Chemical Storage Cabinet

Chemical Storage Cabinet Models: CS6, CS12 Operators Manual Issue 04 – January 2012 Puricore International Ltd 175 Kenn Road Clevedon North Somerset...
Author: Doreen Jacobs
33 downloads 2 Views 383KB Size
Chemical Storage Cabinet Models: CS6, CS12

Operators Manual Issue 04 – January 2012

Puricore International Ltd 175 Kenn Road Clevedon North Somerset BS21 6LH Tel +44 1275 793000 | Fax +44 1275 341313 | [email protected] | www.puricore.com Registered in England No: 2695450

CE Marking certifies that this equipment conforms to the following EEC directives: Low Voltage Equipment – 72/23/EEC & 93/68 EEC Electromagnetic Compatibility – 89/336/EEC

Certificate No: 0954499

CONTENTS INTRODUCTION ....................................................................................................... 3 SPECIFICATION ....................................................................................................... 4 INSTALLATION ......................................................................................................... 5 CONTROL PANEL ..................................................................................................... 6 FILTERS ................................................................................................................... 7 PARTICULATE FILTER ..................................................................................................................................... 7 MAIN ACTIVATED CARBON FILTER ................................................................................................................. 7

FILTER REMOVAL AND FITTING ............................................................................... 8

FITTING THE FILTER ........................................................................................................................................ 8 DATE OF INSTALLATION ................................................................................................................................. 8

MONITORING ........................................................................................................... 9 PRE-FILTER ..................................................................................................................................................... 9 MAIN FILTER .................................................................................................................................................... 9 FREQUENCY OF SATURATION TESTING ......................................................................................................... 9 THE GENERAL PROCEDURE ............................................................................................................................ 9

SERVICING............................................................................................................. 10 MAINTENANCE....................................................................................................... 11

FILTERS ..........................................................................................................................................................11 LOW AIRFLOW ALARM ....................................................................................................................................11 FAN.................................................................................................................................................................12

FAULT FINDING ...................................................................................................... 13

Chemical Storage Cabinet

Operators Manual

INTRODUCTION The Labcaire Chemical Storage Cabinet is a recirculatory fume cabinet that has been designed for use in laboratories and requires no connection to ducting. The storage cabinet has grey tinted acrylic doors and is normally used for formalin containers. The Airflow System has an Activated carbon filter for the removal of formalin fumes. Contact Puricore if chemicals other than formalin are to be stored in the cabinet. During use the filters will absorb chemicals and particulates and the cabinet must be inspected at least every 14 months to ensure it is operating satisfactorily and to comply with C.O.S.H.H. regulations (Control of Substances Hazardous to Health). A low airflow alarm is fitted to indicate when the pre-filter requires changing. Please keep this manual in an accessible but secure place. Further copies are available from Puricore if required.

CS6

3

Chemical Storage Cabinet

Operators Manual

SPECIFICATION The cabinet is constructed of Zintec coated steel epoxy powder coated for maximum corrosion protection. All glazing is in 6mm clear acrylic with polished edges. The shelving is manufactured from steel and is height adjustable. Noise