Characteristics Zelio Relay plug-in relays 0 Universal relays

Zelio Relay plug-in relays Characteristics 0 Universal relays Relay type RUN 21C RUN 31C RUN 21D RUN 31A RUN 33D 3 C/O 2 C/O 3 C/O A 2 C...
Author: Arleen Thompson
0 downloads 1 Views 510KB Size
Zelio Relay plug-in relays

Characteristics

0

Universal relays

Relay type

RUN 21C

RUN 31C

RUN 21D

RUN 31A

RUN 33D

3 C/O

2 C/O

3 C/O

A

2 C/O AgNi 10

10

3 C/O linked Hard silver, 10 µ gold-flashed 4

V V VA

36 000 3600 20 "/$ 250 3000

36 000 3600 20 "/$ 250 3000

36 000 3600 10 " 250, $ 125 1000

Contact characteristics Number and type of contacts Contact materials Conventional rated thermal current (Ith) Maximum operating rate In operating cycles/h

For temperature 6 40°C No-load Under load Minimum Maximum

Switching voltage Maximum breaking capacity

Coil characteristics Rated voltage (Un) Average consumption

Inrush Sealed

Permissible voltage variation Drop-out voltage threshold

" $ " " $

V V VA VA W

" $

24, 48, 110, 230, 50/60 Hz (Other voltages available on request) 12, 24, 48, 110 (Other voltages available on request) 3.5 3.5 3.5 2.3 2.3 2.3 1.5 1.5 1.5 0.8…1.1 Un (50 Hz or $), 0.85…1.1 Un (60 Hz) ≥ 0.15 Un ≥ 0.15 Un ≥ 0.15 Un ≥ 0.05 Un

Environment Conforming to standards Approvals (pending) Ambient air temperature around the device

Standard version Standard version Storage Operation

Vibration resistance

Conforming to IEC EN 68-2-6

Degree of protection Shock resistance Mechanical durability Operating time (response time)

" $

In millions of operating cycles " Between coil energisation and $ making of the On-delay contact " Between coil de-energisation and $ making of the Off-delay contact Resistive load Inductive load

Electrical durability In millions of operating cycles/h

°C °C °C

EN 61810-1 UL, CSA - 40…+ 70 - 20…+ 40 - 20…+ 60 4 gn (30…100 Hz)

ms ms

IP 40 10 gn 20 About 15 About 15

ms ms

About 15 About 15 ≥ 0.1 to 10 A See curves below

Insulation characteristics Rated insulation voltage (Ui) Insulation class Dielectric strength (rms voltage)

Conforming to IEC 947 Conforming to VDE 0110 Between coil and " contact Between poles Between contacts "

Durability in N (230 V, 50 Hz)  Durability (number of operating cycles)

10 7

V V V V

250 C250, B380 2500 2500 1000 Switching capacity on a $ supply for minimum durability of: 106 operating cycles (resistive or inductive load with diode RVW 040BD). 6 4 3 2 1,5 1

5x10 6 2x10 6 10 6

2

5x10 5

1

2x10 5 10 5 5x10 4

1

2

3

0,6 0,4 0,3 0,2 0,1

10 20

50 10 2 2x10 2

10 3 5x10 3 VA 2x10 3

0 20

60

100

140

200

Switching capacity

1 Contact 2 Contacts in series 3 Contacts in series

1 Resistive load 2 Inductive load

References: page 28043/3

28043_Ver1.00-EN.fm/2

Dimensions: page 28046/3

Schemes: page 28047/3 Schneider Electric

Zelio Relay plug-in relays

References

0

Universal relays

References 560592

Relays for standard applications Number of C/O contacts

RUN 31C22// + RUZ 1C

2

Conventional rated thermal current A 10

3

10

LED

Pins

Sold in lots of

without Octal 8 flat pins Green Octal 8 flat pins Without Undecal 11 flat pins Green Undecal 11 flat pins

10 10 10 10 10 10 10 10

Unit reference, to Weight be completed by adding the control voltage code (1) kg RUN 21D21// 0.105 RUN 21C21// ? 0.105 RUN 21D22// RUN 21C22// ? RUN 31A21// 0.105 RUN 31C21// ? RUN 31A22// 0.105 RUN 31C22// ?

10

RUN 33A22//

Relays with gold-flashed contacts 3

4

Green Undecal

0.105

LED indicator modules Voltage

560593

Description

Sold in lots of

Unit reference

110/230 6/24

20 20

RUW 010P7 RUW 030BD

kg 0.006 0.006

$ " " "

6…220 24 230 110…240

20 20 20 20

RUW 040BD RUW 042B7 RUW 042P7 RUW 041P7

0.006 0.006 0.006 0.006

7

24…240

1

RUW 101MW

0.020

Unit reference RUZ 1D RUZ 1A

Weight kg 0.067 0.067

V " $ With protection diode

“Power on” indication

Weight

Protection module Diode Varistor RC circuit

Timer modules

RUN 31A21// + RUZ 1A

Multifunction

Sockets

560594

Protection module Without

With

Application

I/O

RUN 21 octal RUN 31 and RUN 33 undecal RUN 21C and RUN 31C RUN 31 and RUN 33 RUN 21 octal

Mixed Mixed

Sold in lots of 10 10

Mixed

10

RUZ 1C

0.067

Mixed Mixed

10 10

RUZ 7D RUZ 7A

0.069 0.069

Sold in lots of 25

Unit reference

Accessories Description

RUN 33A22// + RUW 101MW + RUZ 7A

Maintaining clamp (1) Standard control circuit voltages Volts 12 24 48 $ RUN 21 and RUN 31 JD BD ED RUN 33 – BD ED " 50/60 Hz RUN 21, RUN 31 – B7 E7 and RUN 33 For other voltages, please consult your Regional Sales Office.

RUZ 200 110 FD – F7

Weight kg 0.001

230 – – P7

560590

Coil characteristics Control circuit voltage Uc RUZ 200

Characteristics: page 28043/2 Schneider Electric

V 12 24 48 110 230

Dimensions: page 28046/3

d.c. supply Average resistance at 20 °C ± 10% Ω 96 384 1336 7660 –

Cod. Operating voltage limits Min Max

JD BD ED FD –

V 9.6 19.2 38.4 88 –

V 19.2 26.4 52.8 121 –

a.c. supply, 50/60 Hz Average Cod. Operating resistance voltage limits at 20 °C Min Max ± 15 % Ω V V – – – 73.7 B7 204 26.4 305 E7 408 54.8 1710 F7 93.5 121 7500 P7 196 253

Schemes: page 28047/3

28043_Ver1.00-EN.fm/3

Zelio Relay plug-in relays

Schemes

0

Interface relays RSB 1A120//

3

8

5

7

4

6

3

1

3

4

2

6

5

1

4

2

5

7

1

8

RSB 1A160//

2

RSB 2A080//

When using relay RSB 1A160// with socket RSZ E1S48M, terminals 11 and 21, 14 and 24, 12 and 22 must be linked.

Miniature relays RXN 21E1///

RXN 41G

1

4

1

2

3

4

12 5

42 8

12 5

22 6

32 7

42 8

14 9

44 12

14 9

24 10

34 11

44 12

11 13

41 14

11 13

21

31

41 14

A1

A2

A1

RXL 2//

A2

RXL 3//

RXL 4//

1

4

1

2

3

1

2

3

4

12 5

42 8

12

22

32

4

5

6

12 5

22 6

32 7

42 8

14 9

44 12

14 7

24 8

34 9

14 9

24 10

34 11

44 12

11 13

41 14

11 13

21

31 14

11 13

21

31

41 14

A1

A2

A1

A2

A1

References : pages 28041/3 et 28042/4

28047_Ver1.00-EN.fm/2

A2

Dimensions : page 28046/2 Schneider Electric

Schemes (continued)

Zelio Relay plug-in relays

0

Universal relays

RUN 21D2/// 12 4 14

34 31

24 21

32

14

22

12

11

A2

A1

24

RUN 31A2///, RUN 33A2/// RUN 31C2///

21

14

22

11

A2

A1

12

RUN 21D2///, RUN 21C2///

RUN 33A2/// 21 6

22 22

5

24 7

5

3

6

2

7

24

12

4

14 3 A1

+

9 34

A2 A1

1 11

8

2

+

21

RUN 21C2///

32

8

10

A2

11

1 11

31

RUN 31C2///

1

3

1

2

3

12

22

12

32

22

4

6

4

5

6

14 7

24 9

14 7

34 8

24 9

11 A (+)

21 B ( )

11 A (+)

31

21 B ( )

A1

A2

A1

References : page 28043/3 Schneider Electric

A2

Dimensions : page 28046/3

28047_Ver1.00-EN.fm/3

Zelio Relay plug-in relays

Dimensions

0

Interface relays (References: page 28041/3) RSB 2A080//, RSB 1A160//

12,5 7,5

15,7

5

3,9

2,5

3,5

5

Sockets RSZ E1S48M

2,5

3,5

RSZ E1S35M

67

67 (4)

Ø 3,2

29,4

(2) 34,5 50

Ø 3,2

(1)

75

(1)

(4)

61

(3)

78,5

61

(3)

29 16,5

29,4

3,9

RSB 1A120//

29 15

12,5 7,5

15,7

(2)

34,5 50

15,5

15,5

Miniature relays (References: pages 28042/4 and 28042/5)

27,5

RXN 21E1///, RXN 41G1///,RXL

21,1

35,6 41,8 Sockets RXZ 7G

RXZ E1S108M

(4)

82 61

=

19

(4)

83

3,2 75

(1) =

(2)

78,5

73,5

2xØ3,3

(2)

(3) 22

37,4 41,5

55

RXZ E1S111M

27

RXZ E1S114M, RXZ E1M114M

82 (4)

(2)

75 (3)

29

3,2

(1)

83

75

(1)

(2)

22,5

55

27

(4)

61

3,2

61

83

82

(3)

22,5

29

27

29 55

22,5 27

(1) Relays, (2) Add-on protection module, (3) Maintaining clamp, (4) Legend. References: pages 28041/3 and 28042/4

28046_Ver1.00-EN.fm/2

Schemes: page 28047/2 Schneider Electric

Zelio Relay plug-in relays

Dimensions (continued)

0

Universal relays (References: page 28043/3) RUN 21C2/// RUN 31C2///

24

37

37

RUN 21D2/// RUN 31A2/// RUN 33A2///

35,5

55

35,5

59 66,5

Sockets RUZ 1D

25

= 8

29,5

3,5

29,5

3,5

22

=

=

8

66,5

=

RUZ 1A

37,5

=

RUZ 7A

=

RUZ 7D

37,5

2x 3,2

=

=

75

75

2x 3,2

22,5

30

22,5

30

26

38

26

38

=

RUZ 1C

=

72

2x 4

23

37,5

26

45

References: page 28043/3 Schneider Electric

Schemes: page 28047/3

28046_Ver1.00-EN.fm/3

Suggest Documents