PDU 1 Device address (Node ID):
PDU1
Direct Priori ion ty Receive
Type
7
R
0
DP
0
PF
239
Parameter
10 PS
10
SA
0
29Bit ID (dez)
PGN
61194
485427712
29Bit ID (hex)
1CEF0A00
DLC Byte 0 Byte 1 Byte 2
8
PDU1
Receive
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receiv e
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
239
10
0
61194
485427712
1CEF0A00
8
4
PDU1
Receive
Byte 0 Byte 1 Byte 2
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receiv e
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receiv e
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receiv e
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receive
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
PDU1
Receiv e
7
0
0
239
10
0
61194
485427712
1CEF0A00
8
Byte 4
Byte 3
Byte 4
Byte 5
Byte 5
Amount of measurements used for arithmetic mean of Alarm conzentrationen
Byte 3
Byte 4 ordinal numeral (ISO/SAE) for alarm at 4 µm
Byte 3
Byte 4
250
Byte 7
Byte 6
Byte 7
Byte 5 ordinal numeral (ISO/SAE) for alarm at 6 µm Byte 5
Byte 6 Alarm Type: 0 = Standard Mode 1 = Filter Mode
Byte 7 Display & Alarm Standard Displayed Standard and Alarm Trigger Bit Setting 0 = ISO 1 = SAE 2 = NAS 3 = GOST
Byte 6 ordinal numeral (ISO/SAE) for alarm at 14 µm
Byte 7 ordinal numeral (ISO/SAE) for alarm at 21 µm
Byte 6
Byte 7 ordinal numeral NAS for alarm
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 ordinal numeral GOST for alarm
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 Alarm threshold temperature, range: 0..85 °C 0 = deactivated
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 enable communication interface: 0: RS232 1: CANopen 2: auto 3: J1939
Byte 3
Byte 4
Byte 5
Byte 6
If auto is activated and CAN is detected, prefered protokoll type is defined via RS232 command: SCAutoDef 0 = CANopen 1 = J1939
Byte 7 CAN-Baudrate: 3: 125k 4: 250k 5: 500k 6: 1000k
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 RS232-Baudrate: 0: 9600 1: 19200 2: 57600 3: 115200
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 CAN Node-ID
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7 CAN Terminator 0 = off 1 = on
Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Flow in deciliter/minute: if 0 is set, then device cacluates the flow automaticl, range between. 50 and 500 flow is fixed Byte 3
Byte 4
Byte 5
Byte 6
Byte 7
Amount of particles to be detected in automatic mode
Byte 3
Byte 4
Byte 3
Byte 4
17
Byte 0 Byte 1 Byte 2
J1939 AH OpCom II - 2.00.14 2015.02.06_save
Byte 3
16
Byte 0 Byte 1 Byte 2
Byte 7 Measurement mode 0 = Time Control 1 = Digital I/O-Pin 2 = Button/RS232/CANopen/J1939 Controll 3 = Automatic
Measurement time in seconds Delay time between two measurements in seconds (Range: 0x1..0x1517F, corresponds to 1(Range: 0x1E..0x12C, corresponds to 86399 seconds) 30-300 seconds)
15
Byte 0 Byte 1 Byte 2
Notes
History disable 0 = History enabled 1 = History disabled
14
Byte 0 Byte 1 Byte 2 0
Byte 6
13
Byte 0 Byte 1 Byte 2
7
Byte 5
12
Byte 0 Byte 1 Byte 2 7
Byte 4
11
Byte 0 Byte 1 Byte 2 0
Byte 3
10
Byte 0 Byte 1 Byte 2
7
Byte 6
9
Byte 0 Byte 1 Byte 2
7
Byte 5
8
Byte 0 Byte 1 Byte 2 0
Byte 4
7
Byte 0 Byte 1 Byte 2
7
Byte 3
6
Byte 0 Byte 1 Byte 2
Byte 7 Start and stop measurement (if in Measurement Mode 2) 1 = Start of a measurement 2 = Stop of a measurement 3 = intermediate result
5
Byte 0 Byte 1 Byte 2 7
Byte 6
3
Byte 0 Byte 1 Byte 2 0
Byte 5
2
Byte 0 Byte 1 Byte 2
7
Byte 4
1
Byte 0 Byte 1 Byte 2
7
Byte 3
Byte 5 Byte 6 Mask for PGNs of PDU2 format to be send, if bit (value of which corresponds wit PS of PDU2) is TRUE, then the PGN will be send. Byte 5
Byte 6
Byte 7 transmission intervall of all PGNs of PDU2 format in seconds 0 = as soon as new value is available > 0 = Intervall in seconds (Default = 10) Byte 7 0x55 = Reboot the device
page 1 / 7
PDU 2
PDU2
Device address (Node ID): Direct Priorit R DP PF PS ion y Transmit
Type
10 SA
PGN
29Bit ID (dez)
29Bit ID (hex)
7
0
0
255
0
10
65280
486473738
1CFF000A
7
0
0
255
1
10
65281
486473994
1CFF010A
Byte 0
Byte 2
Byte 3
Internal time stamp of the measurement
Byte 0 PD U2 Tra ns mit
Byte 1
Byte 1
Byte 2
Byte 3
PDU2
Transmit
PDU2
Transmit
Byte 0
7
0
0
255
2
10
65282
486474250
1CFF020A
0
0
255
3
10
65283
486474506
1CFF030A
Byte 1
Byte 2
Byte 5
Byte 6
Byte 7
Intervall
ISO 4µm
ISO 6µm
ISO 14µm
ISO 21µm
default: 10 seconds
Byte 4
Byte 5
Byte 6
Byte 7
SAE 4µm
SAE 6µm
SAE 14µm
SAE 21µm
SAE-Standard coding: Offset of two in order to represent 000, 00 and 0, valid for all classes 0 = SAE 000 1 = SAE 00 2 = SAE 0 3 = SAE 1 4 = SAE 2
Internal time stamp of the measurement
7
Byte 4
Byte 3
Byte 4
Byte 5
Internal time stamp of the measurement
Byte 0
Byte 1
Byte 2
default: 10 seconds
Byte 6 GOST 17216
Byte 3
Byte 4 Öl-Zustandsbitsbits
Byte 5 Messbits
Byte 6 Sensorstatusbits
Byte 7 default: 10 seconds
NAS
Byte 7 Temperatur
Bit 0: Laser current high (I >2,8mA)
Current internal time (operating hours, in seconds)
Bit 0: measurement in progress Bit 1: measurement type Bit 0: concentration auto (time controlled) threshold exceeded (>= ISO Bit 2: measurement type I/O 23) (digital input) Bit 3: measurement type Bit 1: high flow manual (>500ml/min) (Button/RS232/CANopen/J1 939) Bit 2: low flow (=ISO(i)) (corresponds with alarmLED) Bit 7: temperature alarm triggered
Bit 1: Laser current low (I4V) Bit 3: Photodiode voltage low (U80°C)
Device temperature resolution 1bit/K Offset: 40°C (0 = -40°C; 40 = 0°C; 140 = 100°C)
default: 10 seconds
Bit 5: Temperature low (T= ISO 23)
Operational Range
Resolution
0 to 1 Bit, 1 4294967290 second 1 Bit, 1 Ordinal numeral 1 Bit, 1 0 to 23 Ordinal numeral 1 Bit, 1 0 to 23 Ordinal numeral 1 Bit, 1 0 to 23 Ordinal numeral 0 to 23
Offset
Units
Date SPN Status of Date SPN Status of SPN Doc PGN Doc was added SPN was SPN to PGN addition to added/modifi PGN ed
0 seconds
05-Mai-14
05.05.2014
0
Ordinal numeral
05-Mai-14
05.05.2014
0
Ordinal numeral
05-Mai-14
05.05.2014
0
Ordinal numeral
05-Mai-14
05.05.2014
0
Ordinal numeral
05-Mai-14
05.05.2014
Ordinal 2 numeral
05-Mai-14
05.05.2014
0 to 255
0 to 23
1 Bit, 1 Ordinal numeral
0 to 255
0 to 23
1 Bit, 1 Ordinal numeral
2
Ordinal numeral
05-Mai-14
05.05.2014
0 to 255
0 to 23
1 Bit, 1 Ordinal numeral
2
Ordinal numeral
05-Mai-14
05.05.2014
0 to 255
0 to 23
1 Bit, 1 Ordinal numeral
2
Ordinal numeral
05-Mai-14
05.05.2014
0 to 255
0 to 13
1 Bit, 1 Ordinal numeral
1
Ordinal numeral
28-Aug-14
28.08.2014
0 to 255
0 to 17
1 Bit, 1 Ordinal numeral
1
Ordinal numeral
28-Aug-14
28.08.2014
0 to 4294967295
0 to 1 Bit, 1 4294967290 second
0 Sekunde 05-Mai-14
05.05.2014
0 to 255
0 to 15
1 Bit
0
05-Mai-14
05.05.2014
0 to 255
0 to 127
1 Bit
0
05-Mai-14
05.05.2014
0 to 255
0 to 63
1 Bit
0
05-Mai-14
05.05.2014
0 to 255
0 to 250
1 Bit, 1 Kelvin
0 to 16777215
0 to 255 0 to 4294967295 0 to 4294967295
0 to 999999 1 Bit 1 Bit, 1 0 to 3599 second 1 Bit, 1 0 to 86399 second 0 to 250 1 Bit 0 to 1 Bit, 1 hour 4294967290 0 to 1 Bit, 1 hour 4294967290
0 to 255
0 to 250
1 Bit
0 to 255
0 to 250
0 to 255 0 to 255
Bit 1: high flow (>500ml/min) 65283 OPCom II Data
8
default: 10 seconds
8 520204 Öl-Zustandsbitsbits Bit 2: low flow (=ISO(i)) measurement in progress measurement type auto (time controlled) measurement type I/O (digital input) measurement type manual (Button/RS232/CANopen/J1939) Alarm mode: Filter / Standard Power-Up Alarm concentration (corresponds with alarm-LED) temperature alarm triggered Laser current high (I >2,8mA)
Bit 1: Laser current low (I4V) Bit 3: Photodiode voltage low (U80°C) Bit 5: Temperature low (T