Agilent Technologies Oscilloscopes
March 2011
Agilent Oscilloscopes - Industry’s Largest Portfolio Infiniium 600MHz – 80GHz
DCA-X Series
90000 X-Series 90000 Series
Fastest Growing Scope Company Economy
InfiniiVision
20MHz – 200MHz
70MHz – 1GHz
Handheld
9000 Series
USB 7000 Series U2700 Series
U1600A Series
2000X Series
3000X Series
6000/6000L Series
September 1, 2010
Agilent 100 MHz / 200 MHz HH Scopes At A Glance Model
U1610A
U1620A
Bandwidth
100 MHz
200 MHz
Channel
2
2
Display
5.7” VGA TFT LCD color display (640 x 480 pixels)
Sampling rate
1 GSa/s (500 MSa/s for each channel)
2 GSa/s (1 GSa/s for each channel)
Recording length (Memory)
120 kpts / channel interleave (60 kpts for non-interleave channel)
2 Mpts / channel interleave (1 Mpts for non-interleave channel)
Meter Function Meter resolution
10,000 counts
Meter measurements
DCV, ACV, ACV+DCV, Diode, Continuity, Resistance, Capacitance, Temperature, Frequency User-ability
Local Language Graphic User Interface (GUI)
10 selectable languages: English, Francais, Deutsch, Italiano, Espanol, Portugues, Simplified Chinese, Traditional Chinese, Japanese, Korean
View mode
Indoor mode, Outdoor mode, Night vision Safety
Channel-to-channel isolation
Safety rating
CAT III 600 V
Ingress Protection
IP 41
Group/Presentation Title Month ##, 200X
World’s 1st HH Scope With VGA TFT LCD Display
5.7 inch VGA TFT LCD What it really means
How it benefits user?
VGA
4x more resolution
4x more details than QVGA
TFT LCD
A variant of liquid crystal display (LCD) that uses thin-film transistor (TFT) technology to improve image quality
Better image addressability and contrast to view waveform clearly Group/Presentation Title Month ##, 200X
Read Under All Lightning Conditions
Indoor mode
Outdoor mode
Night vision mode
Group/Presentation Title Month ##, 200X
See Signal Details Over Long Period Of Time 2 Mpts memory - for validation and debug:
Chasing down a problem View both problem effect and problem cause in a single acquisition
Characterizing the signal Maintain high signal resolution when zooming in, even after acquiring long periods of time
Page 6
Group/Presentation Title Month ##, 200X
InfiniiVision: 70 MHz-1GHz
InfiniiVision 70MHz – 1GHz
7000 Series
2000X Series
3000X Series
6000/6000L Series
September 1, 2010
Agilent InfiniiVision Series Engineered for Best Signal Visibility
Common Features: • MSO Models and Upgrades • Fast Waveform Update Rates • Deep & Responsive MegaZoom Memory
2000 X-Series
• High Resolution Display Intensity Gradation
3000 X-Series
• Hardware-based Serial Decode and Triggering
7000B Series
• Hardware-based Mask Testing • Segmented Memory
6000A Series Model
6000L Series
Unique Positioning
2000 X-Series 3000 X-Series
Lowest Price, WaveGen Fastest Update Rate, WaveGen 6000A Series Battery Option 6000L Series 1U High 7000B Series Highest Perf, Largest Display
* Half channel interleaved mode
• Search and Navigation
Bandwidth
Sample* Memory* Rate (max)
70MHz to 200MHz 100MHz to 500MHz 100MHz to 1GHz 100MHz to 1 GHz 100MHz to 1GHz
2 GSa/s 100 kpts 4 GSa/s 4 Mpts
50k /sec 1M /sec
2 or 4 2 or 4
8 optional 16 optional
4 GSa/s 4 GSa/s 4 GSa/s
100k /sec 100k /sec 100k /sec
2 or 4 2 or 4 2 or 4
16 optional 16 optional 16 optional
8 Mpts 8 Mpts 8 Mpts
Update Rate Scope Logic (max) Channels Channels
InfiniiVision 2000/3000 X-Series January 1, 2011 Page 8
Možnost vidět to, co na jiných osciloskopech zůstává skryto
8.5” WVGA obrazovka nabízí 2x větší zobrazovací plochu a 5x tolik pixelů Zpracování 1.000.000 průběhů / s
Paměť MegaZoom 4. generace
Agilent custom ASIC technology designed for market leading value.
Ne pouze osciloskop, ale 4 přístroje v jednom!
Osciloskop s nejrychlejším zpracováním signálu na trhu (1.000.000 stop / s) Logický analyzátor - 16 kanálů
Funkční a arbitrary generátor 20 MHz (DDS, 10 bit, 100 Msa/s, 5 kpts)
Protokolový analyzátor
Protokolový analyzátor Hardwarově akcelerované dekódování umožňuje protokolovou analýzu skutečně v reálném čase, korelovaně s časovým průběhem signálu, bez zpomalení činnosti osciloskopu. Možnost dekódování více sběrnic současně.
•
I2C/SPI
•
CAN/LIN
•
FlexRay
•
RS232/UART
•
I2S
•
MIL-STD 1553/ARINC 429
FlexRay trigger and decode
FlexRay eye diagram mask test
DSO InfiniiVisionX další měřicí aplikace • Digitální Voltmetr 3-místný digitální voltmetr používající osciloskopické vstupy
• Maskové Testy až 280.000 testů / s • Segmentovaná Paměť až 1.000 segmentů
• Analýza spínaných zdrojů • Advanced Math přídavné matematické funkce, filtry, trendy
• HDTV Video spouštění na highdefinition video signály
Infiniium: 600MHz - 80GHz DCA-X Series Up to 80 GHz
90000 X-Series
90000 Series
16 – 32 GHz
2.5 – 13 GHz
9000 Series 600 MHz – 4 GHz
September 1, 2010
Infiniium 9000 Series Key Applications
Embedded System Design Signal Integrity Compliance Verification Model
Analog Bandwidth
Max Sample Rate *)
Standard Memory *)
Analog Channels
DSO9064A
600 MHz
5 Gsa/s
20 Mpts
4
5 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
10 Gsa/s
20 Mpts
4
MSO9064A DSO9104A
1 GHz
MSO9104A DSO9254A
2.5 GHz
MSO9254A DSO9404A MSO9404A
4 GHz
Digital Channels
16
16
16
16
*) Sample Rate and Memory double in 2ch Mode
Engineered for broadest measurement capability September 1, 2010
Why buy the 9000 Series? The best 3 in 1 instrument – debug your design with a single tool • Industry-leading scope performance • High-performance logic analysis • Powerful, integrated protocol analysis
Broadest application selection (over 30) gives you an “Everything Analyzer” • • • •
Bus compliance, verification, and analysis InfiniiScan software triggers User-defined applications and functions Jitter analysis, equalization, de-embedding, and much more
Sized to fit your bench and budget • 15 inch display • Only 9 inches deep and only 26 pounds • Upgradeable memory, digital channels, bandwidth and apps
September 1, 2010
Why buy the 90000 Series? Superior signal integrity – shows the signal, not the scope • Lowest noise floor • Lowest trigger jitter • Agilent RF design expertise
Innovative probing – for your design • Industry-leading signal integrity – all the way to the probe tip • Flexible and comprehensive connection options
Designed for your application – today and tomorrow • Fully upgradeable, including bandwidth • Dozens of application packages expand your analysis
September 1, 2010
Infiniium 90000 X-Series Oscilloscopes Engineered for true analog bandwidth that delivers The highest real-time scope measurement accuracy Complete 30 GHz oscilloscope probing system The industry’s most comprehensive application-specific measurement software Bandwidth upgradeable for investment protection 6 New Scope Models DSO/DSA91604A DSO/DSA92004A DSO/DSA92504A DSO/DSA92804A DSO/DSA93204A Analog Bandwidth (2 ch) 16 GHz 20 GHz 25 GHz 28 GHz 32 GHz Max Sample Rate (2 ch / 4 ch) 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s 80/40 GSA/s Std Memory *) 20M 20M 20M 20M 20M Max Memory 2 Gpts 2 Gpts 2 Gpts 2 Gpts 2 Gpts Noise @ 50mV/div 1.34 mV 1.53 mV 1.77 mV 1.89 mV 2.08 mV Jitter Measurement Floor 150 fs rms 150 fs rms 150 fs rms 150 fs rms 150 fs rms *) DSA model: 50M Std Memory, EZJIT Plus, SDA
Why buy the 90000 X-Series? The industry’s highest real-time scope measurement accuracy
• Highest true analog bandwidth (32 GHz) • Lowest oscilloscope noise floor (2.04 mV at 50 mV/div, 32 GHz) • Lowest jitter measurement floor (150 fs)
Industry’s first 30 GHz oscilloscope probing system • InfiniiMax III high-frequency probes with automatic AC calibration (PrecisionProbe) • Fully-integrated probe amplifier s-parameter correction • The industry’s first bandwidth-upgradable probe amplifier
Industry’s most comprehensive application-specific measurement software • Broadest range of jitter, triggering, analysis and display tools • Pre-built compliance testing software based on the expertise of our engineers on the standards committees • Support for emerging technologies including FibreChannel, SAS 12G or MIPIMPhy
September 1, 2010
True Analog Bandwidth that Delivers
The Industry’s Highest Measurement Accuracy The Final Result: 1. Over 25% larger eye height and width measurements 2. Lower total jitter measurements 3. More detail is captured in the eye, that is buried in other oscilloscope noise floor
20 GHz versus 20 GHz at 10.4 Gbps j-BERT PRBS^7 signal, lowest setting of ISI added via the jBert
Innovative Chipset Designed in Agilent’s Proprietary Highspeed High-Voltage InP HBT Process Low noise and high measurement accuracy
25 25
InP SHBT & GaAs
Agilent’s Proprietary InP HBT Process Enabled by Unique HFTC GaAsSb Epi
20 20
BVceo (Volts)
UM
InP DHBT
15 15
Agilent HB2A Si & SiGe
TRW
Significant margin in speed and linearity Agilent & SFU Research
NTT
55
HRL IBM
00
Superior pulse distortion control, enhanced fidelity
Agilent HB2B
NGST GCS
10 10
2X usable voltage
0 0
50 50
Jazz Hitachi
IBM HP7
100 100
Cutoff Frequency
• IBM HP8 St-9MW
150 150
200 200
Ft (GHz) Tektronix 70000B/C
250 250
300 300
Agilent Next Gen
350 350
Lower noise operation in high frequency architectures
High Ft, BS vias, high resistivity substrates enable flatter response to higher frequencies Clear path to 300+ GHz Ft
Agilent Confidential 20
Using Frequency Interleaving to Achieve 30 GHz
ADC Down converter
Preamplifier ADC
Low frequency components from 0 - 16 GHz
ADC Preamplifier ADC
DSP Channel Combiner
Notice, that one down-converter is now in use and a triplexer. Requires three pre-amps, which is why it is only available on ONE channel
Triplexer
Attenuator
High frequency components from 16 – 30 GHz
Using Frequency Interleaving to Achieve 45 GHz High frequency components from 31 – 45 GHz
ADC Down converter
ADC
High frequency components from 16 – 30 GHz
ADC Down converter
Preamplifier ADC
Low frequency components from 0 - 16 GHz
ADC Preamplifier ADC
DSP Channel Combiner
Notice, that two down-converters are now in use and a triplexer. Requires three pre-amps, which is why it is only available on ONE channel
Triplexer
Attenuator
Preamplifier
Engineered for true analog bandwidth that delivers The highest measurement accuracy : industry’s lowest noise floor
Frequency Interleaving
DSP Boosting
At 20 GHz, the 90000 XSeries has less than ½ the noise floor of either Tektronix or LeCroy At 32 GHz, the 90000 XSeries has less noise than Tektronix or LeCroy have at 16 GHz! You get the additional nine GHz of analog bandwidth with no noise penalty compared to other oscilloscope vendors.
Infiniium 86100D DCA-X System Optical & Electrical Applications
• Storage & Communication R&D • Storage & Communication MFG • Computers & High-Speed Consumer Electronics R&D
The world’s most accurate oscilloscope • Modular platform providing four instruments in one: – Digital Communication Analyzer: de-facto industry standard – Wideband oscilloscope: DC to > 93 GHz coverage – Time Domain Reflectometer – Jitter Analyzer
Oscilloscopes Portfolio Overview Agilent Confidential October1, 9 2009 September 2010
Why buy the DCA-X Series? Deep insights – helps R&D to address root causes of issues • Accurate knowledge accelerates design cycles • Faster time-to-market = competitive advantage, lower investment cost
Great modularity – allows MFG to test large variety of products • Re-use of test equipment improves utilization rates, reduces CAPEX • > 12 years (4 generations) backward compatibility protects past investments
Superior usability – pleases novice and power users • Occasional users can complete tasks with less risk of accidental errors • Power users get throughput that save$ time when testing larger quantities
Oscilloscopes Portfolio Overview Agilent Confidential October1, 9 2009 September 2010