Novkabel AD Industrijska bb, 21000 Novi Sad, Republic of Serbia Tel: +381 21 21 00 520 +381 21 21 00 521 Fax: +381 21 21 00 522 e-mail:
[email protected] www.novkabel.com
CABLES AND WIRES
Francuska 6, 11000 Belegrade, Republic of Serbia Tel: + 381 11 33 46 444 Fax: +381 11 32 34 431 e-mail:
[email protected] www.point-group.com
Novi Sad, Republic of Serbia
Certificate
Sale Centers H03VV-F H03VVH2-F H05VV-F
H05RN-F
Novkabel AD Serbia, 21000 Novi Sad Industrijska bb Тel: +381 21 21 00 520 Fax: +381 21 21 00 522 e-mail:
[email protected] www.novkabel.com Western Europe Representative: DP Handel GmbH Westendstrasse 24 D-60325 Frankfurt am Main, Germany Tel: + 44 69 97 14 810 Fax: + 44 69 97 14 81 15 e-mail:
[email protected]
H05V-U H05V-K H07V-U H07V-R H07V-K
Moscow Representative: Российская Федерация, 123100 Москва Ул. Мантулинская, дом 5, стр. 3 Тел: + 7 499 244 06 15/16 Факс: + 7 499 244 08 03 e-mail:
[email protected]
Content POWER CABLES...............................................002 POWER CONDUCTORS...............................034 SIGNAL CABLES...............................................046
RUBBER CABLES............................................058 TELECOMUNICATION CABLES...............090 ELECTRONIC CABLES...................................122 AUDIO CABLES................................................134 HALOGEN FREE CABLES............................142
COAXIAL CABLES.........................................176 OVERHEAD LINES......................................180 METAL PRODUCTS........................................194 TECHNICAL DATA...........................................208
TM 20
098
H05Z
145
059
TC 44
099
H07Z
146
H05RR-F
060
TI 44
100
H07ZZ-F
147
007
H05RN-F
061
TZ 44
101
NHXMH
148
N(A)YRGY
009
NFK EpG
062
TSV
102
N2XH
149
N(A)YFGY
011
NFK TES
063
TK 33 U
103
N2XH FE 180
150
N(A)2XY
013
ZEpN, BT, HT
064
TK 39 M, GM
104
N2XSH
151
N(A)2XBY
015
NSGAFöu
065
TK 59 M, GM
105
N2XS(E)H
152
N(A)2XRGY
017
KPSRM
066
TK 59 TP
106
NHXHX
153
N(A)2XFGY
019
PPSRVM
067
TK 59 GMR
107
NHXHX FE 180
154
N(A)YSY
021
068
TPP
108
NHXCHX
155
WIRE OF ALUMINIUM
195
PPSRMO
N(A)YSEY
022
NGFLGöu
069
TPPEP
109
NHXCHX FE 180
156
COPPER WIRE
196
N(A)YSEYBY
023
NFK SiSi/JU
070
A-02Y(L)2Y
110
LiHXHX
157
024
NSHTöu
071
A-2Y(L)2Y
111
LiHXHX FE 180
158
TINNED COPPER WIRE
197
N(A)YSEYRGY N(A)YSEYFGY
025
Si/F
072
A-2YF(L)2Y
112
LiHXCHX
159
198
N(A)2XSY
026
NFK SiSi/J
073
TD 59 UP
113
LiHXCHX FE 180
160
ALUMINIUM CONDUCTORS
N(A)2XSEY
027
NSSHöu
074
TD 59M, GM
114
ILAN 120 (ohm) H 161
199
N(A)2XS(F)2Y
028
NFK EpN 50
075
TB-TZB
115
J-02Y(St)H
162
COPPER CONDUCTORS
XHEh 91
029
H07RN-F
TG-TZG
J-2Y(St)H
163
BRAIDED COPPER ROPES
201
076
116
N(A)2XSYBY
030
NSSHöu.../3E
077
S-YY
117
TC 88 K (EK)
164
N(A)2XSYRGY
031
NSSHöu...KON
078
S-Y(ST)Y
118
TZ 88 E (GE)
166
N(A)2XSYFGY
032
EpN 58
079
TO SM 03
119
THI
167
202 CONDUCTORS FOR MEASURING TRANSFORMERS
NSSHCGEöu...+üI 080
TO SM 19
120
THM
168
FLAT BRAIDS
203
NSSHCGEöu.../3
ELECTRONIC CABLES
J-HH
169
BRASS WIRE
204
NSSHCGEöu...+St+ üI 082
Y
123
J-H(St)H
170
205
NSSHCGEöu.../ KON+St+üI
083
YV
124
JE-H(St)H FE 20
171
WIRE FOR EROSIMATE
6Y
125
JE-H(St)H FE 180
172
NTSCGECWöu... KON
084
7Y
126
173
085
127
NTSCGECWöu... KON
LiY, LiY-T
MGH, MGCH, FMGCH
Li6Y
128
174
NTSCGERWöu... KON
086
Li7Y
129
LiYY, So-LiYY
130
NFK MGH, NFK MGCH, NFK FMGCH
NTSCGEWöu.../3
087
LiYCY, So-LiYC Y
131
NTSCGEWöu.../ 3E+St+ üI
088
LiYCY, So-LiYC Y
132
MGG,MGCG, FMGCG
089
RUBBER CABLES
POWER CABLES
N(A)YY
003
H01N2-E, -D
N(A)YCY
005
N(A)YBY
POWER CONDUCTORS H07V-U, -R
035
NYM
036
PP-R
037
PP-U
038
H07V-K
039
H03VH-H
040
H03VV-F
041
H05VV-F
042
PP-JZ
043
H05VVH6-F
044
SIGNAL CABLES
081
AUDIO CABLES
NYY
047
NYBY
048
NYRGY
049
NYSY
050
TELECOMUNICATION CABLES
N2XY
051
TK59 DSL
091
NYSLY
052
TK59 DSL -120
092
NYSLYCY
053
2YY
093
NYSLYÖ(H05VV5-F)
054
J-YY
094
NYSLYCYÖ(H05VVC4V5-F)
055
J-Y(ST)Y
095
HALOGEN FREE CABLES
SEZ
056
JE-Y(ST)Y
096
LiHH
143
057
TI 20
097
LiHCH
144
SPZ
NAUK 001
135
NAUK 100
136
NAUK 102
137
NAUK 200
138
NAUK 300
139
NAUK 900, 905
140
NAUK 901, 904
141
COAXIAL CABLES RG 50
177
RG 75
178
OVERHEAD LINES Alumoveld Conductors
181
AlMgSi Conductors
182
Aluminium Conductors
183
Al/steel Conductors
184
Hard copper and 186 bronze ropes
Protective ropes for transmission lines
187
PP/O
188
X00-A
189
X00/O-A
190
СИП 3
191
XHP 48/O-A; XHE 192 49/O-A METAL PRODUCTS
TECHNICAL DATA Proporties of materials used for cables production
209
Halogen-free flame retardant materials
210
Conductor resistance
213
Core marking
215
Nominal voltage
218
CURRENT LOAD
219
Transport reels
235
Laying of Cables
238
Company Profile About us
Objective
The Cable Factory based in Novi Sad was established in 1921 and represents the oldest cable factory in the Balkans. We supply a wide range of energy cables and conductors, telecommunication cables and cables for electronic equipment to suit various industrial needs of construction industry, mining, shipbuilding, as well as oil, transportation, automotive industry and other industries.
NOVKABEL focuses on quality with utmost respect of the client’s needs producing cables in accordance with the quality standards and ecology requirements. Our goal is to remain the leading company in production and distribution of all types of cables by improving the sales, conquering new markets, expanding the distribution network and strengthening the relations with business partners.
NOVKABEL, a member of
Novkabel production plant occupies an area of almost 40 hectares in the industrial zone of Novi Sad with the production capacity of up to 35.000 tons per year.
Capacity
Research and development Point Group is the leading regional group with subsidiaries and associated companies that operate mainly in South East Europe. The core business activities of the Point Group are: copper processing and trading, wholesale grain trading, mill and bakery industry, river transport, real estate and engineering. The major part of the business activity has been conducted in Serbia, Romania, Hungary and Austria. Point Group also has its branch offices in the following leading business centers: Moscow, New York, Frankfurt and Beijing.
NOVKABEL IS A RECOGNIZABLE PRODUCTION BRAND IN CABLE INDUSTRY THROUGHOUT SOUTHEASTERN EUROPE, WITH THE POSITION OF THE LEADING PROVIDER REGARDING THE QUALITY AND RANGE OF PRODUCTS.
From its modest beginnings in the product range, with the work of generations of employees on the development of new products, the factory has achieved about 16.000 registered products. NOVKABEL experts dedicate significant amounts of time to follow and implement the latest technical and technological achievements in cable production. Quality We carry out all quality control procedures to ensure that all raw materials meet intake specifications and follow production until the dispatch of finished products; therefore, the investment into control equipment is one of Novkabel’s priorities.
POWER CABLES N(A)YY N(A)YCY N(A)YBY N(A)YRGY N(A)YFGY N(A)2XY N(A)2XBY N(A)2XRGY N(A)2XFGY N(A)YSY
003 005 007 009 011 013 015 017 019 021
N(A)YSEY N(A)YSEYBY N(A)YSEYRGY N(A)YSEYFGY N(A)2XSY N(A)2XSEY N(A)2XS(F)2Y XHEh 91 N(A)2XSYBY N(A)2XSYRGY N(A)2XSYFGY
022 023 024 025 026 027 028 029 030 031 032
[Type text]
PP 00, PP 00-A
ВВГ, АВВГ; NYY, NAYY
Power cables with PVC insulation and sheath Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type PP 00, or aluminium: type PP 00-A. Insulation: PVC compound. Core: two or multi cores are stranded together. Fillig: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Cables with sector shaped conductors (designated S in table) wrapped thermoplastic tapes. Sheath: PVC compound. Sheat colour black.
APPLICATION
For laying indoors, in ducts, in earth, in the open air, in urban networks and industrial plants, electric power plants and switchgear assemblies, where one cannot expect mechanical damages.
CONSTRUCTION DATA Construction1) 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 3x1,5 3x2,5
Cu number
Al number
PP00 [kg/km] 14,4 24 38 58 96 154 240 336 480 672 912 1152 1440 1778 2304 29 48 77 115 192 307 480 43 72
PP00-A [kg/km] 12 18 29 46 72 102 145 203 276 348 435 537 696 23 36 58 93 145 -
Diameter [mm] 7,0 7,5 8,0 8,5 9,5 11,0 13,0 13,5 15,5 17,5 19,0 20,5 22,5 24,5 28,0 10,5 11,5 13,0 14,5 16,5 19,0 22,0 11,0 12,0
Mass PP00 65 82 105 125 174 252 363 475 637 850 1115 1365 1707 2056 2657 150 197 270 365 494 683 1005 171 227
[kg/km] PP00-A 78 89 110 143 204 251 316 398 516 617 736 896 1131 235 277 350 467 688 -
003
Construction
004
*
1)
Cu number
Al number
PP00
PP00-A
Diameter
Mass
[kg/km]
[kg/km] [kg/km] [mm] PP00 3x4 115 35 14,0 307 3x6 173 52 15,0 400 3x10 288 87 17,0 570 3x16 461 139 20,5 851 3x25* 720 218 23,0 1246 3x35* 1008 305 27,0 1686 S 3x50 1440 435 25,0 1715 S 3x70 2016 609 28,5 2391 S 3x95 2736 827 32,5 3251 S 3x120 3456 1044 35,5 4037 S 3x150 4320 1305 39,5 4928 S 3x185 5328 1610 43,5 6127 S 3x240 6912 2088 49,0 7983 3x25+16* 874 263 24,5 1278 * 3x35+16 1162 351 27,0 1627 S 3x50+25 1680 507 29,0 2105 S 3x70+35 2352 711 30,0 2760 S 3x95+50 3216 972 34,5 3794 S 3x120+70 4128 1247 38,0 4755 S 3x150+70 4992 1508 41,0 5645 S 3x185+95 6240 1888 48,5 7361 S 3x240 +120 8064 2436 54,0 9492 4x1,5 58 12,0 201 4x2,5 96 13,0 270 4x4 154 46 15,0 378 4x6 230 70 16,5 483 4x10 384 116 18,5 692 4x16 614 186 22,0 1044 4x25 960 290 25,5 1542 4x35 1344 406 28,5 2011 S 4x50 1920 580 29,5 2380 S 4x70 2688 812 33,0 3144 S 4x95 3648 1102 38,5 4381 S 4x120 4608 1392 41,5 5310 S 4x150 5760 1740 46,0 6569 S 4x185 7104 2148 51,0 8127 S 4x240 9216 3480 58,0 10560 5x1,5 72 12,5 238 5x2,5 120 14,0 323 5x4 192 58 16,5 455 5x6 288 88 17,5 582 5x10 480 145 20,5 838 5x16 768 233 24,0 1275 5x25 1200 363 28,5 1925 It is possible to produce construction sector shape according to customer requirement.
1)
PP00-A 284 306 391 530 736 930 853 1095 1438 1742 2128 2597 3363 850 1109 1019 1340 1715 2019 2433 3046 3903 298 354 456 591 909 1210 1103 1356 1883 2248 2737 3430 4404 352 421 546 729 1226
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: single core cables 15D; multi core cables 12D (D – cable diameter).
PP 40, PP 40-A
ВВГЭ, АВВГЭ; NYCY, NAYCY
Power cables with electrical protection Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type PP 40, or aluminium: type PP 40-A. Insulation: PVC compound. Core: two or multi cores are stranded together. Fillig: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Concentric conductor: wrapped annealed copper wires with contra-helical annealed copper tape or wrapped copper tape. Sheath: PVC compound. Sheat colour black.
APPLICATION
For laying in earth, indoors, in duckt, in open air in urban networks, for connection of home devices and public illuminations, industrial plants and electric power plants where cables expected to provide electrical protection. Concentric conductor could be used as neutral or protective conductor.
CONSTRUCTION DATA Construction1)
Cu number
Cu number
Al number
PP40
PP40-A
PP00-A
[kg/km]
[kg/km]
Diameter
Mass
005
[kg/km]
[kg/km]
[mm]
PP40
2x4/4
123
27
23
16,0
363
PP40-A 289
2x6/6
182
44
36
17,0
428
349
2x10/10
312
64
58
19,0
593
442
2x16/16
489
100
93
22,0
866
571
2x25/25
763
162
145
26,0
1310
876
3x4/4
161
27
35
16,5
410
316
3x6/6
240
44
52
18,0
518
383
3x10/10
408
62
87
20,0
718
483
3x16/16
643
102
139
23,0
1036
635
3x25*/16
902
102
218
27,5
1443
911
3x35*/16
1190
102
305
29,0
1930
1080
S 3x50/25
1723
157
435
29,0
2065
1062
S 3x70/35
2410
208
609
31,5
2800
1360
S 3x95/50
3296
288
827
37,0
3823
1825
S 3x120/70
4236
384
1044
40,0
4823
2196
Construction1)
Al number
PP40-A
PP00-A
[kg/km]
[kg/km]
Diameter
Mass
[kg/km]
[mm]
PP40
420
1305
42,5
5602
2612
S 3x185/95
6383
563
1610
48,0
7290
3303
S 3x240/ 120
8242
773
2088
53,5
9085
4190
3x25/25
1003
162
216
27,0
1550
973
3x35/35
1402
208
305
29,5
2100
1187
S 3x50/50
2000
288
435
29,0
2350
1194
S 3x70/75
2796
399
609
32,5
3190
1550
PP40-A
S 3x95/95
3791
554
827
37,5
4300
2088
S 3x120/120
4786
721
1044
40,5
5300
2528
S 3x150/150
5970
818
1305
43,5
6450
3008
S 3x185/185
7363
1069
1610
49,0
7939
3798
4x4/4
200
27
46
18,0
480
357
4x6/6
297
47
70
19,0
590
434
4x10/10
504
62
116
21,0
856
552
4x16//16
796
102
186
23,5
1192
728
1142
102
290
30,0
1802
1052
4x25 /16 *
4x35 /16
1526
102
406
31,5
2175
1258
S 4x50/25
2203
157
580
33,0
2640
1295
S 4x70/35
3082
208
812
35,0
3574
1699
S 4x95/50
4208
289
1102
40,5
4834
2229
S 4x120/70
5388
420
1392
44,5
5938
2717
S 4x150/70
6540
420
1740
48,0
7296
3318
S 4x185/95
8044
593
2148
53,5
9133
4086
10330
773
2784
61,0
11865
5296
S 4x240/ 120
It is possible to produce construction sector shape according to customer requirement.
1)
[kg/km]
5100
*
006
Cu number
PP40
S 3x150/70
*
*
Cu number
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 12D (D – cable diameter).
PP 41, PP 41-A
ВБбШв, АВБбШв; NYBY, NAYBY
Power cables with mechanical protection Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type PP 41, or aluminium: type PP 41-A. Insulation: PVC compound. Core: two or multi cores are stranded together. Fillig: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped two steel tapes. Sheath: PVC compound. Sheat colour black.
For laying in earth, indoors, in ducts, in the open air in urban networks, industrial plants and electrical power plants, when mechanical damage could be expected, due to rodents and hand tools. Laying in sloping grounds is not allowed, nor cable hanging.
APPLICATION
CONSTRUCTION DATA Construction1)
Cu number
Al number
PP41
PP41-A
[kg/km]
[kg/km]
Diameter
Mass
[kg/km]
[mm]
PP41
2x1,5
29
-
13,0
263
-
2x2,5
48
-
14,0
309
-
2x4
77
23
15,5
390
545
2x6
115
36
16,5
461
610
2x10
192
58
18,5
595
719
2x16
307
93
20,5
784
859
2x25
480
145
24,5
1141
1208
43
-
13,5
292
-
3x1,5 3x2,5
PP41-A
72
-
14,5
350
-
3x4
115
35
16,5
445
585
3x6
173
52
17,5
539
658
3x10
288
87
19,0
709
781
3x16
461
139
22,5
1004
939
3x25*
720
218
27,5
1789
1326
3x35*
1008
305
30,0
2203
1556
S 3x50
1440
435
30,0
2318
1418
S 3x70
2016
609
32,5
3021
1725
S 3x95
2736
827
36,5
3955
2190
007
Construction1)
PP41-A
Diameter
Mass
[kg/km]
[kg/km]
[kg/km]
[mm]
PP41
PP41-A
3456
1044
39,5
4813
2517
S 3x150
4320
1305
43,5
5783
2984
S 3x185
5328
1610
48,0
7139
3609
S 3x240
6912
2088
53,5
9069
4393
3x25+16*
874
263
29,5
2038
1128
*
3x35+16
1162
351
30,0
2193
1171
S 3x50+25
1680
507
34,0
2792
1707
S 3x70+35
2352
711
35,0
3452
2071
S 3x95+50
3216
972
40,5
4635
2628
S 3x120+70
4128
1247
42,5
5556
3985
S 3x150+70
4992
1508
46,5
6602
3659
S 3x185+95
6240
1888
50,0
8135
4291
S 3x240 +120
8064
2436
58,0
10626
5671
4x1,5
58
-
14,5
321
-
4x2,5
96
-
15,5
398
-
4x4
154
46
17,5
520
649
4x6
230
70
18,5
631
733
4x10
384
116
20,5
852
880
4x16
614
186
24,0
1219
1093
960
290
28,0
1723
1517
4x25
*
*
Al number
PP41
S 3x120
*
08
Cu number
4x35
1344
406
32,5
2656
1785
S 4x50
1920
580
32,0
2649
1372
S 4x70
2688
812
38,0
3910
2131
S 4x95
3648
1102
41,5
5059
2568
S 4x120
4608
1392
45,5
6125
3075
S 4x150
5760
1740
51,0
7601
3769
S 4x185
7104
2148
54,5
9111
4457
S 4x240
9216
3480
60,0
11793
5558
5x1,5
72
-
15,0
367
-
5x2,5
120
-
16,5
460
-
5x4
192
58
18,5
607
731
5x6
288
88
20,0
746
832
5x10
480
145
22,5
1015
1030
5x16
768
233
28,0
1833
1275
5x25
1200
363
31,0
2095
1796
It is possible to produce construction sector shape according to customer requirement.
1)
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 12D (D – cable diameter).
PP 44; PP 44-A
NYRGY, NAYRGY
Power cables with mechanical protection Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type PP 44, or aluminium: type PP 44-A. Insulation: PVC compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped zinc-plated round steel wire with or without contra helical zinc-plated steel tape (obligatory when cable is used in mines). Sheath: PVC compound. Sheat colour black.
For laynig in earth, indoors, in ducts, in the open air, in the water, when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines according to Technical standards for electrical plants, equipments and installations in mines, as well as horizontal and vertical installation in places where there is a height difference in mines, including methane holes.
APPLICATION
009 CONSTRUCTION DATA Construction1)
Cu number
Al number
PP44
PP44-A
[kg/km]
[kg/km]
Diameter [mm]
Mass PP44
[kg/km] PP44-A
3x6
183
52
18,5
775
560
3x10
288
67
21,0
1034
680
3x16
461
139
24,0
1408
1120
720
218
28,0
1871
1470
*
3x25
*
3x35
1008
305
30,0
2204
1980
S 3x50
1440
435
31,0
2760
1870
S 3x70
2016
609
35,0
3760
2470
S 3x95
2736
827
39,0
4519
3020
S 3x120
3456
1044
42,0
5710
3420
S 3x150
4320
1305
47,0
7240
4440
S 3x185
5328
1610
52,0
8700
5170
S 3x240
6912
2088
58,0
10950
6270
Construction1)
010
Al number
PP44
PP44-A
Diameter
Mass
[kg/km]
[kg/km]
[kg/km]
[mm]
3x25+16*
874
263
29,0
2100
1520
*
3x35+16
1162
351
31,0
2482
1760
S 3x50+25
1680
507
35,0
3550
2490
S 3x70+35
2352
711
36,5
4062
2940
S 3x95+50
3216
972
41,0
5184
2950
S 3x120+70
4128
1247
43,5
6222
4650
S 3X150+70
4992
1508
53,0
8580
5350
S 3X185+95
6240
1886
53,5
9308
6100
S 3X240+120
8064
2436
64,0
12636
7209
4x6
230
70
20,0
758
640
4x10
384
116
21,5
973
780
4x16
PP44
614
186
26,5
1576
1270
960
290
31,0
2251
1628
4x35*
1344
406
36,0
3440
2540
S 4x50
1920
580
34,5
3349
2510
S 4x70
2688
812
38,5
4320
2580
S 4x95
3648
1102
43,0
5637
3680
S 4x120
4608
1392
47,0
7137
4730
S 4x150
5760
1740
51,5
8566
4827
S 4x185
7104
2148
56,5
10345
6250
S 4x240
9216
2784
64,0
13642
7770
5x6
288
88
22,0
1040
725
5x10
480
145
25,0
1276
1200
5x16
768
-
30,0
2190
-
5x25
1200
-
33,0
2547
-
It is possible to produce construction sector shape according to customer requirement.
1)
PP44-A
*
4x25
*
Cu number
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 12D (D – cable diameter).
PP 45; PP 45-A
NYFGY, NAYFGY
Power cables with mechanical protection Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type PP 45, or aluminium: type PP 45-A. Insulation: PVC compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: lapped zinc-plated flat steel wire with contra helical zinc-plated steel tape. Sheath: PVC compound. Sheath colour black.
For laying in earth, indoors, in ducts, in the open air, in the water, when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines according to Technical standards for electrical plants, equipments and installations in mines, as well as horizontal and vertical installation in places where there is a height difference in mines, including methane holes.
APPLICATION
011 CONSTRUCTION DATA Construction1)
Cu number
Al number
PP45
PP45-A
Diameter
Mass [kg/km]
[kg/km]
[kg/km]
[mm]
*
720
218
27,0
1820
1200
*
3x35
1008
305
30,0
2350
1660
S 3x50
1440
435
29,0
2450
1550
S 3x70
2016
609
32,0
3150
1850
S 3x95
2736
827
37,0
4150
2350
S 3x120
3456
1044
40,0
4980
2680
S 3x150
4320
1305
43,0
5950
3160
S 3x185
5328
1610
48,0
7350
3860
S 3x240
6912
2088
53,0
9350
4650
*
874
263
29,0
2190
1600
*
3x35+16
1162
351
30,5
2394
1870
S 3x50+25
1680
507
33,0
2932
1890
3x25
3x25+16
PP45
PP45-A
Construction1)
*
Cu number
Al number
PP45
PP45-A
Mass [kg/km]
[kg/km]
[kg/km]
[mm]
S 3x70+35
2352
711
37,0
PP45 3780
2265
S 3x95+50
3216
972
39,0
4657
2544
S 3x120+70
4128
1247
45,0
6050
3315
S 3X150+70
4992
1508
50,0
7240
4000
S 3X185+95
6240
1886
53,0
8750
4620
S 3X240+120
8064
2436
60,5
11058
5880
4x6
230
70
20,0
809
659
4x10
384
116
22,0
1064
813
4x16
614
186
23,0
1563
1050
4x25*
960
290
29,0
2090
1500
*
4x35
1344
406
33,0
2800
1900
S 4x50
1920
580
33,0
3110
1900
S 4x70
2688
812
36,5
3994
2310
S 4x95
3648
1102
42,0
5330
2900
S 4x120
4608
1392
44,5
6159
3400
S 4x150
5760
1740
50,0
7850
4150
S 4x185
7104
2148
53,0
9510
4810
S 4x240
9216
2784
61,0
12300
6090
5x6
288
88
21,0
942
754
5x10
480
145
23,5
1245
932
5x16
768
233
26,5
1740
1192
5x25
1200
363
32,0
2438
1684
It is possible to produce construction sector shape according to customer requirement.
1)
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C.
012
Diameter
Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 12D (D – cable diameter).
PP45-A
XP 00, XP 00-A
N2XY, NA2XY
Power cables with XLPE insulation Standard: SRPS N.C5.230 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type XP 00, or aluminium: type XP 00-A. Insulation: XLPE compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Cables with sector shaped conductors (designated S in the table) wrapped thermoplastic tapes. Sheath: PVC compound. Sheath colour black.
For laying indoors, in ducts, in earth, in the open air, in urban networks and industrial plants, electric power plants and switchgear assemblies, where one cannot expect mechanical damages.
APPLICATION
CONSTUCTION DATA Construction1) 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 3x1,5 3x2,5
Cu number
Al number
XP00
XP00-A
[kg/km] 14,4 24 38 58 96 154 240 336 480 672 912 1152 1440 1778 2304 29 48 77 115 192 307 480 43 72
[kg/km] 12 18 29 46 72 102 145 203 276 348 435 537 696 23 36 58 93 145 -
Diameter [mm] 6,5 7,0 7,5 8,5 9,5 10,5 12,0 13,0 14,5 17,0 18,5 19,5 22,0 24,0 27,0 10,0 10,5 12,0 13,5 15,5 17,5 21,0 10,5 12,0
Mass XP00 46 59 77 109 169 221 324 425 579 788 1044 1277 1605 1938 2501 129 164 218 291 420 586 886 148 202
[kg/km] XP00-A 52 63 90 116 171 208 266 344 437 533 642 785 1009 168 246 296 388 571 -
013
Construction
S S S S S S S
S S S S S S S
014
S S S S S S S
1)
3x4 3x6 3x10 3x16 3x25* 3x35* 3x50 3x70 3x95 3x120 3x150 3x185 3x240 3x25+16* 3x35+16* 3x50+25 3x70+35 3x95+50 3x120+70 3x150+70 3x185+95 3x240 +120 4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25* 4x35* 4x50 4x70 4x95 4x120 4x150 4x185 4x240 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25
Cu number
Al number
XP00
XP00-A
[kg/km] 115 173 288 461 720 1008 1440 2016 2736 3456 4320 5328 6912 874 1162 1680 2352 3216 4128 4992 6240 8064 58 96 154 230 384 614 960 1344 1920 2688 3648 4608 5760 7104 9216 72 120 192 288 480 768 1200
[kg/km] 35 52 87 139 218 305 435 609 827 1044 1305 1610 2088 263 351 507 711 972 1247 1508 1888 2436 46 70 116 186 290 406 580 812 1102 1392 1740 2148 3480 58 88 145 233 363
Diameter [mm] 12,5 13,5 15,5 18,5 22,0 24,5 23,5 27,5 30,5 33,5 37,5 41,5 47,5 23,0 26,0 27,5 30,5 34,5 38,5 44,0 49,5 53,0 11,0 12,0 13,5 14,5 16,5 20,0 24,0 26,0 27,0 31,5 35,5 39,5 43,5 49,0 54,5 12,0 13,0 14,5 16,5 18,0 21,5 27,0
Mass XP00 258 333 490 731 1099 1445 1579 2223 3000 3750 4623 5747 7557 1268 1619 1963 2621 3511 4482 5564 7093 8947 172 226 301 404 577 853 1331 1770 2146 2977 3947 4976 6178 7666 9829 203 269 360 488 701 1087 1726
[kg/km] XP00-A 184 236 329 433 639 794 679 933 1195 1463 1834 2229 2897 692 864 807 1143 1443 1813 2078 2844 3528 210 313 383 497 752 966 886 1214 1566 1915 2329 3236 4369 240 324 457 583 953
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: - single core cables 15D; - multi core cables 12D (D – cable diameter).
XP 41, XP 41-A
ПвБбШв, АПвБбШв N2XBY, NA2XBY
Power cables with XLPE insulation and mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type XP 41, or aluminium: type XP 41-A. Insulation: XLPE compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped two steel tapes. Sheath: PVC compound. Sheath colour black.
For laying in earth, indoors, in ducts, in the open air in urban networks, industrial plants and electric power plants, when mechanical damage could be expected, due to rodents and hand tools. Laying on sloping grounds is not allowed, nor cable hanging.
APPLICATION
CONSTRUCTION DATA Construction 2x1,5
1)
Cu number
Al number
XP41
XP41-A
[kg/km]
[kg/km]
29
Diameter [mm]
-
14,5
Mass XP41 387
[kg/km] XP41-A -
2x2,5
48
-
15,0
441
-
2x4
77
23
16,0
512
462
2x6
115
36
17,0
596
521
2x10
192
58
19,0
748
623
2x16
307
93
21,5
997
754
2x25
480
145
24,5
1256
1051
3x1,5
43
-
15,0
416
-
3x2,5
72
-
15,5
479
-
3x4
115
35
16,0
473
489
3x6
173
52
18,0
672
560
3x10
288
87
19,0
754
663
3x16
461
139
22,5
1165
818
720
218
26,0
1631
1167
*
3x25
*
3x35
1008
305
28,5
2034
1382
S 3x50
1440
435
28,0
2118
1218
015
Construction1)
XP41-A
Diameter
Mass
[kg/km]
[kg/km]
[kg/km]
[mm]
2016
609
31,5
2826
1530
S 3x95
2736
827
34,5
3672
1859
S 3x120
3456
1044
38,0
4519
2224
S 3x150
4320
1305
41,5
5445
2646
S 3x185
5328
1610
46,5
6739
3209
6912
2088
51,0
8560
3814
874
263
27,5
1818
1242
*
3x25+16
*
XP41
3x35+16
1162
351
29,5
2207
1444
1680
507
30,5
2487
1426
S 3x70+35
2352
711
34,5
3313
1796
S 3x95+50
3216
972
40,0
4580
2213
S 3x120+70
4128
1247
44,0
5649
2625
S 3x150+70
4992
1508
46,5
6641
3196
S 3x185+95
6240
1888
53,5
8237
3787
S 3x240 +120
8064
2436
57,5
10185
4522
58
-
15,5
458
-
4x2,5
96
-
16,5
536
-
4x4
154
46
17,5
639
539
4x6
230
70
19,0
765
616
4x10
384
116
20,5
888
752
4x16
614
186
23,5
1231
830
4x25*
960
290
26,5
1613
972
4x35*
1344
406
31,0
2450
1563
S 4x50
1920
580
30,5
2665
1465
S 4x70
2688
812
34,0
3596
1869
S 4x95
3648
1102
38,5
4623
2255
S 4x120
4608
1392
42,0
5749
2726
S 4x150
5760
1740
46,0
7001
3263
S 4x185
7104
2148
51,5
8493
3882
S 4x240
9216
3480
57,5
10818
4964
5x1,5
72
-
16,0
425
-
5x2,5
120
-
17,5
602
-
5x4
192
58
18,5
621
600
5x6
288
88
20,0
769
692
5x10
480
145
22,0
1050
860
5x16
768
233
26,0
1495
1098
5x25
1200
363
30,0
2139
1567
It is possible to produce construction sector shape according to customer requirement.
1)
XP41-A
S 3x50+25
4x1,5
*
Al number
XP41
S 3x70
S 3x240
016
Cu number
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C.
Smallest bending radius: 12D (D – cable diameter).
XP 44; XP 44-A
N2XRGY, NA2XRGY
Power cables with mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type XP 44, or aluminium: type XP 44-A. Insulation: XLPE compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped zinc-plated round steel wire with or without contra helical zinc plated steel tape (obligatory when cable is used in mines). Sheath: PVC compound. Sheath colour black.
For laying in earth, indoors, in ducts, in the open air, in the water, when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines according to Technical standards for electrical plants, equipments and installations in mines, as well as horizontal and vertical installation in places where there is a height difference in mines, including methane holes.
APPLICATION
017 CONSTRUCTION DATA Construction 3x6
1)
Cu number
Al number
XP44
XP44-A
[kg/km]
[kg/km]
183
52
Diameter [mm] 17,0
Mass XP44 612
[kg/km] XP44-A 500
3x10
288
67
19,0
800
611
3x16
461
139
22,5
1242
751
3x25*
720
218
27,0
1872
1400
*
3x35
1008
305
30,0
2290
1651
S 3x50
1440
435
30,0
2507
1607
S 3x70
2016
609
34,0
3384
2187
S 3x95
2736
827
37,5
4420
2608
S 3x120
3456
1044
40,5
5298
3000
S 3x150
4320
1305
44,0
6298
3500
S 3x185
5328
1610
50,0
8103
4573
S 3x240
6912
2088
55,0
10057
5380
Construction1)
018
Al number
XP44
XP44-A
[kg/km]
[kg/km]
Diameter [mm]
Mass
[kg/km]
XP44
874
263
28,0
1933
1497
*
3x35+16
1162
351
29,5
2284
1720
S 3x50+25
1680
507
32,5
2897
1838
S 3x70+35
2352
711
37,5
4060
2543
S 3x95+50
3216
972
41,0
5122
3011
S 3x120+70
4128
1247
44,0
6206
3478
S 3X150+70
4992
1508
50,5
7787
4540
S 3X185+95
6240
1886
54,5
9419
5286
S 3X240+120
8064
2436
61,5
11882
6444
4x6
230
70
14,5
701
557
4x10
384
116
16,5
929
685
4x16
614
186
24,5
1472
1140
*
960
290
28,5
2037
1593
4x35*
1344
406
30,0
2490
1876
S 4x50
1920
580
34,0
3574
1879
S 4x70
2688
812
37,5
4345
2608
S 4x95
3648
1102
41,0
5813
3101
S 4x120
4608
1392
44,0
6661
3585
S 4x150
5760
1740
50,0
8411
4715
S 4x185
7104
2148
54,5
10202
5471
S 4x240
9216
2784
62,0
12952
6686
5x6
288
88
19,5
822
886
5x10
480
145
21,5
1087
1070
5x16
768
-
27,0
1911
1333
5x25
1200
-
31,5
2639
1858
It is possible to produce construction sector shape according to customer requirement.
1)
XP44-A
3x25+16*
4x25
*
Cu number
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C.
Smallest bending radius: 12D (D – cable diameter).
XP 45, XP 45-A
N2XFGY, NA2XFGY
Power cables with mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: wire or rope, class 1 or 2, according to SRPS N.C0.015, copper: type XP 45, or aluminium: type XP 45-A. Insulation: XLPE compound. Core: two or multi cores are stranded together. Filling: non hygroscopic, non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped zinc-plated flat steel wire with contra helical zinc-plated steel tape. Sheath: PVC compound. Sheath colour black.
For laying in earth, indoors, in ducts, in the open air, in the water, when additional mechanical protection is required when cable is exposed to mechanical tensile strain during laying and use. For use in mines according to Technical standards for electrical plants, equipments and installations in mines, as well as horizontal and vertical installation in places where there is a height difference in mines, including methane holes.
APPLICATION
CONSTRUCTION DATA Construction1)
019
Cu number
Al number
XP45
XP45-A
Diameter
Mass
[kg/km]
[kg/km]
[kg/km]
[mm]
XP45
XP45-A
3x25*
720
218
25,5
1617
1149
*
3x35
1008
305
28,0
2010
1354
S 3x50
1440
435
28,0
2210
1309
S 3x70
2016
609
31,5
2925
1628
S 3x95
2736
827
35,0
3835
2023
S 3x120
3456
1044
38,0
4662
2367
S 3x150
4320
1305
42,0
5586
2787
S 3x185
5328
1610
46,5
6900
3372
S 3x240
6912
2088
51,5
8732
4057
3x25+16*
874
263
26,5
1807
1230
*
3x35+16
1162
351
29,0
2193
1426
S 3x50+25
1680
507
31,0
2593
1534
S 3x70+35
2352
711
35,5
3476
1958
S 3x95+50
3216
972
38,5
4461
2350
Construction1)
Al number
XP45
XP45-A
Diameter
[kg/km]
[kg/km]
[kg/km]
[mm]
XP45
XP45-A
4128
1247
42,0
5494
2766
S 3X150+70
4992
1508
47,0
6586
3339
S 3X185+95
6240
1886
51,0
8095
3962
S 3X240+120
8064
2436
58,0
10400
4964
4x6
230
70
18,0
753
603
4x10
384
116
20,0
1006
755
4x16
614
186
23,5
1374
910
*
960
290
28,0
1946
1319
4x35*
1344
406
30,5
2447
1572
S 4x50
1920
580
31,0
2780
1574
S 4x70
2688
812
35,0
3729
1992
S 4x95
3648
1102
38,5
4870
2440
S 4x120
4608
1392
41,5
5949
2873
S 4x150
5760
1740
47,0
7264
3513
S 4x185
7104
2148
51,0
8878
4147
S 4x240
9216
2784
58,0
11436
5170
5x6
288
88
19,5
837
686
5x10
480
145
21,5
1170
857
5x16
768
233
25,5
1628
1057
5x25
1200
363
30,0
2325
1570
It is possible to produce construction sector shape according to customer requirement.
1)
S in front of the wire number means sector shape conductor.
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C.
020
Mass
S 3x120+70
4x25
*
Cu number
Smallest bending radius: 12D (D – cable diameter).
PHP 48, PHP 48-A
ВВГЭ, АВВГЭ, NYSY, NAYSY
Medium voltage cables with PVC insulation Standard: SRPS N.C5.220 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core copper (PHP 48) or aluminium (PHP 48-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: special high-voltage PVC compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Sheath: PVC compound. Sheath colour black, for use in mine red.
Suitable for laying down in closely rooms, for power plants, transformers, industrial plants, etc. Suitable for laying down into lessaccessible localities, because of its little weight.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
PHP 48 Cu number Diameter [kg/km] [mm]
PHP 48-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
1x25/16
360
23,0
896
72
182
23,0
742
1x35/16
456
24,0
1023
102
182
24,5
808
1x50/16
622
26,0
1204
145
182
26,0
913
1x70/16
854
27,5
1456
203
182
27,5
1031
1x95/16
1094
29,5
1764
276
182
29,5
1176
1x120/16
1334
31,0
2039
348
182
29,5
1056
1x150/25
1723
32,0
2448
435
283
31,0
1226
1x185/25
2059
34,0
2833
537
283
32,5
1371
1x240/25
2587
36,0
3324
696
283
37,0
1966
1x300/25
3163
38,5
3990
870
283
39,5
2225
n – number of the wires, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
021
PHP 48, PHP 48-A
ВВГЭ, АВВГЭ, NYSEY, NAYSEY
Medium voltage cables with PVC insulation Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core copper (PHP 48) or aluminium (PHP 48-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: special high-voltage PVC compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Filling: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Outer sheath: PVC compound. Sheath colour black, for use in mine red.
Indoors, in ducts, in earth, in the open air in distributive lattice, industrial plants and power plants. Laying down, directly into the earth, is restricted by mechanical properties of PVC sheath.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
022
PHP 48 Cu number Diameter [kg/km] [mm]
PHP 48-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
3x25/16
921
42,5
2769
218
231
42,5
2303
3x35/16
1209
47,5
3764
305
231
48,0
3123
3x50/16
1671
48,5
3909
435
231
48,5
2964
3x70/16
2247
54,0
4737
609
231
54,0
3389
3x95/16
2994
57,0
5747
827
258
56,0
4037
3x120/16
3714
58,0
6958
1044
258
61,0
4495
3x150/25
4603
63,0
8240
1305
315
65,0
5250
3x185/25
5611
66,5
9405
1610
315
66,5
5890
3x240/25
7272
75,5
12259
2088
362
76,0
7689
3x300/25
9160
78,5
13478
2610
520
78,5
7842
n – number of the wires, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
PHP 81, PHP 81-A
NYSEYBY, NAYSEYBY
Medium voltage cables with PVC insulation Standard: SRPS N.C5.220 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core copper (PHP 81) or aluminium (PHP 81-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: special high-voltage PVC compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Armour: wrapped two steel tapes. Sheath: PVC compound. Sheath colour black, for use in mine red.
In urban networks, industrial plants and electric power plants, when the cable is exposed to mechanical damages. Indoors, in the open air, in ducts, in earth when mechanical protection is required.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
PHP 81 Cu number Diameter [kg/km] [mm]
PHP 81-A Mass [kg/km]
Al number [kg/km]
Cu number [kg/km]
Diameter [mm]
Mass [kg/km]
3x25/16
921
46,0
3715
218
231
46,0
3261
3x35/16
1209
50,0
4377
305
231
50,0
3740
3x50/16
1671
50,5
4754
435
231
52,5
4134
3x70/16
2247
56,0
5756
609
231
56,0
4717
3x95/16
2994
59,0
6932
827
258
59,0
5129
3x120/16
3714
64,0
8391
1044
258
62,0
5681
3x150/25
4603
67.5
9627
1305
315
68,0
6865
3x185/25
5611
72,0
11216
1610
315
73,0
7841
3x240/25
7272
77,5
13572
2088
362
78,0
9010
3x300/25
9160
82,5
15783
2610
520
84,0
10375
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
023
PHP 84, PHP 84-A
NYSEYRGY, NAYSEYRGY
Medium voltage cables with PVC insulation Standard: SRPS N.C5.220 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core annealed copper (PHP 84) or aluminium (PHP 84-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: special high-voltage PVC compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer. Armour: wrapped round zinc-plated steel wires with or without contra helical zinc-plated steel tape. Outer sheath: PVC compound. Sheath colour black, for use in mining red.
In urban networks, industrial plants and electric power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth. Suitable for cable lifting in mines.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
024
PHP 84 Cu number [kg/km]
Diameter
[mm]
PHP 84-A Mass [kg/km]
Al number [kg/km]
Cu number [kg/km]
Diameter
[mm]
Mass [kg/km]
3x25/16
921
50,5
5199
218
231
51,0
4743
3x35/16
1209
53,5
5854
305
231
53,5
5212
3x50/16
1671
55,0
5935
435
231
54,0
5020
3x70/16
2247
60,5
7772
609
231
60,5
6497
3x95/16
2994
62,5
8717
827
258
65,0
7400
3x120/16
3714
68,0
10281
1044
258
66,5
7351
3x150/25
4603
72,0
11767
1305
315
72,5
9034
3x185/25
5611
75,5
13330
1610
315
76,5
9979
3x240/25
7272
83,5
16961
2088
362
51,0
4743
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
PHP 85, PHP 85-A
NYSEYFGY, NAYSEYFGY
Medium voltage cables with PVC insulation Standard: SRPS N.C5.220 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core annealed copper (PHP 85) or aluminium (PHP 85-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: special high-voltage PVC compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer. Armour: wrapped flat zinc-plated steel wires with contra helical zinc plated steel tape. Outer sheath: PVC compound. Sheath colour black, for use in mine red.
In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For lying in ducts, in the open air and in earth.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
PHP 85 Cu number Diameter [kg/km] [mm]
PHP 85-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
3x25/16
921
46,5
3891
218
231
46,5
3434
3x35/16
1209
50,0
4541
305
231
50,0
3925
3x50/16
1671
52,5
5183
435
231
52,5
4308
3x70/16
2247
56,0
6193
609
231
56,5
4918
3x95/16
2994
59,0
7145
827
258
59,0
5342
3x120/16
3714
64,5
8620
1044
258
64,5
6498
3x150/25
4603
65,5
9569
1305
315
65,5
6700
3x185/25
5611
72,0
11473
1610
315
73,5
8108
3x240/25
7272
78,0
13853
2088
362
78,0
9285
3x300/25
9210
83,5
16459
2610
362
84,0
10682
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
025
XHP 48, XHP 48-A
N2XSY, NA2XSY
Medium voltage cables with XLPE insulation Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV, Test voltage: 15 kV,
12/20 kV, 30 kV,
20/35 kV 50 kV
CONSTRUCTION Conductor: multi-core copper (XHP 48) or aluminium (XHP 48-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: XLPE compound. Outer semi-conductive layer: extruded. Wrapped semiconductive tape over extruded layer, used as bedding for electric protection. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Sheath: PVC compound. Sheath colour black, for use in mining red.
For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants, when additional mechanical damages are not expected.
APPLICATION CONSTRUCTION DATA nxq/q1 [mm2]
XHP 48 Cu number Diameter [kg/km] [mm]
XHP 48-A Mass
[kg/km]
Al number [kg/km]
Cu number [kg/km]
Diameter [mm]
Mass
145 203 276 348 435 537 696 870
182 182 182 182 283 283 283 283
26,0 28,0 29,5 31,0 32,5 34,0 35,5 39,0
695 821 931 1030 1239 1412 1611 1894
145 203 276 348 435 537 696 870
182 182 182 182 283 283 283 283
30,5 32,5 33,0 35,0 37,0 39,0 41,5 43,0
913 994 1148 1222 1467 1665 1917 2055
145 203 276 348 435 537 696 870
182 182 182 182 283 283 283 283
37,5 39,0 40,0 42,0 43,0 44,5 48,0 50,5
1298 1443 1580 1706 1932 2104 2469 2675
[kg/km]
6/10 kV
026
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
26,0 28,0 29,5 31,0 32,5 34,0 35,5 39,0
1010 1266 1535 1792 2210 2534 3136 3851
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
30,5 32,5 33,0 35,0 37,0 39,0 41,5 43,0
1238 1458 1731 1984 2414 2854 3478 4028
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
37,5 39,0 40,0 42,0 43,0 44,5 48,0 50,5
1598 1877 2175 2453 2879 3240 3993 4602
12/20 kV
20/35 kV
n – number of the wires, q – nominal cross section of the conductor, q1 – cross section of the electrical protection
XHP 48, XHP 48-A
N2XSEY, NA2XSEY
Medium voltage power cables with XLPE insulation Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core copper (XHP 48) or aluminium (XHP 48-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: XLPE compound. Outer semi-conductive layer: extruded. Wrapped semiconductive tape over extruded layer, used as bedding for electrical protection. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Filling: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Outer sheath: PVC compound. Sheath colour black, for use in mining red.
APPLICATION
For laying indoors, in ducts, directly in earth, in the open air in distribution networks, industrial plants and electric power plants. Laying down directly in the earth is limited by the mechanical properties of the PVC sheath.
CONSRUCTION DATA nxq/q1 [mm2]
XHP 48 Cu number Diameter [kg/km] [mm]
XHP 48-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
6/10 kV 3x50/16
1671
51,5
3714
435
231
51,5
2751
3x70/16
2247
55,5
4583
609
231
55,5
3236
3x95/16
2994
60,0
5703
827
258
60,0
3873
3x120/16
3714
62,5
6617
1044
258
62,5
4306
3x150/25
4603
68,0
7989
1305
315
68,0
5039
3x185/25
5611
69,5
9051
1610
315
69,5
5489
3x240/25
7272
76,5
11318
2088
362
76,5
6696
3x300/25
9160
80,0
13632
2610
520
80,0
7793
n – number of the wires, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
027
XHE 49, XHE 49-A
N2XS(F)2Y, NA2XS(F)2Y
Medium voltage cables with XLPE insulation and longitudinally protection from moisture Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV, Ispitni napon: 15 kV,
12/20 kV, 30 kV,
20/35 kV 50 kV
CONSTRUCTION Conductor: multi-core compacted copper (XHP49) or aluminium (XHP 49-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer: extruded. Insulation: XLPE compound. Outer semi-conductive layer: extruded. Inner sealing layer: wrapped semi-conductive waterproof tape, used as bedding for electrical protection as well as additional protection of the insulation from water penetration along the screen. Electrical protection: wrapped annealed copper wires with contra-helical annealed copper tape or wrapped copper tape. Layer: wrapped waterproof tape. Sheath: special PE compound. Sheath colour black.
In distributing network mains, industrial plants, middle-voltage and high voltage switchgear assemblies, thermo-power plants and electric power plants, when cables are exposed to aggressive and wet surrounding effects. For laying indoors, in ducts, in the open air, on cable trays, in earth and in the water.
APPLICATION
CONSTRUCTION DATA nxq/q1 [mm2]
028
XHE 49 Cu number Diameter [kg/km] [mm]
XHE 49-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
6/10 kV 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
1094 1334 1723 2059 2587 3163
31,0 32,0 32,5 34,5 37,5 41,5
1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
1094 1334 1723 2059 2587 3163
34.5 36,0 38,0 41,5 42,0 45,0
1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
1094 1334 1723 2059 2587 3163
42,5 44,0 45,0 48,5 52,5 49,0
1490 1701 2136 2468 3058 3700
276 348 435 537 696 870 12/20 kV 1700 276 2036 348 2270 435 2695 537 3280 696 3960 870 20/35 kV 2051 276 2310 348 2742 435 3185 537 3865 696 4280 870
182 182 283 283 283 283
31,0 32,0 32,5 34,5 37,5 41,5
885 1005 1162 1293 1533 1797
182 182 283 283 283 283
34,5 36,0 38,0 41,5 42,0 45,0
1090 1242 1379 1610 1754 2043
182 182 283 283 283 283
42,5 44,0 45,0 48,5 52,5 49,0
1465 1508 1768 1985 2306 2569
n – number of the wires, q – nominal cross section of the conductor, q1 – cross section of the electrical protection
XHEh 91, XHEh 91-A Medium voltage cables with XLPE insulation and additional electrical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV, Test voltage: 15 kV,
12/20 kV, 30 kV,
20/35 kV 50 kV
K CONSTRUCTION KO ON NS ST TR RU UK KC CIIJJA A Conductor: multi-core copper (XHEh 91) or aluminium (XHEh 91-A) compacted conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer: extruded. Insulation: XLPE compound. Outer semi-conductive layer: extruded. Inner sealing layer: wrapped semi-conductive, waterproof tape, used as bedding for electric protection as well as additional protection to the insulation from the break along the screen. Electric protection: wrapped annealed copper wires with contra-helical annealed copper tape or wrapped copper tape. Sealing layer: wrapped semi-conductive, waterproof tape. Outer sheath: semi-conductive PE compound. Additional electric protection: wrapped tinned copper wires, as single-layer or double-layer: subject to cross-section needed.
APPLICATION
For laying in earth or on supports. The cable bears medium axial tensile strains. In medium-voltage distributing network mains, when the cable is laying in area with high ground conductivity, for protection of electric power plants from over-voltages caused by lightning or other failures at high-voltage transmission network.
Additional electric protection is rated in dependence on the request, i.e., exploit conditions. All other data are the same as for cable type XHE 49. The same is valid for electric features and permitted current ratings, as well as permitted short circuit current for phase conductor. Permitted short circuit current for electric protection of cable depends on cross-section of additional electric protection. Electric protection and additional protection must be joined each other, leastwise at cable clamps and cable heads. The data cable is provided to an individual user request.
029
XHP 81, XHP 81-A
N2XSYBY, NA2XSYBY N2XSEYBY, NA2XSEYBY
Medium voltage cables with XLPE insulation and mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core copper (XHP 81) or aluminium (XHP 81-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer: extruded. Insulation: XLPE compound. Outer semi-conductive layer: extruded, with wrapped semiconductive tape over extruded layer. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Armour: wrapped two steel tapes. Outer sheath: PVC compound. Sheath colour black, for use in mining red.
For laying indoors, in ducts, in the open air, directly in earth, in urbane networks, industrial plants and power plants. Suitable for the networks which require minor reduction factor. Not provided for complicated conditions in terms of severe axial strains.
APPLICATION
CONSTRUCTION DATA
030
nxq/q1 [mm2]
XHP 81
XHP 81-A
Cu number [kg/km]
Diameter [mm]
Mass [kg/km]
Al number Cu number [kg/km] [kg/km]
Diameter [mm]
Mass [kg/km]
3x50/16
1671
50,5
4554
435
231
55,5
4227
3x70/16
2247
55,5
5517
609
231
61,0
5046
3x95/16
2994
61,0
6862
827
258
63,0
5667
3x120/16
3714
63,0
7432
1044
258
66,5
6237
3x150/25
4603
66,5
8952
1305
315
70,0
7153
3x185/25
5611
70,0
10479
1610
315
75,5
8187
3x240/25
7272
75,5
12865
2088
362
83,5
9431
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
XHP 84, XHP 84-A
N2XSYRGY, NA2XSYRGY N2XSEYRGY, NA2XSEYRGY
Medium voltage cables with XLPE insulation and mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core annealed copper (XHP 84) or aluminium (XHP 84-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer Insulation: XLPE compound. Outer semi-conductive layer: extruded, strongly attached to insulation, with lapped semi-conductive tape over extruded layer used as bedding for electric protection. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Armour: wrapped round zinc-plated steel wires with or without contra-helical zinc-plated steel tape Outer sheath: PVC compound. Sheath colour black, for use in mining red.
In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth.
APPLICATION CONSTRUCTION DATA nxq/q1 [mm2]
XHP 84 Cu number Diameter [kg/km] [mm]
XHP 84-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
3x50/16
1671
53,5
5979
435
231
53,5
4771
3x70/16
2247
59,5
7259
609
231
59,5
5659
3x95/16
2994
61,5
8155
827
258
61,5
6281
3x120/16
3714
65,0
9494
1044
258
65,0
7550
3x150/25
4603
71,5
11327
1305
315
71,5
8469
3x185/25
5611
76,0
13476
1610
315
76,0
10136
3x240/25
7272
81,0
15870
2088
362
81,0
11360
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
031
XHP 85, XHP 85-A
N2XSYFGY, NA2XSYFGY N2XSEYFGY, NA2XSEYFGY
Medium voltage cables with XLPE insulation and mechanical protection Standard: SRPS N.C5.230 Nominal voltage U0/U: 6/10 kV Test voltage: 15 kV
CONSTRUCTION Conductor: multi-core annealed copper (XHP 85) or aluminium (XHP 85-A) conductor class 2, according to SRPS N.C0.015. Inner semi-conductive layer: extruded. Insulation: XLPE compound. Outer semi-conductive layer: extruded, with lapped semiconductive tape over extruded layer used as bedding for electric protection. Electric protection: wrapped annealed copper wires with contrahelical annealed copper tape or wrapped copper tape. Core: 3 cores are stranded together. Separate sheath: extruded, non hygroscopic layer over the core that completely fills the space between the cores. Armour: wrapped flat zinc-plated steel wires with contra-helical zinc-plated steel tape Outer sheath: PVC compound. Sheath colour black, for use in mining red.
In urban networks, industrial plants and power plants, when the cable is exposed to severe mechanical tensile strains during laying down or use. For laying in ducts, in the open air and in earth.
APPLICATION CONSTRUCTION DATA nxq/q1 [mm2]
032
XHP 85 Cu number Diameter [kg/km] [mm]
XHP 85-A Mass [kg/km]
Al number [kg/km]
Cu number Diameter [kg/km] [mm]
Mass [kg/km]
3x50/16
1671
51,5
4635
435
231
51,5
3878
3x70/16
2247
54,5
5536
609
231
54,5
4414
3x95/16
2994
60,0
6606
827
258
60,0
5272
3x120/16
3714
63,5
7450
1044
258
63,5
5892
3x150/25
4603
65,5
8852
1305
315
65,5
6471
3x185/25
5611
69,0
10257
1610
315
69,0
7277
3x240/25
7272
81,0
13870
2088
362
75,0
8439
3x300/25
9160
82,0
15491
2610
520
82,0
9722
n – number of the wire, q – nominal cross section of the conductor, q1 – cross section of the electrical protection Permissible conductor temperature: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
0033
POWER CONDUCTORS H07V-U, -R NYM PP-R PP-U H07V-K
035 036 037 038 039
H03VH-H H03VV-F H05VV-F PP-JZ H05VVH6-F
040 041 042 043 044
P
H07V-U, H07V-R
Installation cable with PVC Standard: SRPS N.C3.200 Nominal voltage U0/U: 450/750 V Test voltage: 2,5 kV
CONSTRUCTION Conductor: solid annealed copper conductor class 1 or multicore annealed copper conductor class 2, according to SRPS N.C0.015. Insulation: PVC compound. Insulation colour black, blue, brown, green/yellow.
For fixed electric power installations in dry conditions, drawn in tubes, on plaster or under the plaster, or laid on insulators over plaster.
APPLICATION
CONSTRUCTION DATA nxq [mm2]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
1,5
14.4
2,8
20
2,5
24
3,5
31
4
38
4,0
46
6
58
4,5
66
10
96
5,5
107
10
96
6,0
116
16
154
7,0
172
25
240
8,6
268
35
336
9,7
363
50
480
11,3
494
70
672
14,0
725
95
912
15,3
959
120
1152
16,2
1194
150
1440
18,2
1498
185
1776
22,3
1912
240
2304
25,0
2433
300
2880
27,9
3041
400
3840
31,6
3915
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 12D - 15 D (D – cable diameter).
035
PP
NYM
Installation cable with PVC Standard: SRPS N.C3.220 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper wire class 1 or strand class 2, according to SRPS N.C0.015. Insulation: PVC compound. Core: two or more cores are stranded together. Filling: non vulcanized rubber compound layer is over the core. Sheath: PVC compound. Sheath colour grey.
APPLICATION
In dry and wet conditions indoors and in the open air, for laying on plaster, in plaster or under plaster. Cable is suitable for installations in food industries, laundries and so on.
CONSTRUCTION DATA nxq [mm2]
036
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter [kg/km]
Mass
[mm]
[kg/km]
2x1,5
29
8,5
110
4x1,5
58
10,0
151
2x2,5
48
9,8
148
4x2,5
96
11,0
213
2x4
77
10,9
202
4x4
154
13,0
308
2x6
115
2,6
288
4x6
230
14,5
410
2x10
192
16,0
467
4x10
384
17,5
645
2x16
308
18,5
669
4x16
614
21,0
978
2x25
480
21,5
936
4x25
960
25,0
1496
2x35
672
24,5
1295
4x35
1344
27,5
1989
3x1,5
43
9,0
129
5x1,5
72
10,5
182
3x2,5
72
10,5
178
5x2,5
120
12,0
260
3x4
115
12,5
243
5x4
192
14,0
375
3x6
173
14,0
332
5x6
288
15,5
498
3x10
288
17,0
571
5x10
480
19,0
795
3x16
461
19,5
828
5x16
768
25,0
1233
3x25
720
26,0
1297
5x25
1200
28,0
1833
3x35
1008
29,5
1700
5x35
1680
35,5
2578
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius for permanently laid cable: 6D (D - cable diameter).
PP/R Installation cable with PVC Standard: SRPS N.C3.230 Nominal voltage: 380 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper wire class 1, according to SRPS N.C0.015. Insulation: PVC compound. Sheath: PVC compound layer over 2 or 3 cores, which are laid parallel. The layer is forming the track between the cores, with the notch in the middle of the track, this making possible temporary fixing of the cables. Sheath colour can be grey or black.
In dry conditions indoors, for laying in plaster or under plaster, without special mechanical protection. Suitable for installations in objects made of prestressed concrete, vibrated concrete or prefabricated elements, when the notches for laying the round cables can not be made. Not for use in wooden object, nor in open air.
APPLICATION
CONSTRUCTION DATA nxq
Cu number
Height x width
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
2x1,5
29
4,4x12,0
66
2x2,5
48
5,2x13,5
98
3x1,5
43
4,4x19,5
104
3x2,5
72
5,2x22,5
151
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 4a (a – cable height).
037
PP/U Flat installation cable with PVC Standard: SRPS N.C3.235 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper wire class 1 or strand class 2, according to SRPS N.C0.015. Insulation: PVC compound. Core: two or more cores are laid side by side. Sheath: PVC compound. Sheath colour grey.
APPLICATION
In dry and wet conditions indoors, for permanent laying on plaster, in plaster or under plaster, or on steel constructions.
CONSTRUCTION DATA nxq [mm2]
038
Cu number
Width x height
Mass
[kg/km]
[mm]
[kg/km]
nxq [mm2]
Cu number
Width x height
Mass
[kg/km]
[mm]
[kg/km]
2x1
19
8,2x5,6
57
3x1
29
11,4x6,2
85
2x1,5
29
8,8x5,9
68
3x1,5
43
12,3x6,5
105
2x2,5
48
10,0x6,5
112
3x2,5
72
14,1x7,1
185
2x4
77
12,2x7,9
145
3x4
115
16,7x8,1
217
2x6
115
13,2x8,4
191
3x6
173
18,2x8,6
286
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 4a (a – cable height).
P/F
H07V-K
Flexible installation cable with PVC Standard: SRPS N.C3.202 Nominal voltage U0/U: 450/750 V Test voltage: 2,5 kV
CONSTRUCTION Conductor: flexible strand or rope consists of annealed copper wires class 5, according to SRPS N.C0.015. Insulation: PVC compound. Insulation colour black, blue, brown, green/yellow.
APPLICATION
For usage in dry conditions where extra flexibility is require. Cable installs in tubes, over or under the plaster, or lay on insulators over plaster. Nominal cross-sections cable 0,5 mm2 and 0,75 mm2 are intended only for installations of equipments and distribution networks.
CONSTRUCTION DATA nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
0,5
4,8
2,2
9
25
240
9,3
272
0,75
7,2
2,3
12
35
336
11,1
372
1
9,6
2,5
14
50
480
13,4
532
1,5
14.4
3,1
20
70
672
15,3
759
2,5
24,0
3,8
33
95
912
18,3
1003
4
38,0
4,3
48
120
1152
19,2
1256
6
58,0
4,8
70
150
1440
20,3
1496
10
96,0
6,5
117
185
1776
22,7
1829
16
154
7,9
184
240
2304
26,6
2455
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 5 D (D – cable diameter).
039
P/L
H03VH-H
Flexible cable with PVC Standard: SRPS N.C3.300 Nominal voltage U0/U: 300/300 V Test voltage: 2 kV
CONSTRUCTION Conductor: flexible strand consists of annealed copper wires class 5, according to SRPS N.C0.015. Insulation: common PVC compound layer over two or three parallel laid conductors, which can be easily separated, without damaging the insulation. Sheath colour not defined all colours possible, transparent as well.
In dry rooms, for connecting of small mobile electric appliances, such as table lamps, wireless sets, table fans and so forth. It is advisable to protect the cable inlet place with a rubber or thermoplastic sleeve.
APPLICATION
CONSTRUCTION DATA nxq 2
[mm ]
040
Cu number
Height x width
Mass
[kg/km]
[mm]
[kg/km]
2x0,5
9,6
2.6x5,2
22
2x0,75
14,4
3,0x6,0
28
2x1
19.0
3,0x6,0
33
3x0,5
14,4
2,6x7,8
33
3x0,75
21,6
2,8x8,4
42
3x1
29.0
3,0x9,0
50
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 5a (a – cable height).
PP/L
H03VV-F
Flexible cable with PVC Standard: SRPS N.C3.301 Nominal voltage U0/U: 300/300 V Test voltage: 2 kV
CONSTRUCTION Conductor: flexible strand consists of annealed copper wires class 5, according to SRPS N.C0.015. Insulation: PVC compound. Core: 2 or 4 cores are stranded together. Sheath: PVC compound. Sheath colour can be white, grey or black.
In dry rooms, for connecting of small mobile electric appliances, such as table lamps, wireless sets, television sets, table fans and so forth, when the cord can be exposed to minor mechanical tensile strains.
APPLICATION
CONSTRUCTION DATA nxq 2
[mm ]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x0,5
9,6
5,5
35
2x0,75
14,4
5,7
44
2x1
19
6,0
52
3x0,5
14,4
5,5
43
3x0,75
21,6
6,0
53
3x1
29
6,5
64
4x0,5
19,2
6,0
54
4x0,75
29
6,7
66
4x1
38
6,9
78
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 5 D (D – cable diameter).
041
PP/J
H05VV-F
Flexible cable with PVC Standard: SRPS N.C3.302 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: flexible strand consists of annealed copper wires class 5, according to SRPS N.C0.015. Insulation: PVC compound. Core: 2 or 5 cores are stranded together. Sheath: PVC compound. Separation layer can be laid beneath the sheath. Sheath colour can be white, grey or black.
APPLICATION
For connecting of mobile electrical appliances under hard operational conditions, such as washing machines, vacuum cleaners. For connecting of thermal apparatus and domestic appliances if not in contact with heated surface over 85°C.
CONSTRUCTION DATA nxq [mm2]
042
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
2x0,75
15
6,4
55
4x0,75
29
7,4
78
2x1,0
19
6,8
63
4x1,0
38
7,9
89
2x1,5
29
7,5
80
4x1,5
58
9,3
132
2x2,5
48
9,5
130
4x2,5
96
11,5
201
3x0,75
22
7,0
64
5x0,75
36
8,4
100
3x1,0
29
7,1
73
5x1,0
48
8,7
114
3x1,5
43
8,6
104
5x1,5
72
11,0
165
3x2,5
72
10,5
163
5x2,5
120
12,7
253
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 7 D (D – cable diameter).
PP/JZ Flexible cable with electrical protection Standard: PSN Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: flexible copper strand class 5, according to SRPS N.C0.015. Insulation: PVC compound. Core: 2 to 5 cores are stranded together. Filling: suitable material. Electric protection: braid of bare or tinned copper wires. Sheath: PVC compound. Sheath colour can be white, grey or black.
APPLICATION
For connection of mobile user devices at medium mechanical tensile strains, where one cannot expect mechanical damages and electric shock risk, near data processing and data transfer devices and cables.
CONSTRUCTION DATA nxq 2
[mm ]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq 2
[mm ]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
2x0,75
15
8,7
105
4x0,75
29
10,2
143
2x1,0
19
9,5
120
4x1,0
38
11,0
170
2x1,5
29
9,8
133
4x1,5
58
11,7
205
2x2,5
48
12,4
210
4x2,5
96
14,0
305
3x0,75
22
9,3
120
5x0,75
36
11,0
170
3x1,0
29
10,0
140
5x1,0
48
11,8
200
3x1,5
43
11,0
175
5x1,5
72
11,9
235
3x2,5
72
13,1
250
5x2,5
120
15,2
355
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 5D (D – cable diameter).
043
DPP/U
H05VVH6-F
Especially flexible flat cable for cranes Standard: PSN Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: flexible copper strand class 6, according to SRPS N.C0.015. Insulation: PVC compound. Core formation: cores are arranged in groups of 2, 3 or 4 cores laid side by side. Sheath: PVC compound. Sheath colour, grey or black.
In dry and wet conditions as control cable in lifts, cranes, transported lines, machine tools, at medium mechanical tensile strain, when the cable is exposed to severe bending in one plane.
APPLICATION
CONSTRUCTION DATA nxq [mm2]
044
Cu number [kg/km]
Width x height
Mass
[mm]
[kg/km]
4x1
38
12,2x4,4
105
6x1
57
18,4x4,4
159
9x1
86
29,0x4,5
232
12x1
115
35,0x4,5
326
14x1
133
43,1x4,5
353
n – number of the wire, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 4a (a – cable height).
045
SIGNAL CABLES NYY NYBY NYRGY NYSY N2XY
047 048 049 050 051
052 NYSLYCY 053 NYSLYÖ(H05VV5-F) 054 NYSLYCYÖ(H05VVC4V5-F) 055 SEZ 056 SPZ 057 NYSLY
PP 00
NYY
Signal cable with PVC Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: annealed copper wire. Insulation: PVC compound. Core: cores are stranded together, concentric laid. Filling: wrapped thermoplastic tapes or extruded non vulcanized rubber compound layer. Sheath: PVC compound. Sheath colour black.
APPLICATION
In earth, ducts, in the open air, in industrial plants, electric power plants, for connection of control devices in industry and traffic, where one cannot expect mechanical damages. When control cables are parallel laid along with power cables and overhead lines, the care must be taken about those cables' influence to signals being transmitted.
CONSTRUCTION DATA nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
7x1,5
101
13,0
252
7x2,5
168
15,0
347
8x1,5
115
14,0
290
8x2,5
192
16,0
408
10x1,5
144
16,5
345
10x2,5
240
19,0
478
12X1,5
173
17,0
392
12X2,5
288
19,0
559
14X1,5
202
17,5
441
14X2,5
336
20,0
635
16X1,5
230
18,5
500
16X2,5
384
21,0
720
19X1,5
274
19,5
570
19X2,5
456
22,5
813
21X1,5
302
20,0
630
21X2,5
504
23,5
899
24X1,5
346
22,5
708
24X2,5
576
26,0
1051
30X1,5
432
24,0
851
30X2,5
720
28,0
1239
37X1,5
533
26,0
1040
37X2,5
888
30,0
1552
40X1,5
576
27,0
1114
40X2,5
960
31,5
1627
52X1,5
749
30,5
1397
52X2,5
1248
35,0
2105
61X1,5
878
32,0
1671
61X2,5
1464
38,0
2471
n – number of the cores, q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +70°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15 D (D – cable diameter).
047
PP 41
NYBY
Signal cable with PVC Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: annealed copper wire. Insulation: PVC compound. Core: cores are stranded together, concentric laid. Filling: extruded non vulcanized rubber compound layer. Armour: wrapped two steel tapes. Sheath: PVC compound. Sheath colour black.
APPLICATION
For connection of control devices in industry, thermo- and hydroelectric power plants, when additional mechanical protection is required. For laying directly in earth, in ducts and in the open air.
CONSTRUCTION DATA nxq [mm2]
048
Cu number Diameter [kg/km]
[mm]
Mass
nxq
[kg/km]
[mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
7x1,5
101
16,0
433
7x2,5
168
18,0
552
8x1,5
115
17,0
484
8x2,5
192
19,0
619
10x1,5
144
19,5
508
10x2,5
240
21,5
756
12X1,5
173
20,0
694
12X2,5
288
22,5
895
14X1,5
202
20,5
810
14X2,5
336
23,5
1066
16X1,5
230
21,5
893
16X2,5
384
24,0
1200
19X1,5
274
22,5
974
19X2,5
456
26,0
1332
21X1,5
302
23,5
1052
21X2,5
504
27,0
1442
24X1,5
346
26,0
1201
24X2,5
576
29,5
1610
30X1,5
432
27,5
1279
30X2,5
720
31,0
1662
37X1,5
533
29,0
1412
37X2,5
888
34,0
2181
40X1,5
576
30,0
1690
40X2,5
960
35,5
2349
52X1,5
749
34,5
2244
52X2,5
1248
39,5
2897
61X1,5
878
36,0
2344
61X2,5
1464
41,5
3276
n – number of the cores, q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +70°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15 D (D – cable diameter).
PP 44
NYRGY
Signal cable with PVC Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: annealed copper wire. Insulation: PVC compound. Core: cores are stranded together, concentric laid. Filling: extruded non vulcanized rubber compound layer or thermoplastic compound layer. Armour: wrapped round zinc-plated steel wires with or without contra helical zinc-plated steel tape (obligatory when cable is used in mines). Sheath: PVC compound. Sheath colour black.
APPLICATION
For connection of control devices. For laying directly in ground, in cable ducts and in air in industrial plants, power plants, under the traffic lines and along the traffic lines, when the cable is exposed to increased mechanical tensile strain during laying or use. Suitable for vertical or inclined laying along with cable clamps at appropriate distances and with appropriate self-supporting coefficient. For use in mines.
CONSTRUCTION DATA Construction
Cu number
Diameter
Mass
Construction
Cu number
Diameter
Mass
nxq
[kg/km]
[mm]
[kg/km]
nxq
[kg/km]
[mm]
[kg/km]
7x1,5
101
17,0
539
7x2,5
168
20,0
870
8x1,5
115
19,0
764
8x2,5
192
20,0
830
10x1,5
144
20,5
741
10x2,5
240
24,0
1095
12X1,5
173
21,5
872
12X2,5
288
25,0
1392
14X1,5
202
21,0
854
14X2,5
336
25,5
1269
16X1,5
230
23,0
1060
16X2,5
384
27,0
1430
19X1,5
274
24,0
1146
19X2,5
456
28,5
1767
21X1,5
302
26,0
1294
21X2,5
504
29,0
1673
24X1,5
346
27,0
1513
24X2,5
576
32,0
2200
30X1,5
432
29,5
1627
30X2,5
720
33,5
2300
37X1,5
533
32,0
1785
37X2,5
888
36,0
2681
40X1,5
576
31,5
1915
40X2,5
960
37,0
2893
52X1,5
749
38,0
2650
52X2,5
1248
43,0
3520
61X1,5
878
40,0
2950
61X2,5
1464
45,0
3910
n – number of the cores, q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +70°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15 D (D – cable diameter).
049
PP 47
NYSY
Signal cables with PVC Standard: SRPS N.C5.220 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: annealed copper wire. Insulation: PVC compound. Core: cores are stranded together, concentric laid. Filling: extruded non vulcanized rubber compound layer or thermoplastic compound layer. Electrical protection: wrapped annealed copper tape. Sheath: PVC compound. Sheath colour black.
APPLICATION
For connection of control devices in industry, thermo- and hydroelectric power plants, when additional electrical protection is required. The cable is protected from the influence of external interference of adjacent power conductors. Cable can laying in earth, ducts, in the open air, where one cannot expect mechanical damages.
CONSTRUCTION DATA Construction nxq
050
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
Construction nxq
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
7x1,5
165
15,5
374
7x2,5
242
16,0
433
8x1,5
185
15,0
362
8x2,5
273
18,5
557
10x1,5
226
18,5
516
10x2,5
336
21,0
760
12X1,5
257
17,5
481
12X2,5
387
20,5
735
14X1,5
291
20,5
642
14X2,5
440
22,5
831
16X1,5
324
19,0
600
16X2,5
494
23,5
930
19X1,5
373
20,0
675
19X2,5
572
23,0
954
21X1,5
407
21,0
740
21X2,5
627
26,5
1167
24X1,5
462
25,0
947
24X2,5
713
29,0
1332
30X1,5
556
24,5
1004
30X2,5
866
29,0
1434
37X1,5
667
26,5
1197
37X2,5
1048
31,0
1721
40X1,5
715
27,5
1286
40X2,5
1127
32,0
1853
52X1,5
909
31,0
1599
52X2,5
1438
36,5
2358
61X1,5
1049
33,0
1828
61X2,5
1666
38,5
2704
n – number of the cores, q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +70°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15 D (D – cable diameter).
XP 00
N2XY
Signal cable with XLPE insulation Standard: SRPS N.C5.230 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3,5 kV
CONSTRUCTION Conductor: annealed copper wire. Insulation: XLPE compound. Core: cores are stranded together, concentric laid. Filling: wrapped thermoplastic tapes or extruded non vulcanized rubber compound layer. Sheath: PVC compound. Sheath colour black.
APPLICATION
In earth, ducts, in the open air, in industrial plants, electric power plants, for connection of control devices in industry and traffic, where one cannot expect mechanical damages. When control cables are parallel laid along with power cables and overhead lines, the care must be taken about those cables' influence to signals being transmitted.
CONSTRUCTION DATA Construction nxq
Cu number Diameter [kg/km]
[mm]
Mass
Construction
[kg/km]
nxq
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
7x1,5
101
12,5
213
7x2,5
168
13,5
291
8x1,5
115
13,5
242
8x2,5
192
14,5
333
10x1,5
144
15,5
281
10x2,5
240
17,0
402
12X1,5
173
15,5
330
12X2,5
288
17,5
462
14X1,5
202
16,5
373
14X2,5
336
18,0
524
16X1,5
230
17,5
420
16X2,5
384
19,0
594
19X1,5
274
18,0
477
19X2,5
456
20,0
680
21X1,5
302
19,0
524
21X2,5
504
21,0
749
24X1,5
346
21,0
591
24X2,5
576
23,5
846
30X1,5
432
22,0
709
30X2,5
720
25,0
1046
37X1,5
533
24,5
873
37X2,5
888
27,0
1262
40X1,5
576
25,0
939
40X2,5
960
28,0
1360
52X1,5
749
28,5
1182
52X2,5
1248
31,5
1723
61X1,5
878
30,0
1361
61X2,5
1464
33,5
1993
n – number of the cores, q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C. Permissible environment temperature: - at laying and handling, min +5°C. Smallest bending radius: 15 D (D – cable diameter).
051
NYSLY, NYSLY- JZ Flexible signal cable Standard: DIN VDE 0245 part 102 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper stranded class 5, according to DIN VDE 0295. Insulation: special PVC compound. Core: cores are stranded together, concentric laid. The cores are black, marked with numbers. When green/yellow core exists (type code: -JZ), it is laid in outer layer. Sheath: special PVC compound. Sheath colour grey.
In dry and wet conditions as supply cable or remote control and signal cable in assembling lines, machine tools, automatics, etc., at medium mechanical strains. Not designed for laying in the open air.
APPLICATION
CONSTRUCTION DATA Mass n x q Cu number Diameter [mm2] [kg/km] [mm] [kg/km]
052
nxq [mm2]
Cu number Diameter
[kg/km]
[mm]
Mass Mass n x q Cu number Diameter 2 [kg/km] [mm ] [kg/km] [mm] [kg/km]
3x0,5
14.4
6,3
53
3x0,75
22
6,8
64
3x1
29
7,2
4x0,5
20
6,9
63
4x0,75
29
7,4
77
4x1
39
7,9
75 91
5x0,5
24
7,5
74
5x0,75
36
8,5
98
5x1
48
9,0
116
7x0,5
34
9,1
101
7x0,75
51
9,6
124
7x1
68
10,1
148
12x0,5
58
11,5
171
12x0,75
87
12,3
212
12x1
116
13,2
252
19x0,5
92
13,3
240
19x0,75
137
14,3
301
19x1
183
16,0
383
25x0,5
120
16,1
337
25x0,75
180
17,3
420
25x1
240
19,1
528
27x0,5
130
16,4
352
27x0,75
195
17,7
440
27x1
260
19,5
553
34x0,5
164
18,8
442
34x0,75
245
20,1
551
34x1
327
21,5
661
37x0,5
178
19,2
473
37x0,75
267
20,5
591
37x1
356
22,1
710
44x0,5
211
21,5
567
44x0,75
317
23,2
709
44x1
422
25,4
885
50x0,5
240
22,0
643
50x0,75
360
23,7
804
50x1
480
25,3
965
61x0,5
293
23,8
752
61x0,75
439
25,7
945
61x1
586
28,1
1174
3x1,5
44
7,9
94
3x2,5
72
9,8
152
4x1,5
58
8,8
122
4x2,5
96
11,1
197
5x1,5
72
9,6
145
5x2,5
120
11,9
234
7x1,5
101
11,3
197
7x2,5
168
13,3
303
Permissible conductor temperature: - operating temperature, max +70°C; - in short circuit (max 5 s), max +150°C.
12x1,5
173
14,0
320
12x2,5
288
18,0
522
19x1,5
274
17,0
488
19x2,5
456
21,6
788
25x1,5
360
20,3
669
25x2,5
600
25,8
1074
27x1,5
389
20,8
704
27x2,5
648
26,4
1130
34x1,5
490
22,8
847
34x2,5
816
28,6
1363
37x1,5
533
23,5
912
37x2,5
888
29,8
1467
44x1,5
634
27,0
1130
44x2,5
1056
34,2
1810
50x1,5
720
27,5
1275
50x2,5
1200
34,8
2032
37,8
2407
61x1,5 878 29,9 1507 61x2,5 1464 n – number of the cores, q – nominal cross section conductor
Permissible environment temperature: - at laying and handling, from +5°C to +70°C; - for moving from + 5°C to + 70°C; - for fixed from - 30°C to + 70°C. Smallest bending radius: 7D (D – cable diameter).
NYSLYCY Flexible signal cable with electrical protection Standard: DIN VDE 0245 part 102 Nominal voltage U0/U: 300/500 V Test voltage: 2 кV
CONSTRUCTION Conductor: annealed copper strand class 5, according to DIN VDE 0295. Insulation: special PVC compound. Core: cores are stranded together, concentric laid. Inner sheath: PVC compound. Screen: braid of tinned copper wires. Outer sheath: Special PVC compound. Sheath colour grey.
In dry and wet conditions as supply cable or remote control and signal cable in assembling lines, machine tools, automatics, etc., at medium mechanical strains. Not designed for laying in the open air.
APPLICATION
CONSTRUCTION DATA nxq [mm2]
Cu number Diameter
[kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter
[kg/km]
[mm]
Mass
nxq 2 [kg/km] [mm ]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
3x0,5
35
8,6
99
3x0,75
44
9,0
113
3x1
53
9,6
133
4x0,5
43
9,3
118
4x0,75
54
10,2
144
4x1
65
10,7
162
5x0,5
49
10,4
141
5x0,75
63
10,9
163
5x1
77
11,4
185
7x0,5
61
11,0
166
7x0,75
80
11,6
194
7x1
99
12,2
222
12x0,5
107
13,9
263
12x0,75
139
14,7
310
12x1
174
16,6
394
19x0,5
150
16,8
382
19x0,75
200
17,8
453
19x1
250
19,4
548
25x0,5
189
19,5
505
25x0,75
254
20,7
600
25x1
321
22,3
716
27x0,5
200
18,6
473
27x0,75
270
20,5
596
27x1
342
22,7
744
34x0,5
238
21,1
599
34x0,75
328
22,8
742
34x1
415
24,8
895
37x0,5
256
21,1
608
37x0,75
353
23,5
788
37x1
448
24,9
919
44x0,5
301
24,3
772
44x0,75
414
25,9
930
44x1
526
27,5
1088
50x0,5
354
25,4
877
50x0,75
483
27,1
1054
50x1
615
29,1
1260
61x0,5
417
27,2
1003
61x0,75
576
29,5
1242
61x1
732
31,9
1495
3x1,5
69
10,5
163
3x2,5
104
12,2
228
4x1,5
86
11,2
189
4x2,5
131
13,3
275
5x1,5
103
12,0
218
5x2,5
172
14,6
332
7x1,5
135
13,0
272
7x2,5
225
15,6
409
12x1,5
235
17,4
470
12x2,5
365
21,4
710
19x1,5
346
20,4
663
19x2,5
548
25,5
1031
25x1,5
446
24,2
899
25x2,5
738
29,6
1380
27x1,5
477
24,0
906
27x2,5
789
30,2
1439
34x1,5
609
26,3
1119
34x2,5
968
32,8
1733
37x1,5
657
26,5
1158
37x2,5
1045
33,2
1807
44x1,5
775
30,3
1440
44x2,5
1235
37,8
2233
50x1,5
864
31,3
1591
50x2,5
1419
39,2
2499
61x1,5
1035
33,7
1846
61x2,5
1663
42,0
2869
n – number of the cores, q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +70°C; - in short circuit (max 5 s), max +150°C. Permissible environment temperature: - at laying and handling, from +5°C to +70°C; - for moving from + 5°C to + 70°C; - for fixed from - 30°C to + 70°C. Smallest bending radius: 7D (D – cable diameter).
053
NYSLYО
H05VV5-F, NSKK/F
Flexible oil-resistant signal cable Standard: DIN VDE 0281 part 13 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper strand class 5, according to DIN VDE 295. Insulation: special PVC compound. Core: cores are stranded together, concentric laid. Green/yellow core is laid in outer layer. Sheath: special PVC compound layer, oil-resistant. Sheath colour grey.
In dry and wet conditions as supply cable or remote control and signal cable in assembling lines, machine tools, automatics, etc., at medium mechanical strains. Not designed for laying in the open air. Due to cable chemical characteristics, it is suitable for usage in breweries and washing plants.
APPLICATION
CONSTRUCTION DATA nxq [mm2]
054
Cu number Diameter
[kg/km]
[mm]
Mass [kg/km]
nxq [mm2]
Cu number Diameter
[kg/km]
[mm]
Mass
Mass n x q Cu number Diameter 2 [mm ] [kg/km] [kg/km] [mm] [kg/km]
3x0,5
14.4
6,3
53
3x0,75
22
6,8
64
3x1
29
7,2
4x0,5
20
6,9
63
4x0,75
29
7,4
77
4x1
39
7,9
75 91
5x0,5
24
7,5
74
5x0,75
36
8,5
98
5x1
48
9,0
116
7x0,5
34
9,1
101
7x0,75
51
9,6
124
7x1
68
10,1
148
12x0,5
58
11,5
171
12x0,75
87
12,3
212
12x1
116
13,2
252
19x0,5
92
13,3
240
19x0,75
137
14,3
301
19x1
183
16,0
383
25x0,5
120
16,1
337
25x0,75
180
17,3
420
25x1
240
19,1
528
27x0,5
130
16,4
352
27x0,75
195
17,7
440
27x1
260
19,5
553
34x0,5
164
18,8
442
34x0,75
245
20,1
551
34x1
327
21,5
661
37x0,5
178
19,2
473
37x0,75
267
20,5
591
37x1
356
22,1
710
44x0,5
211
21,5
567
44x0,75
317
23,2
709
44x1
422
25,4
885
50x0,5
240
22,0
643
50x0,75
360
23,7
804
50x1
480
25,3
965
61x0,5
293
23,8
752
61x0,75
439
25,7
945
61x1
586
28,1
1174
3x1,5
44
7,9
94
3x2,5
72
9,8
152
4x1,5
58
8,8
122
4x2,5
96
11,1
197
5x1,5
72
9,6
145
5x2,5
120
11,9
234
7x1,5
101
11,3
197
7x2,5
168
13,3
303
12x1,5
173
14,0
320
12x2,5
288
18,0
522
19x1,5
274
17,0
488
19x2,5
456
21,6
788
25x1,5
360
20,3
669
25x2,5
600
25,8
1074
27x1,5
389
20,8
704
27x2,5
648
26,4
1130
34x1,5
490
22,8
847
34x2,5
816
28,6
1363
37x1,5
533
23,5
912
37x2,5
888
29,8
1467
44x1,5
634
27,0
1130
44x2,5
1056
34,2
1810
50x1,5
720
27,5
1275
50x2,5
1200
34,8
2032
61x1,5
878
29,9
1507
61x2,5
1464
37,8
2407
n – number of the cores, q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +70°C; - in short circuit (max 5 s), max +150°C. Permissible environment temperature: - at laying and handling, from +5°C to +70°C; - for moving from + 5°C to + 70°C; - for fixed from - 30°C to + 70°C. Smallest bending radius: 7,5D (D – cable diameter)
NYSLYCYÖ
H05VVC4V5-K, NSKKE/F
Flexible oil-resistant signal cable with electrical protection Standard: DIN VDE 0281 part 13 Nominal voltage: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper strand class 5, according to DIN VDE 295. Insulation: special PVC compound. Core: cores are stranded together, concentric laid. Green/yellow core is laid in outer layer. Inner sheath: PVC compound. Screen: braid of tinned copper wires. Sheath: special PVC compound layer, oil-resistant. Sheath colour grey.
In dry and wet conditions as supply cable or remote control and signal cable in assembling lines, machine tools, automatics, etc., at medium mechanical strains. Not designed for laying in the open air.
APPLICATION
CONSTRUCTION DATA nxq [mm2]
Cu number
Diameter
Mass
[kg/km]
[mm]
3x0,5 4x0,5 5x0,5 7x0,5 12x0,5 19x0,5 25x0,5 27x0,5 34x0,5 37x0,5 44x0,5 50x0,5 61x0,5
35 43 49 61 107 150 189 200 238 256 301 354 417
3x1,5 4x1,5 5x1,5 7x1,5 12x1,5 19x1,5 25x1,5 27x1,5 34x1,5 37x1,5 44x1,5 50x1,5 61x1,5
69 86 103 135 235 346 446 477 609 657 775 864 1035
Mass
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
9,6 10,7 11,4 12,2 16,6 19,4 22,3 22,7 24,8 24,9 27,5 29,1 31,9
133 162 185 222 394 548 716 744 895 919 1088 1260 1495
Cu number
Diameter
[kg/km]
nxq [mm2]
[kg/km]
[mm]
8,6 9,3 10,4 11,0 13,9 16,8 19,5 18,6 21,1 21,1 24,3 25,4 27,2
99 118 141 166 263 382 505 473 599 608 772 877 1003
3x0,75 4x0,75 5x0,75 7x0,75 12x0,75 19x0,75 25x0,75 27x0,75 34x0,75 37x0,75 44x0,75 50x0,75 61x0,75
44 54 63 80 139 200 254 270 328 353 414 483 576
9,0 10,2 10,9 11,6 14,7 17,8 20,7 20,5 22,8 23,5 25,9 27,1 29,5
113 144 163 194 310 453 600 596 742 788 930 1054 1242
3x1 4x1 5x1 7x1 12x1 19x1 25x1 27x1 34x1 37x1 44x1 50x1 61x1
10,5 11,2 12,0 13,0 17,4 20,4 24,2 24,0 26,3 26,5 30,3 31,3 33,7
163 189 218 272 470 663 899 906 1119 1158 1440 1591 1846
3x2,5 4x2,5 5x2,5 7x2,5 12x2,5 19x2,5 25x2,5 27x2,5 34x2,5 37x2,5 44x2,5 50x2,5 61x2,5
104 131 172 225 365 548 738 789 968 1045 1235 1419 1663
12,2 13,3 14,6 15,6 21,4 25,5 29,6 30,2 32,8 33,2 37,8 39,2 42,0
228 275 332 409 710 1031 1380 1439 1733 1807 2233 2499 2869
Permissible conductor temperature: - operating temperature, max +70°C; - in short circuit (max 5 s), max +150°C.
n – number cores, q – nominal cross section conductor
nxq 2 [kg/km] [mm ]
53 65 77 99 174 250 321 342 415 448 526 615 732
Permissible environment temperature: - at laying and handling, from +5°C to +70°C; - for moving from + 5°C to + 70°C; - for fixed from - 30°C to + 70°C. Smallest bending radius: 7,5D (D – cable diameter)
055
SEZ Railway station signal safety cable with PE insulation Standard: JŽS S2.011
CONSTRUCTION Conductor: annealed copper wire 0.9 mm diameter and 1.4 mm diameter. Insulation: polyethylene (PE). Core: cores are stranded, concentric laid. Inner covering: thermoplastic tape. Inner sheath: PVC compound. Armour: steel tape wrapping with a gap. Outer sheath: PVC compound. Sheath colour black.
APPLICATION
Cable is intended for connecting remote safety control and signal devices at electrified railways. For laying in earth, in ducts, indoors.
ELECTRICAL CHARACTERISTICS Characteristics
Value for conductor diameter 0,9 [mm] 1,4 [mm]
Unit
Conductor resistance, max
Ω/км
28.9
11.9
Insulation resistance, min
M oм* км
10000
10000
Mutual capacitance, max Dialectic strenght wire/wire
nF/км
100
120
Veff
2000
2000
CONSTRUCTION DATA
056
nxd [mm]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
nxd [mm]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x0.9
12
9.0
153
2x1.4
30
10.5
200
4x0.9
24
10.5
160
4x1.4
59
13.0
224
5x0.9
31
11.0
181
5x1.4
74
13.5
268
8x0.9
49
12.5
224
8x1.4
118
15.5
350
12x0.9
73
14.5
307
12x1.4
177
17.5
480
16x0.9
98
15.5
360
16x1.4
237
18.0
584
21x0.9
128
16.5
423
21x1.4
310
21.0
724
27x0.9
165
18.0
500
27x1.4
399
24.0
922
33x0.9
201
19.5
606
33x1.4
488
26.5
1150
40x0.9
244
21.5
721
40x1.4
591
28.0
1260
48x0.9
293
23.5
821
48x1.4
710
29.0
1419
56x0.9
342
24.5
913
56x1.4
828
30.5
1770
61x0.9
372
25.0
964
61x1.4
902
31.5
1729
n – number of the cores, d – nominal diameter conductor
Operating temperature of conductor, max +70°C Permissible environment temperature at laying and handling from -5°C to +50°C Smallest bending radius: 15D (D – cable diameter)
SPZ Railway station signal safety cable with PVC insulation Standard: JŽS S2.011
CONSTRUCTION Conductor: annealed copper wire 0.9 mm diameter and 1.4 mm diameter. Insulation: PVC compound. Core: cores are stranded, concentric laid. Inner covering: thermoplastic tape. Inner sheath: PVC compound. Armour: steel tape wrapping with a gap. Outer sheath: PVC compound. Sheath colour black.
APPLICATION
Cable is intended for connecting remote safety control and signal devices at electrified railways. For laying in earth, in ducts, indoors.
ELECTRICAL CHARACTERISTICS Characteristics
Value for conductor diameter
Unit
0,9 [mm]
1,4 [mm]
Conductor resistance, max
Ω/km
28.9
11.9
Insulation resistance, min
M oм* км
100
100
Mutual capacitance, max
nF/км
180
210
Veff
2000
2000
Dialectic strenght wire/wire
CONSTRUCTION DATA nxd [mm]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
nxd [mm]
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x0.9
12
9.0
155
2x1.4
30
10.5
205
4x0.9
24
11.0
174
4x1.4
59
12.5
236
5x0.9
31
12.0
196
5x1.4
74
13.5
271
8x0.9
49
13.0
242
8x1.4
118
15.0
359
12x0.9
73
14.5
321
12x1.4
177
17.5
505
16x0.9
98
16.0
385
16x1.4
237
19.0
618
21x0.9
128
17.5
460
21x1.4
310
21.0
770
27x0.9
165
18.5
530
27x1.4
399
24.0
980
33x0.9
201
19.5
610
33x1.4
488
25.5
1141
40x0.9
244
22.0
762
40x1.4
591
27.5
1318
48x0.9
293
23.5
869
48x1.4
710
29.5
1524
56x0.9
342
25.0
968
56x1.4
828
31.5
1681
61x0.9
372
25.5
1025
61x1.4
902
33.5
1881
n – number of the cores, d – nominal diameter conductor
Operating temperature of conductor, max +70°C Permissible environment temperature at laying and handling, from -5°C to +50°C Smallest bending radius: 15D (D – cable diameter)
057
RUBBER CABLES H01N2-E, -D H05RR-F H05RN-F NFK EpG NFK TES ZEpN, BT, HT NSGAFöu KPSRM PPSRVM PPSRMO
059 060 061 062 063 064 065 066 067 068
NGFLGöu NFK SiSi/JU NSHTöu Si/F NFK SiSi/J NSSHöu NFK EpN 50 H07RN-F NSSHöu.../3E NSSHöu...KON
069 070 071 072 073 074 075 076 077 078
EpN 58 NSSHCGEöu...+üI NSSHCGEöu.../3 NSSHCGEöu...+St+ üI NSSHCGEöu.../KON+St+üI NTSCGECWöu...KON NTSCGECWöu...KON NTSCGERWöu...KON NTSCGEWöu.../3
NTSCGEWöu.../3E+St+ üI MGG,MGCG, FMGCG
079 080 081 082 083 084 085 086 087 088 089
H01N2-D; ZN/S
H01N2-E
Flexible welding cable
Especially flexible welding cable
Standard: DIN VDE 0282-6, HD 22.6 Nominal voltage U0/U: 100/100 V Test voltage: 1 kV
CONSTRUCTION Conductor: fine stranded copper conductor, (H01N2-D), fine stranded, especially flexible, copper conductor (H01N2-E). Sheath: based on polychloroprene rubber, (EM5) oil resistant, and flame retardant. Sheath colour black.
APPLICATION
Cable can use in dry, damp and wet location and outdoors. Cable is intended for machine and hand welding.
CONSTRUCTION DATA
q [mm2]
H01N2-D
Cu number [kg/km]
H01N2-E
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
10
96
9
150
7
125
16
154
10
220
8
185
25
240
12
305
10
275
35
336
13
340
12
381
50
480
15
557
14
523
70
672
17
773
16
722
95
912
20
1024
18
954
120
1152
22
1309
20
1212
150
1440
25
1588
22
1495
185
1776
27
2004
24
1899
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +85°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min - 20°C, - for storage from + 10°C to + 40°C. Smallest bending radius: 4D for H01N2-D; 3D for H01N2-E (D - cable diameter).
059
H05RR-F
ПРС
Flexible cable with rubber insulation and sheath Standard: DIN VDE 0282-4, HD 22.4 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on EPR rubber (EI4). Sheath: based on EPR rubber (EM3). Sheath colour black.
Cable can use in dry locations such as homes and offices for supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances).
APPLICATION
It can not be used for fixed laying in open air.
CONSTRUCTION DATA nxq [mm2]
060
Cu number Diameter [kg/km]
[mm]
Mass
nxq
[kg/km]
[mm2]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
2x0,75
15
6,8
55
4G0,75
29
8,0
78
2x1
20
7,3
65
4G1
39
8,5
95
2x1,5
29
8,8
97
4G1,5
58
10,5
144
2x2,5
48
10,3
137
4G2,5
96
12,0
210
3G0,75
22
7,4
69
4G4
154
14,5
314
3G1
29
7,7
79
4G6
231
16,6
432
3G1,5
44
9,3
116
5G0,75
36
9,0
104
3G2,5
72
11,0
168
5G1
48
9,3
119
3G4
116
13,0
247
5G1,5
72
11,5
177
3G6
173
15,0
341
5G2,5
120
13,5
268
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min -25°C, - for storage from +10°C to +40°C. Smallest bending radius: 3D (D - cable diameter).
H05RN-F Flexible rubber cable Standard: DIN VDE 0282-4, HD 22.4 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on EPR rubber (EI4). Sheath: based on polychloroprene rubber (EM2), oil resistant, flame retardant.
APPLICATION
Cable can be used in dry locations such as homes and offices for supplying portable or light mobile appliances with low mechanical stresses. One-wire cable can be used for a range of bulbs for the New Year's tree and a similar purpose.
CONSTRUCTION DATA nxq
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
1x0,75
8
4,4
27
1x1
10
4,5
30
1x1,5
15
4,8
36
2x0,75
15
6,8
60
2x1
20
7,3
71
3G0,75
22
7,4
74
3G1
29
7,7
84
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +60°C, - in short circuit (max 5 s), max +200°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 3D (D - cable diameter).
061
NFK EpG, NFK EpN Flexible cables for mobile appliances Standard: PSN Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on EPR rubber. Sheath: based on natural/synthetic rubber for type NFK EpG, based on polychloroprene rubber for type NFK EpN. All colours are permitted except red, blue and yellow.
Cable can be used in dry locations such as homes and offices for supplying portable or light mobile appliances with low mechanical stresses (e.g. vacuum cleaners, electric irons, cooking appliances), as well as for light machines in agriculture and industry with medium mechanical stresses.
APPLICATION
CONSTRUCTION DATA nxq 2
[mm ]
062
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq 2
[mm ]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
2x0,75
15
6,2
54
4x4
154
14,0
319
2x1
20
6,8
71
4x6
17
16,7
470
2x1,5
29
8,3
92
5x0,75
36
9,0
113
2x2,5
48
9,8
138
5x1
48
9,5
133
3x0,75
22
6,8
68
5x1,5
72
10,7
178
3x1
29
7,2
78
5x2,5
120
12,9
265
3x1,5
44
8,8
117
5x4
192
15,2
397
3x2,5
72
10,4
169
5x6
288
18,3
582
3x4
116
12,6
254
7x0,75
51
10,0
146
3x6
173
15,0
371
7x1
68
10,6
173
4x0,75
29
7,7
91
7x1,5
101
12,6
242
4x1
39
8,6
106
7x2,5
168
14,4
343
4x1,5
58
9,8
145
7x4
269
17,3
512
4x2,5
96
11,6
213
7x6
404
20,0
745
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -25°C, - for storage from +10°C to +40°C. Smallest bending radius: 4D (D - cable diameter).
NFK TES Flexible cable for submersible pumps Standard: PSN Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
CONSTRUCTION Conductor: flexible copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on synthetic rubber (if exists). Sheath: specially adapted compositions based on rubber. Sheath colour black.
The cable is intended for connection submersible pumps.
APPLICATION CONSTRUCTION DATA nxq [mm2]
Cu number Diameter [kg/km]
[mm]
Mass
nxq
[kg/km]
[mm2]
1x25
240,0
14,0
383
4G1,5
1x35
336,0
16,0
505
1x70
672,0
21,0
931
1x95
912,0
24,0
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
57,6
11,5
183
4G2,5
96,0
13,5
264
4G4
153,6
16,0
373
1227
4G6
230,4
18,0
496
2x2,5
48,0
11,5
179
4G10
384,0
24,0
933
2x4
76,8
13,5
237
4G16
614,4
27,0
1274
2x6
115,2
14,5
320
4G25
960,0
32,5
1756
2x10
192,0
20,0
612
4G35
1344,0
37,0
2415
2x16
307,2
23,0
810
4G50
1920,0
42,0
3186
2x25
480,0
27,5
1150
4G70
2688,0
49,0
4241
3G1,5
43,2
10,5
151
4G95
3648,0
55,0
5710
3G2,5
72,0
12,5
217
5G2,5
120,0
15,0
323
3G4
115,2
15,0
301
5G10
480,0
26,0
1135
3G6
172,8
16,0
393
5G16
768,0
30,0
1572
3G16
460,8
25,0
1009
12G1,5
172,8
20,0
507
3G25
720,0
29,5
1419
19G2,5
456,0
28,0
1118
3G35
1008,0
33,0
1724
24G1,5
345,6
28,0
951
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: from -30°C to +70°C. Smallest bending radius: 4D (D - cable diameter).
063
ŽEpN; BT/HT Railway cables with rubber insulation and sheath Standard: SRPS N.C3.350 for ŽEpN UIC 895 for BT i HT Nominal voltage: 750V 1500V 3000V Test voltage: 2 kV 6 kV 12 kV
CONSTRUCTION Conductor: copper conductor class 5 and class 6. Separator: suitable tape. Insulation: based on EPR rubber. Sheath: based on chlorosulphonated polyethylene rubber, oil, fat and fuel resistant, flame retardant. Sheath colour black.
APPLICATION
Cable is used in electrical vehicles for current circuits, for current circuits for heating and control, as well as for lighting.
CONSTRUCTION DATA Construction
064
750V
1500V
3000V
q
Cu number
Diameter
Mass
Diameter
Mass
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
1,5
15
5,2
45
7,6
81
9,6
119
2,5
24
5,9
60
8,1
95
10,1
133
4
39
6,6
81
8,6
116
10,6
157
6
58
7,6
112
9,7
150
11,7
198
10
96
8,9
171
10,9
217
12,7
263
16
154
10,5
245
12,1
285
13,9
335
25
240
12,4
360
13,6
396
15,4
454
35
336
14,0
480
15,2
517
17,0
581
50
480
15,0
645
17,4
705
19,2
775
70
672
18,0
890
19,2
930
21,0
1010
95
912
20,4
1135
21,8
1205
23,6
1290
120
1152
22,5
1425
23,9
1496
25,7
1595
150
1440
24,9
1755
25,9
1815
27,9
1930
185
1776
27,5
2125
28,9
2217
30,1
2295
240
2304
30,1
2735
32,7
2928
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -20°C, - in use, min -40°C. Smallest bending radius: 6D (D - cable diameter).
32,9
2930
NSGAöu, NSGAFöu Railway cables with rubber insulation and sheath Standard: DIN VDE 0250-602 Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
1,8/3 kV 6 kV
3,6/6 kV 11 kV
CONSTRUCTION Conductor: tinned copper conductor class 1 and class 2 for NSGAöu and tinned copper conductor class 5 for NSGAFöu. Separator: suitable tape, for 6 kV semi-conductive tape. Insulation: based on EPR rubber (3GI3). Sheath: based on polychloroprene rubber (5GM3), oil, fat and fuel resistant; flame retardant. Sheath colour black.
APPLICATION
Cable is used in electrical vehicles for current circuits, for current circuits for heating and control, as well as for lighting.
CONSTRUCTION DATA Construction q 2
[mm ] 1,5
0,6/1 kV
1,8/3 kV
3,6/6 kV
Cu number
Diameter
Mass
Diameter
Mass
Diameter
Mass
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
15
5,1
38
6,1
57
8,7
97
2,5
24
5,7
50
6,5
73
9,1
110
4
39
6,4
72
7,0
90
9,6
128
6
58
7,3
95
7,8
112
10,5
155
10
96
8,6
146
9,1
158
11,3
223
16
154
9,4
198
10,4
223
13,0
285
25
240
11,2
296
12,4
329
14,6
389
35
336
13,3
420
14,1
478
16,3
546
50
480
15,4
574
15,9
594
18,1
665
70
672
17,3
783
17,7
803
19,9
889
95
912
19,4
992
20,2
1047
21,6
1125
120
1152
21,7
1235
22,5
1293
24,9
1369
150
1440
23,6
1570
24,4
1685
26,4
1704
185
1776
25,6
1920
26,0
2060
27,6
2150
240
2304
30,0
2490
30,2
2520
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -20°C, - in use, min -40°C. Smallest bending radius: 6D (D - cable diameter).
065
КПСРМ Railway cable with rubber insulation and sheath Standard: PSN Nominal voltage: Test voltage:
660V 3 kV
CONSTRUCTION Conductor: copper conductor class 5. Separator: suitable tape. Insulation: based on EPR rubber, number stamped wire. Sheath: based on polychloroprene rubber, oil, fat and fuel resistant; flame retardant. Sheath colour black.
Cable is used in electrical vehicles for current circuits, for current circuits for heating and control, as well as for lighting.
APPLICATION CONSTRUCTION DATA
nxq [mm2]
066
Cu number Diameter
[kg/km]
[mm]
Mass
nxq
[kg/km]
[mm2]
Cu number Diameter
[kg/km]
[mm]
Mass [kg/km]
7x1,5
101
6,8
324
7x2,5
168
19
451
10x1,5
144
7,3
463
10x2,5
240
22
662
12x1,5
173
8,8
514
12x2,5
288
24
717
14x1,5
202
10,3
577
14x2,5
336
24
817
16x1,5
231
7,4
648
16x2,5
384
27
965
19x1,5
274
7,7
747
19x2,5
456
29
1095
24x1,5
346
9,3
989
30x2,5
720
35
1456
37x1,5
533
11,0
1462
37x2,5
888
39
2072
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -20°C, - in use, min -45°C. Smallest bending radius: 4D (D - cable diameter).
ППСРВМ Railway cable with rubber insulation and sheath Standard: PSN Nominal voltage: Test voltage:
1500V 6 kV
3000V 12 kV
4000V 16 kV
CONSTRUCTION Conductor: copper conductor class 5. Separator: suitable tape. Insulation: based on EPR rubber. Sheath: based on polychloroprene rubber, oil, fat and fuel resistant; flame retardant. Sheath colour black.
APPLICATION
Cable is used in electrical vehicles for current circuits, for current circuits for heating and control, as well as for lighting.
CONSTRUCTION DATA q
Cu number
[mm2]
[kg/km]
1500V
3000V
4000V
Diameter
Mass
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
1,5
15
7,7
65
8,6
87
11,6
149
2,5
24
8,5
80
9,1
97
12,1
163
4
39
8,8
101
10,6
126
13,6
195
6
58
10,6
142
11,7
165
14,5
238
10
96
12,4
201
13,3
227
15,7
313
16
154
14,5
295
15,1
315
17,9
405
25
240
16,4
410
17,6
446
19,4
534
35
336
19,0
560
20,2
597
21,0
711
50
480
21,0
725
21,4
775
23,2
885
70
672
22,0
980
23,2
1030
26,0
1170
95
912
24,4
1255
25,8
1335
26,6
1440
120
1152
27,5
1555
27,9
1626
29,7
1725
150
1440
30,9
1885
29,9
1955
32,9
2100
185
1776
31,5
2295
32,9
2357
34,1
2455
240
2304
36,1
2925
36,7
2978
37,9
2990
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -20°C, - in use, min -45°C. Smallest bending radius: 4D (D - cable diameter).
067
ППСРМO Railway cable with rubber insulation and sheath Standard: PSN Nominal voltage: Test voltage:
1500V 6 kV
3000V 12 kV
4000V 16 kV
CONSTRUCTION Conductor: copper conductor class 5. Separator: suitable tape. Insulation: based on EPR rubber, number stamped wire. Sheath: based on polychloroprene rubber, oil, fat and fuel resistant; flame retardant. Sheath colour black.
APPLICATION
Cable is used in electrical vehicles for current circuits, for current circuits for heating and control, as well as for lighting.
CONSTRUCTION DATA
068
q
Cu number
[mm2]
[kg/km]
1500 V
3000 V
4000 V
Diameter
Mass
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
1,0
10
5,2
43
6,2
55
8,6
99
1,5
15
5,6
52
6,6
66
9,0
119
2,5
24
6,5
68
7,1
84
9,8
133
4
39
6,8
85
7,6
96
10,6
157
6
58
7,9
112
8,7
136
11,5
198
10
96
9,4
171
10,4
197
12,7
263
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying, min -20°C, - in use, min -45°C. Smallest bending radius: 4D (D - cable diameter).
NGFLGöu Flat rubber cable Standard: DIN VDE 0250-809 Nominal voltage U0/U: 300/500 V Test voltage: 3 kV
CONSTRUCTION Conductor: copper conductor class 5 and class 6. Insulation: based on EPR rubber. Sheath: based on polychloroprene rubber (5GM2), oil and fat resistant. Sheath colour black.
Cable is used as power, signal and control cable in dry, damp and wet location and outdoors with medium mechanical stresses and torsion. There is in one plane. Cable is used for connecting mobile parts of the machines, conveyor systems and large machines. Cable can be used in dry and wet areas and outdoors, exposed to high mechanical stresses and the rolling, placed in a plane
APPLICATION
CONSTRUCTION DATA
nxq 2
[mm ]
Cu number
Outer dimension (height x width)
[kg/km]
Mass
min
max
[mm]
[mm]
[kg/km]
3x4
116
7,9x16,5
9,6x21,0
294
3x95
2736
22,0x53,0
26,9x66,0
3977
4x2,5
96
6,6x18,5
8,2x24,0
271
4x6
231
8,5x24,5
10,4x31,0
517
4x16
615
11,5x35,0
14,0x44,0
1068
4x70
2688
19,5x62,5
23,7x78,0
3958
5x6
288
8,5x29,5
10,4x37,5
784
7x2,5
168
6,6x31,0
8,2x39,5
538
7x4
269
7,9x37,0
9,6x46,5
657
12x2,5
288
7,2x50,5
8,8x63,5
802
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +60°C, - fixed laying from -40°C to +60°C. Smallest bending radius: 4a (a - cable height).
069
NFK SiSi/JU Flexible flat silicone rubber cable Standard: PSN Nominal voltage U0/U: 300/500 kV Test voltage: 2 kV
CONSTRUCTION Conductor: copper conductor class 5 and class 6. Insulation: based on silicone rubber. Sheath: based on silicone rubber.
Cable is used as power, signal and control cable in dry, damp and wet location and outdoors with medium mechanical stresses and torsion. There is in one plane. Cable is used for connecting mobile parts of the machines, conveyor systems and large machines. Cable can be used in dry and wet areas and outdoors, exposed to high mechanical stresses and the rolling, placed in a plane.
APPLICATION
CONSTRUCTION DATA
070
nxq
Cu number
[mm2]
[kg/km]
Outer dimension (height x width) min
max
[mm]
[mm]
Mass [kg/km]
3x4
116
7,9x16,5
9,6x21,0
294
3x95
2736
22,0x53,0
26,9x66,0
3977
4x2,5
96
6,6x18,5
8,2x24,0
271
4x6
231
8,5x24,5
10,4x31,0
517
4x16
615
11,5x35,0
14,0x44,0
1068
4x70
2688
19,5x62,5
23,7x78,0
3958
5x6
288
8,5x29,5
10,4x37,5
784
7x2,5
168
6,6x31,0
8,2x39,5
538
7x4
269
7,9x37,0
9,6x46,5
657
12x2,5
288
7,2x50,5
8,8x63,5
802
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +180°C, - in short circuit (max 5 s), max +350°C. Permissible environment temperature: - mobile from -30°C to +200°C, - fixed laying from -50°C to +250°C. Smallest bending radius: 4a (a - cable height).
NFK EpTN, NSHTöu Especially flexible cables with torsion protection Standard: DIN VDE 0250/814, for NSHTöu
PSN, for NFK EpTN Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber (3GI3). Inner sheath: based on natural/synthetic rubber (GM1b), chlorosulphonated polyethylene for special application. Torsion protection: braid with cord. Sheath: based on polychloroprene rubber (5GM2), chlorosulphonated polyethylene for special application. Sheath colour yellow for NFK EpTN, black for NSHTöu.
The cable is intended for connecting mobile devices with a large mechanical stresses in dry, wet and huge humidity areas and outdoors. The cable is very convenient if there is a strain due rolling.
APPLICATION
CONSTRUCTION DATA nxq
Cu
number
[mm2] [kg/km]
Diameter
[mm]
Mass
nxq
Cu
number
[kg/km] [mm2] [kg/km]
Diameter Mass
[mm] [kg/km]
nxq [mm2]
Cu number
[kg/km]
Diameter
Mass
[mm]
[kg/km]
3x1,5
44
13
227 4x25
960
35
2024
7x2,5
168
18
480
3x2,5
72
15
290 4x35
1344
39
2744
7x4
269
25
848
3x4
116
19
456 4x50
1920
44
3591
7x16
1076
38
2441
3x16
461
25
1172 4x70
2688
50
4805
10x1,5
144
20
489
3x25
720
32
1680 4x95
3648
56
6592
12x2,5
288
25
870
58
14
261 4x120
4608
64
8041
14x1,5
202
23
720
4x4
154
18
486 5x2,5
120
18
455
14x2,5
336
27
955
4x6
231
21
667 5x6
288
23
856
18x1,5
260
26
876
4x10
384
26
1016 7x1,5
101
17
397
18x2,5
432
28
1147
4x1,5
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +50°C, - fixed laying from -40°C to +50°C. Smallest bending radius: 5D (D - cable diameter).
071
Si/F
H05S
Flexible cable for higher temperature Standard: SRPS N.C3.410 Nominal voltage U0/U: 300/500 V Test voltage: 2 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on silicone rubber.
Silicone installation wires are intended for electric power installation at place where temperature is higher than temperature environment or below 0°C.
APPLICATION
CONSTRUCTION DATA q
Cu number Diameter
[mm2]
072
[kg/km]
[mm]
Mass
q
Cu number
Diameter
Mass
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
1
10
2,6
14
35
336
11,0
360
1,5
15
3,0
19
50
480
13,0
518
2,5
24
3,5
31
70
672
14,0
697
4
39
4,0
45
95
912
17,0
929
6
58
5,2
63
120
1152
19,5
1180
10
96
6,5
113
150
1440
22,3
1510
16
154
7,6
118
185
1776
23,0
1840
25
240
9,0
262
240
2304
28,3
2500
q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +180°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -50°C to +180°C, - fixed laying from -60°C to +200°C. Smallest bending radius: 4D (D - cable diameter).
NFK SiSi/J Flexible cable for higher temperature Standard: PSN Nominal voltage U0/U: 300/500 V Test voltage: 1,5 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on silicone rubber. Sheath: based on silicone rubber.
Cable can be used for connecting mobile appliances in dry, damp and wet rooms as well as outdoors with low mechanical stresses.
APPLICATION CONSTRUCTION DATA nxq 2
[mm ]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
nxq 2
[mm ]
Cu number Diameter [kg/km]
[mm]
Mass [kg/km]
2x1
20
6,9
68
4x1
39
8,0
99
2x1,5
29
8,0
81
4x1,5
58
9,5
124
2x2,5
48
9,5
129
4x2,5
96
11,2
186
2x4
77
10,7
180
4x4
154
12,6
288
3x1
29
7,2
74
4x6
231
14,0
435
3x1,5
44
8,5
99
5x1,5
72
10,3
178
3x2,5
72
10,1
147
5x2,5
120
12,5
240
3x4
116
11,4
205
7x1,5
101
11,4
196
3x6
173
12,6
329
7x2,5
168
13,3
310
n – number of the cores; q – nominal cross section conductor
Permissible conductor temperature: - operating temperature, max +180°C, - in short circuit (max 5 s), max +350°C. Permissible environment temperature: - mobile from -50°C to +180°C, - fixed laying from -60°C to +200°C. Smallest bending radius: 4D (D - cable diameter).
073
NSSHöu Flexible low voltage mining cable Standard: DIN VDE 0250 part 812 Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on natural/synthetic rubber. Sheath: based on polychloroprene rubber. Sheath colour yellow.
Cables are intended for the operations in heavy conditions, in surface and methanes pit mines, shipyards, quarries and other types of industry. Can be used for fixed laying in dry and humid environments.
APPLICATION
CONSTRUCTION DATA nxq
074
Cu number Diameter
Mass
nxq
[kg/km]
[mm2]
Cu Diameter number
Mass
nxq
[kg/km]
[mm2]
Cu Diameter number
Mass
[mm2]
[kg/km]
1x50
480
18
680
3x95
2740
51
4750
4x95
3650
54
5750
1x70
680
20
910
3x120
3460
55
5590
4x120
4610
62
7480
1x150
1440
27
1830
3x70+35
1780
46
3910
5x1,5
72
14
290
1x240
2310
34
2930
3x95+50
3220
56
5730
5x2,5
120
17
420
1x300
2880
37
3580
3x120+70
4130
59
6280
5x4
195
19
560
2x50
960
37
2170
4x1,5
58
13
240
5x6
290
22
710
2x70
1350
42
2840
4x2,5
96
16
360
5x10
480
26
1090
2x95
1830
46
3500
4x4
154
18
470
5x16
770
30
1550
3x1,5
44
13
210
4x6
235
20
580
5x25
1200
36
2260
3x2,5
72
14
270
4x10
385
24
950
7x1,5
1002
18
410
3x4
116
17
390
4x16
615
29
1380
10x1,5
145
20
485
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
3x6
175
18
480
4x25
960
33
2000
12x1,5
175
22
590
3x35
1110
34
1980
4x35
1345
38
2460
12x2,5
290
24
795
3x50
1440
42
2850
4x50
1920
44
3460
15x2,5
360
26
970
3x70
2020
44
3430
4x70
2690
48
4510
18x2,5
435
24
1140
n – number of the cores; q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
NFK EpN 50 Flexible mining cable with torsion protection Standard: PSN 03F041 Nominal voltage U0/U: 450/750 V Test voltage: 2,5 kV
0,6/1 kV 3 kV
CONSTRUCTION
Conductor: copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on synthetic rubber. Torsion protection: braid with cord. Sheath: based on polychloroprene rubber. Sheath colour black.
APPLICATION
Cable can be used in dry, damp and wet location and outdoors where there is no danger of the explosion. Cable is used for connection appliances with medium mechanical stresses for machines in civil-engineering, in agricultural operating area and electric appliances in mine pit without methan. Cable is recomended if torsion stress exists. Cable is used as a signal and control cable, as well as for fixed installation.
CONSTRUCTION DATA nxq
Cu number Diameter
Mass
nxq [mm2]
[mm2]
[kg/km]
[mm]
[kg/km]
7x1,5
101
15
324
10x1,5
144
19
12x1,5
173
14x1,5
Cu number Diameter
Mass
[kg/km]
[mm]
7x2,5
168
18
461
463
10x2,5
240
22
662
20
514
12x2,5
288
23
737
202
21
577
14x2,5
336
24
817
19x1,5
274
23
737
19x2,5
456
27
1045
24x1,5
346
27
949
30x2,5
720
33
1606
n – number of the cores; q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
[kg/km]
075
EpN 50, GN 50
КГ; H07RN-F
Flexible rubber cables Standard: SRPS N.C5.350 Nominal voltage U0/U: 450/750 V Test voltage: 2,5 kV
CONSTRUCTION Conductor: copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on natural/synthetic rubber for type GN 50, based on polychloroprene rubber for type EpN 50. Sheath: based on polychloroprene rubber. Sheath colour black.
Cable can be used in dry, damp and wet location, outdoors and in places where there is no danger of the explosion. Cable is used for connection appliances with medium mechanical stresses for machines in civil-engineering, in agricultural operating area and electric appliances in mine pit without methane.
APPLICATION
CONSTRUCTION DATA
076
nxq
Cu
Diameter
Mass
nxq
Cu
Diameter
Mass
nxq
Cu
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
1x1,5
15
6
52
2x10
192
20
612
4x2,5
96
14
264
1x2,5
24
7
68
2x16
307
23
810
4x4
154
16
373
1x4
39
8
93
2x25
480
28
1150
4x6
231
18
496
1x6
58
9
119
3x1
29
10
120
4x10
384
24
933
1x10
96
11
200
3x1,5
44
11
151
4x16
615
27
1274
1x16
154
12
274
3x2,5
72
13
217
4x25
960
33
1756
1x25
240
14
383
3x4
116
15
301
4x35
1344
37
2415
1x35
336
16
505
3x6
173
16
393
4x50
1920
42
3186
1x50
480
19
692
3x10
288
22
758
4x70
2688
49
4241
1x70
672
21
931
3x16
461
25
1009
4x95
3648
55
5710
1x95
912
24
1227
3x25
720
30
1419
4x120
4608
60
7007
1x120
1152
26
1520
3x35
1008
33
1724
4x150
5760
66
8603
1x150
1440
28
1866
3x50
1440
38
2493
5x1
48
12
181
1x185
1776
31
2298
3x70
2016
45
3309
5x1,5
72
13
224
1x240
2304
35
2908
3x95
2736
49
4423
5x2,5
120
15
323
2x1
19
9
100
3x120
3456
54
5486
5x4
192
18
460
2x1,5
29
10
125
3x150
4320
59
6713
5x6
288
20
610
2x2,5
48
12
179
3x185
5328
65
8193
5x10
480
26
1135
2x4
77
14
237
4x1
39
11
146
5x16
768
30
1572
2x6
116
15
320
4x1,5
58
12
183
5x25
1200
36
2165
n – number of the cores; q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C; fixed laying from -30°C to +40°C. Smallest bending radius: from 3D to 12D (D - cable diameter).
EpN 53
NSSHöu .../3E
Flexible low voltage mining cable Standard: SRPS N.C5.353 Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
CONSTRUCTION Conductor: flexible copper conductor class 5. Insulation: based on EPR rubber. Protective conductor: braid of the tinned copper wires. Inner sheath: based on synthetic rubber. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow for power cable, grey for signal and control cables.
APPLICATION
Cable is intended for connecting of various users in mines with underground exploitation, where danger of methane and coal-dust explosion is present. It can be used as power or signal-control cable.
CONSTRUCTION DATA nxq/q1 [mm2]
Cu number Diameter
Mass
nxq/q1 [mm2]
[kg/km]
[mm]
[kg/km]
3x2,5/2,5
96
18
384
3x4/4
154
20
3x6/6
231
3x10/10
Cu number Diameter
Mass
[kg/km]
[mm]
[kg/km]
3x70/35
2352
51
4563
560
4x2,5/2,5
120
20
511
24
730
4x4/4
192
21
652
384
25
1045
4x6/6
288
25
1034
3x16/16
615
30
1542
4x10/10
480
29
1414
3x25/16
874
33
1784
5x2,5/2,5
144
22
645
3x35/16
1162
38
2351
5x4/4
231
23
790
3x50/25
1680
47
3345
5x10/10
346
28
1130
n – number of the cores; q – nominal cross section conductor; q1– nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
077
EpN 55
NSSHöu ... KON
Flexible low voltage mining cable Standard: SRPS N.C5.353 Nominal voltage U0/U: 0,6/1 kV Test voltage: 2,5 kV
CONSTRUCTION Conductor: flexible copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on synthetic rubber. Protective conductor: braid of the tinned copper wires over semi- conductive tape. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow for power, grey for signal and control cables.
APPLICATION
Cable is intended for connecting of various users in mines with underground exploitation, where danger of methane and coal-dust explosion is present. It can be used as power or control cable.
CONSTRUCTION DATA nxq/q1 [mm2]
078
Cu number Diameter
Mass
nxq/q1
[kg/km]
[mm2]
[kg/km]
[mm]
3x2,5/2,5
96
17
353
3x4/4
154
19
3x6/6
231
3x10/10
Cu number Diameter
Mass
[kg/km]
[mm]
[kg/km]
4x2,5/2,5
120
19
433
516
4x4/4
192
20
592
23
698
4x6/6
288
23
782
384
24
929
4x10/10
480
28
1255
3x16/16
615
29
1360
5x2,5/2,5
144
20
557
3x25/16
874
32
1685
5x4/4
231
21
658
3x35/16
1162
36
2287
5x6/6
346
27
1006
3x50/25
1680
44
3037
19x1,5/4
312
27
929
3x70/35
2352
49
4458
25x1,5/4
399
29
996
n – number of the cores; q – nominal cross section conductor; q1– nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
EpN 58 Very flexible low voltage mining cable Standard: SRPS N.C5.358 Nominal voltage U0/U: 450/750 V Test voltage: 2,5 kV
CONSTRUCTION Conductor: flexible copper conductor class 5. Insulation: based on EPR rubber. Inner sheath: based on synthetic rubber. Torsion protection: braid of cord. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow.
APPLICATION
Cable is intended for supplying rotation drilling machines in mines with underground pit.
CONSTRUCTION DATA nxq
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
44
14
238
4x6
231
21
651
5x2,5
120
18
438
5x4
192
21
609
5x6
288
24
844
5x10
480
27
1209
3x1,5
n – number of the cores; q – nominal cross section conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 4D (D - cable diameter).
079
EpN 60
NSSHCGEöu ... +ϋl
Flexible low voltage mining cable Standard: SRPS N.C5.360 Nominal voltage U0//U: 0,6/1 kV Test voltage: 3 kV
CONSTRUCTION Power cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Protective core Conductor: flexible tinned copper conductor class 5. Semi conductive layer: rubber compound /tape. Core cable: 3 power cores with 1 protective core placed in the space between power cores. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow.
APPLICATION
The cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits), the power of machines, devices and appliances, electric lighting and for auxiliary circuits.
CONSTRUCTION DATA 3xq + 1xq1
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
96
19
430
3x4+1x4
154
21
575
3x6+1x6
231
24
750
3x10+1x10
384
28
1100
3x16+1x16
615
30
1400
3x2,5+1x2,5
080
q – nominal cross section power conductor; q1– nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
EpN 61
NSSHCGEöu .../3
Flexible low voltage mining cable Standard: SRPS N.C5.360 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3 kV
CONSTRUCTION Power cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Protective cores Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound /tape. Core cable: 3 power cores and 3 protective cores placed in the space between power cores. Inner sheath: based on natural/ synthetic rubber. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow.
APPLICATION
The cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits), the power of machines, devices and appliances, electric lighting and for auxiliary circuits.
CONSTRUCTION DATA 3xq + 3xq1/3
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
3x25+3x10/3
836
34
1430
3x35+3x10/3
1125
39
2260
3x50+3x10/3
1555
44
2713
3x70+3x10/3
2132
49
3720
3x95+3x10/3
2852
55
4850
3x120+3x10/3
3572
56
5885
3x150+3x10/3
4436
60
7050
q – nominal cross section power conductor; q1– nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
081
EpN 62
NSSHCGEöu ... +St+ϋl
Flexible low voltage mining cable Standard: SRPS N.C5.360 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3 kV for power; 2 kV for command
CONSTRUCTION Power cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Command cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Protective core Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound /tape. Core cable: 3 power cores and 2 command and 1 protective core placed in the space between power cores. Inner sheath: based on natural/ synthetic rubber. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow.
APPLICATION
The cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits), the power of machines, devices and appliances, electric lighting and for auxiliary circuits.
CONSTRUCTION DATA
082
3xq + 2xq1 + 1xq2
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
3x16+2x6+1x10
672
32
1320
3x25+2x6+1x10
932
36
1880
3x35+2x6+1x10
1220
39
2560
3x50+2x6+1x10
1652
44
3480
q – nominal cross section power conductor q1 – nominal cross section command conductor q2 – nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 5D (D - cable diameter).
EpN 63
NSSHCGEöu .../KON+St+ϋl
Flexible low voltage mining cable Standard: SRPS N.C5.360 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3 kV for power; 2 kV for command
CONSTRUCTION Power cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Command cores Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Control core Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound /tape. Core cable: 3 power cores and 2 command and 1 control core placed in the space between power cores. Inner sheath: based on natural/ synthetic rubber. Screen: tinned copper wires or stranded wires or combine tinned copper and zinc plated steel wires. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour yellow.
APPLICATION
The cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits). It is used for connecting machines for cutting and loading coal, machines for making underground corridor, as well as for supplying appliances and devices, electrical lighting and auxiliary electrical circuits.
CONSTRUCTION DATA 3xq/q0 + 2xq1 + 1xq2
Cu number
Diameter
Mass
[mm ]
[kg/km]
[mm]
[kg/km]
3x25/16+2x4+1x10
1047
40
2501
3x35/10+2x6+1x10
1316
44
2797
3x35/16+2x6+1x10
1335
46
3095
3x50/25+2x6+1x10
1892
48
3728
3x70/16+2x6+1x10
2381
53
4671
2
3x70/35+2x4+1x10
2525
55
5697
3x95/16+2x10+1x10
3178
58
5942
3x95/35+2x4+1x10
3245
62
6291
q – nominal cross section power conductor; q0 – nominal cross section protective coductor q1 – nominal cross section command conductor; q2 – nominal cross section control conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C,
- fixed laying from -30°C to +40°C.
Smallest bending radius: 5D (D - cable diameter).
083
EpN 64
NTSCGECWöu ... KON
Flexible medium voltage mining cable Standard: SRPS N.C5.364 Nominal voltage U0/U: 3,6/6 kV Test voltage: 11 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Insulation: based on EPR rubber. Inner sheath: based on natural/synthetic rubber. Protective conductor: tinned copper wires. Separation sheath: based on EPR rubber. Command conductor: tinned copper wires. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour red.
APPLICATION
Flexible rubbed cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits). The cable is used for connecting high voltage movable transformer.
CONSTRUCTION DATA
084
3xq / q1/ q2
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
3x16/10/4
749
50
2810
3x25/16/4
1104
52
3240
3x35/16/4
1488
57
4170
3x50/25/4
2016
60
4628
q – nominal cross section power conductor q1 – nominal cross section protective conductor q2 – nominal cross section command conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 15D (D - cable diameter).
EpN 65
NTSCGECWöu ... KON
Flexible medium voltage mining cable Standard: SRPS N.C5.364 Nominal voltage U0/U: 3,6/6 kV Test voltage: 11 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Inner sheath: semi conductive rubber. Protective conductor: tinned copper wires. Separation sheath: based on EPR rubber. Command conductor: tinned copper wires. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour red.
APPLICATION
Flexible rubbed cable is intended for use in mines with underground pits, threatened by fire and gas and coal dust explosion (methane pits). The cable is used for connecting high voltage movable transformer.
CONSTRUCTION DATA 3xq/ q1/ q2
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
3x16/10/4
596
53
3116
3x25/16/4
912
55
3350
3x35/16/4
1200
57
4270
3x50/25/4
1719
58
4722
3x50/25/6
1738
59
4798
3x/50/35/4
1815
68
5255
q – nominal cross section power conductor q1 – nominal cross section protective conductor q2 – nominal cross section command conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 15D (D - cable diameter).
085
EpN 74
NTSCGERWöu ... KON
Flexible medium voltage mining cable Standard: SRPS N.C5.374 Nominal voltage U0/U: 3,6/6 kV 6/10 kV 12/20 kV 18/30 kV Test voltage: 11 kV 17 kV 29 kV 43 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Inner sheath: based on natural/synthetic rubber. Protective conductor: tinned copper wires or stranded wires or combine tinned copper and zinc plated steel wires. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour, red.
Flexible medium voltage mining cable is used in the surface pit mines, quarries and shipyards to supply heavy moving machines, excavators, cranes and similar in terms of large mechanical stresses, especially the large centrifugal forces.
APPLICATION
CONSTRUCTION DATA 3xq/ q1 2
[mm ]
086
3,6/6 kV
Cu number
6/10 kV
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
[kg/km]
3x16/16
615
3x25/16
874
46
2942
3x25/25
960
49
3016
3x35/25
1248
51
3530
3x35/35
1344
53
3633
3x50/25
1680
56
4221
3x50/35
1776
57
4361
3x70/35
2352
58
5139
3x95/50
3216
62
6278
3x120/50
3935
73
8253
3x150/50
4800
76
9418
3x185/70
6000
79
10994
50
2821
52
3296
56
3963
60
4752
66
6840
80
10354
q – nominal cross section power conductor; q1 – nominal cross section protective conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - mobile from -25°C to +40°C, - fixed laying from -30°C to +40°C. Smallest bending radius: 12D (D - cable diameter).
EpN 78
NTSCGEWöu ... /3
Flexible medium voltage mining cable Standard: SRPS N.C5.374 Nominal voltage U0/U: 3,6/6 kV 6/10 kV 12/20 kV 18/30 kV Test voltage: 11 kV 17 kV 29 kV 43 kV
CONSTRUCTION Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Insulation: based on EPR rubber. Protective conductor: tinned copper conductor class 5 with semi conductive layer. Core cable: 3 power cores and 3 protective cores placed in the space between power cores. Inner sheath: based on natural/synthetic rubber. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour red.
APPLICATION
Cables are intended for operating in extremely heavy conditions on surface pit mines, shipyards, quarries and industry. They are suitable for supply of heavy excavators, cranes truck transporters loading bridges and other machines. They are very flexible and possible for continuous movement.
CONSTRUCTION DATA 3,6/6 kV
6/10 kV
12/20 kV
nxq + n1xq1
Cu number
[mm2]
[kg/km]
3x16 + 3x6
634
42
2196
44
2341
–
–
749 1008 1181 1296 1469
42 44 44 47 47
2303 2679 2815 3212 3347
– 46 – 49 49
– 2825 – 3365 3506
– – – – –
– – – – –
4414
64
3x16 3x25 3x25 3x35 3x35
+ + + + +
3x10 3x10 3x16 3x10 3x16
Diameter [mm]
Mass [kg/km]
Diameter [mm]
Mass [kg/km]
Diameter [mm]
3x50 + 3x16
1901
52
4024
55
3x50 + 3x25
2160
52
4220
–
–
–
3x70 + 3x16
2477
57
5151
–
–
72
3x70 + 3x25 3x95 + 3x16 3x95 + 3x25 3x120 + 3x16
2736 3197 3456 3917
57 61 61 66
5347 6100 6295 7189
– 63 – –
3x120 + 3x25
4176
66
7349
–
3x120 + 3x35
4464
66
7685
68
3x150 3x150 3x185 3x185 3x185
5040 5328 6048 6336 6768
71 71 73 73 73
8773 8973 10193 10393 10702
– – 75 – –
– – 10370 – –
+ + + + +
3x25 3x35 3x25 3x35 3x50
6081 – 7026
– 6309 – –
– – – –
– – – –
–
–
–
7614
–
–
– – – – –
– – – – –
n – number of the power cores; q – nominal cross section power conductor n1 – number of the protective cores; q1 – nominal cross section protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible environment temperature: mobile from -25°C to +40°C; fixed laying from -30°C to +40°C. Smallest bending radius: 12D (D - cable diameter).
Mass [kg/km]
087
NFK EpN 78/53
NTSCGEWöu ... /3E+St+ϋl
Flexible medium voltage mining cable Standard: PSN 03J080 Nominal voltage U0/U: 3,6/6 kV 6/10 kV Test voltage: 11 kV 17 kV
CONSTRUCTION Power cores Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Screen: braid of tinned copper wires. Command conductor Conductor: tinned copper conductor class 5. Insulation: based on EPR rubber. Semi conductive layer: rubber compound/tape. Protective conductors Conductor: tinned copper conductor class 5. Semi conductive layer: rubber compound/tape. Cable core: 3 power cores and 1 command - control and 2 protective cores placed in the space between power cores. Inner sheath: based on natural/synthetic rubber. Sheath: based on polychloroprene rubber, oil and abrasion resistant, flame retardant. Sheath colour red.
Flexible medium voltage mining cable is used in extremely heavy conditions. It can be used on surface pit mines, shipyards, quarries and industry for supplying excavators, cranes and other machines.
APPLICATION
088
CONSTRUCTION DATA 3xq + 2xq1 + 1xq2 2
[mm ]
Cu number [kg/km]
3,6/6 kV Diameter [mm]
6/10 kV
Mass [kg/km]
3x16 + 2x6 + 10
672
44
2688
3x25 + 2x10 + 10
1008
45
3008
3x35 + 2x10 + 10
1296
49
3451
3x35 + 2x16 + 10
1412
49
3667
3x50 + 2x16 + 16
1901
53
4465
3x50 + 2x25 + 10
2016
53
4750
3x50 + 2x25 + 16
2074
53
4931
3x70 + 2x35 + 16
2842
60
6093
Diameter [mm] 52
3636
57
4543
q – nominal cross section power conductor; q1 – nominal cross section protective conductor q2 – nominal cross section command conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible environment temperature: mobile from -25°C to +40°C; fixed laying from -30°C to +40°C. Smallest bending radius: 12D (D - cable diameter).
Mass [kg/km]
MGG Power shipboard cable Standard: DIN 89160 Nominal voltage U0/U: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor class 2. Insulation: based on hard EPR grade (HEPR ). Filler: rubber compound/tape. Sheath: based on poychloroprene rubber (SЕ-1). Sheath colour black.
MGCG Power shipboard cable with screen Standard: DIN 89158 Nominal voltage U0/U: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor class 2. Insulation: based on hard EPR grade (HEPR). Filler: rubber compound/tape. Protective conductor: braid of copper wires. Sheath: based on poychloroprene rubber (SE-1). Sheath colour black.
FMGCG
089
Telecommunication shipboard cable Standard: DIN 89159 Nominal voltage: 250 V
CONSTRUCTION Conductor: tinned copper conductor class 2. Insulation: based on hard EPR grade (HEPR). Elements of the cable: pairs. Filler: rubber compound/tape. Protective conductor: braid of copper wires. Sheath: based on poychloroprene rubber (SE-1). Sheath colour black.
APPLICATION
Used for fixed laying on ships and off-shore units, use in all rooms and on open boards, as power, signalling and control cables. Cable does not spread fire and flame.
TELECOMUNICATION CABLES TK59 DSL TK59 DSL -120 2YY J-YY J-Y(ST)Y JE-Y(ST)Y TI 20 TM 20 TC 44 TI 44
091 092 093 094 095 096 097 098 099 100
TZ 44 TSV TK 33 U TK 39 M, GM TK 59 M, GM TK 59 TP TK 59 GMR TPP TPPEP A-02Y(L)2Y
101 102 103 104 105 106 107 108 109 110
A-2Y(L)2Y A-2YF(L)2Y TD 59 UP TD 59M, GM TB-TZB TG-TZG S-YY S-Y(ST)Y TO SM 03 TO SM 19
111 112 113 114 115 116 117 118 119 120
TK59 DSL (30)... M, TK59 DSL (30)... GM, Filled high-frequency cable for digital transmission Standard: TS001/2009
CONSTRUCTION Conductor: soft annealed copper wire of 0,4 and 0.6 mm diameter. Insulation: foam-skin PE. Twisting elements: pairs. Cable core: group or concentric stranded. Filling: compound with drop point above 70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath. Sheath colour black.
APPLICATION
In local network for DSL (Digital Subscriber Lines) and subscription lines, laid in cable channelling or directly into the ground.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual values average values Insulation resistance, min Working capacity, max Coupling capacity, max K coupling E coupling Dielectric strength wire/wire wire/screen Characteristic impedance
Ω/km
Value for conductor diameter 0,4 mm 0,6 mm 300 290 5
130 126 5
42
42
pF/300 m
400 1600
400 1600
Veff/V
500/700 2000/2800 135 ± 15%
500/700 2000/2800 135 ± 15%
GΩ km nF/km
Ω
CONSTRUCTION DATA Construction 10X2 20X2 30X2 40X2 50X2 70X2 100X2 150X2 200X2 300X2 600X2
For conductor 0,4 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 24 12.0 130 49 15.0 190 73 16.0 245 98 18.0 300 122 19.5 365 183 22.0 510 245 25.0 630 367 29.5 885 490 33.0 1130 734 39.5 1640 1469 54.0 3185
For conductor 0,6 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 54 14.0 190 108 17.0 290 163 19.5 405 217 21.5 490 271 23.0 610 380 27.0 795 542 31.0 1085 814 37.0 1600 1085 41.5 2050 1627 50.0 3000
091
TK59 DSL (30)... M, TK59 DSL (30)... GM, Filled high-frequency cable for digital transmission Standard: TS001/2009
CONSTRUCTION Conductor: soft annealed copper wire of 0,4 and 0.6 mm diameter. Insulation: foam-skin PE. Twisting elements: pairs. Cable core: group or concentric stranded. Filling: compound with drop point above 70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath. Sheath colour black.
In local network for DSL (Digital Subscriber Lines) and subscription lines, laid in cable channelling or directly into the ground.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual values average values Insulation resistance, min
Ω/km GΩ km nF/km
Working capacity, max
092
Coupling capacity, max K coupling E coupling Dielectric strength wire/wire wire/screen Characteristic impedance
pf/km Veff/V Ω
Value for conductor diameter 0,4 mm 0,6 mm 300 290 5
130 126 5
50
50
400 1600
400 1600
500/700 2000/2800 120 ± 15%
500/700 2000/2800 120 ± 15%
CONSTRUCTION DATA For conductor 0,4 mm Construction 10X2 20X2 30X2 40X2 50X2 70X2 100X2 150X2 200X2 300X2 600X2
For conductor 0,6 mm
Cu number
Diameter
Mass
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
[kg/km]
[mm]
[kg/km]
24 49 73 98 122 183 245 367 490 734 1469
12.0 15.0 16.0 18.0 19.5 22.0 25.0 29.5 33.0 39.5 54.0
130 190 245 300 365 510 630 885 1130 1640 3185
54 108 163 217 271 380 542 814 1085 1627
14.0 17.0 19.5 21.5 23.0 27.0 31.0 37.0 41.5 50.0
190 290 405 490 610 795 1085 1600 2050 3000
2YY Leading insulated conductor Standard: VDE 0815
CONSTRUCTION Conductor: soft annealed copper wire of 1 mm diameter. Insulation: solid PE. Sheath: PVC compound. Sheath colour black.
Cable is used as leading conductor in dry and damp operating areas.
APPLICATION
ELECTRICAL CHARACTERISTICS Value for
Characteristic
Unit
Conductor resistance, max
Ω/km
23,4
Insulation resistance, min
GΩ km
5
Veff
2 000
V
900
Dielectric strength Operating voltage, max
1,0 mm
CONSTRUCTION DATA
093
For conductor 1,0 mm Construction
1x1
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
9,6
3,5
14
J-YY ... Bd Installation cable Standard: VDE 0815
CONSTRUCTION Conductor: soft annealed copper wire of 0,6 mm diameter. Insulation: PVC compound. Twisting elements: star quads. Cable core: group stranded. Core wrapping: thermoplastic tapes in several layers. Sheath: PVC compound. Sheath colour grey, RAL 7032.
Cable is used for installation lines or introducing several lines into buildings.
APPLICATION
ELECTRICAL CHARACTERISTICS Unit
Loop resistance, max
Ω/km
130
Insulation resistance, min
MΩ km
100
Mutual capacitance, max
nF/km
100
pF/100 m
300* 100**
Coupling capacitance k, max k1 k9-12 Dielectric strength wire/wire
Veff
Operating voltage, peak value * 20 % of value, but min. one value, may amount up to 500 pF ** 10 % of value, but min. one value, may amount up to 300 pF
094
Value for
Characteristic
V
1,0 mm
800 300
CONSTRUCTION DATA For conductor 1,0 mm Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x2
30
5.0
30
4x2
60
6.5
50
6x2
90
7.5
70
10x2
151
9.0
110
20x2
301
11.5
190
24x2
362
13.0
230
30x2
452
14.0
280
40x2
603
16.0
360
50x2
754
17.5
440
60x2
904
19.0
540
80x2
1206
21.5
690
100x2
1507
24.0
870
J-Y(St)Y ... Installation cable Standard: VDE 0815
CONSTRUCTION Conductor: soft annealed copper wire of 0,6 and 0,8 mm diameter. Insulation: PVC compound. Twisting elements: pairs, except two pairs being twisted to star quads. Cable core: concentric stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire longitudinally applied under it. Sheath: PVC compound. Sheath colour grey.
For installation line or introducing several lines into buildings.
APPLICATION
ELECTRICAL CHARACTERISTICS Unit
Characteristic
Loop resistance, max Ω/km Insulation resistance, min MΩ km Mutual capacitance, max nF/km Coupling capacitance k, max pF/100 m Dielectric strength Veff wire/wire wire/screen Operating voltage, peak value V * in case of two pair cables the values can be exceeded by 20 % ** 20 % of value, but min. one value, may amount up to 500 pF
Value for 0,6 mm 130 100 100* 200**
0,8 mm 73.2 100 100* 300**
500 2000 300
800 800 300
CONSTRUCTION DATA Construction
For conductor 0,6 mm Cu number Diameter Mass [kg/km] [mm] [kg/km]
For conductor 0,8 mm Cu number Diameter Mass [kg/km] [mm] [kg/km]
1x2 2x2 3x2 4x2 5x2 6x2 8x2 10x2 12x2 14x2 16x2 20x2 24x2 30x2 40x2 50x2 60x2 80x2 100x2
6 12 17 23 29 35 46 58 69 81 92 115 138 173 230 288 346 461 576
4.8 5.0 6.3 7.2 7.9 8.4 9.0 9.7 10.1 10.6 11.1 12.6 13.6 14.6 16.4 17.8 19.6 22.0 24.8
26 35 52 61 72 84 106 122 136 150 167 212 248 297 372 469 561 700 903
11 21 32 42 53 63 84 106 148 158 169 211 253 317 422 528 634 845 1056
6.0 6.7 8.8 9.7 10.4 11.6 11.9 14.1 15.2 15.6 16.0 17.4 19.8 21.0 24.2 26.5 29.2 33.0 36.8
38 56 76 102 119 141 166 224 276 296 307 371 475 544 685 876 1021 1400 1760
1x3
9
5.1
30
16
6.3
48
095
JE-Y(St)Y...Bd Installation cable for electronics Standard: VDE 0815
CONSTRUCTION Conductor: soft annealed copper wire with 0,8 mm diameter. Insulation: PVC compound. Twisting elements: pairs. Cable core: group stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire longitudinally applied under it. Sheath: PVC compound. Sheath colour grey.
Cable is intended electronics.
APPLICATION
for
permanent
connection
in
industrial
ELECTRICAL CHARACTERISTICS Value for
Characteristic
Unit
Loop resistance, max
Ω/km
73,2
Insulation resistance, min
MΩ km
100
Mutual capacitance, max
nF/km
100*
pF/100 m
200**
Coupling capacitance k, max
0,8 mm
Dielectric strength wire/wire
Veff
wire/screen Operating voltage, peak value
96
* **
500 2 000
V
225
in case of two pair cables the values can be exceeded by 20 % 20 % of value, but min. one value, may amount up to 400 pF
CONSTRUCTION DATA For conductor 0,8 mm Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x2
21
7.0
50
4x2
40
9.0
90
8x2
79
11.0
150
12x2
118
13.5
220
16x2
156
15.0
280
20x2
195
16.0
340
32x2
311
20.0
530
40x2
388
22.0
640
80x2
774
30.0
1250
TI 20 Telephone installation cable Standard: SRPS N.C2.220
CONSTRUCTION Conductor: soft annealed copper or tin wire of 0,5; 0,6 and 0,8 mm diameter. Insulation: PVC compound. Twisting elements: pairs, triples, quads.
Cable is intended for telephone installations in buildings, installed in tubes. It may be used for connection to loudspeakers, signal units, for shunting and wiring of cable distributors.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Conductor resistance, max, at 20°C Insulation resistance, min, at 60°C Dielectric strength (1 minute)
Value for 0,5 mm
0,6 mm
0,8 mm
Ω/km
92.65
63.95
35.97
MΩ km
0.165
0.148
0.110
Veff
2000
2000
2000
CONSTRUCTION DATA For conductor 0,5 mm Construction
Cu number Diameter
Mass
[kg/km]
[mm]
1x
1,9
1.3
3.5
2x
3,8
2.6
7.0
3x
5,7
2.8
4x
7,5
3.2
For conductor 0,6 mm Cu number Diameter
[kg/km] [kg/km]
Mass
For conductor 0,8 mm Cu number Diameter
Mass
[mm]
[kg/km]
[kg/km]
[mm]
[kg/km]
2,7
1.4
4.5
4,8
1.6
6.5
5,4
2.8
8.5
9,6
3.2
13.5
12.0
8,1
3.1
14.5
14,5
3.5
20.5
14.0
10,9
3.4
17.5
19,3
3.9
26.5
97
TM 20 Telephone cable for internal wiring Standard: SRPS N.C2.420
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0,5; 0,6; 0,8; 1,0; 1,2 and 1,4 mm diameter. Insulation: PVC compound.
It can use for internal connections in telecommunication devices and sets or for their connection.
APPLICATION
ELECTRICAL CHARACTERISTICS
Unit
0,4 mm
0,5 mm
0,6 mm
0,8 mm
1,0 mm
1,2 mm
1,4 mm
Conductor resistance, max, at 20°C
Ω/km
145
93
63
35.5
23
16
11.7
Insulation resistance, min, at 60°C
MΩ km
1.1
1.0
0.95
0.8
0.75
0.65
0.65
Veff
2000
2000
2000
2000
2000
2000
2000
Characteristic
Dielectric strength (1 minute)
98 CONSTRUCTION DATA Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
1x0.4
1,2
0.8
1.8
1x0.5
1,9
1.0
2.6
1x0.6
2,7
1.1
3.6
1x0.8
4,8
1.3
6.0
1x1.0
7,5
1.6
9.5
1x1.2
10,9
1.8
13.0
1x1.4
14,8
2.0
17.5
TC44 ... E, TC44 ... GE Switchboard cable for telephone exchanges Standard: SRPS N.C4.140
CONSTRUCTION Conductor: Soft annealed tin copper wire of 0,5 and 0,6 mm diameter. Insulation: PVC compound. Twisting elements: pairs, triples, quads, quintuples. Cable core: concentric stranded. Core wrapping: thermoplastic tapes in several layers. For TC 44 EK Screen: laminated aluminium foil with a tinned copper drain wire longitudinally applied under it. Sheath: PVC compound. Sheath colour grey.
APPLICATION
Cable is intended for internal connections in telephone exchanges and signalling units.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Insulation resistance, min Mutual capacitance, max Coupling capacitance, max k9-12 Dielectric strength
Ω/km M Ω km nF/km pF/500 m Veff
Value for 0,5 mm 190/ 195,6 200/ 500 100/ 120
0,6 mm 128/ 136 200/ 500 100/ 120
- / 400 800/ 1 000
- / 400 800/ 1 000
CONSTRUCTION DATA Construction 1x2 3x2 10x2 30x2 50x2 80x2 100x2 1x3 3x3 10x3 30x3 50x3 80x3 100x3 1x4 3x4 10x4 30x4 50x4 80x4 100x4 1x5 3x5 10x5 25x5
For constructor 0,5 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 4 4.5 25 12 5.5 40 38 8.0 90 115 13.0 225 192 15.5 340 307 19.5 530 384 21.5 675 6 4.5 30 17 6.5 45 58 9.5 120 173 15.0 315 288 18.5 500 461 22.5 730 576 25.0 915 8 5.0 35 23 7.0 55 76 10.5 155 228 17.0 400 379 21.5 620 607 26.5 970 758 29.5 1215 10 5.5 35 29 8.0 70 95 12.5 195 238 18.0 440
For constructor 0,6 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 6 4.5 25 17 6.0 50 58 9.0 115 173 14.0 285 288 17.0 455 461 21.0 660 576 23.5 830 8 5.0 30 24 6.5 55 82 10.0 170 245 16.0 430 408 20.0 625 653 25.0 975 816 27.5 1195 11 5.0 35 33 7.0 70 108 11.0 205 325 18.0 535 542 22.5 805 868 29.0 1295 1085 31.0 1580 14 6.0 40 41 8.0 80 136 13.5 250 341 20.0 485
99
TI 44,
TI 44 ...E
Installation cable Standard: ZJPTT LNVIII/B10; B11
CONSTRUCTION Conductor: soft annealed copper wire of 0,6 and 0,8 mm diameter for two core and 0,6 for multi core cable. Insulation: PVC compound. Twisting elements: pairs, star quads. Cable core: group or concentric stranded. Core wrapping: thermoplastic tape. For TI 44 E Screen: laminated aluminium foil with a tined copper drain wire longitudinally applied under it for screen continuity Sheath: PVC compound. Sheath colour grey.
APPLICATION
It can use for introducing of overhead lines to buildings and as installation cable in buildings.
ELECTRICAL CHARACTERISTICS Value for Characteristic
100
Unit
Loop resistance, max individual values average values Insulation resistance, min Working capacity, max Coupling capacity, max k1 for 100 % k1 for 98 % e1-e2 Coupling capacity, max k for 100% k for 80% k1 for 100% k1 for 80% k9-12 for 100% k9-12 for 90% Dielectric strength wire/wire wire/screen
Ω/km MΩ km nF/km pF/300 m
pF/500 m
Veff
Two wires 0,6 mm
0,8 mm
More wires 0,6 mm
130 200 130
73.2 200 120
130 126 220 130
800 400 800
800 400 800
800 400 800
-
-
500 300 500 300 300 100
800 -
800 -
800 800
CONSTRUCTION DATA Construction 2x 2x2 5x2 10x2 25x2 50x2 80x2 100x2 5X4 G 10X4 G 25X4 G 40X4 G 50X4 G
For conductor 0,6 mm + E For conductor 0,6 mm For conductor 0,8 mm Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] 11 5.0 30 5.5 35 21 12 12 6.5 45 6.0 40 29 29 8.5 90 8.0 75 58 58 11.5 165 10.5 130 144 144 16.5 325 16.0 300 288 288 22.5 575 21.5 565 461 461 28.0 945 27.0 880 576 576 31.0 1175 30.0 1100 54 54 11.5 140 10.5 130 108 108 13.5 250 14.5 250 271 271 22.5 575 21.5 565 434 434 28.0 895 27.0 880 542 542 31.0 1185 31.0 1100
Cu number
TZ44 ... E, TZ44 ... GE Low-frequency terminal cable Standard: ZJPTT/B8
CONSTRUCTION Conductor: soft annealed copper wire of 0,6 mm diameter. Insulation: PVC compound. Twisting elements: star quads. Cable core: group or concentric stranded. Core wrapping: thermoplastic tape in multi layers. Screen: aluminium foil with a copper drain wire longitudinally applied under it for screen continuity. Sheath: PVC compound. Sheath colour grey.
Cable is intended for connection of terminal continuation and main distribution frame.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual values average values Insulation resistance, min Working capacity, max Coupling capacity, max k1 for 100% k1 for 90% k9-12 for 100% k9-12 for 90% e1-e2 for 100% e1-e2 for 90% Dielectric strength wire/wire wire/screen Direct voltage stability voltage time
Ω/km MΩ km nF/km
pF/100 m
Value for 0,6 mm 130 126 200 100 100 50 100 50 300 150
Veff
500 2000
V h
110±5 10x24
CONSTRUCTION DATA For conductor 0,6 mm Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
25X4 E
271
17.0
440
50X4 E
543
22.5
820
25X4 GE
271
17.0
460
50X4 GE
543
22.5
850
101
TCB Installation telephone cable Standard: ГОСТ 14354-79
CONSTRUCTION Conductor: soft annealed copper wire of 0,4 and 0,5 mm diameter. Insulation: PVC compound. Twisting elements: pairs and triples. Cable core: group or concentric stranded. Core wrapping: thermoplastic tape. Screen: aluminium foil with a copper drain wire longitudinally applied under it for screen continuity. Sheath: PVC compound. Sheath colour grey.
For introducing of overhead lines into buildings and as installation cable in buildings.
APPLICATION
ELECTRICAL CHARACTERISTICS
102
VALUE FOR
Characteristic
unit
0,4 mm
0,5 mm
Conductor resistance, max
Ω/km
148
95
Insulation resistance, min Dielectric strength wire/screen (3 minute)
MΩ km
200
200
Veff
500
500
CONSTRUCTION DATA For conductor 0,4 mm Construction
For conductor 0,5 mm
Cu number
Diameter
Mass
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
[kg/km]
[mm]
[kg/km]
5x2
12,5
7.5
88
19,2
8.0
75
10x2
25,0
9.0
85
38,4
10.0
110
20x2
49,9
11.0
135
76,8
13.0
185
30x2
74,9
13.0
185
115,2
15.0
255
41x2
102,3
15.0
255
157,5
17.5
350
103x2
257,1
22.0
560
395,5
25.5
795
5x3
18,2
8.0
70
28,8
9.0
90
10x3
36,5
9.5
110
57,6
11.0
150
20x3
73,0
13.0
195
115,2
15.0
270
TK33 U Self-supporting low-frequency telephone subscriber cable Standard: ZJPTT LNVIII/B4
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 and 0.8 mm diameter. Insulation: solid PE. Twisting elements: star quads. Cable core: concentric stranded. Core wrapping: thermoplastic tape. Messenger: rope of galvanized steel wire. Sheath: PE. Sheath colour black.
APPLICATION
It is used in local network for subscriber and trunk lines, laid at supports on the ground walls, roofs.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual values average values Insulation resistance, min Mutual capacitance, max for cable with one quad for cable with several quads Coupling capacity, max k1 for 100% k1 for 98% k9-12 for 100%
Value for 0,6 mm
0,8 mm
130 126 10
73.2 72.0 10
52 42
52 42
2700 1350 1000 6
2700 1350 1000 8
120 110
95 85
Ω/km GΩ km nF/km
pF/km
Dielectric strength (2 sec) Projected attenuation at 800 Hz one quad several quads
kV= mN/km
103
CONSTRUCTION DATA Construction
For conductor 0,6 mm Cu number Diameter Mass [kg/km] [mm] [kg/km]
1x4 3X4 5X4 10X4 15X4 20X4 25X4 30X4 40X4
11 33 54 108 163 217 271 325 434
7.0x13.5 10.0x17.5 12.5x20.0 16.5x25.0 19.0x28.5 20.5x31.0 22.5x32.5 25.5x35.5 29.0x40.0
90 180 220 370 520 610 695 810 1045
50X4
542
31.0x42.0
1215
For conductor 0,8 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 19 58 96 193 289 386 482 579
8.0x14.0 13.0x20.0 15.0x24.0 19.0x28.5 22.0x32.0 25.5x35.5 28.0x39.0 30.5x41.5
110 230 350 560 710 890 1100 1240
TK39...M, TK39...GM Filled low-frequency subscriber cable Standard: PTT Vesnik 5/77
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0,6 and 0,8 mm diameter. Insulation: solid PE. Twisting elements: star quads. Cable core: group or concentric stranded. Filling: compound with dropp point over +70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
In local network for subscriber lines, laid in cable ducts or directly into the ground.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual values average values Insulation resistance, min Working capacity, max Coupling capacity, max k1 for 100% k1 for 98% e1-e2 Dielectric strength wire/wire wire/screen Projected attenuation at 800 Hz
Ω/km GΩ km nF/km pF/300 m
Veff/V= mN/km
Value for 0,4 mm
0,6 mm
0,8 mm
300 290 5 38
130 126 5 42
73.2 72.0 5 42
800 400 800
800 400 800
800 400 800
500/700 2000/2800 172
500/700 2000/2800 115
500/700 2000/2800 90
CONSTRUCTION DATA For conductor 0,4 mm
104
Construction
Cu number Diameter
[kg/km] 3x4 5X4 10X4 15X4 20X4 25X4 30X4 35x4 40X4 50X4 75X4 100X4 125X4 150X4 175X4 200X4 250X4 300X4 350X4 400X4 500X4 600x4
24 49 73 98 122 147 169 196 245 367 24 612 734 857 979 1224 1469 1714 1958 2448 2938
[mm] 10.5 12.5 14.5 16.0 17.0 18.5 19.5 20.5 22.0 26.5 10.5 32.5 36.0 38.0 40.5 44.5 48.5 52.0 55.0 61.0 67.0
Mass [kg/km] 100 150 195 240 285 325 355 410 490 700 100 1080 1290 1475 1660 2025 2415 1780 3140 3890 4645
For conductor 0,6 mm Cu number Diameter [kg/km] 33 54 108 163 217 271 325 380 434 542 814 1085 1356 1627 1898 2170 2712 3254
Mass
For conductor 0,8 mm Cu number Diameter
Mass
[mm]
[kg/km]
[kg/km]
[mm]
[kg/km]
11.0 13.0 16.0 18.5 20.5 22.5 24.5 26.0 27.5 30.0 36.0 41.0 45.5 49.0 52.5 56.5 62.0 68.0
115 155 255 345 435 520 620 705 790 955 1380 1785 2205 2605 2995 3420 4195 5010
58 96 193 289 386 482 579 675 772 965 1447 1930
13.0 15.5 19.5 22.5 26.0 28.5 30.5 32.5 34.5 38.0 46.0 52.0
135 230 385 540 705 850 995 1135 1295 1575 2300 2990
TK59...M, TK59...GM Filled low-frequency subscriber cable Standard: ZJPTT LNVIII/B15
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.6 and 0.8 mm diameter. Insulation: foam skin PE. Twisting elements: star quads. Cable core: group or concentric stranded. Filling: compound with dropp point over +70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
In local network for subscriber lines, laid directly into cable ducts or into the ground.
ELECTRICAL CHARACTERISTICS Unit
Characteristic
Value for 0,6 mm
0,4 mm
Loop resistance, max individual value average value Insulation resistance, min Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% e1-e2 Dielectic strenght wire/wire wire/screen Projected attenuation at 800 Hz
Ω/km
0,8 mm
300 290 5
130 126 5
73.2 72.0 5
nF/km
38 -
42 40 38
42 40 38
pF/300 m
800 400 800
800 400 800
800 400 800
500/700 2000/2800 150
500/700 2000/2800 105
500/700 2000/2800 80
GΩ km
Veff/V= mN/km
105
CONSTRUCTION DATA Construction 3x4 5X4 10X4 15X4 20X4 25X4 30X4 40X4 50X4 75X4 100X4 125X4 150X4 175X4 200X4 250X4 300X4 350X4 400X4 500X4
For conductor 0,4 mm For conductor 0,6 mm For conductor 0,8 mm Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km]
Cu number
24 48 72 96 121 145 193 241 362 482 603 723 844 965 1206 1447 1688 1929 2412
12.0 15.0 16.0 18.0 19.5 20.5 23.0 25.0 29.5 33.0 36.5 39.5 42.5 45.0 50.0 54.0 58.5 62.0 68.5
130 190 245 300 365 400 500 630 885 1130 1410 1640 1865 2170 2670 3185 3630 4220 5145
33 54 109 163 217 271 326 434 543 814 1085 1356 1628 1899 2170 2713 3256 3798
12.0 14.0 17.0 19.5 21.5 23.0 25.0 27.0 29.0 31.0 37.0 41.5 46.5 50.0 53.5 57.5 63.5 69.0
135 190 290 405 490 610 700 795 880 1085 1600 2050 2570 3000 3450 4010 4890 5835
58 96 193 289 386 482 579 772 965 1447 1929 2412 2894 3376 3858 4823
13.5 15.5 19.5 22.5 25.5 27.5 29.5 31.5 33.0 37.0 43.5 46,0 50.0 60.5 69.5 76.5
180 260 435 605 790 955 1115 1280 1440 1780 2470 2824 3260 4850 6550 7635
TK59 TP...M, TK59 TP...GM Filled low-frequency subscriber cable with mechanical protection Standard: PTT Vesnik 5/77
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.6 and 0.8 mm diameter. Insulation: foam skin PE. Twisting elements: star quads. Cable core: group or concentric stranded. Filling: compound with dropp point over +70°C. Core wrapping: impregnated paper tape. Inner sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath. Armour: two steel tapes. Sheath: polyethylene.
APPLICATION
In local network for subscriber lines, laid directly into the ground.
ELECTRICAL CHARACTERISTICS Unit
Characteristic
106
0,4 mm
Loop resistance, max individual value average value Insulation resistance, min Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% e1-e2 Dielectic strenght wire/wire wire/screen Projected attenuation at 800 Hz
Ω/km
Value for 0,6 mm
0,8 mm
300 290 5
130 126 5
73.2 72.0 5
nF/km
38 -
42 40 38
42 40 38
pF/300 m
800 400 800
800 400 800
800 400 800
500/700 2000/2800 150
500/700 2000/2800 105
500/700 2000/2800 80
GΩ km
Veff/V= mN/km
CONSTRUCTION DATA Construction 3x4 5X4 10X4 15X4 20X4 25X4 30X4 40X4 50X4 75X4 100X4 125X4 150X4 175X4 200X4 250X4 300X4 350X4 400X4 500X4
For conductor 0,4 mm For conductor 0,6 mm For conductor 0,8 mm Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] 33 58 18.5 560 20.0 630 24 54 96 16.0 505 20.5 600 23.0 790 48 109 193 18.0 640 24.5 820 27.0 1070 72 163 289 19.5 720 27.0 1000 29.5 1395 96 217 386 20.5 850 29.0 1140 33.5 1695 121 271 482 23.0 960 30.5 1200 35.0 1800 145 326 579 25.0 1025 32.5 1440 37.5 2180 193 434 772 29.5 1210 37.0 1890 41.0 2695 241 543 965 33.0 1370 39.0 2040 46.0 2930 362 814 1447 36.5 1790 46.0 2760 53.0 4410 482 1085 41.0 2130 50.5 3340 603 1356 45.5 2560 56.0 4080 723 1628 48.5 2920 59.5 4590 844 1899 51.5 3190 65.0 6470 965 2170 54.0 3560 68.0 6620 59.5 4270 76.0 7950 1206 2713 64.0 5580 81.0 9230 1447 3256 1688 3798 58.5 3630 69.0 5835 1929 62.0 4220 68.5 5145 2412
Cu number
TK59...MR , TK59...GMR Filled low-frequency subscriber cable with improved reduction factor Standard: PSN
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.6 and 0.8 mm diameter. Insulation: foam skin PE. Twisting elements: star quads. Cable core: group or concentric stranded. Filling: compound with dropp point over +70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
Screen: aluminium wires. Outher sheath: PE.
Sheath colour black.
APPLICATION
In local network for subscriber lines where the inductive influence of power lines is to be expected. It is laid into the ground or cable ducts.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max individual value average value Insulation resistance, min Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% e1-e2 Dielectic strenght wire/wire wire/screen Projected attenuation at 800 Hz
Value for 0,4 mm
0,6 mm
0,8 mm
300 290 5
130 126 5
73.2 72.0 5
nF/km
38 -
42 40 38
42 40 38
pF/300 m
800 400 800
800 400 800
800 400 800
500/700 2000/2800 150
500/700 2000/2800 105
500/700 2000/2800 80
Ω/km GΩ km
Veff/V= mN/km
CONSTRUCTION DATA Construction 3x4 5X4 10X4 15X4 20X4 25X4 30X4 40X4 50X4 75X4 100X4 125X4 150X4 175X4 200X4 250X4
For conductor 0,4 mm For conductor 0,6 mm For conductor 0,8 mm Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] 17.5 390 33 58 13.5 180 18.5 330 20.0 450 24 54 96 15.5 260 22.0 465 23.0 590 48 109 193 19.5 435 23.0 540 26.5 790 72 163 289 22.5 605 25.5 665 28.5 950 96 217 386 25.5 790 27.5 755 30.5 1145 121 271 482 27.5 955 28.5 855 33.0 1295 145 326 579 29.5 1115 29.5 915 36.0 1505 193 434 772 31.5 1280 32.0 1050 38.0 1620 241 543 965 33.0 1440 34.0 1230 40.0 1950 362 814 1447 37.0 1780 39.5 1615 47.5 2720 482 1085 1929 43.5 2470 43.5 1890 53.0 3470 603 1356 48.0 2540 59.0 4265 723 1628 53.5 3060 62.5 4835 844 1899 55.0 3340 68.5 5590 965 2170 58.5 3840 70.5 6180 1206 2713
Cu number
107
ТПП Low-frequency telephone subscriber cable Standard: ГОСТ 51311-99
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.5 and 0.7 mm diameter. Insulation: solid PE. Twisting elements: pairs. Cable core: group or concentric stranded (up to 100 pairs). Core wrapping: thermoplastic tapes in several layers. Screen: aluminum tape wrapping with a copper drain wire applied longitudinally under it. Sheath: PE. Sheath colour black.
APPLICATION
In local network for subscriber lines, laid into the cable ducts.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Conductor resistance, max Insulation resistance, min 100% 80% Mutual capacitance, max Dielectic strenght wire/wire wire/screen
Ω/km GΩ km nF/km Veff
0,4 mm 139+9
Value for 0,5 mm 90+6
0,7 mm 45+3
6.5 8 45+5
6.5 8 45+5
6.5 8 45+5
1000 2000
1000 2000
1000 2000
CONSTRUCTION DATA
108
For conductor 0,4 mm Mass [kg/km] [mm] [kg/km]
Construction Cu number Diameter
5x2 10x2 20x2 30x2 50x2 100x2 150x2 200x2 300x2 400x2 500x2 600x2 700x2 800x2 900x2 1000x2
24 48 72 121 241 362 482 723 965 1206 1447 1688 1929 2170 2412
9.5 11.5 13.0 16.0 21.5 24.5 28.5 33.5 38.5 42.0 45.0 49.0 52.0 54.5 57.0
80 120 165 255 465 650 865 1220 1620 1965 2305 2715 3055 3390 3725
For conductor 0,5 mm For conductor 0,7 mm Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km]
Cu number Diameter
19 38 75 113 188 377 565 754 1130 1507 1884
9.0 10.5 13.0 15.5 18.5 25.0 30.0 34.0 41.0 46.0 51.5
70 105 165 240 355 670 985 1260 1850 2385 2980
96 193 289 482 965 1447 1929 2894
12.5 16.0 18.5 23.5 32.0 38.0 43.0 52.0
160 285 400 645 1215 1790 2305 3390
TPP EP Low-frequency telephone subscriber cable Standard: ГОСТ 51311-99
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.5 and 0.7 mm diameter. Insulation: solid PE. Twisting elements: pairs. Cable core: group or concentrated stranded (up to 100 pairs). Core wrapping: thermoplastic tapes in several layers. Sheath: aluminum tape covered on both sides with a layer of ethylene copolymer and PE sheath. Sheath colour black.
APPLICATION
In local network for subscriber lines, laid into the cable ducts.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Conductor resistance, max Insulation resistance, min 100% 80% Mutual capacitance, max
Value for 0,4 mm
0,5 mm
0,7 mm
Ω/km
139+9
90+6
45+3
GΩ km
6.5 8
6.5 8
6.5 8
nF/km
45+5
45+5
45+5
Veff
1000 2000
1000 2000
1000 2000
Dielectric strength wire/wire wire/screen
CONSTRUCTION DATA
109
For conductor 0,4 mm Construction
Cu number Diameter
[kg/km]
5x2 10x2 20x2 30x2 50x2 100x2 150x2 200x2 300x2 400x2 500x2 600x2 700x2 800x2 900x2 1000x2
24 48 72 120 241 361 482 723 964 1205 1446 1687 1928 2169 2410
[mm]
9.5 11.5 13.0 16.0 21.5 24.5 28.5 33.5 38.5 42.0 45.0 49.0 52.0 54.5 57.0
Mass [kg/km]
80 120 165 255 465 650 865 1220 1620 1965 2305 2715 3055 3390 3725
For conductor 0,5 mm Cu number Diameter
Mass
[kg/km]
[mm]
[kg/km]
19 38 77 115 192 384 576 768 1152 1536 1920
9.0 10.5 13.0 15.5 18.5 25.0 30.0 34.0 41.0 46.0 51.5
70 105 165 240 355 670 985 1260 1850 2385 2980
For conductor 0,7 mm Cu number Diameter
Mass
[kg/km]
[mm]
[kg/km]
74 148 222 370 739 1109 1478 2218
12.5 16.0 18.5 23.5 32.0 38.0 43.0 52.0
160 285 400 645 1215 1790 2305 3390
A-02Y(L)2Y Low-frequency telephone subscriber cable Standard: VDE 0816/88
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 mm and 0.8 mm diameter. Insulation: foam-skin PE. Twisting elements: star quads. Cable core: group stranded. Core wrapping: thermoplastic tapes in several layers. Sheath: aluminum tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
In local network for subscriber and trunk lines, laid in cable ducts.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max
Value for
Ω/km
0,6 mm 130
0,8 mm 73.2
Insulation resistance, min
GΩ km
5
5
Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% k9-12 100% k9-12 98% Dielectric strength wire/wire wire/screen Operating voltage, peak value
nF/km 42 40 38
42 40 38
800 400 300 100
800 400 300 100
2000 150
500 2000 225
pF/300 m
Veff V
110 CONSTRUCTION DATA Konstrukcija 6x2 10x2 20x2 30x2 40x2 50x2 70x2 100x2 120x2 150x2 200x2 250x2 300x2 350x2 400x2 500x2 600x2 700x2
For conductor 0,6 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 33 10.5 90 54 12.0 130 109 15.0 210 163 17.5 290 217 19.5 365 271 21.0 440 380 24.5 595 543 28.0 810 651 30.0 955 814 33.0 1165 1085 37.5 1530 1356 41.5 1880 1628 45.5 2280 1899 49.0 2615 2170 51.5 2960 2713 58.0 3705 3256 62.5 4385 68.0 5140 3798
For conductor 0,8 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 58 12.0 130 96 14.0 190 193 18.0 320 289 21.0 450 386 23.5 580 482 26.0 710 675 29.5 960 965 34.5 1340 1158 37.5 1580 1447 41.5 1940 1929 47.5 2590 2412 52.5 3180 2894 57.5 3830 3376 61.5 4650 3858 65.5 5010 4823 73.0 6260
A-2Y(L)2Y ...St III Bd Low-frequency telephone subscriber cable Standard: VDE 0816/88
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 mm and 0.8 mm diameter. Insulation: solid PE. Twisting elements: star quads. Cable core: group stranded. Core wrapping: thermoplastic tapes in several layers. Sheath: aluminum tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
In local network for subscriber and trunk lines, laid in cable ducts.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Insulation resistance, min Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% k9-12 100% k9-12 98% Dielectric strength wire/wire wire/screen Operating voltage, peak value
Ω/km GΩ km
0,4 mm 300 5
Value for 0,6 mm 130 5
0,8 mm 73.2 5
50 48 -
52 50 48
55 53 50
800 400 300 100
800 400 300 100
800 400 300 100
Veff
2000
500 2000
500 2000
V
150
225
225
nF/km
pF/300 m
CONSTRUCTION DATA Construction 6x2 10x2 20x2 30x2 40x2 50x2 70x2 100x2 120x2 150x2 200x2 250x2 300x2 350x2 400x2 500x2 600x2 700x2 800x2 1000x2 1200x2
For conductor 0,4 mm For conductor 0,6 mm For conductor 0,8 mm Cu number Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] 14 8.5 70 33 10.0 100 58 11.5 140 24 10.0 90 54 11.5 140 96 13.5 200 48 11.5 135 109 14.5 235 193 17.0 340 72 13.0 180 163 16.5 305 289 19.5 470 96 14.5 220 217 18.0 385 386 21.5 600 121 15.5 230 271 19.5 460 482 23.5 725 169 17.5 335 380 22.5 605 675 27.5 990 241 20.0 445 543 26.0 845 965 31.5 1360 289 21.5 515 651 28.0 995 1158 34.5 1630 362 23.5 620 814 30.5 1205 1447 38.0 1990 482 26.5 815 1085 35.0 1580 1929 43.0 2590 603 29.0 985 1356 38.5 1935 2412 48.0 3250 723 31.5 1155 1628 41.5 2280 2894 52.0 3840 33.5 1330 45.5 2680 56.5 4500 844 1899 3376 965 36.0 1510 2170 48.0 3035 3858 60.0 5095 1206 39.5 1845 2713 53.0 3730 1447 42.5 2180 3256 58.0 4480 1688 46.5 2565 3798 62.0 5170 1929 49.0 2895 2412 54.0 3550 2894 59.5 4250
111
A-2YF(L)2Y ...St III Bd Low-frequency filled subscriber cable Standard: VDE 0816/88
CONSTRUCTION Conductor: soft annealed copper wire of 0,4; 0.6 and 0.8 mm diameter. Insulation: solid PE. Twisting elements: star quads. Cable core: group stranded. Filling: compound with dripping point above +70°C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
In local network for subscriber and trunk lines, laid in cable ducts or directly into the ground.
ELECTRICAL CHARACTERISTICS Unit
Characteristic Loop resistance, max Insulation resistance, min Mutual capacitance for 100% for 95% for 80% Capacitance unbalance, max k1 for 100% k1 for 98% k9-12 100% k9-12 98% Dielectric strength wire/wire wire/screen Operating voltage, peak value
112
Ω/km GΩ km nF/km
pF/300 m
Veff V
0,4 mm 300 5
Value for 0,6 mm 130 5
0,8 mm 73.2 5
50 48 -
52 50 48
55 53 50
800 400 300 100
800 400 300 100
800 400 300 100
2000 150
500 2000 225
500 2000 225
CONSTRUCTION DATA Construction 6x2 10x2 20x2 30x2 40x2 50x2 70x2 100x2 120x2 150x2 200x2 250x2 300x2 350x2 400x2 500x2 600x2 700x2 800x2 1000x2 1200x2
For conductor 0,4 mm For conductor 0,6 mm For conductor 0,8 mm Diameter Mass Cu number Diameter Mass Cu number Diameter Mass [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] [kg/km] [mm] [kg/km] 33 12.0 135 58 13.5 190 24 11.5 150 54 14.0 185 96 16.0 270 48 13.5 180 109 17.0 300 193 20.0 450 72 15.5 240 163 19.5 410 289 23.0 630 96 17.0 290 217 21.5 530 386 26.5 820 121 18.0 360 271 23.5 620 482 28.5 990 169 20.5 450 380 27.0 870 675 32.5 1330 241 23.0 615 543 31.0 1155 965 38.5 1760 289 25.0 695 651 33.5 1345 1158 41.5 2180 362 27.5 845 814 37.0 1670 1447 46.0 2730 482 31.0 1085 1085 42.0 2165 1929 52.0 3560 603 33.5 1310 1356 47.0 2695 2412 58.0 4430 723 36.5 1565 1628 50.5 3185 2894 63.0 5260 39.0 1795 54.0 3660 68.0 6140 844 1899 3376 965 41.5 1995 2170 58.0 4180 3858 72.5 6950 1206 45.5 2475 2713 63.0 5180 1447 50.0 2985 3256 70.0 6195 1688 53.5 3435 3798 75.0 7160 1929 57.0 3940 2412 63.0 4840 69.0 5790 2894
Cu number
TD 39 U-P, TD 59 U-P Self-supporting low-frequency cable network group Standard: PTT Vesnik 14/77
CONSTRUCTION Conductor: soft annealed copper wire of 0.8 and 0.9 mm diameter. Insulation: solid (39) or foam skin PE (59). Twisting elements: star quad. Cable core: concentric stranded. Core wrapping: thermoplastic tapes in several layers. Inner sheath: PE. Messenger: rope of galvanized steel wires. Outer sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
Cable is used in network group for trunk lines. It is installed on poles.
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Resistance difference, max Insulation resistance, min Mutual capacitance Capacitance unbalance, max k1 k9-12 e1-2 Dielectic strenght wire/wire wire/screen Projected attenuation at 800 Hz
Ω/km
Value for 0,8 mm 73.2 0.92 10 34+12 %
0,9 mm 56.6 0.92 10 34+12 %
pF/300 m
250 250 650
250 250 650
Veff
2000 3000 75
2000 3000 65
GΩ km nF/km
mN/km
113
CONSTRUCTION DATA FOR TD 39 U-P Construction 3x4 5x4 7x4 10x4 15x4
For conductor 0,8 mm Cu number Diameter Mass [kg/km] 58 96 135 193 290
[mm] 14.0x22.5 16.5x24.5 18.5x28.0 21.0x30.5 24.5x36.0
[kg/km] 270 360 465 575 810
For conductor 0,9 mm Cu number Diameter Mass [kg/km]
[mm]
[kg/km]
122 171 244
18.0x28.0 20.5x30.5 23.5x34.5
450 550 735
CONSTRUCTION DATA FOR TD 59 U-P
Construction 3x4 5x4 7x4 10x4 15x4
For conductor 0,8 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 58 96 135 193 290
12.5x21.0 14.5x23.5 16.5x26.0 18.5x28.0 21.0x32.0
245 320 415 510 705
For conductor 0,9 mm Cu number Diameter Mass [kg/km] [mm] [kg/km] 122 171 244
16.0x26.0 17.5x27.5 20.0x31.0
400 480 645
TD 59 ... M, TD 59 ... GM Low-frequency filled connecting cable Standard: PTT Vesnik 5/80
CONSTRUCTION Conductor: soft annealed copper wire of 0,9 and 1,2 mm diameter. Insulation: foam-skin PE. Twisting elements: star quads. Cable core: group or concentric stranded. Filling: compound with drop point above +70 0C. Core wrapping: impregnated paper tape. Sheath: aluminium tape covered on both sides with a layer of ethylene copolymer and PE sheath.
APPLICATION
For the connection of individual exchanges in decentralized local networks and network group.
ELECTRICAL CHARACTERISTICS Unit
Characteristic
114
Ω/km Ω/426m GΩ km nF/km
Loop resistance, max Resistance difference, max Insulation resistance, min Mutual capacitance Capacitance unbalance, max k1 k2-3 k4-8 k9-12 e1-e2 e3 Dielectric strength wire/wire wire/screen Projected attenuation at 800 Hz
pF/426 m
Veff/V mN/km
Value for 0,9 mm 56.6 0.6 10 34±5%
1,2 mm 31.8 0.6 10 35 ±5%
100 550 100 100 550 1100
100 550 100 100 550 1100
500/700 2000/2800 65
500/700 2000/2800 52
CONSTRUCTION DATA Construction 3X4 5X4 7X4 12X4 19X4 27X4 35X4 50X4 5X4 15X4 20X4 25X4 35X4 50X4 75X4 100X4
G G G G G G G G
Cu number [kg/km]
For conductor 0,9 mm Diameter Mass [mm] [kg/km]
75 125 175 300 474 674 874 1248
14.5 16.5 17.5 21.5 26.0 30.0 33.0 39.0
210 285 355 560 840 1140 1435 2005
125 374 499 624 874 1248 1872 2496
16.5 24.0 26.5 29.0 33.0 39.0 47.0 53.0
285 685 880 1065 1435 2005 2950 3840
For conductor 1,2 [mm] Cu number Diameter Mass [kg/km] [mm] [kg/km] 131 218 306 524
17.0 20.0 22.0 27.5
315 460 570 940
ТБ
ТЗБ
Low-frequency subscriber cable with paper insulation Standard: PSN
CONSTRUCTION Conductor: soft annealed copper wire of 0,5 and 0,64 mm diameter. Insulation: wrapped with paper tape. Twisting elements: pairs. Cable core: group or concentric stranded. Core wrapping: paper tapes in several layers. Sheath: seamless lead pipe. Armour: impregnated paper tapes, bitumen, steel tapes, bitumen, impregnated gunny, chalk, talc.
APPLICATION
Conductor: soft annealed copper wire of 0,9 and 1,2 mm diameter. Insulation: wrapped with paper cordell and paper tape. Twisting elements: star quads wrapped with cotton threads. Cable core: concentric stranded. Core wrapping: paper tapes in several layers. Sheath: seamless lead pipe. Armour: impregnated paper tapes, bitumen, steel tapes, bitumen, impregnated gunny, chalk, talc.
The local network for subscriber lines (TБ) and the network group (TЗБ). The cable is laid in cable drains or directly into the ground when the cable is subjected to pressure or traction forces, and do not expect any increased electro-magnetic influence.
ELECTRICAL CHARACTERISTICS FOR ТБ Characteristic
Unit
Conductor resistance, max
Value for 0,5 mm
0,64 mm
Ω/km
95
58
Mutual capacitance, max
nF/km
52
50
Insulation resistance, min
GΩ km
8
8
VDS
750 750
750 750
Dielectric strength wire/wire (2 minute) wire/screen (2 minute)
ELECTRICAL CHARACTERISTICS FOR ТЗБ Characteristic
Unit
Conductor resistance, max
Value for 0,9 mm
1,2 mm
Ω/km
28,3
15,9
Mutual capacitance, max
nF/km
38
38
Insulation resistance, min
GΩ km
8
8
Veff
700 1800
1000 1800
Dielectric strength wire/wire (2 minute) wire/screen (2 minute)
115
ТГ
ТЗГ
Low-frequency subscriber cable with paper insulation Standard: PSN
CONSTRUCTION Conductor: soft annealed copper wire of 0,5 and 0,64 mm diameter. Insulation: wrapped with paper tape. Twisting elements: pairs. Cable core: group or concentric stranded. Core wrapping: paper tapes in several layers. Sheath: seamless lead pipe.
APPLICATION
Conductor: soft annealed copper wire of 0,9 and 1,2 mm diameter. Insulation: wrapped with paper cordell and paper tape. Twisting elements: star quads wrapped with cotton threads. Cable core: concentric stranded. Core wrapping: paper tapes in several layers. Sheath: seamless lead pipe.
The local network for subscriber lines (TГ) and the network group (ТЗГ) will take place in cable sewers, pipes or on walls in areas that do not adversely affect the lead sheath of special and where there is no electromagnetic interference.
ELECTRICAL CHARACTERISTICS FOR ТГ Characteristic
116
Unit
Value for 0,5 mm
0,64 mm
Conductor resistance, max
Ω/km
95
58
Mutual capacitance, max
nF/km
52
50
Insulation resistance, min
GΩ km
8
8
VDS
750 750
750 750
Dielectric strength wire/wire (2 minute) wire/screen (2 minute)
ELECTRICAL CHARACTERISTICS FOR ТЗГ Characteristic
Unit
Conductor resistance, max
Value for 0,9 mm
1,2 mm
Ω/km
28,3
15,9
Mutual capacitance, max
nF/km
38
38
Insulation resistance, min
GΩ km
8
8
Veff
700 1800
1000 1800
Dielectric strength wire/wire (2 minute) wire/screen (2 minute)
S-YY Signal cable Standard: VDE 0813
CONSTRUCTION Conductor: soft annealed copper wire of 0,5; 0,6 and 1,0 mm diameter. Insulation: PVC compound. Twisting elements: cores. Cable core: concentric stranded. Core wrapping: thermoplastic tape. Sheath: PVC compound. Sheath colour grey.
Cable is intended for transmission of low-frequency commands in signalling equipment.
APPLICATION
ELECTRICAL CHARACTERISTICS Value dor
Characteristic
Unit
0,5 mm
0,6 mm
1,0 mm
Conductor resistance, max
Ω/km
96
65
23.4
Insulation resistance, min
MΩ km
100
100
100
2000
2500
2500
250
250
400
0.1
0.1
0.1
Dielectric strength wire/wire
Veff
Operating voltage, max
Veff
Loss meter tangent
CONSTRUCTION DATA For conductor 0,5 mm Construction Cu number Diameter [kg/km]
[mm]
Mass
For conductor 0,6 mm Cu number Diameter
[kg/km] [kg/km]
[mm]
Mass
For conductor 1,0 mm Cu number Diameter
[kg/km] [kg/km]
[mm]
Mass [kg/km]
10x1
19,2
6.5
50
28,8
7.5
70
76,8
10.0
140
20x1
38,4
8.0
85
57,6
9.5
120
153,6
13.0
265
30x1
57,6
9.5
120
86,4
11.5
170
230,4
15.5
380
40x1
76,8
10.5
150
115,2
13.0
230
307,2
17.5
495
60x1
115,2
12.5
225
172,8
15.5
330
460,8
21.0
725
230,4
17.5
425
80x1
117
S-Y(St)Y... Screened signal cable Standard: VDE 0813
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 mm diameter. Insulation: PVC compound. Twisting elements: pairs, triples. Cable core: group stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire longitudinally applied under it. Sheath: PVC compound. Sheath colour grey.
It can use for transmission of low-frequency commands in signalling equipment.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Insulation resistance, min 20 °C 50 °C Mutual capacitance, max Capacitance unbalance, max k e Dielectric strength wire/wire Operating voltage, max Loss meter tangent
Ω/km MΩ km nF/km pF/100m Veff Veff
Value for 0,6 mm 130 100 1 120 50 150* 800 800 200 0.1
* Permissible exceeding for 10 % of value, and min. One is 300 pF/100 m
118
CONSTRUCTION DATA For conductor 0,6 mm Construction
Cu number
Diameter
Mass
1x2x0,6 3x2x0,6 4x2x0,6 5x2x0,6 6x2x0,6 10x2x0,6 11x2x0,6 12x2x0,6 15x2x0,6 16x2x0,6
[kg/km] 6 17 23 29 35 58 63 69 86 92
[mm] 4.5 5.5 6.0 6.5 7.0 8.5 8.7 9.0 9.8 10.0
[kg/km] 25 40 50 60 65 100 105 110 140 145
5x3x0.6 10x3x0.6 11x3x0.6 15x3x0.6 18x3x0.6 20x3x0.6 21x3x0.6 24x3x0.6 25x3x0.6 28x3x0.6
41 82 90 122 147 163 171 196 204 228
7.5 10.0 10.5 11.5 12.5 13.0 13.5 14.0 14.5 15.0
80 140 150 195 235 260 270 305 315 350
TO SM O3 nxIIx0,4x3,5xCMAN Optical cable without metal elements Standard: ZJPTT
CONSTRUCTION Cable core: Optical fibre with primary protection. Secondary fibre protection tubes. Tubes and cable core space filling compound. Central messenger, with or without PE layer. Layer insulation from bubbling dust tape. Peripheral messenger: aramid fibre layer over the core. Sheath: PE.
APPLICATION
Non metal optical cables are specially designed for application at places along the power lines, in the areas with frequent discharging and near power industry division units, for they are totally resistant to all types of electromagnetic influences and atmosphere discharges. They are laid, as a rule, by inserting into telephone tubes.
TECHNICAL DATA Optical characteristics: Mode area diameter/coating diameter/primary protection (μm) Attenuation: at 1300 nm (dB/km) at 1550 nm (dB/km) Dispersion: at 1300 nm (ps/(nmxkm)) ati 1550 nm (ps/(nmxkm)) Tensile strength, max (N)
Construction TO TO TO TO TO TO TO TO TO TO
SM SM SM SM SM SM SM SM SM SM
03 1x6xIIx0,4x3,5xCMAN 03 2x6xIIx0,4x3,5xCMAN 03 3x6xIIx0,4x3,5xCMAN 03 4x6xIIx0,4x3,5xCMAN 03 5x6xIIx0,4x3,5xCMAN 03 6x6xIIx0,4x3,5xCMAN 03 8x6xIIx0,4x3,5xCMAN 03 6x12xIIx0,4x3,5xCMAN 03 8x12xIIx0,4x3,5xCMAN 03 12x12xIIx0,4x3,5xCMAN
9,2/125/250 0,40 0,25 3,50 18,00 1500
Diameter [mm] 11,3 11,3 11,3 11,3 11,3 11,3 12,6 13,8 15,6 19,0
Mass [kg/km] 99,3 99,3 99,3 99,3 99,3 99,3 121,8 150,7 188,0 279,0
Permissible temperatures: - before and after installation from -20 0C to +50 0C - at laying from 0 0C to +40 0C Marking the cable TO SM ab n x T x A x B x S TO – basic label for telecommunication cable with optical fibres SM – additional label for cable with monomode fibres ab – armour and insulation label (03 – PE sheath; 04 – PVC sheath) n – number of fibres in the cable T – specified optical window (I – 850 nm; II – 1300 nm; III – 1550 nm) A – cable attenuation in dB/km B – coefficient dispersion in ps/(nmxkm) S – additional label of one of more letters C – tube secondary protection; M – filled cable; A – aramid fibre cable; N – non metal cable
119
TO SM 19 nxIIx0,4x3,5xCMA Optical cable with metal elements Standard: ZJPTT
CONSTRUCTION Cable core: Optical fibre with primary protection. Secondary fibre protection tubes. Tubes and cable core space filling compound. Central messenger, with or without PE layer. Layer insulation from bubbling dust tape. Peripheral messenger: aramid fibre layer over the core. Inner sheath: PE. Armour: galvanized steel tapes. Sheath: PE.
APPLICATION TECHNICAL DATA
Optical cables can be used in local telephone network as joit cables, in inter local telephone networks as inter local cables and for operation of incoming line transmission systems. The installation can be done directly into the ground or by inserting into the telephone tubes.
Optical characteristics: Mode area diameter/coating diameter/primary protection (μm) Attenuation: at 1300 nm (dB/km) at 1550 nm (dB/km) Dispersion: at 1300 nm (ps/(nmxkm)) at 1550 nm (ps/(nmxkm)) Tensile strength, max (N)
Construction
120
TO TO TO TO TO TO TO TO
SM SM SM SM SM SM SM SM
19 19 19 19 19 19 19 19
1x6xIIx0,4x3,5xCMAN 2x6xIIx0,4x3,5xCMAN 3x6xIIx0,4x3,5xCMAN 4x6xIIx0,4x3,5xCMAN 6x6xIIx0,4x3,5xCMAN 8x6xIIx0,4x3,5xCMAN 10x6xIIx0,4x3,5xCMAN 12x6xIIx0,4x3,5xCMAN
9,2/125/250 0,40 0,25 3,50 18,00 1500
Diameter [mm] 18,3 18,3 18,3 18,3 18,3 19,4 19,4 21,9
Mass [kg/km] 380,0 380,0 380,0 380,0 380,0 440,0 440,0 532,0
Permissible temperatures: - before and after installation from -20 0C to +50 0C - at laying from 0 0C to +40 0C Marking the cable TO SM ab n x T x A x B x S TO – basic label for telecommunication cable with optical fibres SM – additional label for cable with monomode fibres ab – armour and insulation label (03 – PE sheath; 04 – PVC sheath) n – number of fibres in the cable T – specified optical window (I – 850 nm; II – 1300 nm; III – 1550 nm) A – cable attenuation in dB/km B – coefficient dispersion in ps/(nmxkm) S – additional label of one of more letters C – tube secondary protection; M – filled cable; A – aramid fibre cable; N – non metal cable
121
ELECTRONIC CABLES Y YV 6Y 7Y LiY, LiY-T
123 124 125 126 127
Li6Y Li7Y LiYY, So-LiYY LiYCY, So-LiYC Y LiYCY, So-LiYC Y
128 129 130 131 132
Y Installation insulated conductor Standard: VDE 0815 Nominal voltage: 600 V Test voltage: 2000 V
CONSTRUCTION Conductor: tinned copper wire. Insulation: PVC compound. Colour: DIN 47100
APPLICATION
As installation insulated conductor in dry and damp operating area.
TECHNICAL DATA Construction nxd
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
Construction nxd
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
1x0.6
0.28
1.4
4.5
1x0.8
0.51
1.7
7.5
2x0.6
0.57
2.8
9.0
2x0.8
1.02
3.4
14.5
3x0.6
0.85
3.1
13.5
3x0.8
1.53
3.7
21.5
4x0.6
1.13
3.4
18.0
4x0.8
2.04
4.1
29.0
n – number of the elements d – nominal cross section of the conductor Permissible environment temperature: - at laying from -5 °C up to +50 °C - before and after laying from -30 °C up to +70 °C
123
YV; YV-T Interconnecting insulated conductor Standard: VDE 0881
CONSTRUCTION Conductor: tinned copper wire. Insulation: PVC compound. Colour: DIN 47100
Equipment wires YV type, are intended for internal connections in radio and TV devices, telecommunication devices, and for mutual connecting of telecommunication devices.
APPLICATION
Equipment wires YV-T type, are intended for internal connections at electric devices that are demanding high quality materials: good merging characteristics during soldering, minimal contraction of insulation and good burning resistance.
TECHNICAL DATA Construction nxd
124
AWG
Cu number
Diameter
Nominal voltage
Test voltage
Mass
[kg/km]
[mm]
[V]
[V]
[kg/km]
1x0,25
30
0,5
0,75
450
1500
1,0
1x0,32
28
0,8
0,80
450
1500
1,4
1x0,4
26
1,2
0,90
450
1500
1,9
1x0,5
24
1,9
1,00
450
1500
2,6
1x0,62
22
2,9
1,20
450
1500
3,7
1x0,8
20
4,8
1,30
450
1500
5,7
1x1,0
18
7,5
1,80
1500
3000
9,5
1x1,3
16
12,7
2,10
1500
3000
14,8
1x1,6
14
19,3
2,40
1500
3000
21,4
n – number of elements d – nominal cross section of the conductor Permissible environment temperature: - YV from -20 °C up to +70 °C - YV-T from -20 °C up to +105 °C
6Y Equipment wire FEP insulated Standard: VDE 0881
CONSTRUCTION Conductor: tin or silver-plated copper wire. Insulation: extruded FEP. Colour: white, brown, green, yellow, grey, pink, blue, red, black, violet
Equipment wire with insulation of FEP mass, type 6Y, are intended for wiring of all kinds of electronic and medical devices, etc.
APPLICATION
TECHNICAL DATA
Construction nxd
AWG
Cu number
Nominal voltage
Test voltage
Diameter
Mass
[kg/km]
[V]
[V]
[mm]
[kg/km]
1x0,25
30
0,5
375
1500
0,55
0,8
1x0,25
30
0,5
900
2500
0,75
1,1
1x0,32
28
0,8
375
1500
0,60
1,1
1x0,32
28
0,8
900
2500
0,80
1,4
1x0,4
26
1,2
375
1500
0,70
1,6
1x0,4
26
1,2
900
2500
0,90
1,9
1x0,5
24
1,9
375
1500
0,80
2,3
1x0,5
24
1,9
900
2500
1,00
2,6
1x1,62
22
2,9
375
1500
0,95
3,5
1x0,62
22
2,9
900
2500
1,20
4,5
1x0,8
20
4,8
375
1500
1,10
5,2
1x0,8
20
4,8
900
2500
1,30
5,8
1x1,0
18
7,5
900
2500
1,50
8,6
1x1,3
16
12,7
900
2500
1,80
13,9
1x1,6
14
19,3
900
2500
2,10
20,2
n – number of the elements d – nominal cross section of the conductor Permissible environment temperature: from -55 °C up to +200 °C
125
7Y Equipment wire ETFE insulated Standard: VDE 0881
CONSTRUCTION Conductor: tin or silver-plated copper wire. Insulation: extruded ETFE. Colour: white, green, yellow, grey, pink, blue, red, black, violet
Equipment wires with insulation of ETFE mass, 7Y type are intended for automatic or semi-automatic panel connection in computer techniques, in telephone centrals and aero industry for wiring of all devices that need high level of mechanical resistance.
APPLICATION
TECHNICAL DATA Construction nxd
126
AWG
Cu number [kg/km]
Nominal voltage
Test voltage
Diameter
Mass [kg/km]
[V]
[V]
[mm]
1x0,25
30
0,5
375
1500
0,55
0,7
1x0,4
26
1,2
375
1500
0,70
1,5
1x0,4
26
1,2
900
2500
0,90
1,9
1x0,5
24
1,9
375
1500
0,80
2,2
1x0,5
24
1,9
900
2500
1,00
2,6
1x0,62
22
2,9
375
1500
0,95
3,3
1x0,62
22
2,9
900
2500
1,20
3,7
1x0,8
20
4,8
375
1500
1,10
5,1
1x0,8
20
4,8
900
2500
1,30
5,6
1x1,0
18
7,5
900
2500
1,50
8,3
1x1,3
16
12,7
900
2500
1,80
13,4
1x1,6
14
19,3
900
2500
2,10
19,9
n – number of the elements d – nominal cross section of the conductor Permissible environment temperature: from -55 °C up to +150°C.
LiY; LifY;LiY-T;LifY-T Flexible interconnecting PVC insulated conductor Standard: VDE 0812
CONSTRUCTION Conductor: stranded tinned copper wire. Insulation: PVC compound. Colour: DIN 47100
Equipment wires with insulation of PVC mass, LiY type, are intended for internal connections in telecommunication, measuring, signal or similar type of devices.
APPLICATION
Flexible equipment wires with insulation of PVC mass, LifY type, are intended for external connections at small transformers, mobile units and for making connections that are demanding small mechanical voltage, simply merging by soldering and high flexibility. Equipment wires with insulation of PVC mass, LiY-T and LifY-T type, are intended for internal connections at electric devices that are demanding top quality materials: good merging characteristics during soldering, minimal contraction of insulation, good burning resistance.
Technical data Construction nxd
AWG
Cu number
Nominal voltage
Test voltage
Diameter
Mass
[kg/km]
[V]
[V]
[mm]
[kg/km]
1x0,055
30
0,5
450
1500
0,80
1,1
1x0,079
28
0,8
450
1500
0,90
1,4
1x0,12
26
1,2
450
1500
1,00
1,9
1x0,22
24
2,1
450
1500
1,10
2,9
1x0,25
-
2,4
900
2500
1,30
3,5
1x0,22
24
2,1
1500
3000
1,40
3,7
1x0,34
22
3.1
450
1500
1,30
4,2
1x0,34
22
3,1
1500
3000
1,60
5,1
1x0,56
20
5,4
450
1500
1,50
6,4
1x0,50
-
4,8
900
2500
1,80
6,9
1x0,56
20
5,4
1500
3000
1,80
7,5
1x0,75
18
7,2
900
2500
2,00
9,6
1x0,75
-
7,2
1500
3000
2,60
12,4
1x0,93
18
8,9
1500
3000
2,10
11,1
n – number of elements d – nominal cross section of the conductor Permissible environment temperature: - LiY; LifY from -20 °C up to +70°C, - LiY-T; LifY-T from -20 °C up to +105°C.
127
Li6Y Flexible FEP insulated conductor Standard: VDE 0881
CONSTRUCTION Conductor: stranded tinned or silver-plated copper wires. Insulation: extruded FEP. Colour: white, brown, green, yellow, grey, pink, blue, red, black, violet
Equipment wires with insulation of FEP mass, Li6Y type, are intended for wiring of all kinds of electronic and medical devices, etc.
APPLICATION
TECHNICAL DATA Construction nxq
128
AWG
Cu number
Nominal voltage
Test voltage
Diameter
Mass
[kg/km]
[V]
[V]
[mm]
[kg/km]
1x0,055
30
0,5
375
1500
0,6
0,9
1x0,055
30
0,5
900
2500
0,8
1,2
1x0,079
28
0,8
375
1500
0,7
1,2
1x0,079
28
0,8
900
2500
0,9
1,5
1x0,12
26
1,2
375
1500
0,8
1,6
1x0,12
26
1,2
900
2500
1,0
2,0
1x0,12
26
1,2
1500
3000
1,3
2,8
1x0,22
24
2,1
375
1500
0,9
2,6
1x0,22
24
2,1
900
2500
1,1
3,1
1x1,22
24
2,1
1500
3000
1,4
4,0
1x0,34
22
3,3
375
1500
1,1
3,9
1x0,34
22
3,3
900
2500
1,3
4,4
1x0,34
22
3,3
1500
3000
1,6
5,4
1x0,56
20
5,4
375
1500
1,3
6,0
1x0,56
20
5,4
900
2500
1,5
6,5
1x0,56
20
5,4
1500
3000
1,8
7,8
1x0,93
18
8,9
900
2500
1,8
10,4
1x0,93
18
8,9
1500
3000
2,1
11,8
1x1,2
16
11,5
900
2500
2,0
13,4
1x1,2
16
11,5
1500
3000
2,3
14,8
n – number of the elements d – nominal cross section of the conductor Permissible environment temperature: from -55 °C up to +200 °C.
Li7Y Flexible ETFE insulated conductor Standard: VDE 0881
CONSTRUCTION Conductor: stranded tin- or silver-plated copper wires. Insulation: extruded ETFE. Colour: white, brown, green, yellow, grey, pink, blue, red, black, violet
Equipment wires with insulation of ETFE mass, Li7Y type, are intended for wiring of all kinds of electronic devices that need high level of mechanical resistance.
APPLICATION
TECHNICAL DATA Cu number
Nominal voltage
Test voltage
Diameter
Mass
[kg/km]
[V]
[V]
[mm]
[kg/km]
2500
0,8
1,1
1500
0,7
1,1
900
2500
0,9
1,4
375
1500
0,8
1,5
1,2
900
2500
1,0
1,9
1,2
1500
3000
1,3
2,5
24
2,1
375
1500
0,9
2,5
1x0,22
24
2,1
900
2500
1,1
2,9
1x1,22
24
2,1
1500
3000
1,4
3,7
1x0,34
22
3,3
375
1500
1,1
3,7
1x0,34
22
3,3
900
2500
1,3
4,2
1x0,34
22
3,3
1500
3000
1,6
5,1
1x0,56
20
5,4
375
1500
1,3
5,7
1x0,56
20
5,4
900
2500
1,5
6,3
1x0,56
20
5,4
1500
3000
1,8
7,3
1x0,93
18
8,9
375
1500
1,55
9,9
1x0,93
18
8,9
900
2500
1,8
1x0,93
18
8,9
1500
3000
2,1
11,6
1x1,2
16
11,5
375
1500
1,8
12,0
1x1,2
16
11,5
900
2500
2,0
12,2
1x1,2
16
11,5
1500
3000
2,3
13,5
Construction nxq
AWG
1x0,055
30
0,5
900
1x0,079
28
0,8
375
1x0,079
28
0,8
1x0,12
26
1,2
1x0,12
26
1x0,12
26
1x0,22
n – number of the elements d – nominal cross section of the conductor Permissible environment temperature:
from -55 °C up to +150°C .
10,5
129
LiYY; So-LiYY Flexible cable for electronic Standard: VDE 0812; PSN 08 C010 Nominal voltage: 250V Test voltage: 1200 V
CONSTRUCTION Conductor: bare or tinned wire strands. Insulation: PVC compound. Sheath: PVC compound. Sheath colour: grey RAL 7032 or grey RAL 7001.
APPLICATION
Flexible equipment and control cables LiYY and So-LiYY type are being used in electronics, especially along with electric current of approximately value of milliampere. They are intended for connection in measuring, control and regulation techniques. Besides that, they are used for wiring of telecommunication equipment and equipment for data processing. So-LiYY mark represents special customer requirement, for instance naked copper string and other
TECHNICAL DATA nxq [mm2]
130
2x0,14 3x0,14 4x0,14 5x0,14 6x0,14 7x0,14 8x0,14 10x0,14 12x0,14 2x0,25 3x0,25 4x0,25 5x0,25 6x0,25 7x0,25 8x0,25 10x0,25 12x0,25 2x0,34 3x0,34 4x0,34 5x0,34
Cu number
Diameter
Mass
[kg/km] 2,7 4,0 5,4 6,7 8,1 9,4 10,8 13,4 16,1 4,8 7,2 9,6 12,0 14,4 16,8 19,2 24,0 28,8 6,5 9,8 13,1 16,3
[mm] 3,2 3,6 3,9 4,8 5,1 5.1 5,5 6,3 6,5 3,6 3,9 4,2 4,8 5,1 5,1 5,8 6,7 6,9 4,4 4,7 5,1 5,6
[kg/km] 13,0 16,0 18,0 21,0 33,0 46,8 63,2 63,8 82,7 18,0 22,4 26,7 27,6 34,8 41,0 48,5 57,9 65,8 26,9 35,4 38,8 47,6
n – number wires q – nominal cross section of the conductor Permissible environment temperature: - for fixed laying cable from -20 °C up to +70 °C - for mobil cable from -5 °C up to +70 °C
nxq [mm2] 7x0,34 8x0,34 10x0,34 12x0,34 2x0,50 3x0,50 4x0,50 5x0,50 6x0,50 7x0,50 8x0,50 10x0,50 12x0,50 2x0,75 3x0,75 4x0,75 5x0,75 6x0,75 7x0,75 8x0,75 10x0,75 12x0,75
Cu number
Diameter
Mass
[mm] 22,8 26,1 32,6 39,2 9,6 14,4 19,2 24,0 28,8 33,6 38,4 48,0 57,6 14,4 21,6 28,8 36,0 43,2 50,4 57,6 72,0 86,4
[kg/km] 6.3 6,9 7,8 8,1 4,9 5,3 5,7 6,4 7,0 7,0 7,7 9,1 9,3 5,6 5,9 6,5 7,0 7,6 7,6 8,4 9,8 10,3
[kg/km] 61,0 65,3 77,2 89,4 35,9 42,3 50,5 63,7 75,8 80,0 88,6 108,0 121,5 46,0 55,0 67,0 81,0 95,0 101,0 129,0 145,5 161,0
LiYCY; So-LiYCY Cables for electronic Standard: VDE 0812; PSN Nominal voltage: 250 V Test voltage: 1200 V
CONSTRUCTION Conductor: bare or tinned wire strands. Insulation: PVC compound. Separator: polyester tape. Screen: tinned copper wires braid. Sheath: PVC compound. Sheath colour: grey RAL 7032 or grey RAL 7001.
APPLICATION
Cables LiYCY and So-LiYCY type are being used as for electric supply and command lines for electroacoustic and tone- frequent systems. Multi- core cables are characterized with small dimensions, so that they are specially suitable for electronic devices application. They are intended for impulse and data transmision in electronics, computer technics, control, measuring and regulation technics. So-LiYCY mark is representing special customer requirement, for example naked copper string and other.
TECHNICAL DATA nxq [mm2] 2x0,14 3x0,14 4x0,14 5x0,14 6x0,14 8x0,14 10x0,14 12x0,14 2x0,25 3x0,25 4x0,25 5x0,25 7x0,25 8x0,25 10x0,25 12x0,25 2x0,34 3x0,34 4x0,34 5x0,34 7x0,34 8x0,34 10x0,34 12x0,34 2x0,50 3x0,50 4x0,50 5x0,50 6x0,50 7x0,50 8x0,50 10x0,50
Cu number
Diameter
Mass
[kg/km] 8,3 10,1 12,4 14,5 17,2 19,0 31,2 32,5 11,5 14,0 16,9 20,4 25,9 35,2 42,4 47,4 14,0 18,0 22,3 32,8 38,2 45,1 53,0 61,9 18,4 24,3 35,5 42,7 49,5 54,0 60,3 73,7
[mm] 3,7 3,9 4,4 5,1 5,7 6.1 7,0 7,2 4,5 4,7 5,1 5,5 5,9 6,5 7,2 7,4 5,0 5,3 5,9 6,5 6,9 7,4 7.5 8,8 5,2 6,0 6,5 7,1 7,8 7,7 8,2 9,9
[kg/km] 18,7 22,0 27,0 36,1 41,9 46,8 63,2 73,8 27,6 32,0 36,4 44,0 53,7 67,3 76,0 86,5 33,9 38,4 48,5 63,5 75,0 83,5 82,0 113,1 43,0 51,3 62,0 82,0 84,8 96,5 106,9 133,0
nxq [mm2] 12x0,50 16x0,50 18x0,50 19x0,50 20x0,50 27x0,50 37x0,50 2x0,75 3x0,75 4x0,75 5x0,75 6x0,75 7x0,75 8x0,75 10x0,75 12x0,75 19x0,75 27x0,75 37x0,75 2x1,0 3x1,0 4x1,0 5x1,0 7x1,0 12x1,0 19x1,0 27x1,0 37x1,0 2x1,5 3x1,5 4x1,5 7x1,5
n – number of the wires, q – nominal cross section of the conductor
Cu number
Diameter
Mass
[mm] 86,4 110,0 120,6 121,5 132,0 170,3 239,0 29,5 36,8 46,0 55,4 64,7 71,2 79,4 99,1 112,5 168,0 248,5 322,8 30,4 44,0 55,8 69,2 87,6 133,7 225,3 309,0 409,0 47,6 64,0 80,9 128,5
[kg/km] 9,9 11,2 11,7 11,7 12,3 13,8 15,9 6,2 6,5 7,2 7,7 8,4 8,4 9,0 10,8 10,8 12,7 16,0 17,3 6,6 7,1 7,6 8,3 9,1 11,8 14,1 17,0 19,1 7,6 8,2 8,8 10,5
[kg/km] 155,0 191,3 215,9 221,5 231,8 302,0 409,0 57,4 65,3 80,7 96,7 106,7 118,0 134,0 170,5 189,0 269 410,0 515,0 55,7 76,0 92,0 114,0 142,3 203,0 346,7 475,0 632,6 89,0 109,2 132,0 204,0
131
LiYCY; So-LiYCY pairs Cables for electronic Standard: VDE 0812; PSN Nominal voltage: 250 V Test voltage: 1200 V
CONSTRUCTION Conductor: bare or tinned wire strands. Insulation: PVC compound. Separator: polyester tape. Screen: tinned copper wires braid. Sheath: PVC compound. Sheath colour: grey RAL 7032 or grey RAL 7001.
APPLICATION
Pair cables LiCY and So-LiYCY type are intended for transmission of impulses and data in electronics, computer technics, control, measuring and regulation technics. Across the cable core there is mutual screen of tinned copper wire. Screen is providing protection from high- frequent signals and guarantees exact data transmission, and simultaneously can be used as grounding. Pair stranding reduce electric coupling between pairs inside the cable, which is contributing to reduction of crosstalk, and also gives a good protection from capacity influence of external electric fields. So-LiYCY mark represents special customer requirement, for instance naked copper string and other.
TECHNICAL DATA nxq [mm2]
132
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
nxq [mm2]
Cu number
Diameter
Mass
[mm]
[kg/km]
[kg/km]
2x2x0,25 3x2x0,25 4x2x0,25 5x2x0,25 8x2x0,25 10x2x0,25 2x2x0,34 3x2x0,34 4x2x0,34 8x2x0,34 12x2x0,34 2x2x0,50 3x2x0,50 4x2x0,50 5x2x0,50
26,9 31,5 36,0 43,4 64,4 76,4 29,9 38,7 47,0 83,0 116,3 38,9 48.9 62,6 76,9
5,9 6,9 7,0 7,4 9,0 10,2 7,0 7,4 8,2 11,0 12,8 7,7 8,9 9,5 10,2
51,0 62,0 70,0 76,0 109,0 143, 61,6 76,0 91,6 160,0 215,5 77,0 97,7 120,6 143,3
12x2x0,50 2x2x0,75 4x2x0,75 5x2x0,75 6x2x0,75 8x2x0,75 10x2x0,75 12x2x0,75 16x2x0,75 20x2x0,75 24x2x0,75 2x2x1,0 3x2x1,0 4x2x1,0 5x2x1,0
160,0 49,7 84,4 100,2 118,0 152,0 190,7 229,0 297,0 395,0 450,0 60,4 80,5 114,3 137,0
14,8 8,5 10,2 11,1 11,9 13,4 15,0 16,4 18,4 20,7 22,5 8,9 9,5 11,7 12,8
292,0 92,0 148,0 174,0 205,0 252,0 324,0 379,0 480,0 640,0 725,0 102,2 123,0 188,3 227,0
6x2x0,50
88,6
11,0
165,0
6x2x1,0
145,5
12,4
226,0
8x2x0,50
113,2
12,3
197,0
8x2x1,0
189,0
13,9
280,0
n – number of wires, q – nominal cross section of the conductor Permissible environment temperature: - for fixed laying cable from -20 °C up to +70 °C, - for mobile cable from -5 °C up to +70 °C.
133
AUDIO CABLES NAUK 001 NAUK 100 NAUK 102
135 136 137
NAUK 200 NAUK 300 NAUK 900, 905 NAUK 901, 904
138 139 140 141
NAUK 001,002,003 Cables for internal wiring Standard: PSN
CONSTRUCTION Conductor: bare copper strand. Insulation: PVC compound or polyethylene. Screen: wrapping of bare copper wires or double wrapping of bare copper wires. Sheath: soft PVC compound. NAUK 001 (VDE: So-LiYDY 1x0,055/0,6mm) NAUK 002 (VDE: So-LiYDY 2x0,055/0,6mm) NAUK 003 (VDE: So-Li2Y2DY 2x0,14/1,0mm)
Cables NAUK 001 and NAUK 002 are sub miniature cables, intended for performing internal connections between some points inside audio devices, where screening of audio signal is needed for protection from the disturbance with maximum space saving for the cable placing. These cables can be finished by soldering or by pressing on connector contact (for instance, miniature connectors for connecting cable's form on boards of printing connections CONNECTAL series 300, nominal value AWG 2230).
APPLICATION
Cable NAUK 003 has excellent frequent characteristic thanks to low length capacity and good protection from disturbance accomplished by application of the ''REUSEN'' screen (2D). This cable is being used for making of cable- forms on merging fields and audio lines concentration, and application of the XLR connectors for connecting devices into appropriate cable gland. This cable represents optimal solution for cabling of lockers and stands.
ELECTRICAL CHARACTERISTICS Characteristic
Unit 0
Value for NAUK 001
NAUK 002
NAUK 003
Conductor resistance at 20 C, max
Ω/km
380
380
134
Capacitance, conductor/conductor, max
nf/km
270
120
70
Working voltage, max
V
50
50
100
Test voltage Amplitude transmission characteristic Rg=50Ω, RL=600Ω, l=10m, f=20Hz20kHz Rg=50Ω, RL=600Ω, l=100m, f=20Hz20kHz Rg=50Ω, RL=600Ω, l=100m, f=10Hz200kHz
V
500
500
500
dB
0 -
0 -
0 +0,2
dB
> 90
> 90
> 100
External disturbance attenuation
CONSTRUCTION DATA Type
Insulation
NAUK 001 NAUK 002
PVC PVC
NAUK 003
PE
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2.3
1,4
3,6
4,2
2,0
6,3
14,1
3,5
19,4
135
NAUK 100 Microphone and modulating one-pair cable Standard: PSN
CONSTRUCTION Conductor: bare copper strand. Insulation: PE. Inner sheath: semi-conductive PE. Screen: double wrapping of bare copper wires. Sheath: soft PVC compound. NAUK 100 (VDE: So-Lif2YS2DY 1x2x0,25/1,5mm)
Cable NAUK 100 presents standard one- pair audio cables, with wide range of application in professional audio systems of all kinds. First of all, this cable is intended for production of connecting cables with XLR connectors. Besides application for transmission of the audio signal line level, these cables can be used for transmission of the microphone signal in areas with normal level of the electrical disturbance.
APPLICATION
Cable is on the 7. International Fair of the Electronics and Informatics in Novi Sad, in 1998 awarded with Gold medal for quality.
ELECTRICAL CHARACTERISTICS Characteristic
136
Unit
NAUK 100
Conductor resistance at 200C, max
Ω/km
83,9
Capacitance, conductor/conductor, max Capacitance, conductor/screen, max
nf/km
70 130
Working voltage, max
V
100
Test voltage
V
500
Amplitude transmission characteristic Rg=50Ω, RL=600Ω, l=10m, f=20Hz-20kHz Rg=50Ω, RL=600Ω, l=100m, f=10Hz-200kHz
dB
0 +0,2
External disturbance attenuation
dB
> 100
CONSTRUCTION DATA Type NAUK 100
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
25,5
6,5
64
NAUK 102 Flexible microphone star quads cable Standard: PSN
CONSTRUCTION Conductor: bare copper strand. Insulation: PE. Inner sheath: PVC compound. Screen: double wrapping of bare copper wires. Sheath: soft PVC compound. NAUK 102 (VDE: So-Lif2YY2DY 2x2x0,25/1,2mm)
Cable NAUK 102 is being used for production of the flexible microphone connecting cables and microphone installation line in areas with high level of the electrical disturbance for the XLR connectors. In regard to classic cables it is being characterized with considerably higher degree of repression of the electromagnetic induced disturbance.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristic
Unit
NAUK 102
0
Conductor resistance at 20 C, max
Ω/km
83,9
Capacitance, conductor/conductor, max Capacitance, conductor/screen, max
nf/km
70 105
Working voltage, max
V
100
Test voltage
V
500
Amplitude transmission characteristic Rg=50Ω, RL=600Ω, l=10m, f=20Hz-20kHz Rg=50Ω, RL=600Ω, l=100m, f=10Hz-200kHz
dB
0 +0,2
External disturbance attenuation
dB
> 120
CONSTRUCTION DATA Type NAUK 102
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
29,2
7,0
64
137
NAUK 201,202,205 Multi pair audio cables Standard: PSN
CONSTRUCTION Conductor: flexible copper conductor. Insulation: PE. Screen over pair: double wrapping of bare copper wires. Separation sheath: PVC compound. Screen over core: Bare copper wire braid Sheath: soft PVC. NAUK 201 (VDE: So-Li2Y(2DY)CY 8x2x0,14/1,0mm) NAUK 202 (VDE: So-Li2Y(2DY)CY 10x2x0,14/1,0mm) NAUK 205 (VDE: So-Li2Y(2DY)CY 4x2x0,14/1,0mm)
Multi pair audio cables are being used everywhere where is grouping of the related lines needed for transmission of the signals with optimal usage of the available space. They can be used in fixed installations- cable channels, pipes or shelves, and for production of the movable connecting cables-cable sheaves.
APPLICATION
They are distinguished with great characteristics of transmission of the audio signals, involving high level of the weakening of the cross-talking between pairs (separation of the channel). These cables are electro-mechanically compatible with large number of the popular connectors for the professional audio devices and systems.
ELECTRICAL CHARACTERISTICS Unit
NAUK 201,202,205
Conductor resistance at 200C, max
Ω/km
134
Capacitance, conductor/conductor, max
Characteristic
138
nf/km
70
Working voltage, max
V
100
Test voltage
V
500
Amplitude transmission characteristic Rg=50Ω, RL=600Ω, l=10m, f=20Hz-20kHz Rg=50Ω, RL=600Ω, l=100m, f=10Hz-200kHz
dB
0 +0,05
Cross-talk attenuation between pairs Rg=50Ω, RL=600Ω, l=10m, f=20Hz-20kHz Rg=50Ω, RL=600Ω, l=100m, f=10Hz-200kHz
dB
> 100 > 80
External disturbance attenuation
dB
> 120
CONSTRUCTION DATA Type
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
NAUK 201
127
13,6
250
NAUK 202
186
15,8
295
NAUK 205
84
10,6
145
NAUK 300 Cables for speaker-phones Standard: PSN
CONSTRUCTION Conductor: flexible copper conductor. Insulation: PE. Screen over wire: wrapping of bare copper wires. Sheath: soft PVC compound. NAUK 300 (VDE: So-Lif2Y(D)Y 4x0,5/1,8m)
Cable NAUK 300 is intended for connection of the technical speaker-phones three- wire asymmetric connection configuration (Lola series 41 000, clear- com. telex and others), with movable connecting cables with XLR connectors.
APPLICATION
ELECTRICAL CHARACTERISTICS Characteristics
Unit
NAUK 300
Ω/km
40,1
Working voltage, max
V
100
Test voltage
V
500
Amplitude transmission characteristic Rg=50Ω, RL=600Ω, l=10m, f=20Hz-20kHz
dB
0
External disturbance attenuation
dB
> 90
0
Conductor resistance at 20 C, max
CONSTRUCTION DATA Type NAUK 300
139
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
23,8
7,0
55,0
NAUK 900, 905 Cables for loudspeakers Standard: PSN
CONSTRUCTION Conductor: very flexible copper conductor. Insulation: PVC compound. Sheath: crystal PVC. NAUK 900 (VDE: So-LiYY-H2 2x6/5,0mm) NAUK 905 (VDE: So-LiYY-H2 2x2,5/3,3mm)
APPLICATION
Cable NAUK 900 and NAUK 905 are being used for production of flexible connections between power amplifier and loudspeakers in studio monitor systems and professional sound systems, with fixed connections with help of pressed cable contacts-pedal DIN 46231, DIN 46234, DIN 46245 and others. Bigger conductor diameterlower length cable resistance provides minimum aggravation of the factors that mute loudspeakers, which is the optimal quality of the signal transmission from the power amplifier in sound system.
ELECTRICAL CHARACTERITICS Characteristic
Unit
NAUK 900
Ω/km
3,37
Working voltage, max
V
250
100
Test voltage
V
1000
500
Amplitude transmission characteristic Rg=0Ω, RL=8Ω, l=50m, f=20Hz-20kHz
dB
0
0
Cable attenuation Rl=8Ω, l=50mm
dB
< 0,2
-
Conductor resistance at 200C, max
140
NAUK 905 7,67
CONSTRUCTION DATA Cu number
Height x width
Mass
[kg/km]
[mm]
[kg/km]
NAUK 900
119,0
7x12
190,0
NAUK 905
49,0
5x8,3
90,0
Type
NAUK 901, 904 Cables for loudspeakers Standard: PSN
CONSTRUCTION Conductor: very flexible copper conductor. Insulation: PVC compound. Outer conductor: copper wires wrapping. Sheath: soft PVC compound. NAUK 901 (VDE: So-LiYDY 1x2,5/2,5mm2) NAUK 904 (VDE: So-LiYDY 1x6,0/6,0mm2)
APPLICATION
Cables NAUK 901 and NAUK 904 are used for production of movable flexible connecting cables for connecting sound system with power amplifiers and installation connection of the sound lines in the professional sound system, with the help of the connectors. For production of connecting cables (NAUK 904) appropriate are special sound connectors NEUTRIK "SPEAKON" (series NL4FC), which are accepted in the hole world as a standard for sound connectors. Conventional XLR connectors can be used with cable NAUK 901.
ELECTRICAL CHARACTERITICS Characteristic
Unit
NAUK 901
Conductor resistance at 200C, max
Ω/km
7,98
Capacitance, conductor/conductor, max
pF/m
700
NAUK 904 3,10 800
Working voltage, max
V
100
100
Test voltage
V
500
500
Amplitude transmission characteristic Rg=0Ω, RL=8Ω, l=50m, f=20Hz-20kHz
dB
0
0
Cable attenuation Rl=8Ω, l=50mm
dB
-
< 0,2
CONSTRUCTION DATA Type
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
NAUK 901
48,0
6,8
83,0
NAUK 904
118,0
9,6
182,0
141
HALOGEN FREE CABLES LiHH LiHCH H05Z H07Z H07ZZ-F NHXMH N2XH N2XH FE 180 N2XSH N2XS(E)H
143 144 145 146 147 148 149 150 151 152
NHXHX NHXHX FE 180 NHXCHX NHXCHX FE 180 LiHXHX LiHXHX FE 180 LiHXCHX LiHXCHX FE 180 ILAN 120 (ohm) H J-02Y(St)H
153 154 155 156 157 158 159 160 161 162
J-2Y(St)H TC 88 K (EK) TZ 88 E (GE) THI THM J-HH J-H(St)H JE-H(St)H FE 20 JE-H(St)H FE 180 MGH, MGCH, FMGCH NFK MGH, NFK MGCH, NFK FMGCH
163 164 166 167 168 169 170 171 172 173 174
LiHH Halogen free cable for electronic Standard: PSN Nominal voltage: 250 V Test voltage: 1500 V
CONSTRUCTION Conductor: fine stranded copper conductor, class 5. Insulation: fire retardant – base on polyolefine or similar polymer. Sheath: slow-burning material - based on the polyolefin or the suitable synthetic polymer.
APPLICATION
Flexible equipment and control cables LiHH type are being used in electronics, specially along with electric current of approximately value of mill ampere. They are intended for connection in measuring, control and regulation techniques. Besides that, they are used for wiring of telecommunication equipment and equipment for data processing. Cable LiHH has the same application as the cable LiYY, but without halogen.
CONSTRUCTION DATA nxq
Cu number
Diameter
Mass
nxq
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
6,24 12,5 15,3 20,5 33,09 24,56 32,5 43,13 66,84 3,75 3,95 4,85 5,25 5,65 7,16 7,60 8,80 9,65 10,10 10,30 10,90 10,90 2,40 3,95 4,85 5,25 5,65 5,65
6,3 12,5 15,3 20,5 33,1 24, 6 32,5 43,2 66,9 16,8 21,3 25,3 33,3 36,3 66,7 75,4 97,2 116,3 129,8 140,0 151,8 151,8 12,6 30,7 36,7 45,3 50,7 60,1
1x0,14 2x0,14 3x0,14 5x0,14 6x0,14 7x0,14 8x0,14 10x0,14 14x0,14 2x0,25 3x0,25 4x0,25 5x0,25 6x0,25 12x0,25 14x0,25 20x0,25 22x0,25 24x0,25 27x0,25 32x0,25 33x0,25 1x0,34 3x0,34 4x0,34 5x0,34 6x0,34 7x0,34
1,4 2,7 4,1 6,8 8,2 9,5 10,8 13,5 19,0 4,8 7,2 9,6 12,0 14,4 29,0 34,0 48,0 53,0 58,0 65,0 77,0 80,0 3,3 9,9 13,2 16,5 20,0 23,0
8x0,34 10x0,34 16x0,34 19x0,34 21x0,34 30x0,34 33x0,34 36x0,34 2x0,50 3x0,50 5x0,50 6x0,50 7x0,50 8x0,50 12x0,50 16x0,50 20x0,50 24x0,50 36x0,50 1x0,75 2x0,75 3x0,75 4x0,75 7x0,75 8x0,75 10x0,75 30x0,75 5x1,0
n – number of the conductors, q – nominal cross section of the conductor Permissible envirement temperature: -30 to +80°C. Smallest bending radius: 4D (D – cable diameter).
27,0 33,0 54,0 63,0 70,0 99,0 110,0 120,0 9,6 14,4 24,0 30,0 34,0 39,0 58,0 78,0 96,0 116,0 173,0 7,2 14,4 21,6 29,0 51,0 58,0 72,0 216 48,0
6,05 6,95 7,95 8,35 8,80 10,60 10,90 11,40 5,25 5,55 6,50 7,05 7,05 7,60 9,10 10,60 11,70 12,90 15,70 3,10 5,70 6,00 6,55 7,70 8,35 10,10 16,10 7,55
61,4 73,4 94,3 109,0 120,2 173,3 220,0 236,1 32,5 38,9 60,4 73,4 74,3 89,5 122,4 159,2 195,4 226,1 330,5 20,1 36,3 48,2 59,3 96,6 121,0 127,2 407,0 92,4
143
LiHCH Halogen free cable for electronic Standard: PSN Nominal voltage: 250 V Test voltage: 1500 V
CONSTRUCTION К ОN NS ST TR UK CIIJJA A КО RU KC Conductor: fine stranded copper conductor, class 5. Insulation: slow-burning material - based on the polyolefin or the suitable synthetic polymer. Separator: polyester foil. Screen: tinned copper wire braid. Sheath: slow-burning material - based on the polyolefin or the suitable synthetic polymer.
APPLICATION
Flexible cables are used as power and control cables for electroacoustic and tone-frequency systems. They are intended for the transfer of momentum and the data in electronics, computer technology, control, and measurement and regulation techniques. Cable LiHCH has the same application as the cable LiYCY, but without halogen.
CONSTRUCTION DATA
144
nxq
Cu number
Diameter
Mass
nxq
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
5,4 5,8 6,4 6,9 7,8 11,2 11,6 12,7 5,8 6,5 7,8 9,5 9,8 12,2 13,2 15,7 16,5 17,0 6,6 7,5 11,5 12,5 13,6 15,1 16,2 17,7 18,2
43,4 52,0 58,0 78,1 96,2 194,0 238,0 301,0 57,6 67,6 108,8 143,7 175,5 296,1 367,7 459,7 527,8 584,8 78,8 125,4 298,8 347,0 417,4 495,5 554,4 738,5 768,5
62 69 92 109 139 185 269 354 443 515 646 687 95 144 167 194 227 420 526 169 219 322 347 236 297 437 496
7,1 7,5 8,2 8,8 10,5 12,2 13,7 16,5 18,0 19,3 21,7 22,5 8,8 9,5 9,9 11,5 13,2 16,5 18,1 11,3 12,6 14,2 15,9 12,8 13,6 15,8 18,2
87,4 99,4 118,6 155,6 201,8 309,3 383,3 541,4 683,8 800,4 884,3 938,7 126,7 164,0 187,8 225,5 337,3 559,2 660,4 239,8 307,7 378,4 447,9 325,4 408,3 510,9 666,2
2x0,5 3x0,5 4x0,5 5x0,5 7x0,5 16x0,5 20x0,5 25x0,5 2x0,75 3x0,75 6x0,75 8x0,75 10x0,75 18x0,75 21x0,75 32x0,75 36x0,75 37x0,75 3x1 5x1 14x1 16x1 19x1 24x1 27x1 34x1 37x1
32 38 45 52 64 120 169 235 38 47 68 82 135 204 226 298 355 379 52 83 183 199 247 298 349 419 462
2x1,5 3x1,5 4x1,5 5x1,5 7x1,5 10x1,5 14x1,5 20x1,5 24x1,5 28x1,5 35x1,5 37x1,5 2x2,5 3x2,5 4x2,5 5x2,5 7x2,5 12x2,5 18x2,5 3x4 4x4 5x4 7x4 3x6 4x6 5x6 7x6
n – number of the conductors, q – nominal cross section of the conductor Permissible envirement temperature: -20 to +80°C Smallest bending radius: 4D (D – cable diameter)
H05Z Halogen free cables Standard: DIN VDE 0282-9; HD 22.9 Nominal voltage U0/U: 300/500 V Test voltage: 2000 V
CONSTRUCTION H05Z-U
Conductor: in accordance with DIN VDE 0295 for type: H05Z-U copper conductor, class 1 H05Z-K copper conductor, class 5 Insulation: slow-burning material - based on the polyolefin or the suitable synthetic polymer (EI5, DIN VDE 0282-1)
H05Z-K
Insulated conductor can be used for installation, in the dry room, lighting equipment and control instruments. Cable H05Z has the same application as H05V cable, but it is halogen free.
APPLICATION
CONSTRUCTION DATA q 2
[mm ]
Cu Number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
0,5
4,9
2,3
9,6
0,75
7,4
2,5
12,4
1
9,8
2,7
15,0
q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +90°C - in short circuit (max 5 s), max +250°C Permissible envirement temperature: - at laying and handling, min +5°C - at storage, max +40°C Smallest bending radius: 4D (D – cable diameter)
145
H07Z Halogen free cables Standard: DIN VDE 0282-9; HD 22.9 Nominal voltage U0/U: 450/750 V Test voltage: 2500 V
CONSTRUCTION Conductor: according to DINVDE 0295 for type H07Z-U copper conductor, class 1 H07Z-R copper conductor, class 2 H07Z-K copper conductor, class 5 Insulation: slow-burning material - based on the polyolefin or the suitable synthetic polymer, (EI5, DIN VDE 0282-1)
Insulated halogen free conductor with improved characteristics is supstitute for H07V cable in case of fire and it is used for installations in the dry room, lighting equipment and control instruments.
APPLICATION
CONSTRUCTION DATA q 2
[mm ]
146
1,5 2,5 4 6 10 16 25 35 50 70 95 120 150 185 240
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
15 24 39 58 96 154 240 336 480 672 912 1152 1440 1776 2304
3,1 3,8 4,3 4,8 6,4 7,7 9,1 10,8 13,0 14,8 16,9 19,2 21,1 22,7 27,1
20,7 32,7 48,2 67,0 121,0 188,5 274,0 377,0 532,0 749,0 995,0 1233,0 1541,0 1931,0 2496,0
q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +90°C - in short circuit (max 5 s), max +250°C Permissible envirement temperature: - at laying and handling, min +5°C - at storage, max +40°C Smallest bending radius: 4D (D – cable diameter)
H07ZZ-F Halogen free flame retardant cables Standard: VDE 0282-13; HD 22.13 S1 Nominal voltage U0/U: 450/750 V (for fix laying cable 0,6/1 kV) Test voltage: 2500 V
CONSTRUCTION Conductor: copper conductor (DIN VDE 0295, class 5). Insulation: halogen free cross-linked compound based on polyolefin or synthetic polymer (EI8, DIN VDE 0282-1). Sheath: halogen free cross-linked compound based on polyolefin (EM8, DINVDE 0282-1).
Sheath colour black.
APPLICATION
Halogen free cables with improved characteristics in the case of fire are intended as substitute for H07RN-F cable in installation in the object where there are rather large requirements for safety of people and property - not spreading the fire, not producing dangerous smoke - it is built in buildings where making evacuation is difficult and where is very important to prevent fast spreading of a fire. These cables are used for connecting electrical appliances and tools, and installations with medium mechanical stresses. Cables can used as power, signal and control cable. Cables are not suitable to be put in the open air permanently.
CONSTRUCTION DATA nxq [mm2] 1x1,5 1x2,5 1x4 1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 1x120 1x150 1x185 1x240 2x1 2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 3G1 3G1,5
Cu number Diameter [kg/km] [mm] 15 6,5 24 7,0 39 8,0 58 9,0 96 10,5 154 12,0 240 14,0 336 16,0 480 18,5 672 21,0 912 24,0 1152 26,0 1440 28,0 1776 31,0 2304 35,0 19 9,0 29 10,0 48 11,5 77 13,5 116 14,5 192 20,0 308 23,0 480 27,5 29 9,5 44 10,5
Mass [kg/km] 54 71 97 124 208 285 398 525 720 969 1276 1580 1941 2390 3024 104 130 186 247 333 637 842 1197 125 157
nxq [mm2] 3G2,5 3G4 3G6 3G10 3G16 4G1 4G1,5 4G2,5 4G4 4G6 4G10 4G16 5G1 5G1,5 5G2,5 5G4 5G6 5G10 7G1,5 7G2,5 12G1,5 12G2,5 19G1,5 19G2,5 24G1,5
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible envirement temperature: - at laying and handling, min +5°C, - at storage, max +40°C. Smallest bending radius: 4D (D – cable diameter).
Cu number Diameter [kg/km] [mm] 72 12,5 116 15,0 173 16,0 288 21,5 461 25,0 39 10,5 58 11,5 96 13,5 154 16,0 231 18,0 384 24,0 615 27,0 48 11,5 72 12,5 120 15,0 192 18,0 288 20,0 480 26,0 101 17,0 168 19,0 173 20,0 288 23,0 274 24,0 456 28,0 346 28,0
Mass [kg/km] 226 313 409 789 1049 152 191 275 388 516 970 1325 189 233 336 479 635 1181 370 518 528 754 801 1163 989
147
NHXMH Halogen free installation cable Standard: DIN VDE 0250 part 214 Nominal voltage: 300/500 V Test voltage: 2000 V
CONSTRUCTION Conductor: wire or rope with soft heated copper class 1 or 2 in accordance with DIN VDE 0295. Insulation: halogen free cross-linked compound. Core: two or more cores are stranded together. Filler: extruded halogen free layer over stranded wires. Sheath: thermoplastic halogen free layer. Sheath colour light gray, RAL 7035.
APPLICATION
For installation for permanent laying in dry and wet spaces over, on, in and under plaster. The direct laying into vibrant and over stressed plaster is not permissible. It can be placed in free space, if protected from direct solar radiation. It cannot be placed to the land and water. Characteristics of the cable in case of fire: - do not spread flame, - combustion elements do not contain halogen elements, - has a low density of smoke in the process of fire.
CONSTRUCTION DATA nxq 2
148
[mm ] 1x1,5 1 x2,5 1 x4 1 x6 1 x10 1 x16 2 x1,5 2 x2,5 2 x4 2 x6 2 x10 3 x1,5 3 x2,5 3 x4 3 x6 3 x10 3 x16
Cu number Diameter [kg/km] 15 24 38 58 96 154 29 48 77 115 192 43 72 115 173 288 460
[mm] 5,5 5,9 6,7 7,2 8,4 10,0 9,0 9,9 11,4 12,5 15,7 9,4 10,4 12,0 13,7 16,1 19,6
Mass [kg/km] 40 53 73 96 144 214 105 138 193 252 406 123 166 235 325 507 761
nxq 2
[mm ] 4 x1,5 4 x2,5 4 x4 4 x6 4 x10 4 x16 4 x25 4 x35 5 x1,5 5 x2,5 5 x4 5 x6 5 x10 5 x16 5 x25 7 x1,5 7 x2,5
n – number of the elemetns, q – nominal cross section of the conductor Permissible conductor temperature: - operating temperature, max +90°C, - in short circuit (max 5 s), max +250°C. Permissible envirement temperature: - for fix laying cables, –30°C to +70°C, - for movable cables, –5°C to +60°C. Smallest bending radius: 12D (D – cable diameter).
Cu number Diameter [kg/km] 58 96 154 230 384 614 960 1344 72 120 192 288 480 768 1200 100 168
[mm] 10,1 11,2 13,4 15,3 17,7 21,6 27,0 30,3 10,9 12,1 15,0 16,5 19,0 24,3 29,7 11,7 13,5
Mass [kg/km] 145 199 299 415 636 957 1488 1975 169 234 369 493 749 1185 1805 206 303
N2XH Halogen free cables with improved characteristics in case of fire Standard: DIN VDE 0276 Nominal voltage U0/U: 0,6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper conductor class 1 or class 2 according to DIN VDE 0295 Insulation: cross-linked polyethylene (XLPE) Core: for multi-core cable cores are stranded together. Filler: halogen free material, fire retardant Sheath: thermoplastic halogen free layer. Sheath colour black For permanent laying in dry and wet areas over, on, in and under plaster. They are laid in pipes in land or in free air. They are intended for buildings where large numbers of people residing and / or are value equipment, such as industrial plants, hotels, airports, department stores, hospitals, cinemas, ...
APPLICATION
CONSTRUCTION DATA nxq [mm2] 1x4
Cu Diamet. Mass [kg/km] [mm] [kg/km] 39
6,5
71
nxq [mm2] 3x4
Cu Diamet. Mass [kg/km] [mm] [kg/km] 116
13,5
287
nxq [mm2] 4x150
Cu Diamet. Mass [kg/km] [mm] [kg/km] 5760
46,0
6527
1x6
58
7,0
91
3x6
173
16,0
420
4x185
7104
50,5
7949
1x10
96
8,0
151
3x10
288
18,0
600
4x240
9216
53,5
9894
1x16
154
9,0
205
3x16
461
18,5
765
5x1,5
72
12,0
206
1x25
240
10,5
302
3x25
720
24,5
1300
5x2,5
120
13,0
268
1x35
336
12,0
404
3x35
1008
24,5
1366
5x4
192
14,0
364
1x50
480
13,5
556
3x50
1440
27,0
1800
5x6
288
15,5
486
1x70
672
16,0
765
3x70/35
2352
33,0
3000
5x10
480
18,0
723
1x95
912
17,0
1006
3x95/50
3216
37,5
4000
5x16
768
22,0
1129
1x120
1152
18,5
1254 3x120/70
4128
41,0
5100
5x25
1200
26,5
1727
1x150
1440
21,0
1578 3x150/70
4992
46,5
6100
7x1,5
101
12,5
245
1x185
1776
23,0
1925
4x1,5
58
11,0
174
7x2,5
168
14,0
333
1x240
2304
26,0
2466
4x2,5
96
11,5
208
12x1,5
173
16,5
386
1x300
2880
33,0
3500
4x4
154
14,0
302
12x2,5
288
21,0
563
2x1,5
29
9,5
132
4x6
231
14,5
365
14x1,5
202
17,5
456
2x2,5
48
10,5
161
4x10
384
16,5
628
14x2,5
336
22,0
640
2x4
77
14,5
280
4x16
615
21,0
972
19x1,5
274
18,5
530
2x6
116
15,5
350
4x25
960
24,0
1309
19x2,5
456
24,0
807
2x10
192
17,0
480
4x35
1344
26,5
1802
24x1,5
346
21,5
698
2x16
307
19,5
650
4x50
1920
27,5
2213
24x2,5
576
27,0
995
2x25
480
23,5
1000
4x70
2688
32,5
3096
30x1,5
432
23,5
804
3x1,5
44
10,0
149
4x95
3648
35,5
4037
30x2,5
720
28,5
1190
3x2,5
72
11,0
196
4x120
4608
40,0
5115
40x2,5
576
25,5
1017
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min -5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
149
N2XH FE 180 Halogen free cable with improved characteristics and insulation function in case of fire Standard: DIN VDE0276 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper class 1 or class 2 (DIN VDE 0295). Separator: mica tape. Insulation: cross-linked polytehylene (XLPE). Ispuna: halogen free, flame retardant material. Plašt: thermoplastic halogen free flame retardant material. Sheath colour orange.
APPLICATION
Halogen free cables with improved characteristics and isolation functionality in case of fire: - do not spread fire and flame, - products of the combustion are not corrosive, - low smoke density during combustion. - they can supply power in the fire, minimum 180 minute - FE 180. This type is suitable for high housing and office buildings, department stores, theaters, cinemas, etc. where are a lot of people or value equipment. These cables are intended for installation in the object where there are rather large requirements for safety and where making evacuation is difficult and where is very important to prevent fast spreading of a fire. These cables are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc). It can be put in the air on the shelf or in the cement in cable canal. It is allowed to be put in the open air. It is not allowed to be put in the earth or in the water.
150
CONSTRUCTION DATA nxq 2
[mm ] 1x25 1x35 1x50 1x70 2x1,5 3x1,5 3x2,5 3x4 3x6 4x1,5 4x2,5
Cu number Diameter [kg/km] 240 336 480 672 29 44 72 116 173 58 96
[mm] 13 14 16 17 14 15 16 17 18 16 17
Mass [kg/km] 345 445 635 848 255 286 338 404 489 332 394
nxq 2
[mm ] 4x4 4x6 4x50 4x70 4x95 5x1,5 5x2,5 5x4 5x6 5x10 5x16
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min -5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
Cu number Diameter [kg/km] 154 231 1920 2688 3648 72 120 192 288 480 768
[mm] 18 19 36 40 45 17 18 19 21 23 27
Mass [kg/km] 480 604 2866 3899 5174 396 465 581 722 980 1337
N2XSH Medium voltage halogen free cable Standard: DIN VDE 0276 part 622 Nominal voltage U0/U: 6/10 kV 12/20 kV Test voltage: 15 kV 30 kV
20/35 kV 50 kV
CONSTRUCTION Conductor: multi-wires copact copper or aluminium (A) conductor class 2 in accordance with DIN VDE 0295. Semi-conductive layer: extruded layer. Insulation: cross-linked polyethylene (XLPE). Semi-conductive layer: extruded layer, semi-conductive tape. Protective conductor: copper wires with tape as counter spiral or copper tapes. Separator: polyester tape. Sheath: thermoplstic halogen free flame retardant material. Sheath colour black.
APPLICATION
For permanent laying in dry and wet spaces over, on, in and under plaster. They are laid in pipes in land or in free air. They are intended for buildings where large numbers of people residing and / or are value equipment, such as industrial plants, hotels, airports, department stores, hospitals, cinemas, etc.
CONSTRUCTION DATA Cu conductor nxq/q1 [mm2]
Cu number
Diameter
[kg/km]
[mm]
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
26,0 28,0 29,5 31,0 32,5 34,0 35,5 39,0
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
30,5 32,5 33,0 35,0 37,0 39,0 41,5 43,0
1x50/16 1x70/16 1x95/16 1x120/16 1x150/25 1x185/25 1x240/25 1x300/25
622 854 1094 1334 1723 2059 2587 3163
37,5 39,0 40,0 42,0 43,0 44,5 48,0 50,5
Al conductor Mass
Al number
[kg/km] [kg/km] 6/10 kV 1010 145 1266 203 1535 276 1792 348 2210 435 2534 537 3136 696 3851 870 12/20 kV 1238 145 1458 203 1731 276 1984 348 2414 435 2854 537 3478 696 4028 870 20/35 kV 1598 145 1877 203 2175 276 2453 348 2879 435 3240 537 3993 696 4602 870
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
182 182 182 182 283 283 283 283
26,0 28,0 29,5 31,0 32,5 34,0 35,5 39,0
695 821 931 1030 1239 1412 1611 1894
182 182 182 182 283 283 283 283
30,5 32,5 33,0 35,0 37,0 39,0 41,5 43,0
913 994 1148 1222 1467 1665 1917 2055
182 182 182 182 283 283 283 283
37,5 39,0 40,0 42,0 43,0 44,5 48,0 50,5
1298 1443 1580 1706 1932 2104 2469 2675
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
151
N2XS(E)H Medium voltage halogen free cable Standard: DIN VDE 0276 part 622 Nominal voltage U0/U: 6/10 kV 12/20 kV 20/35 kV Test voltage: 15 kV 30 kV 50 kV
CONSTRUCTION Conductor: multi-wires copact copper or aluminium (A) conductor class 2 in accordance with DIN VDE 0295. Conducter screen: extruded Insulation: cross-linked polyethylene (XLPE). Semi-conductive layer: extruded layer, semi-conductive tape. Protective conductor: copper wires with tape as counter spiral or copper tapes. Filler: halogen free material. Sheath: thermoplstic halogen free flame retardant material. Sheath colour black.
For permanent laying in dry and wet spaces over, on, in and under plaster. They are laid in pipes in land or in free air. They are intended for buildings where large numbers of people residing and / or are value equipment, such as industrial plants, hotels, airports, department stores, hospitals, cinemas, etc.
APPLICATION
CONSTRUCTION DATA
152
nxq/q1 [mm2]
Cu conductor
Al conductor
Cu number
Diameter
Mass
Al number Cu number Diameter
[kg/km]
[mm]
[kg/km]
[kg/km]
[kg/km]
[mm]
Mass [kg/km]
3x50/16
1671
51,5
3714
435
231
51,5
2751
3x70/16
2247
55,5
4583
609
231
55,5
3236
3x95/16
2994
60,0
5703
827
258
60,0
3873
3x120/16
3714
62,5
6617
1044
258
62,5
4306
3x150/25
4603
68,0
7989
1305
315
68,0
5039
3x185/25
5611
69,5
9051
1610
315
69,5
5489
3x240/25
7272
76,5
11318
2088
362
76,5
6696
3x300/25
9160
80,0
13632
2610
520
80,0
7793
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: - operating temperature, max +90°C; - in short circuit (max 5 s), max +250°C. Permissible envirement temperature: - at laying and handling, min +5°C. Smallest bending radius: 15D (D – cable diameter).
NHXHX Halogen free cable with improved characteristics in case of fire Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper conductor (DIN VDE 0295 class 1 or class 2). Insulation: halogen free corsslinked compound base on polyolefin (HXI1 DIN VDE 0266). Filler: halogen free compound. Sheath: halogen free corsslinked compound base on polyolefin (HXM1, prema DIN VDE 0266). Sheath colour: black for power cables; blue: for cable that is used for self-safety circuits
APPLICATION
Cables are intended for installation in buildings with increased requirements for safety of people and property, in buildings where the rescue of people and animals is difficult (high buildings all types in which resides a number of people and animals), public, business and other objects for which if very important not to spread fire fast and endangering people with smoke. It can be put in the air on the shelf or in the cement in the cable canal. It is allowed to be put in the open air. It is not allowed to be put in the earth or in the water.
CONSTRUCTION DATA nxq
Cu number
Diameter
Mass
nxq
Cu number
Diameter
Mass
2
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
1x6 1x10 1x16 1x25 1x35 1x50 1x70 1x95 2x1,5 2x2,5 3x1,5 3x2,5 3x4 3x6 4x1,5 4x2,5 4x4 4x6
58 96 154 240 336 480 672 912 29 48 44 72 116 173 58 96 154 231
8 9 10 11 12 15 16 18 12 13 13 14 15 16 14 15 16 17
117 165 240 349 455 622 832 1116 198 235 224 272 339 425 260 319 408 516
4x10 4x25 4x35 4x50 4x70 4x95 4x120 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25 7x1,5 10x1,5 21x1,5 40x1,5
384 960 1344 1920 2688 3648 4608 72 120 192 288 480 768 100 101 144 303 576
19 26 28 33 38 43 46 15 16 17 18 20 24 28 16 19 24 32
[mm ]
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
727 566 036 851 846 136 268 306 373 482 614 877 1 296 1 906 364 517 859 1 517 1 2 2 3 5 6
153
NHXHX FE 180 Halogen free cable with insulation funcionality in case of fire Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper conductor (DIN VDE 0295 class 1 or class 2) Separator: glass-liscun tape (hardly flammable material) Insulation: halogen free cross-linked compound based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Sheath: halogen free cross-linked compound based on polyolefin, heavy inflammable slow-burning material which release a little smoke (HXM1, DIN VDE 0266). Colour orange.
APPLICATION
These cables are intended for installation in the object where there are rather large requirements for safety of people and property - not spreading the fire, not producing dangerous smoke - it is built in buildings where making evacuation is difficult and where is very important to prevent fast spreading of a fire. These cables are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc). It can be put in the air on the shelf or in the cement in cable canal. It is allowed to be put in the open air. It is not allowed to be put in the earth or in the water.
CONSTRUCTION DATA
154
nxq 2
[mm ] 1x25 1x35 1x50 1x70 2x1,5 3x1,5 3x2,5 3x4 3x6 4x1,5 4x2,5
Cu number
Diameter
Mass
nxq
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
240,0 336,0 480,0 672,0 28,8 43,2 72,0 115,2 172,8 57,6 96,0
13 14 16 17 14 15 16 17 18 16 17
365 455 641 858 260 296 347 416 509 342 404
4x4 4x6 4x50 4x70 4x95 5x1,5 5x2,5 5x4 5x6 5x10 5x16
153,6 230,6 1920,0 2688,0 3648,0 72,0 120,0 192,0 288,0 480,0 768,0
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
18 19 36 40 45 17 18 19 21 23 27
500 614 2970 4019 5213 406 483 595 735 1010 1457
NHXCHX Halogen free cable with electrical protection Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper conductor (DIN VDE 0295 class 1 or class 2) Insulation: halogen free cross-linked compound based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Concentric conductor: copper wire with counter spiral made from copper tape Sheath: halogen free cross-linked compound, flame retardant, based on polyolefin (HXM1, DIN VDE 0266). Colour: for power cables – black, for cables which are used for self-security current circles - blue.
APPLICATION
This cable is intended for installation in buildings with increased requirements for safety of people and property, in buildings where rescue of people is difficult (high buildings all types in which resides a number of people), public, business and other objects for which it is important not to come to a quick spread of fire and endangering people with smoke. They can be placed in the air on horizontal racks or in concrete in cable channels. It is allowed to lay cables in open space. Laying directly in the ground or water is not allowed.
CONSTRUCTION DATA nxq/q1 2
[mm ] 4x10/10 4x16/16 4x25/16 4x35/16 4x50/25 4x70/35 4x95/50 4x120/70
Cu number [kg/km]
155 Diameter
Mass
nxq/q1 2
[mm]
[kg/km]
[mm ]
24 27 31 34 39 43 47 52
950 1300 1900 2300 3100 4200 5400 6700
7x1,5/2,5 10x1,5/2,5 12x1,5/2,5 24x1,5/6 7x2,5/2,5 10X2,5/4 12x2,5/4 24x2,5/10
504 796 1142 1526 2203 3082 4208 5388
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
20 23 24 31 21 25 26 34
450 650 700 1200 550 800 850 1600
133 176 205 413 200 286 334 696
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
NHXCHX FE 180 Halogen free cabel with protective conductor and inuslation funcionality Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: copper conductor (DIN VDE 0295 class 1 or class 2) Separator: glass-liscun tape (hardly flammable material) Insulation: halogen free cross-linked compound based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Concentric conductor: copper wire with counter spiral made from copper tape Sheath: halogen free cross-linked compound, flame retardant, based on polyolefin (HXM1, DIN VDE 0266). Color: orange.
APPLICATION
This cable is intended for installation in high residential and business buildings, department stores, theaters, cinemas, etc.. when in case of fire such facilities is difficult to leave and where fire cannot be spread for min. 180 minutes of its emergence. These cables are particularly suitable for installation which should be functional in the case of the fire (power supply pumps, equipment to extinguish a fire, ventilators for pulling out of smoke, panic lighting, etc). It can be put in the air on the shelf or in the cement in cable canal that need to preserve the integrity and stability in terms of fire activity in the required time for proper installation.
CONSTRUCTION DATA
156
nxq
Cu number
Diameter
Mass
nxq
Cu number
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
2x1,5/1,5 2x2,5/2,5 2x4/4 2x6/6 2x10/10 3x1,5/1,5 3x2,5/2,5 3x4/4 3x6/6 3x10/10 3x16/16 3x25/25 3x35/35 3x50/50 3x70/70 3x95/95
52 80 123 182 312 66 104 161 240 408 643 1003 1402 2000 2796 3791
16 17 18 19 21 17 18 19 20 22 25 29 32 37 42 47
300 350 420 500 700 320 380 480 600 850 1200 1700 2200 2900 3900 5200
4x1,5/1,5 4x2,5/2,5 4x4/4 4x6/6 4x10/10 4x16/16 4x25/16 4x50/25 4x70/35 4x95/50 7x1,5/2,5 10x1,5/2,5 12x1,5/2,5 7x2,5/2,5 10x2,5/4 12x2,5/4
81 128 200 297 504 796 1142 2203 3082 4208 133 176 205 200 286 334
18 19 20 21 24 27 32 39 44 52 20 24 25 22 26 27
380 450 550 700 1000 1400 1900 3200 4400 6100 500 700 750 650 900 950
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: for one-wire cable 15D; for multi-wires cable 12D (D – cable diameter).
LiHXHX Flexible halogen free cable Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: fine stranded copper (at request) conductor (DIN VDE 0295 class 5) Insulation: halogen free cross-linked compound, based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Sheath: halogen free compound, flame retardant, based on polyolefin (HXM1, DIN VDE 0266). Colour: black
APPLICATION
These flexible cables are used everywhere where there are increased requirements for the safety of people and property, in buildings where rescue of people is difficult (high buildings all types in which resides a number of people), public, business and other objects for which it is important not to rapid spread of fire and endangering people with smoke. They can be placed in the air on racks or in concrete in cable channels. Laying in open space is also allowed. Laying directly in the ground or water is not allowed.
CONSTRUCTION DATA nxq 2
[mm ] 1x6 1x10 1x16 1x25 1x35 2x1,5 2x2,5 3x1,5 3x2,5 3x4 3x6 4x1,5 4x2,5 4x4 4x6
Cu [kg/km]
Diameter [mm]
58 96 154 240 336 29 48 44 72 116 173 58 96 154 231
Mass [kg/km]
8 9 10 11 12 12 13 13 14 15 16 14 15 16 17
117 165 240 349 455 198 235 224 272 339 425 260 319 408 516
nxq 2
[mm ] 4x10 4x25 4x35 4x50 4x70 5x2,5 5x4 5x6 5x10 5x16 5x25 7x1,5 10x1,5 21x1,5 40x1,5
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: 5D (D – cable diameter).
Cu
Diameter
Mass
[kg/km]
[mm]
[kg/km]
384 960 1344 1920 2688 120 192 288 480 768 1200 101 144 303 576
19 26 28 33 38 16 17 18 20 24 28 16 19 24 32
727 1566 2036 2851 3846 373 482 614 877 1296 1906 364 517 859 1517
157
LiHXHX FE 180 Flexible halogen free cable with insulation funcionality Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Ispitni napon: 4 kV
CONSTRUCTION Conductor: fine stranded copper (at request) conductor (DIN VDE 0295, class 5) Separator: glass-liscun tape (hardly flammable material) Insulation: halogen free cross-linked compound, based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Sheath: halogen free cross-linked compound, flame retardant, based on polyolefin, (HXM1, DIN VDE 266). Colour: orange.
Cable is used primarily for installations that need to work in conditions during the fire, such as pumps, electric power devices to increase water pressure in hydrant network and fire extinguishers, for smoke extraction fans and creating an air overpressure, power lights, panic lighting, etc. They can be placed in the air, the concrete cable channels or on racks that need to preserve the integrity and stability in terms of fire activity in the required time for proper installation. Laying in open space is also allowed. Laying directly in the ground or water is not allowed.
APPLICATION
CONSTRUCTION DATA
158
nxq 2
Cu
[mm ]
[kg/km]
1x25 1x35 1x50 2x1,5 3x1,5 3x2,5 3x4 3x6 4x1,5 4x2,5
240,0 336,0 480,0 28,8 43,2 72,0 115,2 172,8 57,6 96,0
Diameter [mm] 13 14 16 14 15 16 17 18 16 17
Mass [kg/km] 365 455 641 260 296 347 416 509 342 404
nxq
Cu
[mm] 4x4 4x6 4x50 4x95 5x1,5 5x2,5 5x4 5x6 5x10 5x16
[kg/km] 153,6 230,4 1 920,0 3 648,0 72,0 120,0 192,0 288,0 480,0 768,0
n – number of the elements, q – nominal cross section of the conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: 5D (D – cable diameter).
Diameter 2
[mm ] 18 19 36 45 17 18 19 21 23 27
Mass [kg/km]
2 5
1 1
500 614 970 213 406 483 595 735 010 457
LiHXCHX Flexible halogen free cable with electrical protection Standard: DIN VDEO266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: fine stranded copper (at request) conductor (DIN VDE 0295, class 5) Insulation: halogen free cross-linked compound, based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Concentric conductor: copper wires with counter helix from copper tape Sheath: halogen free cross-linked compound, flame retardant, based on polyolefin (HXM1, DIN VDE 0266). Colour: black
Flexible cable is used everywhere where there are increased requirements for the safety of people and property, in buildings where rescue of people is difficult (high buildings all types in which resides a number of people), public, business and other objects for which it is important not to rapid spread of fire and endangering people with smoke.
APPLICATION
They can be placed in the air on racks or in concrete in cable channels. Laying in open space is also allowed. Laying directly in the ground or water is not allowed.
CONSTRUCTION DATA nxq/q1 2
[mm ]
Cu [kg/km]
Diameter [mm]
Mass [kg/km]
nxq/q1 2
[mm ]
Cu
Diameter
Mass
[kg/km]
[mm]
[kg/km]
4x10/10
504
24
950
7x1,5/2,5
133
20
450
4x16/16
796
27
1300
10x1,5/2,5
176
23
650
4x25/16
1142
31
1900
12x1,5/2,5
205
24
700
4x35/16
1526
34
2300
24x1,5/6
413
31
1200
4x50/25
2203
39
3100
7x2,5/2,5
200
21
550
4x70/35
3082
43
4200
10X2,5/4
286
25
800
4x95/50
4208
47
5400
12x2,5/4
334
26
850
4x120/70
5388
52
6700
24x2,5/10
696
34
1600
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: 5D (D – cable diameter).
159
LiHXCHX FE 180 Flexible halogen free cable with electrical protection Standard: DIN VDE0266 Nominal voltage U0/U: 0.6/1 kV Test voltage: 4 kV
CONSTRUCTION Conductor: fine stranded copper (at request) conductor (DIN VDE 0295 class 5) Separator: glass-liscun tape (hardly flammable material) Insulation: halogen free cross-linked compound based on polyolefin (HXI1, DIN VDE 0266) Filler: halogen free compound Concentric conductor: copper wires with counter helix from copper tape Sheath: halogen free cross-linked compound, flame retardant, based on polyolefin, (HXM1, DIN VDE 266). Color: orange
APPLICATION
This type of cable is used in high residential and commercial buildings, stores, theaters, cinemas, when in case of fire it is difficult to leave such facilities. It is used primarily for installations that need to work in conditions during the fire, such as pumps, electric power devices to increase water pressure in hydrant network and fire extinguishers, for smoke extraction fans and creating an air overpressure, power lights, panic lighting. They can be placed in the air, the concrete cable channels or on racks that need to preserve the integrity and stability in terms of fire activity in the required time for proper installation. Laying in open space is also allowed. Laying directly in the ground or water is not allowed.
CONSTRUCTION DATA
160
nxq/q1 [mm2] 2x1,5/1,5 2x2,5/2,5 3x1,5/1,5 3x2,5/2,5 3x4/4 3x16/16 3x35/35 3x70/70
Cu [kg/km] 52 80 66 104 161 643 1402 2796
Diameter [mm] 16 17 17 18 19 25 32 42
Mass [kg/km] 300 350 320 380 480 1200 2200 3900
nxq/q1 [mm2] 4x1,5/1,5 4x2,5/2,5 4x10/10 4x25/16 4x50/25 7x1,5/2,5 12x1,5/2,5 12x2,5/4
Cu [kg/km] 81 128 504 1142 2203 133 205 334
Diameter [mm] 18 19 24 32 39 20 25 27
Mass [kg/km] 380 450 1000 1900 3200 500 750 950
n – number of the elements, q – nominal cross section of the conductor, q1 – nominal cross section of the protective conductor Permissible conductor temperature: operating temperature, max +90°C; in short circuit (max 5 s), max +250°C. Permissible envirement temperature: at laying and handling, min +5°C. Smallest bending radius: 5D (D – cable diameter).
ILAN 120 (ohm) H Halogen free installation cable for digital distribution up to 2 Mbps Standard: PSN (in arccodance with CENELEC-EN 50098-1 and CENELEC-EN 50098-2) Nominal voltage: up to 230 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.5 (mm) diameter. Insulation: foam-skin PE. Twisting elements: pairs. Screened pairs: two laminated aluminium foil with a copper drain wire being longitudinally applied under it. Cable core: two or four screened pairs. Sheath: halogen-free, fire retardant polymer with low smoke emission in case of fire.
For interconnection of digital multiplex equipment, digital distribution frames in transmission stations and for ISDN primary multiplex connection ip to 2 Mbps.
APPLICATION
Cable do not spread flame (IEC 60332-3, method C).
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Conductor resistance, max Mutual capacitance, nom Insulation resistance, min Characteristic impedance at 1 MHz Capacitance unbalance, max. pair/screen 1 MHz 4 MHz Attenuation at 10 MHz 16 MHz 20 MHz Crosstalk attenuation at near end 1 MHz, min. far end
ohm/km nF/km G ohm km ohm pF/m dB/km dB/km dB/km dB/km dB/km dB dB
94 45 5 120+12 3.4 25 40 67 81 92 56 61
Value
Dielectric strength wire/wire, 1 minute
Veff
1000
Operating voltage, peak value
V
230
CONSTRUCTION DATA Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x2x0.5
10
5.8
70
4x2x0.5
17
11.5
127
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C.
161
J-02Y(St)H Halogen free installation cable for ISDN Standard: PSN
CONSTRUCTION Conductor: Soft annealed copper wire of 0.6 (mm) diameter. Insulation: halogen free foam-skin PE. Twisting elements: pairs. Cable core: Concentric layer stranded. Core wrapping: Thermoplastic tape . Screen: Laminated aluminium foil Sheath: Halogen-free, fire retardant polymer with low smoke emission in case of fire.
For installation line with no screen pairs in eareas with risk of fire. As ISDN-base connecting cable for indoor installations unshielded for 144 Kbps.
APPLICATION
Cable do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max
130
ohm/km
Insulation rasistance, min Mutual capacitance, max Characteristic impedance at 100 kHz Attenuation at 100 kHz
G ohm km
5
nF/km
40
ohm
150
dB/km
Crosstalk attenuation at 100 kHz Near end
162
Value for 0,6mm
Dielectric strength wire/wire
4.6 55
dB
800
Veff
CONSTRUCTION DATA Construction
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x2x0.6
11
5.5
35
4x2x0.6
25
7.0
55
6x2x0.6
34
8.0
75
8x2x0.6
50
9.0
90
10x2x0.6
57
10.0
110
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C.
J-2Y(St)H Halogen free cable for transfer data Standard: PSN
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 (mm) diameter. Insulation: solid PE. Twisting elements: star quads. Cable core: concentric layer stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire being longitudinally applied under it. Sheath: halogen-free, fire retardant polymer with low smoke emission in case of fire.
For transmission of analogous and digital signals. For installation in areas with risk of fire.
APPLICATION
Cable do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Insulation rasistance, min Mutual capacitance, max k1 Capacitance unbalance, max k9-12 Dielectric wire/wire strength wire/screen
Value ohm/km G ohm km nF/km pF/100 m pF/100 m Veff Veff
130 5 55 300/100* 100 800 800
* for 98% value
CONSTRUCTION DATA Construction 2x2x0.6 3x2x0.6 4x2x0.6 6x2x0.6 8x2x0.6 10x2x0.6 20x2x0.6 24x2x0.6 30x2x0.6 40x2x0.6 80x2x0.6
163
Cu number [kg/km] 12 18 24 35 46 58 116 138 172 229 455
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C.
Diameter [mm]
Mass [kg/km] 6.0 7.5 8.0 9.0 9.5 10.5 13.0 14.0 15.0 17.0 22.5
45 60 70 90 110 125 210 245 290 365 665
TC 88 K (EK) Switchboard halogen free cables Standard: JUS N.C4.140 i PTT Vesnik br. 16 / 86
CONSTRUCTION Conductor: soft annealed tinned copper wire of 0.5; 0.6 (mm) diameter. Insulation: halogen-free, fire retardant polymer. Twisting elements: pairs, triples, quads, quintuples. Cable core: concentric layer stranded. Core wrapping: thermoplastic tapes in several layers. For TC 88 K Sheath: grey halogen-free, fire retardant polymer with low smoke emission in case of fire. For TC 88 EK Screen: laminated aluminium foil with a tinned copper drain wire baing longitudinally applied under it. Sheath: grey halogen-free, fire retardant polymer with low smoke emission in case of fire.
APPLICATION
For internal connections in telephone exchanges and signalling units. Cable do not spread flame (DIN VDE 0472 T804C).
ELECTRICAL CHARACTERISTICS Characteristic
164
Unit
Lop resistance, max
ohm/km
Insulation resistance, min
G ohm km
Mutual capacitance, max
nF/km
Capacitance unbalance k19, max
pF/500 m
Dielectric strength
wire/ wire
V
Standard
Value 0.5 [mm]
0.6 [mm]
JUS
190
128
IEC
195.6
135.8
JUS
200
200
IEC
500
500
JUS
100
100
IEC
120
120
JUS
-
-
IEC
400
400
JUS
800
800
IEC
1000
1000
CONSTRUCTION DATA Construction 1x2 2x2 3x2 5x2 6x2 7x2 10x2 15x2 20x2
conductor 0,4 [mm] Cu number Diameter Mass [kg/km] [mm] [kg/km] 4 5.0 30 8 5.5 40 12 6.5 50 20 7.5 65 24 8.0 75 28 8.5 80 39 9.5 105 59 11.0 140 78 12.0 175
conductor 0,6 [mm] Cu number Diameter Mass [kg/km] [mm] [kg/km] 6 5.0 35 11 6.0 45 17 6.5 55 28 8.0 75 34 8.5 85 39 9.0 100 57 10.0 125 84 11.5 175 113 13.0 235
Construction 30x2 40x2 50x2 60x2 70x2 80x2 100x2 1x3 3x3 5x3 7x3 10x3 15x3 20x3 25x3 30x3 35x3 40x3 50x3 60x3 70x3 80x3 100x3 1x4 3x4 5x4 7x4 10x4 15x4 20x4 25x4 30x4 35x4 40x4 50x4 60x4 70x4 80x4 100x4 1x5 3x5 5x5 7x5 10x5 15x5 20x5 25x5
conductor 0,4 [mm] Cu number Diameter Mass [kg/km] [mm] [kg/km] 117 14.5 265 156 16.5 335 195 18.0 420 234 19.5 490 273 20.5 560 314 22.0 630 393 24.5 790 6 5.0 35 18 7.5 60 30 8.5 85 41 9.5 110 59 11.0 145 88 13.0 210 118 14.5 260 148 15.5 315 177 17.0 370 206 18.0 420 236 19.0 470 295 20.5 570 354 22.5 670 413 24.5 820 472 26.0 920 590 29.0 1125 8 5.5 35 24 8.0 75 39 9.5 105 56 10.5 135 79 12.0 180 118 14.5 265 158 16.5 335 198 18.0 420 237 19.5 490 276 21.0 560 316 22.0 630 395 24.5 790 474 26.5 925 553 29.0 1090 632 30.5 1225 790 33.5 1495 10 6.0 40 30 9.0 90 50 10.5 125 69 11.5 160 99 14.0 230 148 16.5 320 198 19.0 425 248 20.5 515
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C. Smallest bending radius at laying, 7,5 D (D – diameter cable).
conductor 0,6 [mm] Cu number Diameter Mass [kg/km] [mm] [kg/km] 170 15.5 325 226 17.5 415 283 19.0 505 340 20.5 595 396 22.0 705 452 24.0 815 565 26.5 995 9 5.5 35 25 7.5 70 41 9.0 100 59 10.0 130 85 12.0 175 128 13.5 255 170 15.5 325 213 16.5 390 255 18.5 475 298 19.5 545 340 20.5 610 425 22.5 745 510 25.0 900 595 26.5 1030 680 28.5 1190 850 31.5 1455 11 5.5 40 34 8.5 85 57 10.0 125 80 11.0 165 113 13.5 235 170 15.5 325 226 18.0 435 283 19.5 525 339 21.0 615 396 22.5 705 452 24.0 815 565 26.5 990 678 29.0 1195 791 31.0 1370 904 33.0 1545 1130 36.5 1930 14 6.0 45 42 9.5 105 71 11.0 150 99 12.5 210 140 15.0 285 212 18.0 415 283 20.0 530 353 22.0 640
165
TZ 88 E (GE) Low-frequency halogen free terminal cable Standard: PSN 303/95 Radni napon: do 225 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.6 (mm) diameter. Insulation: halogen-free, fire retardant polymer. Twisting elements: star quad. Cable core: group or concentric layer stranded. Core wrapping: thermoplastic tapes in several layers. Screen: Al tape wrapping with a copper drain wire being longitudinally applied under it. Sheath: halogen-free, fire retardant polymer with low smoke emission in case of fire.
For the connection of terminal continuation and main distribution frame.
APPLICATION
Cable do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Characteristic
166
Loop resistance, Individual value Average value max Insulation resistance, min Mutual capacitance, max. k1 za 100% k1 za 90% Capacitance k9-12 za 100% unbalance, k9-12 za 90% max e1-e2 za 100 % e1-e2 za 90 % Dielectric wire/wire wire/screen strength Direct voltage stability voltage, time 10x24 h
Unit
Value
ohm/km ohm/km G ohm km nF/km pF/100 m pF/100 m pF/100 m pF/100 m pF/100 m pF/100 m Veff Veff
130 126 200 100 100 50 100 50 300 150 500 2000
V
110+5
CONSTRUCTION DATA Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
25X4x0.6
266
18.0
480
50X4x0.6
588
24.5
915
Constrution nx4xd
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C. Smallest bending radius, 7,5 D (D – diameter cable).
THI Telephone halogen free installation wire Standard: PSN
CONSTRUCTION Conductor: soft annealed copper wire of 0.6; 0.8 (mm). Insulation: Halogen-free, fire retardant, low smoke emission polymer. Twisting elements: Pairs, triples, quads.
For shunting and wiring of cable distributors, signal units and for the connention of loudspeakers. Substitute TI 20.
APPLICATION
Wire do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS
Characteristic
Value
Unit
Conductor resistance at 20 °C, max
ohm/km
Insulation rasistance at 60 °C, min
M ohm km
Dielectric strength (1 minute)
Veff
0.6 [mm]
0.8 [mm]
63.0
35.5
1
1
2000
2000
CONSTRUCTION DATA conductor 0,6 [mm] Construction
167
conductor 0,8 [mm]
Cu number
Diameter
Mass
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
[kg/km]
[mm]
[kg/km]
1x
2.8
1.4
4.5
5
1.8
8.0
2x
5.6
2.8
9.0
10
3.6
16.0
3x
8.5
3.0
14.0
15
3.9
23.5
4x
11.4
3.4
18.0
20
4.3
31.0
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C. Smallest bending radius, 15 D (D – diameter installation wire).
THM Telephone halogen free switchboard installation wire Standard: PSN
CONSTRUCTION Conductor: soft annealed tinned copper wire of 0.6; 0.8; 1.0; 1.2 (mm) diameter. Insulation: halogen-free, fire retardant, low smoke emission polymer. Insulation colour: red, gray, black, orange, blau, yellow, brawn, green.
For internal connections in telecommunication devices or for their connection. Substitute TM 20.
APPLICATION
Wire do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Characteristic
Value
Unit
Conductor resistance at 20 °C, max Insulation rasistance at 60 °C, min Dielectric strength (1 minute)
ohm/km M ohm km Veff
0.6[mm]
0.8[mm]
1.0[mm]
63 1 2000
35.5 1 2000
23 0.8 2000
1.2[mm] 16 0.8 2000
CONSTRUCTION DATA Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
1x0.6
2.7
1.4
4.5
1x0.8
4.8
1.8
8.0
1x1.0
7.5
2.0
11.0
1x1.2
11.0
2.2
14.0
Construction
168
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70 0C. Smallest bending radius, 15 D (D – diameter installation wire).
THN
J-HH
Halogen free installation cable Standard: PSN Working voltage: up to 300 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.6; 0.8 (mm) for twocore; 0.6 (mm) for multi-core. Insulation: halogen-free, fire retardant polymer. Twisting elements: pairs, star quad. Cable core: concentric layer stranded. Core wrapping: thermoplastic tape. Sheath: halogen-free, fire retardant, low smoke emission polymer.
APPLICATION
For installation line or introducing several lines into buildings. Substitute TI 44 and J-YY. Cable do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Value for Characteristic
Unit
two-cores 0.6[mm] 0.8[mm] 130 73.2 200 200 100 100
Conductor resistance, max ohm/km Insulation rasistance at 20°C, min M ohm Mutual cpacitance, max nF/km Capacitance unbalance, max pF/100 K1 m K9-12 Dielectric strength 800 wire/ wire Veff Operatig voltage, peak value 300 V * 20% value, but min. One value, may amount up to 500 pF ** 10 % value, but min. One value, may amount up to 300 pF
800 300
multicores 0.6[mm] 130 200
300* 100** 800 300
169
CONSTRUCTION DATA nx2xd 1x2x0.6 2x2x0.6 3x2x0.6 4x2x0.6 5x2x0.6 6x2x0.6 10x2x0.6 15x2x0.6 20x2x0.6 25x2x0.6 30x2x0.6 35x2x0.6 40x2x0.6 50x2x0.6
Cu
Diameter
Mass
[kg/km]
[mm]
[kg/km]
7 14 19 25 31 37 59 88 116 145 172 201 229 286
5.0 6.0 7.0 7.5 8.0 8.5 10.5 13.5 15.0 16.5 17.5 19.0 20.0 22.0
30 45 60 75 85 100 145 230 285 345 400 470 525 635
nx2(4)xd
Smallest bending radius, 7,5 D (D – diameter cable).
Diameter
Mass
[mm]
[kg/km]
70x2x0.6 80x2x0.6 100x2x0.6
401 455 568
26.0 27.5 30.5
875 980 1225
5X4x0.6 10X4x0.6 15X4x0.6 20X4x0.6 25X4x0.6 30X4x0.6 40X4x0.6 50X4x0.6
62 118 172 229 286 342 455 568
10.5 15.0 17.5 20.0 22.0 24.5 27.5 30.5
145 285 395 585 635 765 980 1220
1x2x0.8
7,5
6.0
45
n – number of the elements, d – nominal diameter of the conductor Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70°C.
Cu [kg/km]
THNE
J-H(St)H
Halogen free installation cable Standard: PSN Working voltage: do 300 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.6; 0.8 (mm) diameter. Insulation: halogen-free, fire retardant polymer. Twisting elements: pairs, except for two pairs being twisted to star quads. Cable core: concentric layer stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire being longitudinally applied under it. Sheath: halogen-free, fire retardant, low smoke emission polymer.
APPLICATION
For installation line or introducing several lines into buildings. Substitute J-Y(St)Y ... Lg. Cable do not spread flame (IEC 60332-3 method C).
ELECTRICAL CHARACTERISTICS Characteristic
Value
Unit 0.6 [mm] 130 100 100 300* 800 800
ohm/km Loop resistance, max M ohm km Insulation rasistance, min nF/km Mutual capacitance, max Capacitance unbalance k, min pF/100 m Dielectric wire/ wire Veff strength wire/screen Veff * Cable with two pairs can have value above 20 %. ** 20% value, but min one value, may amount up to 500 pF.
0.8 [mm] 73.2 100 100 300* 800 800
CONSTRUCTION DATA Construction
170
1x2x0.6 2x2x0.6 3x2x0.6 4x2x0.6 5x2x0.6 6x2x0.6 8x2x0.6 10x2x0.6 12x2x0.6 14x2x0.6 16x2x0.6 20x2x0.6 24x2x0.6 30x2x0.6 40x2x0.6 50x2x0.6 60x2x0.6 80x2x0.6 100x2x0.6 1x3x0.6
Cu
Diameter
Mass
[kg/km] 7 14 19 25 31 37 46 59 71 80 93 116 139 172 229 286 342 455 568
[mm] 6.5 7.5 8.5 9.0 9.5 10.0 11.0 12.0 13.0 13.5 14.5 15.5 16.5 18.5 21.0 23.0 25.0 28.0 31.5
[kg/km] 50 65 85 95 110 125 150 175 200 225 245 295 340 425 535 645 775 990 1235
9.4
7.0
Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70°C. Smallest bending radius, 7,5 D (D – diameter cable).
55
Construction 1x2x0.8 2x2x0.8 3x2x0.8 4x2x0.8 5x2x0.8 6x2x0.8 8x2x0.8 10x2x0.8 12x2x0.8 14x2x0.8 15x2x0.8 16x2x0.8 20x2x0.8 24x2x0.8 30x2x0.8 40x2x0.8 50x2x0.8 60x2x0.8 80x2x0.8 100x2x0.8 1x3x0.8
Cu
Diameter
Mass
[kg/km] 12 25 27 45 53 65 85 104 125 147 157 166 206 246 307 407 508 608 809 1010 16
[mm] 7.5 9.0 10.0 11.0 11.5 12.5 13.5 14.5 15.5 16.5 17.0 17.5 19.5 21.0 23.0 26.5 28.5 31.5 35.5 39.0 8.0
[kg/km] 65 90 115 140 160 180 220 260 300 340 360 380 470 550 660 870 1050 1260 1520 1970 70
THNE FE 20
JE-H(St)H FE20
Halogen free installation cable Standard: PSN Working voltage: up to 225 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.8 (mm) diameter. Barrier: tape Insulation: halogen-free, fire retardant polymer. Twisting elements: pairs, except for two pairs being twisted to star quads. Cable core: concentric layer stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire being longitudinally applied under it. Barrier: tape. Sheath: halogen-free, fire retardant, low smoke emission polymer.
APPLICATION
For installation line on place where is indispensable to reflect communication in fire long period of time. Also suitable as fire alarm cable. Cable do not spread flame (IEC 60332-3 method C), Insulation funcionality during 20 minutes (IED 60331).
ELECTRICAL CHARACTERISTICS Characteristic
Unit
Loop resistance, max Insulation resistance, min Mutual capacitance, max Capacitance unbalance k, max Dielectric wire/ wire strength wire/screen * 20 % valeu, but min one may be up to 400 pF.
Value
ohm/km M ohm km nF/km pF/100 m Veff Veff
73.2 100 100 200* 500 2000
171
CONSTRUCTION DATA nx2xd
Cu
Diameter
Mass
nx2xd
Cu
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
1x2x0.8
12
8.0
75
24x2x0.8
246
21.5
570
2x2x0.8
25
9.0
95
30x2x0.8
307
24.0
710
4x2x0.8
45
11.0
150
32x2x0.8
327
24.5
725
6x2x0.8
65
12.5
195
40x2x0.8
407
26.5
900
8x2x0.8
85
14.0
235
50x2x0.8
508
30.0
1115
10x2x0.8
104
15.0
275
60x2x0.8
608
32.0
1300
12x2x0.8
125
16.0
320
80x2x0.8
809
36.0
1720
16x2x0.8
166
18.5
415
100x2x0.8
1010
39.5
2025
20x2x0.8
206
20.0
495
n – number of the elements; d – nominal diameter of the conductor Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70°C. Smallest bending radius, 7,5 D (D – diameter cable).
THNE FE 180
JE-H(St)H FE180
Halogen free installation cable Standard: PSN Working voltage: up to 225 V
CONSTRUCTION Conductor: soft annealed copper wire of 0.8 (mm) diameter. Barrier: tape Insulation: halogen-free, fire retardant polymer. Twisting elements: pairs, except for two pairs being twisted to star quads. Cable core: concentric layer stranded. Core wrapping: thermoplastic tape. Screen: laminated aluminium foil with a copper drain wire being longitudinally applied under it. Barrier: tape. Sheath: halogen-free, fire retardant, low smoke emission polymer.
A APPLICATION AP PP PLLIIC CA AT TIIO ON N
For installation line on place where is indispensable to reflect communication in fire long period of time. Also suitable as fire alarm cable. Cable do not spread flame (IEC 60332-3 method C), Insulation funcionality during 20 minutes (IED 60331).
ELECTRICAL CHARACTERISTICS Characteristics
172
Unit
Value
Loop resistance, max Insulation resistance, min
ohm/km M ohm km
Mutual capacitance, max Capacitance unbalance k, max
nF/km
Dielectric strength
Veff
500
Veff * 20 % valeu, but min one may be up to 400 pF.
2000
73.2 100 100
pF/100 m
wire/ wire wire/screen
200*
CONSTRUCTION DATA nx2xd
Cu
Diameter
Mass
nx2xd
Cu
Diameter
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
[mm2]
[kg/km]
[mm]
[kg/km]
1x2x0.8
12
9.0
85
24x2x0.8
246
24.5
705
2x2x0.8
25
10.0
110
30x2x0.8
307
27.0
845
4x2x0.8
45
11.5
165
32x2x0.8
327
27.5
890
6x2x0.8
65
13.5
220
40x2x0.8
407
31.0
1110
8x2x0.8
85
15.0
275
50x2x0.8
508
34.0
1340
10x2x0.8
104
16.5
350
60x2x0.8
608
37.0
1535
12x2x0.8
125
18.0
390
80x2x0.8
809
41.5
2010
16x2x0.8
166
20.5
490
100x2x0.8
1010
46.0
2450
20x2x0.8
206
22.5
585
n – number of the elements; d – nominal diameter of the conductor Permissible environment temperatures: - at laying, from -5°C up to +50°C, - before and after laying, up to +70°C. Smallest bending radius, 7,5 D (D – diameter cable).
MGH Halogen free power shipboard cable Standard: DIN 89160 Nominal voltage: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Insulation: rubber compound based on hard ethylenepropylene rubber, (DIN 89159, HEPR). Filler: halogen free rubber compound/tape. Sheath: halogen free compound based on polyolefin (IEC 60092-359; SHF-1). Sheath colour, black.
MGCH Halogen free screened power shipboard cable Standard: DIN 89158 Nominal voltage: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Insulation: rubber compound based on hard ethylenepropylene rubber, (DIN 89159, HEPR). Filler: halogen free rubber compound/tape. Screen: braid of copper wires. Sheath: halogen free compound based on polyolefin (IEC 60092-359; SHF-1). Sheath colour, black.
FMGCH
173
Telecommunikation halogen free screened cable Standard: DIN 89159 Nominal voltage: 250 V
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Insulation: rubber compound based on hard ethylene-propylene rubber, (DIN 89159, HEPR). Twisting elements: pairs. Filler: tape. Screen: braid of copper wires. Sheath: halogen free compound based on polyolefin (IEC 60092359; SHF-1). Sheath colour, black.
APPLICATION
Used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Cable is halogen-free, does not spread fire and flame, with less corrosive gasses when burning and have low density smoke emission.
NFK MGH Halogen free power shipboard cable with insulation funcionality Standard: PSN Nominal voltage: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Barrier: mica tape. Insulation: based on hard EPR grade (DIN 89160, HEPR). Filler: compound without halogen. Sheath: without halogen, based on polyolefin (IEC 60092-359; SHF-2). Sheath colour, orange.
NFK MGCH Halogen free screened power shipboard cable with insulation funcionality Standard: PSN Nominal voltage: 0,6/1 kV
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Barrier: mica tape. Insulation: based on hard EPR grade (DIN 89160, HEPR). Filler: compound without halogen. Screen: braid of copper wires. Sheath: without halogen, based on polyolefin (IEC 60092-359; SHF-2). Sheath colour, orange.
NFK FMGCH 174
Telecommunication halogen free screened shipboard cable with insulation funcionality Standard: PSN Nominal voltage: 250 V
CONSTRUCTION Conductor: tinned copper conductor (DIN VDE 0295, class 2). Barrier: mica tape. Insulation: based on hard EPR grade (DIN 89160, HEPR). Twisting elements: pairs. Filler: compound without halogen. Screen: braid of copper wires. Sheath: without halogen, based on polyolefin (IEC 60092-359; SHF-2). Sheath colour, orange.
APPLICATION
Used for fixed laying on ships and off-shore units, use in all rooms and on open board, as power, signalling and control cables. Cable does not spread fire and flame, it is halogen-free, with less corrosive gasses when burning and have low density smoke emission. Cable keeps its function at least 180 minutes.
175
COAXIAL CABLES RG 50
177
RG 75
178
RG 50 Ω Coaxial cables Standard: MIL C-17/28 C, MIL C-17/74 C, PSN
CONSTRUCTION Conductor: Cu wire or stranded copper wires. Insulation: PE. Outer conductor: bare copper wires braid or tinned copper wires braid. Sheath: PVC compound or PE. RG 58 C/U Standard MIL C-17/28 C RG 213/U Standard MIL C-17/74 C RG 213/U/E Standard PSN 08 E040
APPLICATION
Coaxial cable with RG mark and characteristic impendence of 50Ω, is intended for general usage in professional telecommunication techniques and radio amateurism. During the transmission of VF signals through these cables it comes to generating of exceptionally small noise.
ELECTRICAL CHARACTERISICS Characteristic
Unit
Characteristic impedance Capacitance, max Working voltage, max Attenuation at 200C, max 50 MHz 100 MHz 200 MHz 400 MHz 450 MHz 800 MHz 860 MHz 1000 MHz
Value for RG 58 C/U
RG 213/U
Ω
50+/-2
pF/m
105,6
kV
dB/100m
RG213/U/E
1,4
3,7
3,7
12,0 18,5 28,0 45,0 75,0 91,8
5,5 7,5 11,0 15,7 22,5 29,5
5,5 7,5 11,0 15,7 22,5 29,5
CONSTRUCTION DATA Type
Conductor nxmm
Insulation
Outer conductor SnCu braid
Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
PVC
20.3
4,95
37,5
Sheath
RG 58 C/U
SnCu 9x0,18
PE - 2,95
RG 213/U
Cu 7x0,75
PE - 7,25
Cu braid 95%
PVC
82,0
10,3
153
RG 213/U/E
Cu 7x0,75
PE - 7,25
Cu braid 95%
PE
82,0
10,3
144,5
94%
Permissible temperature: - for PVC compound sheath: from -30 °C up to +70 °C, - for PE sheath: from -50 °C up to +70 °C.
177
RG 75 Ω Coaxial cable Standard: MIL C-17/28 B, MIL C-17/77 C, PSN
CONSTRUCTION Conductor: Cu wire or stranded copper wire. Insulation: PE. Outer conductor: bare copper wires braid or tinned copper wires braid. Sheath: PVC compound. RG 11 A/U Standard MIL C-17/28 B RG 216/U Standard MIL C-17/77 C RG 59 B/U-Cu Standard PSN 08 E070
APPLICATION
Coaxial cable with RG mark and characteristic impedance of 75Ω, is being used in a wide range of commercial electronics and highfrequent techniques and everywhere where is transmission of HF signals with less noise transmission needed.
ELECTRICAL CHARACTERISICS Characteristic
178
Working voltage, max Attenuation at 200C, max 50 MHz 100 MHz 200 MHz 400 MHz 450 MHz 800 MHz 860 MHz 1000 MHz
RG 11 A/U
RG 59 B/U-Cu
Ω
75+/-3
pF/m
67,5
Characteristic impedance Capacitance, max
Value for
Unit
kV
dB/100m
External disturbance attenuation
dB
RG 216/U
3,7
1,7
3,7
5,5 8,0 12,0 17,5 21,0 37,0 > 90
8,5 13,5 18,0 27,0 28,0 39,5 52,5 > 90
6,0 7,8 12,0 19,0 22,5 28,5 30,0 33,0 > 100
CONSTRUCTION DATA Cu number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
PVC
62,9
10,3
146
Cu braid 95%
PVC
25,5
6,15
56
2xCu braid 95+96%
PE
101,1
10,8
174
Conductor nxmm
Insulation
Outer conductor
Sheath
SnCu 7x0,40
PE - 7,25
Cu braid 96%
RG 59 B/U-Cu
Cu 1x0,58
PE - 3,7
RG 216/U
Cu 7x0,40
PE - 7,25
Type RG 11 A/U
Permissible temperature: - for PVC compound sheath: from -30 °C up to +70 °C, - for PE sheath: from -50 °C up to +70 °C.
179
OVERHEAD LINES Alumoveld Conductors
181
Protective ropes for transmission lines
187
AlMgSi Conductors Aluminium Conductors Al/steel Conductors Hard copper and bronze ropes
182
PP/O
188
183
X00-A
189
184
X00/O-A
190
186
СИП 3
191
XHP 48/O-A; XHE 49/O-A
192
ALUMOVELD CONDUCTORS Alumoveld conductor for overhead lines Standard: IEC 61089, IEC 61232 ASTM B 415, ASTM B 416
CONSTRUCTION Conductor: alumoveld wire. Type of the conductor: 20SA - 25 % Al in surface 27SA - 37 % Al in surface 30SA - 43 % Al in surface 40SA - 62 % Al in surface
APPLICATION
layer layer layer layer
wire wire wire wire
and and and and
75 63 57 38
% % % %
steel, steel, steel, steel,
84,80 63,86 57,47 43,10
Ωmm2/km Ωmm2/km Ωmm2/km Ωmm2/km
Conductor is suitable in case when required a high degree of safety conductor. Specific application is bridging the great natural barrier in one length, such as connecting islands, crosses the river, etc.
CONSTRUCTION DATA Type per IEC 61232 16-SA1A-7 (20SA) 42-SA1A-19 (20SA) 84-SA2-19 (27SA) 160-SA2-37 (27SA)
Construction
Cross section
Equivalent cross section
Diameter
Mass
[mm] 7 x 2,95 19 x 2,91 19 x 3,56 37 x 3,53
[mm2] 47,84 126,37 189,12 362,11
[mm2] 16 42 84 163
[mm] 8,85 14,55 17,80 24,70
[kg/km] 320 850 1150 2216
Calculated breaking strength, min
[kN] 64,32 155,54 204,20 391,00
Calculated electrical resistance, at 20°C, max
[Ω/km] 1,79527 0,68200 0,34370 0,18030
All layers are greased, except external. Fat drop point of 130°C. Permissible continuous conductor temperature is 125°C. Short (1 sec) permissible conductor temperature is 300°C. Type per ASTM B416 37 № 37 № 37 № 37 № 37 № 37 № 19 № 19 № 19 № 19 № 19 № 19 № 7№ 7№ 7№ 7№ 7№ 7№ 7№ 7№ 3№ 3№ 3№ 3№ 3№ 3№
5 6 7 8 9 10 5 6 7 8 9 10 5 6 7 8 9 10 11 12 5 6 7 8 9 10
AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG AWG
Construction
[mm] 37 x 4,62 37 x 4,11 37 x 3,36 37 x 3,26 37 x 2,91 37 x 2,59 19 x 4,62 19 x 4,11 19 x 3,36 19 x 3,26 19 x 2,91 19 x 2,59 7 x 4,62 7 x 4,11 7 x 3,36 7 x 3,26 7 x 2,91 7 x 2,59 7 x 2,30 7 x 2,05 3 x 4,62 3 x 4,11 3 x 3,36 3 x 3,26 3 x 2,91 3 x 2,59
Cross sections
[cmils] 1225000 971300 770300 610900 484400 384200 628900 498800 359500 313700 248800 197300 231700 183800 145700 115600 91650 72680 57590 45710 99310 78750 62450 49530 39280 31150
Diameter
Mass
[inč] 1,27 1,13 1,01 0,899 0,801 0,713 0,910 0,810 0,721 0,642 0,572 0,509 0,546 0,486 0,433 0,385 0,343 0,306 0,272 0,242 0,392 0,349 0,311 0,277 0,247 0,220
[lb/1000 ft] 2802 2222 1762 1398 1108 879 1430 1134 890 714 566 449 525 416 330 262 208 165 131 104 225 178 141 112 89 71
Calculated breaking strength, min
[lb] 142800 120200 100700 84200 66770 52950 73350 61700 51730 43240 34290 27190 27030 22730 19060 15930 12630 10020 7945 6301 12230 10280 8621 7260 5715 4532
Calculated electrical resistance, at 20°C
[Ω/1000 ft] 0,04247 0,05356 0,06754 0,08516 0,10740 0,13540 0,08224 0,10370 0,13080 0,16490 0,20790 0,26220 0,22640 0,28030 0,35350 0,44580 0,56210 0,70880 0,89380 1,12700 0,51770 0,65280 0,82320 1,03800 1,30900 1,65100
181
ALMgSi CONDUCTORS Conductor for overhead lines Standard: EN 50 182, IEC 61089 EN 50 183, IEC 104
CONSTRUCTION Conductor: rope of AlMgSi wires Material: ALMgSi alloy according to EN 1715-2, EN 50183, IEC 104 For conductor type Al2 Tensile strength, min 325 N/mm2 to ∅ 3,5 mm Tensile strength, min 315 N/mm2 for ∅ 3,5 - 5,0 mm Specific electric resistance, max 32,84 Ωmm2/km For conductor type Al3 Tensile strength, min 295 N/mm2 Specific electric resistance, max 32,53 Ωmm2/km
APPLICATION
Conductors Al2/Al3 and Al2F/Al3F (compressed conductors) are used for insulated conductors as overhead lines. Recommended for use in coastal areas, by reason they are resistant to salt mist, as well as in industrial zones where they are exposed to aggressive atmospheric chemicals.
CONSTRUCTION DATA for Al2
182
Cross section
Construction
[mm2] 16 25 40 63 100 125 160 200 250 315 400 450
[mm] 7 x 1,84 7 x 2,30 7 x 2,91 7 x 3,65 19 x 2,79 19 x 3,12 19 x 3,53 19 x 3,95 19 x 4,41 37 x 3,55 37 x 4,00 37 x 4,24
Diameter
Mass
[mm] 5,5 6,9 8,7 10,9 14,0 15,6 17,6 19,7 22,1 24,8 28,0 29,7
[kg/km] 51 80 127 200 319 399 511 639 799 1009 1281 1441
Calculated breaking strength, min
[kN] 6,0 9,4 15,1 23,1 37,8 47,2 58,6 73,2 91,5 115,3 146,4 164,7
Calculated electrical resistance, at 20°C, max
[Ω/km] 1,7896 1,1453 0,7158 0,4545 0,2877 0,2302 0,1798 0,1439 0,1151 0,0916 0,0721 0,0641
CONSTRUCTION DATA for Al3 Cross section
[mm2] 16-AL3 25-AL3 35-AL3 50-AL3 50-AL3 70-AL3 95-AL3 120-AL3 150-AL3 185-AL3 239-AL3 301-AL3 299-AL3 403-AL3 497-AL3 600-AL3
Construction
[mm] 7 x 1,70 7 x 2,14 7 x 2,52 7 x 3,02 19 x 1,83 19 x 2,17 19 x 2,52 19 x 2,84 37 x 2,27 37 x 2,52 37 x 2,87 37 x 3,22 61 x 2,50 61 x 2,90 61 x 3,22 61 x 3,54
Diameter
Mass
[mm] 5,10 6,42 7,56 9,06 9,15 10,9 12,6 14,2 15,9 17,6 20,1 22,5 22,5 26,1 29,0 31,9
[kg/km] 43,4 68,7 95,3 136,9 137,2 192,9 260,2 330,4 412,5 508,4 659,4 830,0 827,5 1113,6 1372,9 1659,3
Calculated breaking strength, min
[kN] 4,7 7,4 10,3 14,8 14,7 20,7 28,0 35,5 44,2 54,4 70,6 88,9 88,3 118,9 146,5 177,1
Calculated electrical resistance, at 20°C, max
[Ω/km] 2,0701 1,3064 0,9421 0,6560 0,6619 0,4707 0,3490 0,2748 0,2217 0,1799 0,1387 0,1102 0,1112 0,0826 0,0670 0,0555
ALUMINIUM CONDUCTORS Aluminium conductors for overhead lines Standard: DIN 48 201 Part 5 SRPS N.C1.302
CONSTRUCTION Conductor: rope of aluminium wires. Material: Aluminium purity 99,7 % according to EN 1715-2 type H13, SRPS C.D1.300 It is possible to produce compacted Al conductors. Compared to the conductor of the same outer diameter, it is provided increase of cross section about 20-25 % and higher throughput. Marking compacted conductor according to IEC 62219 is A1F.
APPLICATION
The conductor is used for overhead lines.
CONSTRUCTION DATA Cross section [mm2] 16 25 35 50 50 70 95 120 150 185 240 300 400 500 625 800 1000
Construction Diameter
[mm] 7 7 7 7 19 19 19 19 37 37 61 61 61 61 91 91 91
x x x x x x x x x x x x x x x x x
1,70 2,10 2,50 3,00 1,80 2,10 2,50 2,80 2,25 2,50 2,25 2,50 2,89 3,23 2,96 3,35 3,74
[mm] 5,1 6,3 7,5 9,0 9,0 10,5 12,5 14,0 15,8 17,5 20,3 22,5 26,0 29,1 32,6 36,9 41,1
Modulus of elasticity
Coefficient of linear expansion
[dN/mm2] [1/°Cx10-5] 6000 6000 6000 6000 5700 5700 5700 5700 5700 5700 5500 5500 5500 5500 5500 5500 5500
2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3 2,3
Cross-section calculated without an increase due to stranding. Specific electric resistance for aluminium is 28,264 Ωmm2/km.
Mass
Calculated breaking strength, min
Calculated electrical resistance at 20°C, max
[kg/km]
[kN]
[Ω/km]
43 66 94 135 133 181 256 322 406 500 670 827 1104 1379 1732 2218 2767
2,84 4,17 5,78 7,94 8,45 11,32 15,68 18,78 25,30 30,54 39,51 47,70 60,86 74,67 95,25 118,39 145,76
1,8017 1,1814 0,8336 0,5789 0,5954 0,4374 0,3087 0,2461 0,1961 0,1589 0,1192 0,0966 0,0723 0,0579 0,0463 0,0362 0,0290
183
Al/steel CONDUCTORS
ACSR
Aluminium conductor steel reinforced Standard: SRPS N.C1.315, IEC 61089, EN 50182, DIN 48 204, BS 215 part 2, ASTM B 232, CSA C-49.1, GOST 839-80
CONSTRUCTION Conductor: core, heavily galvanized steel wire, and above aluminium wires, grease. Material: heavily galvanized steel wire according to SRPS N.C1.701, IEC 888, EN 50189; aluminium according to SPPS N.C1.301, IEC 889, EN 50 889; grease according to EN 50326.
Conductor transmission lines, for different voltage levels, and temperature conditions, for different current and mechanical load.
APPLICATION
CONSTRUCTION DATA
Number x diameter wire
Cross section
184
Diameter
Modulus of elasticity
[mm]
[N/mm2]
Coefficient of linear expansion
Mass
Calculated breaking strength, min
Calculated electrical resistance, at 20°C, max
[kN]
[Ω/km]
aluminium
steel
[mm]
[mm]
16/2,5
6 x 1,80
1 x 1,80
5,4
79 500
1,92
62
5, 950
1,87930
25/4
6 x 2,25
1 x 2,25
6,8
79 500
1,92
97
9, 200
1,20280
35/6
6 x 2,70
1 x 2,70
8,1
79 500
1,92
140
12, 660
0,83530
44/32
14 x 2,00
7 x 2,40
11,2
107 900
1,50
372
45, 000
0,65730
[1/°Cx10-5] [kg/km]
50/8
6 x 3,20
1 x 3,20
9,6
79 500
1,92
196
17, 140
0,59460
50/30
12 x 2,33
7 x 2,33
11,7
105 000
1,53
378
44, 225
0,56440
70/12
26 x 1,85
7 x 1,44
11,7
75 500
1,89
284
26, 800
0,41300
75/80
18 x 2,30
19 x 2,30
16,1
127 500
1,33
834
106, 34
0,38740
95/15
26 x 2,15
7 x 1,67
13,6
75 500
1,89
283
35, 750
0,30580
95/55
12 x 3,20
7 x 3,20
16,0
105 000
1,53
712
80, 200
0,29920
105/75
14 x 3,10
19 x 2,25
17,5
107 900
1,50
891
108, 45
0,27360
120/20
26 x 2,44
7 x 1,90
15,5
75 500
1,89
494
45, 650
0,23740
120/70
12 x 3,60
7 x 3,60
18,0
105 000
1,53
901
100, 00
0,23640
125/30
30 x 2,33
7 x 2,33
16,1
80 400
1,78
591
57, 800
0,22590
150/25
26 x 2,70
7 x 2,10
17,1
75 500
1,89
605
55, 250
0,19390
170/40
30 x 2,70
7 x 2,70
18,9
80 400
1,78
794
76, 750
0,16820
185/30
26 x 3,00
7 x 2,33
19,0
75 500
1,89
746
66.225
0,15710
210/35
26 x 3,20
7 x 2,49
20,3
75 500
1,89
850
74, 950
0,13800
Number x diameter wire
Cross section
aluminium
steel
[mm]
[mm]
Diameter
Modulus of elasticity
[mm]
[N/mm2]
Coefficient of linear expansion
Mass
[1/°Cx10-5] [kg/km]
Calculated breaking strength, min
Calculated electrical resistance, at 20°C, max
[kN]
[Ω/km]
210/50
30 x 3,00
7 x 3,00
21,0
80 400
1,78
981
93, 900
0,13630
230/30
24 x 3,50
7 x 2,33
21,0
72 600
1,96
877
73, 100
0,12490
240/40
26 x 3,45
7 x 2,68
21,9
75 500
1,89
987
86, 460
0,11880
240/55
30 x 3,20
7 x 3,20
22,4
80 400
1,78
1107
104, 24
0,11970
265/35
24 x 3,74
7 x 2,49
22,4
72 600
1,96
1002
83, 050
0,10940
300/50
26 x 3,86
7 x 3,00
24,5
75 500
1,89
1236
107, 00
0,09400
305/40
54 x 2,68
7 x 2,68
24,1
68 700
1,93
1160
99, 400
0,09490
340/30
48 x 3,00
7 x 2,33
25,0
60 800
2,09
1180
92, 900
0,08520
350/80
30 x 3,85
19 x 2,30
26,9
78 500
1,80
1585
148, 99
0,08270
360/57
26 x 4,20
19 x 1,96
26,6
68 700
1,93
1444
125, 25
0,08010
380/50
54 x 3,00
7 x 3,00
27,0
68 700
1,93
1453
123, 10
0,07570
385/35
48 x 3,20
7 x 2,49
26,7
60 800
2,09
1344
104, 80
0,07480
435/55
54 x 3,20
7 x 3,20
28,8
68 700
1,93
1653
136, 45
0,06437
450/40
48 x 3,45
7 x 2,68
28,7
60 800
2,09
1561
120, 75
0,06437
490/65
54 x 3,40
7 x 3,40
30,6
68 700
1,93
1866
153, 10
0,05896
490/110
30 x 4,55
19 x 2,73
31,7
78 500
1,80
2221
208, 77
0,05924
495/35
45 x 3,74
7 x 2,49
29,9
58 900
2,09
1646
121, 80
0,05843
510/45
48 x 3,68
7 x 2,87
30,7
60 800
2,09
1778
136, 65
0,05657
550/70
54 x 3,60
7 x 3,60
32,4
68 700
1,93
2092
170, 60
0,05259
560/50
48 x 3,86
7 x 3,00
32,2
60 800
2,09
1954
148, 95
0,05142
570/40
45 x 4,02
7 x 2,68
32,2
58 900
2,09
1888
138, 00
0,05057
650/45
45 x 4,30
7 x 2,87
34,0
58 900
2,09
2171
155, 55
0,04420
680/85
54 x 4,00
19 x 2,40
36,0
66 700
1,94
2566
210, 06
0,04260
1045/45
72 x 4,30
7 x 2,87
43,0
54 000
2,17
3251
217, 89
0,02772
Grackle
54 x 3,78
19 x 2,77
34,0
68000
1,94
2290
191,78
0,04790
Parrot
54 x 4,25
19 x 2,55
38,3
68000
1,94
2901
237,15
0,03770
Cochin
12 x 3,37
7 x 3,37
16,9
107000
1,53
794
92,200
0,27060
Scoter
30 x 3,70
7 x 3,70
25,9
82000
1,78
1495
135,44
0,09490
Bear
30 x 3,35
7 x 3,35
23,5
82000
1,78
1224
11,50
0,10930
Bison
54 x 3,00
7 x 3,00
27,0
70000
1,93
1452
12,09
0,07573
Duck
54 x 2,69
7 x 2,69
24,2
70000
1,93
1164
96,80
0,09490
Condor
54 x 3,08
7 x 3,08
27,7
70000
1,93
1524
124,45
0,07191
185
HARD COPPER AND BRONZE ROPES Ropes, with increased breakout force, for overhead lines Standard: DIN 48 201 Part 2 DIN 48 200 Part 2 DIN 48 203 Part 2
CONSTRUCTION Conductor: copper or bronze, according to DIN 48 200 part 2 and DIN 48 203 part 2
For conductors of overhead lines, different voltage levels and temperature conditions, different current and mechanical load. The most common application is for the power supply rail.
APPLICATION
CONSTRUCTION DATA Cross section
186
Construction Diameter
Mass
Breaking strength Cu
Bz I
Bz II
Current rating Cu
Bz I
Bz II
[mm2]
nxd [mm]
[mm]
[kg/km]
0,5
7 x 0,30
0,90
4,1
0,20
0,24
0,29
0,75
7 x 0,38
1,14
6,7
0,32
0,39
0,47
1,0
7 x 0,43
1,29
9,1
0,42
0,50
0,60
1,5
7 x 0,52
1,56
13,2
0,61
0,73
0,87
2,5
7 x 0,67
2,01
22,0
1,01
1,22
1,45
4,0
7 x 0,85
2,55
35,4
1,62
1,96
2,33
6,0
7 x 1,05
3,05
54,0
2,48
2,99
3,56
10
7 x 1,35
4,05
90,0
4,18
4,95
5,88
90
85
75
16
7 x 1,70
5,10
143,0
6,63
7,85
9,33
125
115
100
25
7 x 2,10
6,30
219,0
10,1
11,98
16,26
160
150
130
35
7 x 2,50
7,50
310,0
14,3
16,97
20,17
200
185
160
50
7 x 3,00
9,00
447,0
20,6
23,97
28,39
250
235
200
50
19 x 1,80
9,00
438,0
20,2
23,88
28,39
250
235
200
70
19 x 2,10
10,50
597,0
27,4
32,51
38,64
310
285
245
kN
A
95
19 x 2,50
12,50
846,0
38,8
46,08
54,76
380
355
305
120
19 x 2,80
14,00
1061,0
48,72
56,68
67,57
440
410
350
150
37 x 2,25
15,70
1337,0
61,26
72,67
86,37
510
470
410
PROTECTIVE ROPES FOR TRANSMISSION LINES Compressed AlMgSi ropes type A2 Standard: IEC 61089, IEC 61232 IEC 104, IEC 888
CONSTRUCTION Conductor: core of alumoveld or of galvanized steel, outer layer of AlMgSi alloy, type 2. Material characteristics: AlMgSi alloy according to EN 1715-2, EN 50183, IEC 104 Tensile strength, min 295 N/mm2 Specific electric resistance, max 32,53 Ωmm2/km ALUMOVELD class 20SA according to IEC 61232 Specific electric resistance, max 84,80 Ωmm2/km Galvanized standard steel according to IEC 888 Specific electric resistance, max 191,57 Ωmm2/km
APPLICATION
Ropes are used to protect transmission lines from lightning and short circuit. Recommended for use in coastal areas, because it is resistant to salt fog, and in industrial areas where it is exposed to aggressive atmospheric chemicals.
CONSTRUCTION DATA for conductor 43.7-A2/SA1A-12/7; construction 7x2,10 SA1A + 12x2,10A2 Designation E αti S d C αtk tkr.tr. Iks Itr Prač msam Tk
Characteristic Modulus of elasticity Thermal coefficient of linear expansion Cross section Diameter Specific heat capacity Temperature coefficient of electrical resistance at 20°C Short (1 s) permissible temperature Short permissible current at 1 s Persistent permissible current at 80 0C Calculated breaking strength Longitudinal mass with fat Dropping point fat, min
Value 9568 16,76x10-6 65,81 10,50 0,670959 0,0036 160 5,953 222 41,36 279,5 130
(daN/mm2) (1/°C) (mm2) (mm) (kJ/kg°C) (1/°C) (°C) (kA) (A) (KN) (kg/km) (°C)
All layers are greased, except layer.
conductor 36.5-A2/S1A-12/7; construction 7x2,10 S1A + 12x2,10A2 Designation E αti Sp Sp d C αtk tkr.tr. Prač msam Tk
Characteristic Modulus of elasticity Thermal coefficient of linear expansion Cross section outer layer Cross section core Diameter Specific heat capacity Temperature coefficient electrical resistance at 20 °C Short (1 s) permissible temperature Calculated breaking strength Longitudinal mass with fat Dropping point fat, min
All layers are greased, except outer.
Value 10232 15,55x10-6 41,56 24,25 10,50 0,6230 0,00418 160 42,95 310,4 130
(daN/mm2) (1/°C) (mm2) (mm2) (mm) (kJ/kg°C) (1/°C) (°C) (KN) (kg/km) (°C)
187
PP/O Insulated overhead line Standard: SRPS N.C3.315 Nominal voltage: 500 V Test voltage: 2 kV
CONSTRUCTION Conductor: annealed copper wire or rope class 2, according to SRPS N.C0.015. Insulation: PVC compound. Core: cores are stranded together. Filler: no vulcanized rubber compound layer over the core. Supporting element Supporting rope: rope consists of galvanized steel wire, whose minimum tensile strength is 1300 N/mm2. Sheath: PVC compound layer which covers the core and supporting rope. Sheath colour black.
In the open air for public illumination (lamps caring is possible), for air household connections, site temporary connections, and so on. On pillars, support brackets or steel constructions. Installation with the bearing conductor is made in accordance with the Regulation on technical standards for electrical installations of low voltage.
APPLICATION
CONSTRUCTION DATA
188
nxq
noxqo
2x1,5 2x2,5 2x4 2x6 2x10 2x16 2x25 2x35 3x1,5 3x2,5 3x4 3x6 3x10 3x16 3x25 3x35
19x0,6 19x0,6 19x0,6 19x0,6 19x0,8 19x0,8 19x0,8 19x1,0 19x0,6 19x0,6 19x0,6 19x0,6 19x0,8 19x0,8 19x1,0 19x1,0
Cu
Height x width
Mass
[kg/km]
[mm]
[kg/km]
29 48 77 115 192 308 480 672 43 72 115 173 288 461 720 1008
9,3x17,2 10,5x19,4 11,2x18,8 12,6x21,6 16,1x26,6 19,3x29,6 23,2x33,6 26,5x39,0 9,7x17,6 10,8x18,1 12,5x20,4 14,1x23,4 17,2x27,5 20,5x30,8 25,1x36,9 28,2x40,7
209 256 296 360 597 863 1234 1660 227 278 365 468 729 1027 1572 2004
nxq
noxqo
4x1,5 4x2,5 4x4 4x6 4x10 4x16 4x25 4x35 5x1,5 5x2,5 5x4 5x6 5x10 5x16 5x25 5x35
19x0,6 19x0,6 19x0,6 19x0,6 19x0,8 19x0,8 19x1,0 19x1,2 19x0,6 19x0,6 19x0,6 19x0,8 19x0,8 19x1,0 19x1,2 19x1,2
Cu
Height x width
Mass
[kg/km]
[mm]
[kg/km]
58 96 154 230 384 614 960 1344 72 120 192 288 480 768 1200 1680
10,4x18,3 11,9x19,8 14,0x23,3 15,2x24,5 18,6x29,0 22,3x32,6 27,4x39,9 30,8x44,2 11,2x19,0 12,8x20,7 15,2x24,5 16,5x26,8 20,3x30,6 24,9x36,6 30,0x43,5 34,1x47,6
253 323 442 515 800 1180 1891 2476 280 364 504 672 900 1521 2281 2963
n – number of the wires, q – nominal cross section of the conductor, no – number of the wires in supporting element, do – diameter of the wire in supporting element Permissible temperature of the conductor: - operating temperature (constant load), max +70°C, - in short circuit (max 5 s), max +160°C. Permissible environment temperature: at laying, from +5°C up to +50°C.
X00/A Insulated overhead line Standard: SRPS N.C5.250 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3 kV
CONSTRUCTION Conductor: strand made from aluminium wires. Insulation: XLPE compound. Core: wires are bundle stranded. Wire marking: the cores of the phase conductors are marked with numbers: 1,2,3. Neutral supporting core has got a triangular bulge along the whole length.
APPLICATION
Cable is used in distributive low-voltage air networks in urban areas. Cable is intended for supply of facilities and villages of temporary and permanent character. It can use for air household connections. It can be placed on concrete, steel or wooden poles, the console attached to the facade of the building, next to the facade, onto wooden or steel construction.
CONSTRUCTION DATA nxq
Al number
Diameter
Mass
[kg/km]
[mm]
[kg/km]
2x16
93
15.7
136
2x25
145
18.4
208
4x16
186
18.9
273
4x25
290
22.2
415
n – number of the wires, q – nominal cross section of the conductor Permissible temperature of the conductor: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min -20°C. Smallest bending radius at bundle laying: - for cable - 14D (D - diameter cable), - for core - 6d (d - diameter core). Smallest bending radius after laying: - for cable - 6D (D - diameter cable), - for core - 4d (d - diameter core).
189
X00/O-A Insulated overhead line Standard: SRPS N.C5.250 Nominal voltage U0/U: 0,6/1 kV Test voltage: 3 kV for phase conductor; 2 kV for public illumination conductor
CONSTRUCTION Conductor: - phase conductor and public illumination conductor: rope consists of aluminium wires, - supporting neutral conductor: rope of aluminium alloy AlMgSi. Insulation: XLPE for each element of the bundle. Bundle: stranded cores around neutral conductor. Core marking: - the cores of the phase conductors are marked with numbers: 1,2,3. - neutral supporting core has got a triangular bulge along the whole length. - public illumination cores are marked by the identifications R1 and R2.
APPLICATION
Cable is used for distributive low-voltage air networks in urban areas. Cable is intended for supply of remote facilities and villages of temporary and permanent character. It can use for air household connections. Reduces the risk of short circuit due to contact with the conductor, vault, it is easy to set and requires no cutting of trees along the route. It can be placed on concrete, steel or wooden poles; the console attached to the facade of the building, next to the facade, the wooden or steel construction.
CONSTRUCTION DATA 3 x q + qo+ n x q 1 [mm2]
190
3X25+ 3X25+ 3X25+ 3X35+ 3X35+ 3X35+ 3X50+
Mass [kg/km]
70 70+1x16 70+2x16 70 70+1x16 70+2x16 70
597 665 733 710 779 847 845
3 x q + qo + n x q 1 [mm2] 3X50+ 3X50+ 3X70+ 3X70+ 3X70+ 3X70+ 3X70+
70+1x16 70+2x16 70 70+1x16 70+2x16 70+1x16 70+2x16
Mass [kg/km] 913 981 1064 1132 1200 1168 1272
q – nominal cross section phase conductor, qo – nominal cross section neutral conductor, n – number wires for public illumination, q1 – nominal cross section conductor for public illumination Permissible temperature of the conductor: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min -20°C. Smallest bending radius at bundle laying: - for bundle with q ≤ 50 mm2 - 6 D (D – diameter bundle), - for bundle with q = 70 mm2 - 9 D (D - diameter bundle), - for wire - 4 d(d1) (d – diameter wire phase conductor, d1 - diameter wire public illumination). Smallest bending radius during installation: - for bundle with q ≤ 50 mm2 - 14 D (D – diameter bundle), - for bundle with q = 70 mm2 - 9 D (D - diameter bundle), - for wire - 6 d(d1) (d – diameter wire phase conductor, d1 - diameter wire public illumination).
СИП 3 Insulated overhead line Standard: ГОСТ Р 52373 Nominal voltage U0/U: 12/20 kV
CONSTRUCTION Conductor: aluminium alloy rope. Insulation: XLPE compound.
Single wire insulated conductor for the transfer of energy in the air circuit lines
APPLICATION CONSTRUCTION DATA
Construction [mm2]
Number wires in conductor
Diameter
Mass
Breaking strength
Electrical resistance at 20°C
[mm]
[kg/km]
min [kN]
max [Ω/km]
1 x 50
7
13,5
218
14,2
0,720
1 x 70
7
14,9
283
20,6
0,493
1 x 95
7
16,4
375
27,9
0,363
1 x 120
19
18,2
452
35,2
0,288
1 x 150
19
19,6
544
43,4
0,236
Permissible temperature of the conductor: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C. Permissible environment temperature: - at laying and handling, min -20°C, - after laying, min –50°C. Smallest bending radius: 10 D (D – diameter cable).
191
XHP 48/O-A; XHE 49/O-A Cable for overhead lines Standard: SRPS N.C5.230 Nominal voltage U0/U: 3.6/6kV; 6/10kV; 12/20kV; 20/35kV Test voltage: 9kV; 15kV; 30kV; 50kV
CONSTRUCTION Phase conductor Conductor: compacted multi-wire aluminium conductor class 2 according to SRPS N.C0.015. Inner semi-conductive layer: thermo stabile material. Insulation: XLPE compound. Outer semi-conductive layer: semi-conductive layer made from thermo stable material with sheath made from wrapped semi-conductive tape in case of XHP 48/O-A type of cable or made from semi-conductive swelling tape in case of XHE 49/O-A type of cable. Electrical protection: wrapped copper wire with contra-helical copper tape. Separator: polyester tape in case of XHP 48/O-A type of cable, and waterproof insulating swelling tape in case of XHE 49/O-A type of cable. Sheath: PVC compound for XHP 48/O-A type of cable; PE compound for XHE 49/O-A type of cable. Sheath colour: black. Supporting element Rope: Zinc-plated steel rope, 50 mm2 nominal cross-section, according to SRPS C.H1.061. Minimal tensile strength: 72,11kN, elasticity module: 17500daN/mm2. Rope diameter: 9mm. Rope is covered with black polyethylene layer. Diameter of the covering: 12 mm.
Cable is used instead of overhead lines in rural networks, in areas with intensive object and traffic constructions, when the problems of safety lengths arise from limited areas. The cable is laid on the pillars of the air network. It can be laid partially in earth where that is necessary.
APPLICATION
CONSTRUCTION DATA
192
3,6/6 kV n x q/q1+ qo [mm2]
Al
Cu
[kg/km] [kg/km]
6/10 kV
12/20 kV
20/35 kV
Diameter
Mass
Diameter
Mass
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
3x1x25/10+50
216
360
41
1632
45
1846
-
-
-
-
3x1x 35/10+50
306
360
45
1800
50
2027
58
2660
-
-
3x1x 50/16+50
435
546
50
2207
54
2449
62
2961
78
4016
3x1x 70/16+50
609
546
52
2494
56
2750
65
3263
82
4469
3x1x 95/16+50
828
546
56
2841
60
3252
69
3715
86
4921
3x1x 120/16+50
1044
546
60
3127
65
3413
73
4016
88
5373
3x1x 150/25+50
1305
856
62
3715
67
4016
78
4770
93
5976
q – nominal cross section of the conductor, q1 – nominal cross section of the electrical protection, qo – nominal cross section of the supporting element Permissible temperature of the conductor: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C, - short-term in emergency up to +130°C. Permissible environment temperature: - XHP 48/O-A, at laying, min -5°C; at laying, for bundles, min -40°C; - XHE 49/O-A, at laying, min -20°C; at laying, for bundles, min -50°C. Smallest bending radius: 15 D (D – diameter cable).
193
METAL PRODUCTS WIRE OF ALUMINIUM COPPER WIRE
TINNED COPPER WIRE ALUMINIUM CONDUCTORS COPPER CONDUCTORS
201
197
BRAIDED COPPER ROPES CONDUCTORS FOR MEASURING TRANSFORMERS FLAT BRAIDS
198
BRASS WIRE
204
199
WIRE FOR EROSIMATE
205
195 196
202
203
WIRE OF ALUMINIUM Round wire for different purposes Standard: EN 60889, DIN 48 203 Part 5, ASTM B 230 IEC 889, SRPS N.C1.301, GOST 6132, BS 2627
CONSTRUCTION Conductor: wire of aluminium Material: Aluminium purity of 99,95 - 99,97 % EN 1715 - 2, SRPS N.C1.300, GOST 13843, ASTM B 233
Wire is intended for the cable industry, for the transmission line conductors, as well as products for other purposes (rivets, clips for the slaughter industry, antennas, network ...)
APPLICATION
CONSTRUCTION DATA
Diameter wire
Tolerance
Tensile strength
[mm]
± [mm]
[N/mm2]
0,2 – 1,0
0,01
200 – 160
1,0 – 5,0
0,01
160 – 140
5,0 – 9,4
0,02
140 – 100
195
COPPER WIRE Round copper wire for different purposes Standard: EN 13 602, DIN 40 500 Part 4 Copper: DIN 1787, SRPS C.D6.400
CONSTRUCTION Conductor: copper wire Material: Oxygen free copper purity of 99,95 Conductance 58 Sm/mm2
APPLICATION
For protective earthing of electrical networks, electrical appliances, electrical machinery and automobile industry.
CONSTRUCTION DATA
196
Electrical Elongati resistanc on e at 20°C
Diamet er
Tolerance
Tensile strength
[mm]
± [mm]
[N/mm2]
[%]
0,15
0,003
210-280
0,18
0,003
0,20
Electrical Elongati resistanc on e at 20°C
Diamet er
Tolerance
Tensile strength
max [Ω/km]
[mm]
± [mm]
[N/mm2]
[%]
max [Ω/km]
15
975,6
0,90
0,007
210-270
28
27,10
210-280
21
677,5
0,95
0,009
210-270
28
24,32
0,003
210-280
21
548,8
1,00
0,010
210-270
28
21,95
0,21
0,003
210-280
21
497,7
1,12
0,010
210-270
28
17,50
0,25
0,004
210-280
21
351,2
1,20
0,010
210-270
28
15,24
0,26
0,004
210-280
21
324,7
1,30
0,010
210-270
28
13,00
0,30
0,004
210-280
22
243,9
1,36
0,010
210-270
28
11,87
0,31
0,004
210-280
22
228,4
1,38
0,010
210-270
28
11,53
0,35
0,004
210-270
24
179,2
1,50
0,010
210-270
30
9,756
0,38
0,004
210-270
24
152,0
1,60
0,010
210-270
30
8,574
0,40
0,005
210-270
25
137,2
1,74
0,010
210-270
30
7,250
0,41
0,005
210-270
25
130,6
2,00
0,010
210-270
30
5,487
0,45
0,005
210-270
25
108,4
2,23
0,010
210-270
30
4,414
0,50
0,005
210-270
26
87,80
2,76
0,010
210-270
30
2,882
0,60
0,005
210-270
26
60,97
3,00
0,010
210-260
30
2,439
0,61
0,005
210-270
26
59,97
3,55
0,010
210-260
33
1,742
0,70
0,005
210-270
26
44,80
4,51
0,010
210-260
34
1,079
0,80
0,005
210-270
26
34,30
5,18
0,010
210-260
35
0,818
TINNED COPPER WIRE Round tinned copper wire for different purposes Standard: DIN 40 500 part 5, EN 13602 Copper: DIN 1787, SRPS C.D6.400 Tin: EN 610, DIN 1704
CONSTRUCTION Conductor: tinned copper wire Material: Oxygen free copper purity of 99,95 % with electrolytic plated tin purity of 99,95 %
APPLICATION
For cable purposes.
industry,
electronics,
electro
technical
and
other
CONSTRUCTION DATA
Electrical Elongati resistanc on e at 20°C
Diamet er
Tolerance
Tensile strength
[mm]
± [mm]
[N/mm2]
[%]
0,15
0,003
210-290
0,18
0,003
0,20
Electrical Elongati resistanc on e at 20°C
Diamet er
Tolerance
Tensile strength
max [Ω/km]
[mm]
± [mm]
[N/mm2]
[%]
15
1019,7
0,90
0,005
210-270
28
28,3
210-290
15
708,1
1,00
0,010
210-270
30
22,9
0,003
210-290
20
573,6
1,12
0,010
210-270
30
18,3
0,21
0,003
210-290
20
520,3
1,20
0,010
210-270
30
15,9
0,25
0,004
210-290
20
367,1
1,30
0,010
210-270
30
13,6
0,26
0,004
210-290
20
339,4
1,36
0,010
210-270
30
12,4
0,30
0,004
210-270
22
254,9
1,50
0,010
210-270
32
10,2
0,31
0,004
210-270
22
238,7
1,60
0,010
210-270
32
8,96
0,35
0,004
210-270
22
187,3
1,76
0,010
210-270
32
7,41
0,38
0,004
210-270
22
158,9
2,23
0,010
210-270
30
4,61
0,40
0,005
210-270
24
143,4
2,76
0,010
210-270
32
3,01
0,50
0,005
210-270
25
91,8
3,55
0,010
210-270
34
1,82
0,60
0,005
210-270
27
63,7
4,12
0,020
210-270
34
1,35
0,70
0,005
210-270
27
46,8
5,18
0,020
210-270
34
0,855
0,80
0,005
210-270
28
35,8
6,00
0,020
210-270
35
0,637
max [Ω/km]
The thickness of tin coating is: for class V1 – no requirement; for class V2 – from 0,4 up to 0,8 µm; for class V3 – from 1,0 up to 2,0 µm; for class V4 – 3,0 µm; for class V5 – 6,0 µm. Electrical resistance of conductor is given for class V1.
197
ALUMINIUM CONDUCTORS Compressed aluminium ropes class 2 Standard: EN 60 228 class 2, SRPS N.C0.015 class 2 NFC 32-321
CONSTRUCTION Conductor: rope of aluminium wire Material: Aluminium purity 99,7 % according to EN 1715-2, SRPS C.D1.300
The conductors are intended for cable industry.
APPLICATION CONSTRUCTION DATA
198
Cross section
Construction
Diameter
Mass
Electrical resistance, at 20°C, max
[mm2]
[mm]
[mm]
[kg/km]
[Ω/km]
16
7 x 1,70
4,75
42
1,91
25
7 x 2,20
5,90
67
1,20
35
7 x 2,55
6,95
94
0,868
50
7 x 3,00
8,15
135
0,641
70
12 x 2,75
9,90
189
0,443
95
18 x 2,68
11,40
256
0,320
120
18 x 3,00
12,90
324
0,253
150
18 x 3,34
14,00
405
0,206
185
35 x 2,65
15,80
499
0,164
240
35 x 3,05
18,10
648
0,125
300
34 x 3,65
20,40
810
0,100
400
55 x 3,25
24,50
1080
0,0778
500
61 x 3,25
27,90
1350
0,0605
COPPER CONDUCTORS Stranded copper and tinned copper conductors class 2, 5 and 6 Standard: EN 60228, SRPS N.C0.015, IEC 228, NFC 32-510, GOST 22 483, BS 6360
CONSTRUCTION Conductor: rope of copper or tinned copper wires. Material: Copper purity of 99,95 % Tin purity of 99,95 %
APPLICATION
Copper conductors are intended for the cable industry, class 2 (compacted conductors), 5 (flexible conductors) and 6 (very flexible conductors).
CONSTRUCTION DATA Cross section 2
[mm ] 0,5
0,75
1
1,5
2,5
4
6
10
16
25
Construction N x n x d [mm] 28 x 0,15 16 x 0,20 7 x 0,32 40 x 0,15 23 x 0,20 7 x 0,37 54 x 0,15 30 x 0,20 7 x 0,43 80 x 0,15 44 x 0,20 28 x 0,25 7 x 0,52 7 x 19 x 0,15 74 x 0,20 46 x 0,25 7 x 0,67 7 x 32 x 0,15 3 x 40 x 0,20 .74 x 0,25 52 x 0,30 7 x 0,85 76 x 0,30 7 x 48 x 0,15 7 x 26 x 0,20 3 x 38 x 0,25 7 x 1,05 7 x 78 x 0,15 7 x 44 x 0,20 7 x 19 x 0,30 7 x 11 x 0,40 7 x 1,36 12 x 72 x 0,15 7 x 70 x 0,20 12 x 18 x 0,30 7 x 17 x 0,40 19 x 1,05 7 x 1,75 19 x 72 x 0,15 12 x 62 x 0,20 19 x 26 x 0,25 19 x 18 x 0,30 7 x 27 x 0,40
Diameter
Mass
[mm] 0,92 0,90 0,87 1,08 1,15 1,11 1,26 1,30 1,29 1,55 1,55 1,55 1,56 2,05 1,95 2,00 2,01 2,58 2,83 2,45 2,40 2,55 2,95 3,16 3,20 3,30 3,10 4,6 4,2 4,3 4,2 4,1 5,7 5,4 5,5 5,4 5,1 4,8 6,5 6,4 7,5 6,8 6,5
[kg/km] 4 4 4 6 7 7 9 8 9 13 12 12 13 22 21 20 22 36 35 33 33 35 50 54 53 52 54 89 89 87 89 91 141 142 141 138 141 142 223 215 223 223 219
199
Cross section [mm2]
35
50
70
95
120
150
185
200 240
300
400 500 630
Construction N x n x d [mm] 19 x 1,39 7 x 2,22 27 x 72 x 0,15 19 x 56 x 0,20 27 x 18 x 0,30 12 x 22 0,40 19 x 1,55 7 x 2,60 37 x 72 x 0,15 27 x 56 x 0,20 19 x 52 x 0,25 19 x 36 x 0,30 19 x 20 x 0,40 19 x 1,80 7 x 3,00 61 x 64 x 0,15 27 x 78 x 0,20 27 x 50 x 0,25 19 x 28 x 0,40 19 x 2,15 12 x 2,78 61 x 84 x 0,15 37 x 78 x 0,20 37 x 50 x 0,25 27 x 26 x 0,40 19 x 2,54 18 x 2,73 37 x 7 x 25 x 0,15 48 x 78 x 0,20 37 x 25 x 0,40 37 x 2,05 18 x 3,00 61 x 3 x 44 x 0,15 61 x 77 x 0,20 37 x 56 x 0,30 37 x 31 x 0,40 37 x 2,27 18 x 3,36 61 x 3 x 54 x 0,15 61 x 42 x 0,30 37 x 37 x 0,40 37 x 25 x 0,50 61 x 1,97 37 x 2,58 34 x 2,88 61 x 7 x 30 x 0,15 61 x 54 x 0,30 61 x 31 x 0,40 48 x 38 x 0,40 37 x 33 x 0,50 61 x 2,24 34 x 3,25 61 x 7 x 38 x 0,15 61 x 68 x 0,30 61 x 38 x 0,40 61 x 25 x 0,50 61 x 2,54 61 x 33 x 0,50 19 x 36 x 0,85 61 x 2,90 19 x 91 x 0,60 61 x 3,25 127 x 38 x 0,40 127 x 2,50
Diameter
Mass
[mm] 6,2 6,0 9,0 8,0 8,1 8,2 7,5 6,95 10,2 9,5 9,8 9,5 10,2 8,4 8,15 12,2 11,0 11,6 11,7 10,4 9,9 13,9 13,2 13,3 13,2 11,9 11,4 15,5 15,0 15,8 13,3 12,9 17,8 17,0 17,0 16,5 15,7 14,2 19,7 19,0 18,2 19,5 17,5 16,6 15,9 22,7 21,7 22,0 21,3 21,7 19,0 18,4 25,0 24,4 24,5 24,2 21,3 27,7 34,4 24,5 31,6 27,6 34,0 30,9
[kg/km] 217 222 316 308 317 306 320 312 434 438 447 446 440 428 418 636 609 610 616 611 605 834 835 836 813 846 846 1068 1083 1071 1068 1068 1330 1360 1349 1328 1318 1326 1632 1668 1585 1673 1629 1630 1629 2115 2145 2094 2111 2134 2136 2135 2670 2701 2683 2758 2670 3641 3575 3560 4503 4450 5586 5607
800
33 x (7 x 26 x 0,40)
43,5
7120
1000
37 x (19 x 7 x 0,50) 61 x (7 x 11 x 0,51) 36 x (7 x 7 x 0,83) 61 x 19 x 1,03 127 x 3,20
49,2 50,0 48,0 45,3 41,6
9029 8966 8919 8896 8900
BRAIDED COPPER ROPES Round flexible copper ropes Standard: DIN 72 333 Part 3 Copper: DIN 17660, SRPS C.D6.400 Coating: tin EN 610, DIN 1704
MATERIAL Oxygen free copper purity of 99,95 %, with or without electrolytic coating. Tin purity of 99,95 %.
APPLICATION
It can use for heavy-duty. Braid is an element of reinforcement and prevents the "leakage" very flexible wire ropes and breaking of individual wires. In some cases, it can replace the braid. Rope is made with tin coating when necessary to protect rope from the influence of aggressive environment.
CONSTRUCTION DATA Cross section
Construction rope Construction braid
Diameter
Mass
± 0,2 [mm]
[kg/km]
2
N x n x d [mm]
N x n x d [mm]
10
7 x 28 x 0,20
24 x 5 x 0,20
4,2
90
16
7 x 45 x 0,20
24 x 5 x 0,20
5,2
145
25
7 x 74 x 0,20
24 x 5 x 0,20
7,3
225
35
12 x 68 x 0,20
24 x 14 x 0,20
7,8
315
50
19 x 56 x 0,20
24 x 20 x 0,20
9,5
450
70
27 x 58 x 0,20
36 x 18 x 0,20
11,0
630
95
27 x 82 x 0,20
36 x 24 x 0,20
13,2
855
120
37 x 80 x 0,20
36 x 24 x 0,20
15,0
1080
150
48 x 80 x 0,20
36 x 26 x 0,20
17,0
1350
[mm ]
201
CONDUCTORS FOR MEASURING TRANSFORMERS Profiled wrapped copper conductor partially flexible Standard: PSN
CONSTRUCTION Conductor: copper profiled conductor. Insulation: polyester tape. Outer covering: braid of cord.
APPLICATION
Conductor is transformers.
intended
for
winding
current
and
CONSTRUCTION DATA
202
Cross section
Cu number
Width x height
Mass
[mm2]
[kg/km]
[mm]
[kg/km]
17
164
6,8 x 3,0
152
28
269
8,1 x 4,0
250
42
404
15,0 x 3,0
374
56
538
15,0 x 4,0
500
84
807
15,0 x 7,0
750
111
1066
15,0 x 9,0
990
voltage
FLAT BRAIDS Stranded flat copper and tinned copper very flexible conductors Standard: DIN 72 333 Part 3
MATERIAL Oxygen free copper according to SRPS C.D6.400 purity 99,95 %. With or without electrolytic tin coating according to EN 610, DIN 1704 purity 99,95 %.
Hose are not rolled braid and hollow inside.
APPLICATION
Braids are intended for protective earthing of electrical networks, electrical appliances, electrical machinery and automobile industry.
CONSTRUCTION DATA Cross section
Construction
Width x height
Mass
[mm2]
N x n x d [kg/km]
[mm]
[kg/km]
6 10 12 14 16 21 25 35
50
70 95 120 150
12 24 32 36 36 36 32
x x x x x x x
28 23 21 22 12 24 15
x x x x x x x
0,15 0,15 0,15 0,15 0,20 0,15 0,20
36 x 31 x 0,15 36 x 18 x 0,20 36 x 38 36 x 21 36 x 54 34 x 3 x 19 36 x 30 24 x (6 x 19) 36 x (4 x19) 36 x 77 36 x 42 36 x (5 x 21) 36 x (2 x 30) 36 x (7 x 21) 36 x (4 x 20) 36 x 2 x 52 36 x 4 x 56 36 x 7 x 18
x x x x x x x x x x x x x x x x
0,15 0,20 0,15 0,15 0,20 0,15 0,15 0,15 0,20 0,15 0,20 0,15 0,20 0,20 0,15 0,20
7 x 1,2 11 x 1,5 12 x 1,7
56 98 111
18 x 1,5
135
20 x 1,6 (16 x 1,9)
152
22 x 2,0
200
22 x 2,5 (18 x 3,0)
240
25 x 3,0
330
33 x 3,2 (30 x 3,5)
470
35 x 4,5 (32 x 4,8)
650
38 x 4,8
900
47 x 5,5
1120
55 x 6,0
1440
203
BRASS WIRE Brass wire with high quality Standard: SRPS C.D1.120 Copper: DIN 17660, SRPS C.D2.100 Zinc: DIN 1706
MATERIAL Brass is: copper 63 % and zinc 37 %.
APPLICATION
Brass wire is used for sieves, and other products of general purposes.
CONSTRUCTION DATA
204
Diameter
Tolerance
Breaking strength
Elongation at break
Mass
[mm]
[mm]
[N/mm2]
[%]
[kg/km]
0,12
± 0,002
380 – 430
12
0,095
0,15
± 0,003
380 – 430
15
0,149
0,20
± 0,003
360 – 410
22
0,265
0,25
± 0,003
360 – 410
23
0,414
0,30
± 0,004
360 – 410
24
0,596
0,40
± 0,007
360 – 410
26
1,059
0,60
± 0,010
360 – 410
30
2,383
1,20
± 0,010
360 – 410
26
9,533
WIRE FOR EROSIMATE Brass wire with a small diameter tolerance and excellent electrical conductivity Standard: PSN 02 I 00 002 Copper: DIN 17660, SRPS C.D2.100 Zinc: DIN 1706
APPLICATION
MATERIAL
Brass is: copper 63 % and zinc 37 %. Brass wire is for erosimate that used as the electrode wire.
CONSTRUCTION DATA Diameter
Tolerance
Tensile strength
Elongation at break
Mass
[mm]
[mm]
[N/mm2]
[%]
[kg/km]
0,15 0,15 0,20 0,20 0,25 0,25 0,30 0,30
± ± ± ± ± ± ± ±
0,002 0,001 0,002 0,001 0,002 0,001 0,002 0,001
500 900 500 900 500 900 500 900
15 22 23 24 -
0,149 0,149 0,265 0,265 0,414 0,414 0,596 0,596
Galvanized brass wire Standard: PSN 02 G 021 Copper: DIN 17660, SRPS C.D2.100 Zinc: DIN 1706
MATERIAL Brass is: copper 63 % and zinc 37 %. Electrolytic coating is zinc.
APPLICATION
Wire is for cutting drills when requested high tensile strength wires as electrodes.
CONSTRUCTION DATA Diameter
Tolerance
Tensile strength
Elongation at break
Mass
[mm]
[mm]
[N/mm2]
[%]
[kg/km]
0,15 0,20 0,25 0,30
± ± ± ±
0,001 0,001 0,001 0,001
900 900 900 900
-
0,148 0,263 0,412 0,593
MCV Galvanized copper wire Standard: PSN 02 G 020 Copper: SRPS C.D6.400, SRPS C.D1.008 Covering: zinc DIN 1706
APPLICATION
MATERIAL Copper wire, zinc coating.
Wire use for erosimate where is used as electrode. MCV wire enable faster cutting up to 30%.
CONSTRUCTION DATA Diameter
Tolerance
Tensile strength
Elongation at break
Mass
[mm]
[mm]
[N/mm2]
[%]
[kg/km]
0,15 0,20 0,25 0,30
± ± ± ±
0,001 0,001 0,001 0,001
420 420 420 420
-
0,157 0,280 0,437 0,629
205
XHP 48/O-A; XHE 49/O-A Cable for overhead lines Standard: SRPS N.C5.230 Nominal voltage U0/U: 3.6/6kV; 6/10kV; 12/20kV; 20/35kV Test voltage: 9kV; 15kV; 30kV; 50kV
CONSTRUCTION Phase conductor Conductor: compacted multi-wire aluminium conductor class 2 according to SRPS N.C0.015. Inner semi-conductive layer: thermo stabile material. Insulation: XLPE compound. Outer semi-conductive layer: semi-conductive layer made from thermo stable material with sheath made from wrapped semi-conductive tape in case of XHP 48/O-A type of cable or made from semi-conductive swelling tape in case of XHE 49/O-A type of cable. Electrical protection: wrapped copper wire with contra-helical copper tape. Separator: polyester tape in case of XHP 48/O-A type of cable, and waterproof insulating swelling tape in case of XHE 49/O-A type of cable. Sheath: PVC compound for XHP 48/O-A type of cable; PE compound for XHE 49/O-A type of cable. Sheath colour: black. Supporting element Rope: Zinc-plated steel rope, 50 mm2 nominal cross-section, according to SRPS C.H1.061. Minimal tensile strength: 72,11kN, elasticity module: 17500daN/mm2. Rope diameter: 9mm. Rope is covered with black polyethylene layer. Diameter of the covering: 12 mm.
Cable is used instead of overhead lines in rural networks, in areas with intensive object and traffic constructions, when the problems of safety lengths arise from limited areas. The cable is laid on the pillars of the air network. It can be laid partially in earth where that is necessary.
APPLICATION
CONSTRUCTION DATA
206
3,6/6 kV n x q/q1+ qo 2
[mm ]
Al
Cu
[kg/km] [kg/km]
6/10 kV
12/20 kV
20/35 kV
Diameter
Mass
Diameter
Mass
Diameter
Mass
Diameter
Mass
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
[mm]
[kg/km]
3x1x25/10+50
216
360
41
1632
45
1846
-
-
-
-
3x1x 35/10+50
306
360
45
1800
50
2027
58
2660
-
-
3x1x 50/16+50
435
546
50
2207
54
2449
62
2961
78
4016
3x1x 70/16+50
609
546
52
2494
56
2750
65
3263
82
4469
3x1x 95/16+50
828
546
56
2841
60
3252
69
3715
86
4921
3x1x 120/16+50
1044
546
60
3127
65
3413
73
4016
88
5373
3x1x 150/25+50
1305
856
62
3715
67
4016
78
4770
93
5976
q – nominal cross section of the conductor, q1 – nominal cross section of the electrical protection, qo – nominal cross section of the supporting element Permissible temperature of the conductor: - operating temperature (constant load), max +90°C, - in short circuit (max 5 s), max +250°C, - short-term in emergency up to +130°C. Permissible environment temperature: - XHP 48/O-A, at laying, min -5°C; at laying, for bundles, min -40°C; - XHE 49/O-A, at laying, min -20°C; at laying, for bundles, min -50°C. Smallest bending radius: 15 D (D – diameter cable).
207
TECHNICAL DATA Proporties of materials 209 used for cables production
Nominal voltage
218
Halogen-free flame retardant materials Conductor resistance Core marking
210
CURRENT LOAD
219
213 215
Transport reels Laying of Cables
235 238
Properties of materials used for cables production Properties of metals Unit
Al
Cu
Fe
Sn
Pb
AlMgSi
Bronze BZ II
Specific electrical conductivity at 20oC
Sm/mm2
36
58
7,2-1,4
8,4
4,8
30,5
36
Specific electrical resistance at 20oC
Ωmm2/m
0,21
0,0328
0,02773
Property
Temperature resistance coefficient Density
0,028264 0,017241 0,14-0,72 0,119
10-3/K
4,0
3,9
4,5
4,4
4,2
3,6
3,8
3
2,7
8,9
7,8
7,3
11,34
2,7
8,9
g/cm
2
Tensile strength
N/mm
65-130
200-370
330-850
28
15
294
608-618
Thermal conductivity
W/Km
220
385
46
67
34
188
-
Coefficient of linear expansion
10-5/K
2,31
1,7
1,15
2,7
2,8
2,3
1,7
660
1083
1350
232
327
645
-
O
Melting point
C
The properties of some metals used for the manufacturing of certain construction cable elements: Aluminium (Al)
– conductor, armour (with single-core cables for electricity transmission via AC power), metal sheath
Copper (Cu)
– conductor, electrical protection
Steel (Fe)
– armour
Tin (Sn)
– metal sheath for copper wires within the conductor
Lead (Pb)
– metal sheat
Aldrey (AlMgSi)
– conductor
Properties of most commonly used insulating materials Property
Unit
EPR
FEP
PVC
PE
Si
XLPE
Working temperature of conductors, maximum
O
90
200
70
70
180
90
Temperature in short-circuit, maximum
O
250
200
160
150
350
250
Environment temperature
O
-30
-100
-30
-50
-60
-60
+135
+200
+70
+70
+180
+115
1015
1016
1013
1016
1012
1015
2,7
2,2
4-8
2,3
3,2
2,3
Specific volume resistance at 20 C, minimum
O
C C C
Ω cm
Dielectric constant at 20 OC
Properties of most common sheathing materials Property
Unit
CR
HDPE
LDPE
PVC
Si
Working temperature of conductors, maximum
O
90
90
90
70
180
Environment temperature
O
C
-40 +90
-60 +110
-60 +70
-30 +70
+180
Ω
109
-
-
-
109
6-9
2,3
2,3
4-8
3,2
Surface electrical resistance at 20 OC, minimum Dielectric constant at 20 OC
C
-60
209
Halogen-free flame retardant materials The statistics have recorded a significant number of fires caused by the adverse events on electrical installations. Studies have shown that the fire in buildings and rooms has often been transmitted via cables. This fact was of crucial significance for the measures taken to prevent the fire from spreading or, in case of spreading, to prevent it from spreading via cables, thus reducing the negative consequences for people, property or environment. The following table contains the literary data on toxic compounds and smoke density in the combustion products for certain materials used in cable industry:
University of Radnički, Novi Sad
Table: Comparative values of combustion products CO
NOX
SO2
HCN
HCl
Density of smoke Dm
PVC
1500