CommScope-APC Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center ORDERING GUIDE 1ST EDITION

CommScope-APC® Integrated Cisco Data Center Solutions Advanced Infrastructure Solution for Cisco Data Center 3.0 2015 O RDERIN G GU IDE | 1ST ED ITI...
Author: Merilyn Cooper
2 downloads 0 Views 7MB Size
CommScope-APC® Integrated Cisco Data Center Solutions

Advanced Infrastructure Solution for Cisco Data Center 3.0

2015 O RDERIN G GU IDE | 1ST ED ITION

CommScope-APC® Integrated Cisco Data Center Solutions

The evolution of data centers is happening before our eyes. This is due to the increased demand for bandwidth and storage requirements, as well as, consolidation and facility usage due to energy costs. In addition, new technologies such as Storage Area Networks, Blade Servers, Fiber Channel over Ethernet and IP Convergence are driving much of the evolution. Data centers face many challenges including density, reliability, scalability and power consumption. The amount of power required for data centers has doubled in the past five years and is expected to continue to rise in the coming years. One simple way to reduce the power and cooling costs within a data center is to promote proper airflow. Strategies such as implementing hot aisles and proper cable management can go along way towards reducing these costs and creating a more energy efficient data center.

CommScope-APC® Alliance CommScope, a global leader in copper and fiber connectivity and cable management infrastructure solutions, and APC®, an industry leader in critical power and cooling services, have teamed up to provide a complete solution that addresses high density connectivity and management needs, as well as, power and cooling solutions required by today’s complex data center environments.

CommScope-APC® Integrated Data Center Solutions The two companies have collaborated to simplify the data center design decisions, ease the installation process of new equipment and ensure a more efficient and economical data center. The result is an integrated solution that provides superior cable management, scalability in dense environments and industry leading power and cooling options for today’s robust data center environments. Simply choose your active gear and let CommScope and APC take care of the rest. • Electrical distribution and industrial control • Power distribution • Cooling solutions • IT infrastructure management • Fiber and copper connectivity • EF&I services

Benefits of the Integrated Data Center Solutions CommScope-APC Integrated Cisco Data Center Solutions, NetShelter MDS 9513 System, NetShelter MDS 9509 System, NetShelter Catalyst 6509 System offer in-cabinet solutions, for three leading Cisco switches. All three solutions offer the following features:

Data Center Soluions with leading cable management improved airflow, and easy to remove power supply.

• Best-in-class cable management for easy adds, moves and changes • Improved air-flow and energy efficiency within your data center • Ease of installation

3

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions Airflow and Cooling Management

The CommScope-APC® Integrated Data Center Solutions offer answers to the problems of cooling, airflow and cable management within your data center. The primary goal of thermal management and power management in the data center is to maximize the performance, uptime and life expectancy of the active equipment used by your enterprise. This goal is accomplished by managing the cold air delivered to every piece of equipment such that the internal temperature of all equipment in the data center never exceeds the manufacturer’s maximum allowable operating temperature. Two easy and effective approaches are designing your data center with hot aisles and cold aisles and using products and solutions that maximize cable management and airflow around equipment. The hot and cold aisle arrangement provides the most efficient means for IT equipment in a data center with traditional front-to-back airflow. Equipment with side-to-side airflow, common with many large, data center switches, presents some additional cooling challenges within an enclosure. The typical solution for side-to-side airflow switches is to direct the air to essentially convert the equipment to intake and exhaust air from the front and rear of the enclosure. The CommScope-APC® solution offers side airflow ducts to direct the cool air at the front of the enclosure, directly and predictably to the intake at the side of the switch. The Side Airflow Duct Kit shown below, consists of two 2U ducts that act as diverters utilizing the existing fan power of the switch. A baffle is located on the back of the switch and ducts to mitigate exhaust air from recirculating back into the air intake. The exhaust air from the equipment then exits from the rear of the rack with no opportunity to return to the equipment air intake. Proper use of blanking panels in conjunction with the APC NetShelter enclosure restricts any hot air from entering into the cold aisle. This, in essence, allows the cooling pattern for side-to-side equipment to become front-to-back thereby integrating seamlessly with other equipment in enclosures.

AR7715X900 Side Airflow Duct Kit shown with Cisco 6500 series switch

4

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions Cisco Equipment

The CommScope-APC Integrated Cisco Data Center Solutions have been design around three industry leading Cisco switches, the 9509, 9513, and 6509. Simply choose your active gear and let CommScope and APC take care of the rest.

Cisco MDS 9509 The Cisco 9509 Series provides industry-leading availability, scalability, security, and management. The Cisco MDS 9509 allows you to deploy highperformance storage-area networks (SANs) with lowest total cost of ownership.

Cisco MDS 9509

Cisco MDS 9513 The Cisco MDS 9513 Multilayer Director elevates the standard for directorclass switches. Providing industry-leading availability, scalability, security, and management, the Cisco MDS 9513 allows you to deploy high-performance SANs with an extremely low total cost of ownership. Cisco MDS 9513

Cisco MDS 6509 The Cisco Catalyst 6500 Series of enhanced (E-Series) switches, includes a chassis with up to 1440 Gbps of system bandwidth capacity (80 Gbps/slot), Cisco Catalyst 6500 E-Series chassis provide superior investment protection by supporting multiple generations of products on the same chassis, lowering the total cost of ownership. Cisco MDS 6509

5

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions APC Enclosure and Accessories

NetShelter® SX 42U 750 mm Wide x 1070 mm Deep Enclosure feature-rich rack enclosures with advanced cooling, power distribution, and cable management for server and networking applications in IT environments. APC’s NetShelter SX enclosures offer the most standard, out-of-the-box features to ease installation and speed deployment. The SX utilizes a single, flexible enclosure design to accommodate various networking and server applications. Seamless integration with APC InfraStruXure products such as power distribution, in-row cooling and uninterruptible power supplies provides the building blocks for any data center.

Features • Cable Access Roof • Half-height side panels • Easy adjustable vertical mounting rails • Integrated Rear cable channels for toolless mounting of PDUs and cable managers • Leveling feet and castors • Wider for more cable management and improved rear access • Ventilated Perforated front and rear doors provide ample ventilation APC's NetShelter SX Enclosure and Power Supply

NetShelter MDS 9513 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7864 Rack mount PDUs for Dual Cisco 6000W power supplies Cooling: AR7715X900 Side Airflow Duct Kit

NetShelter MDS 9509 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7841 Rack mount PDUs for Dual Cisco 3000 W power supplies Cooling: AR7715X900 Side Airflow Duct Kit

NetShelter Catalyst 6509 System Enclosure, Cooling, and Power Components: Enclosure: AR3150 NetShelter SX Enclosure (42U x 750 mm W x 1070 mm D) Power Distribution Unit: (2) AP7864 Rack mount PDUs for Dual Cisco 6000 W power supplies. For 8700W power supplies use (2) AP7868 Cooling: AR7715X900 Side Airflow Duct Kit

Side Airflow Duct Kit Designed for optimal cooling for Cisco side-ventilating switches, the kit includes a top and bottom (2) U duct, (2) mounting zero U mounting brackets, rear isolation baffle, hardware, and an installation sheet.

6

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions CommScope Connectivity and Cable Management

CommScope’s Structured Cabling System is an end-to-end, integrated portfolio of high-performance copper and fiber cable, connectivity and cable management solutions. The following connectivity and cable management components are designed specifically for each of the NetShelter solutions.

NetShelter MDS 9513 System Connectivity and Cable Management Components:

(1) (1) (1) (1) (1) (2) (4)

Rear Cable Manager Vertical Slack Storage Panel Storage Panel Vertical Cable Guide Cross-through Trough Horizontal Slack Storage Panel 2 RU Blank Plate Fiber Panel with New Cable Manager, 5 RU

This kit does not include the patch cords, cassettes or adapters plates that go into the Fiber Panels.

NetShelter MDS 9509 System Connectivity and Cable Management Components:

(1) (1) (1) (1) (1) (2) (1) (3)

Rear Cable Manager Vertical Slack Storage Panel Vertical Cable Guide Cross Through Trough Horizontal Slack Storage Panel 2 RU Blank Plate 5 RU Blank Plate Fiber Panel with New Cable Manager, 5 RU

NetShelter MDS 9513 System

This kit does not include the patch cords, cassettes or adapters plates that go into the Fiber Panels. CommScope‘s 5 RU Fiber Panel

NetShelter Catalyst 6509 System Connectivity and Cable Management Components:

(2) (7) (3) (1) (1) (1) (2) (2) (7)

Rear Cable Manager Cable Ring Fiber Bracket Convoluted Tubing Vertical Cable Guide Crossover Trough Horizontal Slack Storage Panel 2 RU Blank Panel Category 6 Patch Panel and Cable Bars

CommScope‘s Category 6 Dynamic Angled Patch Panel

This kit does not include the patch cords.

7

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions How to Cable the Solutions

Your network equipment can only perform as well as your cables. Cabling within the data center should be deployed with proper bend radius protection, well-defined cable routing paths, room to work on connectors and cables without affecting adjacent circuits or ports, and physical protection for equipment cables. Without proper management, problems can arise and lead to increased time required to decommission hardware and bring new hardware online or inefficiencies in the cooling of the data center. The CommScope-APC Integrated Data Center Solutions take the guess work out of cable management with intuitive cable routing and the ease of using a single length of patch cord throughout. CommSope-APC Integrated Data Center Solutions are designed for a speedy deployment. When installing a patch cord, first connect it to the active equipment, and then connect it to the patch panel, then route the patch cord appropriately through the cable guides. Refer to the diagrams below for illustrations on how to cable all three of the CommScope-APC Integrated Data Center Solutions.

How to Cable the NetShelter MDS 9513 System

3M patch cords routed on left side of cabinet

D1

D2

C1

C2

B1

B2

A1

A2

D1

D2

C1

C2

B1

B2

A1

A2

Top Entry

Cables can enter enclosure from top or bottom.

Bottom Entry

2M patch cords routed on right side of cabinet

23405-A

23401-A

8

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions How to Cable the Solutions

How to Cable the NetShelter MDS 9509 System

3M Patch Cords Routed on Left Side of Cabinet

C1

C2

B1

B2

A1

A2

Cables can enter enclosure from top or bottom.

Top Entry

C1

C2

B1

B2

A1

A2

Bottom Entry

2M Patch Cords Routed on Right Side of Cabinet

23406-A

23402-A

NetShelter Catalyst 6509 System

B4 B3 B2

Top Entry

B1

Cables can enter Enclosure from Top or bottom.

A3 A2 A1

Bottom Entry 7-foot

B4 B3 B2 B1 A1 A2 A3

11-foot

23454-A

23453-A

9

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions Integrated Solutions – Ordering Information

Below is the ordering information for the CommScope-APC Integrated Cisco Data Center Solutions. Choose the connectivity and cable management solution that corresponds to the Cisco equipment selected. All three kits coordinate with the APC NetShelter SX 42U enclosure. For Cisco equipment, please order through the proper channels.

Ordering Information Description

Catalog Number

Enclosure, Cooling, and Power – APC NetShelter SX, 42U x 750mm wide x 1070mm deep enclosure

AR3150

Side Airflow Duct Kit for 6509, 9509, 9513

AR7715X900

Power Distribution Unit for MDS 9513 with 6000W PS

AP7864

Power Distribution Unit for MDS 9509 with 3000W PS

AP7841

Power Distribution Unit for Catalyst 6509 with 6000W PS

AP7864

Power Distribution Unit for Catalyst 6509 with 8700W PS

AP7868

Connectivity and Cable Management – CommScope MDS 9513 system connectivity and cable management kit

C9D1FT04

MDS 9509 system connectivity and cable management kit

C991FT03

Catalyst 6509 system connectivity and cable management kit

C691C607

10

For more information, visit commscope.com

CommScope-APC® Integrated Cisco Data Center Solutions Accessories – Ordering Information

The following items can be ordered separately to support the CommScope-APC Integrated Cisco Data Center Solutions:

Ordering Information Description

Catalog Number

NetShelter MDS 9513 and 9509 Systems Multimode Adapter only Packs; LC adapters with zirconia sleeve, aqua color, 12 adapters or 24 fiber ports per adapter pack

Angle LEFT adapter only pack

TFP-24APLQ2

Angle RIGHT adapter only pack

TFP-24APRQ2

Singlemode Adapter Packs; LC adapters with zirconia sleeve, blue color, 12 adapters or 24 fiber ports per adapter pack

Angle LEFT adapter only pack

TFP-24APLQ5

Angle RIGHT adapter only pack

TFP-24APRQ5

MPO Adapter Pack; Contains 6 MPO adapters, can be installed in either left or right position Fiber Patch Cords

TFP-72AP0MP

Length of ZipCord

2 mm zipcord 50/125 multimode – 150 meters @ 10 Gigabit; LC-LC connectors 1.6 mm zipcord

2 mm zipcord 50/125 multimode – 300 meters @ 10 Gigabit; LC-LC connectors 1.6 mm zipcord

2 mm zipcord Singlemode; LC-LC connectors 1.7 mm zipcord

Length of Patch Cord

Catalog Number

2 meters

PAT-LM5EQ-002MPT

3 meters

PAT-LM5EQ-003MPT

2 meters

PAT-LM5EV-002MPT

3 meters

PAT-LM5EV-003MPT

2 meters

PAT-LM5UQ-002MPT

3 meters

PAT-LM5UQ-003MPT

2 meters

PAT-LM5UV-002MPT

3 meters

PAT-LM5UV-003MPT

2 meters

FPC2E-SDLC-2M

3 meters

FPC2E-SDLC-3M

2 meters

FPCTE-SDLC-S-2M

3 meters

FPCTE-SDLC-S-3M

NetShelter Catalyst 6509 System 568B CopperTen Category 6A RJ45-RJ45 UTP patch cord 568A

T568B

Category 6 RJ45-RJ45 plug UTP PVC patch cord

T568A

crossover

11

7 feet

6645-2-8X5-07

11 feet

6645-2-8X5-11

7 feet

6645-2-8X0-07

11 feet

6645-2-8X0-11

7 feet

6645-2-78X-07

11 feet

6645-2-78X-11

7 feet

6645-2-77X-07

11 feet

6645-2-77X-11

7 feet

6645-2-79X-07

11 feet

6645-2-79X-11

For more information, visit commscope.com

www.commscope.com Visit our website or contact your local CommScope representative for more information. © 2015 CommScope, Inc. All rights reserved. All trademarks identified by ® or ™ are registered trademarks or trademarks, respectively, of CommScope, Inc. This document is for planning purposes only and is not intended to modify or supplement any specifications or warranties relating to CommScope products or services. CA-107947.1-AE (11/15)