NEMA Devices

11/1 11/2

Heavy Duty Contactors 3 pole, Class 40



11

Duplex Heavy Duty Controllers

11/36 Class 83 Non- Combination

Single Phase - 2 pole, 4 Pole & Vaccum, Class 40

11/37 Class 84 Combination Disconnect, Fusible & Non - Fusible

11/3

Reversing Contactors, Class 43

11/38 Class 84 Combination Circuit Breaker



ESP200 Solid State Overload Relays



11/4

General

11/7

Class 48. ESP200 & 3RB20 selection

11/8

Class 958 & 958L Special application overload relays

11/9

Selection



11/10 Technical Data

Heavy Duty Starters with Solid State Overload

11/11 Overview

Class 14 - Motor Starters

11/15 Selection

Class 17 - Combination Starters



Pump Control Panels with Solid State Overload



Class 87 - Pump Panels

11/39 Standard Panel 11/40 Vaccum Starter Panel

Class 88 - Reduced Voltage Pump Panels

11/41 Auto Transformer & Part Winding (2 Step) 11/42 Wye Delta Class 88

Field Modification Kits

11/43 Pilot Devices 11/45 NEMA Accessories

Factory Modifications

11/17 Non - Fusible

11/49 ESP 200 Starter Accessories

11/19 Fusible





11/54 NEMA Starter and Contactors - AC Coils

Class 18 - Combination Starters

11/21 MCP Type

Class 22 - Reversing Starters

11/23 Selection

Replacement Parts

11/55 NEMA Starter and Contactors - DC Coils, Late Break Aux Contacts

Class 26 - Combination Reversing Starters

11/24 Non - Fusible 11/25 MCP Type

Class 30 - Two Speed Starters

11/26 Constant or Variable Torque 11/27 Constant Horsepower

Class 18 - Combination Two Speed Starters

11/28 Non - Fusible, Constant or Varible Torque 11/29 Non - Fusible, Constant Horsepower 11/30 MCP Type, Constant or Variable Torque 11/31 MCP Type, Constant Horsepower

Reduced Voltage Heavy Duty Starters with Solid State Overload



Class 36 & 37

11/32 Auto Transformer 11/33 2 Step Part Winding 11/34 Wye Delta, Closed Transition 11/35 Wye Delta, Open Transition

Siemens ICP · 2011

ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 1 Tuesday, September 20, 2011 8:45 AM

Heavy Duty Contactors

3 Phase, Class 40 Selection

Ordering Information

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.

60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600

Letter J F A D G L C H E

Open Type & Standard Width Enclosure, 3 Phase, 3 Pole Max Hp

Enclosure Open Type

NEMA 1 General Purpose

Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size

Catalog Number

1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 75 150 — —

40BP32A* 217. 40CP32A* 273. 40DP32A* 320. 40EP32A* 461. 40FP32A* 583. 40GP32A* 762. 40HP32A* 940. 40IP32A* 1880. 40JG32A* 2256. 40LP32A* 4920. 40MP32A* 13148. 40NH32A* 18600. 40PH32A* 29587.

1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450

2 5 10 15 25 30 50 75 100 200 400 600 900

2 5 10 15 25 30 50 75 100 200 400 600 900

9 18 27 40 45 60 90 115 135 270 540 810 1215

00 0 1 — 2 — 3 — 4 5 6 7 8

— — — 13⁄4 — 21⁄2 — 31⁄2 — — — — —

List Price $

NEMA 4/4X Stainless

NEMA 4X Fiberglass

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

Watertight, Dusttight Div1 and Div 2 Industrial Use Corrosion Resistant Class I Groups C & D Weatherproof Class II Groups E,F&G Bolted Enclosures Indoor/Outdoor Use

Catalog Number

List Price $

Catalog Number

List Catalog Price $ Number

40BP32B* 40CP32B* 40DP32B* 40EP32B* 40FP32B* 40GP32B* 40HP32B* 40IP32B* 40JG32B* 40LP32B* 40MP32B* 40NH32B* 40PH32B*

235. 292. 339. 480. 677. 903. 1128. 2275. 2652. 5643. 16618. 22364. 34815.

Use Size 0 40CP32W* 40DP32W* 40EP32W* 40FP32W* 40GP32W* 40HP32W* 40IP32W* 40JG32W* 40LP32E* 40MP32E* 40NH32E* 40PH32E*

— 630. 677. 818. 1354. 1721. 2087. 3911. 4289. 7712. 21320. 27066. 39222.

Use Size 0 40CP32F* 40DP32F* 40EP32F* 40FP32F* 40GP32F* 40HP32F* 40IP32F* 40JG32F* — — — —

NEMA 7 & 9 NEMA 3 & 4

NEMA 12 NEMA 3/3R

List Price $

Catalog Number

List Price $

Catalog Number

List Price $

— 700. 740. 900. 1480. 1890. 2300. 4700. 8483. — — — —

Use Size 0 40CP32H* 40DP32H* 40EP32H* 40FP32H* 40GP32H* 40HP32H* 40IP32H* 40JG32H* 40LP32H* — — —

— 1363. 1425. 1580. 2294. 2853. 3431. 5138. 5050. 10477. — — —

Use Size 0 40CP320* 40DP320* 40EP320* 40FP320* 40GP320* 40HP320* 40IP320* 40JG320* 40LP320* 40MP320* 40NH320* 40PH320*

— 405. 452. 593. 884. 1128. 1373. 3084. 3461. 7712. 19157. 24900. 29583.

Extra Wide Enclosure, 3 Phase, 3 Pole Max Hp

Enclosure

200 Volts

230 Volts

1 1⁄2 3 7 1⁄2 10 10 15 25 30 40

1 1⁄2 3 7 1⁄2 10 15 20 30 40 50

460 Volts

575 Volts

2 5 10 15 25 30 50 75 100

2 5 10 15 25 30 50 75 100

Contactor Amp NEMA Half Range Size Size

9 18 27 40 45 60 90 115 135

00 0 1 — 2 — 3 — 4

Dual voltage coils not available in size 5-8 starters. Enclosure is NEMA Type 4 (painted steel).

— — — 1 3/4 — 2 1/2 — 3 1/2 —

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

NEMA 7 & 9 NEMA 3 & 4

NEMA 12 NEMA 3/3R

Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G

Industrial Use Weatherproof Bolted Enclosures

Indoor/Outdoor Use

Catalog Number

40BP82B* 40CP82B* 40DP82B* 40EP82B* 40FP82B* 40GP82B* 40HP82B* 40IP82B* 40JG82B*

List Price $

509. 577. 624. 765. 923. 1130. 1476. 2492. 2868.

Catalog Number

Use Size 0 40CP82W* 40DP82W* 40EP82W* 40FP82W* 40GP82W* 40HP82W* 40IP82W* 40JG82W*

Only available S coil 24-60V DC F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC

List Price $ Catalog Number

— 1072. 1117. 1260. 2088. 2293. 4128. 5142. 5521.

Use Size 0 40CP82H* 40DP82H* 40EP82H* 40FP82H* 40GP82H* 40HP82H* 40IP82H* 40JG82H*

List Price $ Catalog Number List Price $

— 2312. 2365. 2518. 3233. 3792. 4102. 5809. 5660.

Standard Auxiliary Contacts

All FVNR Starters & Contactors

Size (3rd Character

Configuration

B Thru E

1N.O.

Internal

F Thru J

1N.O.

External

Internal / External

L Thru M

2N.O., 2N.C.

External

N Thru P

1N.O., 1N.C.

External

Lugs are not included

Siemens ICP · 2011

— 641. 687. 829. 1326. 1532. 2529. 3544. 3921.

Only available F coil100-250V AC 50/60Hz, or DC

Type

11/1

Use Size 0 40CP820* 40DP820* 40EP820* 40FP820* 40GP820* 40HP820* 40IP820* 40JG820*

ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 2 Tuesday, September 20, 2011 8:45 AM

Heavy Duty Contactors

Single Phase, 4 Pole & Vacuum, Class 40 Selection

1 Ordering Information

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.

60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600

Letter J F A D G L C H E

⁄3 1 2 3 3 5 7 1⁄3 — —

1 2 3 5 7 1⁄2 10 15 — —

9 18 27 35 45 60 90 115 135

00 0 1 1P 2 — 3 — 4

Open Type

NEMA 1

Standard Auxiliary Contacts

General Purposes Watertight, Dusttight

Half Size

Catalog No

Catalog No

— — — — — 21⁄2 — 31⁄2 —

40BP12A* 40CP12A* 40DP12A* 40EP12A* 40FP12A* 40GP12A* 40HP12A* 40IP12A* 40JG12A*

188. 245. 292. 376. 546. 705. 865. 1711. 2087.

40BP12B* 40CP12B* 40DP12B* 40EP12B* 40FP12B* 40GP12B* 40HP12B* 40IP12B* 40JG12B*

207. 264. 311. 295. 640. 846. 1053. 2106. 2483.

NEMA 4/4X Stainless

NEMA 4X Fiberglass

NEMA 7 & 9 NEMA 3 & 4

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

Div 1 and Div 2 Corrosion Resistant

Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Bolted Enclosure Indoor/Outdoor Use

Catalog No

Catalog No

Catalog No

Use Size 0 40CP12W* 40DP12W* 40EP12W* 40EP12W* 40GP12W* 40HP12W* 40IP12W* 40JG12W*

— 602. 650. 734. 1316. 1664. 2012. 3742. 4120.

Use Size 0 40CP12F* 40DP12F* 40EP12F* 40FP12F* 40GP12F* 40HP12F* 40IP12F* 40JG12F*

— 670. 720. 810. 1450. 1830. 2213. 4100. 4985.

Use Size 0 40CP12H* 40DP12H* 40EP12H* 40FP12H* 40GP12H* 40HP12H* 40IP12H* 40JG12H*

NEMA 12 NEMA 3/3R

Catalog No

— 1316. 1382. 1481 2242. 2593. 3347. 4954. 4881.

Use Size 0 40CP120* 40DP120* 40EP120* 40FP120* 40GP120* 40HP120* 40IP120* 40JG120*

— 376. 423. 508. 846. 1072. 1298. 2914. 3292.

Open Type & Standard Width Enclosure, 4 Pole Max Hp

⁄3 2 3 5

1 1⁄2 3 7 1⁄2 10

2 5 10 15

2 5 10 15

9 18 27 40

00 0 1 —

— — — 13⁄4

Open Type

NEMA 1

No Auxiliary Contacts Included

General Purpose

40BP22A* 40CP22A* 40DP22A* 40EP22A*

6 7 8 9 10

Enclosure

Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog No 1

4

Enclosure

Cont208/ actor 115 230 Amp NEMA Volts Volts Rating Size 1

3

5

Open Type & Standard Width Enclosure, Single Phase, 2 Pole Max Hp

2

Catalog No

245. 348. 395. 536.

40BP22B* 40CP22B* 40DP22B* 40EP22B*

NEMA 4/4X Stainless

NEMA 4X Fiberglass

NEMA 7 & 9 NEMA 3 & 4

NEMA 12 NEMA 3/3R

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

Watertight, Dusttight Corrosion Resistant

Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Bolted Enclosure Indoor/Outdoor Use

Industrial Use Weatherproof

Catalog No

264. 267. 414. 555.

Use Size 0 40CP22W* 40DP22W* 40EP22W*

Catalog No

— 705. 752. 893.

Catalog No

Use Size 0 40CP22F* 40DP22F* 40EP22F*

— 780. 830. 980.

Use Size 0 40CP22H* 40DP22H* 40EP22H*

11

Catalog No

— 1448. 1509. 1664.

Use Size 0 40CP220* 40DP220* 40EP220*

— 480. 527. 668.

12 13

Vacuum Contactors, 3 Phase, 3 Pole Max Hp 200V

230V

460V

575V

40 75 150

50 100 200

100 200 400

100 200 400

Contactor Amp Rating 225 300 500

NEMA Size 4 5 6

Open Type Catalog Number

List Price $

40JV32A* 40LV32A* 40MV32A*

14 15

Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating.

* You can order this quantity or a multiple thereof.

For other units and versions see A&D Mall.

16 Dual voltage coils not available for vacuum contactors. To order single phase contactor in an extra wide enclosure, order the enclosure kit and the open style contactor as separate items.

Coils D, F, or G will be wired for Incoming Voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters 1 Normally Open Auxiliary.

Siemens ICP · 2011

11/2

17

ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 3 Tuesday, September 20, 2011 8:45 AM

Heavy Duty Control

Reversing Contactor, Class 43 Selection

Ordering Information

Coil Table

Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.

60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600

Letter J F A D G L C H E

Open Type & Standard Width Enclosure, 3 Phase, 3 Pole Max Hp

Enclosure Open Type

Contactor 200 230 460 575 Amp NEMA Half Catalog Volts Volts Volts Volts Rating Size Size Number

11⁄2 3 7 1⁄2 10 10 15 25 30 40 75 100 — —

11⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450

2 5 10 15 25 30 50 75 100 200 400 600 900

2 5 10 15 25 30 50 75 100 200 400 600 900

9 18 27 40 45 60 90 115 135 270 540 810 1215

00 0 1 — 2 — 3 — 4 5 6 7 8

— — — 13⁄4 — 21⁄2 — 31⁄2 — — — — —

43BP32A* 43CP32A* 43DP32A* 43EP32A* 43FP32A* 43GP32A* 43HP32A* 43IP32A* 43JG32A* 43LP32A* 43MP32A* 43NH32A* 43PH32A*

NEMA 1

NEMA 4/4X Stainless

General Purpose

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dusttight NEMA 3 & 4 Corrosion Resistant

List Catalog Price $ Number

List Catalog Price $ Number

List Price $

Catalog Number

564. 677. 771. 1053. 1467. 1946. 2435. 5321. 6076. 12132. 28571. 40486. 8100.

602. 715. 828. 1110. 1617. 2153. 2698. 5810. 6565. 14963. 33273. 45189. —

— 1147. 1429. 1711. 2595. 3363. 4146. 8366. 9123. 18273. 37975. 49890. —

Use Size 0 — 43CP32F* 1261. 43DP32F* 1573. 43EP32F* 1898. 43FP32F* 2854. 43GP32F* 3701. 43HP32F* 4560. 43IP32F* 9202. 43JG32F* 10030. — — — — — — — —

43BP32B* 43CP32B* 43DP32B* 43EP32B* 43FP32B* 43GP32B* 43HP32B* 43IP32B* 43JG32B* 43LP32B* 43MP32B* 43NH32B* —

Use Size 0 43CP32W* 43DP32W* 43EP32W* 43FP32W* 43GP32W* 43HP32W* 43IP32W* 43JG32W* 43LP32E* 43MP32E* 43NH32E* —

NEMA 12 NEMA 3/3R

Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use

List Catalog Price $ Number

Use Size 0 43CP32H* 43DP32H* 43EP32H* 43FP32H* 43GP32H* 43HP32H* 43IP32H* 43JG32H* — — — —

List Catalog Price $ Number

List Price $

— 2331. 2575. 2859. 4296. 5480. 6898. 12537. 13291. — — — —

— 884. 997. 1279. 1899. 2604. 3319. 6768. 7526. 8878. 35068. 47728. —

Use Size 0 43CP320* 43DP320* 43EP320* 43FP320* 43GP320* 43HP320* 43IP320* 43JG320* 43LP320* 43MP320* 43NH320* —

Open Type & Standard Width Enclosure, Single Phase, 3 Wire, 2 Pole Max Hp

Enclosure Open Type

Cont208/ actor 115 230 Amp NEMA Volts Volts Rating Size Catalog No

1 1⁄3 1 2 3

1 2 3 5

9 18 27 35

00 0 1 1P

NEMA 1

NEMA 4/4X Stainless

NEMA 4X Fiberglass

General Purpose

Watertight, Dusttight Corrosion Resistant 304 Stainless Steel

Watertight, Dusttight Corrosion Resistant

List Price $ Catalog No List Price $ Catalog No

43BP12A* 43CP12A* 43DP12A* 43EP12A*

43BP12B* 43CP12B* 43DP12B* 43EP12B*

Use Size 0 43CP12W* 43DP12W* 43EP12W*

List Price $

Catalog No

List Price $



Use Size 0 43CP12F* 43DP12F* 43EP12F*

— 1241. 1552. 1862.

NEMA 7 & 9 NEMA 3 & 4

NEMA 12 NEMA 3/3R

Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use

Industrial Use Weatherproof

Catalog No

List Price $

Catalog No

— 2434. 2556. 2839.

Use Size 0 43CP120* 43DP120* 43EP120*

Use Size 0 43CP12H* 43DP12H* 43EP12H*

List Price $

— 709. 801. 1032.

Dual voltage coils not available in size 5–8 starters. Enclosure is NEMA Type 4 (painted steel). Coils D, F, or G will be wired for Incoming Voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. Only available S coil 24-60V DC F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC Only available F coil100-250V AC 50/60Hz, or DC

11/3

Siemens ICP · 2011

* You can order this quantity or a multiple thereof.

For other units and versions see A&D Mall.

ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 4 Tuesday, September 20, 2011 8:45 AM

Heavy Duty Control

Catalogue Numbering System for ESP200 SS O/L Relay General

1 2 Class

48 — Overload

No. of Poles

Size

A — Frame A B — Frame B

Model

T — ESP200

3 — 3 Phase 1 — Single Phase

Trip Curve

00— Class 5, 10, 20 or 30 Selectable

3

Current Range

A B C D E F G H J K L M N

— — — — — — — — — — — — —

0.25–1a Reset 0.75–3.4a 3–12a S — Selectable (Man/Auto) 5.5–22a 10–40 13–52 25–100 50–200 100–300 (3.33-10 current range with 300:5 CT and 1 loop with frame A1 (3-12A)-device) 133–400 (3.33-10 current range with 400:5 CT and 1 loop with frame A1 (3-12A)-device) 200–600 (3.33-10 current range with 600:5 CT and 1 loop with frame A1 (3-12A)-device) 250–750 (3.33-10 current range with 750:5 CT and 1 loop with frame A1 (3-12A)-device) 400–1200 (3.33-10.17 currant range with 1200:5 CT and 1 loop with frame A1 (3-12A)-device)

4 5 6 7 8

Trip Curve

Class Model Type

Amp Range

E — 10–40 G — 25–100 H — 50–200

9

No. of Poles

3 — 3 phase

10 11 Trip Curve

Class Model

D E F G H

— — — — —

5.5–22 10–40 13–52 25–100 50–200

12

Type

Amp Range

No. of Poles

13

3 — 3 phase

14 15 16 17

a Ranges available in Single or 3-phase.

Siemens ICP · 2011

11/4

ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 5 Tuesday, September 20, 2011 8:45 AM

Overload Relays

Solid State ESP200, Class 48, 958 and 958L Selection

Features

Benefits

6 Trip Classes - 5, 10, 20, or 30 Selectable by DIP-switches

6 Field changeable reduces time and inventory. Suitable for light, normal and heavy starting conditions

6 Phase Loss Protection - Trips in less than 3 Seconds

6 Protects motor burn out and minimizes motor heating up

6 Phase Unbalance - Trips based on Trip Class selected

6 Minimizes temperature rise of the motor on a asymmetrical three-phase-system

6 Ground Fault - Trips 60% of Motor Current

6 Provides optimum system protection of motors against high-resistance short-circuits or ground faults due to moisture, condensation, damage of insulation or any other reason

6 Trip Indicator - Visible

6 Save time, faster to identify overload Trip

6 Ambient Insensitive

6 Prevents nuisance tripping

6 No Heaters Required

6 Saves cost and eliminates time for installation of heaters

6 Self-Powered - No outside source required

6 Reduce cost for external power supply

6 FLA dial with wide Adjustment - 4:1 ratio

6 Provides wide range, reduces inventory

6 Self Protected in short circuit condition (when used with proper fuses or motor starter protector)

6 Unlike bimetal overloads, this eliminates replacement of the overload heaters after short circuit

6 Test Button - Tests Electronics

6 Tests the complete electronic functions including the trip mechanism. Increases up time

6 Thermal Memory

6 Prevents re-starting motor when it is still hot

6 Conformally coated circuit board

6 Resists against environmental conditions

6 1 NO and 1NC Contacts Standard. B600, R300

6 Makes it easier for user to wire local contacts

6 Operating Temperature: -25 °C - 65 °C

6 Wide operating range prevents nuisance tripping

6 Repeat Accuracy