Changing dermatology forever. PicoSure

PicoSure ™ Changing dermatology forever Unprecedented innovation in laser technology. PicoSure, the world’s first safe and effective picosecond ae...
Author: Collin Gilbert
28 downloads 0 Views 4MB Size
PicoSure



Changing dermatology forever

Unprecedented innovation in laser technology. PicoSure, the world’s first safe and effective picosecond aesthetic laser, has arrived. This unparalleled breakthrough in laser technology delivers ultra-short pulse bursts of energy to the skin in trillionths of a second. Picosecond pulse width is 100 times shorter than nanosecond technology, enabling unmatched photomechanical impact for better clearance with fewer treatments.

The future is here.

PicoSure Changing dermatology forever

Typical American tattoo patient1: • Female ~ 69%

• College educated

• Single

• 24-39 years old

45  million 2

20% m

i

l

l

i

o

n

regret factor

32% increase of tattoo removal procedures in 20114 (by aesthetic physicians)

Employment concerns cited by 40% as reason for tattoo removal5

32%

g row th

3

Shattering the past. Revealing the future. PicoSure is the first and only aesthetic picosecond laser for the safe and effective removal of tattoos and benign pigmented lesions. PicoSure’s ultra-short pulse duration goes beyond photothermal action creating an intense photomechanical impact, patented PressureWave™, resulting in greater disruption of the target for better clearance with fewer treatments, less fluence and without injury to the surrounding skin. Even dark, stubborn blue and green inks, as well as previously-treated, recalcitrant tattoos can be removed.

Picosecond vs. nanosecond technology Traditional nanosecond lasers predominately rely on photothermal action, delivering heat to the pigment and surrounding tissue.

PicoSure takes advantage of PressureWave Technology to shatter the target ink into tiny particles that are easily eliminated by the body.

Ultra-short Pulse Duration Is the Difference • Picosecond pulse width is 100X shorter than nanosecond technology. • Only ultrashort pulse durations trigger photomechanical effect. •W  ith this short pulse width, half the fluence is required compared to Q-Switched nanosecond lasers.

UNTREATED INK

TRADITIONAL LASER

PICOSURE LASER

Laser response comparison Electron Microscopy images courtesy of H.R. Jalian, M.D.

Q-Switched Picosecond

TATTOO BEFORE

AFTER 1 MONTH, 3 TX Photos courtesy of Cynosure, Inc.

Clinical data shows

better results in fewer treatments, even with recalcitrant tattoos . 6

Recalcitrant tattoo

TATTOO BEFORE

PIGMENTED LESION BEFORE

Photos courtesy of Cynosure, Inc.

AFTER 20 Tx Q-SWITCHED Nd:YAG

AFTER 1 Tx PICOSURE

Photos courtesy of Roy G. Geronemus, MD

TATTOO BEFORE

AFTER 6 Tx PICOSURE

AFTER 3 Tx PICOSURE

Photos courtesy of Roy G. Geronemus, MD

General Specifications Nominal Wavelength

755nm

Pulse Duration

750ps

Pulse Energy

200mJ

Electrical Power

200-240 V~,4.5 kVA, 50/60Hz, single phase

Electrical Service Requirement

30Amp

Handpiece Specifications Zoom Handpiece Spot Size

2.0–6.0mm

Fixed Handpieces Spot Size

6.0, 8.0, 10.0mm

For the power of PicoSure contact your Cynosure consultant today. Call 800-886-2966. Visit www.picosure.com REFERENCES: 1. http://esciencenews.com/articles/2008/07/21/study. examines.motivations.tattoo.removal 2. Harris Interactive, 2012 3. H  arris Interactive, 2013 4. P  atient’s Guide survey, published May 22, 2012, http://blog.patientsguide.com/2012/05/study-tattooremoval-climbs-32-in-competitive-job-market/

6. S uccessful and Rapid Treatment of Blue and Green Tattoo Pigment With a Novel Picosecond Laser, Jeremy A. Brauer, MD; Kavitha K. Reddy, MD; Robert Anolik, MD; Elliot T. Weiss, MD; Julie K. Karen, MD; Elizabeth K. Hale, MD; Lori A. Brightman, MD; Leonard Bernstein, MD; Roy G. Geronemus, MD

5. ABC News, May 2012

INVISIBLE LASER RADIATION © 2 013 Cynosure, Inc. Cynosure is a registered trademark and PicoSure is a trademark of Cynosure, Inc. PicoSure and PressureWave are trademarks of Cynosure, Inc. 921-0415-000 Rev. 1 02/13

AVOID EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION. EN 60825-1: 2007 CLASS 4 LASER PRODUCT SOLID STATE LASER Pulse Energy: Pulse Width: Wavelength:

200mJ ≤ 900ps 755nm

AIM LASER CLASS–3R Maximum Power: