Advantages of the Variable Frequency Generator (VFG)© Presented By: •Juergen Schulz, Canadian Advanced Inc. Paper Authored By: •Andy Limanowka, Canadian Advanced Inc. •Dana Pettigrew, Nexen International Petroleum © Worldwide Patent Pending Advanced Thinking >>> Down to Earth Service >>>

What is a VFG VARIABLE FREQUENCY GENERATOR (VFG) • Power Generator that varies Frequency and Voltage output • Operates 30-70 Hz, 400-5000 Volts • For use with ESP’s & other Variable Torque Loads requiring variable speed • Eliminates Variable Speed Drive and Transformer • Developed by: Canadian Advanced Inc. • With Nexen International & Finning Canada (Caterpillar) Advanced Thinking >>> Down to Earth Service >>>

How the VFG works • Reduced Speed Start • Reduced Voltage Start • Control Module controls: – Voltage, Current & Hz (RPM) – Diesel or Natural Gas Engine with Governor – Motor Protection – SCADA/Communication

Advanced Thinking >>> Down to Earth Service >>>

Well ESP

Power Generator

Generator Control/ Motor Protection

Start-up traces (40Hz Ramp Start) 3508 CAT; 12000 BPD pump and 644HP/3480V/117A motor Ramp Start Nominal full load Volt 3480V@60Hz Nominal full load Amps 90A@60Hz 2sec for system stabilizations inrush current 2.4 x full load current 200

3000

180 2500 160

140

120

100

1500

80 1000 60

40 500 20

0

0 3

4

5

6

7

8

9

10

TIME [s] Gen Volts

Advanced Thinking >>> Down to Earth Service >>>

Gen Current

11

12

13

14

15

AMPS

VOLTS

2000

Advantages of VFG

• Lower Capital & Maintenance Cost • More Efficient System, less Diesel fuel • Smaller Engines required to Drive Large ESP’s • No Harmonics, spikes or mirroring • Increase Production • Easy to Use – Fully Integrated System • Touch Screen Operation

Advanced Thinking >>> Down to Earth Service >>>

VFG Advantages

• • • • •

Improved Run Times Voltage / Current Optimization Hard Starting Advancements Recoverable Asset (Compared to High Line) Smaller Foot Print-Offshore Applications

Advanced Thinking >>> Down to Earth Service >>>

System Comparison Typical Variable Speed Drive System Power Generator

Variable Speed Drive

Load Filter

Step-Up Transformer

ESP

Step-Up Transformer

ESP

Typical Switchboard System Power Line

Switch board

Variable Frequency Generator System (Less Equipment) Power Generator

Generator Control/ Motor Protection

Advanced Thinking >>> Down to Earth Service >>>

ESP

Lower Capital / Maintenance cost • Engine Matched to Full Load of ESP • Low frequency Soft Start-up – No Need to Oversize Engine – VFG = 2.5 X Nameplate Current – Switchboard = 6-8 X Nameplate Current • Eliminates VFD & Transformer Capital Cost • Eliminates VFD Maintenance Cost

Advanced Thinking >>> Down to Earth Service >>>

Capital cost comparison Capital Cost Comparison, 3512 CAT 900 ekW

VFD & Step-up Transformer

Engine & Generator Traditional VFD

Advanced Thinking >>> Down to Earth Service >>>

VFG Controller

Engine & Generator

VFG System

Maintenance cost comparison Maintance Cost Comparison, 3512 CAT 900 ekW

VFD & Step-up Transformer

VFG Controller

Engine & Generator

Engine & Generator

Traditional VFD

VFG

Advanced Thinking >>> Down to Earth Service >>>

Fuel cost comparison Fuel Cost Comparison, 3512 CAT 900 ekW

Traditional VFD Fuel Consumption

VFG Fuel Consumption

Traditional VFD

VFG

Advanced Thinking >>> Down to Earth Service >>>

Output Waveform VFD vs VFG

Typical VFD Output Waveform - Unfiltered

Typical VFG Output Waveform

Advanced Thinking >>> Down to Earth Service >>>

Improved Run Times

• • • •

Soft starts reduce shaft stress Cable runs cooler – longer life Motor runs cooler – longer life No voltage spikes – ideal sine wave w/o any filter

RESULTS: Longer ESP Electric and Mechanical System Life – Reduced Electrical Losses

Advanced Thinking >>> Down to Earth Service >>>

Increased Production (Heijah 49) • Improve Efficiency by 5-10% – Less Heat! • VFG eliminates Heat and Turns to Oil Production • Example for Maximum of 3508 CAT Diesel Generator, 562 Series CKC12000, 650 hp ESP

• • • •

Traditional VFD & Transformer

VFG System

Maximum Frequency = 58 Hz

Maximum Frequency = 63 Hz

Gross Fluid = 11,600 bbl/day

Gross Fluid = 12,400 bbl/day

Net Oil (90%WCT) =1160 bbl/day

Net Oil (90%WCT)=1240 bbl/day

Production increase of 80 bbl/day of oil At $ 65/bbl add’l revenue of $ 5.200 per day Increase of annual revenue of over $ 1,8 Mio. Return of initial CAPEX in less than 3 months

Advanced Thinking >>> Down to Earth Service >>>

Increased Production (Qataban 11) Q11 VFG TEST.sp7

Pump Performance (TDH @ Design) CLift 562 KC16000 / 86 Stgs / 57.0 Hz 6000

5000

TDH, ft

4000

3000

2000

1000

0

0

5000

10000

15000

20000

25000

Liquid + Gas Rate, Bbl/D Pump Curve , Case 1 Pump Curve , Case 2 Min-Max Optimum Rate

Well System Curve , Case 1, (Truncated) Well System Curve , Case 2, (Truncated)

Reg: Nexen Inc. - Nexen Inc.

•On a VSD at 114 Amps and 57.0 Hz, 18,250 bfpd RED SOLID LINE •On a VFG at 114 Amps and 59.0 Hz, 19,550 bfpd BLUE DASHED LINE •VFG measured benefit of an extra 1,300 bfpd for a 7.1% increase. Advanced Thinking >>> Down to Earth Service >>>

VFG Entire unit prepared for shipment

Advanced Thinking >>> Down to Earth Service >>>

VFG Control panel during testing

Advanced Thinking >>> Down to Earth Service >>>

VFG Canadian Nexen Yemen (Heijah 49)

Advanced Thinking >>> Down to Earth Service >>>

VFG Touch-pad controls

Advanced Thinking >>> Down to Earth Service >>>

VFG Touch-pad controls

Advanced Thinking >>> Down to Earth Service >>>

VFG Touch-pad controls

Advanced Thinking >>> Down to Earth Service >>>

When to use a VFG

• • • • • •

Every time a Generator is used on an ESP Temporary or Permanent Installation Portable Well Testing Areas of Power Quality Problems Weak or Insufficient Supply Power Other Applications – PCP, Beam Pump, Ships, Fans, etc.

Advanced Thinking >>> Down to Earth Service >>>

Questions

For more information or pricing contact: Juergen Schulz or Sid Degen CANADIAN ADVANCED INC. 5307-72A AVENUE EDMONTON, ALBERTA, T6B 2J1 PHONE: 780-469-0770 FAX: 780-450-4592 Advanced Thinking >>> Down to Earth Service >>>

Thank you for your attention