Commercial Water Heaters

Commercial Water Heaters www.johnwoodwaterheaters.com Table of Contents The John Wood Philosophy 3 Tankless Water Heaters 4 Electric Water Heaters ...
Author: Derek McDowell
1 downloads 1 Views 8MB Size
Commercial Water Heaters

www.johnwoodwaterheaters.com

Table of Contents The John Wood Philosophy 3 Tankless Water Heaters 4 Electric Water Heaters 5 High-Efficiency Modulating Gas Water Heaters 7 Polaris® High-Efficiency Gas Water Heaters 9 Atmospheric Vent Water Heaters 11 Storage Tanks 13 Oil-Fired Water Heaters 14 Light Duty Atmospheric Water Heaters 15 Exclusive Designs, Built-to-Last 16 Service & Support 16 Sample Specifications 17

The John Wood® Philosophy When you buy a John Wood water heater, you buy a quality dependable product. John Wood support is based on First Call, Final Resolution service. Our Care Technicians are driven to provide expert guidance to identify the issue quickly and assist you until you’re satisfied.

Support is available 24/7 with online resources, such as Online Parts Catalogue, Warranty Validation and Product Information.

3

www.johnwoodwaterheaters.com

John Wood® Commercial Tankless Water Heaters John Wood powered by Takagi commercial models offer important factors for any commercial organization or business: saving space, energy and money. Offering light duty models for lessdemanding commercial applications to robust models to suit the most challenging of applications. Features • Tankless water heaters only activate when hot water is being used - therefore no standby energy losses are incurred, providing efficient heating and conserving gas energy • Condensation-reducing design to prevent premature failure of the heat exchanger from excess condensate • Models feature multiple unit installation of up to 4 units with no additional accessories and up to 20 units with TM-MC02 system controller (except JWT-510) • Heat exchanger manufactured with HRS35 commercial-grade heat-resistant copper alloy that has 8 times more tensile strength than regular copper ensuring its longevity and 25 times the heat transfer rate than stainless steel • Drums that are 25% thicker, ensuring the longevity of the water heater - a thicker drum creates less strain on the heat exchanger • Can be installed as a Direct Vent with the purchase of a Direct Vent Conversion Kit (with MODEL SPECIFICATIONS exception of condensing models) Input BTU/h Hot Water Output (GPM) Model Energy Factor/ Thermal Efficiency • Air-Fuel Ratio (AFR) Sensor, unique to these models, Number * Minimum Maximum 30°F Rise 70°F Rise maintains proper combustion at all times JWT-540H-DV-N 13,000 199,000 0.95 10.0 5.4 JWT-510-N 11,000 199,000 0.83 (NG) 0.82 (LP) 10.0 4.7 • Overheat cutoff fuse JWT-710-N 24,000 240,000 82.2% (NG) 83.9% (LP) 9.0 5.5 • Dual internal freeze protection JWT-910-N 15,000 380,000 80.2% (NG) 82.4% (LP) 14.5 8.7 *For propane, change N to P in the model number when ordering. Example: JWT-710-P. • Manual hi-limit switch • Components are easily accessible within unit for trouble-free maintenance

Options • Complete line of venting and accessories available 10 year heat exchanger warranty, 5 years on parts

4

Electric Water Heaters John Wood® electric water heaters are an advanced line of commercial water heaters with the features contractors and engineers have told us they require. Custom built to order in three sizes: 50, 80 and 119 US gallons and inputs from 6 to 54 kW. Voltages available are 208, 240 and 600. † Features • Meets or exceeds ASHRAE Efficiency Standard 90.1 • Gold-plated, long-life elements provide superior scaling resistance • Glasslined tank rated at 150 psi (working pressure) • Factory-installed terminal block allows for quick connection

ELECTRONIC CONTROL NOT AVAILABLE ON JW-ES MODELS

• Power circuit fusing protects elements and contactors from short circuits, overloading or line surges • Three standard voltages available - convertible in the field from three-phase to single-phase (except 208/54kW models) • JW-EI models feature an advanced electronic control - displays operational and diagnostic information and has economy mode option for off-peak or unoccupied periods

JW-EI Model shown

• ASME T&P relief valve included with unit for field installation • Equipped with multiple anode rods for longer life • Brass drain valve

Options • Surface or immersion thermostat for automatic temperature control

3 year inner tank warranty, 1 year on parts.

5

www.johnwoodwaterheaters.com

† certain exceptions apply

John Wood® Commercial Configuring Your Model: 1. Select surface thermostat (ES) or immersion thermostat (EI) 2. Select size (50, 80 or 119 US gallons) 3. Select input from 6 to 54 kW** 4. Select voltage: 208, 240 or 600* 5. Select phase 1 or 3 JW-EI-80-450-240-1 is an 80 U.S. Gallon, 45 kW, 240 volt, 1 phase model with an Immersion Thermostat.

CONFIGURE YOUR MODEL

kW Power Input Volts

JW-E(S/I)-50 50 US gallon

JW-E(S/I)-80 80 US gallon

JW-E(S/I)-119 119 US gallon

6-54**

6-54 208, 240, or 600*

6-54

DIMENSIONS Capacity

Installation Height

Tank Diameter

Overall Depth

Inlet/ Outlet NPT

Approximate Shipping Weight

USG/L

A IN/CM

B IN/CM

C IN/CM

IN/CM

LBS/KG

50 / 189 80 /303 119/ 450

55 3/4 / 142 60 1/4 / 153 62 1/4 / 158

21 3/4 / 55 25 1/2 / 65 29 1/2 / 75

27 / 69 31 / 79 35 / 89

1 1/4 / 3 1 1/4 / 3 1 1/4 / 3

265 / 120 280 / 127 390 / 177

Model

JW-E(S/I)-50 JW-E(S/I)-80 JW-E(S/I)-119

RECOVERY

Standard kW Input

BTU/h

6 9 12 13.5 15 18 24 27 30 36 40.5 45 54

20,478 30,717 40,956 46,075 51,195 61,434 81,912 92,151 102,390 122,868 138,226 153,585 184,302

Recovery Rate in Gallons per Hour

Recovery Rate in Litres per Hour

Temperature Rise in °F

Temperature Rise in °C

40°F

60°F

80°F

100°F

120°F

140°F

22°C

33°C

44°C

56°C

67°C

78°C

62 92 123 138 154 184 246 276 307 369 418 461 554

41 62 82 92 102 123 164 185 205 246 277 307 359

31 46 61 69 77 92 123 138 154 184 208 230 277

25 37 49 55 61 74 98 111 123 148 166 184 221

21 31 41 46 51 61 82 92 102 123 138 154 185

18 26 35 40 44 53 70 79 88 105 119 132 158

233 349 466 523 582 698 930 1047 1163 1396 1570 1745 2094

155 233 310 349 388 465 620 609 775 930 1047 1163 1396

116 174 231 262 291 349 465 523 582 698 785 872 1047

93 140 185 209 233 279 372 410 465 556 628 698 837

78 116 155 174 194 233 310 340 388 465 582 582 697

66 100 132 150 166 199 266 299 332 399 450 498 598

ELECTRICAL CHARACTERISTICS kW Power Input 6 9 12 13.5 15 18 24 27 30 36 40.5 45 54

Full Load Current in Amperes Number of Elements 3 3 3 3 3 3*** 6 6 6 6*** 9 9 9

Element Wattage 2000 3000 4000 4500 5000 6000 4000 4500 5000 6000 4500 5000 6000

208 Volts 1 Phase 29 43 58 65 72 87 115 130 144 173 195 216 N/A

240 Volts 3 Phase 17 25 33 38 42 50 67 75 83 100 112 125 150

1 Phase 25 38 50 56 63 75 100 113 125 150 169 188 225

600 Volts 3 Phase 15 22 29 33 36 43 58 65 72 87 97 108 130

3 Phase 6 9 12 13 14 17 23 26 29 35 39 43 52

* 600 Volt available only in 3 Phase. ** 40.5 kW, 45 kW and 54 kW inputs not available for JW-ES-50 *** 208V models use 3 additional elements.

6

High-Efficiency Modulating Gas Water Heater John Wood® commercial high-efficiency modulating gas water heaters are designed for outstanding reliability and excellent thermal efficiency. Compared to standard commercial water heaters, these models deliver higher rated thermal efficiencies up to 98%. Features • Fully submerged, spiral-shaped condensing heat exchanger to maximize heat transfer, provide high efficiency, and avoid sediment buildup on the heat exchanger surface • Adjusts firing rate to the specific demand, increasing efficiency and money savings • ENERGY STAR® qualified • Down-fired pre-mix powered burner provides optimum efficiency and quiet operation • Robust direct spark ignition for years of worry free operation • Top mounted controls (gas valve, combustion air blower) for easy access during installation and service • Advanced control system provides detailed status information including diagnostics and run history information as well as precise temperature control adjustment from 90°F (32°C) to 180°F (82°C) • User-friendly LCD display shows all operating settings for ease of use • Powered anodes: two titanium powered anodes provide superior tank protection in varying water conditions • Flexible venting options: standard power vent or power direct vent flexibility, in vertical or sidewall configurations, using ULC S636 PVC, CPVC, polypropylene or AL29-4C® stainless steel pipe in runs of up to 115 feet depending upon vent pipe size • Commercial grade glass-lined tank and heat exchanger provide long-term protection against corrosive water, flue gases and condensate

ASME (Optional)

RECOVERY CAPACITIES

Model

Input Rate BTU/h (kW)

Fuel Type

Thermal Efficiency

Gas Line Size N.P.T.

Approx. Tank Capacity Gallons (Litres)

°F - GALLONS °C - (LITRES) 30°F (17°C)

40°F (22°C)

50°F (28°C)

60°F (33°C)

70°F (39°C)

80°F (45°C)

90°F (50°C)

150,000 100 576 432 345 288 247 216 192 NG/LP 98% ¾" (44) (379) (2179) (1635) (1308) (1090) (934) (817) (726) 199,900 100 767 575 460 384 329 288 256 (A)JWSH100-199 NG/LP 97% ¾" (58) (379) (2904) (2178) (1743) (1452) (1245) (1089) (968) 250,000 100 960 720 576 480 411 360 320 (A)JWSH100-250 NG/LP 96% ¾" (73) (379) (3632) (2724) (2179) (1816) (1557) (1362) (1211) 300,000 119 1164 873 698 582 499 436 388 AJWSH119-300 NG/LP 96% 1½" (88) (450) (4404) (3303) (2643) (2202) (1888) (1652) (1468) 399,900 119 1535 1151 921 767 658 576 512 AJWSH119-400 NG/LP 95% 1½" (117) (450) (5810) (4357) (3486) (2905) (2490) (2179) (1937) Recovery capacities are based on heater performances at rated thermal efficiency. Add “A” in front of model number when ordering ASME. For example, AJWSH100-199N. N to P when ordering propane (LP). Maximum gas supply pressure for all models: 14”W.C. (3.49 kPa) for natural gas and propane. Manifold pressure: 0”W.C. (0 kPa) for natural gas and propane. Electrical requirements: 120 VAC/60Hz. Blower 2.2 Amps FL. Ignitor 4.0 Amps. AJWSH119-300 and 400 are available in ASME only. (A)JWSH100-150

3 year inner tank warranty, 1 year on parts.

7

www.johnwoodwaterheaters.com

100°F (56°C)

110°F (61°C)

120°F (67°C)

130°F (72°C)

173 (654) 230 (871) 288 (1090) 349 (1322) 460 (1743)

157 (594) 209 (792) 262 (991) 317 (1201) 419 (1585)

144 (545) 192 (726) 240 (908) 291 (1101) 384 (1452)

133 (503) 177 (670) 221 (838) 269 (1016) 354 (1341)

John Wood® Commercial (A)JWSH100-150 thru (A)JWSH100-250

BACK

FRONT

AJWSH119-300 thru AJWSH119-400

FRONT BACK

DIMENSIONS A

B

C

D

E

F

G

H

I

J

Shipping Weight STD

Shipping Weight ASME

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

LBS (KG)

LBS (KG)

(A)JWSH100-150

3 (8)

273/4 (71)

65/16 (16)

563/8 (143)

76 (193)

753/4 (192)

111/4 (29)

64 (163)

70 (178)

181/4 (46)

523 (237)

553 (251)

(A)JWSH100-199

3 (8)

273/4 (71)

65/16 (16)

563/8 (143)

76 (193)

753/4 (192)

111/4 (29)

64 (163)

70 (178)

181/4 (46)

523 (237)

553 (251)

Model

(A)JWSH100-250

3 (8)

273/4 (71)

65/16 (16)

563/8 (143)

76 (193)

753/4 (192)

111/4 (29)

64 (163)

70 (178)

181/4 (46)

523 (237)

553 (251)

AJWSH119-300

43/4 (12)

331/8 (84)

43/4 (12)

52 (132)

753/4 (192)

733/4 (187)

123/4 (32)

631/8 (160)

691/4 (176)

23 (58)

N/A

855 (387)

AJWSH119-400

43/4 (12)

331/8 (84)

43/4 (12)

52 (132)

753/4 (192)

733/4 (187)

123/4 (32)

631/8 (160)

691/4 (176)

23 (58)

N/A

855 (387)

(A)JWSH100-150—(A)JWSH100-250

AJWSH119-300—AJWSH119-400

8

Polaris® High-Efficiency Gas Water Heaters Polaris is the quiet and efficient way to heat water. With a thermal efficiency of 95%–96% and ultra-quiet radial blower and submerged burner, Polaris offers high efficiency and whisper-quiet start-up and operation. Installation and service are easy with all gas valve and blower adjustments factory pre-set and no special adjustments required at initial startup. A self-diagnostic microprocessor monitors nine critical functions and LED trouble-shooting light signals operation status. Features • High grade stainless steel tank with brass connections for years of dependable service—no anode required

• Submerged combustion chamber with spiral flue for 95–96% thermal efficiency and ultra-low standby heat loss

• Woven metal fibre burner of refractory steel resists corrosion, produces low NOx emissions, is resistant to thermal and mechanical shocks and provides even heat distribution through uniform combustion

• Power/Direct Vent up to 120’ using 2” or 3” ULC S636 approved PVC or CPVC • Plug-and-play technology with no special adjustments at initial startup including no adjustments or derating for high-altitude installations

• External temperature adjustment knob up to 185°F • Full serviceability from the front • Modular components are easily removed • Multiple 1” brass tank connections and full flow brass drain valve (side connections for combo heat)

• Factory-installed T&P valve • Zero clearance to combustibles • Design-certified by Underwriters Laboratories Sanitation to NSF Standard 5 for 180°F (82°C) water

Options • Concentric vent kits available for use through the roof or wall

3 year inner tank warranty, 1 year on parts.

9

www.johnwoodwaterheaters.com

John Wood® Commercial

C

CAPACITY & DIMENSIONS Capacity Model

Input BTU/h

USG/L Natural Gas PC130-34-2NV PC130-50-2NV PC175-50-3NV PC199-50-3NV Propane PC130-34-2PV PC130-50-2PV PC175-50-3PV PC199-50-3PV

Height

Height to T&P Valve

Cold Water Inlet**

Gas Inlet

Heating System Inlet**

Heating System Outlet**

Diameter

Shipping Weight

Vent Diameter

A IN / CM

B IN / CM

C IN / CM

D IN / CM

E IN / CM

F IN / CM

G IN / CM

LBS / KG

IN / CM

34 / 129 50 / 189 50 / 189 50 / 189

130,000 130,000 175,000 199,000

48 1/2 / 123 62 1/2 / 159 63 3/4 / 162 63 3/4 / 162

41 / 104 55 / 140 56 1/4 / 143 56 1/4 / 143

15 3/4 / 40 15 3/4 / 40 15 3/4 / 40 15 3/4 / 40

6 1/8 / 16 6 1/8 / 16 6 1/8 / 16 6 1/8 / 16

15 3/4 / 40 15 3/4 / 40 15 3/4 / 40 15 3/4 / 40

40 1/2 / 103 54 1/2 / 138 55 3/4 / 142 55 3/4 / 142

22 / 56 22 / 56 22 / 56 22 / 56

150 / 68 170 / 80 180 / 82 180 / 82

2 or 3 / 5 or 7.5 2 or 3 / 5 or 7.5 3 / 7.5 3 / 7.5

34 / 129 50 / 189 50 / 189 50 / 189

130,000 130,000 175,000 199,000

48 1/2 / 123 62 1/2 / 159 63 3/4 / 162 63 3/4 / 162

41 / 104 55 / 140 56 1/4 / 143 56 1/4 / 143

15 3/4 / 40 15 3/4 / 40 15 3/4 / 40 15 3/4 / 40

6 1/8 / 16 6 1/8 / 16 6 1/8 / 16 6 1/8 / 16

15 3/4 / 40 15 3/4 / 40 15 3/4 / 40 15 3/4 / 40

40 1/2 / 103 54 1/2 / 138 55 3/4 / 142 55 3/4 / 142

22 / 56 22 / 56 22 / 56 22 / 56

150 / 68 170 / 80 180 / 82 180 / 82

2 or 3 / 5 or 7.5 2 or 3 / 5 or 7.5 3 / 7.5 3 / 7.5

** 1” NPT water connections

RECOVERY Model Natural Gas PC130-34-2NV PC130-50-2NV PC175-50-3NV PC199-50-3NV Propane PC130-34-2PV PC130-50-2PV PC175-50-3PV PC199-50-3PV

Recovery in US Gallons per Hour at a Temperature Rise of:

Recovery in Litres per Hour at a Temperature Rise of:

Input BTU/h

40°F

60°F

80°F

100°F

120°F

140°F

15°C

25°C

35°C

45°C

55°C

65°C

130,000 130,000 175,000 199,000

378 378 509 579

252 252 339 386

189 189 255 289

151 151 204 232

126 126 170 193

108 108 145 165

2121 2121 2855 3247

1273 1273 1713 1948

909 909 1224 1391

707 707 952 1082

578 578 779 885

489 489 659 749

130,000 130,000 175,000 199,000

378 378 509 579

252 252 339 386

189 189 255 289

151 151 204 232

126 126 170 193

108 108 145 165

2121 2121 2855 3247

1273 1273 1713 1948

909 909 1224 1391

707 707 952 1082

578 578 779 885

489 489 659 749

10

Atmospheric Vent Water Heaters The next generation of Atmospheric Vent natural gas and propane water heaters handles a wide range of applications with inputs from 120,000 BTU to 500,000 BTU. With Intermittent Electronic Ignition, these units save energy by eliminating the standing pilot and the high pressure water jets reduce sediment at the bottom of the tank prolonging tank life. Features • Meets or exceeds ASHRAE 90.1 energy efficiency standard, 80% thermal efficiency • Self cleaning water jets - Reduces the build up of sediment at the bottom of the tank prolonging tank life • Inlet and outlet ports at the top, front and back • Factory-installed T&P and brass drain valve • Conveniently located hand hole cleanout • Low-profile vent damper for energy efficiency and installation in tight spaces • Intermittent Electronic Ignition - Eliminates standing pilot, saves energy, and provides flame failure response very quickly • Glass-lined tank with multiple anodes - Provides protection against corrosion extending tank life • Maximum hydrostatic working pressure 160 psi • ASME and high-altitude models available

Optional Accessories Available • Power Vent kits

3 year inner tank warranty, 1 year on parts.

11

www.johnwoodwaterheaters.com

John Wood® Commercial DIMENSIONS AND SHIPPING WEIGHT Input Rate

Approx. Tank Capacity

A

B

C

D

E

F

Gas Inlet G

H

I

J

BTU/h (kW)

USG (L)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

IN (CM)

120,000 (35) 154,000 (45) 199,000 (58) 199,000 (58) 199,000 (58) 251,000 (73) 275,000 (80) 305,000 (89) 365,000 (107) 390,000 (114) 500,000 (147)

71 (268) 81 (307) 95 (360) 76 (288) 100 (379) 65 (246) 100 (379) 65 (246) 65 (246) 100 (379) 85 (322)

69 3/4 (117) 73 (185) 75 (192) 67 1/2 (171) 72 (183) 75 (191) 72 (183) 75 (191) 79 1/2 (202) 75 1/2 (192) 82 1/4 (209)

4 1/4 (11) 4 1/4 (11) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12) 4 1/2 (12)

59 1/2 (151) 66 1/2 (169) 70 (178) 62 (157) 65 1/3 (165) 65 3/4 (167) 65 1/3 (165) 65 3/4 (167) 70 1/4 (178) 67 1/2 (171) 73 1/2 (187)

50 7/8 (129) 57 7/8 (147) 61 5/8 (157) 53 5/8 (136) 55 7/8 (142) 57 1/4 (145) 55 7/8 (142) 57 1/4 (145) 62 1/2 (159) 58 1/4 (148) 65 1/4 (166)

19 5/8 (50) 19 5/8 (50) 20 1/2 (52) 20 1/2 (52) 19 3/4 (50) 20 (51) 19 3/4 (50) 20 (51) 22 1/2 (57) 26 3/4 (68) 25 1/2 (65)

19 (48) 19 (48) 21 (53) 21 (53) 23 (58) N/A (N/A) 23 (58) N/A (N/A) 23 (58) 23 (58) 21 (53)

1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 3/4 (1.91) 3/4 (1.91) 1 (2.5)

51 7/8 (132) 59 (150) 62 5/8 (159) 54 5/8 (139) 56 3/8 (143) 58 3/4 (149) 56 3/8 (143) 58 3/4 (149) 63 (160) 59 (150) 65 3/4 (167)

6 (15) 6 (15) 6 (15) 6 (15) 6 (15) 8 (20) 8 (20) 8 (20) 8 (20) 8 (20) 8 (20)

27 3/4 (71) 27 3/4 (71) 27 3/4 (71) 27 3/4 (71) 30 1/4 (77) 27 3/4 (71) 30 1/4 (77) 27 3/4 (71) 27 3/4 (71) 30 1/4 (77) 27 3/4 (71)

Model

JWSM-71-120 JWSM-81-154 JWSM-95-199 JWSM-76-199 AJWSM-100-199 (A)JWSM-65-251 AJWSM-100-275 (A)JWSM-65-305 (A)JWSM-65-365 AJWSM-100-390 AJWSM-85-500

Connections Inlet

Approx. Shipping Weight

Outlet

Top

Front

Back

Top

Front

Back

STD.

ASME

IN (CM) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) N/A (N/A) 1 1/2 (3.81) N/A (N/A) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81)

IN (CM) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81)

IN (CM) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 2.00 (5.08) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81)

IN (CM) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) N/A (N/A) 1 1/2 (3.81) N/A (N/A) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81)

IN (CM) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81)

IN (CM) 1/2 (1.27) 1/2 (1.27) 1/2 (1.27) 2 (5.08) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81) 1 1/2 (3.81) 1 1/2 (3.81) 2 (5.08) 1 1/2 (3.81)

LBS (KG) 400 (182) 470 (213) 603 (273) 470 (213) N/A (N/A) 750 (341) N/A (N/A) 750 (341) 725 (329) N/A (N/A) N/A (N/A)

LBS (KG) N/A (N/A) N/A (N/A) N/A (N/A) N/A (N/A) 725 (329) 862 (391) 725 (329) 862 (391) 833 (379) 874 (396) 857 (389)

Note: For NG add N to end. For LP add P. For high altitude models (2,000-4,500ft) add H. Example: JWSM-71-120NH.

PERFORMANCE AND RECOVERY RATE (GPH/LPH)

Model

EFF. %

JWSM-71-120

80

JWSM-81-154

80

JWSM-95-199

80

JWSM-76-199

80

AJWSM-100-199

80

(A)JWSM-65-251

80

AJWSM-10-275

80

(A)JWSM-65-305

80

(A)JWSM-65-365

80

AJWSM-100-390

80

AJWSM-85-500

80

Recovery Rate Capacities GPH (LPH) 30°F (17°C)

40°F (22°C)

50°F (28°C)

60°F (33°C)

70°F (39°C)

80°F (45°C)

90°F (50°C)

100°F (56°C)

110°F (61°C)

120°F (67°C)

130°F (72°C)

140°F (78°C)

388 (1469) 498 (1885) 643 (2434) 614 (2324) 643 (2434) 811 (3071) 899 (3365) 986 (3732) 1164 (4405) 1293 (4894) 1616 (6118)

291 (1102) 373 (1412) 482 (1825) 461 (1745) 482 (1825) 608 (2303) 667 (2524) 739 (2799) 873 (3304) 970 (3671) 1212 (4588)

233 (882) 299 (1132) 386 (1461) 368 (1393) 386 (1461) 487 (1843) 533 (2019) 592 (2239) 698 (2643) 776 (2936) 970 (3671)

194 (734) 294 (943) 322 (1219) 307 (1162) 322 (1219) 406 (1536) 444 (1682) 493 (1866) 582 (2202) 646 (2447) 808 (3059)

166 (628) 213 (806) 276 (1045) 263 (996) 276 (1045) 348 (1316) 381 (1442) 423 (1599) 499 (1888) 554 (2097) 693 (2622)

145 (549) 187 (708) 241 (921) 230 (871) 241 (912) 304 (1152) 333 (1262) 370 (1399) 436 (1652) 485 (1835) 606 (2294)

129 (488) 166 (628) 214 (810) 205 (776) 214 (731) 270 (1024) 296 (1122) 329 (1244) 388 (1468) 431 (1631) 539 (2039)

116 (439) 149 (564) 193 (731) 184 (697) 193 (731) 243 (921) 267 (1009) 296 (1120) 349 (1321) 388 (1468) 485 (1835)

106 (401) 136 (515) 175 (662) 167 (632) 175 (662) 221 (838) 242 (918) 269 (1018) 317 (1201) 353 (1335) 441 (1668)

97 (367) 124 (469) 161 (609) 154 (583) 161 (609) 203 (768) 222 (841) 246 (933) 291 (1101) 323 (1224) 404 (1529)

90 (41) 115 (435) 148 (560) 142 (538) 148 (560) 187 (709) 205 (776) 228 (861) 269 (1016) 298 (1129) 373 (1412)

83 (314) 107 (405) 132 (500) 132 (500) 132 (500) 174 (658) 190 (721) 211 (800) 249 (944) 277 (1049) 346 (1331)

J

12

Storage Tanks Our line of professional hot water recirculating storage tanks are available in 80 and 119 US gallon models, jacketed and insulated or bare and enamel painted. Manufactured with ease of installation in mind, connections are simplified for large recirculating water lines, while the tanks come complete with easily accessible openings for a one inch T&P valve and a 3/4 inch aquastat. 2” NPT (2½” FOR JWCE-119) 3/4” NPT (ANODE)

Features • Glass-lined tank to protect against corrosion • Threaded openings - for thermometer, relief valve, recirculation lines, aquastat and drain valve • Magnesium anode(s) • 150 psi working pressure • Insulated models use high density fiberglass insulation to reduce costly heat loss; non-sagging and vermin-proof

(PLEASE NOTE THAT ACTUAL LOCATIONS OF OPENINGS MAY VARY DEPENDING ON MODEL)

DIMENSIONS AND SHIPPING WEIGHT Capacity

Shipping Weight

Dimensions

Model

JACKETED JWCST-80 JWCST-119 BARE TANK JWCE-80 JWCE-119

USG/L

A IN / CM

B IN / CM

C IN / CM

D IN / CM

E IN / CM

F IN / CM

G IN / CM

H IN / CM

I IN / CM

J IN / CM

K IN / CM

LBS/ KG

80 / 303 119 / 450

54 7/8 / 139 62 / 157

26 1/2 / 67 29 3/8 / 75

42 3/4 / 109 54 1/4 / 138

32 1/4 / 82 42 1/4 / 107

19 1/2/ 50 15 / 38

11/ 28 11 / 28

9 3/4/ 25 4 1/8 / 10

¾/2 ¾/2

2/ 5 2/ 5

¾/2 2/ 5

2/ 5 1/3

236 / 137 320 / 145

80 / 303 119 / 450

61 1/2 / 156 64 3/8 / 164

20 / 51 24 1/4 / 62

58 / 147 53 7/8 / 137

46 1/4 / 117 34 1/2 / 88

16 / 41 15 1/2 / 39

7 / 18 7 / 18

3 1/4 / 8 3 1/2 / 9

¾/2 ¾/2

2/ 5 2½/6

2/ 5 2½/6

2/ 5 2½/6

170 / 77 287 / 130

5 year inner tank warranty, 1 year on parts.

13

www.johnwoodwaterheaters.com

John Wood® Commercial Oil-Fired Water Heaters Complete with TankSaver® technology, an exclusive innovation that impedes corrosion, John Wood oil-fired water heaters feature a universal mounting design that fits most burners. Its ceramic fibre combustion chamber maximizes heat retention, while its immersion-type aquastat allows for precise water temperature control. Features • High output, high efficiency multi flue design for FAST recovery

• Equipped with multiple anode rods for long life

• Factory installed T&P and drain valve • Universal mounting design suits most burners

• Meets CSA B140.0-03 • TankSaver® Options Approved for installation with the following burner:

• Beckett AFG 1.0 - 1.25 GPH (Product Number J7006)

DIMENSIONS

Model

JWF657

PERFORMANCE

Height to Flue

Height to Top of Tank

Diameter

Flue Diameter

A IN / CM

B IN / CM

C IN / CM

D IN / CM

IN / MM

LBS / KG

68 3/4 / 175

65 3/8 / 166

26 / 66

6 / 15

1 / 25

379 / 172

Water Connections

Shipping Weight

Capacity Model

JWF657

Firing Rate

USG/L

USG/h

65 / 238

1 - 1.25

Input in BTU/h

138,500

Blast Tube Insertion Length

Recovery 100°F Rise

55°C Rise

GPH

LPH

129

488

Combustion Efficiency

IN / CM 7 3/4 / 20

82-86%

Certified for use with CSA approved field power venter, Field Controls Model SWG11 4HD. 3 year inner tank warranty, 1 year on parts.

14

Light Duty Atmospheric Gas Water Heaters John Wood® light duty gas water heaters are designed for commercial applications where there is a lower demand for hot water up to 180°F. They are ideal for small beauty salons, barber shops, dairy barns, coin laundries and food service counters, supplying enough hot water to economically meet the requirements of these applications. Features • Glasslined tank • Fully automatic controls with safety shutoff • Heavy gauge steel jacket • Foam insulation helps reduce standby heat loss • Certified for installation on combustible flooring • All connections are located in front and top of heaters for ease of installation and service • Low profile draft hood • Maximum working pressure 150 psi • Handhole cleanout allows easy tank cleaning • Built-in gas filter and integral dirt leg (propane only) • Equipped with gas pressure regulator

PERFORMANCE AND DIMENSIONS Shipping Weight

Capacity

Input

Dimensions

USG/L

BTU/h

A IN / CM

B IN / CM

C IN / CM

D IN / CM

E IN / CM

F IN / CM

G IN / CM

H IN / CM

J IN / CM

K IN

L IN

M IN / CM

LBS / KG

75 / 284

75,100

61 1/8 / 155

58 1/2 / 147

26 1/2 / 66

15 13/16 /39

16 / 41

4 / 10

14 1/2 / 36

29 11/16 / 74

54 1/4 / 137

1 NPT

1/2 NPT

11 15/16 / 28

350 / 159

75 / 284

75,100

61 1/8 / 155

58 1/2 / 147

26 1/2 / 66

15 13/16 /39

16 / 41

4 / 10

14 1/2 / 36

29 11/16 / 74

54 1/4 / 137

1 NPT

1/2 NPT

11 15/16 / 28

350 / 159

Model

NATURAL GAS JW375T75N-AV PROPANE JW375T75P-AV

3 year inner tank warranty, 1 year on parts.

15

www.johnwoodwaterheaters.com

Exclusive Designs, Built-to-Last John Wood® Water Heaters are designed and built with exclusive features to ensure maximum quality, safety and reliability. Our heaters are thoroughly factory tested for cold climates and harsh water conditions, are field-proven and meet or exceed industry standards.

TankSaver® The exclusive TankSaver® design prolongs tank life. TankSaver® impedes corrosion by guarding metal tank openings from exposure and keeping them watertight. The durable construction virtually eliminates rust.

ASHRAE Efficiency Standard 90.1 John Wood commercial water heaters meet the ASHRAE Efficiency Standard 90.1. The burner efficiency of these units is over 80%.

American Society of Mechanical Engineers (ASME) Our manufacturing facilities have been authorized by ASME to build tanks in accordance with the ASME Boiler and Pressure Vessel Code.

Certified Hydrostatic Tests Design test pressure – 300 psi. Maximum working pressure – 150 psi.

Coast-to-Coast Service & Support In order to bring you unsurpassed quality and reliability after you’ve purchased a John Wood product, we’ve created a number of service and support resources to help take you through installation and beyond. Our Technical Support call center is staffed by technical experts who provide in-depth product support and troubleshooting advice. As well, our spare parts inventory carries a comprehensive supply of parts to help make repairs fast and easy. Also, our user-friendly website is available 24 hours a day/7 days a week and offers access to many valuable resources such as warranty validations and claims, comprehensive parts catalogue, literature and manuals.

16

Sample Specifications Tankless Models Water heater(s) shall be John Wood powered by Takagi Model____________________ as manufactured by Takagi, shall be a copper coil integral fin and tube construction with quick release brass or bronze waterways. Heater(s) will be factory assembled and tested. Commercial Condensing water heaters shall be vented with 3” or 4” Schedule 40 ULC S636 PVC, CPVC, or polypropylene vent pipe, or stainless steel Category III/IV vent pipe at a distance not to exceed 70’ (equivalent) for 3” vent or 100’ (equivalent) for 4” vent, terminating vertically or horizontally as prescribed. Intake air pipe may be of such material as ABS, PVC, polypropylene, galvanized B-Vent, corrugated aluminum or stainless steel, or Category III/IV stainless steel not to exceed 70’ (equivalent) for 3” vent or 100’ (equivalent) for 4” vent. Commercial Non-Condensing water heaters shall be vented with 4” or 5” Category III stainless steel vent pipe a distance not to exceed 50’ (equivalent) feet terminating vertically or horizontally as prescribed. Intake air with optional direct vent kit may be of such material as PVC or CPVC, galvanized B-Vent, corrugated aluminum or stainless steel or Category IV stainless steel not to exceed a total of 50’ (equivalent). The heater(s) shall be controlled by an onboard solid-state printed circuit board monitoring incoming and outgoing temperatures with factory installed thermistors, sensing and controlling flow rate to set point temperature, controlling both air and gas mixture inputs to maintain thermal combustion efficiency. The heater(s) shall also consist of inline fusing, a spark ignition and sensor system, aluminized stainless steel burners, an air-fuel ratio sensor, a hi-limit temperature switch, modulating and proportional gas valves, a freeze protection sensor with ceramic heating blocks, and an overheat cutoff fuse. The water heater(s) shall be CSA listed and exceed the energy efficiency requirements of ASHRAE 90.1b.

Commercial Electric Models Heavy-Duty Surface Thermostat Models Commercial electric water heater(s) shall be John Wood Model _____________________ as manufactured by A. O. Smith and listed with Underwriters Laboratories (UL) for commercial water heater(s) having delivery capabilities of 180°F water, and meet or exceed all applicable energy codes. Water heater(s) shall have a storage capacity of ________ US gallons, a surface-mounted thermostat, and gold-plated screw-in elements having a total combined electrical rating of ___________ kW _____________ V ____________Phase 50/60 cycle AC. Heater shall be design tested and listed in accordance with CSA International standards. Heaters shall comply with ASHRAE Standard 90.1. Recovery capacity rating of __________ GPH at ___________°F temperature rise. Water heater(s) steel tank is design certified to 300 PSI having a working pressure of 150 PSI and shall have a glass lining applied under pressure and fired at 1600°F allowing for maximum protection. Water heater(s) shall be equipped with a full-size boiler-type inspection port/cleanout to help reduce scale and corrosive deposits within the water heater, and an approved pressure and temperature relief valve factory installed. Water heater(s) shall be equipped with surface-mounted high-limit and fused-component protection within a hinged-door control box allowing easy access to pre-wired equipment. Full-size element compartment allows total access to service and maintain equipment. Multiple knockouts permit size selection from 3/4” to 2” meeting electrical code requirements. Water heater(s) shall be provided with a manual reset high-limit device and anodes for cathodic protection. The outer jacketing shall have a smooth baked enamel finish. The tank shall be foam insulated with a non-CFC material. Water heater(s) shall have a 3-year limited tank warranty as outlined in the written warranty. Fully illustrated operation, installation and service manual included with the unit.

Commercial Electric Heavy-Duty Immersion Thermostat Models Commercial electric water heater(s) shall be John Wood Model ________________ as manufactured by A. O. Smith and listed with Underwriters Laboratories (UL) for commercial water heater(s) having delivery capabilities of 180°F water and meet or exceed all applicable energy codes. Water heater(s) shall have a storage capacity of _____ US gallons, an immersion thermostat, and gold-plated screw-in elements having a total combined electrical rating of ___________ kW ___________

17

www.johnwoodwaterheaters.com

V ___________ Phase, 50/60 cycle AC. Recovery capacity rating of ___________GPH at ___________°F temperature rise. Heaters shall be design tested and listed in accordance with CSA International standard. Heaters shall comply with ASHRAE Standard 90.1. Water heater(s) steel tank is hydrostatic tested at 300 PSI having a working pressure of 150 PSI and shall have a glass lined tank applied under pressure and fired at 1600°F allowing for maximum protection. Water heater(s) shall be equipped with a full-size boilertype inspection port/cleanout to help reduce scale and corrosive deposits within the water heater, and an approved pressure and temperature relief valve factory installed. Water heater(s) shall be equipped with an electronic display, as well as surface-mounted high-limit and fused-component protection within a hinged-door control box allowing easy access to prewired equipment. Full-size element compartment allows total access to service and maintain equipment. Multiple knockouts permit size selection from 3/4” to 2” meeting electrical code requirements. Water heater(s) shall be provided with a manual reset high-limit device and anodes for cathodic protection. The outer jacketing shall have a smooth baked enamel finish. The tank shall be foam insulated with non-CFC material. Water heater(s) shall have a 3-year limited tank warranty as outlined in the written warranty. Fully illustrated operation, installation and service manual included with the unit.

Polaris® Commercial Gas Models Commercial gas-fired water heater(s) shall be a direct/power vent Polaris® Model __________ as manufactured by American Water Heater Company and shall have a 3-year limited tank warranty and a 1-year limited parts warranty, as outlined in the written warranty. Units shall be designed to burn ________ (natural/propane) gas and be CSA International certified to the latest edition of ANSI Standard Z21.10.3/CSA 4.3. Water heater(s) shall have a nominal storage capacity of _____ US gallons and a recovery rate of _____ GPH at 100°F rise with a rated input of _______ BTU/h. Water heater(s) shall be condensing type with a minimum thermal efficiency of 95-96%, power vented with ULC S636 approved PVC or CPVC pipe. Water heater(s) shall have combined vent capabilities of up to 120’ to the exhaust outlet with up to 120’ to the air inlet. Water heater(s) shall have a low noise combustion system with a woven fibre steel burner capable of low NOx (less than 40 ng/J) in the blue flame mode and shall be manufactured of refractory steel, resistant to thermal and mechanical shock. The gas valve shall be a Honeywell CV1-r1 series gas valve with a matching 45.900 series venturi manifold using a 1:1 air/gas ratio. The combustion system shall be factory

adjusted and require no field adjustment on startup. The tank shall be constructed of 444 stainless steel with a submerged combustion chamber and rated for 150 PSI working pressure and 300 PSI test pressure. The tank shall be surrounded by two inches of non-CFC foam insulation covered by an enamel coated metal jacket. Operating controls shall have a 24-volt integrated control circuit, an immersed thermistor temperature sensor, a recycling energy cut-off switch, external temperature adjustment up to 185°F, and shall have LED lights that continuously indicate the operational status of the water heater(s). A microprocessor shall automatically monitor nine critical operating functions and signal the status of each. A factoryinstalled temperature and pressure relief valve shall be provided.

Commercial Storage Tank (Jacketed) Commercial storage tank(s) shall be John Wood Model ________________ as manufactured by A. O. Smith. Storage tank(s) are hydrostatic tested at 300 PSI having a working pressure of 150 PSI and shall have a glass lined tank applied under pressure and fired at 1600°F allowing for maximum protection. Storage tank(s) shall be equipped with a full-sized boiler-type inspection port/cleanout. The outer jacketing shall have a smooth baked enamel finish. The tank shall be foam insulated with a non-CFC material 2” in thickness. Storage tank(s) shall have a 5-year limited warranty as outlined in the written warranty.

Commercial Storage Tank (Bare) Commercial storage tank(s) shall be John Wood Model________________ as manufactured by A. O. Smith. Storage tank(s) are hydrostatic tested at 300 PSI having a working pressure of 150 PSI and shall have a glass lined tank applied under pressure and fired at 1600°F allowing for maximum protection. Storage tank(s) shall be equipped with a full-sized boiler-type inspection port/cleanout. Storage tank(s) shall have a 5-year limited warranty as outlined in the written warranty.

Commercial Oil Model Commercial oil water heater(s) shall be John Wood Model JWF657 as manufactured by A. O. Smith design and listed with CSA International for commercial water heater(s) having delivery capabilities of 180°F water and meet or exceed all applicable energy codes. Water heater(s) shall have a storage capacity of 65 US gallons, 138,500 BTU/h input. Recovery capacity rating of 142 GPH at 100° F temperature rise. Heaters shall be design tested and listed in accordance with CSA International standard. Heaters shall comply with ASHRAE Standard 90.1. Water heater(s) steel tank is hydrostatic tested at 300 PSI having a working pressure of 150 PSI and shall have a glass lined tank applied under pressure and fired at 1600°F allowing for maximum protection. Water heater(s) shall be equipped with a full-size boiler-type inspection port/cleanout to help reduce scale and corrosive deposits within the water heater, and an approved pressure and temperature relief valve factory installed. Water heater(s) shall be equipped with an immersion type aquastat and ECO. Water heater(s) shall be provided with a manual reset high limit device and anodes for cathodic protection. The outer jacketing shall have a baked enamel finish. The tank shall be insulated with a non-CFC material. Water heater(s) shall have a 3-year limited tank warranty as outlined in the written warranty. Fully illustrated operation, installation and service manual included with the unit.

Commercial Atmospheric Vent Gas Models Atmospheric Vent Commercial gas-fired water heater(s) shall be John Wood Model __________ as manufactured by A. O. Smith, and shall

have a 3-year limited tank warranty and a 1-year limited parts warranty, as outlined in the written warranty. Units shall be designed to burn ________ (natural/propane) gas and be design certified by Underwriters Laboratories (UL) under Volume III tests for commercial water heaters for delivery of 180°F water and to the current edition of ANSI Standard Z21.10.3/CSA 4.3. Water heater(s) shall have a nominal storage capacity of _____ US gallons and a recovery rate of _____ GPH at 100°F rise with a rated input of _______ BTU/h and a maximum hydrostatic working pressure of 160 PSI. Water heater(s) shall be protected against overheating caused by the build-up of scale, film and other sediment by a self-cleaning device, positioned inside the tank so that it directs the flow of inlet water to keep precipitated solids in suspension so that they are removed from the water heater on that or successive draws. Glass-lined water heater(s) shall also be protected against electrolytic corrosion by multiple factory-installed anode rods. Water heater(s) shall be equipped with an integrated control system consisting of a 180°F adjustable thermostat with upper and lower sensing bulbs, intermittent electronic ignition, a manual reset gas shut-off device, a gas pressure regulator, automatic flue damper, and a full-size boiler-type inspection port/cleanout. A factory-installed temperature and pressure relief valve shall be provided on all models.

Additional Specifications for ASME-Coded Atmospheric Vent Commercial Gas Model(s) Atmospheric Vent Commercial gas water heater(s) shall be John Wood Model _________________ as manufactured by A. O. Smith shall be constructed to Section IV of the ASME Code for 150 PSI working pressure and a stamped National Board labeling permanently affixed to the tank and accessible for inspection.

High-Efficiency Commercial Modulating Gas Models High-Efficiency Commercial modulating gas-fired water heater(s) shall be John Wood High-Efficiency Model __________ as manufactured by A. O. Smith, and shall have a 3-year limited tank warranty and a 1-year limited parts warranty, as outlined in the written warranty. Units shall be designed to burn ________ (natural/propane) gas and meet ASHRAE/IES 90.1 requirements for thermal efficiency and standby loss. Water heater(s) shall have a nominal storage capacity of _____ US gallons and a recovery rate of _____ GPH at 100°F rise with a rated input of _______ BTU/h and a maximum hydrostatic working pressure of 160 PSI. Water heater(s) shall have a minimum thermal efficiency of 95%, power vented with ULC S636 approved PVC, CPVC, polypropylene or AL29-4C stainless steel vent pipe. Water heater(s) shall have a power burner, seamless glass-lined tank construction, condensing flue coil that is coated on the flue gas side with acid-resistant glass lining designed for use in condensing heaters, and maintenance-free powered anode. The control system includes an integrated solid-state temperature and ignition control device with integral diagnostics, LCD fault display capability, and a digital display of temperature settings. The combustion system shall be factory adjusted and require no field adjustment on startup. A factory-installed ASME-rated temperature and pressure relief valve shall be provided on all models.

Additional Specifications for ASME-Coded High-Efficiency Commercial Gas Model(s) High-Efficiency Commercial gas water heater(s) shall be John Wood Model _________________ as manufactured by A. O. Smith shall be constructed to Section IV of the ASME Code for 150 PSI working pressure and a stamped National Board labeling permanently affixed to the tank and accessible for inspection.

18

Head Office: 599 Hill Street West Fergus, ON N1M 2X1 Tel: 519-843-1610 Fax: 519-787-5500 Technical Support and Warranty: Tel: 1-888-479-8324 Sales/Customer Service: Tel: 1-888-599-2837

[email protected] www.johnwoodwaterheaters.com

0914 Printed in Canada C301C