Replacement Parts List No. 055237700 Rev. C 1/2013
Applied Decentralized Products Water Source Heat Pump FCV, FCG & FCW Sizes 048 & 060 Vintage A
To find your Daikin McQuay parts distributor, call 1-800-377-2787 or visit www.DaikinMcQuay.com
Contents Parts List Revision History ................................................................................................................. 3 Nomenclatures Serial Number................................................................................................................................. 4 Model Number................................................................................................................................ 4 Field Installed Accessories Thermostats and Subbases for Electromechanical Control Units.................................................. 5 Thermostats and Subbases for Mark IV Control Units................................................................... 5 Thermostat Accessories................................................................................................................. 6 Hoses & Valves............................................................................................................................... 6 Filters and Filter Components........................................................................................................ 6 Unit Accessories............................................................................................................................. 7 Refrigeration Circuit Diagram.......................................................................................................................................... 8 Components............................................................................................................................. 9, 10 Fan and Housing Assembly Diagram........................................................................................................................................ 11 Components................................................................................................................................. 12 Control Box Accessory & Standard Control Layout.......................................................................................... 13 MicroTech Control Layout............................................................................................................. 14 Components........................................................................................................................... 15, 16 Panels and Cabinet Assembly Diagram........................................................................................................................................ 17 Components................................................................................................................................. 18 Critical Parts List......................................................................................................................... CPL1
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 2
Parts List Revision History
Revision Date Description A 6/98 Updated to OnLine format. Added Revision History page. Page 15 Corrected part number for 208-230/60/3 Compressor Contactor. B 11/03 Page 9 - Bubble #5 size 048 part number was changed from 60676202 to 60676204 and size 060 was changd from 60676201 to60676203. C 1/13 Reformat to current standards. Change PM6.5 to CS6. Change p/ns to 9 Digits. Page 4- Added Serial Number (2/1999 to present). CPL1- Add Critical Parts List.
McQuay International, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 3
Nomenclatures Serial Number (until 2/1999) 7 U A 00000 00 PLANT IDENTIFICATION NUMBER 7 = Auburn
ENGINEERING REVISION SERIAL NUMBER
YEAR MANUFACTURED S = 1987 T = 1988 U = 1989 Etc.
MONTH MANUFACTURED A = January B = February C = March D = April E = May F = June G = July H = August J = September K = October L = November M = December
Serial Number (2/1999 to present) AUB
U
09
05
00148
Plant Identification Abbreviation AUB = Auburn
Serial Number (build sequence)
U= Unit
Week of Manufacture Year of Manufacture 08= 2008 09= 2009 etc.
Model Number FCV 048A E G L DIGITS 1-3 MODEL TYPE FCV = Floor Concealed Vertical Water Source Heat Pump FCG = Floor Concealed Vertical Cooling Only FCW = Floor Concealed Vertical Extended Range Heat Pump
DIGIT 9 VOLTAGE A = 115/60/1 G = 208-230/60/1 N = 265/60/1 F = 208-230/60/3 T = 460/60/3 W = 575/60/3 J = 230/50/1 Q = 380/50/3
DIGITS 4-7 UNIT SIZE / VINTAGE 007A = 7,100 Nominal Cooling Btuh 009A = 8,800 Nominal Cooling Btuh 012A = 12,500 Nominal Cooling Btuh 015A = 14,000 Nominal Cooling Btuh 019A = 19,500 Nominal Cooling Btuh 024A = 24,500 Nominal Cooling Btuh 030A = 30,000 Nominal Cooling Btuh 036A = 36,500 Nominal Cooling Btuh 042A = 41,000 Nominal Cooling Btuh 048A = 47,000 Nominal Cooling Btuh 060A = 61,500 Nominal Cooling Btuh
WSHP; FCV,FCG,FCW 048-060 Vintage A
DIGIT 10 RETURN AIR ARRANGEMENT L = Left Hand Return R = Right Hand Return
DIGIT 8 CONTROL SYSTEM E = Electromechanical Control M = Mark IV Control C = MicroTech Control
Rev. C 1/13
RPL 055237700 / Page 4
Field Installed Accessories Thermostats & Subbases for Electromechanical Control Unit Description
Part Number
STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Thermostat Honeywell T874/Q674. LED for "Service." Mounts horizontal. Subbase System "Off-Auto" switch and fan "On-Auto" switch. DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE WITH NIGHT SETBACK. Honeywell T874/Q674. LED for "Service." Thermostat Mounts horizontal. Requires factory installed night setback relay or field installed night setback or night setback/demand control relay. Night setback bulb set 8o F below day heating setpoint. System "Off-Auto" switch and fan Subbase "On-Auto" switch. Requires minimum of 6 wires. PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-1000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. Digistat HP-1000DC/BO. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. Honeywell T862. 1
803005245 (Includes subbase) 060687201 060687401 060687301
060687401 0612129011 (Includes subbase) 061212801 (Includes subbase)
Replaces 060602301 (Digistat HP-2000DC) Thermostat.
Thermostats & Subbases for Mark IV Control Unit Description
Part Number
STANDARD MANUAL CHANGEOVER THERMOSTAT & SUBBASE. Honeywell T834C with no LED. Mounts vertically. System "Heat-Off-Cool" switch and fan. "On-Auto" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE. Thermostat Honeywell T874/Q674. LED for "Service." Mounts horizontal. Subbase System "Off-Auto" switch and fan "On-Auto" switch. STANDARD MANUAL & AUTO CHANGEOVER THERMOSTAT & Thermostat SUBBASE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Subbase System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. DELUXE AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE Thermostat WITH NIGHT SETBACK AND OVERRIDE. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. Night setback bulb set 12o F below day heat setpoint. System "Off-Auto" Subbase switch and fan "On-Auto-Override" switch. STANDARD AUTOMATIC CHANGEOVER THERMOSTAT & SUBBASE Thermostat FOR OPERATING TWO UNITS. Honeywell T874/Q674. LED for "Service." Subbase Mounts horizontal. System "Off-Auto" switch.
803005245 (Includes subbase)
PROGRAMMABLE MICROELECTRONIC THERMOSTAT. Digistat HP-1000DC. Auto or manual changeover. Mounts horizontal. System "Off-Auto" switch, temp. "Heat-Auto-Cool" switch and fan "On-Auto" switch. PROGRAMMABLE MICROELECTRONIC THERMOSTAT WITH REMOTE SENSOR. "Heat-Auto-Cool" switch and fan "On-Auto" switch.
0612129011 (Includes subbase)
060685301 060684801 060685301 060684901 061202402 2 061202601 060685201 060684701
061212801 (Includes subbase)
Replaces 060602301 (Digistat HP-2000DC) Thermostat. Deluxe Thermostat was 060685501 (T874D1686) which has been phased out. When replacing 060685501 with 061202401, must also replace the Subbase from 060684801 to 061202601. Thermostat 061202401 is not compatible with 060684801 (Q674C1298) Subbase. 1 2
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 5
Field Installed Accessories Thermostat Accessories
Description
Part Number
NIGHT SETBACK THERMOSTAT. Honeywell T822. Mounts vertically. No LED. No switches. For applications requiring a separate NSB stat. UNIVERSAL THERMOSTAT GUARD. Honeywell TG500A. Clear plastic with ring base, lock and keys. DELUXE LOCKING COVER FOR T874/Q674 THERMOSTATS. Honeywell TG504A. Applies only to T874/Q674 thermostats. Replaces standard thermostat cover. Includes cover, lock and keys. ADAPTER PLATE FOR T874/Q674 THERMOSTATS. Allows for horizontal thermostat to be mounted on a vertical junction box 7-DAY TIME CLOCK. OVERRIDE TIMER - 1 HOUR. OVERRIDE TIMER - 6 HOUR.
803005180 802005426 060684501 802007673 802005716 802005717 802005718
Valves, Hoses and Filters Description STANDARD SUPPLY OR RETURN HOSE. Rubber hose with MPT swivel hydraulic fittings on each end. Order two per unit. FIRE RATED SUPPLY OR RETURN HOSE. Stainless steel, braided hose with one MPT and one MPT swivel fitting. Order 2 per unit. CONDENSATE HOSE ASSEMBLY. Requires trap by others. Order one per unit. Includes fitting to be soldered on unit. BALL VALVE. Combination shutoff and balancing valve with memory stop. Order two per unit.
Part Number 2' long, 3/4" I.D. (Size 048) 2' long, 1" I.D. (Size 060) 3' long, 3/4" I.D. (Size 048) 3' long, 1" I.D. (Size 060) 2' long, 3/4" I.D. (Size 048) 2' long, 1" I.D. (Size 060) 3' long, 3/4" I.D. (Size 048) 3' long. 1" I.D. (Size 060) Clear plastic, 38" long Fire rated, 24" long Fire rated, 36" long 3/4" FPT (Size 048) 1" FPT (Size 060)
802025405 802025414 802025406 802025415 802025602 802025611 802025603 802025612 060687701 060688801 060688802 802026098 802026109
Filters & Filter Components Description
2" THICK THROWAWAY FILTER. Fits into 2" thick filter rack. Must order in multiples of 12. 1" THICK THROWAWAY FILTER. Replacement for standard filter. Must order in multiples of 12. 1" THICK CLEANABLE FILTER. Must order in multiples of 12. 2" THICK PLEATED FILTER, 35% EFFICIENT. Must order in multiples of 12. RETURN AIR DUCT COLLAR & TWO INCH FILTER RACK.
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
Part Number 060687110 060604809 060687010 060759810 060917405
RPL 055237700 / Page 6
Field Installed Accessories Unit Accessories Description
Part Number
SHUTDOWN RELAY KIT FOR ELECTROMECHANICAL CONTROL UNITS. For shutdown of the unit from an external 24 volt AC power source. Relay mounts at control box.
061019403
NIGHT SETBACK RELAY KIT FOR ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from an external 24 volt AC power source. Relay mounts at control box. Operation requires ACO stat with built-in NSB or a separate NSB stat.
802005728
NIGHT SETBACK/DEMAND CONTROL RELAY KIT - ELECTROMECHANICAL UNITS. Relay to put unit into NSB mode from one 24 volt AC power source and to put unit into load shed mode from another 24 volt AC power source (3 total wires required). Relay mounts at control box, operation requires ACO stat with built-in NSB or separate NSB stat. RANDOM START RELAY - ELECTROMECHANICAL CONTROL. 115, 208/230, 265V UNITS. Time delay relay to delay compressor startup when coming off night 460, 575V operation and to not allow all units to start at the same time. CONDENSATE OVERFLOW SAFETY SWITCH - ELECTROMECHANICAL CONTROL UNITS. Float switch in drain pan to shut down compressor operation when pan fills.
802005496
AUXILIARY RELAY. 24 volt DC relay to be wired to low voltage terminal block to allow a set of SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate.
803005073
BOILERLESS SYSTEM KIT. Must be Mark IV control unit. Includes electronics and sensor to lock out compressor operation at 50o F to 60o F EWT and provide SPNO contacts to a field supplied electric heater control system.
060844701
LOGIC LINK II. Must be Mark IV control unit. Includes electronics, ACO stat and subbase for adjustable night setback and setup and compressor only shutdown (demand control/load shed) from a 24 volt AC external power source. Also includes 1 hour override control at the thermostat.
060845001 (NLA)
LOGIC LINK II WITH BOILERLESS SYSTEM. Incorporates both Logic Link and Boilerless System control in one package. Includes ACO stat and subbase, and EWT sensor. Requires 24 volt AC external power source. MULTIPLE UNIT CONTROL PANEL. Allows master unit to be controlled Master & 1 Slave by any thermostat. Slave units "follow" with paralleled operation. Not Master & 3 Slaves Kit recommended with Boilerless System. MOTORIZED VALVE. Includes prewired valve/operator, 3 foot conduit Unit Size 3/4" FPT 048 assembly with leads and quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum operating pressure. Requires Unit Size 1" FPT 060 control relay. See below. CONTROL RELAY FOR MOTORIZED VALVE.
060846001 (NLA)
INTERFACE KIT. For other electronic or DDC controlIers.
Heat, Cool & Fan Ctrl
061047701
Heat, Cool & Fan Ctrl & Fault Relay
061047801
802007881
802005498 803005260
803005159 059002819 060977301 060977201 060977201
NLA = Part Numbers 060845001 & 060846001 are no longer available as a kit. Individual parts may be available.
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 7
Refrigeration Circuit Diagram
TO WATER REGULATING VALVE (OPTION)
2 6
7 5
4 8
3 10 11
9
12 1
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 8
Refrigeration Circuit Components
208/60/1 230/60/1
575/60/3 380/50/3
575/60/3 380/50/3
Part Number
208/60/3 230/60/3 460/60/3
Description
208/60/1 230/60/1
Bub. Num.
208/60/3 230/60/3 460/60/3
060
048
1 Compressor 1 060604201 1 1 1 Compressor 2 60743901K 1 1 1 Compressor 1 060604203 1 1 1 Compressor 2 60743903K 1 1 1 Compressor 1 060604202 1 1 Compressor 2 60743902K 1 1 Compressor 1 060604204 1 1 Compressor 2 060743904 1 1 Compressor 1 802003406 1 1 1 Compressor 1 802003404 1 1 1 Compressor 2 802003412 1 1 1 1 Compressor 802003405 1 1 1 Compressor 2 802003413 1 1 1 Compressor 2 802003414 1 1 Compressor 1 802003407 1 1 Compressor 2 802003415 1 1 Compressor 802003410 1 N/S N/S N/S N/S N/S 2 2 2 2
Threaded Plug, 1/2" - 13 802028117 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Capacitor, Compr., 40 MFD 440V 802007858 1 1 Capacitor, Compr., 55 MFD 440V 060630902 1 1 Protector, Terminal 802007316 1 1 1 1 Bracket, Capacitor 050010570 1 1 1 1
N/S N/S 3 3 4 4 5 5
Flanged Nut 802012035 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Spring Nut, U Type 802017006 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Coaxial Coil Coaxial Coil Coaxial Coil Coaxial Coil
Copper 060836301 1 1 1 1 1 1 1 Cupronickel 060836302 1 1 1 1 1 1 1 Copper 060602501 1 1 1 1 1 1 1 Cupronickel 060602502 1 1 1 1 1 1 1
Fin Tubular Coil 060916401 1 1 1 1 1 1 1 Fin Tubular Coil 060929301 1 1 1 1 1 1 1 Capillary (33 X .059 X .112) 802001041 6 6 6 6 6 6 6 Capillary (47 X .059 X .112) 802001173 8 8 8 8 8 8 8 Strainer / Distributor 060676204 1 1 1 1 1 1 1 Strainer / Distributor 060676203 1 1 1 1 1 1 1
N/S = Not shown on diagram 1 Not on Extended Range units. (Not on units with Model No. digits 1-3 = FCW). 2 Extended Range units only. (Units with Model No. digits 1-3 = FCW).
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
Continued on next page.
RPL 055237700 / Page 9
Refrigeration Circuit Components
208/60/1 230/60/1
575/60/3 380/50/3
575/60/3 380/50/3
Part Number
208/60/3 230/60/3 460/60/3
Description
208/60/1 230/60/1
Bub. Num.
208/60/3 230/60/3 460/60/3
060
048
6
Reversing Valve 4 802026142 1 1 1 1 1 1 1 1 1 1 1 1 1 1
7
Solenoid, Reversing Valve 3
24V 802026121 1 1 1 1 1 1 1 1 1 1 1 1 1 1
8
Switch, High Pressure 802005813 1 1 1 1 1 1 1 1 1 1 1 1 1 1
9
Switch, Low Pressure 060605501 1 1 1 1 1 1 1 1 1 1 1 1 1 1
10 10
Thermostat, Low Temp Cutout 1 802005724 1 1 1 1 1 1 1 1 1 1 1 1 1 1 2 Thermostat, Low Temp Cutout 802005979 1 1 1 1 1 1 1 1 1 1 1 1 1 1
11
Speed Clip, Thermostat 802017215 1 1 1 1 1 1 1 1 1 1 1 1 1 1
12 12 N/S
Accumulator 2 802025539 1 1 1 1 1 1 1 Accumulator 2 060721901 1 1 1 1 1 1 1
N/S
Grommet, Compressor Mounting 5 802003084 4 4 4 4 4 4 4 4 4 4 4 4 4 4
N/S N/S N/S
Sleeve, Compressor Grommet 5 031313600 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Sleeve, Compressor Grommet 6 044074900 4 4 4 4 4 4 4 4 4 4 4 4 4 4
N/S
Spacer, Top, Compressor Mtg. 6 060687801 4 4 4 4 4 4 4 4 4 4 4 4 4 4
N/S
Spring, Compressor Mounting 6 060688001 4 4 4 4 4 4 4 4 4 4 4 4 4 4
N/S N/S
Valve, Water Regulating 1,7 802026199 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Valve, Water Regulating 2,7 802026201 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Flanged Nut Compr., Mounting
802012035 4 4 4 4 4 4 4 4 4 4 4 4 4 4
Spacer, Lower Compressor Mtg. 6 060687901 4 4 4 4 4 4 4 4 4 4 4 4 4 4
N/S = Not shown on diagram 1 Not on Extended Range units. (Not on units with Model No. Digits 1-3 = FCW). 2 Extended Range units only. (Units with Model No. Digits 1-3 = FCW). 3 Heat Pump units only. (Units with Model No. Digits 1-3 = FCV or FCW). 4 When replacing reversing valve, use 066533501 and solenoid 066541901. 5 Standard Construction units only. 6 Extra Quiet Construction units only. 7 Used only on units with Water Regulating Valve Option.
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 10
Fan and Housing Assembly Diagram
Blower Panel (For Blower Panel Assembly see Panels & Cabinet Section.)
14 19
20
15 17
16 18 13
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 11
Fan and Housing Assembly Components
380/50/3 208/60/1
230/60/3 460/60/3 575/60/3
460/60/3 575/60/3 380/50/3
13 Motor
208/60/3
Part Number
208/60/1 230/60/1
Description
Bub. Num.
230/60/1 208/60/3 230/60/3
060
048
3/4 HP 060704701 1 1 1 1 13 Motor 3/4 HP 060704702 1 13 Motor 3/4 HP 060704703 1 13 Motor 3/4 HP 060704704 1 13 Motor 3/4 HP 060915001 1 1 1 1 13 Motor 3/4 HP 060915002 1 13 Motor 3/4 HP 060915003 1 13 Motor 3/4 HP 060915004 1 N/S Motor Mount 062200601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 14 Run Capacitor, Motor 15 MFD 370V 802007844 1 1 1 1 1 1 1 1 1 1 1 1 14 Run Capacitor, Motor 10 MFD 370V 802007063 1 1 15 Bracket, Capacitor 050010570 1 1 1 1 1 1 1 1 1 1 1 1 1 1 16 16
Blower Housing Weldment 060699605 1 1 1 1 1 1 1 Blower Housing Weldment 060899501 1 1 1 1 1 1 1
17 17
Inlet Ring 060829001 1 1 1 1 1 1 1 Inlet Ring 060899101 2 2 2 2 2 2 2
18 18 19
Wheel, Blower 802000039 1 1 1 1 1 1 1 Wheel, Blower 060899201 1 1 1 1 1 1 1 Protector Terminal 802007316 1 1 1 1 1 1 1 1 1 1 1 1 1 1
N/S Blower Cutoff 060899001 1 1 1 1 1 1 1 20 Band, Motor Mounting 802009140 1 1 1 1 1 1 1 N/S Arm, Motor Mounting 060899401 3 3 3 3 3 3 3 N/S = Not shown on diagram
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 12
Control Box Standard Control Layout
50HZ TERMINAL BLOCK & BRACKET
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 13
Control Box Layout - MicroTech Control MicroTech Control Layout
31 23
45
22 27
26
39 24 34 25
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 14
Control Box Components
380/50/3 208/60/1
230/60/3 460/60/3 575/60/3
208/60/3
Part Number
460/60/3 575/60/3 380/50/3
22
Description
208/60/1 230/60/1
Bub. Num.
230/60/1 208/60/3 230/60/3
060
048
22
Barrier, Control Box 1 060816201 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Barrier, Control Box 2 060981901 1 1 1 1 1 1 1 1 1 1 1 1 1
P.C. Board, Mark IV 3 Circuit Board, Electromechanical 1 Circuit Board, Microtech 2 Sensor Assembly, Temperature 2
23 23 23 N/S
060638802 1 1 1 1 1 1 1 1 1 1 1 1 1 1 060679201 1 1 1 1 1 1 1 1 1 1 1 1 1 1 060959401 1 1 1 1 1 1 1 1 1 1 1 1 060988402 1 1 1 1 1 1 1 1 1 1 1 1
24 25 26
Block, Terminal, 3-Pole 2 049759001 2 2 2 2 2 2 2 2 2 2 2 2 2 Block, Terminal, 4-Pole 049759002 1 1 1 1 1 1 1 1 1 1 1 1 Block, Terminal, 5-Pole 2 049759003 1 1 1 1 1 1 1 1 1 1 1 1
27 27
Panel, Mounting, PC Board 060981601 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Panel, Mounting, PC Board 2 060981701 1 1 1 1 1 1 1 1 1 1 1 1
28 28 28
Stand-Off 2 802028130 1 1 1 1 1 1 1 1 1 1 1 1 Stand-Off 3 802028130 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Stand-Off 1 802028130 4 4 4 4 4 4 4 4 4 4 4 4 4 4
29 29 29
Nut, Nylon 2 802012415 1 1 1 1 1 1 1 1 1 1 1 1 3 Nut, Nylon 802012415 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Nut, Nylon 1 802012415 4 4 4 4 4 4 4 4 4 4 4 4 4 4
30
Control Box 060981501 1 1 1 1 1 1 1 1 1 1 1 1 1 1
31
Screw, Tapping 033153700 1 1 1 1 1 1 1 1 1 1 1 1 1 1
N/S Washer, Cupped 030388700 1 1 1 1 1 1 1 1 1 1 1 1 1 1 32 32 32 32 32
Contactor, Comp. Contactor, Comp. Contactor, Comp. Contactor, Comp. Contactor, Comp.
803005105 1 1 1 1 803005233 1 1 1,3 803005193 1 1 1 1 1,2,3 803005222 1 1 1 1 2 803005223 1 1 1,3
1,3
N/S = Not shown on diagram. 1 = Electromechanical Control units only. (Units with Model No. Digit 8 = E). 2 = MicroTech Control units only. (Units with Model No. Digit 8 = C). 3 = Mark IV Control units only. (Units with Model No. Digit 8 =M).
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
Continued on next page.
RPL 055237700 / Page 15
Control Box Components
Relay, Fan 2 33 Relay, Fan 33 Relay, Fan
380/50/3
230/60/3 460/60/3 575/60/3
460/60/3 575/60/3 380/50/3
33
Part Number
208/60/3
Description
208/60/1 230/60/1
Bub. Num.
208/60/1 230/60/1 208/60/3 230/60/3
060
048
24VAC 060949501 1 1 1 1 1 1 1 1 24V SPDT 802005819 1 1 1 1 3PDT 802005906 1 1
34 Bracket, Control Option Mounting 060830301 1 1 1 1 1 1 1 1 1 1 34 Bracket, Control Option Mounting 061049101 1 1 1 35 35
Relay, Random Start 1,4 802005496 1 1 1 1 1 1 1 1 1 1 1 1 Relay, Random Start 1,4 802005498 1 1
36
Relay, Shutdown 1,5
37 37
Relay, Night Setback 1,6 802005728 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Relay, Demand Control 1,7 802007881 1 1 1 1 1 1 1 1 1 1 1 1 1 1
38
Relay, Auxiliary 8
39 39 39 39
Relay, Timed Output 2 Relay, Boilerless System 2 Relay, Fresh Air Damper 2 Relay, Motorized Valve 2
N/S
Suppressor/Diode Assy. 2 061073402 1 1 1 1 1 1 1 1 1 1 1 1
24V 061019403 1 1 1 1 1 1 1 1 1 1 1 1 1 1
24V BD 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 1 24V 24V 24V 24V
802005206 1 1 1 1 1 1 1 1 1 1 1 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1 802005206 1 1 1 1 1 1 1 1 1 1 1 1
40 Mount, Terminal Block 061131001 1 1 41 Terminal Block 802007432 4 4 42 End, Terminal Block 802007431 1 1 43 Terminal, Lug 802007744 1 1 44 Transformer 44 Transformer 44 Transformer 45
208/240V - 24V 060614101 1 1 1 1 1 1 1 1 1 1 480V - 24V 060676001 1 1 575V - 24V 060676101 1 1
Transformer 2
24V 060949301 1 1 1 1 1 1 1 1 1 1 1 1
N/S = Not shown on diagram 1 = Electromechanical Control units only. (Units with Model No. digit 8 = E). 2 = MicroTech Controller units only. (Units with Model No. digit 8 = C). 3 = Mark IV Control units only. (Units with Model No. digits 8 = M). 4 = Only on units with Random Start Relay Option. 5 = Only on units with Shutdown Relay Option. 6 = Only on units with Night Setback Option. 7 = Only on units with Demand Control Option. 8 = Only on units with Auxiliary Relay Option & without MicroTech Controller.
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 16
Panels and Cabinet Assembly Diagrams
54 59
60
52 56
66 65 64
57
55 51
58 63 62
50 53
62
61
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 17
Panels and Cabinet Assembly Components
50 51
380/50/3 208/60/1 230/60/1 208/60/3 230/60/3
230/60/3 460/60/3 575/60/3
Part Number
060 460/60/3 575/60/3 380/50/3
50
Description
208/60/3
Bub. Num.
208/60/1 230/60/1
048
Base Pan 1 060911206 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Base Pan 2 060911306 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Drain Pan 060914103 1 1 1 1 1 1 1 1 1 1 1 1 1 1
52
Panel, Filler 060816002 1 1 1 1 1 1 1 1 1 1 1 1 1 1
53
Panel, Left-Front Corner 060814902 1 1 1 1 1 1 1 1 1 1 1 1 1 1
54
Panel, Wrap 060815102 1 1 1 1 1 1 1 1 1 1 1 1 1 1
55
Panel, Left-Rear Corner 060815002 1 1 1 1 1 1 1 1 1 1 1 1 1 1
56
Panel, Bulkhead 060815201 1 1 1 1 1 1 1 1 1 1 1 1 1 1
57
Panel, Upper Access 060815602 1 1 1 1 1 1 1 1 1 1 1 1 1 1
58 59
Panel, Lower Access 060815702 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Panel, Back Access 060815802 1 1 1 1 1 1 1 1 1 1 1 1 1 1
60 60 60 60
Panel, Blower Panel, Blower Panel, Blower Panel, Blower
61
Panel, Evaporator Coil 060815902 1 1 1 1 1 1 1 1 1 1 1 1 1 1
62 63
Channel, Filter 060816402 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Air Filter, Throwaway 060604809 2 2 2 2 2 2 2 2 2 2 2 2 2 2
64 N/S
Switch, Condensate Overflow 3,4 803005260 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Wire, Condensate Overflow 5,6 056794401 1 1 1 1 1 1 1 1 1 1 1 1 1 1
65
Box, Control 060981501 1 1 1 1 1 1 1 1 1 1 1 1 1 1
66
Support Coil 060816301 1 1 1 1 1 1 1 1 1 1 1 1 1 1
Left Right Left Right
061216402 1 1 1 1 1 1 1 061216302 1 1 1 1 1 1 1 061216202 1 1 1 1 1 1 1 061216102 1 1 1 1 1 1 1
N/S = Not shown on diagram. 1 Standard Construction units only. 2 Extra Quiet Construction units only. 3 Electromechanical Control units only. (Units with Model No. Digit 8 = E). 4 Used only on units with Condensate Overflow Switch Option. 5 MicroTech Controls (units with Model No. Digit 8 = C). 6 Mark IV Controls (units with Model No. Digit 8 = M).
WSHP; FCV,FCG,FCW 048-060 Vintage A
Rev. C 1/13
RPL 055237700 / Page 18
Critical Daikin McQuay OEM Parts Are What Your Daikin McQuay HVAC Unit Needs! Applied Decentralized Products Water Source Heat Pump FCV, FCG & FCW Sizes 048 & 060 Vintage A CRITICAL COMPONENTS MODEL UNIT SIZE VOLTAGE CONTROLS Control Board Electromechanical ALL ALL N/A Control Board Microtech 120 ALL ALL N/A Control Board Mark IV/DC ALL ALL N/A COMPRESSOR Compressor 43200 BTU FCV, FCG 048 208/230/60/1 Compressor 43200 BTU FCW 048 208/230/60/1 Compressor 43200 BTU FCV, FCG 048 208/230/60/3 Compressor 43200 BTU FCW 048 208/230/60/3 Compressor 43200 BTU FCV, FCG 048 460/60/3 Compressor 43200 BTU FCW 048 460/60/3 Compressor 43200 BTU FCV, FCG 048 575/60/3 Compressor 43200 BTU FCW 048 575/60/3 Compressor 43200 BTU FCV, FCG 048 380/50/3 Compressor 57100 BTU FCV, FCG 060 208/230/60/1 Compressor 57100 BTU FCW 060 208/230/60/1 Compressor 57100 BTU FCV, FCG 060 208/230/60/3 Compressor 57100 BTU FCW 060 208/230/60/3 Compressor 57100 BTU FCV, FCG 060 460/60/3 Compressor 57100 BTU FCW 060 460/60/3 Compressor 57100 BTU FCV, FCG 060 575/60/3 Compressor 57100 BTU FCW 060 575/60/3 Compressor 57100 BTU ALL 060 380/50/3 FAN MOTOR Motor 3/4 HP ALL 048 208/230/60/1/3 Motor 3/4 HP ALL 048 460/60/3 Motor 3/4 HP ALL 048 575/60/3 Motor 3/4 HP ALL 048 380/50/3 Motor 3/4 HP ALL 060 208/230/60/1/3 Motor 3/4 HP ALL 060 460/60/3 Motor 3/4 HP ALL 060 575/60/3 Motor 3/4 HP ALL 060 380/50/3 FAN HOUSING & WHEEL Blower Housing ALL 048 N/A Blower Housing ALL 060 N/A Wheel, Metal CW ALL 048 N/A Wheel, Metal CW ALL 060 N/A REFRIGERATION CIRCUIT Reversing Valve FCV, FCW ALL N/A Reversing Valve Solenoid FCV, FCW ALL N/A
Call Your Local Daikin McQuay Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.DaikinMcQuay.com or Call 1-800-37PARTS 552377 Rev. C 1/2013
CPL Page 1 of 1
PART NUMBER 060679201 060959401 060638802 060604201 60743901K 060604203 60743903K 060604202 60743902K 060604204 060743904 802003406 802003404 802003412 802003405 802003413 802003406 802003414 802003407 802003415 802003410 060704701 060704702 060704703 060704704 060915001 060915002 060915003 060915004 060699605 060699501 802000039 060899201 802026142 802026121