ABB general machinery drives ACS355 Replacement guide, Altivar 31

Low voltage AC drives ABB general machinery drives ACS355 Replacement guide, Altivar 31 FOR LIMITED DISTRIBUTION ONLY Using the replacement guide ...
Author: Junior Jackson
0 downloads 0 Views 370KB Size
Low voltage AC drives

ABB general machinery drives ACS355 Replacement guide, Altivar 31 FOR LIMITED DISTRIBUTION ONLY

Using the replacement guide

Important notice This replacement guide is intended for limited distribution to ABB’s technical partners and customers who are replacing the Altivar 31 drive with the ACS355 drive. ABB has prepared this document to aid sales associates, authorized channel partners and customers in the replacement. Every attempt has been made to ensure the accuracy of the information. All installation and electrical work should be carried out by a trained professional. ABB takes no responsibility for any damages or other liability whatsoever (including any consequential damages, even if ABB or an ABB representative had advised of the possibility of such damages) resulting from the use or selection of this document for any information, apparatus, method, process, or similar item disclosed in this document. Specification is subject to change without notice.

This guide will help you to replace Altivar 31 with ABB general machinery drives, ACS355. Follow the steps outlined in this guide to find the optimal replacement product and to speed up the replacement process. Step 1: sizing of the drive Compare power range, mounting methods and dimensions to select the correct ACS355 product against the competitor's product. Step 2: wiring and parameter set-up Compare electrical data and basic parameter range for optimal replacement.

Did you know that ACS355 drives come with integrated safe torque-off (STO) functionality?

2 ABB general machinery drives | Replacement guide

Contents Replacement guide

ACS355 and Altivar 31

4

Power range

4

Basic parameters

5

Dimensions

6

Electrical data

8

Replacement guide | ABB general machinery drives 3

Power range ACS355 and Altivar 31

0

ACS355 IP20 1-phase 200 to 240 V ATV31 IP21 1-phase 200 to 240 V

0.37

0.18

2.2 kW

2.2 kW

ACS355 Overload ratings − 1.5 x I2N for 1 minute every 10 minutes − At start 1.8 x I2N for 2 s ACS355 IP20 3-phase 200 to 480 V

0.37

ATV31 IP21 3-phase 200 to 480 V

0.18

ATV31 Overload ratings − 1,5 X nominal current − 180% of the nominal motor torque for 2 seconds 22 kW

15 kW

Mounting methods Wall (back)

Side-by-side

DIN-rail

Sideways

ACS355

Yes

Yes

Yes

Yes (R0-R2)

ATV31

Yes

Yes

Yes

-

Free space requirements ACS355

ATV31

50 mm

75 mm

R0-R4

75 mm

4 ABB general machinery drives | Replacement guide

50 mm

Basic parameters ACS355 and Altivar 31

Replacement guide for ACS355

ACS355

Altivar 31

Power range IP20 1-phase 100-120 V





1-phase 200-240 V

0.37-2.2

0.18-2.2

3-phase 200-240 V

0.37-11

0.18-15

3-phase 380-480 V

0.37-22

0.37-15

Back mounting

x

x

Side-by-side

x

x

DIN-rail

x

x

Sideways

x (R0-R2)



Above

75

50

Below

75

50

Language

9901



Selects an application macro

9902

CFG Source configuration

Selects the motor control mode

9904



Motor nominal voltage

9905

Mounting methods

Free space requirements

Basic parameters

UnS Nominal motor voltage given on the rating plate

Motor nominal current

9906

nCr Nominal motor current given on the rating plate

Motor nominal frequency

9907

FrS Nominal motor frequency given on the rating plate

Motor nominal speed

9908

nSP Nominal motor speed given on the rating plate

Motor nominal power

9909



Maximum for external reference 1

1105

HSP High speed

Value for constant speed 1

1202

Speed reference

Value for constant speed 2

1203

SP2 2nd preset speed

Value for constant speed 3

1204

SP3 3rd preset speed

Minimum value of the analog input

1301

1)

CrL3 Value for low speed (LSP) on input AI3

1)

Defines the event or condition that activates relay 1

1401

r2 Relay r2

Maximum speed

2002

HSP High speed

Maximum limit for the drive output frequency

2008

tFr Maximum output frequency

Motor stop method

2102

Stt Normal stop mode

Acceleration time from zero to maximum frequency for ramp pair 1

2202

ACC Acceleration ramp time

Deceleration time from maximum frequency to zero for ramp pair 1

2203

dEC Deceleration ramp time

Maximum speed

Replacement guide | ABB general machinery drives 5

Dimensions ACS355 and Altivar 31

H

H

D

D W

W

Dimensions 200 V

ACS355

Altivar 31

Altivar 31

ACS355

kW

1-phase

1-phase

Frame

Frame

hp

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

W

H

D

W

H

D

0.18

0.25

-

-

-

72

145

130

0.37

0.5

70

169

161

72

145

130

0.55

0.75

-

-

-

72

145

140

0.75

1

70

169

161

72

145

140

1.1

1.5

70

169

161

105

143

150

1.5

2

105

169

165

105

143

150

2.2

3

105

169

165

140

184

150

Dimensions 200 V

ACS355

Altivar 31

kW

3-phase

3-phase

hp

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

W

H

D

W

H

D

3 R0 4 R1 6 R2 7

Altivar 31

ACS355

Frame

Frame

0.18

0.25

-

-

-

72

145

120

0.37

0.5

70

169

161

72

145

120

0.55

0.75

70

169

161

72

145

130

0.75

1

70

169

161

72

145

130

1.1

1.5

70

169

161

105

143

130

1.5

2

70

169

161

105

143

130

2.2

3

105

169

165

105

143

150

6

3

4

105

169

165

140

184

150

7

4

5

105

169

165

140

184

150

5.5

7.5

169

169

169

180

232

170

7.5

10

260

181

169

180

232

170

11

15

260

181

169

245

330

190

15

20

-

-

-

245

330

190

6 ABB general machinery drives | Replacement guide

1 R0 2 R1 5

8

R2

R3 R4

9

Dimensions ACS355 and Altivar 31

H H

D

D W W

Dimensions 400 V

ACS355

Altivar 31

Altivar 31

ACS355

kW

3-phase

3-phase

Frame

Frame

6

R0

hp

(mm)

(mm)

(mm)

(mm)

(mm)

(mm)

W

H

D

W

H

D

0.37

0.5

70

169

161

105

143

150

0.55

0.75

70

169

161

105

143

150

0.75

1

70

169

161

105

143

150

1.1

1.5

70

169

161

105

143

150

1.5

2

70

169

161

105

143

150

2.2

3

70

169

161

140

184

150

3

4

70

169

161

140

184

150

4

5

70

169

161

140

184

150

5.5

7.5

169

169

169

180

232

170

7.5

10

169

169

169

180

232

170

11

15

169

169

169

245

330

190

15

20

260

181

169

245

330

190

18.5

25

260

181

169

22

30

260

181

169

R1

7

8

R3

9 R4

Replacement guide | ABB general machinery drives 7

Electrical data ACS355 and Altivar 31

ACS355

+24 V ACS355: X1 Ramp

Const

pair sel

Speed 1 Rev

Fwd /

Start / Stop

ACS355: X1

+24 V GND

Const

Fwd /

Start /

Speed 1

Rev

Stop

+24 V GND

DCOM

DCOM

DI1

DI1

DI2

DI2

DI3

DI3

DI4 DI5 Sinking DI configuration (NPN connected).

8 ABB general machinery drives | Replacement guide

DI4 0V

DI5

Sourcing DI configuration (PNP connected) with external power supply.

Electrical data ACS355 and Altivar 31

ATV31

AOC AOV 24 V AI2 LI6 AI3

LI4 LI3

COM

LI2

AI1

LI1

+ 10

0 ± 10 V

X - Y mA

LI5

Reference potentiometer

CLI R2C

PC / -

R2A

PB

R1B

(2)

Braking resistor (if used)

PA /+

R1C P0 R1A

(1) T/L3

W/T3

S/L2

V/T2

R/L1

U/T1

W1

V1

U1

M 3

˜

Replacement guide | ABB general machinery drives 9

PROFIBUS DP fieldbus adapter module for ACS355 drives

The PROFIBUS DP fieldbus adapter module FPBA-01 is an optional device for ACS355 drives, enabling connection of the drive as a slave on a PROFIBUS network. PLC configuration First, install the GDS file (DP-V0). The file is available from ABB’s website at Products & Services –> ABB product guide –> Drives –> Drive Options –> Fieldbus options –> FPBA-01 PROFIBUS DP Adapter GSD file (DP-V0): ABB0959.zip. Alternatively, the GDS file (DP-V0) can be downloaded from www.profibus.com. Mechanical and electrical installation 1. Insert the FPBA-01 module into its specified slot on the drive. 2. Tighten the screw. 3. Plug the fieldbus connector into the FPBA-01 module. Drive configuration 1. Power up the drive. 2. In most cases, a parameter needs to be adjusted to activate the communication. Please refer to the drive documentation for information on the communication settings. With an ACS355 drive, set parameter 9802 COMM PROT SEL to EXT FBA. 3. Parameter group 51 shows the status of the FPBA configuration parameters. − For basic functionality, set the required node address at parameter 5102 NODE ADDRESS and the communication profile at 5105 PROFILE. Finally, validate the settings with 5127 FBA PAR REFRESH. − For improved functionality, also check fieldbus type at 5101 FBA TYPE, baudrate at 5103 BAUDRATE and telegram type at 5104 TELEGRAM TYPE. Cyclic data handling Both data-consistent and non-consistent communication can be used with the FPBA-01 module. With data-consistent communication, the whole cyclic data frame is transmitted during a single program cycle. Some PLCs must be programmed to transmit data-consistent telegrams; for further details, see the ABB Drives PROFIBUS DP adapter module user manual. PLEASE NOTE! More information is available in ABB Drives PROFIBUS DP adapter module user’s manual. This is included with the ACS355 Replacement Package and is also available at www.abb.com (document no. 3AFE68573271).

10 ABB general machinery drives | Replacement guide

PROFIBUS master

ABB drive

Other slave device

Notes

Replacement guide | ABB general machinery drives 11

www.abb.com/drives www.abb.com/drivespartners

© Copyright 2010 ABB. All rights reserved. Specifications subject to change without notice.

3AUA0000074232 REV B EN 16.6.2010 #15050

Contact us