Agilent Technologies Oscilloscopes

Agilent Technologies Oscilloscopes March 2011 Agilent Oscilloscopes - Industry’s Largest Portfolio Infiniium 600MHz – 80GHz DCA-X Series 90000 X-...
Author: Roy Shaw
13 downloads 1 Views 1MB Size
Agilent Technologies Oscilloscopes

March 2011

Agilent Oscilloscopes - Industry’s Largest Portfolio Infiniium 600MHz – 80GHz

DCA-X Series

90000 X-Series 90000 Series

Fastest Growing Scope Company Economy

InfiniiVision

20MHz – 200MHz

70MHz – 1GHz

Handheld

9000 Series

USB 7000 Series U2700 Series

U1600A Series

2000X Series

3000X Series

6000/6000L Series

September 1, 2010

Agilent 100 MHz / 200 MHz HH Scopes At A Glance Model

U1610A

U1620A

Bandwidth

100 MHz

200 MHz

Channel

2

2

Display

5.7” VGA TFT LCD color display (640 x 480 pixels)

Sampling rate

1 GSa/s (500 MSa/s for each channel)

2 GSa/s (1 GSa/s for each channel)

Recording length (Memory)

120 kpts / channel interleave (60 kpts for non-interleave channel)

2 Mpts / channel interleave (1 Mpts for non-interleave channel)

Meter Function Meter resolution

10,000 counts

Meter measurements

DCV, ACV, ACV+DCV, Diode, Continuity, Resistance, Capacitance, Temperature, Frequency User-ability

Local Language Graphic User Interface (GUI)

10 selectable languages: English, Francais, Deutsch, Italiano, Espanol, Portugues, Simplified Chinese, Traditional Chinese, Japanese, Korean

View mode

Indoor mode, Outdoor mode, Night vision Safety

Channel-to-channel isolation



Safety rating

CAT III 600 V

Ingress Protection

IP 41

Group/Presentation Title Month ##, 200X

World’s 1st HH Scope With VGA TFT LCD Display

5.7 inch VGA TFT LCD What it really means

How it benefits user?

VGA

4x more resolution

4x more details than QVGA

TFT LCD

A variant of liquid crystal display (LCD) that uses thin-film transistor (TFT) technology to improve image quality

Better image addressability and contrast to view waveform clearly Group/Presentation Title Month ##, 200X

Read Under All Lightning Conditions

Indoor mode

Outdoor mode

Night vision mode

Group/Presentation Title Month ##, 200X

See Signal Details Over Long Period Of Time 2 Mpts memory - for validation and debug:

Chasing down a problem View both problem effect and problem cause in a single acquisition

Characterizing the signal Maintain high signal resolution when zooming in, even after acquiring long periods of time

Page 6

Group/Presentation Title Month ##, 200X

InfiniiVision: 70 MHz-1GHz

InfiniiVision 70MHz – 1GHz

7000 Series

2000X Series

3000X Series

6000/6000L Series

September 1, 2010

Agilent InfiniiVision Series Engineered for Best Signal Visibility

Common Features: • MSO Models and Upgrades • Fast Waveform Update Rates • Deep & Responsive MegaZoom Memory

2000 X-Series

• High Resolution Display Intensity Gradation

3000 X-Series

• Hardware-based Serial Decode and Triggering

7000B Series

• Hardware-based Mask Testing • Segmented Memory

6000A Series Model

6000L Series

Unique Positioning

2000 X-Series 3000 X-Series

Lowest Price, WaveGen Fastest Update Rate, WaveGen 6000A Series Battery Option 6000L Series 1U High 7000B Series Highest Perf, Largest Display

* Half channel interleaved mode

• Search and Navigation

Bandwidth

Sample* Memory* Rate (max)

70MHz to 200MHz 100MHz to 500MHz 100MHz to 1GHz 100MHz to 1 GHz 100MHz to 1GHz

2 GSa/s 100 kpts 4 GSa/s 4 Mpts

50k /sec 1M /sec

2 or 4 2 or 4

8 optional 16 optional

4 GSa/s 4 GSa/s 4 GSa/s

100k /sec 100k /sec 100k /sec

2 or 4 2 or 4 2 or 4

16 optional 16 optional 16 optional

8 Mpts 8 Mpts 8 Mpts

Update Rate Scope Logic (max) Channels Channels

InfiniiVision 2000/3000 X-Series January 1, 2011 Page 8

Možnost vidět to, co na jiných osciloskopech zůstává skryto

8.5” WVGA obrazovka nabízí 2x větší zobrazovací plochu a 5x tolik pixelů Zpracování 1.000.000 průběhů / s

Paměť MegaZoom 4. generace

Agilent custom ASIC technology designed for market leading value.

Ne pouze osciloskop, ale 4 přístroje v jednom!

Osciloskop s nejrychlejším zpracováním signálu na trhu (1.000.000 stop / s) Logický analyzátor - 16 kanálů

Funkční a arbitrary generátor 20 MHz (DDS, 10 bit, 100 Msa/s, 5 kpts)

Protokolový analyzátor

Protokolový analyzátor Hardwarově akcelerované dekódování umožňuje protokolovou analýzu skutečně v reálném čase, korelovaně s časovým průběhem signálu, bez zpomalení činnosti osciloskopu. Možnost dekódování více sběrnic současně.



I2C/SPI



CAN/LIN



FlexRay



RS232/UART



I2S



MIL-STD 1553/ARINC 429

FlexRay trigger and decode

FlexRay eye diagram mask test

DSO InfiniiVisionX další měřicí aplikace • Digitální Voltmetr 3-místný digitální voltmetr používající osciloskopické vstupy

• Maskové Testy až 280.000 testů / s • Segmentovaná Paměť až 1.000 segmentů

• Analýza spínaných zdrojů • Advanced Math přídavné matematické funkce, filtry, trendy

• HDTV Video spouštění na highdefinition video signály

Infiniium: 600MHz - 80GHz DCA-X Series Up to 80 GHz

90000 X-Series

90000 Series

16 – 32 GHz

2.5 – 13 GHz

9000 Series 600 MHz – 4 GHz

September 1, 2010

Infiniium 9000 Series Key Applications

Embedded System Design Signal Integrity Compliance Verification Model

Analog Bandwidth

Max Sample Rate *)

Standard Memory *)

Analog Channels

DSO9064A

600 MHz

5 Gsa/s

20 Mpts

4

5 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

10 Gsa/s

20 Mpts

4

MSO9064A DSO9104A

1 GHz

MSO9104A DSO9254A

2.5 GHz

MSO9254A DSO9404A MSO9404A

4 GHz

Digital Channels

16

16

16

16

*) Sample Rate and Memory double in 2ch Mode

Engineered for broadest measurement capability September 1, 2010

Why buy the 9000 Series? The best 3 in 1 instrument – debug your design with a single tool • Industry-leading scope performance • High-performance logic analysis • Powerful, integrated protocol analysis

Broadest application selection (over 30) gives you an “Everything Analyzer” • • • •

Bus compliance, verification, and analysis InfiniiScan software triggers User-defined applications and functions Jitter analysis, equalization, de-embedding, and much more

Sized to fit your bench and budget • 15 inch display • Only 9 inches deep and only 26 pounds • Upgradeable memory, digital channels, bandwidth and apps

September 1, 2010

Why buy the 90000 Series? Superior signal integrity – shows the signal, not the scope • Lowest noise floor • Lowest trigger jitter • Agilent RF design expertise

Innovative probing – for your design • Industry-leading signal integrity – all the way to the probe tip • Flexible and comprehensive connection options

Designed for your application – today and tomorrow • Fully upgradeable, including bandwidth • Dozens of application packages expand your analysis

September 1, 2010

Infiniium 90000 X-Series Oscilloscopes Engineered for true analog bandwidth that delivers  The highest real-time scope measurement accuracy  Complete 30 GHz oscilloscope probing system  The industry’s most comprehensive application-specific measurement software Bandwidth upgradeable for investment protection 6 New Scope Models DSO/DSA91604A DSO/DSA92004A DSO/DSA92504A DSO/DSA92804A DSO/DSA93204A Analog Bandwidth (2 ch) 16 GHz 20 GHz 25 GHz 28 GHz 32 GHz Max Sample Rate (2 ch / 4 ch) 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s Std Memory *) 20M 20M 20M 20M 20M Max Memory 2 Gpts 2 Gpts 2 Gpts 2 Gpts 2 Gpts Noise @ 50mV/div 1.34 mV 1.53 mV 1.77 mV 1.89 mV 2.08 mV Jitter Measurement Floor 150 fs rms 150 fs rms 150 fs rms 150 fs rms 150 fs rms *) DSA model: 50M Std Memory, EZJIT Plus, SDA

Why buy the 90000 X-Series? The industry’s highest real-time scope measurement accuracy

• Highest true analog bandwidth (32 GHz) • Lowest oscilloscope noise floor (2.04 mV at 50 mV/div, 32 GHz) • Lowest jitter measurement floor (150 fs)

Industry’s first 30 GHz oscilloscope probing system • InfiniiMax III high-frequency probes with automatic AC calibration (PrecisionProbe) • Fully-integrated probe amplifier s-parameter correction • The industry’s first bandwidth-upgradable probe amplifier

Industry’s most comprehensive application-specific measurement software • Broadest range of jitter, triggering, analysis and display tools • Pre-built compliance testing software based on the expertise of our engineers on the standards committees • Support for emerging technologies including FibreChannel, SAS 12G or MIPIMPhy

September 1, 2010

True Analog Bandwidth that Delivers

The Industry’s Highest Measurement Accuracy The Final Result: 1. Over 25% larger eye height and width measurements 2. Lower total jitter measurements 3. More detail is captured in the eye, that is buried in other oscilloscope noise floor

20 GHz versus 20 GHz at 10.4 Gbps j-BERT PRBS^7 signal, lowest setting of ISI added via the jBert

Innovative Chipset Designed in Agilent’s Proprietary Highspeed High-Voltage InP HBT Process  Low noise and high measurement accuracy

25 25

InP SHBT & GaAs

Agilent’s Proprietary InP HBT Process Enabled by Unique HFTC GaAsSb Epi

20 20

BVceo (Volts)

UM

InP DHBT

15 15

Agilent HB2A Si & SiGe

TRW

 Significant margin in speed and linearity Agilent & SFU Research

NTT

55

HRL IBM

00

 Superior pulse distortion control, enhanced fidelity

Agilent HB2B

NGST GCS

10 10

 2X usable voltage

0 0

50 50

Jazz Hitachi

IBM HP7

100 100

Cutoff Frequency

• IBM HP8 St-9MW

150 150

200 200

Ft (GHz) Tektronix 70000B/C

250 250

300 300

Agilent Next Gen

350 350

 Lower noise operation in high frequency architectures

 High Ft, BS vias, high resistivity substrates enable flatter response to higher frequencies  Clear path to 300+ GHz Ft

Agilent Confidential 20

Using Frequency Interleaving to Achieve 30 GHz

ADC Down converter

Preamplifier ADC

Low frequency components from 0 - 16 GHz

ADC Preamplifier ADC

DSP Channel Combiner

Notice, that one down-converter is now in use and a triplexer. Requires three pre-amps, which is why it is only available on ONE channel

Triplexer

Attenuator

High frequency components from 16 – 30 GHz

Using Frequency Interleaving to Achieve 45 GHz High frequency components from 31 – 45 GHz

ADC Down converter

ADC

High frequency components from 16 – 30 GHz

ADC Down converter

Preamplifier ADC

Low frequency components from 0 - 16 GHz

ADC Preamplifier ADC

DSP Channel Combiner

Notice, that two down-converters are now in use and a triplexer. Requires three pre-amps, which is why it is only available on ONE channel

Triplexer

Attenuator

Preamplifier

Engineered for true analog bandwidth that delivers The highest measurement accuracy : industry’s lowest noise floor

Frequency Interleaving

DSP Boosting

At 20 GHz, the 90000 XSeries has less than ½ the noise floor of either Tektronix or LeCroy At 32 GHz, the 90000 XSeries has less noise than Tektronix or LeCroy have at 16 GHz! You get the additional nine GHz of analog bandwidth with no noise penalty compared to other oscilloscope vendors.

Infiniium 86100D DCA-X System Optical & Electrical Applications

• Storage & Communication R&D • Storage & Communication MFG • Computers & High-Speed Consumer Electronics R&D

The world’s most accurate oscilloscope • Modular platform providing four instruments in one: – Digital Communication Analyzer: de-facto industry standard – Wideband oscilloscope: DC to > 93 GHz coverage – Time Domain Reflectometer – Jitter Analyzer

Oscilloscopes Portfolio Overview Agilent Confidential October1, 9 2009 September 2010

Why buy the DCA-X Series? Deep insights – helps R&D to address root causes of issues • Accurate knowledge accelerates design cycles • Faster time-to-market = competitive advantage, lower investment cost

Great modularity – allows MFG to test large variety of products • Re-use of test equipment improves utilization rates, reduces CAPEX • > 12 years (4 generations) backward compatibility protects past investments

Superior usability – pleases novice and power users • Occasional users can complete tasks with less risk of accidental errors • Power users get throughput that save$ time when testing larger quantities

Oscilloscopes Portfolio Overview Agilent Confidential October1, 9 2009 September 2010

Suggest Documents