Control Gear & Switch Gear

farnell.com element14.com 2805 Control Gear & Switch Gear Page 22mm Switches ABB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Author: Amy Martin
79 downloads 0 Views 6MB Size
farnell.com

element14.com

2805

Control Gear & Switch Gear Page 22mm Switches ABB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Moeller RMQ Titan . . . . . . . . . . . . . . . . . . . . . . . Telemecanique Harmony ZB4 Metal Bodies . . . . . . . . . . . . . . . . . . . . . . . . Telemecanique Harmony ZB4/ZB5 Accessories . . . . . . . . . . . . . . . . . . . . Telemecanique Harmony ZB5 Double Insulated . . . . . . . . . . . . . . . . . . . . 30mm Switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Breakers/Motor Starters . . . . . . . . . . . . . Contactors ABB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

IMO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2816 2834 Rockwell MCS Series . . . . . . . . . . . . . . . . . . . . 2805 2836 Telemecanique K Series . . . . . . . . . . . . . . . . . . 2810 2833 Telemecanique Tesys Series. . . . . . . . . . . . . . 2806 2831 Control Pendants . . . . . . . . . . . . . . . . . . . . . . . . . . 2838 Control Stations, Enclosures and Emergency Stops 2828 Moeller. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2838 Telemecanique . . . . . . . . . . . . . . . . . . . . . . . . . . 2837 2831 Enclosures and Emergency Stops IMO/Rockwell/MTE. . . . . . . . . . . . . . . . . . . . . . . 2838 2830 Mains Isolators . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2824 2839 Rotary Cam Switches . . . . . . . . . . . . . . . . . . . . . . 2823 2822 Solid State Contactors . . . . . . . . . . . . . . . . . . . . . 2820 Suppressors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2822 2817

Contactors - Rockwell MCS Series

Control Relays, 4 pole

Ì Ultra compact construction designed to reduce panel space (up to 18.5kW = 45mm wide) Ì Terminal finger protection, IP2LX Ì Surface or DIN rail mounting Ì In built auxiliary contacts (1 N/O on 4kW - 11kW) Ì Reversible coil connections Ì Electronic timers which snap directly onto contactor coil

Current Rating AC1 AC3 32A 9A 32A 9A 32A 9A 32A 12A 32A 12A 32A 12A 32A 12A

Mftrs. List No. 100-C09KD10 100-C09KA10 100-C09DJ10 100-C12KJ10 100-C12KD10 100-C12KA10 100-C12DJ10

Order Code 717-2205 717-2217 722-0868 717-2229 717-2230 717-2242 722-0870

Current Rating AC1 AC3 32A 16A 32A 16A 32A 16A 32A 23A 32A 23A 100A 85A

Mftrs. List No. 100-C16KD10 100-C16KA10 100-C16DJ10 100-C23KA10 100-C23DJ10 100-C85KA00

205729

Mftrs. Control

Order Code 717-2266 717-2278 722-0881 717-2308 722-0893 717-2497 205727

Control

Mftrs.

Voltage

List No.

Price Each

List No.

Order Code

2 N/O +2 N/C 230V ac

700-CF220KA

717-2618

24V dc

700-CF220DJ

722-0960

3 N/O +1 N/C 230V ac

700-CF310KA

717-2588

4 N/O 230V ac 24V dc

700-CF400KA 700-CF400DJ

717-2552 722-0984

1+

5+

10+

Price Each Order Code

1+

5+

10+

Auxiliary Contacts

35

Front & Side-Mounted

9A, 4kW (AC3) 110V ac 100-C09KD10

717-2205

240V ac 24V dc

100-C09KA10 100-C09DJ10

717-2217 722-0868

12A, 5.5kW (AC3) 24V ac 100-C12KJ10 110V ac 100-C12KD10 240V ac 100-C12KA10 24V dc 100-C12DJ10

717-2229 717-2230 717-2242 722-0870

16A, 7.5kW (AC3) 110V ac 100-C16KD10 240V ac 100-C16KA10 24V dc 100-C16DJ10

717-2266 717-2278 722-0881

23A, 11kW (AC3) 240V ac 100-C23KA10 24V dc 100-C23DJ10

717-2308 722-0893

85A, 45kW (AC3) 240V ac 100-C85KA00

DC Control Relays Ì Footprint identical as the AC devices Ì Common accessories as per AC devices Ì Low coil consumption Ì Reversible coil connections - (top or bottom to suit control wiring) Ì In-built diode surge suppression as standard throughout Ì Direct PLC control Ì Contacts designed for switching low voltage/low current requirements as per DIN 1924 (17V 5mA & >10 8 operations per error).

Control Gear & Switch Gear

Ì Positively-guided contacts Ì 2 separate cable chambers from 15kW allow different cable sizes Ì Standards: CE, CSA, IEC947, EN60 947, VDE 0660, UL 508, CSA22.2 D.C. contactors and UL Recognised Ì Common accessories as per AC devices Ì Low coil consumption Ì Reversible coil connections - (Top or bottom to suit control wiring) Ì In-built diode surge suppression as standard throughout

Dimensions: H = 80.5, W = 45, D = 81

Ì High contact reliability Ì Uses same accessories as contactor range Ì Available as 2 N/O+2 N/C, 3 N/O+ 1N/C, and 4 N/O variants Ì Rated insulation voltage: 690V Ì Contact rating: 25A@40°C AC-1

Automation

Contactors

717-2497

Ì Common through all contactor and relay range Ì Available in both front and side-mounting versions Ì Contacts can be snap-fitted to all contactors and relays without additional tools Ì Side-mounted contacts available in single or double-pole types and can be used on both sides of the contactors/relay Ì Front-mounting contacts available in 2 or 4-pole Ì Up to 8 contacts can be mounted, a maximum of 4 N/C contacts on the front and 2 N/O contacts each side Ì Number of blocks per contactor/relay: 2 side + 1 front (Max. 8 contacts) Ì All contacts positively-guided Ì Current rating: 10A@40°C AC-1 Ì Contacts are cross stamped, enabling reliable switching at 10A@AC-1 and at 17V, 5mA, as per DIN 19240 205730

Front

Mftrs.

Price Each

Mounting

List No.

2 Pole 1NO / 1NC

100-FA11

717-2679

4 Pole 2NO / 2NC 3NO / 1NC

100-FA22 100-FA31

717-2680 717-2692

Side Mounting 1NO / 1NC 100-SB11

717-2722

Order Code

1+

5+

10+

2805

2806

farnell.com

Contactors - Rockwell MCS Series continued

TeSys AC Contactors 4 Pole Ì Compact width of 45mm (up to 40 amp AC1) Ì 4 normally open or Ì 2 normally open and 2 normally closed versions Ì 2 auxiliary contacts as standard Ì Wide range of auxiliaries common to TeSys 3 pole offer Ì Conforms to international standards and approvals

Electronic Overloads

Ì Ì Ì Ì Ì

Ì Electronic overload suitable for all standard 3 phase motors Ì Provides higher levels of motor protection for the cost of a standard thermal overload Ì Wired as conventional overloads, self-powered and requires no additional power supply Ì Manual reset Ì Continuous temperature compensated Ì On board contacts, 1 N/O +1 N/C Manual test facility and visual trip indicator aids panel testing and fault finding Single-phase protection within 2 secs, eliminating heat build-up within motor and possible damage Wide adjustment range reduces number of overloads required In-built current transformers reduce energy consumed compared to conventional thermal overloads, typically 150mW Tripping class 10

LC1D Contactors with AC Coil Type H DT20 - DT25 85 DT40 91 D80004 127

Mftrs.

Range A

List No.

3.7 to 12 12 to 32

193-ED1DB 193-ED1EB

1+

5+

Coil Consumption in VA Sealed 7.5 7.5 26

Ratings Based On Ambient of 60°C Coil Voltage 50/60Hz

10+

717-2916 717-2928

Mftrs. List No.

Inrush 70 70 245

Price Each Order Code

1+

5+

10+

AC1 - 4 NO Contacts

24V

20A LC1DT20B7

423-1855

110V 230V

LC1DT20F7 LC1DT20P7

423-1867 423-1879

25A 24V 110V 230V

Contactors - Telemecanique Tesys Series Automation

TeSys AC Contactors AC Coils - 50/60Hz

D 90 98 125

247932

Price Each Order Code

W 45 45 96

Contactors with AC Coil 50/60Hz

205737

Adjustment

element14.com

LC1DT25B7 LC1DT25F7 LC1DT25P7

423-1910 423-1922 423-1934

40A 24V 110V 230V

Ì 1 NO and 1 NC auxiliary contact built in Ì NC auxiliary contact mechanically linked to power poles for use in safety circuits (Mirror contact) Ì Snap-on safety cover supplied as standard Ì Separation of control and power for simplified wiring Ì DIN Rail or screw fixing, finger protection Ì Confirms to international standards and approvals

LC1DT40B7 LC1DT40F7 LC1DT40P7

423-1946 423-1958 423-1960

60A 230V

LC1D40004P7

423-1983

230V

125A LC1D80004P7

423-2021

624293

Ratings based on ambient temperature of 60°C

35

2 NO + 2 NC Contacts

Price Each

Control Gear & Switch Gear

Coil Voltage

Mftrs. List No.

Order Code

kW/415V

AC3

4kW 24V

9A LC1D09B7

362-2046

110V 230V 400V

LC1D09F7 LC1D09P7 LC1D09V7

362-2058 362-2060 362-2071

5.5kW 24V 110V 230V 400V

12A LC1D12B7 LC1D12F7 LC1D12P7 LC1D12V7

362-2083 362-2095 362-2101 362-2113

9kW 24V 110V 230V

18A LC1D18B7 LC1D18F7 LC1D18P7

362-2125 362-2137 362-2149

11kW 24V 110V 230V

25A LC1D25B7 LC1D25F7 LC1D25P7

362-2162 362-2174 362-2186

15kW 24V 110V 230V 400V

32A LC1D32B7 LC1D32F7 LC1D32P7 LC1D32V7

362-2204 362-2216 362-2228 362-2230

18.5kW 24V 110V 230V

38A LC1D38B7 LC1D38F7 LC1D38P7

362-2241 362-2253 362-2265

22kW 24V 110V 230V

40A LC1D40B7 LC1D40F7 LC1D40P7

362-2289 362-2290 362-2307

30kW 24V 230V

50A LC1D50B7 LC1D50P7

362-2320 362-2344

37kW 110V 230V

65A LC1D65F7 LC1D65P7

362-2370 362-2381

45kW 230V

80A LC1D80P7

362-2411

1+

5+

110V

20A LC1D098F7

423-1892

230V

LC1D098P7

423-1909

230V

25A LC1D128P7

423-2057

230V

40A LC1D258P7

423-2082

10+

TeSys DC Contactors with Low Power Consumption Coil

Ì High performance in compact housing >

LAD7B106

790-5734

LA7D3064

214-413

TeSys Control Relays Ì Supplied with 5 auxiliary contacts as standard Ì N/O and N/C contacts are mechanically linked Ì DC coil version only 9mm deeper than AC version Ì DC version wide range coil (Uc 0.7 to 1.25) and built-in coil suppression as standard Ì Standard features DIN rail or screw fixing, finger protection etc. Ì Conforms to international standards and approvals Ì Accepts full range of accessories from the TeSys offer Dimensions CAD AC Coil DC Coil

For use with TeSys contactors