266 GSH- Gauge Pressure

266 GSH- Gauge Pressure BASIC ORDERING INFORMATION model 266GSH Gauge Pressure Transmitter Select one character or set of characters from each categor...
Author: Alice Thornton
9 downloads 2 Views 95KB Size
266 GSH- Gauge Pressure BASIC ORDERING INFORMATION model 266GSH Gauge Pressure Transmitter Select one character or set of characters from each category and specify complete catalog number. Refer to additional ordering information and specify one or more codes for each transmitter if additional options are required. BASE MODEL - 1 st to 6t h characters

266GSH

X

X

X

X

X

Gauge Pressure Transmitter – BASE ACCURACY 0.06 % SENSOR - Span limits - 7th character 0.2 and 6 kPa

continued

2 and 60 m bar

0.8 and 24 inH2O

0.4 and 40 kPa

4 and 400 m bar

1.6 and 160 inH2O

F

2.5 and 250 kPa

25 and 2500 m bar 10 and 1000 inH2O

L

10 and 1000 kPa

0.1 and 10 bar

1.45 and 145 psi

D

30 and 3000 kPa

0.3 and 30 bar

4.35 and 435 psi

U

100 and 10000 kPa

1 and 100 bar

14.5 and 1450 psi

R

600 and 60000 kPa

6 and 600 bar

87 and 8700 psi

V

1522 and 15225 psi

Z

10500 and 105000 kPa 105 and 1050 bar

C

see next page

Di aphragm m aterial / Fill fluid (wetted parts) - 8th character Hastelloy C276™

Silicone oil

(Note 8)

NACE

K

Hastelloy C276™gol d-plated

Silicone oil

(Notes 2, 8)

NACE

G

Hastelloy C276™

Inert flui d - Galden

(Notes 1, 8)

NACE

F

Hastelloy C276™gol d-plated

Inert flui d - Galden

(Notes 1, 2, 8)

NACE

E

(Note 8)

NACE

Z

(Notes 9)

NACE

N

Hastelloy C276™

White oil (FDA)

Inconel 718

No filling

(for sensor Z ONLY)

X

Model 266GSH Gauge

BASIC ORDERING INFORMATION m odel 266GS H Gauge P ressure Transmitter

266GSHXX

X

X

X

X

Process connecti on (wetted parts) - 9t h character AISI 316 L ss

1/2 in – 14 NPT-f female

(Note 8)

NACE

B

AISI 316 L ss

1/2 in. – 14 NPT-f male

(Note 8)

NACE

T

AISI 316 L ss

DIN EN837-1 G 1/2 B

(Note 8)

NACE

P

Hastelloy C-276™

1/2 in. – 14 NPT-f female

(Note 8)

NACE

E

Hastelloy C-276™

1/2 in. – 14 NPT-f male

(Note 8)

NACE

K

Hastelloy C-276™

DIN EN837-1 G 1/2 B

(Note 8)

NACE

D

Inconel 718

F250C

(for sensor Z ONLY)

(Note 9)

NACE

6

Inconel 718

1/4 in. – 18 NPT-f female (for sensor Z ONLY)

(Note 9)

NACE

7

Gasket - 10th characters None

N

Housing m aterial and el ectrical connecti on - 11 character th

Aluminium alloy (barrel version)

1/2 in. – 14 NPT

Aluminium alloy (barrel version)

M20 x 1.5 (CM 20)

A

Aluminium alloy (barrel version)

Harting Han 8D connector

(general purpose only)

(Note 3)

E

Aluminium alloy (barrel version)

Fieldbus connector

(general purpose only)

(Note 3)

G

B

AISI 316 L ss (barrel version) (I2 or I3 required) 1/2 in. – 14 NPT

S

AISI 316 L ss (barrel version) (I2 or I3 required) M 20 x 1.5 (CM20)

T

AISI 316 L ss (barrel version) (I2 or I3 required) Fieldbus connector

(general purpose only)

(Note 3)

Z

Aluminium alloy (DIN version)

M20 x 1.5 (CM 20)

(not Ex d or XP)

Aluminium alloy (DIN version)

Harting Han 8D connector

(general purpose only)

(Note 3)

K

J

Aluminium alloy (DIN version)

Fieldbus connector

(general purpose only)

(Note 3)

W

Outp ut/Additi onal opti ons - 12t h character HART digital communicati on and 4 to 20 mA

No additi onal options

(Notes 4, 5)

HART digital communicati on and 4 to 20 mA

Opti ons requested by “Additi onal ordering code”

(Note 4)

H

PROFIBUS PA

No additi onal options

(Notes 4, 5)

PROFIBUS PA

Opti ons requested by “Additi onal ordering code”

(Note 5)

2

FOUNDATION Fieldbus

No additi onal options

(Notes 4, 5)

F

FOUNDATION Fieldbus

Opti ons requested by “Additi onal ordering code”

(Note 5)

HART and 4 to 20 mA Safety - certified to IEC 61508

No additi onal options

(Notes 4, 5)

T

HART and 4 to 20 mA Safety - certified to IEC 61508

Opti ons requested by “Additi onal ordering code”

(Note 4)

8

1 P

3

ADDITIONAL ORDERING INFORMATION for model 266GSH Add one or more 2-digit code(s) after the basic ordering information to select all required options XX XX XX Accuracy 0.04 % accuracy for applicable ranges

(Notes 10)

D2

Hazard ous area certificati ons ATEX Intrinsic Safety II 1 G and II 1/2 G Ex ia IIC T6; II 1 D Ex iaD 20 T 95 °C and II 1/2D Ex iaD 21 T 95 °C

(Notes 4, 5)

E1

ATEX Explosion Proof Group II Category 1/2 G Ex d IIC T6 and Group II Cat. 1/2 D Ex tD A21 IP67 T85 °C

(Notes 4, 5, 6)

E2

ATEX Type „N“ Group II Category 3 G Ex nL IIC T 6 and Group II Category 3 D Ex tD A22 IP67 T 85 °C

(Notes 4, 5)

E3

Com bi ned ATEX - Intrinsic Safety, Explosi on Proof and Type „N“

(Notes 4, 5, 6)

EW

Com bi ned ATEX - Intrinsic Safety and Expl osi on Proof

(Notes 4, 5, 6)

E7

Com bi ned ATEX, FM Approvals (USA) and FM Approvals (Canada)

(Notes 4, 5, 6)

EN E4

FM Approv als (Canada) approval

(Notes 4, 5, 6)

FM Approv als (USA) approval

(Notes 4, 5, 6)

E6

FM Approv als (USA and Canada) Intrinsic Safety

(Notes 4, 5)

EA

FM Approv als (USA and Canada) Explosi on Proof

(Notes 4, 5, 6)

FM Approv als (USA and Canada) Nonincendive

(Notes 4, 5)

IECEx Intrinsic Safety Ex ia IIC T6/T 5/T4; Ex iaD 20 T85 °C and Ex iaD 21 T85 °C;

(Notes 4, 5)

IECEx Explosi on Proof Ex d IIC T 6 and Ex tD A21 IP67 T 85 °C (Ta= -50 to +75 °C)

(Notes 4, 5, 6)

IECEx Type „N“ Ex nL IIC T 6/T5/T4

(Notes 4, 5)

Com bi ned IECEx - Intrinsic Safety, Explosi on Proof and Type „N“

(Notes 4, 5, 6)

EI

Com bi ned IECEx - Intrinsic Safety and Explosi on Proof

(Notes 4, 5, 6)

EH

NEPSI Intrinsic Safety Ex ia IIC T4∼T 6, DIP A20T A , T4∼T 6

(Notes 4, 5, 8)

EY EZ

EB EC E8 E9 ER

NEPSI Explosi on Proof Ex d IIC T 6, DIP A21T A , T6

(Notes 4, 5, 6, 8)

NEPSI Type „N“ Ex nL IIC T 4∼T6, DIP A22T A , TT 6

(Notes 4, 5, 8)

ES

Com bi ned NEPSI - Intrinsic Safety, Explosion Proof and Type „N“

(Notes 4, 5, 6, 8)

EQ

Com bi ned NEPSI - Intrinsic Safety and Expl osi on Proof

(Notes 4, 5, 6, 8)

EP

GOST (Russia) Ex ia

(Notes 2, 4, 5, 8)

W1

GOST (Russia) Ex d

(Notes 2, 4, 5, 6, 8)

W2

GOST (Kazakhstan) Ex ia

(Notes 2, 4, 5, 8)

W3

GOST (Kazakhstan) Ex d

(Notes 2, 4, 5, 6, 8)

W4

Inmetro (Brazil) Ex ia

(Notes 2, 4, 5, 8)

W5

Inmetro (Brazil) Ex d

(Notes 2, 4, 5, 6, 8)

W6

Inmetro (Brazil) Ex nL

(Notes 2, 4, 5, 8)

W7

Com bi ned Inmetro (Brazil) - Intrinsic Safety, Explosi on Proof and Type „N“

(Notes 2, 4, 5, 6, 8)

W8

GOST (Belarus) Ex ia

(Notes 2, 4, 5, 8)

WF

GOST (Belarus) Ex d

(Notes 2, 4, 5, 6, 8)

WG

_om bined GOST (Bela u ) - Int insi Safety and Explosi on P oof

(Notes 2, 4, 5, 6, 8

WH

Kosha (Korea) Intrinsic Safety Ex ia IIC T 6, IP67

(Notes 2, 4, 5, 8)

WM

Kosha (Korea) Expl osi on Proof Ex d IIC T 6, IP67

(Notes 2, 4, 5, 6, 8)

WN

Com bi ned Kosha (Korea) - Intrinsic Safety and Expl osi on Proof

(Notes 2, 4, 5, 6, 8)

WP

Other hazard ous area certificati ons

Integral LCD Digital LCD integral display

L1

TTG (Through-The-Glass) digital LCD controlled display

L5

2600T Series Pressure transmitters 266GSH, 266ASH | DS/266GSH/ASH-EN Rev. H 19

Model 266GSH Gauge

ADDITIONA L ORDERING INFOR MATION for m odel 266GS H

XX XX XX XX XX XX XX XX

Mounting bracket (shape and m aterial) For pipe/wall mounting - Carbon steel

(Not suitable for AISI housing)

For pipe/wall mounting - AISI 316 L ss

B6 B7

Surge Surge/Transient Protector

S2

Operating m anual (up to 2 different sel ections all owed) German (ONLY FOR HART and PROFIBUS VERSIONS)

M1

Italian (ONLY FOR HART VERSION)

M2

Spanish (ONLY FOR HART VERSION)

M3

French (ONLY FOR HART VERSION)

M4

English

M5

Chinese (ONLY FOR HART VERSION)

M6

Swedish (ONLY FOR HART VERSION)

M7

Polish (ONLY FOR HART VERSION)

M9

Portuguese (ONLY FOR HART VERSION)

MA

Turkish (ONLY FOR HART VERSION)

MT

Plates language German

T1

Italian

T2

Spanish

T3

French

T4

Additi onal tag pl ate Supplemental wired-on stainless steel plate

I1

Tag and certification stainless steel plates and laser printing of tag

I2

Tag, certification and supplemental wired-on stainless steel plates and laser printing of tag

I3

Configurati on Standard – Pressure = inH2O/ psi at 68 °F; Temperature = deg. F

N2

Standard – Pressure = inH2O/ psi at 39.2 °F; Temperature = deg. F

N3

Standard – Pressure = inH2O/ psi at 20 °C; Tem perature = deg. C

N4

Standard – Pressure = inH2O/ psi at 4 °C; Tem perature = deg. C

N5

Custom

N6

Preparati on proced ure Oxygen service cleaning (only available with inert fill and Viton gasket)

(Notes 8, 11)

P1

Pmax = 21 MPa for Galden or sensor overpressure, whichever il less; Tmax=60 °C/140 °F Certificates (up to 2 different selecti ons all owed) Inspecti on certificate EN 10204–3.1 of calibrati on (9-point)

C1

Inspecti on certificate EN 10204–3.1 of the cleanliness stage

C3

Inspecti on certificate EN 10204–3.1 of helium leakage test of the sensor module

C4

Inspecti on certificate EN 10204–3.1 of the pressure test

C5

Certificate of compliance with the order EN 10204–2.1 of instrument design

C6

Printed record of configured data of transmitter

CG

PMI test of wetted parts

CT

20 DS/266GSH /ASH-EN Rev. H | 2600T Series Pressure transmitters 266GSH, 266ASH

ADDITIONA L ORDERING INFORMATION FOR MODEL 266GSH

XX XX XX XX

Approval s GOST (Russia) without Ex

(NOT APPLICABLE WITH ANY HAZARDOUS AREA CERTIFICATION)

(Note 8)

Y1

GOST (Kazakhstan) without Ex

(NOT APPLICABLE WITH ANY HAZARDOUS AREA CERTIFICATION)

(Note 8)

Y2

GOST (Belarus) without Ex

(NOT APPLICABLE WITH ANY HAZARDOUS AREA CERTIFICATION)

Chinese pattern without Ex

(NOT APPLICABLE WITH ANY HAZARDOUS AREA CERTIFICATION)

(Note 8)

Y4

(Note 8)

Y5

DNV approval

(Note 8)

YA

Approval for Custody transfer (PENDING)

(Note 8)

YC

Materi al traceability Certificate of compliance with the order EN 10204–2.1 of process wetted parts

H1

Inspecti on certificate EN 10204–3.1 of process wetted parts

H3

Test report EN 10204–2.2 of pressure bearing and process wetted parts

H4

Connector Fieldbus 7/8 in. (Recommended for FOUNDATION Fieldbus) - (supplied loose without mati ng female pl ug)

(Notes 5, 7)

U1

Fieldbus M 12x1 (Recom mended for PROFIBUS PA) - (supplied loose wi thout mating female pl ug)

(Notes 5, 7)

U2

Harting Han 8D – straight entry - (supplied loose)

(Notes 4, 7)

U3

Harting Han 8D – angle entry - (supplied l oose)

(Notes 4, 7)

U4

Accessory Manifol d m ounting and pressure test (NOT AVAILABLE WITH OXYGEN SERVICE CLEANING - PREPARATION PROCEDURE CODE P1) Note Note Note Note Note Note Note Note Note Note Note

1: Suitable for o xyg en se rvice 2: Not available with Sen sor C, F 3: Select type in additio nal orderin g c ode 4: Not available with Housi ng code G, Z, W 5: Not available with Housi ng code E, K 6: Not available with Housi ng code J, K, W 7: Not available with Housi ng code, A, B, S, T, J 8: Not available with Sen sor code Z 9: Not available with Sen sor C, F, L, D, U, R, V 10: Not available with Sensor code C, F, V, Z 11: Not available with Process con necti on code P, D

Standard delivery items (can be differently specified by additional ordering code) – General purpose (no electrical certification) – No display, no mounting bracket, no surge protection – Multilanguage short-form operating instruction manual and labels in english (metal nameplate; self-adhesive certification and tag) – Configuration with kPa and deg. C units – No test, inspection or material traceability certificates