www.lg.com/za

COMMERCIAL AIR CONDITIONERS LG Electronics AE Company, Commercial Air Conditioning Raceway Industrial Park, Monte Carlo Drive, Gosforth Park, Germiston www.lg.com/za m.lg.com/za Copyright © 2015 LG Electronics. All rights reserved.

Distributed by

2015

HIGH RELIABILITY SINGLE SPLIT

SINGLE SPLIT STANDARD INVERTER

Outlet Temp.

Quick

OutletTemp. Temp. Outlet 40ºC 40ºC 40ºC

44% 44% %

PRESSURE SENSOR

Pressure + Temperature Control Temperature Control

TEMPERATURE SENSORS

Wide

3

5

33

55

Time

Time Time

Indoor Temp. IndoorTemp. Temp. Indoor

Heating

Low Ambient Control

Cooling Outdoor Temp. OutdoorTemp. Temp. Outdoor

CONVENTIONAL TEMPERATURE CONTROL

TEMPERATURE + PRESSURE CONTROL

Stable

Outdoor Load OutdoorLoad Load Outdoor

Capacity Capacity Capacity

Cooling

Temperature Sensor

Pressure Sensor

Cooling Cooling

Outdoor Temp.

OutdoorTemp. Temp. Outdoor Load Outdoor OutdoorLoad Load Outdoor

Calculates target pressure according to indoor/outdoor temperature, desired temperature and piping length.

Senses and controls pressure directly using pressure sensor for faster and more exact response to load variation

Heating Heating Heating

3

Outdoor Temp. OutdoorTemp. Temp. Outdoor

Improvement of comfort levels due to accurate response to the operation load Outdoor Temp. OutdoorTemp. Temp. Outdoor

4

SINGLE SPLIT

1

SUPREME ENERGY EFFICIENCY

2

High efficiency

SEER

SCOP

6.11 4.11 1 Highly Efficient Heat Exchanger 2 BLDC Fan Motor Technology

The revolutionary inverter technology of LG boasts powerful yet silent performance while minimizing energy consumption.

* Based on UT12H NP1 / UU12WH UE1

HEAT EXCHANGER WITH WIDE LOUVER FIN

Heat exchange rate(%)

POWERFUL BLDC COMPRESSOR

128% Improved heat exchanger efficiency of up to123% 28%, using MULTI V technology.

LG air conditioners are equipped with a BLDC compressor that uses a strong neodymium magnet. 128 The compressor has improved efficiency compared to standard AC inverter products and it is optimised 123for seasonal efficiency. EER

100

100

Cooling

100

New Concentrated Winding

4%

C

H

C

H

60Hz

80Hz

100%

Heating

100%

New Wide Louver Fin

Conventional Corrugate Fin Heat Exchange Rate(%)

20 ~ 100 Hz

Corrugate fin

Frequency

123%

Cooling

Conventional Distributed Winding

40Hz

20 ~ 100 Hz

128%

Heating

Operation Frequency

8%

3

3 Powerful BLDC Compressor

* Applied to Standard Inverter except UU09W ULD / UU12W ULD

Wide louver fin

OPTIMISED HEAT EXCHANGER PATH Improved cycle efficiency up to 5% with equal distribution.

BLDC FAN MOTOR TECHNOLOGY The LG BLDC fan motor offers additional energy savings of up to 40% at low speeds and 20% at high speeds compared to an AC motor.

Conventional

New

Unequal Distribution

Equal Distribution

Efficiency(%) 100 80 60

20 % increase

40%

40

DC Motor

increase

AC Motor

20 0

BLDC Fan Motor 5

200

400

600

800

1,000

Motor Speed(RPM) 6

SINGLE SPLIT

HIGH OPERATION RELIABILITY

Pressure Sensor

Temperature Sensors

Quick Operation Response up to 44% faster Wide Operation Range -15~48°C Stable Operation Performance

HIGH RELIABILITY WITH PRESSURE CONTROL

IDEAL SOLUTION FOR SERVER ROOMS

LG air conditioners are equipped with a BLDC compressor that uses a strong neodymium magnet. The compressor has improved efficiency compared to standard AC inverter products and it is optimised for seasonal efficiency.

• Wide Operation Range : Cooling -15~48°C

Cooling

30

Temperature Sensor

48°C

Indoor Temp.(°C)

Heating

Pressure Sensor

Ideal solution for server rooms, machine rooms and kitchens.

23

Conventional Temperature Control Calculates target pressure according to indoor/outdoor temperature, desired temperature and piping length.

-5 °C More

Temperature + Pressure Control Senses and controls pressure directly using pressure sensor for faster and more exact response to load variation

16

Low Ambient Control

Cooling

12

QUICK OPERATING RESPONSE

Outdoor Temp.(°C) -18

(WB)

Pressure control takes up to 44% less time to reach the desired temperature with a high level of accuracy and stability.

-15

-10

0

(DB)

18

48

(WB)

(DB)

• High and Stable Performance at Low Temperatures

Outlet Temp. (°C)

Room Temp.(°C)

44%

44%

30

3min 7min Off On

Room Temp.(°C)

Outdoor -10°C

21

3 5

21

The indoor environment can be made more comfortable, faster and more accurately.

Pressure + Temperature Control Temperature Control Time

*Based on internal test data

Outdoor -15°C

30

Quicker

40

7

* UU09W ULD / UU12W ULD Cooling Range : -10~43°C

Continuous Operation

Time

Conventional

Time

New 8

CEILING CASSETTES

CEILING CASSETTES WIDE JET AIR FLOW Improved vanes reduce the curved area and provide better air and temperature distribution.

Conventional

m e 80Wm d i rr

t 26 27°C 25

mm 567

Air flow dead zone in 4 corners

m mm 48877m

24 23 22 21 20 19 15°C 18

LG Cassette t 26 27°C 25

Even air distribution

24 23 22 21 20 19 15°C 18

INDEPENDENT VANE OPERATION It is possible to control each of the 4 vanes individually as the motors are connected separately to each vane.

1step

20°

30°

40°

50°

60°

6step

70°

Direct air flow All vane operation

Indirect air flow

Individual vane angle control

* Wired remote controller PQRCVSL0(QW) applied

9

10

CEILING CASSETTES

STANDARD INVERTER

CEILING CASSETTES REDUCED SOUND LEVEL BLDC motor delivers low indoor noise levels by using the high efficiency turbo fan. Anti vibration design reduces resonance noise.

Hanger adjust

CONVENIENT PANEL INSTALLATION

Wind-amount mode Low-Low

Low

Medium

High

The detachable corner design makes it easy to adjust the hanger during installation and to check for leakages in the drain connection pipe.

Power

Detachable Corner Design

AC Motor

BLDC Motor 70%

90%

100%

110%

Attachable/detachable Attachable/detachable corner cornerdesign design

Refrigerant piping check and Hanger adjust Refrigant Refrigant

check check

Piping Pipingcheck check

130%

Drain leakage check Drain Drainleakage leakage and Hanger adjust

Airflow variable range Hanger Hangeradjust adjust

Hanger Hangeradjust adjust

Hanger adjust

HIGH CEILING MODE

Detachable Detachable Corner CornerDesign Design

High ceiling mode provides powerful cooling and heating up to 4.2m in height, from ceiling to floor. Refrigant Refrigant Piping Pipingcheck check

4.2m

Hanger Hangeradjust adjust

Dr

Hanger adjust

Drain leakage check

Hanger adjust

Drain DrainLeakage LeakageCheck Check

Hanger HangerAdjust Adjust

Drain Drainleakage leakage check check

Hanger Hangeradjust adjust

It is easy to install the panel to the body, using the button type panel design.

11

12

STANDARD INVERTER

STANDARD INVERTER

STANDARD INVERTER

STANDARD INVERTER

CT12 / CT18 / CT24 / UT30

UT36 / UT48 / UT60

UU12W

UU24W UU30W

UU18W

(Included PQRCVSLOQW)

UU49W UU61W

UU37W

(Included PQRCVSLOQW)

* CT12 / CT18 / CT24 are compatible with SCAC and MULTI.

Indoor Capacity Low Temperature Capacity Power Input (Set) Power Input (Indoor) Running Current Power Supply EER COP SEER SCOP Pdesign (@-10°C) Seasonal Energy Label Annual Energy Consumption Piping Connection Air Flow Rate Sound Pressure Sound Power Dehumidification Rate Dimensions Net Weight Decoration Panel

Cooling Heating Heating -7°C Cooling Heating Cooling/Heating

Min/Nom/Max Min/Nom/Max Max Nom Nom Min/Nom/Max Nom

kW kW kW kW kW W A ø/V/Hz

kW Cooling/Heating Cooling/Heating Liquid Gas Drain Cooling Cooling Body Body Model Color Dimensions Weight

O.D./I.D. High/Medium/Low High/Medium/Low Max WxHxD

WxHxD

kWh mm(inch) mm(inch) mm m3/min dBA dBA l/h mm kg

mm kg

Outdoor Compressor Airflow Rate Sound Pressure Sound Power Dimensions Net Weight Refrigerant Operation Range (Outdoor) Power Supply Power Supply Cable Transmission Cable Circuit Breaker Piping Length Total Piping Elevation Difference Piping Connection

13

Type Cooling Heating Cooling WxHxD

Nom Nom Nom Max

Type Charge Additional Charge (after 7.5m) Cooling Min~Max Heating Min~Max

IDU-ODU Liquid Gas

Min~Max Max

m3/min dBA dBA dBA mm kg g g/m °C DB °C WB ø/V/Hz No.xmm² No.xmm² A m m mm(inch) mm(inch)

CT12 NR2

CT18 NQ2

CT24 NP2

UT30 NP2

1.4 / 3.4 / 3.7 1.6 / 4.0 / 4.4 3.6 1.06 1.10 10 / 20 / 20 4.61 / 4.78 1 / 220-240 / 50 3.21 3.64 5.61 3.91 3.0 A+ / A 213 / 1,077 ø 6.35 (1/4) ø 9.52 (3/8) 32 / 25 9.5 / 8.0 / 7.0 38 / 35 / 32 51 1.7 570 x 214 x 570 14.0 PT-UQC Morning Fog 700 x 22 x 700 3.0

2.0 / 4.7 / 5.5 2.2 / 5.5 / 6.1 4.9 1.46 1.52 10 / 30 / 40 6.3 / 6.6 1 / 220-240 / 50 3.22 3.62 4.81 3.81 4.0 B/A 343 / 1,474 ø 6.35 (1/4) ø 12.7 (1/2) 32 / 25 13.0 / 12.0 / 11.0 41 / 39 / 36 55 2.1 570 x 256 x 570 15.5 PT-UQC Morning Fog 700 x 22 x 700 3.0

2.8 / 7.1 / 7.8 3.2 / 8.0 / 8.8 7.2 1.92 2.21 20 / 50 / 60 8.3 / 9.6 1 / 220-240 / 50 3.70 3.62 6.11 3.81 6.5 A++ / A 407 / 2,395 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 17.0 / 15.0 / 13.0 38 / 36 / 34 57 2.4 840 x 204 x 840 20.5 PT-UMC1 Morning Fog 950 x 25 x 950 5.0

3.2 / 8.0 / 8.8 3.6 / 9.0 / 9.9 8.1 2.49 2.72 30 / 70 / 80 10.8 / 11.8 1 / 220-240 / 50 3.21 3.31 6.11 3.81 6.8 A++ / A 459 / 2,505 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 19.0 / 17.0 / 15.0 40 / 37 / 35 57 2.5 840 x 204 x 840 20.5 PT-UMC1 Morning Fog 950 x 25 x 950 5.0

UU12W ULD

UU18W UE2

UU24W U42

UU30W U42

Outdoor

Rotary 32 47 48 57 770 x 540 x 245 32.0 R410A 1,000 20 -10 ~ 43 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 15 5 ~ 15 10 ø 6.35 (1/4) ø 9.52 (3/8)

Twin Rotary 50 48 51 60 870 x 655 x 320 46.0 R410A 1,400 20 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 20 5~40 30 ø 6.35 (1/4) ø 12.7 (1/2)

Twin Rotary 58 48 52 62 950 x 834 x 330 60.0 R410A 2,000 40 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 30 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 58 48 52 65 950 x 834 x 330 60.0 R410A 2,000 40 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 30 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Compressor Airflow Rate

Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB /19°C WB - Outdoor Temperature 35°C DB /24°C WB 3. Annual energy consumption: based on average use of 500 running hours per year at nominal condition Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB

Indoor Capacity Low Temperature Capacity Power Input (Set) Power Input (Indoor) Running Current Power Supply EER COP SEER SCOP Pdesign (@-10°C) Seasonal Energy Label Annual Energy Consumption Piping Connection Air Flow Rate Sound Pressure Sound Power Dehumidification Rate Dimensions Net Weight Decoration Panel

Sound Pressure Sound Power Dimensions Net Weight Refrigerant Operation Range (Outdoor) Power Supply Power Supply Cable Transmission Cable Circuit Breaker Piping Length Total Piping Elevation Difference Piping Connection

Cooling Heating Heating -7°C Cooling Heating Cooling/Heating

Min/Nom/Max Min/Nom/Max Max Nom Nom Min/Nom/Max Nom

kW kW kW kW kW W A ø/V/Hz

kW Cooling/Heating Cooling/Heating Liquid Gas Drain Cooling Cooling Body Body Model Color Dimensions Weight

O.D./I.D. High/Medium/Low High/Medium/Low Max WxHxD

WxHxD

kWh mm(inch) mm(inch) mm m3/min dBA dBA l/h mm kg

mm kg

Type Cooling Heating Cooling WxHxD

Nom Nom Nom Max

Type Charge Additional Charge (after 7.5m) Cooling Min~Max Heating Min~Max

IDU-ODU Liquid Gas

Min~Max Max

m3/min dBA dBA dBA mm kg g g/m °C DB °C WB ø/V/Hz No.xmm² No.xmm² A m m mm(inch) mm(inch)

Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB /19°C WB - Outdoor Temperature 35°C DB /24°C WB. 3. Annual energy consumption: based on average use of 500 running hours per year at nominal condition Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB

UT36 NN2

UT48 NM2

UT60 NM2

4.0 / 10.0 / 11.0 4.4 / 11.0 / 12.1 9.8 2.82 3.09 40 / 130 / 140 4.1 / 4.5 1 / 220-240 / 50 3.55 3.56 5.41 3.81 7.6 A/A 648 / 2,800 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 24.0 / 22.0 / 19.0 43 / 40 / 37 62 2.7 840 x 246 x 840 22.3 PT-UMC1 Morning Fog 950 x 25 x 950 5.0

5.5 / 13.9 / 15.7 6.4 / 15.3 / 17.6 14.3 4.62 4.49 80 / 190 / 210 6.7 / 6.5 1 / 220-240 / 50 3.01 3.41 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 34.0 / 32.0 / 30.0 49 / 47 / 45 66 4.4 840 x 288 x 840 24.6 PT-UMC1 Morning Fog 950 x 25 x 950 5.0

5.9 / 14.6 / 16.3 6.8 / 16.9 / 18.7 15.2 5.40 5.50 80 / 190 / 210 7.8 / 8.0 1 / 220-240 / 50 2.70 3.07 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 34.0 / 32.0 / 30.0 49 / 47 / 45 66 5.5 840 x 288 x 840 24.6 PT-UMC1 Morning Fog 950 x 25 x 950 5.0

UU37W UO2

UU49W U32

UU61W U32

Twin Rotary 90 53 54 66 950 x 1,170 x 330 85.0 R410A 2,800 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 68 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 71 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

14

CEILING CONCEALED DUCT

CEILING CONCEALED DUCTS E.S.P. CONTROL The BLDC motor and low noise fan means that air volume can be easily controlled by using the wired remote controller. The BLDC motor can control the fan speed and air volume regardless of the external static pressure(E.S.P.) With E.S.P control no additional accessories are needed to adjust the air flow and the energy consumption of the fan is also reduced. Air Volume

L

M

H

H M L

External Static Pressure * Applied to wired remote controller PQRCVSL0(QW)

HIGH HEAD DRAIN PUMP High head drain pump automatically drains water up to 700mm of drain-head height. It provides perfect solution for water drainage.

Fixture Drain pipe

Drain pipe slope (1/50~1/100)

450mm

Accessory (ABDPG)

700mm

Flexible drain hose

300mm

15

16

CEILING CONCEALED DUCT

STANDARD INVERTER

CEILING CONCEALED DUCTS TWO THERMISTORS CONTROL The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment.

OPERATION FOR MULTIPLE ROOMS BLDC motor delivers low indoor noise levels by using the high efficiency turbo fan. Anti vibration design reduces resonance noise.

Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users

Remote Controller Thermistor

Indoor Unit Thermistor

17

18

STANDARD INVERTER

STANDARD INVERTER

HIGH STATIC DUCT

HIGH STATIC DUCT

CB18 / CB24 / UB30

UB36 / UB48 / UB60

UU24W UU30W

UU18W

UU49W UU61W

UU37W

(Included PQRCVSLOQW)

(Included PQRCVSLOQW)

* CB18 / CB24 are compatible with SCAC and MULTI.

Indoor Capacity Low Temperature Capacity Power Input (Set)

Cooling Heating Heating -7°C Cooling Heating

Power Input (Indoor) Running Current Power Supply EER COP SEER SCOP Pdesign (@-10°C) Seasonal Energy Label Annual Energy Consumption Piping Connection Air Flow Rate Sound Pressure Sound Power Dehumidification Rate Dimensions Net Weight External Static Pressure

Cooling/Heating

Min/Nom/Max Min/Nom/Max Max Nom Nom Min/Nom/Max (ESP 2.5mmAq) Min/Max (ESP 8.0mmAq) Nom

kW kW kW kW kW W W A ø/V/Hz

kW Cooling/Heating Cooling/Heating Liquid Gas Drain Cooling Cooling Body Body

O.D./I.D. High/Medium/Low High/Medium/Low Max WxHxD Min~Max

kWh mm(inch) mm(inch) mm m3/min dBA dBA l/h mm kg mmAq(Pa)

Outdoor Compressor Airflow Rate Sound Pressure Sound Power Dimensions Net Weight Refrigerant Operation Range (Outdoor) Power Supply Power Supply Cable Transmission Cable Circuit Breaker Piping Length Total Piping Elevation Difference Piping Connection

Type Cooling Heating Cooling WxHxD

Nom Nom Nom Max

Type Charge Additional Charge (after 7.5m) Cooling Min~Max Heating Min~Max

IDU-ODU Liquid Gas

Min~Max Max

m3/min dBA dBA dBA mm kg g g/m °C DB °C WB ø/V/Hz No.xmm² No.xmm² A m m mm(inch) mm(inch)

CB18 NH2

CB24 NH2

UB30 NG2

2.0 / 5.0 / 5.4 2.4 / 6.0 / 6.6 5.4 1.54 1.66 50 / 70 / 70 90 / 120 6.7 / 7.2 1 / 220-240 / 50 3.21 3.61 4.61 3.81 3.8 B/A 377 / 1,400 ø 6.35 (1/4) ø 12.7 (1/2) 32 / 25 16.5 / 14.5 / 13.0 36 / 34 / 32 60 2.0 882 x 260 x 450 26.0 2.5~8(25~78)

2.8 / 7.1 / 7.8 3.2 / 8.0 / 8.8 7.2 2.36 2.49 50 / 80 / 80 100 / 140 10.3 / 10.8 1 / 220-240 / 50 3.01 3.21 5.11 3.81 6.0 A/A 487 / 2,211 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 18.0 / 16.5 / 14.0 36 / 35 / 33 61 2.5 882 x 260 x 450 26.0 2.5~8(25~78)

3.2 / 8.0 / 8.8 3.6 / 9.0 / 9.9 8.1 2.28 2.49 70 / 110 / 110 110 / 160 9.9 / 10.8 1 / 220-240 / 50 3.51 3.61 5.61 3.81 7.0 A+ / A 500 / 2,579 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 26.5 / 23.0 / 20.0 36 / 35 / 33 61 3.3 1,182 x 298 x 450 33.0 2.5~10(25~98)

Indoor

UU18W UE2

UU24W U42

UU30W U42

Outdoor

Twin Rotary 50 48 51 60 870 x 655 x 320 46.0 R410A 1,400 20 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 20 5~40 30 ø 6.35 (1/4) ø 12.7 (1/2)

Twin Rotary 58 48 52 62 950 x 834 x 330 60.0 R410A 2,000 40 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 30 5~50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 58 48 52 65 950 x 834 x 330 60.0 R410A 2,000 40 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 30 5~50 30 ø 9.52 (3/8) ø 15.88 (5/8

Compressor Airflow Rate

Capacity Low Temperature Capacity Power Input (Set)

Cooling Heating Heating -7°C Cooling Heating

Power Input (Indoor) Running Current Power Supply EER COP SEER SCOP Pdesign (@-10°C) Seasonal Energy Label Annual Energy Consumption Piping Connection Air Flow Rate Sound Pressure Sound Power Dehumidification Rate Dimensions Net Weight External Static Pressure

Sound Pressure Sound Power Dimensions Net Weight Refrigerant Operation Range (Outdoor) Power Supply Power Supply Cable Transmission Cable Circuit Breaker Piping Length Total Piping Elevation Difference Piping Connection

Cooling/Heating

Min/Nom/Max Min/Nom/Max Max Nom Nom Min/Nom/Max (ESP4.0mmAq) Min/Nom/Max (ESP10.0mmAq) Nom

kW kW kW kW kW W W A ø/V/Hz

kW Cooling/Heating Cooling/Heating Liquid Gas Drain Cooling Cooling Body Body

O.D./I.D. High/Medium/Low High/Medium/Low Max WxHxD Min~Max

kWh mm(inch) mm(inch) mm m3/min dBA dBA l/h mm kg mmAq(Pa)

Type Cooling Heating Cooling WxHxD

Nom Nom Nom Max

Type Charge Additional Charge (after 7.5m) Cooling Min~Max Heating Min~Max

IDU-ODU Liquid Gas

Min~Max Max

m3/min dBA dBA dBA mm kg g g/m °C DB °C WB ø/V/Hz No.xmm² No.xmm² A m m mm(inch) mm(inch)

Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB /19°C WB - Outdoor Temperature 35°C DB /24°C WB 3. Annual energy consumption: based on average use of 500 running hours per year at nominal condition

Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB /19°C WB - Outdoor Temperature 35°C DB /24°C WB 3. Annual energy consumption: based on average use of 500 running hours per year at nominal condition

Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB

Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB

19

UB36 NG2

UB48 NR2

UB60 NR2

4.0 / 10.0 / 11.0 4.5 / 11.2 / 12.3 10.0 3.06 3.20 110 / 160 / 160 160 / 220 4.4 / 4.6 1 / 220-240 / 50 3.27 3.50 4.71 3.81 7.6 B/A 745 / 2,800 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 32.0 / 29.0 / 26.0 42 / 39 / 36 61 4.0 1,182 x 298 x 450 38.0 4~10(39~98)

5.6 / 14.0 / 15.4 6.6 / 16.4 / 18.2 14.8 4.36 4.42 120 / 190 / 190 190 / 280 6.3 / 6.4 1 / 220-240 / 50 3.21 3.71 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 40.0 / 35.0 / 30.0 44 / 42 / 40 65 6.0 1,230 x 380 x 590 52.0 5~12(49~118)

5.9 / 14.8 / 16.3 6.8 / 16.8 / 18.7 15.2 5.09 4.53 190 / 300 / 300 300 / 430 7.3 / 6.5 1 / 220-240 / 50 2.91 3.71 ø 9.52 (3/8) ø 15.88 (5/8) 32 / 25 50.0 / 45.0 / 40.0 46 / 44 / 42 67 6.5 1,230 x 380 x 590 49.0 6~14(59~137)

UU37W UO2

UU49W U32

UU61W U32

Twin Rotary 90 53 54 66 950 x 1,170 x 330 85.0 R410A 2,800 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 68 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 71 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

20

CEILING & FLOOR / CEILING SUSPENDED

CEILING & FLOOR CEILING SUSPENDED FLEXIBLE INSTALLATION The ceiling and floor models can be installed either on the ceiling or on the floor. This saves space when installed in the shops or offices.

* Ceiling & Floor : CV09 NE2 / CV12 NE2

AIRFLOW DIRECTION CONTROL Vertical airflow direction can be adjusted using remote controller, and horizontal airflow direction can be adjusted manually.

Cooling

• Horizontal

Cooling

100°

Close

80°

• Vertical

Heating

93°

Heating

63° 21

Close

22

CEILING & FLOOR / CEILING SUSPENDED

CEILING & FLOOR CEILING SUSPENDED

STANDARD INVERTER

CEILING SUSPENDED

CV24 / UV36 UV48 / UV60

UV36

CV24

TWO THERMISTORS CONTROL UV48 , UV60

The indoor temperature can be checked using the thermistors in the remote controller as well as from the indoor unit. There may be a significant difference between ceiling and floor air temperature. Two thermistors can optimise indoor air temperature for a more comfortable environment. Compares temperatures sensed from different positions, and automatically selects the optimum temperature for users

UU24W

UU37W

UU49W UU61W

(Included PQWRHQ0FDB)

Indoor Unit Thermistor

*CV24 are compatible with SCAC and MULTI.

Indoor Capacity Low Temperature Capacity Power Input (Set)

Remote Controller Thermistor

Power Input (Indoor) Running Current Power Supply EER COP SEER SCOP Pdesign (@-10°C) Seasonal Energy Label Annual Energy Consumption

PQRCVSLOQW (Optional)

Piping Connection

ONE TOUCH FILTER

EZ REMOTE CONTROLLER

The filter change alarm informs you when the unit has been operating for 2,400 hours. It is very easy to clean or change the filter.

- Comfortable grip - Sliding type - Large buttons - Easy recognisable functions with graphics

Filter Alarm after 2400 hours of Unit working ※ model: VJ,VK,VL chassis

Filter Change Alarm

Air Flow Rate Sound Pressure Sound Power Dehumidification Rate Dimensions Net Weight

Cooling Heating Heating -7°C Cooling Heating Cooling/Heating

Min/Nom/Max Min/Nom/Max Max Nom Nom Min/Max Nom

kW kW kW kW kW W A ø/V/Hz

kW Cooling/Heating Cooling/Heating Liquid Gas Drain Cooling Cooling Body Body

O.D./I.D. High/Medium/Low High/Medium/Low Max WxHxD

kWh mm(inch) mm(inch) mm m3/min dBA dBA l/h mm kg

CV24 NJ2

UV36 NK2

UV48 NL2

UV60 NL2

2.8 / 7.0 / 7.7 3.1 / 7.6 / 8.5 6.9 2.18 2.37 40 / 60 9.5 / 10.3 1 / 220-240 / 50 3.21 3.21 5.51 3.81 5.8 A/A 445 / 2,137 ø 9.52 (3/8) ø 15.88 (5/8) 21.5 / 16.0 13.9 / 12.9 / 11.9 44 / 43 / 41 61 3.2 950 x 650 x 220 23.0

3.8 / 9.5 / 10.5 4.2 / 10.5 / 11.6 9.4 2.78 3.08 40 / 90 4.0 / 4.4 1 / 220-240 / 50 3.42 3.41 5.11 3.81 7.6 A/A 652 / 2,800 ø 9.52 (3/8) ø 15.88 (5/8) 21.5 / 16.0 21.4 / 19.8 / 18.2 45 / 44 / 41 63 3.5 1,350 x 650 x 220 34.1

5.3 / 13.3 / 14.6 6.4 / 15.3 / 17.6 14.3 4.28 4.49 90 / 140 6.2 / 6.5 1 / 220-240 / 50 3.11 3.41 ø 9.52 (3/8) ø 15.88 (5/8) 21.5 / 16.0 30.0 / 28.3 / 26.6 47 / 46 / 44 63 5.8 1,750 x 650 x 220 42.5

5.7 / 14.4 / 15.7 6.8 / 16.8 / 18.7 15.2 5.24 5.42 100 / 150 7.6 / 7.9 1 / 220-240 / 50 2.75 3.10 ø 9.52 (3/8) ø 15.88 (5/8) 21.5 / 16.0 31.5 / 29.7 / 28.0 48 / 47 / 45 63 6.2 1,750 x 650 x 220 42.5

UU24W U42

UU37W UO2

UU49W U32

UU61W U32

Twin Rotary 58 48 52 62 950 x 834 x 330 60.0 R410A 2,000 40 -15 ~ 48 -18 ~ 18 1 / 220-240 / 50 3C x 2.5 4C x 0.75 30 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 90 53 54 66 950 x 1,170 x 330 85.0 R410A 2,800 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 50 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 68 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

Twin Rotary 110 52 54 71 950 x 1,380 x 330 96.0 R410A 3,400 40 -15 ~ 48 -18 ~ 18 3 / 380-415 / 50 5C x 2.5 4C x 0.75 20 5 ~ 75 30 ø 9.52 (3/8) ø 15.88 (5/8)

Outdoor Compressor Airflow Rate Sound Pressure Sound Power Dimensions Net Weight Refrigerant Operation Range (Outdoor) Power Supply Power Supply Cable Transmission Cable Circuit Breaker Piping Length Total Piping Elevation Difference Piping Connection

Type Cooling Heating Cooling WxHxD

Nom Nom Nom Max

Type Charge Additional Charge (after 7.5m) Cooling Min~Max Heating Min~Max

IDU-ODU Liquid Gas

Min~Max Max

m3/min dBA dBA dBA mm kg g g/m °C DB °C WB ø/V/Hz No.xmm² No.xmm² A m m mm(inch) mm(inch)

Note : 1. Due to our policy of innovation some specifications may be changed without notification. 2. Capacities are based on the following conditions: Cooling : - Indoor Temperature 27°C DB /19°C WB - Outdoor Temperature 35°C DB /24°C WB 3. Annual energy consumption: based on average use of 500 running hours per year at nominal condition Heating : - Indoor Temperature 20°C DB / 15°C WB - Outdoor Temperature 7°C DB / 6°C WB

One touch Filter 23

24