UR23/42/48 USB to Serial port Adapter Your Best Solution for PC-to-PLC Communication

Overview The UR23/42/48 USB-to-Serial port adapter is a low-cost high-performance single chip solution that provides bi-directional connectivity between any standard USB compliant host systems with another serial device. Unlike previous file transfer methods like serial cable, parallel cable and IrDA, the UR23/42/48 adapter has a more advanced bus protocol and operation system that offers much higher bandwidth ndwidth and easier user interface. The UR23/42/48 adapter can be embedded in the link cable. Both sides of the cable function as an upstream connector that could join a USB network such as the USB port of a PC or the downstream port of a USB hub. Through switching and protocol adjustment in the controller chip, any PC or USB hosts can communicate with other PLC or serial devices while adopting maximum speed for bulk-type data formats. In addition, data are allowed to flow in both directions simultaneously without compromising on performance. Both PC and PLC can control the device using standard serial command; the data flow is directed by a vendor-specific scheme.

Features •

Transfers data between USB interface and serial device



Full compliance with the Universal Serial Bus Specification Version 1.1



USB full-speed connection



Double data buffer supporting two-way data transfer



Low power consumption



Supports suspend and resume power management



USB drivers running under WinXP, Win2000, WinME and Win98



Bus powered from USB port



Suitable for mobile PC environment



On-chip USB transceiver



On-chip oscillator using one 12 MHz crystal



No glue logic needed and can be embedded in small space



File synchronization



Two LEDs Display the power and communicate status

View/Download PDF format

Serial Communication Port1 (COM1 9pin Male) COM 1 is a serial port that supports RS-232 operation. The pin assignments of the port are listed in the following table: Pin 1 2 3 4 5 6 7 8 9

Function RS-232 RXD/ RS-232 TXD; jumper selectable RS-232 TXD/ RS-232 RXD; jumper selectable Signal Ground RS-232 RTS/ RS-232 CTS; jumper selectable RS-232 CTS/ RS-232 RTS; jumper selectable

The UR23’s COM1 port supports two kinds of pin function as following:

Serial Communication Port2 (COM2 25pin Male) COM2 is a serial port that supports RS232C, RS-422, and RS-485 operation. The pin assignments of the port are listed in the following table: Pin 1 2 3 4 5 6 7 8 9 10 11 12 13

Function Chassis ground RS-232 TXD RS-232 RXD RS-232 RTS RS-232 CTS Function as DSR Signal ground Function as CD (no function) (no function) (no function) RS-422 CTS+ RS-422 CTS-

Pin 14 15 16 17 18 19 20 21 22 23 24 25

Function RS-422 TXD+ and RS-485 TXD/RXD+ RS-422 TXD- and RS-485 TXD/RXDRS-422 RXD+ RS-422 RXD(no function) (no function) Function as DTR (no function) Function as RI RS-422 RTS+ RS-422 RTS5V input jumper selectable

UR-23/42/48 Linking cable connection example: Siemens S7-200 UR23 COM2 RS485 25-pin: Cable defines as following UR23 COM2

SIEMENS S7-200 PPI Port

PLC RS485

25Pin Female

9Pin Male

TXD/RXD+ 14

3

DATA+

TXD/RXD- 15

8

DATA -

SG 7

5

SG

5V 25

Mitsubishi A1S PLC : UR23 COM2 RS422 25-pin: CPU port cable defines as following UR23 COM2

Mitsubishi CPU Port

PLC RS422

25Pin Female

AnS/AnA/AnU Series; FX2

25Pin Male

TXD+ 14

2

RDB

TXD- 15

15 RDA

RXD+ 16

3

RXD- 17

16 SDA

RTX+ 23

4

CTX+

CTX+ 12

5

RTX+

RTX- 24

17 CTX-

CTX- 13

18 RTX-

SG 7 5V 25

7

SDB

SG

25 5V 20 21

Mitsubishi FX2N PLC : UR23 COM2 RS422 25-pin: CPU port cable defines as following UR23 COM2

Mitsubishi CPU Port

PLC RS422

25Pin Female

FX2n/FX1n/FX0n Series

8 Pin Round

TXD+ 14

2

RXD+

TXD- 15

1

RXD-

RXD+ 16

7

TXD+

RXD- 17

4

TXD-

SG 7

3 SG

5V 25

5 5V

UR23/42/48 USB-Serial Adapter User Guide 1. Product Features 2. System Requirements 3. Driver Installation (WIN2000) 4. Setting Up the RS232 Serial Device 5. Uninstalling the Driver Program

Product Features •

USB Specification Rev. 1.1 compliant



Support the RS232 Serial interface



Over 1Mbps data transfer rate



Support remote wake-up and power management

System Requirements •

IBM PC 486DX4-100 MHz CPU or higher or compatible system



Available USB port



CD-ROM drive of the UR23/42/48 device

Driver Installation (WIN2000) Follow the steps below to install Window 2000 driver of USB-Serial cable: 1. Power on your computer and make sure that the USB port is enabled and working properly. 2. Plug in the USB-Serial cable into the USB port and run the Found New Hardware Wizard to assist you in setting up the new device. Click Next to continue.

3.

Insert the USB-Serial cable software driver into the CD-ROM drive and click Next to continue. For Windows 98, click Search for a suitable driver for my

device (recommends) and click to search driver from the CD-ROM drive D:\ur2348 (D: represents CD-ROM)

4. Windows will detect the driver and click Next to continue installation.

5.

Click Finish to continue and let Windows copy the needed files to your hard disk.

6. You can check the Device Manager and see the Cermate USB-to-Serial PLC cable (Com Port)

.

Setting Up the RS232 Serial Device Follow the steps below to connect your RS232 Serial Device (ie: Modem) to the USB port of your PC: 1. Turn off your Modem. Plug the DB 25 connector of the USB-Serial cable (COM2 of UR23) into your Modem. Turn on the Modem afterwards. 2. Turn on your computer and plug in the USB connector of the USB-Serial cable into the USB port. 3. If you have already installed a Modem device before, click Start, Settings, Modems. Open Modems Properties, select the Modem, click Properties. In General tab, please change the Port value to USB to Serial Port (COM3). 4.

After finishing these processes, you can use USB to Serial Bridge Cable to connect RS232 Serial 56K FAX Modem and execute the Dial-up function to connect Internet, and send the FAX with the FAX software(ie: Microsoft FAX) properly.

Uninstalling the Driver Program If you want to remove the USB-Serial cable driver program, you can uninstall it by following steps below:

1. Unplug the USB-Serial cable from your PC. 2. Run the D:\ur2348\DrvRemover.exe program from the software CD-ROM, then reboot the PC.

UR23/42/48 USB-Serial Adapter User’s Guide 1. Product Features 2. System Requirements 3. Driver Installation ( Win98&ME ) 4. Setting Up the RS232 Serial Device 5. Uninstalling the Driver Program

Product Features •

USB Specification Rev. 1.1 compliant



Support the RS232 Serial interface



Over 1Mbps data transferring rate



Support remote wake-up and power management

System Requirements •

IBM PC 486DX4-100 MHz CPU or higher or compatible system



Available USB port



CD-ROM drive



Windows 98 or Windows ME

Driver Installation (WIN98&ME) Follow the steps below to install Window 98 or Window ME driver of USB-Serial cable: 1. Power on your computer and make sure that the USB port is enabled and working properly. 2. Plug in the USB-Serial cable into the USB port and run the Add New Hardware Wizard to assist you in setting up the new device. Click Next to continue. 3. Insert the USB-Serial cable software driver into the CD-ROM drive and click Next to continue and click to search driver from the CD-ROM drive D:\ur2348 (D: represents CD-ROM) 4. Windows will detect the driver and shows the USB to Serial Cable. Click Next to continue installation.

5. Click Next to continue and let Windows copy the needed files to your hard disk. 6. When Windows finishes installing the software, click Finish. 7.

See the Device Manager to check the Cermate UR23 USB-to-Serial PLC Cable(COM Port).

Setting Up the RS232 Serial Device Follow the steps below to connect your RS232 Serial Device (ie: Modem) to the USB port of your PC: 1. Turn off your Modem. Plug the DB 25 connector of the USB-Serial cable (COM2 of UR23) into your Modem. Turn on the Modem afterwards. 2. Turn on your computer and plug in the USB connector of the USB-Serial cable into the USB port. 3. If you have already installed a Modem device before, click Start, Settings, Modems. Open Modems Properties, select the Modem, click Properties. In General tab, please change the Port value to USB to Serial Port (COM3). 4. After finishing these processes, you can use USB to Serial Bridge Cable to connect RS232 Serial 56K FAX Modem and execute the Dial-up function to connect Internet, and send the FAX with the FAX software(ie: Microsoft FAX) properly.

Uninstalling the Driver Program If you want to remove the USB-Serial cable driver program, you can uninstall it by following the steps below: 5. Unplug the USB-Serial cable from your PC.

6.

Run the D:\ur2348\DRemover98_2k.exe program from the software CD-ROM, then reboot the PC.