NEMA Devices
11/1 11/2
Heavy Duty Contactors 3 pole, Class 40
11
Duplex Heavy Duty Controllers
11/36 Class 83 Non- Combination
Single Phase - 2 pole, 4 Pole & Vaccum, Class 40
11/37 Class 84 Combination Disconnect, Fusible & Non - Fusible
11/3
Reversing Contactors, Class 43
11/38 Class 84 Combination Circuit Breaker
ESP200 Solid State Overload Relays
11/4
General
11/7
Class 48. ESP200 & 3RB20 selection
11/8
Class 958 & 958L Special application overload relays
11/9
Selection
11/10 Technical Data
Heavy Duty Starters with Solid State Overload
11/11 Overview
Class 14 - Motor Starters
11/15 Selection
Class 17 - Combination Starters
Pump Control Panels with Solid State Overload
Class 87 - Pump Panels
11/39 Standard Panel 11/40 Vaccum Starter Panel
Class 88 - Reduced Voltage Pump Panels
11/41 Auto Transformer & Part Winding (2 Step) 11/42 Wye Delta Class 88
Field Modification Kits
11/43 Pilot Devices 11/45 NEMA Accessories
Factory Modifications
11/17 Non - Fusible
11/49 ESP 200 Starter Accessories
11/19 Fusible
11/54 NEMA Starter and Contactors - AC Coils
Class 18 - Combination Starters
11/21 MCP Type
Class 22 - Reversing Starters
11/23 Selection
Replacement Parts
11/55 NEMA Starter and Contactors - DC Coils, Late Break Aux Contacts
Class 26 - Combination Reversing Starters
11/24 Non - Fusible 11/25 MCP Type
Class 30 - Two Speed Starters
11/26 Constant or Variable Torque 11/27 Constant Horsepower
Class 18 - Combination Two Speed Starters
11/28 Non - Fusible, Constant or Varible Torque 11/29 Non - Fusible, Constant Horsepower 11/30 MCP Type, Constant or Variable Torque 11/31 MCP Type, Constant Horsepower
Reduced Voltage Heavy Duty Starters with Solid State Overload
Class 36 & 37
11/32 Auto Transformer 11/33 2 Step Part Winding 11/34 Wye Delta, Closed Transition 11/35 Wye Delta, Open Transition
Siemens ICP · 2011
ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 1 Tuesday, September 20, 2011 8:45 AM
Heavy Duty Contactors
3 Phase, Class 40 Selection
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.
60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600
Letter J F A D G L C H E
Open Type & Standard Width Enclosure, 3 Phase, 3 Pole Max Hp
Enclosure Open Type
NEMA 1 General Purpose
Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size
Catalog Number
1 1⁄2 3 7 1⁄2 10 10 15 25 30 40 75 150 — —
40BP32A* 217. 40CP32A* 273. 40DP32A* 320. 40EP32A* 461. 40FP32A* 583. 40GP32A* 762. 40HP32A* 940. 40IP32A* 1880. 40JG32A* 2256. 40LP32A* 4920. 40MP32A* 13148. 40NH32A* 18600. 40PH32A* 29587.
1 1⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450
2 5 10 15 25 30 50 75 100 200 400 600 900
2 5 10 15 25 30 50 75 100 200 400 600 900
9 18 27 40 45 60 90 115 135 270 540 810 1215
00 0 1 — 2 — 3 — 4 5 6 7 8
— — — 13⁄4 — 21⁄2 — 31⁄2 — — — — —
List Price $
NEMA 4/4X Stainless
NEMA 4X Fiberglass
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
Watertight, Dusttight Div1 and Div 2 Industrial Use Corrosion Resistant Class I Groups C & D Weatherproof Class II Groups E,F&G Bolted Enclosures Indoor/Outdoor Use
Catalog Number
List Price $
Catalog Number
List Catalog Price $ Number
40BP32B* 40CP32B* 40DP32B* 40EP32B* 40FP32B* 40GP32B* 40HP32B* 40IP32B* 40JG32B* 40LP32B* 40MP32B* 40NH32B* 40PH32B*
235. 292. 339. 480. 677. 903. 1128. 2275. 2652. 5643. 16618. 22364. 34815.
Use Size 0 40CP32W* 40DP32W* 40EP32W* 40FP32W* 40GP32W* 40HP32W* 40IP32W* 40JG32W* 40LP32E* 40MP32E* 40NH32E* 40PH32E*
— 630. 677. 818. 1354. 1721. 2087. 3911. 4289. 7712. 21320. 27066. 39222.
Use Size 0 40CP32F* 40DP32F* 40EP32F* 40FP32F* 40GP32F* 40HP32F* 40IP32F* 40JG32F* — — — —
NEMA 7 & 9 NEMA 3 & 4
NEMA 12 NEMA 3/3R
List Price $
Catalog Number
List Price $
Catalog Number
List Price $
— 700. 740. 900. 1480. 1890. 2300. 4700. 8483. — — — —
Use Size 0 40CP32H* 40DP32H* 40EP32H* 40FP32H* 40GP32H* 40HP32H* 40IP32H* 40JG32H* 40LP32H* — — —
— 1363. 1425. 1580. 2294. 2853. 3431. 5138. 5050. 10477. — — —
Use Size 0 40CP320* 40DP320* 40EP320* 40FP320* 40GP320* 40HP320* 40IP320* 40JG320* 40LP320* 40MP320* 40NH320* 40PH320*
— 405. 452. 593. 884. 1128. 1373. 3084. 3461. 7712. 19157. 24900. 29583.
Extra Wide Enclosure, 3 Phase, 3 Pole Max Hp
Enclosure
200 Volts
230 Volts
1 1⁄2 3 7 1⁄2 10 10 15 25 30 40
1 1⁄2 3 7 1⁄2 10 15 20 30 40 50
460 Volts
575 Volts
2 5 10 15 25 30 50 75 100
2 5 10 15 25 30 50 75 100
Contactor Amp NEMA Half Range Size Size
9 18 27 40 45 60 90 115 135
00 0 1 — 2 — 3 — 4
Dual voltage coils not available in size 5-8 starters. Enclosure is NEMA Type 4 (painted steel).
— — — 1 3/4 — 2 1/2 — 3 1/2 —
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
NEMA 7 & 9 NEMA 3 & 4
NEMA 12 NEMA 3/3R
Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G
Industrial Use Weatherproof Bolted Enclosures
Indoor/Outdoor Use
Catalog Number
40BP82B* 40CP82B* 40DP82B* 40EP82B* 40FP82B* 40GP82B* 40HP82B* 40IP82B* 40JG82B*
List Price $
509. 577. 624. 765. 923. 1130. 1476. 2492. 2868.
Catalog Number
Use Size 0 40CP82W* 40DP82W* 40EP82W* 40FP82W* 40GP82W* 40HP82W* 40IP82W* 40JG82W*
Only available S coil 24-60V DC F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC
List Price $ Catalog Number
— 1072. 1117. 1260. 2088. 2293. 4128. 5142. 5521.
Use Size 0 40CP82H* 40DP82H* 40EP82H* 40FP82H* 40GP82H* 40HP82H* 40IP82H* 40JG82H*
List Price $ Catalog Number List Price $
— 2312. 2365. 2518. 3233. 3792. 4102. 5809. 5660.
Standard Auxiliary Contacts
All FVNR Starters & Contactors
Size (3rd Character
Configuration
B Thru E
1N.O.
Internal
F Thru J
1N.O.
External
Internal / External
L Thru M
2N.O., 2N.C.
External
N Thru P
1N.O., 1N.C.
External
Lugs are not included
Siemens ICP · 2011
— 641. 687. 829. 1326. 1532. 2529. 3544. 3921.
Only available F coil100-250V AC 50/60Hz, or DC
Type
11/1
Use Size 0 40CP820* 40DP820* 40EP820* 40FP820* 40GP820* 40HP820* 40IP820* 40JG820*
ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 2 Tuesday, September 20, 2011 8:45 AM
Heavy Duty Contactors
Single Phase, 4 Pole & Vacuum, Class 40 Selection
1 Ordering Information
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.
60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600
Letter J F A D G L C H E
⁄3 1 2 3 3 5 7 1⁄3 — —
1 2 3 5 7 1⁄2 10 15 — —
9 18 27 35 45 60 90 115 135
00 0 1 1P 2 — 3 — 4
Open Type
NEMA 1
Standard Auxiliary Contacts
General Purposes Watertight, Dusttight
Half Size
Catalog No
Catalog No
— — — — — 21⁄2 — 31⁄2 —
40BP12A* 40CP12A* 40DP12A* 40EP12A* 40FP12A* 40GP12A* 40HP12A* 40IP12A* 40JG12A*
188. 245. 292. 376. 546. 705. 865. 1711. 2087.
40BP12B* 40CP12B* 40DP12B* 40EP12B* 40FP12B* 40GP12B* 40HP12B* 40IP12B* 40JG12B*
207. 264. 311. 295. 640. 846. 1053. 2106. 2483.
NEMA 4/4X Stainless
NEMA 4X Fiberglass
NEMA 7 & 9 NEMA 3 & 4
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
Div 1 and Div 2 Corrosion Resistant
Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Bolted Enclosure Indoor/Outdoor Use
Catalog No
Catalog No
Catalog No
Use Size 0 40CP12W* 40DP12W* 40EP12W* 40EP12W* 40GP12W* 40HP12W* 40IP12W* 40JG12W*
— 602. 650. 734. 1316. 1664. 2012. 3742. 4120.
Use Size 0 40CP12F* 40DP12F* 40EP12F* 40FP12F* 40GP12F* 40HP12F* 40IP12F* 40JG12F*
— 670. 720. 810. 1450. 1830. 2213. 4100. 4985.
Use Size 0 40CP12H* 40DP12H* 40EP12H* 40FP12H* 40GP12H* 40HP12H* 40IP12H* 40JG12H*
NEMA 12 NEMA 3/3R
Catalog No
— 1316. 1382. 1481 2242. 2593. 3347. 4954. 4881.
Use Size 0 40CP120* 40DP120* 40EP120* 40FP120* 40GP120* 40HP120* 40IP120* 40JG120*
— 376. 423. 508. 846. 1072. 1298. 2914. 3292.
Open Type & Standard Width Enclosure, 4 Pole Max Hp
⁄3 2 3 5
1 1⁄2 3 7 1⁄2 10
2 5 10 15
2 5 10 15
9 18 27 40
00 0 1 —
— — — 13⁄4
Open Type
NEMA 1
No Auxiliary Contacts Included
General Purpose
40BP22A* 40CP22A* 40DP22A* 40EP22A*
6 7 8 9 10
Enclosure
Contactor 200 230 460 575 Amp NEMA Half Volts Volts Volts Volts Rating Size Size Catalog No 1
4
Enclosure
Cont208/ actor 115 230 Amp NEMA Volts Volts Rating Size 1
3
5
Open Type & Standard Width Enclosure, Single Phase, 2 Pole Max Hp
2
Catalog No
245. 348. 395. 536.
40BP22B* 40CP22B* 40DP22B* 40EP22B*
NEMA 4/4X Stainless
NEMA 4X Fiberglass
NEMA 7 & 9 NEMA 3 & 4
NEMA 12 NEMA 3/3R
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
Watertight, Dusttight Corrosion Resistant
Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Bolted Enclosure Indoor/Outdoor Use
Industrial Use Weatherproof
Catalog No
264. 267. 414. 555.
Use Size 0 40CP22W* 40DP22W* 40EP22W*
Catalog No
— 705. 752. 893.
Catalog No
Use Size 0 40CP22F* 40DP22F* 40EP22F*
— 780. 830. 980.
Use Size 0 40CP22H* 40DP22H* 40EP22H*
11
Catalog No
— 1448. 1509. 1664.
Use Size 0 40CP220* 40DP220* 40EP220*
— 480. 527. 668.
12 13
Vacuum Contactors, 3 Phase, 3 Pole Max Hp 200V
230V
460V
575V
40 75 150
50 100 200
100 200 400
100 200 400
Contactor Amp Rating 225 300 500
NEMA Size 4 5 6
Open Type Catalog Number
List Price $
40JV32A* 40LV32A* 40MV32A*
14 15
Note: Hp’s shown above are based on the overload amp range for the FLA’s (per the National Electric Code) of typical industrial motors. All starter sizes carry one maximum Hp rating.
* You can order this quantity or a multiple thereof.
For other units and versions see A&D Mall.
16 Dual voltage coils not available for vacuum contactors. To order single phase contactor in an extra wide enclosure, order the enclosure kit and the open style contactor as separate items.
Coils D, F, or G will be wired for Incoming Voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters 1 Normally Open Auxiliary.
Siemens ICP · 2011
11/2
17
ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 3 Tuesday, September 20, 2011 8:45 AM
Heavy Duty Control
Reversing Contactor, Class 43 Selection
Ordering Information
Coil Table
Replace the (*) with a letter from the coil table. Dual voltage coils are wired on high voltage unless specified on order. Technical Data see www.sea.siemens.com/controls.
60Hz Voltage 24 Separate Control 120 Separate Control 110–120/220–240 200–208 220–240 277 220–240/440–480 440–480 575–600
Letter J F A D G L C H E
Open Type & Standard Width Enclosure, 3 Phase, 3 Pole Max Hp
Enclosure Open Type
Contactor 200 230 460 575 Amp NEMA Half Catalog Volts Volts Volts Volts Rating Size Size Number
11⁄2 3 7 1⁄2 10 10 15 25 30 40 75 100 — —
11⁄2 3 7 1⁄2 10 15 20 30 40 50 100 200 300 450
2 5 10 15 25 30 50 75 100 200 400 600 900
2 5 10 15 25 30 50 75 100 200 400 600 900
9 18 27 40 45 60 90 115 135 270 540 810 1215
00 0 1 — 2 — 3 — 4 5 6 7 8
— — — 13⁄4 — 21⁄2 — 31⁄2 — — — — —
43BP32A* 43CP32A* 43DP32A* 43EP32A* 43FP32A* 43GP32A* 43HP32A* 43IP32A* 43JG32A* 43LP32A* 43MP32A* 43NH32A* 43PH32A*
NEMA 1
NEMA 4/4X Stainless
General Purpose
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
NEMA 4X Fiberglass NEMA 7 & 9 Watertight, Dusttight NEMA 3 & 4 Corrosion Resistant
List Catalog Price $ Number
List Catalog Price $ Number
List Price $
Catalog Number
564. 677. 771. 1053. 1467. 1946. 2435. 5321. 6076. 12132. 28571. 40486. 8100.
602. 715. 828. 1110. 1617. 2153. 2698. 5810. 6565. 14963. 33273. 45189. —
— 1147. 1429. 1711. 2595. 3363. 4146. 8366. 9123. 18273. 37975. 49890. —
Use Size 0 — 43CP32F* 1261. 43DP32F* 1573. 43EP32F* 1898. 43FP32F* 2854. 43GP32F* 3701. 43HP32F* 4560. 43IP32F* 9202. 43JG32F* 10030. — — — — — — — —
43BP32B* 43CP32B* 43DP32B* 43EP32B* 43FP32B* 43GP32B* 43HP32B* 43IP32B* 43JG32B* 43LP32B* 43MP32B* 43NH32B* —
Use Size 0 43CP32W* 43DP32W* 43EP32W* 43FP32W* 43GP32W* 43HP32W* 43IP32W* 43JG32W* 43LP32E* 43MP32E* 43NH32E* —
NEMA 12 NEMA 3/3R
Div 1 and Div 2 Industrial Use Class I Groups C & D Weatherproof Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use
List Catalog Price $ Number
Use Size 0 43CP32H* 43DP32H* 43EP32H* 43FP32H* 43GP32H* 43HP32H* 43IP32H* 43JG32H* — — — —
List Catalog Price $ Number
List Price $
— 2331. 2575. 2859. 4296. 5480. 6898. 12537. 13291. — — — —
— 884. 997. 1279. 1899. 2604. 3319. 6768. 7526. 8878. 35068. 47728. —
Use Size 0 43CP320* 43DP320* 43EP320* 43FP320* 43GP320* 43HP320* 43IP320* 43JG320* 43LP320* 43MP320* 43NH320* —
Open Type & Standard Width Enclosure, Single Phase, 3 Wire, 2 Pole Max Hp
Enclosure Open Type
Cont208/ actor 115 230 Amp NEMA Volts Volts Rating Size Catalog No
1 1⁄3 1 2 3
1 2 3 5
9 18 27 35
00 0 1 1P
NEMA 1
NEMA 4/4X Stainless
NEMA 4X Fiberglass
General Purpose
Watertight, Dusttight Corrosion Resistant 304 Stainless Steel
Watertight, Dusttight Corrosion Resistant
List Price $ Catalog No List Price $ Catalog No
43BP12A* 43CP12A* 43DP12A* 43EP12A*
43BP12B* 43CP12B* 43DP12B* 43EP12B*
Use Size 0 43CP12W* 43DP12W* 43EP12W*
List Price $
Catalog No
List Price $
—
Use Size 0 43CP12F* 43DP12F* 43EP12F*
— 1241. 1552. 1862.
NEMA 7 & 9 NEMA 3 & 4
NEMA 12 NEMA 3/3R
Div 1 and Div 2 Class I Groups C & D Class II Groups E, F & G Class III Bolted Enclosures Indoor/Outdoor Use
Industrial Use Weatherproof
Catalog No
List Price $
Catalog No
— 2434. 2556. 2839.
Use Size 0 43CP120* 43DP120* 43EP120*
Use Size 0 43CP12H* 43DP12H* 43EP12H*
List Price $
— 709. 801. 1032.
Dual voltage coils not available in size 5–8 starters. Enclosure is NEMA Type 4 (painted steel). Coils D, F, or G will be wired for Incoming Voltage. J coil will be wired for separate source. Coils E, H, and L do not apply to single phase starters. Only available S coil 24-60V DC F coil 100-250V AC 50/60Hz, or DC H coil 150-500V AC 50/60Hz, or DC Only available F coil100-250V AC 50/60Hz, or DC
11/3
Siemens ICP · 2011
* You can order this quantity or a multiple thereof.
For other units and versions see A&D Mall.
ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 4 Tuesday, September 20, 2011 8:45 AM
Heavy Duty Control
Catalogue Numbering System for ESP200 SS O/L Relay General
1 2 Class
48 — Overload
No. of Poles
Size
A — Frame A B — Frame B
Model
T — ESP200
3 — 3 Phase 1 — Single Phase
Trip Curve
00— Class 5, 10, 20 or 30 Selectable
3
Current Range
A B C D E F G H J K L M N
— — — — — — — — — — — — —
0.25–1a Reset 0.75–3.4a 3–12a S — Selectable (Man/Auto) 5.5–22a 10–40 13–52 25–100 50–200 100–300 (3.33-10 current range with 300:5 CT and 1 loop with frame A1 (3-12A)-device) 133–400 (3.33-10 current range with 400:5 CT and 1 loop with frame A1 (3-12A)-device) 200–600 (3.33-10 current range with 600:5 CT and 1 loop with frame A1 (3-12A)-device) 250–750 (3.33-10 current range with 750:5 CT and 1 loop with frame A1 (3-12A)-device) 400–1200 (3.33-10.17 currant range with 1200:5 CT and 1 loop with frame A1 (3-12A)-device)
4 5 6 7 8
Trip Curve
Class Model Type
Amp Range
E — 10–40 G — 25–100 H — 50–200
9
No. of Poles
3 — 3 phase
10 11 Trip Curve
Class Model
D E F G H
— — — — —
5.5–22 10–40 13–52 25–100 50–200
12
Type
Amp Range
No. of Poles
13
3 — 3 phase
14 15 16 17
a Ranges available in Single or 3-phase.
Siemens ICP · 2011
11/4
ICP_2010_11_Pages 1 to 10_012810Edit_ab.fm Page 5 Tuesday, September 20, 2011 8:45 AM
Overload Relays
Solid State ESP200, Class 48, 958 and 958L Selection
Features
Benefits
6 Trip Classes - 5, 10, 20, or 30 Selectable by DIP-switches
6 Field changeable reduces time and inventory. Suitable for light, normal and heavy starting conditions
6 Phase Loss Protection - Trips in less than 3 Seconds
6 Protects motor burn out and minimizes motor heating up
6 Phase Unbalance - Trips based on Trip Class selected
6 Minimizes temperature rise of the motor on a asymmetrical three-phase-system
6 Ground Fault - Trips 60% of Motor Current
6 Provides optimum system protection of motors against high-resistance short-circuits or ground faults due to moisture, condensation, damage of insulation or any other reason
6 Trip Indicator - Visible
6 Save time, faster to identify overload Trip
6 Ambient Insensitive
6 Prevents nuisance tripping
6 No Heaters Required
6 Saves cost and eliminates time for installation of heaters
6 Self-Powered - No outside source required
6 Reduce cost for external power supply
6 FLA dial with wide Adjustment - 4:1 ratio
6 Provides wide range, reduces inventory
6 Self Protected in short circuit condition (when used with proper fuses or motor starter protector)
6 Unlike bimetal overloads, this eliminates replacement of the overload heaters after short circuit
6 Test Button - Tests Electronics
6 Tests the complete electronic functions including the trip mechanism. Increases up time
6 Thermal Memory
6 Prevents re-starting motor when it is still hot
6 Conformally coated circuit board
6 Resists against environmental conditions
6 1 NO and 1NC Contacts Standard. B600, R300
6 Makes it easier for user to wire local contacts
6 Operating Temperature: -25 °C - 65 °C
6 Wide operating range prevents nuisance tripping
6 Repeat Accuracy