time clock, smart

➤ VLT® Low Harmonic Drive:



logic controller and preventive



Optimum reduction of harmonic



maintenance.



distortion with built-in active filter.

➤ VLT® Energy Box:

➤ VLT® Advanced Harmonic Filter:



Comprehensive energy analysis tool.



For applications where reducing



Energy consumption with and w/o drive



harmonic distortion is critical.



can be calculated (drive payback time).

➤ dU/dt filter: For providing motor



Online function for accessing drives





energy log.

isolation protection.

➤ Sine wave filter (LC filter):

➤ MCT 31:





For noiseless motor.

DANFOSS

Mains supply (L1, L2, L3)

VLT Aqua Drive

Specifications

Harmonics calculations tool.

Please contact your local office for high power options and more information.

June 2012 - Prices may change without notification

99

VARIABLE SPEED DRIVES & SOFT STARTERS 100

➤ CONSTANT or VARIABLE TORQUE – 110% ➤ 3 Phase input 380V – 500V, 3 Phase output 380V – 500V ➤ Rating based upon mains voltage of 380-500V ➤ All drives include graphical LCP

Part No.

VLT

kW

Description Amperes 110% O/L VT/CT

FC202 IP20 (0.37 to 90kw) Standard 131B8872 PK37 0.37 1.3 131B8880 PK55 0.55 1.8 131B8888 PK75 0.75 2.4 131B8896 P1K1 1.1 3 131B8290 P1K5 1.5 4.1 131B8906 P2K2 2.2 5.6 131B8914 P3K0 3 7.2 131B8932 P4K0 4 10 131B8942 P5K5 5.5 13 131B8289 P7K5 7.5 16 131F6639 P11K 11 24 131F6644 P15K 15 32 131F6648 P18K 18.5 37.5 131F6768 P22K 22 44 131F6773 P30K 30 61 131F6778 P37K 37 73 131F6653 P45K 45 90 131F6657 P55K 55 106 131F6661 P75K 75 147 131F6666 P90K 90 177 FC202 IP21 (11 to 90kW) Standard 131B8980 P11K 11 24 131B8291 P15K 15 32 131B9013 P18K 18.5 37.5 131B9022 P22K 22 44 131B8446 P30K 30 61 131B9043 P37K 37 73 131B8292 P45K 45 90 131B7982 P55K 55 106 131B9068 P75K 75 147 131B9075 P90K 90 177 FC202 IP55 (0.37 to 90kw) standard 131U2462 PK37 0.37 1.3 131U3056 PK55 0.55 1.8 131U3057 PK75 0.75 2.4 131U3058 P1K1 1.1 3 131U3059 P1K5 1.5 4.1 131U3060 P2K2 2.2 5.6 131U3061 P3K0 3 7.2 131U3062 P4K0 4 10 131F1411 P5K5 5.5 13 131F1414 P7K5 7.5 16 131F1415 P11K 11 24 131F1420 P15K 15 32 131F1582 P18K 18.5 37.5 131F1583 P22K 22 44 131F1584 P30K 30 61 131F1585 P37K 37 73 131F1586 P45K 45 90 131F1587 P55K 55 106 131F1588 P75K 75 147 131F1646 P90K 90 177 FC202 IP66 (11 to 90kw) Standard 131Z6695 PK37 0.37 1.3 131Z6696 PK55 0.55 1.8 131Z6697 PK75 0.75 2.4 131Z6698 P1K1 1.1 3 131X4368 P1K5 1.5 4.1 131Z6699 P2K2 2.2 5.6 131Z6700 P3K0 3 7.2 131Z6701 P4K0 4 10 131F0846 P5K5 5.5 13 131F0849 P7K5 7.5 16 131F0850 P11K 11 24 131F0851 P15K 15 32 131F0852 P18K 18.5 37.5 131F0853 P22K 22 44 131F0854 P30K 30 61 131F2919 P37K 37 73 131F2920 P45K 45 90 131F2921 P55K 55 106 131F2922 P75K 75 147 131F2923 P90K 90 177

Frame

IP

Physical Size HxWxD

Weight kg

List $ (ex. GST)

List $ (inc. GST)

A2 A2 A2 A2 A2 A2 A2 A2 A3 A3 B3 B3 B3 B4 B4 B4 C3 C3 C4 C4

IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20

268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 130 x 205 268 x 130 x 205 350 x 165 x 248 350 x 165 x 248 350 x 165 x 248 460 x 230 x 242 460 x 230 x 242 460 x 230 x 242 490 x 308 x 335 490 x 308 x 335 600 x 370 x 335 600 x 370 x 335

4.7 4.7 4.8 4.8 4.9 4.9 4.9 4.9 6.6 6.6 12 12 12 23.5 23.5 23.5 35 35 50 50

$1375.50 $1428.00 $1543.50 $1722.00 $1974.00 $2383.50 $2656.50 $2835.00 $3276.00 $3675.00 $4735.50 $5344.50 $6657.00 $7759.50 $9009.00 $10857.00 $13240.50 $16023.00 $18469.50 $21619.50

$1513.10 $1570.80 $1697.90 $1894.20 $2171.40 $2621.90 $2922.20 $3118.50 $3603.60 $4042.50 $5209.10 $5879.00 $7322.70 $8535.50 $9909.90 $11942.70 $14564.60 $17625.30 $20316.50 $23781.50

B1 B1 B1 B2 B2 C1 C1 C1 C2 C2

IP21 IP21 IP21 IP21 IP21 IP21 IP21 IP21 IP21 IP21

480 x 242 x 260 480 x 242 x 260 480 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

23 23 23 27 27 45 45 45 65 65

$5092.50 $5775.00 $7192.50 $8389.50 $9744.00 $11749.50 $14343.00 $17346.00 $19981.50 $23341.50

$5601.80 $6352.50 $7911.80 $9228.50 $10718.40 $12924.50 $15777.30 $19080.60 $21979.70 $25675.70

A4 A4 A4 A4 A4 A4 A4 A4 A5 A5 B1 B1 B1 B2 B2 C1 C1 C1 C2 C2

IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 420 x 242 x 200 420 x 242 x 200 420 x 242 x 260 420 x 242 x 260 420 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.4 14.2 14.2 23 23 23 27 27 45 45 45 65 65

$1732.50 $1785.00 $1900.50 $2089.50 $2331.00 $2740.50 $3013.50 $3192.00 $3633.00 $4042.50 $5334.00 $6037.50 $7507.50 $8757.00 $10164.00 $12033.00 $14679.00 $17734.50 $20422.50 $23835.00

$1905.80 $1963.50 $2090.60 $2298.50 $2564.10 $3014.60 $3314.90 $3511.20 $3996.30 $4446.80 $5867.40 $6641.30 $8258.30 $9632.70 $11180.40 $13236.30 $16146.90 $19508.00 $22464.80 $26218.50

A4 A4 A4 A4 A4 A4 A4 A4 A5 A5 B1 B1 B1 B2 B2 C1 C1 C1 C2 C2

IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66

360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 420 x 242 x 200 420 x 242 x 200 480 x 242 x 260 480 x 242 x 260 480 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.4 14.2 14.2 23 23 23 27 27 45 45 45 65 65

$2068.50 $2275.40 $2121.00 $2333.10 $2236.50 $2460.20 $2425.50 $2668.10 $2677.50 $2945.30 $3087.00 $3395.70 $3349.50 $3684.50 $3538.50 $3892.40 $3969.00 $4365.90 $4378.50 $4816.40 $5638.50 $6202.40 $6405.00 $7045.50 $7990.50 $8789.60 $9334.50 $10268.00 $10846.50 $11931.20 $12862.50 $14148.80 $15718.50 $17290.40 $18994.50 $20894.00 $21861.00 $24047.10 $25504.50 $28055.00 Discount Code: DA1

June 2012 - Prices may change without notification

Automation Drive Family

DANFOSS

VLT® Automation Drive – FC300 Series

The VLT® AutomationDrive is a single drive concept that covers an entire range of applications, which is a major benefit in commissioning, operating and maintaining the equipment. The modular open-technology platform that VLT® AutomationDrive is built on makes it exceptionally adaptable and programmable. Its configurable, user-friendly interface supports local languages and letters. Perfect match for:

Power range



Industrial Automation



High dynamic applications



Safety installations

3 x 200 – 240 V............0.25 – 37 kW 3 x 380 – 480/500 V.....0.37 – 800 kW 3 x 525 – 600 V............0.75 kW – 75 kW 3 x 535 – 690 V...........37 kW – 1200 kW Normal overload..…...45 – 1400 kW

Feature

Benefit

Reliable

Maximum Uptime

Ambient temperature 50° C without derating

Less need for cooling or oversizing

Available in IP00, 20, 21, 54, 55 and 66 enclosures

Suitable for harsh and wash down areas

Resistant to wear and tear

Low lifetime cost

Back-channel cooling for frame D, E and F

Prolonged lifetime of electronics

User-friendly

Save initial and operation cost

Plug-and-play technology

Easy upgrade and change over

Awarded control panel

User-friendly

Intuitive VLT® interface

Saves time

Pluggable cage clamp connectors

Easy connection

Exchangeable languages

User-friendly

Adapts to the future The modular concept of VLT® AutomationDrive makes it highly adaptable – also to future features and options. Modularity offers the benefit of buying on a need-to-have basis without losing future possibilities.

Hot pluggable Control Panel The Local Control Panel (LCP) can be plugged in directly or connected through a cable for remote commissioning. The LCP can be disconnected during operation and replaced with a blind cover. Settings are easily transferred via the LCP from one drive to another or from a PC to a drive with the VLT® Set-up Software MCT 10. Awarded VLT® AutomationDrive has received the Frost & Sullivan award for innovation and the iF Design Award for its user-friendliness.

Intelligent Intelligent warning systems

Warning before controlled stop

Smart Logic Control

Reduces need for PLC capacity

Advanced plug-in features

Easy commissioning Safety cat. 3 (EN 954-1), PL d (ISO 13849-1),

Safe stop

Stop cat. 0 (EN 60204-1)

STO: Safe Torque Off (IEC 61800-5-2) Intelligent heat management

Pluggable options The drive solution can be adapted to any application due to the flexible option structure. Numerous options are available and can be mounted and tested from factory or be plugged in later for change-over or upgrade.

SIL 2 (IEC 61508) SIL CL 2 (IEC 62061) Intelligent heat management

Automation Drive

June 2012 - Prices may change without notification

101

VARIABLE SPEED DRIVES & SOFT STARTERS

Specifications Mains supply (L1, L2, L3) Supply voltage Supply frequency Displacement Power Factor (cos φ) near unity True power factor (λ) Switching on input supply L1, L2, L3

Output data (U,V,W) Output voltage Switching on output Ramp times

200-240 V ±10% FC 301: 380-480 V ±10% FC 302: 380–500 V ±10%, 525–600 V ±10% 525-690 V ±10% 50/60 Hz (> 0.98) 0.92 nominal at rated load Maximum 2 times/min. 0-100% of supply voltage Unlimited 1-3600 sec. FC 301: 0.2 – 1000 Hz (0.25 – 75 kW) FC 302: 0 – 1000 Hz (0.25 – 75 kW), 0 – 800 Hz (90 – 1200 kW), 0 – 300 Hz (Flux mode)

Output frequency

Note: 160% current can be provided for 1 minute. Higher overload rating is achieved by oversizing the drive.

Digital inputs

Programmable digital inputs FC301: 4 (5) / FC302: 4 (6) Logic PNP or NPN Voltage Level 0-24 VDC Note: One/two digital inputs can be programmed as digital output for FC 301/FC 302.

Analogue input

Number of analogue inputs Modes Current Level

2 Voltage or current FC 301: 0 to +10 V FC 302: -10 V to +10 V (scaleable) 0/4 to 20 mA (scaleable)

Programmable pulse/ encoder inputs Voltage Level

FC 301: 1 / FC 302: 2 0-24 V DC (PNP positive logic)

Voltage Level

Pulse/encoder inputs Digital output*

Programmable digital/ pulse outputs Voltage Level at digital/ frequency output

FC 301: 1 / FC 302: 2 0-24 V

Programmable analogue outputs Current range at analogue output

1 0/4 – 20 mA

Programmable relay outputs

FC 301: 1 / FC 302: 2

Max. motor cable lengths

FC 301: 50 m / FC 302: 150 m (screened/armoured) FC 301: 75 m / FC 302: 300 m (unscreened/ unarmoured)

Analogue output* Relay outputs* Cable lengths

*More analogue and digital inputs/outputs can be added by options.

High power options ➤ ➤ ➤ ➤ ➤ ➤ ➤ ➤

The following options are available:

IEC Emergency stop with Safety Relay Safety Stop with Safety Relay RFI Filters NAMUR terminals RCD IRM Mains shielding Regen terminals

Other accessories ➤ ➤ ➤ ➤ ➤ ➤ ➤ ➤ ➤ 102

IP 21/NEMA 1 Kit (convert IP 20 to IP 21) PROFIBUS adapter Sub-D9 Connector Decoupling plate for fieldbus cables USB connection cable to PC Panel Through option LCP panel mounting kit Mounting brackets Mains disconnect option

Fieldbus options ➤ ➤ ➤ ➤ ➤ ➤ ➤ ➤

MCA 101 Profi bus MCA 104 DeviceNet MCA 105 CanOpen MCA 113 Profi bus VLT® 3000 protocolconverter MCA 114 Profi bus VLT® 5000 protocol converter MCA 120 PROFINET MCA 121 Ethernet IP MCA 122 Modbus TCP

I/O and feedback options ➤ ➤ ➤ ➤ ➤ ➤ ➤

MCB 101 General Purpose I/O MCB 102 Encoder MCB 103 Resolver MCB 105 Relay MCB 107 24 V input option for controlvoltage MCB 113 Extended Relay Card MCB 114 VLT® Sensor Input

Safety options ➤ MCB 108 Safety PLC interface (DC/DC converter) ➤ MCB 112 ATEX-PTC Thermistor Card

Brake chopper (IGBT) option ➤

Connected to an external brake resistor, the built-in brake chopper limits the load on the intermediate circuit in the case the motor acts as a generator.

Motion Control Options ➤ ➤ ➤ ➤

MCO 305 Programmable Motion Controller MCO 350 Synchronizing Controller MCO 351 Positioning Controller MCO 352 Center Winder Controller

Power options ➤ ➤ ➤ ➤

Brake resistors Sine-Wave Filters dU/dt Filters Harmonic Filters (AHF)

June 2012 - Prices may change without notification

➤ Rating based upon mains voltage of 380-500V ➤ All drives include graphical LCP

Part No.

VLT

kW

Description Amperes 110% O/L VT/CT

FC302 IP20 (0.37 to 75kw) Standard 131B0033 PK37 0.37 1.3 131B0034 PK55 0.55 1.8 131B0035 PK75 0.75 2.4 131B0036 P1K1 1.1 3 131B0037 P1K5 1.5 4.1 131B0038 P2K2 2.2 5.6 131B0039 P3K0 3 7.2 131B0040 P4K0 4 10 131B0041 P5K5 5.5 13 131B0042 P7K5 7.5 16 131B9826 P11K 11 24 131F0430 P15K 15 32 131F0431 P18K 18.5 37.5 131B5946 P22K 22 44 131F0434 P30K 30 61 131F0437 P37K 37 73 131F0438 P45K 45 90 131F0444 P55K 55 106 131F0445 P75K 75 147 FC302 IP21 (11 to 75kw) Standard 131B1152 P11K 11 24 131B1155 P15K 15 32 131B1156 P18K 18.5 37.5 131B1864 P22K 22 44 131B4574 P30K 30 61 131B4576 P37K 37 73 131B4578 P45K 45 90 131B4581 P55K 55 106 131B4583 P75K 75 147 FC302 IP55 (0.37 to 75kw) Standard 131U3148 PK37 0.37 1.3 131U6155 PK55 0.55 1.8 131U6160 PK75 0.75 2.4 131U2268 P1K1 1.1 3 131U6178 P1K5 1.5 4.1 131U6185 P2K2 2.2 5.6 131U6188 P3K0 3 7.2 131U5997 P4K0 4 10 131B4638 P5K5 5.5 13 131B4640 P7K5 7.5 16 131B3298 P11K 11 24 131B3312 P15K 15 32 131B4728 P18K 18.5 37.5 131B4729 P22K 22 44 131B6632 P30K 30 61 131B6633 P37K 37 73 131B6636 P45K 45 90 131B9668 P55K 55 106 131F0181 P75K 75 147 FC302 IP66 (0.37 to 75kw) Standard 131U8064 PK37 0.37 1.3 131U8065 PK55 0.55 1.8 131U8066 PK75 0.75 2.4 131U8067 P1K1 1.1 3 131U8068 P1K5 1.5 4.1 131U8069 P2K2 2.2 5.6 131U8070 P3K0 3 7.2 131U8071 P4K0 4 10 131B6359 P5K5 5.5 13 131B6718 P7K5 7.5 16 131B5840 P11K 11 24 131B5605 P15K 15 32 131B6628 P18K 18.5 37.5 131B4621 P22K 22 44 131B6648 P30K 30 61 131F0890 P37K 37 73 131B4526 P45K 45 90 131F0891 P55K 55 106 131F0892 P75K 75 147

DANFOSS

➤ CONSTANT TORQUE – 160% ➤ 3 Phase input 380V – 500V, 3 Phase output 380V – 500V

Frame

IP

Physical Size Weight List $ List $ HxWxD kg (ex. GST) (inc. GST)

A2 A2 A2 A2 A2 A2 A2 A2 A3 A3 B3 B3 B4 B4 B4 C3 C3 C4 C4

IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20 IP20

268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 90 x 205 268 x 130 x 205 268 x 130 x 205 350 x 165 x 248 350 x 165 x 248 460 x 230 x 242 460 x 230 x 242 460 x 230 x 242 490 x 308 x 335 490 x 308 x 335 600 x 370 x 335 600 x 370 x 335

4.7 4.7 4.8 4.8 4.9 4.9 4.9 4.9 6.6 6.6 12 12 12 23.5 23.5 23.5 35 35 50

$1648.50 $1722.00 $1869.00 $2110.50 $2404.50 $2919.00 $3255.00 $3475.50 $4021.50 $4536.00 $6562.50 $8158.50 $9555.00 $11077.50 $13251.00 $16180.50 $19540.50 $22533.00 $25735.50

$1813.40 $1894.20 $2055.90 $2321.60 $2645.00 $3210.90 $3580.50 $3823.10 $4423.70 $4989.60 $7218.80 $8974.40 $10510.50 $12185.30 $14576.10 $17798.60 $21494.60 $24786.30 $28309.10

B1 B1 B2 B2 C1 C1 C1 C2 C2

IP21 IP21 IP21 IP21 IP21 IP21 IP21 IP21 IP21

480 x 242 x 260 480 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

23 23 27 27 45 45 45 65 65

$7014.00 $8736.00 $10227.00 $11865.00 $14206.50 $17356.50 $20947.50 $24139.50 $27573.00

$7715.40 $9609.60 $11249.70 $13051.50 $15627.20 $19092.20 $23042.30 $26553.50 $30330.30

A4 A4 A4 A4 A4 A4 A4 A4 A5 A5 B1 B1 B2 B2 C1 C1 C1 C2 C2

IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55 IP55

360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 420 x 242 x 195 420 x 242 x 195 480 x 242 x 260 480 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.4 14 14 23 23 27 27 45 45 45 65 65

$2037.00 $2100.00 $2247.00 $2488.50 $2793.00 $3297.00 $3633.00 $3853.50 $4410.00 $4924.50 $7297.50 $9072.00 $10615.50 $12316.50 $14511.00 $17724.00 $21367.50 $24612.00 $28108.50

$2240.70 $2310.00 $2471.70 $2737.40 $3072.30 $3626.70 $3996.30 $4238.90 $4851.00 $5417.00 $8027.30 $9979.20 $11677.10 $13548.20 $15962.10 $19496.40 $23504.30 $27073.20 $30919.40

A4 A4 A4 A4 A4 A4 A4 A4 A5 A5 B1 B1 B2 B2 C1 C1 C1 C2 C2

IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66 IP66

360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 360 x 200 x 190 420 x 242 x 195 420 x 242 x 195 480 x 242 x 260 480 x 242 x 260 650 x 242 x 260 650 x 242 x 260 680 x 308 x 310 680 x 308 x 310 680 x 308 x 310 770 x 370 x 335 770 x 370 x 335

9.4 9.4 9.4 9.4 9.4 9.4 9.4 9.4 14 14 23 23 27 27 45 45 45 65 65

$2394.00 $2633.40 $2467.50 $2714.30 $2614.50 $2876.00 $2856.00 $3141.60 $3160.50 $3476.60 $3664.50 $4031.00 $4000.50 $4400.60 $4221.00 $4643.10 $4767.00 $5243.70 $5281.50 $5809.70 $7696.50 $8466.20 $9586.50 $10545.20 $11245.50 $12370.10 $13041.00 $14345.10 $15403.50 $16943.90 $18826.50 $20709.20 $22711.50 $24982.70 $26155.50 $28771.10 $29883.00 $32871.30 Discount Code: DA1

June 2012 - Prices may change without notification

103

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT® HVAC FC100/ AQUA FC 200/ AUTOMATION FC300 ACCESSORIES Part No.

List $ List $ (Ex. GST) (Inc. GST)

Description

Used on

Graphical Local Control Panel 102 Numeric Local Control Panel 101 Panel Mounting Kit inc. Graphical LCP 102 Panel Mounting Kit inc. Numeric LCP 101 Panel Mounting Kit for all LCPs with 3m cable Panel Mounting Kit for all LCPs without cable Cable for all LCPs 3 meters

FC100 / FC200/ FC300 FC100 / FC200/ FC300 FC100 / FC200/ FC300 FC100 / FC200/ FC300 FC100 / FC200/ FC300 FC100 / FC200/ FC300 FC100 / FC200/ FC300

$304.50 $136.50 $462.00 $283.50 $157.50 $94.50 $63.00

$335.00 $150.20 $508.20 $311.90 $173.30 $104.00 $69.30

FC100 FC300 FC100 / FC200 / FC300 FC100 FC100 / FC200 / FC300 FC200 / FC300 FC200 / FC300 FC100 / FC200 / FC300

$357.00 $336.00 $336.00 $451.50 $451.50 $924.00 $934.50 $955.50

$392.70 $369.60 $369.60 $496.70 $496.70 $1016.40 $1028.00 $1051.10

FC100 / FC200 FC300 FC300 FC100 / FC200/ FC300 FC200 FC100 / FC200/ FC300 FC300 FC300 FC200

$357.00 $441.00 $630.00 $283.50 $357.00 $315.00 $714.00 $241.50 $1659.00

$392.70 $485.10 $693.00 $311.90 $392.70 $346.50 $785.40 $265.70 $1824.90

LCP Options 130B1107 130B1124 130B1113 130B1114 130B1117 130B1170 175Z0929

MCA Options (Options for Slot A) 130B1144 130B1103 130B1102 130B1106 130B1100 130B1196 130B1119 130B1135

BACNet (MCA 109) CanOpen (MCA105) DeviceNet (MCA104) LON Works (MCA108) Profibus (MCA101) Modbus TCP (MCA122) Ethernet IP (MCA121) Profinet SRT uncoated (MCA120)

MCB Options (Options for Slot B) 130B1143 130B1137 130B1115 130B1125 130B1172 130B1110 130B1127 130B1120 130B1118

Analog I/O (MCB109) ATEX PTC Thermistor Card Coasted (MCB112) Encoder (MCB102) General Purpose I/O (MCB101) PT100/PT1000 Sensor input (MCB114) Relay Option (MCB105) Resolver (MCB103) Safety PLC Interface (MCB108) Extended Cascade Control (MC0101)

Please contact your local office for other options & accessories to fit your application.

104

June 2012 - Prices may change without notification

Discount Code: DA1

A flexible and adaptable solution for central or de-central harmonic mitigation. Danfoss Advanced Active Filters can compensate for individual VLT® drives or can be installed as a compact stand-alone solution at a common point of coupling, compensating for several loads simultaneously. Consequently the filter ensures optimal harmonic suppression independent of the number of loads and their individual load profile. In addition the active filter corrects the power factor and balances the phase load providing an optimal energy utilization. This improves the system efficiency and increases the grid robustness to avoid downtime.

Active Filter

DANFOSS

VLT® Advanced Active Filter AAF 006

The VLT® Advanced Active Filter is easily controlled via the user-friendly LCP, sharing design and programming structure with the VLT® drives series. Without dismounting existing installation, the VLT® Advanced Active Filters are easily retrofitted to the existing installation, where harmonics are increased because of enlarged employment of non-linear loads such as variable speed drives. Voltage range ➤ 380 – 480 V AC 50 – 60 Hz

Current range ➤ 190 A, 250 A, 310 A, 400 A.

Enclosure degree ➤ IP 21/NEMA Type 1 ➤ IP 54/NEMA Type 12



Up to 4 units can be paralleled for higher power.

Feature

Benefit

Reliable

Maximum Uptime

100% factory tested Coated PCBs >90% components re-used from proven VLT® FC series Innovative cooling concept

Low failure rate

Options The following options are available: ➤ RFI filters ➤ Disconnect ➤ Fuses ➤ Mains shielding

PC software VLT® MCT 10 Setup Software ➤ VLT® MCT 10 offers advanced

programming functionality for all ➤ Danfoss drive products, greatly reducing programming and set-up time.

VLT® MCT 31 Harmonics Calculation Software With VLT® MCT 31, you can determine whether harmonics will be an issue in your installation Saves commissioning and operating costs whendrives are added. Prolonged lifetime of electronics

User-friendly and flexible Innovative programming possibilities Modular design

Low running expenses Easy serviceability Low initial investment

Wide range of options

High degree of customisation

Energy saving

Lower operation costs

From www.danfoss.com you can down-load the free tool VLT® Harmonic Calculation MCT 31 – the most up-to- date version of the calculation software.

High efficiency Sleep mode and progressive switching

Low running expenses

freq. Power factor correction

Specifications THiD* at: – 40% load – 70% load – 100% load Efficiency* at: – 40% load –70% load –100% load True power factor* at: – 40% load –70% load –100% load Ambient temperature Cooling

400 V AC (380 – 480 V AC)

< 7% < 5,5% < 5% >95% >98% >98% >0,98 >0,98 >0,98 45°C Back- channel air cooling

Total Current Max. Reactive Max. Harmonic Frame (A) (A) (A) 190 190 170 D14 250 250 225 E1 310 310 280 E1 400 400 360 E1

Dimensions Weight H x W x D (mm) (kg) 1740 x 600 x 380 283 2000 x 600 x 500 476 2000 x 600 x 500 476 2000 x 600 x 500 498

*Measured at balanced grid without pre-distortion and with VLT® drive matching full load demand

June 2012 - Prices may change without notification

105

VARIABLE SPEED DRIVES & SOFT STARTERS

VLT® Advanced Harmonic Filter Optimised harmonic performance with the VLT® FC series up to 250 kW. The Danfoss Advanced Harmonic Filters have been specially designed to match the Danfoss frequency converters for unmatched performance and design. Compared to traditional harmonic trap filters they offer a smaller foot print and higher harmonic reduction. The solution is available in two variants, AHF 005 and AHF 010. When connected in front of a Danfoss VLT® frequency converter, the harmonic current distortion generated back to the mains is reduced to 5% and 10% Total Harmonic Current Distortion at full load. With a >98% efficiency the passive Advanced Harmonic Filters offer cost effective and very robust harmonic solutions specifically for power up to 250 kW. Filter current ➤ 10 A – 480 A (380 – 415 V, 50/60 Hz) ➤ 10 A – 436 A (440 – 480 V, 60 Hz) ➤ (Modules can be paralleled for higher power)

Line voltage ➤ 380 – 415 V AC (50 and 60 Hz) ➤ 440 – 480 V AC (60 Hz) ➤ 500 – 525 V (50 Hz)* ➤ 690 V (50 Hz)*

Enclosure degree ➤ IP 20/IP 00

*Existing range. Will be upgraded and released 3rd Quarter 2010.

Options The following options are available: IP21/NEMA 1 kit

Feature

Benefit

Reliable

Maximum Uptime

100% factory tested Based on proven and tested filter concept

Low failure rate

Energy saving

Lower operation costs

High efficiency Electrically matched to the individual VLT® FC drives

Low running expenses

Design

Compact and aesthetic enclosure

Innovative coil design Side-by-side mounting Optimized for mounting in panels

Smaller footprint Less wall space needed

Easy commissioning

Low commissioning costs

Enclosure size and colour matches

Danfoss look and feel

PC software VLT® MCT 10 Setup Software VLT® MCT 10 offers advanced programming functionality for all Danfoss drive products, greatly reducing programming and set-up time. VLT® MCT 31 Harmonics Calculation Software With VLT® MCT 31, you can determine whether harmonics will be an issue in your installation when drives are added.

Specifications THiD* at: – 40% load – 70% load – 100% load

AHF 010

AHF 005

~12% ~11%