c a r e C o m m i t m e n t P e r f o r m a n c e

care Commitment Performance 2010 Acme Analytical Laboratories (Vancouver) Ltd. 1020 Cordova St. East, Vancouver, BC Canada V6A 4A3 Tel: (604) 253-3...
Author: Bennett Day
0 downloads 2 Views 1MB Size
care Commitment Performance

2010

Acme Analytical Laboratories (Vancouver) Ltd. 1020 Cordova St. East, Vancouver, BC Canada V6A 4A3 Tel: (604) 253-3158  Fax: (604) 253-1716 Toll Free in North America: 1-800-990-2263 E-mail: [email protected] Website: www.acmelab.com Please see back cover for addresses of Branch Labs.

senior staff NORTH AMERICA

Susie Woo Client Services Manager

Gustavo Canizales Acme Peru

Dean Toye, B.Sc. Co-Chairman – Board of Directors

Lisa Melton, David Kwok, Jean de Chavez Client Services Team

Oscar Olivares Acme Argentina

John Gravel, M.Sc., P.Geo. Co-Chairman and CEO

Steve Samotowka Acme Smithers and Acme Yellowknife

George Cartwright, B.Sc. President, COO Michael Toy, CGA Chief Financial Officer

ISO 9001:2008 FM 63007

Clarence Leong BC Certified Assayer, General Manager Rick McCaffrey, Dip. Chem. Business Development Terri-Lynn Ferguson, B.Sc. Quality System Manager Leonardo Arciaga BC Certified Assayer, Central-South American Projects Angelo Karitsiotis Global Sample Preparation Manager

Braulio Mendoza Acme Mexico

SOUTH AMERICA Geoff Woodfield VP Operations, South America Heriberto Muñoz Global Marketing and Sales Manager Luis Aucay Acme Ecuador Rory Forde Acme Guyana Rodrigo Perez Acme Brazil

Oscar Torres Acme Dominican Republic Eric Montiel Acme Chile Gustavo Canizales Acme Colombia

International George Siasios Acme Turkey

S

ince inception in 1971, Acme labs has been recognized as one of the leading geochemical and assaying laboratories to geologists and stock exchanges world wide.

3

Soil, Till & Sediment Index

Acme started as a family operated private business. For many years Acme remained a small but very successful business. Acme has always been known for innovation and quickly embracing new technology. This, along with a strong commitment to providing analytical methods tailored to exploration geochemistry assured Acme’s success.

5

Rock & Drill Core Index

Today Acme has grown into an employee owned business operating 19 offices in 11 countries. Our employee ownership reflects a very high level of personal commitment from our staff to our customers and our product. It is this care and commitment that makes Acme unique and strong. We have now incorporated this into our company slogan “Care, Commitment, Performance,” to convey how we approach our work, our company, and our customers. You will begin to see this slogan on all Acme Certificates, Invoices and emails.

25

Water Index

29

Vegetation Index

•  In Vancouver, we completed a new laboratory for sample preparation and fire assay. This laboratory is state of the art, and provides excellent work spaces for our staff, greatly improved efficiencies and triples our capacity for preparation and analysis;

32

Requesting Analysis

32

Packaging & Shipping Samples

33

Account Payment & Data Transfer

•  Our ICP/ICPMS laboratory has also been expanded so that it is one of the largest in the world, with additional capacity for test tube, large beaker, and fusion digestions;

34

Conversions & Supplies

35

Terms & Conditions

36

Computer Services

37

Requisition for Analysis Form

Over the past year Acme has completed some important milestones. •  In August, 2009 Acme acquired Global Discovery Labs (GDL). This laboratory has been providing excellent analytical services to Teck Resources as well as many other exploration and mining companies for over 30 years. This acquisition allows Acme to provide new services including XRay Fluorescence and XRay Diffraction (for Mineralogy) to our customers. More importantly however, this acquisition brings us a group of very experienced mineral analysis personnel.

•  In Chile, we have completed a large renovation and expansion to add analytical capacity and improved efficiency; •  Acme has added offices in Guyana, Colombia and Dominican Republic and expanded or improved many of our existing sample preparation offices; •  Acme has completed the installation of our new Laboratory Information Management System (LIMS). This is a powerful sample tracking and analytical reporting system that forms the core of all laboratory operations. This provides a high level of traceability for us and our customers; •  We have completed our new Acme Access web services for our customers to access their data at any time via the internet. This powerful tool gives our customers unprecedented access to information. All of these investments are made so we can serve you better. Care, Commitment, Performance. We will continue to exceed your expectations.

Soil, Till & Sediment

Sample Preparation, Storage & Disposal

Sample Preparation

Code

Description

SS80

Dry at 60°C, sieve (up to) 100g to –80 mesh, up to ½ kg   Sieve large samples: 80 mesh per ½ kg

S230

Dry at 60°C, sieve (up to) 100g to –230 mesh, up to ½ kg   Sieve large samples: 230 mesh, per ½ kg

Special Handling

Sample Storage & Disposal Fees

Cdn $2.25 +$1.00 $3.00 +$1.50

SSXX

Further sieving to other mesh sizes, per ½ kg

$1.50

SP100

Pulverize soils to –100 mesh ASTM in mild-steel pulverizer, per 100g

$3.00

SCP100

Pulverize soils to –100 mesh ASTM in ceramic pulverizer, per 100g

$7.85

RJSV

Saving all or part of reject fraction

$2.00

CLSP

Clay separation per 500g

ADRY

Air Dry sample (< 40°C), per 2 kg

HAND

Handling special projects, rejects and pulp retrieval, per hour

$50.00

MIN01

Heavy Mineral Separation, S.G. 2.96, per 200 g (setup charge $100)

$50.00

MIN02

Heavy Mineral Separation, S.G. 3.32, per 200 g (setup charge $100)

$50.00

RIFL

Split by riffle splitter material up to 5 kg

$2.10

WGHT

Weigh sample

$0.60

XWSH

Extra wash with glass between each sample in pulverizer

$1.25

SPLP

Sorting, labelling and boxing samples received as pulps

$0.30

RTRN

Return of all reject portions and/or pulps (British Columbia only)

DISP2

Heat treatment of soils and sediments, per sample

$0.45

STOR-PLP

Monthly storage of pulps after 90 days, per sample

$0.16

STOR3

Monthly storage of soil rejects, per sample

$0.35

No soil, till or sediment pulps or rejects (excluding those from BC Mainland, Yukon and NWT) can be returned and must be incinerated upon disposal. A disposal fee (DISP2) is charged for these samples. Soils will be discarded following analysis unless specific instructions are indicated on sample submittal forms. Soil rejects are discarded immediately after preparation. Note: Importation regulations may apply; contact lab prior to shipment. Note: Batch charge for sample submissions of less than 20 samples: $50.00

2 | Acme Labs Schedule of Services & Fees 2010

$10.00

$2.30

at cost

Soil, Till & Sediment

Soil, till and sediment have long been the interest of geochemists and geologists as a means of tracing mineralization to their sources. This could be sediment overlying bedrock which must be analysed and interpreted as to the underlying deposit or the means of tracing glacially dispersed elements or drainage systems back to their sources of mineralization. This interest has created an industry demand for new technology in laboratories, ever lower detection levels and a very stringent quality system to provide confidence in the results produced. The most important factors for assessing methods for geochem samples are precision and sensitivity. This is the ability of the method to detect subtle anomalies above baseline or background levels. At Acme Labs, we are at the forefront of this technology and innovation and we take pride in being the first choice for this type of survey by industry, academia and governments from all over the world.

Index 2

Sample Preparation, Storage & Disposal

6

Groups 1D & 1DX  – Geochemical: Aqua Regia Digestion

7

Group 1F-MS – Geochemical: Ultratrace Aqua Regia Digestion

8

Groups 1E & 1EX – Geochemical: 4-Acid Digestion

9

Group 1T-MS – Geochemical: Ultratrace 4-Acid Digestion

10

Group 1SL – Geochemical: Sequential Leaches

11

Group 2A – Geochemical: Single Element

12

Groups 2X & 5A – Geochemical: Single Element

13

Groups 3A, 3B & 3B-MS – Geochemical: Precious Metals

14

Groups 4A, 4B & 4X – Lithogeochemical: Whole Rock Major & Trace Element Analysis

16

Group 4 NILAT – Lithogeochemical: Whole Rock Major & Trace Element Analysis

17

Lithogeochemical: Optical & Mineralogical Studies

18

Group 6 – Assay: Precious Metals

19

Group 8X – Assay: Single Element

20

Group 7 – Assay: Multi Element

22

Groups 8AR & 8TD & 9 – Analysis in Santiago, Chile

Acme Labs Schedule of Services & Fees 2010  |  3

Rock & Drill Core

Sample Preparation, Storage & Disposal

Preparation

Code

Description

Cdn

R200–250

Crush 1 kg to 80% passing 10 mesh, split 250g and pulverize to 85% passing 200 mesh

$6.85

R200–500

Crush 1 kg to 80% passing 10 mesh, split 500g and pulverize to 85% passing 200 mesh

$7.85

R200–1000

Crush 1 kg to 80% passing 10 mesh, split 1000g and pulverize to 85% passing 200 mesh

$8.85

Extra crushing and saving rejects over 1 kg, per kg P200

Special Handling

Dry (60°C) and pulverize only to 85% passing 200 mesh, per 250g

+$1.55 $3.50

Extra pulverizing over 250g, per 250g

+$1.85

PSCB

Pulverizing by Ceramic Box, per 100g

$9.25

M150

Crush, pulverize, sieve 500g, save +150 and –150 mesh fractions for metallics analysis

$9.75

M200

Same as M150 but sieving to 200 mesh

$13.90

MXXX

Extra M150 or M200 pulverizing and screening, per 250g

+$3.50

HPUL

Hand pulverizing by mortar & pestle

$8.00

D105

Dry pulp samples at 105°C, per sample

$0.55

HAND

Handling special projects, rejects and pulp retrieval, per hour

MIXP

Mixing of received pulps

$0.60

MPCP

Compositing pulp, per 250g

$3.00

MPMP

Mixing & pulverizing composite, per 250g

$2.70

SPLT

Split large samples (>5 kg), per kg

$0.50

RIFL

Split by riffle splitter material up to 5 kg

$2.00

WGHT

Weigh sample

$0.60

XWSH

Extra wash with glass between each sample in pulverizer

$1.25

RPLP

Sorting, labelling and boxing samples received as pulp

$0.30

RS01

Rotary split up to 5 kg

$4.25

$50.00

Sample Storage & Disposal Fees

Code

Description

RTRN

Return of all reject portions and/or pulps

at cost

All rock rejects are stored for 3 months at no charge. Clients may purchase additional storage time.

DIS-RJT

Warehouse disposition of rejects

$0.25

DIS-PLP

Warehouse disposition of pulps

$0.10

STOR-RJT

Monthly storage of rejects after 90 days, per sample

$0.35

STOR-PLP

Monthly storage of pulps after 90 days, per sample

$0.16

Note: a minimum charge of $10/ quarter ($40 / yr) will apply to all clients with rejects in storage after 90 days.

Note: Concentrates and high NORM samples must be returned. Note: Batch charge for sample submissions of less than 20 samples: $50.00 4 | Acme Labs Schedule of Services & Fees 2010

Cdn

Rock & Drill Core

Rock and core samples are the final truth in any exploration program. Care and attention begin prior to any sample collection. Rock and core samples are dried then prepared by particle size reduction to produce a homogeneous sub-sample which is representative of the original sample. For most analytical methods, this sub-sample will undergo some form of dissolution and decomposition. Each sample decomposition procedure has its own advantages and limitations. The final technique used for the determination of elements is dependant on the required detection levels of the elements of interest. Acme Labs welcomes and encourages discussion with the geoscientist to determine the most appropriate analytical scheme of preparation, digestion and analysis to match the needs of their program. To this end, Acme Labs have developed mineraldeposit specific analytical packages for consideration.

Index 4

Sample Preparation, Storage & Disposal

6

Groups 1D & 1DX  – Geochemical: Aqua Regia Digestion

7

Group 1F-MS – Geochemical: Ultratrace Aqua Regia Digestion

8

Groups 1E & 1EX – Geochemical: 4-Acid Digestion

9

Group 1T-MS – Geochemical: Ultratrace 4-Acid Digestion

11

Group 2A – Geochemical: Single Element

12

Groups 2X & 5A – Geochemical: Single Element

13

Groups 3A, 3B & 3B-MS – Geochemical: Precious Metals

14

Groups 4A, 4B & 4X – Lithogeochemical: Whole Rock Major & Trace Element Analysis

16

Group 4 NILAT – Lithogeochemical: Whole Rock Major & Trace Element Analysis

17

Lithogeochemical: Optical & Mineralogical Studies

18

Group 6 – Assay: Precious Metals

19

Group 8X – Assay: Single Element

20

Group 7 – Assay: Multi Element

22

Groups 8AR, 8TD & 9 – Analysis in Santiago, Chile

24

Special Exploration Packages

Acme Labs Schedule of Services & Fees 2010  |  5

Soil, Till & Sediment

Rock & Drill Core

Geochemical Aqua Regia Digestion

Groups 1D, 1DX ICP-ES & ICP-MS

Group 1D Detection

You can choose economically priced ICP-ES (Group 1D) or ICP-MS (Group 1DX) analysis to complement your exploration program. Sample splits of 0.5g are leached in hot (95°C) Aqua Regia. Select a larger split size for more representative Au analysis. Refractory and graphitic samples can limit Au solubility. Sample minimum 1g pulp.

Group 1D01

Cdn

33 elements

$8.50

Group 1D02 Include Hg and Tl

Group 1D03



As



Au* B*†



2 ppm



0.5 ppb



100 ppm



20 ppm



20 ppm



2000 ppm

Ba*



1 ppm



1 ppm



10000 ppm

Bi



3 ppm



0.1 ppm



2000 ppm

Ca*



Cd



0.01 % 0.5 ppm



0.1 ppm



1 ppm



0.1 ppm



2000 ppm



1 ppm



1 ppm



10000 ppm



10000 ppm

Cu



Fe*



Ga*



5 ppm



Hg‡



1 ppm

K*



Mg*



Mn*



Mo



Na*



Ni



P*



1 ppm 0.01 %

0.01 % 1 ppm 0.01 % 2 ppm 1 ppm 0.01 % 1 ppm 0.001 %

40 %

1 ppm



1000 ppm



0.01 ppm



50 ppm



0.01 %



3 ppm



36 elements 15g

$18.25

Sc



5 ppm

36 elements 30g

$21.75



1 ppm

Th*



2 ppm

Ti*



Tl‡



Include U by request

Se

0.05 %



Te



0.001 % 5 ppm

0.1 ppm





Sr*

3 ppm



Sb

1DX3

40 % 2000 ppm

Co

$14.25

1DX2



Cr*



36 elements 0.5g

0.01 %





1DX1

10 % 10000 ppm



La*

Cdn

100 ppm



Pb

Group 1DX



0.5 ppm

S*

Code

0.1 ppm 0.01 %



+$1.00

+$0.50

0.3 ppm 0.01 %

Upper Limit

2 ppm

Cdn

Cdn

Include Uranium

Ag* Al*

Group 1DX Detection



0.01 %

1 ppm 0.01 % 1 ppm 0.1 ppm 0.001 % 0.1 ppm 0.001 % 0.1 ppm 0.05 %



10 %



10000 ppm



30 %



10000 ppm



2000 ppm



5 % 10000 ppm 5 % 10000 ppm



10 %

0.1 ppm



2000 ppm



0.1 ppm



100 ppm



0.5 ppm



100 ppm



1 ppm



10000 ppm



0.2 ppm



1000 ppm



0.1 ppm



2000 ppm



0.001 % 0.1 ppm



5 %



1000 ppm

V*



1 ppm



2 ppm



10000 ppm

W*



2 ppm



0.1 ppm



100 ppm

Zn



1 ppm



1 ppm



10000 ppm

*Solubility of some elements will be limited by mineral species present. †Detection limit = 1 ppm for 15g / 30g analysis.

6 | Acme Labs Schedule of Services & Fees 2010

Soil, Till & Sediment

Rock & Drill Core

Geochemical Ultratrace Aqua Regia Digestion

Group 1F-MS Ultratrace by ICP Mass Spec

Group 1F Detection

Larger splits (15 or 30g) give a more representative analysis of elements subject to nugget effect (e.g. Au). Au solubility can be limited in refractory and graphitic samples. Sample minimum 1g pulp. Acme Labs now offers analysis of Pb isotopes (Pb204, Pb206, Pb207, Pb208,) suitable for geochemical exploration of U and other commodities where gross differences in natural to radiogenic Pb ratios, is a benefit. Isotope values can be reported in both concentrations and intensities.

Code

Group 1F-MS

Cdn

1F01

Basic Suite (37 elements) 0.5g

$17.55

1F02

Basic Suite (37 elements) 15g

$21.55

1F03

Basic Suite (37 elements) 30g

$25.05

+1F08

Pd and Pt (add on)

$2.00

+1F09

REEs (add on)

$6.00

1F04

Full Suite (53 elements) 0.5g

$20.70

1F05

Full Suite (53 elements) 15g

$24.70

1F06

Full Suite (53 elements) 30g

$28.20

+1F07

Lead isotope (add on)

$12.00

*Some elements will report partial concentrations due to refractory minerals. †Detection limit = 1 ppm for 15g / 30g analysis.

Basic Suite

Full Suite

ICP Mass Spec analysis of a 0.5, 15 or 30g sample after Aqua Regia digestion for low to ultra-low determinations on soils, sediments and lean rocks.

Au* Ag* Al* As B*† Ba* Bi Ca* Cd Co Cr* Cu Fe* Ga* Hg K* La* Mg* Mn* Mo Na* Ni* P* Pb S* Sb Sc* Se Sr* Te Th* Ti* Tl U* V* W* Zn Be* Ce* Cs* Ge* Hf* In Li* Nb* Rb* Re Sn* Ta* Y* Zr* Pt* Pd*



0.2 ppb 2 ppb 0.01 % 0.1 ppm 20 ppm 0.5 ppm 0.02 ppm 0.01 % 0.01 ppm 0.1 ppm 0.5 ppm 0.01 ppm 0.01 % 0.1 ppm 5 ppb 0.01 % 0.5 ppm 0.01 % 1 ppm 0.01 ppm 0.001 % 0.1 ppm 0.001 % 0.01 ppm 0.02 % 0.02 ppm 0.1 ppm 0.1 ppm 0.5 ppm 0.02 ppm 0.1 ppm 0.001 % 0.02 ppm 0.05 ppm 2 ppm 0.05 ppm 0.1 ppm 0.1 ppm 0.1 ppm 0.02 ppm 0.1 ppm 0.02 ppm 0.02 ppm 0.1 ppm 0.02 ppm 0.1 ppm 1 ppb 0.1 ppm 0.05 ppm 0.01 ppm 0.1 ppm 2 ppb 10 ppb

Upper Limit

100 ppm 100 ppm 10 % 10000 ppm 2000 ppm 10000 ppm 2000 ppm 40 % 2000 ppm 2000 ppm 10000 ppm 10000 ppm 40 % 1000 ppm 50 ppm 10 % 10000 ppm 30 % 10000 ppm 2000 ppm 5 % 10000 ppm 5 % 10000 ppm 5 % 2000 ppm 100 ppm 100 ppm 10000 ppm 1000 ppm 2000 ppm 5 % 1000 ppm 2000 ppm 10000 ppm 100 ppm 10000 ppm 1000 ppm 2000 ppm 2000 ppm 100 ppm 1000 ppm 1000 ppm 2000 ppm 2000 ppm 2000 ppm 1000 ppb 100 ppm 2000 ppm 2000 ppm 2000 ppm 100 ppm 100 ppm

Acme Labs Schedule of Services & Fees 2010  |  7

Soil, Till & Sediment

Rock & Drill Core

Geochemical 4-Acid Digestion

Group 1E Detection

Groups 1E & 1EX ICP-ES & ICP-MS Combines a strong 4-acid digestion that dissolves most minerals with a choice of either ICP-ES or ICP-MS analysis and you get highly cost-effective near-total determinations with low to very low detection limits. A 0.25g split is heated in HNO3-HClO4-HF to fuming and taken to dryness. The residue is dissolved in HCl. Solutions are analysed by your choice of ICP-ES (Group 1E) or ICP-MS (Group 1EX).

Code

+G807

Ag



Al*



As‡



5 ppm



Au‡



4 ppm



+G807



200 ppm 10000 ppm

1 ppm



1000 ppm

Bi



5 ppm



0.1 ppm



4000 ppm

Ca





40 %

Cd



0.01 % 0.4 ppm



0.01 %



0.1 ppm



4000 ppm





1 ppm



2000 ppm

Co



2 ppm



0.2 ppm



4000 ppm

Cr‡



2 ppm



1 ppm



10000 ppm



10000 ppm

$12.00

Hg (add on)

+$10.50

K



La



Mg*



Mn*



2 ppm



0.01 %







0.01 %





2000 ppm



2000 ppm

0.01 % 5 ppm



Nb



2 ppm



Ni



2 ppm



Rb

Sb



10 %

0.1 ppm

+$10.50

S*



0.1 ppm





1000 ppm







0.01 %

60 %





Mo

P

0.1 ppm





Na

Pb

0.1 ppm 0.01 %

2 ppm

$17.00

2 ppm 0.01 %

0.002 % 5 ppm





0.01 % 1 ppm 0.1 ppm 0.001 %



30 %



10000 ppm



4000 ppm



10 %

0.1 ppm



2000 ppm

0.1 ppm



10000 ppm

0.001 % 0.1 ppm



5 %



10000 ppm





0.1 ppm



2000 ppm

0.1 %



0.1 %



10 % 4000 ppm



5 ppm



0.1 ppm



Sc



1 ppm



1 ppm



200 ppm

Sn*



2 ppm



0.1 ppm



2000 ppm

Sr



2 ppm



1 ppm



10000 ppm





0.1 ppm



2000 ppm



2 ppm



0.1 ppm



4000 ppm



Ta* Th

8 | Acme Labs Schedule of Services & Fees 2010

0.1 ppm

1 ppm

36 elements

‡Volatilization during fuming may result in some loss of As, Sb and Au.

10000 ppm



Hf*

*The digestion is only partial for some Cr and Ba minerals and some oxides of Al, Hf, Mn, Sn, Ta, Zr.







Hg (add on)

20 %

1 ppm

1 ppm



41 elements

200 ppm

1 ppm

Cu

Cdn





Fe*

Group 1EX

0.1 ppm 0.01 %



Li

Code



Ba*

Cdn

Group 1E

0.01 %

Upper Limit

Be*

Ce

Requires minimum 1g sample pulp.

0.5 ppm

Group 1EX Detection

Ti



U



0.01 % 20 ppm



0.001 % 0.1 ppm



10 %



4000 ppm 10000 ppm

V



2 ppm



4 ppm



W*



4 ppm



0.1 ppm



200 ppm

Y



2 ppm



0.1 ppm



2000 ppm

Zn



2 ppm



1 ppm



10000 ppm

Zr*



2 ppm



0.1 ppm



2000 ppm

Soil, Till & Sediment

Rock & Drill Core

Geochemical Ultratrace 4-Acid Digestion

Group 1T-MS Ultratrace by ICP-MS

Detection Limit 0.1 ppm



200 ppm

V



1 ppm



20 ppb



200 ppm

W*



0.1 ppm



Al*





20 %

Zn



0.2 ppm

10000 ppm

As‡



Be*

1 ppm

Detection limits may change without notice due to the nature of some samples. Massive sulphide samples will cause elevated detection limits.

Bi

Full Suite (43 + REEs) +G807

Hg (add on)

Cdn $22.70 +$10.50

Upper Limit

Ag

Requires minimum 1g sample pulp.

Group 1T–MS

Detection Limit

Au‡

ICP Mass Spec analysis of a 4-acid digestion on a 0.25g split giving total to near total values for all elements.

Code

Upper Limit

Ba*

0.02 % 0.2 ppm 1 ppm 0.04 ppm

10000 ppm

10000 ppm



200 ppm

1000 ppm

10000 ppm

Cs



0.1 ppm



2000 ppm



Hf*

0.02 ppm



1000 ppm

4000 ppm

Ca



0.02 %



40 %

Li



0.1 ppm



2000 ppm

Cd



0.02 ppm



4000 ppm

Nb



0.04 ppm



2000 ppm



4000 ppm

Rb



0.1 ppm



2000 ppm

Sn*

0.1 ppm



2000 ppm

Co



0.2 ppm

Cr



1 ppm

Cu



Fe*

10000 ppm

0.02 ppm

10000 ppm

Ta*



0.1 ppm



2000 ppm

0.02 %



60 %

Y



0.1 ppm



2000 ppm

Ga



0.02 ppm



100 ppm

Zr*



0.2 ppm



2000 ppm

K



0.02 %



10 %

La



0.1 ppm



2000 ppm

Mg*

0.02 %



30 %

Ce



0.02 ppm



2000 ppm

Pr



0.1 ppm



2000 ppm

Mn*

2 ppm

Mo



Na

0.002 %

0.05 ppm

Ni



P

0.001 %

0.1 ppm

10000 ppm

4000 ppm

Nd



0.1 ppm



2000 ppm



10 %

Sm



0.1 ppm



2000 ppm

10000 ppm

Eu



0.1 ppm



2000 ppm



Gd



0.1 ppm



2000 ppm

5 %

Pb



0.02 ppm

10000 ppm

Tb



0.1 ppm



2000 ppm

S



0.04 %



10 %

Dy



0.1 ppm



2000 ppm

Sb‡



0.02 ppm



4000 ppm

Ho



0.1 ppm



2000 ppm

Sc



0.1 ppm



200 ppm

Er



0.1 ppm



2000 ppm

Sr



1 ppm

Th



0.1 ppm

10000 ppm

Tm



0.1 ppm



2000 ppm



2000 ppm

Yb



0.1 ppm



2000 ppm

Lu



0.1 ppm



2000 ppm

Ti

0.001 %



10 %

U





4000 ppm

0.1 ppm

*The digestion is only partial for some Cr and Ba minerals and some oxides of Al, Fe, Hf, Mn, Sn, Ta, Zr. ‡Volatilization during fuming may result in some loss of As, Sb and Au.

Acme Labs Schedule of Services & Fees 2010  |  9

Soil, Till & Sediment

Geochemical Sequential Leaches

Group 1SL Sequential Leaches Selective or sequential extractions can target elements held by a specific soil phase or range of phases thus allowing better interpretation of geochemical processes. Used sequentially, the leaches can determine elements occurring in surface soils as salts or adsorbed ions on clays, organic compounds and amorphous Mn and Fe hydroxides. Used singularly, the stronger leaches are less selective. Contact our geochemist for further information. Sample minimum 2.5g pulp per leach.

Group 1SLW Al Ca Fe K Mn Mg Na P Ti Au Ag As Ba Be Bi Br Cd Ce Cl Co Cs Cu Dy Er Eu Ga Gd Ge Hf Hg Ho In



1000 5000 100 2000 50 100 3000 100 50 1 0.5 5 10 1 0.5 10 0.5 1 2000 1 0.5 5 0.1 0.1 0.1 0.5 0.1 0.1 0.1 1 0.05 0.05

Group 1SLE

1000 5000 5000 5000 50 1000 – 5000 1000 1 3 100 50 20 5 – 20 5 – 20 5 20 5 5 5 20 5 50 20 5 20 10

Group 1SLO

1000 5000 5000 5000 50 1000 – – 1000 1 3 100 50 20 5 – 20 5 – 20 5 20 5 5 5 50 5 50 20 5 20 10

10 | Acme Labs Schedule of Services & Fees 2010

Group 1SLW  A demineralized water leach for extracting the water-soluble component. Group 1SLE  1 M ammonium acetate leach for exchangeable cations adsorbed by clay and elements co-precipitated with carbonates. Group 1SLO  0.1 M sodium pyrophosphate leach for elements adsorbed by organic matter (humic and fulvic compounds). Group 1SLM  0.1 M hydroxylamine leach for elements adsorbed by amorphous Mn hydroxide, often the most reactive soil phase for scavenging mobile elements.

Group 1SLM

1000 5000 5000 5000 50 1000 – 5000 1000 1 3 100 50 20 5 – 20 5 – 20 5 20 5 5 5 20 5 50 20 5 20 10

Group 1SLF

1000 5000 5000 5000 50 1000 – 5000 1000 1 3 100 50 20 5 – 20 5 – 20 5 20 5 5 5 20 5 50 20 5 20 10

Group 1SLW La Li Lu Mo Nb Nd Ni Pb Pr Rb Re S Sb Sc Se Sm Sn Sr Ta Tb Te Th Tl Tm U V W Y Yb Zn Zr



2 0.1 0.05 1 0.5 1 5 3 0.5 2 0.05 10000 1 20 5 0.5 1 10 0.5 0.05 1 2 0.2 0.05 0.1 50 2 1 0.5 10 1

Group 1SLF  0.25 M hydroxylamine leach for elements adsorbed by amorphous Fe hydroxide and more crystalline Mn hydroxide.

Group 1SL Separate, per leach

$24.50

Sequential, per leach

$31.20

Set up charge, first leach

$330.00

Set up charge, additional

$220.00

Group 1SLE

Cdn

5 20 5 10 10 5 50 20 5 5 2 – 5 100 200 5 20 20 20 5 20 20 5 5 5 50 10 5 5 100 20

Note: All detection limits in ppb

Group 1SLO

5 20 5 10 10 5 50 20 5 5 2 – 5 100 200 5 20 20 20 5 20 20 5 5 5 50 10 5 5 100 20

Group 1SLM

5 20 5 10 10 5 50 20 5 5 2 – 5 100 200 5 20 20 20 5 20 20 5 5 5 50 10 5 5 100 20

Group 1SLF

5 20 5 10 10 5 50 20 5 5 2 – 5 100 200 5 20 20 20 5 20 20 5 5 5 50 10 5 5 100 20

Soil, Till & Sediment

Rock & Drill Core

Geochemical Single Elements

Group 2A Special Extraction Sample minimum 2g pulp

Code

Element

Method

2A01

B

Na2O2 Fusion / ICP



3 ppm

$10.00

2A04

F

Fusion, analysis by specific ion electrode

10 ppm

$10.00

2A05

LOI

Loss on Ignition @ 1000°C (or 500°C)



0.1 %

$8.35

2A06

pH

pH Electrode



0.1 unit

$8.35

2A07

Conductivity

Conductivity Electrode



2A67

Group 2A Leco Analysis Sample minimum 2g pulp

Detection

3 µS/cm

pH and Conductivity

Cdn

$8.35 $12.00

Code

Element

Method

Detection

2A08

Total C

Leco (total as C or CO2)



0.02 %

$12.10

2A09

Graphite C

Ignite 600°C, HCl leach, residue by Leco

0.02 %

$16.40

2A10

Organic C

Total C minus graphite C and carbonate

0.02 %

$27.30

2A11

Inorganic C

Direct CO2 evolution and Leco analysis



0.02 %

$12.10

2A12

C&S

Both by Leco



0.02 %

$13.40

2A13

Total S

Total S by Leco



0.02 %

$12.10

Surcharge on S > 20%, add

Cdn

$5.75

2A14

Sulphate

Leco after ignition at 800°C



0.05 %

$16.40

2A15

Sulphide

Total S minus Sulphate S



0.05 %

$17.85

2A16

HCl/S

HCl extractable Sulphur



0.02 %

$16.40

2A17

HNO3 /S

HNO3 extractable Sulphur



0.02 %

$16.40

Acme Labs Schedule of Services & Fees 2010  |  11

Soil, Till & Sediment

Rock & Drill Core

Geochemical Single Elements

Group 2X XRF Minor Element Analyses

Element As

Pressed pellet



Det. Limit

Element

3 ppm

Ni

Det. Limit

3 ppm

Ba



2 ppm

Pb



3 ppm

Bi



3 ppm

Rb



2 ppm

Ce



3 ppm

Sb



3 ppm

Co



3 ppm

Se



2 ppm

Cr



10 ppm

Sm



2 ppm

Cu



3 ppm

Sn



2 ppm

Group 2X

Cdn

First Element

$8.00

Cs



3 ppm

Sr



2 ppm

$2.00

Fe



3 ppm

Ta



2 ppm

Each Additional Element

Group 5A Neutron Activation

Gd



3 ppm

Th



2 ppm

Ge



3 ppm

U



2 ppm 2 ppm

Hf



3 ppm

V



K2O



3 ppm

W



3 ppm

La



2 ppm

Y



2 ppm

Nb



2 ppm

Yb



2 ppm

Nd



2 ppm

Zn



2 ppm

Zr



2 ppm

Mn



Mo



2 ppm

Det. Limit

Element



2 ppb

Na

Element Au

Analysis by affiliate laboratory. Total determination of Au plus 34 elements by gamma ray analysis after nuclear irradiation. Requires 5 – 30g pulp.

Group 5A

Cdn

Full Suite

$20.00

12 | Acme Labs Schedule of Services & Fees 2010

0.01 %

Ag



5 ppm

As



0.5 ppm

Det. Limit

0.01 %

Nd



5 ppm

Ni



100 ppm

Ba



50 ppm

Rb



15 ppm

Br



0.5 ppm

Sb



0.1 ppm 0.1 ppm

Ca



1 %

Sc



Ce



3 ppm

Se



3 ppm

Co



1 ppm

Sm



0.1 ppm

Cr



5 ppm

Sn



0.01 %

Cs



1 ppm

Sr



0.05 %

Eu



Fe



0.2 ppm 0.01 %

Ta



0.5 ppm

Th



0.2 ppm

Hf



1 ppm

Tb



0.5 ppm

Hg



1 ppm

U



0.5 ppm

Ir



5 ppb

W



1 ppm

La



0.5 ppm

Yb



0.2 ppm

Lu



0.05 ppm

Zn



50 ppm

Mo



1 ppm

Soil, Till & Sediment

Rock & Drill Core

Geochemical Precious Metals

Group 3A Au by Wet Digestion Recommended for soils, sediments, vegetation or reconnaissance rock samples. Samples are digested in Aqua Regia then analysed by ICP-Mass Spec.

Code

Element

Detection Limits

Upper Limits

Method

Cdn

3A01

Au

0.5 ppb

10 ppm

15g / Aqua Regia digestion / ICP–MS

$9.50

+3A02

30g sample (add on)

+$3.50

Ignition for rocks*

+$1.15

*Refractory, massive sulphide and graphitic samples can limit Au solubility. Rock samples are ignited at 550˚C before Aqua Regia leaching.

Group 3B & 3B-MS Au & PGMs by Fire Geochem A lead-collection fire-assay fusion for total sample decomposition, digestion of the Ag dore bead and ICP-ES (Group 3B) or ICP-MS (Group 3B-MS) analysis. Group 6 precious metals assay recommended for Au or PGMs over 1000 ppb.

Code

Package

Element

Detection Limits

Upper Limits

Method

3B01

Group 3B

Au



2 ppb

10 ppm

30g / Ag inquart fire assay fusion / ICP–ES

$13.75

Au Pt Pd



2 ppb 3 ppb 2 ppb

10 ppm 10 ppm 10 ppm

30g / Ag inquart fire assay fusion / ICP–ES or ICP–MS

$16.00

Au Pt Pd

1 ppb 0.1 ppb 0.5 ppb

10 ppm 10 ppm 10 ppm

30g / Ag inquart fire assay fusion / ICP–MS

$19.00

50g sample (add on)

+$2.85

3B02

3B03

Group 3B-MS

+3B04

Cdn

Note: Sulphide-rich samples require a 15g or smaller sample for proper fusion.

Acme Labs Schedule of Services & Fees 2010  |  13

Soil, Till & Sediment

Rock & Drill Core

Lithogeochemical Whole Rock Major & Trace Element Analysis

Group 4A Whole Rock by ICP

Group 4B Total Trace Elements by ICP-MS

A cost-effective rock characterization package comprising four separate analytical tests.

This is the perfect addition to Group 4A. This package comprises two separate analyses. Rare earth and refractory elements are determined by ICP mass spectrometry following a Lithium metaborate / tetraborate fusion and nitric acid digestion of a 0.2g sample (same decomposition as Group 4A). In addition a separate 0.5g split is digested in Aqua Regia and analysed by ICP Mass Spectrometry to report the precious and base metals (in highlight). This is the same method as Group 1DX.

Total abundances of the major oxides and several minor elements are reported on a 0.2g sample analysed by ICP-emission spectrometry following a Lithium metaborate/ tetraborate fusion and dilute nitric digestion. Loss on ignition (LOI) is by weight difference after ignition at 1000°C. Unique to our lab is the addition of total carbon and sulphur analysis by Leco.

Code

Group 4A

Cdn

4A01

Any 1 element

$14.60

4A02

Full Suite (21 parameters)

$27.25

4A03

Extended Package* (Full Suite + Ce Co Cu Zn)

$30.40

4A04

Major Oxides & LOI (no C or S)

$23.25

Group 4X Whole Rock by XRF LiBO2 fusion followed by XRF analysis for major oxides and LOI. X-ray fluorescence is a physical method that does not suffer from difficulties such as small sample size, incomplete dissolution, matrix effects and sample inhomogeneity found in “wet” methods. Requires a 12g sample pulp.

Code

Group 4X

Cdn

4X01

Full Suite

$31.50

4X02

Major oxides + LOI (no C or S)

$27.50

14 | Acme Labs Schedule of Services & Fees 2010

Prices are for routine geological samples. Acme may refuse to analyse or charge extra for non-geological materials. Group 4A and 4B each require 5g for analysis, 10g for combined package (Group 4A-4B).

Code

Group 4B

Cdn

4B01

Any 1 element

$17.00

4B02

Full Suite (45 elements)

$36.40

4B03

Refractory and REEs only

$26.70

4A4B

(4A02 + 4B02)

$53.30

4X4B

(4X01 + 4B02)

$54.60

Group 4A Det. Limit

Group 4X Det. Limit

Upper Limit

Group 4A Det. Limit

Group 4B Det. Limit

Upper Limit

SiO2



0.01 %



0.1 %



100 %

Au





0.5 ppb



100 ppm

Al2O3



0.01 %



0.01 %



100 %

Ag





0.1 ppm



100 ppm

Fe2O3



0.04 %



0.01 %



100 %

As

CaO



0.01 %



0.01 %



100 %

Ba



5 ppm



1 ppm



10000 ppm



1 ppm



50000 ppm 10000 ppm

MgO



0.01 %



0.01 %



100 %

Be





1 ppm



Na2O



0.01 %



0.01 %



100 %

Bi





0.1 ppm



2000 ppm

K 2O



0.01 %



0.01 %



100 %

Cd





0.1 ppm



2000 ppm

MnO



0.01 %



0.01 %



100 %

Co

TiO2



0.01 %



0.01 %



100 %

Cs

P2O5



0.01 %



0.01 %



100 %

Cu

Cr2O3



0.002 %



100 %

Ga

5 ppm





20 ppm* –



5 ppm* –



0.2 ppm



10000 ppm



0.1 ppm



10000 ppm



0.1 ppm



10000 ppm



0.5 ppm



10000 ppm 10000 ppm

Ba





0.01 %



100 %

Hf





0.1 ppm



LOI



0.1 %



0.1 %



100 %

Hg





0.1 ppm



100 ppm

C



0.01 %



0.01 %



100 %

Mo





0.1 ppm



2000 ppm

S



0.02 %



0.02 %



100 %

Nb



5 ppm



0.1 ppm



50000 ppm

Ni



20 ppm



0.1 ppm



10000 ppm

Pb





0.1 ppm



10000 ppm

Rb





0.1 ppm



10000 ppm





0.1 ppm



2000 ppm





10000 ppm

Sb Sc



1 ppm

Se





0.5 ppm



100 ppm

Sn





1 ppm



10000 ppm

Sr



Ta

2 ppm –



0.5 ppm



50000 ppm



0.1 ppm



50000 ppm 10000 ppm

Th





0.2 ppm



Tl





0.1 ppm



1000 ppm

U





0.1 ppm



10000 ppm

V





8 ppm



10000 ppm

W





0.5 ppm



10000 ppm

Y



3 ppm



0.1 ppm



50000 ppm

Zn



5 ppm*



1 ppm



10000 ppm

Zr



5 ppm

La Ce Pr



30 ppm* –



0.1 ppm



50000 ppm



0.1 ppm



50000 ppm



0.1 ppm



50000 ppm



0.02 ppm



10000 ppm

Nd





0.3 ppm



10000 ppm

Sm





0.05 ppm



10000 ppm

Eu





0.02 ppm



10000 ppm

Gd





0.05 ppm



10000 ppm

Tb





0.01 ppm



10000 ppm

Dy





0.05 ppm



10000 ppm

Ho





0.02 ppm



10000 ppm

Er





0.03 ppm



10000 ppm

Tm





0.01 ppm



10000 ppm

Yb





0.05 ppm



10000 ppm

Lu





0.01 ppm



10000 ppm

Note: Highlighted elements by Aqua Regia/ ICP-MS analysis in 4B package.

Acme Labs Schedule of Services & Fees 2010  |  15

Soil, Till & Sediment

Rock & Drill Core

Lithogeochemical Whole Rock Major & Trace Element Analysis

Group 4 NILAT For Nickel-Laterite

Full Suite Elements SiO2



0.01 %

Exploration and evaluation of nickel laterite requires total determination and mass balance accounting of the major rock-forming elements and the commodity elements Ni, Cu and Co. Acme delivers these requirements with Group 4A-7TD that combines a cost effective whole-rock determination and a totaldigestion, multi-element assay.

Al2O3



0.01 %

Fe2O3



0.04 %

CaO



0.01 %

MgO



0.01 %

Na2O



0.01 %

K2O



0.01 %

MnO



0.01 %

The package contains four separate analytical tests that report 23 parameters (11 major oxides, 10 minor and trace elements, loss on ignition and SUM). SUM is the sum total of these constituents that gives a mass balance close to 100% when all the major constituents are accurately determined and accounted for. The redundancy of two separate Ni determinations (Group 4A and Group 7TD) provides an additional check on accuracy.

TiO2



0.01 %

P2O5



0.01 %

Cr2O3



0.002 %

LOI



0.01 %

SUM



0.01 %

Ba



Co



0.001 %

Cu



0.001 %

Nb



5 ppm

Ni



20 ppm

Ni



Sc



1 ppm

Sr



2 ppm

Y



3 ppm

Zr



5 ppm

Samples must be dried (prep method D105) prior to analysis.

Group 4 NILAT

Cdn

Full Suite 23 elements

$30.00

C+S option

+$6.00

Detection Limit

Optional Elements

16 | Acme Labs Schedule of Services & Fees 2010

5 ppm

0.001 %

Detection Limit

C



0.02 %

S



0.02 %

Soil, Till & Sediment

Rock & Drill Core

Lithogeochemical Optical & Mineralogical Studies

Sample Preparation for Optical Studies

Cdn Thin sections: standard 27 x 46mm with/ without coverslip Other sizes upon request Impregnation (where required), sample dependent

$5.00

Casting (mill concentrates, drill chips, etc.)

$10.00

Polished sections

$40.00

Polished thin sections

$55.00

K-feldspar staining (thin sections or off-cuts)

$3.50

Slabbing, lapping, display polishing

Specialized Mineralogical Studies



Results are provided in report form, illustrated with photographs where appropriate.

Reflected and transmitted light microscopy

Estimates available upon request.

$20.00

hourly charge

Cdn

Mineral identification by XRD – diffraction pattern/interpretation

$80.00

Photomicrography Scanning electron microscopy / energy dispersive x-ray analysis

hourly charge

Alteration mineral studies Examination of alluvial concentrates Studies of metallurgical test products

Acme Labs Schedule of Services & Fees 2010  |  17

Soil, Till & Sediment

Rock & Drill Core

Assay Precious Metals

Group 6 Fire Assay

Code

Element

G601

Au

Detection

Upper Limit

Method

Cdn

Fire Assay 30g – Instrumentation Finish (Automatic Grav Overlimits)

$15.25

Metallics Fire Assay**

$26.00

Au by Fire Assay 30g – Instrumentation Ag by 7AR

$19.00

G604

Metallics Fire Assay**

$30.90

G605

Include all Group 7AR elements

+$7.75

Fire Assay on 30g sample

$18.50

Metallics Fire Assay**

$30.30

Fire Assay on 30g sample*

$23.00

G602 G603

G606

0.005 g/t

Au, Ag*

Au, Pt, Pd

0.17 g/t

(Ag) 2 g/t



10 ppm

0.01 g/t

(Au) 10 ppm (Ag) 300 ppm

10 ppm

G607



G608

Au, Ag,* Pt, Pd

G609



Metallics Fire Assay**

$34.65

0.01 g/t

10 ppm

G613

Ag



Fire Assay on 30g sample Gravimetric

$18.50

G614

Ag



Fire Assay on 50g sample Gravimetric

$21.00

+G610

50g sample

+$2.50

+G611

Include all Group 7AR elements

+$7.75

+G612

Gravimetric Finish (add on)

+$3.25

Add On Options

*Ag by Group 7AR detection limit 2g/t to 300g/t **All metallic fire assay requires preparation by M150 or M200

18 | Acme Labs Schedule of Services & Fees 2010

Soil, Till & Sediment

Rock & Drill Core

Assay Single Element

Group 8X XRF

Element

Specific elements on a fusion.

LLD Detection Limit

Ba



0.01 %

Ce



0.01 %

Co



0.01 %

Cs



0.01 %



0.01 %

Group 8X

Cdn

Cu Hf



0.01 %

First Element

$15.00

Mo



0.01 %

Nb



0.01 %

Nd



0.01 %

Ni



0.01 %

Pb



0.01 %

Rb



0.01 %

Sm



0.01 %

Sn



0.01 %

Sr



0.01 %

Ta



0.01 %

Th



0.01 %

Ti



0.01 %

U



0.01 %

W



0.01 %

Y



0.01 %

Zn



0.01 %

Zr



0.01 %

Each Additional Element

$4.50

Note: Surcharges may apply for high Sulphur

Group 8 Single Element Assays The following methods require a minimum of 1g of sample pulp except for preciousmetal assays that require a minimum of 30g.

Code

Element

G801

Copper – Non-Sulphide

Cdn CuO

$15.75

G802

Molyoxide Leach

MoO

$15.75

G803

Fluorine

F

$16.40

G804

Gallium

Ga

$16.40

G805

Germanium

Ge

$13.00

G806

Iron – Ferrous

FeO

$20.65

G807

Mercury

Hg

G808 G809

$10.50

Moisture (110°C)

H2 O



$6.25

Lattice Water (1500°C)*

H2 O +

$24.90

G810

Nickel sulphide

Ni

$24.90

G812

Specific Gravity Pulp

SG

$12.00

G813

Specific Gravity Core

SG

G814

Ba by Na2CO3 / K 2CO3 fusion

$12.00 $25.00

*includes correction for FeO

Acme Labs Schedule of Services & Fees 2010  |  19

Soil, Till & Sediment

Rock & Drill Core

Assay Multi-Element

Group 7 ICP & ICP-MS

Code

Group 7AR

7AR1

Any element

$10.10

7AR2

Full Suite

$14.00

7AX1

Group 7AX

$19.10

Groups 7AR, 7TD and 7PF report %-level concentrations as determined by ICP emission spectrometry.

Code

Group 7TD

Cdn

7TD1

Any element

$12.00

Two new packages (Groups 7AX and 7TX) combine both ICP emission spectrometry and ICP mass spectrometry analysis to extend the lower detection limits and provide a broader spectrum of elements.

7TD2

Full Suite

$16.00

7TX1

Group 7TX

$23.10

Code

Group 7PF

Cdn

7PF1

Any element

$13.50

7PF2

Full Suite

$17.50

Code

Group 7KP

7KP1

Any element

$12.50

7KP2

Full suite

$16.00

The following multi-element assays provide optimum precision and accuracy for highgrade rock and drill core samples with a selection of digestion methods to best suit the ore type.

Group 7KP will provide total values for select elements. Sample minimum 1g pulp.

20 | Acme Labs Schedule of Services & Fees 2010

Cdn

Cdn

Group 7AR Hot Aqua Regia digestion for base-metal sulphide and precious-metal ores. ICP-ES analysis. Group 7AX Same digestion as 7AR above but includes ICP-ES and ICP-MS analysis.

G7AR Det. Lim. Ag



Al



0.01 %



As



0.01 %





Ba



Be



Group 7PF Sodium peroxide fusion for refractorymineral ores. Group 7KP Phosphoric acid digestion for select elements.



0.01 %



G7TD Det. Lim.

0.5 ppm 0.01 %

G7TX Det. Lim.

2 g/t



0.01 %



5 ppm

0.02 %



5 ppm

– –









5 ppm









5 ppm







0.5 ppm





0.01 %

0.01 %



0.01 %





0.01 %



0.001 %



0.5 ppm

0.001 %





0.001 %



0.5 ppm





– –

5 ppm 0.5 ppm







0.5 ppm 0.01 %

G7KP Det. Lim.



Ca Ce

G7PF Det. Lim.



Cd Co

Group 7TX Same digestion as 7TD above but includes ICP-ES and ICP-MS analysis.

2 g/t

B

Bi

Group 7TD Hot 4-Acid digestion for sulphide and silicate ores. ICP-ES analysis.

G7AX Det. Lim.

0.01 % 0.5 ppm

0.01 %

– –













5 ppm





0.001 %



1 ppm





Cr



0.001 %



0.5 ppm

0.001 %



1 ppm

0.01 %



Cu



0.001 %



0.5 ppm

0.001 %



0.5 ppm

0.01 %



Fe



0.01 %



0.01 %



0.01 %



Ga



Hf



Hg



0.001 %

K



0.01 %

La



Li



Mg



0.01 %



0.01 %









0.05 ppm



0.01 %





5 ppm





0.01 %



0.01 %







0.5 ppm

0.01 % 0.5 ppm –













0.5 ppm









0.5 ppm











0.01 %

0.01 %

Mn



0.01 %



5 ppm

0.01 %



5 ppm



Mo



0.001 %



0.5 ppm

0.001 %



0.5 ppm



Na



0.01 %



Nb







Ni



0.001 %



P



0.001 %



Pb



0.01 %



Rb

0.01 %



0.05 %



Sb



0.001 %



0.01 %



0.5 ppm

0.02 %



0.05 %



– – –

Sn







5 ppm –



5 ppm





0.5 ppm





0.5 ppm





0.01 %

– –



Ti





Tl





0.5 ppm



U





0.5 ppm



0.001 %





10 ppm



0.001 %



0.5 ppm



0.01 %

– 5 ppm

– 0.5 ppm

Th

0.5 ppm

0.05 %



Ta



















2 ppm

Zr



0.5 ppm







0.5 ppm









1 ppm

Se

Zn





0.5 ppm



Y

0.01 %



0.5 ppm

W

0.5 ppm





0.5 ppm



V

0.001 %

0.01 %





0.01 %





0.001 %





0.5 ppm 0.01 %

0.001 %

0.05 %

0.001 %



0.01 %





Sc

Sr







S

0.01 % –

0.5 ppm 0.001 %





– 0.01 %





– 0.01 % – 0.01 % –



0.01 %



0.001 % –

0.001 %









0.5 ppm



10 ppm 0.5 ppm



0.5 ppm





– –



0.01 %

5 ppm 0.5 ppm





0.001 %



0.005 %

– 0.01 %



– 0.01 % –

– – –

Note: Highlights in table indicate partial digestion if refractory minerals are present.

Acme Labs Schedule of Services & Fees 2010  |  21

Soil, Till & Sediment

Rock & Drill Core

Analysis at Acme Labs Santiago, Chile

Method

Group 8AR

Aqua regia digestion ore grade / AAS

Group 8TD

4 Acid digestion ore grade / AAS

22 | Acme Labs Schedule of Services & Fees 2010

Element

Detection

Ag



Cu

0.001-30 %

Mo

0.001-10 %

Fe

0.001-30 %

Zn

0.01-30 %

Pb

0.01-10 %

As

0.01-10 %

Ag



Cu

0.001-30 %

Mo

0.001-10 %

Fe

0.001-30 %

Zn

0.01-30 %

Pb

0.01-10 %

As

0.01-10 %

Cdn$ First Element

Cdn$ Additional Element

1-1000 ppm

$10.50

$3.50

$11.75

$3.50

1-1000 ppm

Group 9

Cdn$ Additional Element

Method

Element

G901

CuS Citric Acid 1M / AAS

CuS

0.001-10 %

$11.75

-

G902

CuS Sulfuric Acid 5% / AAS

CuSH

0.001-10 %

$11.75

-

G903

CuS NaCN / AAS

CuCN

0.01-10 %

$11.75

-

G904

Sequential Copper (CuSH, CuCN, CuR)

CuSeq



$31.75

-

Au



0.1 ppb

Ag



0.1 ppb

Cu



0.01 ppm

$23.50

$2.35

Zn



0.01 ppm

Au



0.01 ppm

$41.15

-

Au



0.01 ppm

Cu



0.01 ppm

$17.65

$5.85

G905

BLEG, Cyanide leach for 12 hours Organic extraction / AAS

G906

Bottle Roll Test, Cyanide leach on 500g pulp / AAS

G907

Bottle Roll Test, Cyanide leach on 20g pulp / AAS

Detection

Cdn$ First Element

Code

Acme Labs Schedule of Services & Fees 2010  |  23

Rock & Drill Core

Special Exploration Packages

Code

Description

Geo1

Group 1D + Group 3A (with ignition for rock samples)

$17.25

Geo2

Group 1DX (Aqua Regia/ICP-MS 0.5g) + Group 3B (fire geochem Au)

$24.75

Geo3

Group 4A (Whole Rock Majors) + Group 4B (Trace Elements)

$53.30

Geo4

Group 1D (30 element AR/ICP) + Group 3B (fire geochem Au, Pt, Pd)

$23.00

Geo5

Group 1T + 7 (Au, As, Hg, Sb, Se, Te and Tl by 0.5g Aqua Regia/ICP-MS)

$33.90

Geo6

Group 1EX (41 element 4-acid/ICP) + Group 3A (Au wet geochem)

$23.85

Assay2

Group 7AR (multi-element assay by ICP) + Group 6 (Au & Ag Fire Assay)

$26.75

Assay3

Group 1DX (Aqua Regia /ICP-MS 0.5g) + Group 6 (Au Fire Assay on 30g)

$26.10

24 | Acme Labs Schedule of Services & Fees 2010

Cdn

Water

The mobility of water makes it an excellent exploration tool. As water contacts an ore deposit, major changes occur in its chemical composition. This can occur as rain causing weathering on rocks or flowing underground water. These water soluble weathering products and suspended matter can then be compared to background levels of chemical elements in the water to aid in determining the dispersion pattern. The sensitivity of the ICP-Mass Spectrometers at Acme Labs provides the ultra low detection limits required to determine background and anomalous levels. Note: Batch charge for sample submissions of less than 20 samples: CDN$50.00.

Index 26

Sample Preparation & Preservation

27

Group 2B – Geochemical: Water Analysis

27

Group 2B – Geochemical: Anion Analysis

28

Groups 2C & 2D – Geochemical: Water Analysis

Acme Labs Schedule of Services & Fees 2010  |  25

Water

Sample Preparation & Preservation

Samples received by Acme Labs are run as received. In order to ensure the most accurate readings of samples submitted it is recommended that the following handling procedures be considered when planning your sampling and choosing a method of delivery for samples. Sampling

In order to ensure a representative sample, samples should be collected in pre-cleaned, HDPE plastic bottles that have been rinsed with sample three times prior to use. Keep in mind that if dissolved metals are required the sample should be filtered through a 0.45 filter prior to acidification Preservation

If anions, pH alkalinity or conductivity are required samples should be kept refrigerated. For metals analysis due to the problems of absorption or precipitation the sample should be acidified to pH

Suggest Documents