2

3/2 valve, normally open

Valve control, general symbol

3 1 4 2

5/2 valve, bi­stable

Valve control, roll

513

4

4 2

Valve control, spring

5/2 valve, mono­stable 513

Valve control, push button

4 2

5/3 valve, closed center 513

Valve control, pilot valve

4 2

5/3 valve, open center Valve control, direct acting solenoid

513 4 2

5/3 valve, pressurized center

Valve control, solenoid pilot valve

513 2

2/2 valve, normally closed, mono­stable, push button-controlled with spring return 3/2 valve, normally closed, mono­stable, pressure-controlled with spring return

4

Double 3/2 valve, normally closed/normally closed

1 2 12

5

Double 3/2 valve, normally open/normally open

5

2

4

3 1

Double 3/2 valve, normally closed/normally open

5

3

1

4

3 1

3/2 valve, normally closed

2

2

3

1 2

1

3

Solenoid valves, mechanical and manual valves

47

So l en oid va lves, mechanical a nd ma nua l va lves

Contents

Multiply Cv by 980 to get a Qn value in ln/min.

SY3000 & -5000 – overview

4

Cv 0.28

98

SV1000 – solenoid valve, cassette type

Cv 0.23

99

SV2000 – solenoid valve, tie rod type

Cv 0.48

101

SV2000 – solenoid valve, cassette type

Cv 0.56

102

SV3000 – solenoid valve, plug-in

Cv 0.93

104

SV4000 – solenoid valve, plug-in

Cv 1.6

106

SV1000, -2000 & -3000 – solenoid valve, body ported

Cv 0.28–0.93

108

VFN NAMUR – solenoid valve

Cv 1.4

109

Cv 0.8

110

Cv 1

111



57

SY3000 – solenoid valve, plug-in

Cv 0.44

58

SY5000 – solenoid valve, plug-in

Cv 0.88

61

VQD1000 – 4/2 solenoid valve

Cv 0.05

64

SYJ3000 – solenoid valve

Cv 0.12

65

SYJ5000 – solenoid valve

Cv 0.21

66

SYJ7000 – solenoid valve

Cv 0.74

68

SY3000 – solenoid valve

Cv 0.29

70

SY5000 – solenoid valve

Cv 0.9

72

SY7000 – solenoid valve

Cv 1.4

74

SY9000 – solenoid valve

Cv 2.5

76

VFS2000 – solenoid valve, plug-in

Cv 0.98–2.45

79

VSR8-4 & VSS8-4 – solenoid valve, plug-in, ISO 15407-2

SY3060 – valve manifold, cassette type

Cv 0.19

80

EVS7-6 & VQ7-6 – solenoid valve, ISO1

Cv 1.5

113

SY5060 – valve manifold, type

Cv 0.5

81

EVS7-8 & VQ7-8 – solenoid valve, ISO2

Cv 3.2

115

SY7060 – valve manifold, type

Cv 1

83

EVS7-10 – solenoid valve, ISO3

Cv 4.9

117

SJ2000 & -3000 – solenoid valve manifold, plug-in, cassette type Cv 0.08–0.12

84

Cv 1.5–4.9

118

VQC1000 solenoid valve, plug-in

Cv 0.25

86

VQC2000 – solenoid valve, plug-in

Cv 0.8

90

S070 – 3/2 miniature solenoid valve

Cv 0.006–0.021

119

VQC4000 – solenoid valve, plug-in

Cv 2

94

V114 & V111 – solenoid valve

Cv 0.008–0.016

120

VQ5000 – solenoid valve, plug-in

Cv 4.7

98

Cv 0.008

121

VF3000 & -5000 – solenoid valve

cassette

cassette



48

SV1000 – solenoid valve, tie rod type

EVS7-XSE647 – solenoid valve, ISO

3/2 solenoid valves

VV100 – 3/2 block mounted solenoid valve, cassette type

Subject to change

4/2, 5/2 and 5/3 solenoid valves

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SYJ300, -500 & -700 – 3/2 solenoid valve

Cv 0.1–0.5

123

LVM09/090 – 2/3 port direct operated solenoid valve for chemistry & analysis Cv 0.018 139

EVT307, VO307 & EVT317 – 3/2 solenoid valve

Cv 0.2–0.7

125

LVM10/100 – 2/3 port direct operated solenoid valve for chemistry & analysis Cv 0.03–0.04 139

Cv 0.2

126

VP – 3/2 solenoid valve, body ported

Cv 0.9–3.7

VG342 – solenoid valve, body ported, IP65

Cv 7.4–13.1

VKF300 – 3 port direct operated solenoid valve

LVM15/150 & -20/200 – 2/3 port direct operated solenoid valve for chemistry & analysis Cv 0.015–0.065

140

127

VDW10, -20 & -30 – 2/2 solenoid valve for water & air Cv 0.03–0.44

141

129

VDW200 & -300 – 3/2 solenoid valve for water & air

Cv 0.03–0.44

142

Cv 0.33–2.1

143

2/2 solenoid valves VQ20 & -30 – 2/2 solenoid valve

VCA – solenoid valve for air & inert gases Cv 0.39–0.78

130

Mechanical, manual valves VM, EVM, EVZM, VHK, VH & VR – mechanical, manual valves

131

Air operated valves

Cv 0.17–2.2

146

VXK21, -22 & -23 – 2 port direct operated solenoid valve with built-in strainer Cv 0.17–2.2 151 VXK with electronic timer and built-in strainer

Cv 0.61

152

SYJA, SYA & EVPA – 3/2, 5/2, 5/3 air operated valve

Cv 0.05–1

133

VGA342 – air operated 3/2 valve, body ported

VXD21 & -22 – pilot operated solenoid valve for water & other neutral media Cv 1.9–13

153

Cv 7.4–13.1

134

VXZ22 & -23 – zero differential pressure solenoid valve with brass body Cv 1.9–12

154

Proportional flow valves

VXZ22 & -23 – zero differential pressure solenoid valve with stainless steel body Cv 1.9–12 155

PVQ10 – proportional flow valve



135

PVQ30 – proportional flow valve

VXS22 & -23 – zero differential pressure solenoid valve for steam Cv 2.4–12

156



136

VNB & VND – 2/2 air operated valve for neutral media or steam Cv 1–48

157

SGC – 2/2 air operated valve for cutting fluids

158

Media valves LVC – 2/2 air operated chemical valve

Cv 0.35–6

137

LVA – 2/2 air operated chemical valve

Cv 0.07–6

137

Cv 0.35–3.3

138

LVQ – 2/2 air operated corrosion resistant chemical valve Cv 0.35–8

138

LVH – 2/2 manually operated chemical valve Subject to change

New VX21, -22 & -23 – normally closed, 2 port direct operated solenoid valve Cv 0.23–2.21 144 VX21, -22 & -23 – 2 port direct operated solenoid valve

Cv 0.05–3.2

4

Cv 1.25–18.3

49

So l en oid va lves, mechanical a nd ma nua l va lves

Directional control valves – solenoid valves

Metal seal

4

Rubber seal

Seal type, main valve

Ideal size for actuator control

Valve series

Flow characteristics A, BE (2 position/ mono­stable) Cv value3

VQD1

0.07

VQD1000 

VK1

0.12

VK3000 

SJ

0.08–0.12

SJ2000/3000 

SYJ

0.12–0.74

SYJ3000 

SX VQZ

Speed: 100

Applicable cylinder   Ø6

Ø10

Ø16

Ø20

Ø25

Ø32

Ø40

Ø50

Ø63

mm/s or lower

Ø80

Ø100

Ø125

SYJ5000 

SYJ7000 

0.18–0.82

SX3000 

SX5000 

  SX7000

0.32–1.2

VQZ1000 

VQZ2000

  VQZ3000

SV

0.28–1.6

SV1000 

SV2000 

VQ/ VQC

0.2–4.7

VQC1000 

VQC2000 

VQC4000 

SY

0.26–2.5

SY3000 

 SY3000 PLUG-IN

 SY7000

VF

0.13–3

VQ7

1.4–3.3

VFR

0.7–10.6

VP4

5.6–16.7

VZS

0.33–0.53

VZS2000 

VZS3000 

VQZ

0.17–0.74

VQZ1000 

VQZ2000 

VS4

1

VQ/ VQC

0.18–3.4

VQ7

1.1–3

VFS

0.4–9

VF1000 

 SY5000

 SV3000

Ø160

  SV4000 VQ5000 

  SY9000 (see example 1)

VF3000 

VF5000  VQ7-8 

VQ7-6  VFR2000 

Ø140

VFR3000 

 VFR4000

 VFR5000

VP4050 

  VQZ3000

VS410  VQC1000 

VQC2000 

VQ5000 

VQC4000  VQ7-6 

VFS1000 

 VFS2000

 VFS3000

VQ7-8  VFS4000 

 VFS5000

1.  Only available with single coil.   2.  Number in parentheses stands for power saving circuit.   3.  Multiply by 980 to get a Qn value in ln/min.

Conditions

Seal type



Rubber seal: Resistant to dust when the seals between the spool and sleeve are made ​​of rubber. Metal seal: Long life thanks to the air bearing between metal spool and steel sleeve.

Pressure: 0.5 MPa Tubing length: 1 m ■ Load: 50% ■ Stroke: 200 mm ■ Speed: 100 mm/s or lower ■

Cylinder size and speed

Subject to change

Example 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

50

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

5 port for pneumatics

Ø180

Ø200

Ø250

Ø300

Power consumption (W)

Connection size Push-in fitting (Ø) Applicable Threaded connection (G) tubing size (mm)

2

M5

4

4

M5, 1/8

4, 6

M3, M5

2, 4, 6

M3, M5, 1/8, 1/4

4, 6, 8

0.6

M5, 1/8, 1/4, 3/8

4, 6, 8, 10

0.4

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

0.6

1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

0.4

M5

3.2, 4, 6, 8, 10, 12

0.35 (0.1)2

M5, 1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

1.8

M5, 1/8, 1/4, 3/8, 1/2



1/4, 3/8, 1/2, 3/4

6, 8, 10

1.8

1/8, 1/4, 3/8, 1/2, 3/4, 1



12

3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2



1.8

1/8, 1/4

4, 6, 8

0.6 0.35 (0.1)

2

1 VFR6000  VP4070 

1

VFS6000 

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

5.5

1/8, 1/4, 3/8



1

M5, 1/4, 3/8

3.2, 4, 6, 8, 10, 12

1

1/4, 3/8, 1/2, 3/4

6, 8, 10, 12

1/8, 1/4, 3/8, 1/2, 3/4, 1



1.8

4

Power consumption Reduction of necessary power for the valve With power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.) Electrical circuit (with energy saving circuit) Diode

Time circuit

Red (+) LED

Coil

1

2

Black (–)

2: Holding current

Subject to change

1: Actuation power

51

So l en oid va lves, mechanical a nd ma nua l va lves

Directional control valves – solenoid valves

Metal seal

4

Rubber seal

Seal type, main valve

Ideal size for actuator control

Valve series

Flow ­characteristics A, BE (2 position/ mono­stable) Cv value3

VQD1

0.07

VQD1000 

VK1

0.12

VK3000 

SJ

0.08–0.12

SJ1000/2000 

SYJ

0.12–0.74

SYJ3000 

SX VQZ

Speed: 300

Applicable cylinder   Ø6

Ø10

Ø16

Ø20

Ø25

Ø32

Ø40

Ø50

Ø63

SYJ5000 

SYJ7000 

0.18–0.82

SX3000 

SX5000 

  SX7000

0.32–1.2

VQZ1000 

VQZ2000

  VQZ3000

SV

0.28–1.6

SV1000 

SV2000 

VQ/ VQC

0.2–4.7

VQC1000 

VQC2000 

VQC4000 

SY

0.26–2.5

SY3000 

 SY3000 PLUG-IN

 SY7000

VF

0.13–3

VQ7

1.4–3.3

VFR

0.7–10.6

VP4

5.6–16.7

VZS

0.33–0.53

VZS2000 

VZS3000 

VQZ

0.17–0.74

VQZ1000 

VQZ2000 

VS4

1

VQ/ VQC

0.18–3.4

VQ7

1.1–3

VFS

0.4–9

VF1000 

 SY5000

 SV3000

Ø80

Ø100

Ø125

Ø140

Ø160

  SV4000 VQ5000 

  SY9000 (see example 1)

VF3000 

VF5000  VQ7-6 

VFR2000 

mm/s or lower

VFR3000 

VQ7-8   VFR4000

VFR6000 

 VFR5000

VP4050 

  VQZ3000

VS410  VQC1000 

VQC2000 

VQC4000  VQ7-6 

VFS1000 

 VFS2000

 VFS3000

VQ5000  VQ7-8  VFS4000 

 VFS5000

VFS6000 

1.  Only available with single coil.   2.  Number in parentheses stands for power saving circuit.   3.  Multiply by 980 to get a Qn value in ln/min.

Conditions

Seal type



Rubber seal: Resistant to dust when the seals between the spool and sleeve are made ​​of rubber. Metal seal: Long life thanks to the air bearing between metal spool and steel sleeve.

Pressure: 0.5 MPa Tubing length: 1 m ■ Load: 50% ■ Stroke: 200 mm ■ Speed: 300 mm/s or lower ■

Cylinder size and speed

Subject to change

Example 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

52

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

5 port for pneumatics

Ø180

Ø200

Ø250

Ø300

Power ­consumption (W)

Connection size Push-in fitting (Ø) Applicable Threaded connection (G) tubing size (mm)

2

M5

4

4

M5, 1/8

4, 6

M3, M5

2, 4, 6

M3, M5, 1/8, 1/4

4, 6, 8

0.6

M5, 1/8, 1/4, 3/8

4, 6, 8, 10

0.4

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

0.6

1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

0.4

M5

3.2, 4, 6, 8, 10, 12

0.35 (0.1)2

M5, 1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

1.8

M5, 1/8, 1/4, 3/8, 1/2



1/4, 3/8, 1/2, 3/4

6, 8, 10

1.8

1/8, 1/4, 3/8, 1/2, 3/4, 1



12

3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2



1.8

1/8, 1/4

4, 6, 8

0.6 0.35 (0.1)

2

1

VP4070 

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

5.5

1

1/8, 1/4, 3/8



1

M5, 1/4, 3/8

3.2, 4, 6, 8, 10, 12

1

1/4, 3/8, 1/2, 3/4

6, 8, 10, 12

1/8, 1/4, 3/8, 1/2, 3/4, 1



1.8

4

Power consumption Reduction of necessary power for the valve With power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.) Electrical circuit (with energy saving circuit) Diode

Time circuit

Red (+) LED

Coil

1

2

Black (–)

2: Holding current

Subject to change

1: Actuation power

53

So l en oid va lves, mechanical a nd ma nua l va lves

Directional control valves – solenoid valves

Metal seal

4

Rubber seal

Seal type, main valve

Ideal size for actuator control

Valve series

Flow ­characteristics A, BE (2 position/ mono­stable) Cv value3

VQD1

0.07

  VQD1000

VK1

0.12

  VK3000

SJ

0.08–0.12

SYJ

0.12–0.74

SX VQZ

Speed: 500

Applicable cylinder   Ø6

Ø10

Ø16

Ø20

Ø25

Ø32

Ø40

Ø50

Ø63

mm/s or lower

Ø80

Ø100

Ø125

Ø140

Ø160

  SJ1000/2000 SYJ5000 

SYJ7000 

0.18–0.82

SX3000 

SX5000 

  SX7000

0.32–1.2

VQZ1000 

VQZ2000

  VQZ3000

SV

0.28–1.6

SV1000 

SV2000 

VQ/ VQC

0.2–4.7

VQC1000 

VQC2000 

VQC4000 

SY

0.26–2.5

SY3000 

 SY3000 PLUG-IN

 SY7000

VF

0.13–3

VQ7

1.4–3.3

VFR

0.7–10.6

VP4

5.6–16.7

VZS

0.33–0.53

VZS2000 

VZS3000 

VQZ

0.17–0.74

VQZ1000 

VQZ2000 

VS4

1

VQ/ VQC

0.18–3.4

VQ7

1.1–3

VFS

0.4–9

 SYJ3000

 SY5000

 SV3000

  SV4000

  SY9000 (see example 1)

VF3000 

 VF1000

VF5000  VQ7-6 

VFR2000 

VQ5000 

VFR3000 

VQ7-8   VFR4000

VFR6000 

 VFR5000

VP4070 

VP4050 

  VQZ3000

VS410  VQC1000 

VQC2000 

VQC4000  VQ7-6 

VFS1000 

 VFS2000

 VFS3000

VQ5000  VQ7-8  VFS4000 

 VFS5000

VFS6000 

1.  Only available with single coil.   2.  Number in parentheses stands for power saving circuit.   3.  Multiply by 980 to get a Qn value in ln/min.

Conditions

Seal type



Rubber seal: Resistant to dust when the seals between the spool and sleeve are made ​​of rubber. Metal seal: Long life thanks to the air bearing between metal spool and steel sleeve.

Pressure: 0.5 MPa Tubing length: 1 m ■ Load: 50% ■ Stroke: 200 mm ■ Speed: 500 mm/s or lower ■

Cylinder size and speed

Subject to change

Example 1: When using the valve series SY9000 (2500 ln/min) for driving Ø40 to Ø100 cylinders, they will have an average speed under the following conditions.

54

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

5 port for pneumatics

Ø180

Ø200

Ø250

Ø300

Power ­consumption (W)

Connection size Push-in fitting (Ø) Applicable Threaded connection (G) tubing size (mm)

2

M5

4

4

M5, 1/8

4, 6

M3, M5

2, 4, 6

M3, M5, 1/8, 1/4

4, 6, 8

0.6

M5, 1/8, 1/4, 3/8

4, 6, 8, 10

0.4

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

0.6

1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

0.4

M5

3.2, 4, 6, 8, 10, 12

0.35 (0.1)2

M5, 1/8, 1/4, 3/8, 1/2

4, 6, 8, 10, 12

1.8

M5, 1/8, 1/4, 3/8, 1/2



1/4, 3/8, 1/2, 3/4

6, 8, 10

1.8

1/8, 1/4, 3/8, 1/2, 3/4, 1



12

3/8, 1/2, 3/4, 1, 1 1/4, 1 1/2



1.8

1/8, 1/4

4, 6, 8

0.6 0.35 (0.1)

2

1

M5, 1/8, 1/4, 3/8

3.2, 4, 6, 8, 10

5.5

1

1/8, 1/4, 3/8



1

M5, 1/4, 3/8

3.2, 4, 6, 8, 10, 12

1

1/4, 3/8, 1/2, 3/4

6, 8, 10, 12

1/8, 1/4, 3/8, 1/2, 3/4, 1



1.8

4

Power consumption Reduction of necessary power for the valve With power saving circuit: The power consumption is reduced to one quarter of the standard product power consumption. (The effect occurs when the on time is greater than 62 ms and operated at rated voltage of 24 VDC.) Electrical circuit (with energy saving circuit) Diode

Time circuit

Red (+) LED

Coil

1

2

Black (–)

2: Holding current

Subject to change

1: Actuation power

55

So l en oid va lves, mechanical a nd ma nua l va lves

SMC’s metal seal valves Valves in high-frequency use often suffer from wear on the seals. SMC’s metal seal valves resist such wear and have superior life time.

4

A

valve spool change position inside the valve when it is affected manually, with spring force, or when power is applied to the coil. The spool position determines which ports are pressurised and exhausted. Many valves have a so called rubber seal, which can be compared to a rubber O-ring. This type of seal works very well and is found in many of SMC’s valves. In some applications, for example high-frequency applications, rubber seal can wear out, and the valves need to be replaced regularly. SMC offer an optional metal seal for these applications. This option extends the life time of the valve and your application. A metal seal spool moves in a fixed sleeve, which in turn is rubber sealed against the valve body. The fit between spool and sleeve is very precise. ■

■ ■ ■ ■ ■

At least 200 million cycles life time. There are documented cases where more than 1 billion cycles have been achieved. Less sensitive to impurities than conventional rubber seal valves. Friction free. Air gap between spool and sleeve. Highest precision, surface finish, and small gap (1 µm). Minimum leakage (slightly more than rubber seal valve).

Valve series available with metal seal: EVS, SQ, SY, VQ1000/2000/4000, VQ7, VQC and VSS.

Subject to change

Detail of the metal spool inside its sleeve.

56

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY3000 & -5000 – overview ■  SMC’s new SY3000 and SY5000 series is extremely flexible and versatile. ■  The high flow rate version enables you in many cases to use a smaller valve than usually. ■  See below for an overview of some series with unique advantages.

Cable interface

4 D-sub/flat cable

L connection

Circular multipole

Terminal box

Fieldbus interface

EX250

EX260

EX500

EX600

Flexibility

Function modules in sandwich format

Mix SY3000 and SY5000 on the same manifold

Easy to change port mode

Subject to change

Also available in hygienic design. Contact SMC for more information.

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

57

So l en oid va lves, mechanical a nd ma nua l va lves

SY3000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working ­pressure Operating temperature Voltage/power

4

Flow Enclosure

Air (dry) 5 µm 0.7 MPa (7 bar); high pressure type: 1 MPa (10 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar) –10 to 50 °C Standard: 24 VDC ±10% (12 VDC on ­request)/0.4 W (energy saving 0.1 W) 470 ln/min IP40/IP67 depending on choice of electrical connection

■ Unmatched flexibility and easy configuration because of new internal ­ connector technology and the ability to mix different sizes in the same manifold

Valve – plug-in, 24 VDC Part number SY3100-5U1 SY3100R-5U1 SY3101K-5U1 SY3101R-5U1 SY3200-5U1 SY3200R-5U1 SY3201K-5U1 SY3201R-5U1 SY3300-5U1 SY3400-5U1 SY3500-5U1 SY3301K-5U1 SY3401K-5U1 SY3501K-5U1 SY3A00-5U1 SY3B00-5U1 SY3C00-5U1

Type Weight 74 g 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal, 74 g external pilot 76 g 5/2 mono­stable, metal seal, high pressure 76 g 5/2 mono­stable, metal seal, external pilot 83 g 5/2 bi­stable, rubber seal 83 g 5/2 bi­stable, rubber seal, external pilot 86 g 5/2 bi­stable, metal seal, high pressure 86 g 5/2 bi­stable, metal seal, external pilot 87 g 5/3 closed center, rubber seal 87 g 5/3 exhausted center, rubber seal 87 g 5/3 pressurized center, rubber seal 90 g 5/3 closed center, metal seal, high pressure 90 g 5/3 exhausted center, metal seal, high press. 90 g 5/3 pressurized center, metal seal, high press. 83 g Double 3/2 NC/NC, rubber seal 83 g Double 3/2 NO/NO, rubber seal 83 g Double 3/2 NC/NO, rubber seal

Valve, plug-in

All versions available with external pilot supply. Contact SMC for delivery times.

Valve manifold, D-sub

Valve manifold for fieldbus – circular and L connection, Ø6 mm, add valves and electrical connector Part number SS5Y3-10S0-02D-C6 SS5Y3-10S0-04D-C6 SS5Y3-10S0-06B-C6 SS5Y3-10S0-08B-C6 SS5Y3-10S0-10B-C6 SS5Y3-10S0-12B-C6

Valve stations  2  4  6  8 10 12

Type Side ported Side ported Side ported Side ported Side ported Side ported

Valve manifold for D-sub connection – Ø6 mm, add valves and D-sub cable Part number SS5Y3-10F1-02D-C6 SS5Y3-10F1-04D-C6 SS5Y3-10F1-06B-C6 SS5Y3-10F1-08B-C6 SS5Y3-10F1-10B-C6 SS5Y3-10F1-12B-C6

58

Valve stations  2  4  6  8 10 12

■  = Delivery Ex-Stock  

Type Side ported Side ported Side ported Side ported Side ported Side ported

Sub plate, side ported

Sub plate, bottom ported

Metal sub plate for D-sub connection – Ø6 mm, add valves and D-sub cable Part number SS5Y3-50F1-04D-C6F SS5Y3-50F1-06B-C6F SS5Y3-50F1-08B-C6F SS5Y3-50F1-10B-C6F SS5Y3-50F1-12B-C6F SS5Y3-51F1-04D-C6F SS5Y3-51F1-06D-C6F SS5Y3-51F1-08D-C6F SS5Y3-51F1-10D-C6F SS5Y3-51F1-12D-C6F

Valve stations  4  6  8 10 12  4  6  8 10 12

Type Side ported Side ported Side ported Side ported Side ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Valve manifold, fieldbus

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY3000 – solenoid valve, plug-in Replacement & extension parts

Manifold bottom plate

End plate D-side, fieldbus

Manifold bottom plate – side ported Part number SY30M-2-1SA-C4 SY30M-2-1SA-C6 SY30M-2-1DA-C4 SY30M-2-1DA-C6

Type Single solenoid, Ø4 mm Single solenoid, Ø6 mm Double solenoid, Ø4 mm Double solenoid, Ø6 mm

End plate D-side for fieldbus – circular

and L connection, with supply and exhaust, side ported, Ø8 mm Part number SY30M-1-1A-C8 SY30M-1-1AS-C8 SY30M-1-1AR-C8

Type — Built-in silencer External pilot

Individual P-supply

Individual exhaust

Individual P-supply – for individual valve Part number SY30M-38-1A-C6

Type Ø6 mm

Individual exhaust – for individual valve Type Ø6 mm

End plate U-side

End plate D-side for D-sub connection – with supply and exhaust, side ported, Ø8 mm Part number SY30M-1-11A1-C8 SY30M-1-11AS1-C8 SY30M-1-11AR1-C8

Type — Built-in silencer External pilot

4

End plate U-side – with supply and exhaust, side ported, Ø8 mm Part number SY30M-3-1A-C8 SY30M-3-1AS-C8 SY30M-3-1AR-C8

Blanking plate

Type — Built-in silencer External pilot

DIN rail mount

Blanking plate – for unused valve stations Part number SY30M-26-1A SY30M-26-2A

Type For valve manifold For metal sub plate

DIN rail mount – for manifold, 1 mount per pack Part number SY30M-15-1A

Subject to change

Part number SY30M-39-1A-C6

End plate D-side, D-sub

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

59

So l en oid va lves, mechanical a nd ma nua l va lves

SY3000 – solenoid valve, plug-in Replacement & extension parts

4

P-shut-off

Check valve

P-shut-off – for individual valve

Double check module

Sealing disc

Double check module

– maintains correct position during long stops

Part number SY30M-50-1A

Part number SY30M-60-1A

Check valve – for exhaust channels

Sealing disc

Part number SY30M-24-1A

Part number SY30M-40-1A SY30M-40-2A

Type For P-supply (2 different pressures in manifold) For exhaust (2 different exhausts in manifold)

Electrical connections L connector cable – 34 wire Part number Type SY30M-14-4A-1-2 Connector with 1,5 m cable SY30M-14-4A-1-3 Connector with 3 m cable SY30M-14-4A-1-4 Connector with 5 m cable SY30M-14-4A-1-6 Connector with 10 m cable L connector cable – 17 wire

L connector cable

Part number Type SY30M-14-4A-2-3 Connector with 3 m cable L connector cable – 9 wire Part number Type SY30M-14-4A-3-3 Connector with 3 m cable Circular connector – 26-pin (IP67) Part number SY30M-14-5A AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

Type Circular connector Connector only Connector with 1,5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable D-sub cable with connector – 25-pin, in accordance with MIL-norm (0,3 mm2)

Circular connector

Circular connector, connector only

Circular connector, connector with cable

D-sub cable with connector

Part number VVQC1000-T0-1

Type 20 connections (IP67)

Fieldbus – all SI-units can be used with manifolds for fieldbus, see chapter 5 For other versions, contact SMC.

60

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Part number Type VVZS3000-21A-2* Connector with 3 m cable VVZS3000-21A-3* Connector with 5 m cable VVZS3000-21A-4* Connector with 8 m cable Terminal box – suitable for same manifolds as fieldbus connection

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY5000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working ­pressure Operating temperature Voltage/power Flow Enclosure

Air (dry) 5 µm 0.7 MPa (7 bar); high pressure type: 1 MPa (10 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar) –10 to 50 °C Standard: 24 VDC ±10% (12 VDC on ­request)/0.4 W (energy saving 0.1 W) 1060 ln/min IP40/IP67 depending on choice of electrical connection

4

■ Unmatched flexibility and easy configuration because of new internal ­ connector technology and the ability to mix different sizes in the same manifold

Valve – plug-in, 24 VDC Part number SY5100-5U1 SY5100R-5U1 SY5101K-5U1 SY5101R-5U1 SY5200-5U1 SY5200R-5U1 SY5201K-5U1 SY5201R-5U1 SY5300-5U1 SY5400-5U1 SY5500-5U1 SY5301K-5U1 SY5401K-5U1 SY5501K-5U1 SY5A00-5U1 SY5B00-5U1 SY5C00-5U1

Type Weight   82 g 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal,   82 g external pilot   91 g 5/2 mono­stable, metal seal, high pressure   91 g 5/2 mono­stable, metal seal, external pilot   90 g 5/2 bi­stable, rubber seal   90 g 5/2 bi­stable, rubber seal, external pilot 5/2 bi­stable, metal seal, high pressure 101 g 101 g 5/2 bi­stable, metal seal, external pilot 100 g 5/3 closed center, rubber seal 100 g 5/3 exhausted center, rubber seal 100 g 5/3 pressurized center, rubber seal 111 g 5/3 closed center, metal seal, high pressure 111 g 5/3 exhausted center, metal seal, high press. 5/3 pressurized center, metal seal, high press. 111 g   90 g Double 3/2 NC/NC, rubber seal   90 g Double 3/2 NO/NO, rubber seal   90 g Double 3/2 NC/NO, rubber seal

All versions available with external pilot supply. Contact SMC for delivery times.

Valve manifold for fieldbus – circular and L connection,

Ø8 mm, add valves and electrical connector

Subject to change

Part number SS5Y5-10S0-02D-C8 SS5Y5-10S0-04D-C8 SS5Y5-10S0-06B-C8 SS5Y5-10S0-08B-C8 SS5Y5-10S0-10B-C8 SS5Y5-10S0-12B-C8 SS5Y5-11S0-02D-C8 SS5Y5-11S0-04D-C8 SS5Y5-11S0-06B-C8 SS5Y5-11S0-08B-C8 SS5Y5-11S0-10B-C8 SS5Y5-11S0-12B-C8

Sub plate, side ported

■  = Delivery Ex-Stock  

Valve stations  2  4  6  8 10 12  2  4  6  8 10 12

Type Side ported Side ported Side ported Side ported Side ported Side ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported

Sub plate, bottom ported

Valve, plug-in

Valve manifold, fieldbus, ­ side ported

Valve manifold, D-sub, ­side ported

Valve manifold for D-sub connection – Ø8 mm, add valves and D-sub cable Part number SS5Y5-10F1-02D-C8 SS5Y5-10F1-04D-C8 SS5Y5-10F1-06B-C8 SS5Y5-10F1-08B-C8 SS5Y5-10F1-10B-C8 SS5Y5-10F1-12B-C8 SS5Y5-11F1-02D-C8 SS5Y5-11F1-04D-C8 SS5Y5-11F1-06B-C8 SS5Y5-11F1-08B-C8 SS5Y5-11F1-10B-C8 SS5Y5-11F1-12B-C8

Valve stations  2  4  6  8 10 12  2  4  6  8 10 12

Type Side ported Side ported Side ported Side ported Side ported Side ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported

Metal sub plate for D-sub connection – Ø8 mm, add valves and D-sub cable Part number SS5Y5-50F1-04D-C8F SS5Y5-50F1-06D-C8F SS5Y5-50F1-08B-C8F SS5Y5-50F1-10B-C8F SS5Y5-50F1-12B-C8F SS5Y5-51F1-04D-C8F SS5Y5-51F1-06D-C8F SS5Y5-51F1-08D-C8F SS5Y5-51F1-10D-C8F SS5Y5-51F1-12D-C8F

Valve stations  4  6  8 10 12  4  6  8 10 12

Type Side ported Side ported Side ported Side ported Side ported Bottom ported Bottom ported Bottom ported Bottom ported Bottom ported

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

61

So l en oid va lves, mechanical a nd ma nua l va lves

SY5000 – solenoid valve, plug-in Replacement & extension parts

4

Manifold bottom plate

End plate D-side, fieldbus

Manifold bottom plate Part number SY50M-2-1SA-C6 SY50M-2-1SA-C8 SY50M-2-1DA-C6 SY50M-2-1DA-C8 SY50M-2-2SA-C6 SY50M-2-2SA-C8 SY50M-2-2DA-C6 SY50M-2-2DA-C8

and L connection, with supply and exhaust, side ported, Ø10 mm

Side ported Side ported Side ported Side ported Bottom ported Bottom ported Bottom ported Bottom ported

Manifold bottom plate – for mixing SY3000/5000, side ported Type Single solenoid, Ø6 mm Double solenoid, Ø4 mm Double solenoid, Ø6 mm

Individual P-supply

Individual exhaust

Individual P-supply – for individual valve Part number SY50M-38-1A-C8

Type Ø8 mm

Individual exhaust – for individual valve Type Ø8 mm

Part number SY50M-1-1A-C10 SY50M-1-1AS-C10 SY50M-1-1AR-C10

Type — Built-in silencer External pilot

End plate D-side for D-sub connection – with supply and exhaust, side ported, Ø10 mm Part number SY50M-1-11A1-C10 SY50M-1-11AS1-C10 SY50M-1-11AR1-C10

Type — Built-in silencer External pilot

End plate U-side – with supply and exhaust, side ported, Ø10 mm Part number SY50M-3-1A-C10 SY50M-3-1AS-C10 SY50M-3-1AR-C10

Blanking plate

Type — Built-in silencer External pilot

DIN rail mount

Blanking plate – for unused valve stations Part number SY50M-26-1A SY50M-26-2A

Type For valve manifold For metal sub plate

DIN rail mount – for manifold, 1 mount per pack Part number SY50M-15-1A

Subject to change

Part number SY50M-39-1A-C8

End plate U-side

End plate D-side for fieldbus – circular

Type Single solenoid, Ø6 mm Single solenoid, Ø8 mm Double solenoid, Ø6 mm Double solenoid, Ø8 mm Single solenoid, Ø6 mm Single solenoid, Ø8 mm Double solenoid, Ø6 mm Double solenoid, Ø8 mm

Part number SY50M-2-3SA-C6 SY50M-2-3DA-C4 SY50M-2-3DA-C6

End plate D-side, D-sub

62

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY5000 – solenoid valve, plug-in Replacement & extension parts

P-shut-off

Check valve

P-shut-off – for individual valve Part number SY50M-50-1A

Check valve – for exhaust channels Part number SY50M-24-1A

Double check module

Sealing disc

Double check module

– maintains correct position during long stops Part number SY50M-60-1A

4

Sealing disc Part number SV2000-59-2A

Type For P-supply and exhaust (2 different ­pressures in manifold)

Electrical connections L connector cable – 34 wire Part number Type SY30M-14-4A-1-2 Connector with 1,5 m cable SY30M-14-4A-1-3 Connector with 3 m cable SY30M-14-4A-1-4 Connector with 5 m cable SY30M-14-4A-1-6 Connector with 10 m cable L connector cable – 17 wire

L connector cable

Part number Type SY30M-14-4A-2-3 Connector with 3 m cable L connector cable – 9 wire Part number Type SY30M-14-4A-3-3 Connector with 3 m cable Circular connector – 26-pin (IP67) Part number SY30M-14-5A AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

Type Circular connector Connector only Connector with 1,5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable D-sub cable with connector – 25-pin, in accordance with MIL-norm (0,3 mm2)

Circular connector

Circular connector, connector only

Circular connector, connector with cable

D-sub cable with connector

Part number Type VVZS3000-21A-2* Connector with 3 m cable VVZS3000-21A-3* Connector with 5 m cable VVZS3000-21A-4* Connector with 8 m cable Terminal box – suitable for same manifolds as fieldbus connection

Subject to change

Part number VVQC1000-T0-1

Type 20 connections (IP67)

Fieldbus – all SI-units can be used with manifolds for fieldbus, see chapter 5 For other versions, contact SMC.

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

63

So l en oid va lves, mechanical a nd ma nua l va lves

VQD1000 – 4/2 solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

4

Air or neutral gases 5 µm 0.7 MPa (7 bar) 0.0 MPa (0 bar) (vacuum: –100 kPa) –10 to 50 °C 24 V/2 W (high flow type: 3.2 W) 50 ln /min (high flow type: 70 ln /min) IP40 Push button, non-lockable Standard. Valve has no polarity

■  Direct acting  ■  High flow  ■  Compact  ■  Low weight ■  Also for vacuum (leakage ≤ 0.03 cm3/s He)  ■  Quick response time – on: 4 ms; off: 2 ms

Valve – 4/2

Blanking plate – with screws and gasket

Part number

Type Standard, including screws and gasket Standard, including plate High flow valve

VQD1151-5MO-Q VQD1151-5MO-M5-Q VQD1151U-5MO-M5-Q

Weight 34 g 54 g 54 g

Sub plate Part number VV4QD15-02M5F VV4QD15-02C4F-Q VV4QD15-04C4F-Q VV4QD15-06C4F-Q VV4QD15-08C4F-Q

Stations 2 2 4 6 8

Connection M5 4 mm 4 mm 4 mm 4 mm

Single sub plate Part number VQD1000-S-M5

Part number VVQD1000-10A-5

Connector – standard with cable Part number AXT661-14AN-30

Cable length 3000 mm

Valve mounting screw – M1.7 × 18 (spare part) Part number AXT632-7-13

Gasket – between valve and manifold (spare part) Part number VQD1000-9-1H

Connection M5

Valve

Sub plate

Blanking plate

G1/8

Part number: valve

VQD11 5 1

-5 L-

Body type

Port size

2 Body ported (single assembly) 3 Body ported (manifold assembly) 5 Plate assembly Valve options Standard, 2 W U High flow type, 3.2 W1 V Vacuum, 2 W W High flow type vacuum, 3.2 W1

Rated voltage 5 24 VDC 6 12 VDC

M5 M5 thread Without sub plate M5 M5 thread

Electrical connection L connector without cable, with LED and surge voltage suppressor M connector without cable, with MO LED and surge voltage suppressor LO

Energy saving circuit. Subject to change

1.

Body port Plate ­assembly

64

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SYJ3000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C 24 VDC (other voltages on request)/0.4 W 98 ln/min Standard: IP50 (IP65 with M8 connector) Standard: non-lockable Standard

4

■  Extremely compact  ■  Low power consumption

Valve – 5/2, 5/3, standard IP50, for sub plate assembly Part number SYJ3143-5LOU-Q SYJ3243-5LOU-Q SYJ3343-5LOU-Q SYJ3443-5LOU-Q SYJ3543-5LOU-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Blanking plug – for P-, R-channel Weight 37 g 55 g 58 g 58 g 58 g

Valve – 5/2, 5/3 with M8 connector IP65,

Connection Rc1/8

Connector – standard IP50 with cable Part number SY100-30-4A-6 SY100-30-4A-30

Cable length   600 mm 3000 mm

Connector – covered IP50 with cable

for sub plate assembly Part number SYJ3143-5WAOU-Q SYJ3243-5WAOU-Q SYJ3343-5WAOU-Q SYJ3443-5WAOU-Q SYJ3543-5WAOU-Q

Part number DXT060-67-01

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 41 g 63 g 66 g 66 g 66 g

Part number SY100-68-A-6 SY100-68-A-30

Cable length   600 mm 3000 mm

Connector – for M8 connection (IP65) Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

Sub plate

For individual assembly

G1/8

M5 × 0.8 alt. C4

Valve – 5/2, standard IP50, for individual assembly (body ported) Part number SYJ3123-5LOZ-M3-Q

Connection M3

For more types or M8 connection, contact SMC.

Pilot valve – spare part for valve with blue manual override button, new type Part number V111-5LOU V111-5WAOU

Type Standard IP50 M8, IP65

Voltage 24 VDC 24 VDC

Pilot valve – spare part for valve with orange manual override button, old type Part number SY114-5LOU-Q

Type IP50

Voltage 24 VDC

Single sub plate Part number SYJ3000-22-1-Q

Connection M5

Sub plate

Subject to change

Part number SS5YJ3-S41-02-M5F-Q SS5YJ3-S41-02-C4F-Q SS5YJ3-S41-04-M5F-Q SS5YJ3-S41-04-C4F-Q SS5YJ3-S41-06-M5F-Q SS5YJ3-S41-06-C4F-Q SS5YJ3-S41-08-M5F-Q SS5YJ3-S41-08-C4F-Q

Stations 2 2 4 4 6 6 8 8

Connection M5 Ø4 M5 Ø4 M5 Ø4 M5 Ø4

Blanking plate – for S41, with screws and gasket Part number SYJ3000-21-2A-Q

■  = Delivery Ex-Stock  

New SY – blue manual override button

Old SY – orange manual override button

Wiring for M8 (WAOU) 4 1

3

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

65

So l en oid va lves, mechanical a nd ma nua l va lves

SYJ5000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

■  Low weight and power consumption

Valve – individual or manifold assembly

Manifold plate – type 20

Part number SYJ5123-5LOU-M5-Q SYJ5223-5LOU-M5-Q SYJ5323-5LOU-M5-Q SYJ5423-5LOU-M5-Q SYJ5523-5LOU-M5-Q With M8 connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 47 g 66 g 75 g 75 g 75 g

Part number SYJ5123-5WAOU-M5-Q SYJ5223-5WAOU-M5-Q SYJ5323-5WAOU-M5-Q SYJ5423-5WAOU-M5-Q SYJ5523-5WAOU-M5-Q With DIN connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 51 g 74 g 85 g 85 g 85 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   68 g 108 g 119 g 119 g 119 g

Part number SYJ5123-5YZ-M5-Q SYJ5223-5YZ-M5-Q SYJ5323-5YZ-M5-Q SYJ5423-5YZ-M5-Q SYJ5523-5YZ-M5-Q

Part number SS5YJ5-20-02-00F-Q SS5YJ5-20-04-00F-Q SS5YJ5-20-06-00F-Q SS5YJ5-20-08-00F-Q SS5YJ5-20-10-00F-Q

Stations  2  4  6  8 10

For individual or manifold assembly G1/8 Manifold plate

Type 41: G1/8 Type 42: G1/4

G1/8 Single sub plate

Valve – plate assembly Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 45 g 62 g 73 g 73 g 73 g

Part number SYJ5143-5WAOU-Q SYJ5243-5WAOU-Q SYJ5343-5WAOU-Q SYJ5443-5WAOU-Q SYJ5543-5WAOU-Q With DIN connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 51 g 74 g 85 g 85 g 85 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   68 g 108 g 119 g 119 g 119 g

Single sub plate Part number SYJ5000-22-1F-Q

66

Sub plate

Sub plate – type 41 and 42

Part number SYJ5143-5LOU-Q SYJ5243-5LOU-Q SYJ5343-5LOU-Q SYJ5443-5LOU-Q SYJ5543-5LOU-Q With M8 connector (IP65)

Part number SYJ5143-5YZ-Q SYJ5243-5YZ-Q SYJ5343-5YZ-Q SYJ5443-5YZ-Q SYJ5543-5YZ-Q

Weight   70 g 118 g 166 g 214 g 262 g

■  = Delivery Ex-Stock  

Part number SS5YJ5-41-02-M5F-Q SS5YJ5-42-02-C6F-Q SS5YJ5-41-04-M5F-Q SS5YJ5-42-04-C6F-Q SS5YJ5-41-06-M5F-Q SS5YJ5-42-06-C6F-Q SS5YJ5-41-08-M5F-Q SS5YJ5-42-08-C6F-Q SS5YJ5-41-10-M5F-Q SS5YJ5-42-10-C6F-Q

Stations  2  2  4  4  6  6  8  8 10 10

Connection M5 Ø6 M5 Ø6 M5 Ø6 M5 Ø6 M5 Ø6

Weight   86 g   86 g 148 g 148 g 210 g 210 g 272 g 272 g 334 g 334 g

Blanking plate – with screws and gasket Part number SYJ5000-21-5A SYJ5000-21-6A

Passar Manifold plate type 20 Sub plate type 41 and 42

Blanking plug – for P-, R-channel Part number DXT060-67-01 SY5000-9-1

Connection Rc1/8 Rc1/4

Connection G1/8

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

4

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar) Up to 50 °C 24 VDC (other voltages on request)/0.4 W Individual assembly 196 ln/min; plate assembly 245 ln/min IP50 (IP65 with M8 or DIN connector) Standard: non-lockable, lockable on request. Standard

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SYJ5000 – solenoid valve Pilot valve – spare part for valve with blue (and yellow) manual override button, new type Part number V111-5LOU V111-5WAOU V115-5YZ V115-6YZ V115-3YZ V115-4YZ

Type Standard (LOU) M8 connector (WAOU) DIN connector (YZ) DIN connector (YZ) DIN connector (YZ) DIN connector (YZ)

Connector – standard IP50 with cable Voltage   24 VDC   24 VDC   24 VDC   12 VDC 110 VAC 230 VAC

Pilot valve – spare part for valve with orange manual override button, old type Part number SY114-5LOU-Q SY115-5YZ

Type Standard (LOU) DIN connector (YZ)

Part number SY100-30-4A-6 SY100-30-4A-30

Cable length   600 mm 3000 mm

Connector – covered IP50 with cable Part number SY100-68-A-6 SY100-68-A-30

Cable length   600 mm 3000 mm

Connector – for M8 connection (IP65) Voltage 24 VDC 24 VDC

Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

Wiring for M8 (WAOU)

4

4 1

3

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

Old SY – orange manual override button

Subject to change

New SY – blue manual override button

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

67

So l en oid va lves, mechanical a nd ma nua l va lves

SYJ7000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

■  Low weight and power consumption

Valve – individual or manifold assembly

Manifold plate

Part number SYJ7123-5LOU-01F-Q SYJ7223-5LOU-01F-Q SYJ7323-5LOU-01F-Q SYJ7423-5LOU-01F-Q SYJ7523-5LOU-01F-Q With M8 connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   84 g   96 g 106 g 106 g 106 g

Part number SYJ7123-5WAOU-01F-Q SYJ7223-5WAOU-01F-Q SYJ7323-5WAOU-01F-Q SYJ7423-5WAOU-01F-Q SYJ7523-5WAOU-01F-Q With DIN connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   90 g 108 g 118 g 118 g 118 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 107 g 142 g 152 g 152 g 152 g

Part number SYJ7123-5YZ-01F-Q SYJ7223-5YZ-01F-Q SYJ7323-5YZ-01F-Q SYJ7423-5YZ-01F-Q SYJ7523-5YZ-01F-Q

Part number SS5YJ7-21-02-00F-Q SS5YJ7-21-04-00F-Q SS5YJ7-21-06-00F-Q SS5YJ7-21-08-00F-Q SS5YJ7-21-10-00F-Q

Stations  2  4  6  8 10

For individual or manifold assembly

G1/8 Manifold plate

G1/4 Single sub plate

Valve – plate assembly Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   84 g   96 g 106 g 106 g 106 g

Part number SYJ7143-5WAOU-Q SYJ7243-5WAOU-Q SYJ7343-5WAOU-Q SYJ7443-5WAOU-Q SYJ7543-5WAOU-Q With DIN connector (IP65)

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   90 g 108 g 118 g 118 g 118 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 107 g 142 g 152 g 152 g 152 g

Part number SYJ7000-22-1F-Q

Sub plate

■  = Delivery Ex-Stock  

Connection G1/8

Sub plate Part number SS5YJ7-41-02-01F-Q SS5YJ7-42-02-C8F-Q SS5YJ7-41-04-01F-Q SS5YJ7-42-04-C8F-Q SS5YJ7-41-06-01F-Q SS5YJ7-42-06-C8F-Q SS5YJ7-41-08-01F-Q SS5YJ7-42-08-C8F-Q SS5YJ7-41-10-01F-Q SS5YJ7-42-10-C8F-Q

Stations  2  2  4  4  6  6  8  8 10 10

Ansl. G1/8 Ø8 G1/8 Ø8 G1/8 Ø8 G1/8 Ø8 G1/8 Ø8

Weight   400 g   400 g   600 g   600 g   800 g   800 g 1000 g 1000 g 1200 g 1200 g

Blanking plate – with screws and gasket Part number SYJ7000-21-1A-1-Q

Blanking plug – for P-, R-channel Part number SY5000-9-1

68

G1/4

Single sub plate

Part number SYJ7143-5LOU-Q SYJ7243-5LOU-Q SYJ7343-5LOU-Q SYJ7443-5LOU-Q SYJ7543-5LOU-Q With M8 connector (IP65)

Part number SYJ7143-5YZ-Q SYJ7243-5YZ-Q SYJ7343-5YZ-Q SYJ7443-5YZ-Q SYJ7543-5YZ-Q

Weight 214 g 344 g 474 g 604 g 634 g

Connection Rc1/4

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

4

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar) Up to 50 °C 24 VDC (other voltages on request)/0.4 W Individual assembly 589 ln/min; plate assembly 687 ln/min IP50 (IP65 with M8 or DIN connector) Standard: non-lockable, lockable on request Standard

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SYJ7000 – solenoid valve Pilot valve – spare part for valve with blue (and yellow) manual override button, new type Part number V111-5LOU V111-5WAOU V115-5YZ V115-6YZ V115-3YZ V115-4YZ

Type Standard (LOU) M8 connector (WAOU) DIN connector (YZ) DIN connector (YZ) DIN connector (YZ) DIN connector (YZ)

Connector – standard IP50 with cable Voltage 24 VDC 24 VDC 24 VDC 12 VDC 110 VAC 230 VAC

Pilot valve – spare part for valve with orange manual override button, old type Part number SY114-5LOU-Q SY115-5YZ

Type Standard (LOU) DIN connector (YZ)

Part number SY100-30-4A-6 SY100-30-4A-30

Cable length   600 mm 3000 mm

Connector – covered IP50 with cable Part number SY100-68-A-6 SY100-68-A-30

Cable length   600 mm 3000 mm

Connector – for M8 connection (IP65) Voltage 24 VDC 24 VDC

Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

Wiring for M8 (WAOU)

4

4 1

3

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

Old SY – orange manual override button

Subject to change

New SY – blue manual override button

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

69

So l en oid va lves, mechanical a nd ma nua l va lves

SY3000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

4

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C 24 VDC ±10% (other voltages on request)/0.4 W SY320: 196 ln/min; SY340: 216 ln/min Standard: IP50 (IP65 with M8 connector) Standard: non-lockable Standard

■  Compact: 10 mm  ■  High flow: 200 ln/min

For individual or manifold assembly

Valve – individual or manifold assembly, 24 VDC Connection M5, all ports

Valve – individual or plate assembly, M8 connector (IP65) Connection M5, all ports

Part number SY3120-5LOU-M5-Q SY3220-5LOU-M5-Q SY3320-5LOU-M5-Q SY3420-5LOU-M5-Q SY3520-5LOU-M5-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center Connection Ø4, supply and exhaust ports M5

Weight 51 g 70 g 72 g 72 g 72 g

Part number Type SY3120-5WAOU-M5-Q 5/2 mono­stable SY3220-5WAOU-M5-Q 5/2 bi­stable SY3320-5WAOU-M5-Q 5/3 closed center SY3420-5WAOU-M5-Q 5/3 exhausted center SY3520-5WAOU-M5-Q 5/3 pressurized center Connection Ø4, supply and exhaust ports M5

Weight 57 g 82 g 84 g 84 g 84 g

Part number SY3120-5LOU-C4-Q SY3220-5LOU-C4-Q SY3320-5LOU-C4-Q SY3420-5LOU-C4-Q SY3520-5LOU-C4-Q

Weight 51 g 70 g 72 g 72 g 72 g

Part number Type SY3120-5WAOU-C4-Q 5/2 mono­stable SY3220-5WAOU-C4-Q 5/2 bi­stable SY3320-5WAOU-C4-Q 5/3 closed center SY3420-5WAOU-C4-Q 5/3 exhausted center SY3520-5WAOU-C4-Q 5/3 pressurized center Connection Ø6, supply and exhaust ports M5

Weight 67 g 91 g 94 g 94 g 94 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center Connection Ø6, supply and exhaust ports M5 Part number SY3120-5LOU-C6-Q SY3220-5LOU-C6-Q SY3320-5LOU-C6-Q SY3420-5LOU-C6-Q SY3520-5LOU-C6-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 51 g 70 g 72 g 72 g 72 g

Part number SY3120-5WAOU-C6-Q SY3220-5WAOU-C6-Q SY3320-5WAOU-C6-Q SY3420-5WAOU-C6-Q SY3520-5WAOU-C6-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 63 g 87 g 90 g 90 g 90 g

For separate pilot supply (-X20), contact SMC.

Bracket – for individual valve (side bracket)

Blanking plate – with screws and gasket Part number SY3000-26-19A-Q

Bracket – for individual valve (foot bracket)

Manifold plate

Part number SX3000-16-2A

G1/8

Manifold plate – type 20 Part number SS5Y3-20-02-00F-Q SS5Y3-20-04-00F-Q SS5Y3-20-06-00F-Q SS5Y3-20-08-00F-Q SS5Y3-20-10-00F-Q SS5Y3-20-12-00F-Q

70

Stations  2  4  6  8 10 12

■  = Delivery Ex-Stock  

Weight   61 g   87 g 113 g 139 g 165 g 191 g

Blanking plug – for P-, R-channel Part number DXT060-67-01

Connection Rc1/8

Individual P-supply

– for valve on manifold plate type 20, with screws and gasket Part number SY3000-38-20A-Q

Connection M5

Individual R-exhaust

– for valve on manifold plate type 20, with screws and gasket Part number SY3000-39-20A-Q

Connection M5

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Part number SX3000-16-1A

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY3000 – solenoid valve Valve – plate assembly, 24 VDC Part number SY3140-5LOU-Q SY3240-5LOU-Q SY3340-5LOU-Q SY3440-5LOU-Q SY3540-5LOU-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 51 g 69 g 70 g 70 g 70 g

Single sub plate

Valve – plate assembly, 24 VDC With M8 connector (IP65) Part number SY3140-5WAOU-Q SY3240-5WAOU-Q SY3340-5WAOU-Q SY3440-5WAOU-Q SY3540-5WAOU-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 57 g 82 g 84 g 84 g 84 g

Blanking plate – with screws and gasket

Part number SY3000-27-1F-Q

Part number SY3000-26-9A-Q

Sub plate – type 41 Connection M5

Blanking plug – for P-, R-channel

Part number SS5Y3-41-02-M5F-Q SS5Y3-41-04-M5F-Q SS5Y3-41-06-M5F-Q SS5Y3-41-08-M5F-Q SS5Y3-41-10-M5F-Q Connection Ø6

Stations  2  4  6  8 10

Weight 110 g 170 g 230 g 290 g 350 g

Part number SS5Y3-41-02-C6F-Q SS5Y3-41-04-C6F-Q SS5Y3-41-06-C6F-Q SS5Y3-41-08-C6F-Q SS5Y3-41-10-C6F-Q SS5Y3-41-12-C6F-Q

Stations  2  4  6  8 10 12

Weight 110 g 170 g 230 g 290 g 350 g 410 g

Part number DXT060-67-01

Part number SY3000-6A-M5 SY3000-6A-C4 SY3000-6A-C6

Connection M5 Tubing Ø4 mm Tubing Ø6 mm

Individual P-supply

– for valve on sub plate type 41, with screws and gasket Part number SY3000-38-2A-Q

Connection M5

Individual R-exhaust

– for valve on sub plate type 41, with screws and gasket Part number SY3000-39-2A-Q

Connection M5

4

Plug – for unused cylinder ports Part number KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10

Plug diameter  4  6  8 10 Wiring for M8 (WAOU) 4

Sub plate

Up to 20 stations. Different dimensions of cylinder connections can be mixed on type 45-plate. Contact SMC.

Connection kit – for SY3000, A-, B-port on valve type 20

Connection Rc1/8

1

3

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

G1/8

Connector – standard IP50 with cable Part number SY100-30-4A-6 SY100-30-4A-30

Cable length   600 mm 3000 mm

Connector – covered IP50 with cable Part number SY100-68-A-6 SY100-68-A-30

Cable length   600 mm 3000 mm

Connector – for M8 connection Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

Pilot valve – spare part for valve

with blue (and yellow) manual override button, new type Part number V111-5LOU V111-5WOU

Type Standard (LOU) M8 connector (WOU)

Voltage 24 VDC 24 VDC

Pilot valve – spare part for valve with orange manual override button, old type Type Standard (LOU)

Subject to change

Part number SY114-5LOU-Q

Voltage 24 VDC New SY – blue manual override button

■  = Delivery Ex-Stock  

Old SY – orange manual override button

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

71

So l en oid va lves, mechanical a nd ma nua l va lves

SY5000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

■  Compact: 15 mm  ■  High flow: 500 ln/min

Valve – individual or manifold assembly, 24 VDC Connection Ø6, supply and exhaust ports G1/8 Part number Type SY5120-5LOU-C6F-Q 5/2 mono­stable SY5220-5LOU-C6F-Q 5/2 bi­stable SY5320-5LOU-C6F-Q 5/3 closed center SY5420-5LOU-C6F-Q 5/3 exhausted center SY5520-5LOU-C6F-Q 5/3 pressurized center SY5120-5YZ-C6F-Q 5/2 mono­stable SY5220-5YZ-C6F-Q 5/2 bi­stable SY5320-5YZ-C6F-Q 5/3 closed center SY5420-5YZ-C6F-Q 5/3 exhausted center SY5520-5YZ-C6F-Q 5/3 pressurized center SY5120-5WAOU-C6F-Q 5/2 mono­stable SY5220-5WAOU-C6F-Q 5/2 bi­stable SY5320-5WAOU-C6F-Q 5/3 closed center SY5420-5WAOU-C6F-Q 5/3 exhausted center 5/3 pressurized center SY5520-5WAOU-C6F-Q Connection Ø8, supply and exhaust ports G1/8 Part number SY5120-5LOU-C8F-Q SY5220-5LOU-C8F-Q SY5320-5LOU-C8F-Q SY5420-5LOU-C8F-Q SY5520-5LOU-C8F-Q SY5120-5YZ-C8F-Q SY5220-5YZ-C8F-Q SY5320-5YZ-C8F-Q SY5420-5YZ-C8F-Q SY5520-5YZ-C8F-Q SY5120-5WAOU-C8F-Q SY5220-5WAOU-C8F-Q SY5320-5WAOU-C8F-Q SY5420-5WAOU-C8F-Q SY5520-5WAOU-C8F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Bracket – for individual valve (side bracket) Part number SX5000-16-1A

72

■  = Delivery Ex-Stock  

Weight   91 g 111 g 116 g 116 g 116 g 112 g 153 g 158 g 158 g 158 g 116 g 161 g 166 g 166 g 166 g Weight   82 g 103 g 108 g 108 g 108 g 103 g 145 g 150 g 150 g 150 g 107 g 153 g 158 g 158 g 158 g

Part number SY5120-5LOU-01F-Q SY5220-5LOU-01F-Q SY5320-5LOU-01F-Q SY5420-5LOU-01F-Q SY5520-5LOU-01F-Q SY5120-5YZ-01F-Q SY5220-5YZ-01F-Q SY5320-5YZ-01F-Q SY5420-5YZ-01F-Q SY5520-5YZ-01F-Q SY5120-5WAOU-01F-Q SY5220-5WAOU-01F-Q SY5320-5WAOU-01F-Q SY5420-5WAOU-01F-Q SY5520-5WAOU-01F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   72 g   93 g   98 g   98 g   98 g   93 g 135 g 140 g 140 g 140 g   97 g 143 g 148 g 148 g 148 g

For separate pilot supply (-X20), contact SMC. For individual or manifold assembly

G1/4 Manifold plate

Manifold plate – type 20 Part number SS5Y5-20-02-00F-Q SS5Y5-20-04-00F-Q SS5Y5-20-06-00F-Q SS5Y5-20-08-00F-Q SS5Y5-20-10-00F-Q SS5Y5-20-12-00F-Q

Stations  2  4  6  8 10 12

Weight 136 g 208 g 280 g 352 g 424 g 496 g

Blanking plate – with screws and gasket Part number SY5000-26-1A-Q

Bracket – for individual valve (foot bracket) Part number SX5000-16-2A

Valve – individual or manifold assembly, 24 VDC Connection G1/8, all ports

Blanking plug – for P-, R-channel Part number SY5000-9-1

Connection Rc1/4

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

4

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C 24 VDC ±10% (other voltages on request)/0.4 W SY520: 500 ln/min; SY540: 520 ln/min (5/3: 400 ln/min) Standard: IP50 (IP65 with M8 or DIN connector) Standard: non-lockable Standard

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY5000 – solenoid valve Valve – plate assembly, 24 VDC Part number SY5140-5LOU-Q SY5240-5LOU-Q SY5340-5LOU-Q SY5440-5LOU-Q SY5540-5LOU-Q SY5140-5YZ-Q SY5240-5YZ-Q SY5340-5YZ-Q SY5440-5YZ-Q SY5540-5YZ-Q SY5140-5WAOU-Q SY5240-5WAOU-Q SY5340-5WAOU-Q SY5440-5WAOU-Q SY5540-5WAOU-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   61 g   81 g   87 g   87 g   87 g   82 g 123 g 129 g 129 g 129 g   65 g   89 g   95 g   95 g   95 g

Sub plate – type 41 Connection G1/8 Part number SS5Y5-41-02-01F-Q SS5Y5-41-04-01F-Q SS5Y5-41-06-01F-Q SS5Y5-41-08-01F-Q SS5Y5-41-10-01F-Q SS5Y5-41-12-01F-Q Connection Ø8

Stations  2  4  6  8 10 12

Weight 223 g 345 g 467 g 589 g 711 g 833 g

Part number SS5Y5-41-02-C8F-Q SS5Y5-41-04-C8F-Q SS5Y5-41-06-C8F-Q SS5Y5-41-08-C8F-Q SS5Y5-41-10-C8F-Q SS5Y5-41-12-C8F-Q

Stations  2  4  6  8 10 12

Weight 223 g 345 g 467 g 589 g 711 g 833 g

4

Up to 20 stations. Different dimensions of cylinder connections can be mixed on type 45-plate. Contact SMC.

Blanking plate – with screws and gasket

Wiring for M8 (WAOU)

Part number SY5000-26-2A-Q

4

Blanking plug – for P-, R-channel

1

Part number SY5000-9-1

Connection Rc1/4

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

G1/4 Sub plate

Connection kit – for SY5000, A-, B-port on valve type 20 Part number SY5000-6A-C6 SY5000-6A-C8 SY5000-6A-01F

Connection Tubing Ø6 mm Tubing Ø8 mm G1/8

Individual P-supply

– for valve on manifold plate type 20, with screws and gasket Part number SY5000-38-1A-Q

Connection R1/8

Individual R-exhaust

– for valve on manifold plate type 20, with screws and gasket Part number SY5000-39-1A-Q

Connection R1/8

Individual P-supply

– for valve on sub plate type 41, with screws and gasket Part number SY5000-38-16FA-Q

Plug – for unused cylinder ports Part number KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10

Plug diameter  4  6  8 10

Connector – standard IP50 with cable Part number SY100-30-4A-6 SY100-30-4A-30

Cable length   600 mm 3000 mm

Connector – covered IP50 with cable Part number SY100-68-A-6 SY100-68-A-30

Cable length   600 mm 3000 mm

Connector – for M8 connection

Connection R1/8

Individual R-exhaust

Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

– valve on sub plate type 41, with screws and gasket Part number SY5000-39-16FA-Q

3

Connection R1/8

Pilot valve – spare part for valve with orange manual override button, old type

Subject to change

Part number SY114-5LOU-Q

Type Standard (LOU)

Voltage 24 VDC

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type Part number V111-5LOU V111-5WOU

Type Standard (LOU) M8 connector (WOU)

■  = Delivery Ex-Stock  

Voltage 24 VDC 24 VDC

New SY – blue manual override button

Old SY – orange manual override button

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

73

So l en oid va lves, mechanical a nd ma nua l va lves

SY7000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

■  Compact: 18 mm  ■  High flow: 900 ln/min  ■  DIN connector included in valve

Valve – individual assembly, 24 VDC Connection Ø81, DIN connector (IP65) Part number Type SY7120-5YZ-C8F-Q 5/2 mono­stable SY7220-5YZ-C8F-Q 5/2 bi­stable SY7320-5YZ-C8F-Q 5/3 closed center SY7420-5YZ-C8F-Q 5/3 exhausted center SY7520-5YZ-C8F-Q 5/3 pressurized center 1 Connection Ø8 , M8 connector (IP65)

Weight 131 g 174 g 182 g 182 g 182 g

Part number Type SY7120-5WAOU-C8F-Q 5/2 mono­stable SY7220-5WAOU-C8F-Q 5/2 bi­stable SY7320-5WAOU-C8F-Q 5/3 closed center SY7420-5WAOU-C8F-Q 5/3 exhausted center SY7520-5WAOU-C8F-Q 5/3 pressurized center Connection Ø101, DIN connector (IP65)

Weight 135 g 182 g 190 g 190 g 190 g

Part number Type SY7120-5YZ-C10F-Q 5/2 mono­stable SY7220-5YZ-C10F-Q 5/2 bi­stable SY7320-5YZ-C10F-Q 5/3 closed center SY7420-5YZ-C10F-Q 5/3 exhausted center SY7520-5YZ-C10F-Q 5/3 pressurized center Connection Ø101, M8 connector (IP65)

Weight 126 g 169 g 177 g 177 g 177 g

Part number Type SY7120-5WAOU-C10F-Q 5/2 mono­stable SY7220-5WAOU-C10F-Q 5/2 bi­stable SY7320-5WAOU-C10F-Q 5/3 closed center SY7420-5WAOU-C10F-Q 5/3 exhausted center SY7520-5WAOU-C10F-Q 5/3 pressurized center Connection G1/41, DIN connector (IP65)

Weight 130 g 177 g 185 g 185 g 185 g

Part number Type SY7120-5YZ-02F-Q 5/2 mono­stable SY7220-5YZ-02F-Q 5/2 bi­stable SY7320-5YZ-02F-Q 5/3 closed center SY7420-5YZ-02F-Q 5/3 exhausted center SY7520-5YZ-02F-Q 5/3 pressurized center Connection G1/41, M8 connector (IP65)

Weight 125 g 167 g 175 g 175 g 175 g

Part number SY7120-5WAOU-02F-Q SY7220-5WAOU-02F-Q SY7320-5WAOU-02F-Q SY7420-5WAOU-02F-Q SY7520-5WAOU-02F-Q 1.

Type 5/2 monostable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

For individual assembly

G1/4 Manifold plate

Bracket – for individual valve (side bracket) Part number SX7000-16-1A

Bracket – for individual valve (foot bracket) Part number SX7000-16-2A

Manifold plate – type 20 Part number SS5Y7-20-02-00F-Q SS5Y7-20-04-00F-Q SS5Y7-20-06-00F-Q SS5Y7-20-08-00F-Q SS5Y7-20-10-00F-Q SS5Y7-20-12-00F-Q

Stations  2  4  6  8 10 12

Weight 150 g 236 g 322 g 408 g 494 g 580 g

Blanking plate – with screws and gasket Part number SY7000-26-1A-Q

Weight 129 g 175 g 183 g 183 g 183 g

Note! Exhaust ports = G1/8, supply port 1 (P) = G1/4.

For separate pilot supply (-X20), contact SMC.

74

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

4

Air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C 24 VDC ±10% (other voltages on request)/0.45 W SY7120/7220: 882 ln/min; SY7320/7420: 650 ln/min Standard: IP65 with DIN or M8 connector Standard: non-lockable Standard

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY7000 – solenoid valve Valve – plate assembly, 24 VDC Part number SY7140-5YZ-Q SY7240-5YZ-Q SY7340-5YZ-Q SY7440-5YZ-Q SY7540-5YZ-Q SY7140-5WOU-Q SY7240-5WOU-Q SY7340-5WOU-Q SY7440-5WOU-Q SY7540-5WOU-Q

Sub plate – type 42, connection G1/4

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 113 g 155 g 158 g 158 g 158 g   96 g 121 g 124 g 124 g 124 g

Supplied complete with connector, LED and surge voltage suppressor.

Part number SS5Y7-42-02-02F-Q SS5Y7-42-04-02F-Q SS5Y7-42-06-02F-Q SS5Y7-42-08-02F-Q SS5Y7-42-10-02F-Q SS5Y7-42-12-02F-Q

Stations  2  4  6  8 10 12

Weight   351 g   551 g   751 g   951 g 1151 g 1351 g

Up to 20 stations.

Blanking plate – with screws and gasket Part number SY7000-26-22A-Q

Blanking plug – for P, R connection Part number SY5000-9-1

Connection Rc1/4

4

G1/4 Sub plate

Connection kit – for SY7000 Part number SY7000-6A-C8 SY7000-6A-C10 SY7000-6A-02F

Plug – for unused cylinder ports Connection Tubing Ø8 mm Tubing Ø10 mm G1/4

Individual P-supply

– for valve on manifold plate type 20, with screws and gasket Part number SY7000-38-1FA-Q

Connection R1/4

Individual R-exhaust

– for valve on manifold plate type 20, with screws and gasket Part number SY7000-39-1FA-Q

Connection R1/4

Individual P-supply

Plug diameter   4 mm   6 mm   8 mm 10 mm

Connector – spare part, DIN43650C Part number K41 K43

Type Standard (YZ) LED + surge voltage suppressor, 24 VDC (YZ)

Connector – for M8 connection Part number WX-83S-6 WX-83S-20

Cable length   600 mm 2000 mm

For more cable types, see chapter 5.

– for valve on sub plate type 42, with screws and gasket Part number SY7000-38-16FA-Q

Part number KQ2P-04 KQ2P-06 KQ2P-08 KQ2P-10

Connection G1/4

Individual R-exhaust

Wiring for M8 (WAOU) 4 1

3

– for valve on sub plate type 42, with screws and gasket Part number SY7000-39-16FA-Q

Connection G1/4

Pilot valve – spare part for valve with orange manual override button, old type Part number SY115-5YZ-Q

Type DIN connector (YZ)

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

Voltage 24 VDC

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type Type M8 connector (WOU) DIN connector (YZ)

Subject to change

Part number V111-5WOU V115-5YZ

Voltage 24 VDC 24 VDC

New SY – blue manual override button

■  = Delivery Ex-Stock  

Old SY – orange manual override button

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

75

So l en oid va lves, mechanical a nd ma nua l va lves

SY9000 – solenoid valve Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

■  Expandable ALU manifold  ■  Replaces VF5000

Valve – individual or manifold assembly type 23 Connection Ø121, DIN connector (IP65) Part number Type SY9120-5YZ-C12F-Q 5/2 mono­stable SY9220-5YZ-C12F-Q 5/2 bi­stable SY9320-5YZ-C12F-Q 5/3 closed center SY9420-5YZ-C12F-Q 5/3 exhausted center SY9520-5YZ-C12F-Q 5/3 pressurized center 1 Connection Ø12 , M8 connector (IP65) Part number SY9120-5WAOU-C12F-Q SY9220-5WAOU-C12F-Q SY9320-5WAOU-C12F-Q SY9420-5WAOU-C12F-Q SY9520-5WAOU-C12F-Q 1.

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Note! Supply and exhaust ports (1, 3, 5) = G1/4.

Part number SS5Y9-23-02-00F-Q SS5Y9-23-04-00F-Q SS5Y9-23-06-00F-Q SS5Y9-23-08-00F-Q SS5Y9-23-10-00F-Q SS5Y9-23-12-00F-Q SS5Y9-23-14-00F-Q SS5Y9-23-16-00F-Q

Stations  2  4  6  8 10 12 14 16

Blanking plate – with screws and gasket Part number SY9000-26-1A-Q

Connection Tubing Ø8 mm Tubing Ø10 mm Tubing Ø12 mm G3/8

Weight 264 g 311 g 335 g 335 g 335 g

Note! Supply and exhaust ports (1, 3, 5) = G1/4.

For individual or manifold assembly

Manifold plate, type 23

G3/8

Individual P-supply

– for valve on manifold plate type 23, with screws and gasket Part number SY9000-38-1FA-Q

Part number SY9000-61-2A

Part number SY9000-50-1A Note! New tensile bolts required.

Tensile bolt – for assembling manifold plate Part number SY9000-23-  = number of valve stations

– for valve on manifold plate type 23, with screws and gasket

■  = Delivery Ex-Stock  

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Station expansion part – for expanding manifold plate

Connection kit – for SY9000

76

Part number SY9120-5WAOU-03F-Q SY9220-5WAOU-03F-Q SY9320-5WAOU-03F-Q SY9420-5WAOU-03F-Q SY9520-5WAOU-03F-Q

Weight 260 g 303 g 327 g 327 g 327 g

– for pressure or exhaust zoning

Part number SY9000-GS-1

Part number SY9000-39-1FA

Weight 293 g 340 g 364 g 364 g 364 g

Part number Type SY9120-5YZ-03F-Q 5/2 mono­stable SY9220-5YZ-03F-Q 5/2 bi­stable SY9320-5YZ-03F-Q 5/3 closed center SY9420-5YZ-03F-Q 5/3 exhausted center SY9520-5YZ-03F-Q 5/3 pressurized center 1 Connection G3/8 , M8 connector (IP65)

P- or R-blocking disc

Valve ­ mounting kit – with screws and gasket

Individual R-exhaust

Weight 289 g 332 g 356 g 356 g 356 g

1.

Manifold plate – type 23, expandable

Part number SY9000-6A-C8 SY9000-6A-C10 SY9000-6A-C12 SY9000-6A-03F

Valve – individual or manifold assembly type 23 Connection G3/81, DIN connector (IP65)

Nut – for tensile bolt Part number SY9000-25-1

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

4

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.10 MPa (1.0 bar); 5/3 with center position: 0.20 MPa (2.0 bar) Up to 50 °C 24 VDC ±10% (other voltages on request)/0.45 W 1700 ln/min Standard: IP65 with DIN or M8 connector Standard: non-lockable (lockable on request) Standard

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY9000 – solenoid valve Part number: sub plate – type 43, expandable

SS5Y9-43- 05 D P/R port output

No of valve stations 02 2 stations   20 20 stations

U D B

U-side For 2–10 stations D-side Båda For 2–20 stations Supply/exhaust

Internal pilot (standard) R External pilot S Internal pilot with built-in silencer RS External pilot with built-in silencer

02 03 C8 C10 C12 M

- C12

-

A/B port size

Thread

1/4" 3/8" Push-in, Ø8 mm Push-in, Ø10 mm Push-in, Ø12 mm Mixed

F N T

-Q Options

Rc G NPT NPTF

Direct mounting Mounted on DIN rail For mounting D0 on DIN rail D

4

Valve – sub plate assembly type 43 With DIN connector Part number SY9140-5YZ-Q SY9240-5YZ-Q SY9340-5YZ-Q SY9440-5YZ-Q SY9540-5YZ-Q With M8 connection (IP65) Part number SY9140-5WOU-Q SY9240-5WOU-Q SY9340-5WOU-Q SY9440-5WOU-Q SY9540-5WOU-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 196 g 239 g 263 g 263 g 262 g

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 179 g 205 g 229 g 229 g 229 g

Blanking plate – with screws and gasket Part number SY9000-26-2A-Q

Valve mounting kit – with screws and gasket Part number SY9000-GS-2

Individual R-exhaust Part number SY9000-39-2FA-Q

– for expanding sub plate, A/B connection Part number SY9000-50-2A-C8 SY9000-50-2A-C10 SY9000-50-2A-C12 SY9000-50-2A-02F SY9000-50-2A-03F

Connection   8 mm 10 mm 12 mm G1/4 G3/8

Tensile bolt – for assembling sub plate  = number of valve stations

– for valve on sub plate type 43, with screws and gasket Part number SY9000-38-2FA-Q

Nut – for tensile bolt Part number SY9000-25-1

P- or R-blocking disc

DIN rail mount

– for pressure or exhaust zoning

Part number SY9000-30-1A

Part number SY9000-57-1A

Valve mounting screw – M3 × 42, nickel plated Subject to change

Station expansion part

Part number SY9000-23-

Individual P-supply

■  = Delivery Ex-Stock  

Sub plate, type 43

Note! New tensile bolts required

– for valve on sub plate type 43, with screws and gasket

Part number SY9000-18-2

1 (P) + 3/5 (R) connections Ø12 mm

Push-in fitting Part number VVQ4000-50B-C8 VVQ4000-50B-C10 VVQ4000-50B-C12

Connection   8 mm 10 mm 12 mm

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

77

So l en oid va lves, mechanical a nd ma nua l va lves

SY9000 – solenoid valve Port block – with female thread for sub plate type 43 Part number SY9000-58A-02F SY9000-58A-03F

Connector – spare part, DIN43650C

Connection G1/4 G3/8

Blanking plug – for P, R connection

4

Type Standard (YZ) LED + surge voltage suppressor, 24 VDC (YZ)

Connector – for M8 connection

Part number SY9000-62-1A

Part number WX-83S-6 WX-83S-20

Pilot valve – spare part for valve with blue (and yellow) manual override button, new type Part number V111-5LOU V111-5WOU V115-5YZ

Part number K41 K43

Type Standard (LOU) M8 connector (WOU) DIN connector (YZ)

Type For M8 connection with 0.6 m cable For M8 connection with 2 m cable

For more cable types, see chapter 5.

Voltage 24 VDC 24 VDC 24 VDC

Pilot valve – spare part for valve with orange manual override button, old type Part number SY114-5LOU-Q SY115-5YZ-Q

Type Standard (LOU) DIN connector (YZ) Wiring for M8 (WAOU)

Voltage 24 VDC 24 VDC New SY – blue manual override button

Old SY – orange manual override button

4 1

3

Subject to change

1 Not used 3 –+ (minus or plus) 4 +– (plus or minus)

78

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VF3000 & -5000 – solenoid valve Medium Degree of filtration Max. working pressure

Air, lubricated or not lubricated 10 µm 1 MPa (10 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.15 MPa (1.5 bar) –10 to 50 °C 24 VDC –15 to +10% (other voltages on request)/1.5 W VF3000: 750–870 ln/min; VF5000: 2450 ln/min IP65 Lockable See connectors

Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Ports in plate

Ports on valve

■  Robust design  ■  G1/4 ≈ 1000 ln/min  ■  G3/8 ≈ 2500 ln/min

Valve VF3000 – for plate assembly, ports in plate, 24 VDC

Valve VF3000 – individual assembly, ports on valve, G1/4, 24 VDC Part number VF3130K-5YOD1-02F VF3230K-5YOD1-02F VF3330K-5YOD1-02F VF3430K-5YOD1-02F VF3530K-5YOD1-02F

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 214 g 311 g 328 g 328 g 328 g

For 220 VAC, replace 5YOD1 with 4YOD1. Example: VF3130K-4YOD1-02F.

Manifold plate – for VF3000 Part number VV5F3-30-021-00F VV5F3-30-041-00F VV5F3-30-061-00F VV5F3-30-081-00F

Number of stations 2 4 6 8

Blanking plate – with screws and gaskets

Pilot valve – spare part

Part number VF5120K-5YOE1-03F VF5220K-5YOE1-03F VF5320K-5YOE1-03F

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center

Weight 335 g 426 g 463 g 463 g 463 g Weight 335 g 426 g 463 g

For 220 VAC, replace 5YOD/E1 with 4YOD/E1. Example: VF5520K-4YOD1-03F.

Subject to change

Manifold plate – for VF5000 Part number VV5F5-20-021-00F VV5F5-20-041-00F VV5F5-20-061-00F VV5F5-20-081-00F

■  = Delivery Ex-Stock  

Sub plate – for VF3000, cylinder port G1/4 Part number VV5F3-40-022-02F VV5F3-40-042-02F VV5F3-40-062-02F VV5F3-40-082-02F

Number of stations 2 4 6 8

Connector Type Standard LED + surge voltage suppressor, 24 VDC Light + surge voltage suppressor, 220 VAC

Blanking plate – with screws and gaskets

Valve VF5000 – individual assembly, ports on valve, G3/8, 24 VDC Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center With push/turn manual override

Weight 228 g 324 g 342 g 342 g

Note! Connector ordered separately.

Type   24 VDC 220 VAC

Part number VF5120K-5YOD1-03F VF5220K-5YOD1-03F VF5320K-5YOD1-03F VF5420K-5YOD1-03F VF5520K-5YOD1-03F

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center

For 220 VAC, replace 5YOD1 with 4YOD1. Example: VF3140K-4YOD1.

Part number X31 X32 X30

Part number DXT031-38-5A

Part number V212K-5 V212K-4

Part number VF3140K-5YOD1 VF3240K-5YOD1 VF3340K-5YOD1 VF3440K-5YOD1

4

Number of stations 2 4 6 8

Part number VF5000-70-2A

Pilot valve – spare part Part number V212K-5 V212K-4

Type   24 VDC 220 VAC

Connector Part number X31 X32 X30

Type Standard LED + surge voltage suppressor, 24 VDC Light + surge voltage suppressor, 220 VAC

Note! Connector ordered separately.

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

79

So l en oid va lves, mechanical a nd ma nua l va lves

SY3060 – valve manifold, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

4

Compressed air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W) 170 ln/min IP50 or IP65 (M8 connector) Standard: lockable (push) Standard

■  Compact, low weight  ■  Extremely simple and flexible  ■  Few parts to stock

➌ D-side

Manifold assembly kit



– includes supply and exhaust block, end plates and DIN rail

➊ ➎

➋ ➍

Part number SS5Y3-60-02D-Q SS5Y3-60-04D-Q SS5Y3-60-06D-Q SS5Y3-60-08D-Q SS5Y3-60-10D-Q SS5Y3-60-12B-Q

Stations  2  4  6  8 10 12

Weight 110 g 170 g 230 g 290 g 350 g 410 g

Plug kit

➊ Valve – cassette type, 24 VDC, connection Ø6 mm, IP50 Part number SY3160-5LOU-C6-Q SY3260-5LOU-C6-Q SY3360-5LOU-C6-Q SY3460-5LOU-C6-Q SY3560-5LOU-C6-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 51 g 73 g 76 g 76 g 76 g

➊ Valve – M8 connector, 24 VDC, connection Ø6 mm, IP65 Part number SY3160-5WAOU-C6-Q SY3260-5WAOU-C6-Q SY3360-5WAOU-C6-Q SY3460-5WAOU-C6-Q SY3560-5WAOU-C6-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Also available with M5 thread and connection Ø4 mm.

➋ Supply and exhaust block Part number SY3000-55-1A-Q

Connection Ø8 mm

Includes gaskets SY3000-52-5A.

➌➍ End plates, D- and U-side Part number SY3000-56-1A-Q SY3000-56-1B-Q

Description End plate, D-side End plate, U-side

➎ Gaskets – 3 st Part number SY3000-52-5A

80

■  = Delivery Ex-Stock  

Weight 55 g 81 g 84 g 84 g 84 g

Part number SY3000-52-6A

Description Plugs for channel 1, 3 and 5

Connection kit – A and B port Part number SY3000-6A-M5 SY3000-6A-C4 SY3000-6A-C6

Connection M5 Ø4 mm Ø6 mm

Connector Part number SY100-30-4A SY100-30-4A-6 SY100-30-4A-10 SY100-30-4A-15 SY100-30-4A-20 SY100-30-4A-25 SY100-30-4A-30 SY100-30-4A-50 SY100-68-A-6 SY100-68-A-30 V100-49-1-1 V100-49-1-2 V100-49-1-3 V100-49-1-4 V100-49-1-5

Description 0.3 m cable 0.6 m cable 1 m cable 1.5 m cable 2 m cable 2.5 m cable 3 m cable 5 m cable 0.6 m cable, covered, IP50 enclosure 3 m cable, covered, IP50 enclosure M8, 0.3 m cable M8, 0.5 m cable M8, 1 m cable M8, 2 m cable M8, 5 m cable

Pilot valve – 24 VDC Part number SY114-5LOU-Q V111-5LOU V111-5WAOU

Description For valve with orange manual override button For valve with blue manual override button M8 connector, for valve with blue manual override button

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

U-side

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY5060 – valve manifold, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Compressed air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W) 450 ln/min Standard: IP65 (IP50 on request) Standard: lockable (push) Standard

4

■  Compact, low weight  ■  Extremely simple and flexible  ■  Few parts to stock

➌ D-side

➋ ➊ ➎

➋ ➍

U-side

➊ Valve – cassette type, 24 VDC, connection Ø6 mm, IP65 Part number SY5160-5LOU-C6-Q SY5260-5LOU-C6-Q SY5360-5LOU-C6-Q SY5460-5LOU-C6-Q SY5560-5LOU-C6-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   88 g 111 g 117 g 117 g 117 g

➊ Valve – cassette type, 24 VDC, connection Ø8 mm, IP65 Part number SY5160-5LOU-C8-Q SY5260-5LOU-C8-Q SY5360-5LOU-C8-Q SY5460-5LOU-C8-Q SY5560-5LOU-C8-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   80 g 103 g 109 g 109 g 109 g

➊ Valve – DIN connector, 24 VDC, connection G1/8, IP65 Part number SY5160-5DZ-01F-Q SY5260-5DZ-01F-Q SY5360-5DZ-01F-Q SY5460-5DZ-01F-Q SY5560-5DZ-01F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight   90 g 136 g 142 g 142 g 142 g

➋ Supply and exhaust block Part number SY5000-55-1A-Q

Connection Ø10 mm

Includes gaskets SY5000-52-3A.

➌➍ End plates, D- and U-side Part number SY5000-56-1A-Q SY5000-56-1B-Q

Description End plate, D-side End plate, U-side

➎ Gaskets – 3 st Part number SY5000-52-3A

Manifold assembly kit

– includes supply and exhaust block, end plates and DIN rail Part number SS5Y5-60-02D-Q SS5Y5-60-04D-Q SS5Y5-60-06D-Q SS5Y5-60-08D-Q SS5Y5-60-10D-Q SS5Y5-60-12B-Q

Stations  2  4  6  8 10 12

Weight 141 g 145 g 150 g 154 g 159 g 163 g

Subject to change

➊ Valve – M8 connector, 24 VDC, connection G1/8, IP65 Part number SY5160-5WAOU-01F-Q SY5260-5WAOU-01F-Q SY5360-5WAOU-01F-Q SY5460-5WAOU-01F-Q SY5560-5WAOU-01F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

■  = Delivery Ex-Stock  

Weight   71 g 102 g 108 g 108 g 108 g

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

81

So l en oid va lves, mechanical a nd ma nua l va lves

SY5060 – valve manifold, cassette type Plug kit

Connector

Part number SY5000-52-4A

Description Plugs for channel 1, 3 and 5

Connection kit – A and B port Part number SY5000-6A-C6 SY5000-6A-C8 SY5000-6A-01F

4

Connection Ø6 mm Ø8 mm G1/8

Part number SY100-30-4A SY100-30-4A-6 SY100-30-4A-10 SY100-30-4A-15 SY100-30-4A-20 SY100-30-4A-25 SY100-30-4A-30 SY100-30-4A-50 SY100-68-A-6 SY100-68-A-30 SY100-61-3-05 V100-49-1-1 V100-49-1-2 V100-49-1-3 V100-49-1-4 V100-49-1-5

Description 0.3 m cable 0.6 m cable 1 m cable 1.5 m cable 2 m cable 2.5 m cable 3 m cable 5 m cable 0.6 m cable, covered, IP50 enclosure 3 m cable, covered, IP50 enclosure DIN connector, 24 VDC M8, 0.3 m cable M8, 0.5 m cable M8, 1 m cable M8, 2 m cable M8, 5 m cable

Pilot valve – 24 VDC Part number SY114-5LOU-Q V111-5LOU V115-5DZ

Subject to change

V111-5WAOU

Description For valve with orange manual override button For valve with blue manual override button DIN connector, for valve with blue manual override button M8 connector, for valve with blue manual override button

82

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SY7060 – valve manifold, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage Flow Enclosure Manual override LED, surge voltage suppressor

Compressed air, lubricated or not lubricated 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar) Up to 50 °C Standard: 24 VDC ±10% (other voltages on request)/0.4 W (low power: 0.1 W) 980 ln/min Standard: IP65 (IP50 on request) Standard: lockable (push) Standard

4

■  Compact, low weight  ■  Extremely simple and flexible  ■  Few parts to stock

➌ D-side

➌➍ End plates, D- and U-side



Part number SY7000-56-1A-Q SY7000-56-1B-Q

➊ ➎

Description End plate, D-side End plate, U-side

➎ Gaskets – 3 st Part number SY7000-70-1A

➋ ➍

Manifold assembly kit

– includes supply and exhaust block, end plates and DIN rail

U-side

➊ Valve – DIN connector, 24 VDC, connection G1/4, IP65 Part number SY7160-5DZ-02F-Q SY7260-5DZ-02F-Q SY7360-5DZ-02F-Q SY7460-5DZ-02F-Q SY7560-5DZ-02F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 126 g 170 g 178 g 178 g 178 g

➊ Valve – DIN connector, 24 VDC, connection Ø10 mm, IP65 Part number SY7160-5DZ-C10-Q SY7260-5DZ-C10-Q SY7360-5DZ-C10-Q SY7460-5DZ-C10-Q SY7560-5DZ-C10-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Weight 146 g 191 g 199 g 199 g 199 g

➊ Valve – M8 connector, 24 VDC, connection G1/4, IP65 Part number SY7160-5WAOU-02F-Q SY7260-5WAOU-02F-Q SY7360-5WAOU-02F-Q SY7460-5WAOU-02F-Q SY7560-5WAOU-02F-Q

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center

Subject to change

Weight 225 g 231 g 237 g 244 g 250 g 256 g

Plug kit Part number SY7000-70-2A

Description Plugs for channel 1, 3 and 5

Connection kit – A and B port Part number SY7000-6A-C8 SY7000-6A-C10 SY7000-6A-02F

Connection   Ø8 mm Ø10 mm G1/4

Connector Part number SY100-61-3-05 V100-49-1-1 V100-49-1-2 V100-49-1-3 V100-49-1-4 V100-49-1-5

Connection Ø10 mm

Part number V115-5DZ

Includes gaskets SY7000-70-1A.

V111-5WAOU

■  = Delivery Ex-Stock  

Stations  2  4  6  8 10 12

Description DIN connector, 24 VDC M8, 0.3 m cable M8, 0.5 m cable M8, 1 m cable M8, 2 m cable M8, 5 m cable

Pilot valve – 24 VDC

➋ Supply and exhaust block Part number SY7000-75-1A-Q

Weight 129 g 157 g 165 g 165 g 165 g

Part number SS5Y7-60-02D-Q SS5Y7-60-04D-Q SS5Y7-60-06D-Q SS5Y7-60-08D-Q SS5Y7-60-10D-Q SS5Y7-60-12B-Q

Description DIN connector, for valve with blue manual override button M8 connector, for valve with blue manual override button

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

83

So l en oid va lves, mechanical a nd ma nua l va lves

SJ2000 & -3000 – solenoid valve manifold, plug-in, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power

4

Flow Enclosure Manual override LED, surge voltage suppressor

Compressed air 5 µm 0.7MPa (7bar) 5/2 mono­stable: 0.15 MPa (1.5 bar) 5/2 bi­stable: 0.1 MPa (1 bar) 5/3 with center position: 0.2 MPa (2 bar) 5/4 double 3/2: 0.15 MPa (1.5 bar) –10 to 50 °C Standard 24 VDC ±10%; SJ2000: 0.55 W; SJ3000: 0.4 W SJ2000: 80 ln/min; SJ3000: 120 ln/min IP50 Standard: non-lockable (lockable [push/turn] on request) LED, diode protection

■  Two valve sizes on same manifold, 7 mm and 10 mm  ■  Modern connections between valves (card edge) ■  Ideal cost-effective valve system together with fieldbus EX510 ■  Optional smart features: switch for electrical disconnection of valve; pressure regulator module; valve unit for vacuum/ejection

Valve SJ2000 – plug-in, 24 VDC

Valve SJ3000 – plug-in, 24 VDC

Part number Type SJ2160-5CU-C4 5/2 mono­stable SJ2260-5CU-C4 5/2 bi­stable SJ2360-5CU-C4 5/3 closed center SJ2460-5CU-C4 5/3 exhausted center SJ2560-5CU-C4 5/3 pressurized center SJ2A60-5CU-C4 5/4, 2 × 3/2, NC NC SJ2B60-5CU-C4 5/4, 2 × 3/2, NO NO SJ2C60-5CU-C4 5/4, 2 × 3/2, NC NO With individual electrical connection

Part number Type SJ3160-5CU-C6 5/2 mono­stable SJ3260-5CU-C6 5/2 bi­stable SJ3360-5CU-C6 5/3 closed center SJ3460-5CU-C6 5/3 exhausted center SJ3560-5CU-C6 5/3 pressurized center SJ3A60-5CU-C6 5/4, 2 × 3/2, NC NC SJ3B60-5CU-C6 5/4, 2 × 3/2, NO NO SJ3C60-5CU-C6 5/4, 2 × 3/2, NC NO With individual electrical connection

Part number SJ2160-5MOZ-C4 SJ2260-5MOZ-C4 SJ2360-5MOZ-C4 SJ2460-5MOZ-C4 SJ2560-5MOZ-C4 SJ2A60-5MOZ-C4 SJ2B60-5MOZ-C4 SJ2C60-5MOZ-C4

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/4, 2 × 3/2, NC NC 5/4, 2 × 3/2, NO NO 5/4, 2 × 3/2, NC NO

Part number SJ3160-5MOZ-C6 SJ3260-5MOZ-C6 SJ3360-5MOZ-C6 SJ3460-5MOZ-C6 SJ3560-5MOZ-C6 SJ3A60-5MOZ-C6 SJ3B60-5MOZ-C6 SJ3C60-5MOZ-C6

Type 5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/4, 2 × 3/2, NC NC 5/4, 2 × 3/2, NO NO 5/4, 2 × 3/2, NC NO

Subject to change

Since SJ is a new valve series, additional stocking may occur. Contact SMC for current stock status.

84

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SJ2000 & -3000 – solenoid valve manifold, plug-in, cassette type Valve manifold – SJ2000, D-sub connector Part number SS5J2-60FD1-02D SS5J2-60FD1-04D SS5J2-60FD1-06D SS5J2-60FD1-08D SS5J2-60FD1-10D SS5J2-60FD1-12B

Type   2 valve stations   4 valve stations   6 valve stations   8 valve stations 10 valve stations 12 valve stations

Valve manifold – SJ30001, D-sub connector Part number SS5J3-60FD1-02D SS5J3-60FD1-04D SS5J3-60FD1-06B SS5J3-60FD1-08B SS5J3-60FD1-10B SS5J3-60FD1-12B

Type   2 valve stations   4 valve stations   6 valve stations   8 valve stations 10 valve stations 12 valve stations

1. For mix of SJ2000 and -3000, add “M” in the part number. Example: SS5J3-M60-FD1-02D.

Valve manifold – SJ2000, for fieldbus EX510 Part number SS5J2-60S6BND-02D SS5J2-60S6BND-04D SS5J2-60S6BND-06B SS5J2-60S6BND-08B SS5J2-60S6BND-10B SS5J2-60S6BND-12B

Type   2 valve stations   4 valve stations   6 valve stations   8 valve stations 10 valve stations 12 valve stations

Valve manifold accessories Part number SJ3000-50-1A-C8 SJ3000-50-1AS-C8 SJ3000-50-1AR-C8 SJ3000-50-1ARS-C8 SJ3000-53-1A SJ3000-42-1A-1 SJ3000-42-3A-2 SJ3000-53-2A SJ3000-44-1A SJ3000-155-1A SJ3000-49-1A SJ3000-49-2A SJ3000-00-P SJ3000-00-P-H

Type Supply/exhaust block, internal pilot Supply/exhaust block, internal pilot, built-in silencer Supply/exhaust block, external pilot Supply/exhaust block, external pilot, built-in silencer End plate for U-side Power supply block, D-sub, D-side Power supply block, 20-pin flat cable for EX510, D-side End plate, PC wiring, D-side Blocking disc, exhaust Labels for indication of supply/exhaust block Blanking plate for single solenoid Blanking plate for double solenoid Pressure regulator block with top-mounted pressure gauge, adjust with screwdriver Pressure regulator block with top-mounted pressure gauge, knob for adjusting

4

Valve manifold – SJ30001, for fieldbus EX510 Part number SS5J3-60S6BND-02D SS5J3-60S6BND-04D SS5J3-60S6BND-06B SS5J3-60S6BND-08B SS5J3-60S6BND-10B SS5J3-60S6BND-12B

Type   2 valve stations   4 valve stations   6 valve stations   8 valve stations 10 valve stations 12 valve stations

Subject to change

1. For mix of SJ2000 and -3000, add “M” in the part number. Example: SS5J3-M60S6BND-02D.

Since SJ is a new valve series, additional stocking may occur. Contact SMC for current stock status.

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

85

So l en oid va lves, mechanical a nd ma nua l va lves

VQC1000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure

4

Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar) Up to 50 °C (dry air) Standard: 24 VDC ±10% (12 VDC on request)/0.4 W See table below IP67, factory-assembled in Japan; otherwise IP65; D-sub or flat cable, IP50 Standard: non-lockable Standard

■ Unmatched flexibility and easy configuration because of new internal connector technology

Valve – plug-in, 24 VDC 1

Part number VQC1101N-51 VQC1100N-51 VQC1201N-51 VQC1200N-51 VQC1301N-51 VQC1401N-51 VQC1501N-51 VQC1A01N-51 VQC1B01N-51 VQC1C01N-51 1.

B

Type 5/2 mono­stable, rubber seal 5/2 mono­stable, metal seal 5/2 bi­stable, rubber seal 5/2 bi­stable, metal seal 5/3 closed center, rubber seal 5/3 exhausted center, rubber seal 5/3 pressurized center, rubber seal Double 3/2 NC/NC, rubber seal Double 3/2 NO/NO, rubber seal Double 3/2 NC/NO, rubber seal

Flow 250 ln/min 180 ln/min 250 ln/min 180 ln/min 180 ln/min 250 ln/min 180 ln/min 160 ln/min 160 ln/min 160 ln/min

Weight 67 g 67 g 77 g 77 g 77 g 77 g 77 g 77 g 77 g 77 g

C

D

Manual override versions

For lockable manual override, add B, C or D at end of part number. Example: VQC1101N-51B.

Parallel fitting

Replacement fitting

– basic type, add electrical connection below Part number VV5QC11-02C6SD0 VV5QC11-04C6SD0 VV5QC11-06C6SD0 VV5QC11-08C6SD0 VV5QC11-10C6SD0 VV5QC11-12C6SD0

Stations  2  4  6  8 10 12

Additions – for sub plates above Additions Built-in silencer (…SD0-S) Manifold 13–24 valve stations/added station1 Separate pilot supply (…SD0-R)/manifold 1.

Note! Manifold specification required; contact SMC.

Electrical connections – interface modules Part number VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-M26-1 VVQC1000-T0-1 VVQC1000-L25-0-1 VVQC1000-L25-1-1 VVQC1000-L25-2-1

Type D-sub, 25-pin Flat cable, 26-pin Circular connector, 26-pin (IP67) Terminal box, 20 connections (IP67) Molded cable, 0.6 m Molded cable, 1.5 m Molded cable, 3 m

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5

86

■  = Delivery Ex-Stock  

Part number VVQ1000-50A-  = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Parallel fitting – 2 valve stations Part number VVQ1000-52A-C8

Silencer – for exhaust Part number AN200-KM8

90° connection Part number VVQ1000-F-L-  = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Blanking plate – for unused valve stations Part number VVQ1000-10A-1

Blanking plug – in place of unused connections Part number KQ2P-  = 04 for Ø4 mm; 06 for Ø6 mm.

Blanking plug – in place of fitting Part number VVQ0000-58A

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Sub plates

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC1000 – solenoid valve, plug-in Individual P-supply

Name plate

Part number VVQ1000-P-1-C6

Part number VVQ1000-N-  = number of valve stations.

Blocking disc – supply

DIN rail brackets – 1 pair

Part number VVQ1000-16A

Part number VVQ1000-57A

Individual R-exhaust

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number VVQ1000-R-1-C6

Part number VVZS3000-21A-2* VVZS3000-21A-3* VVZS3000-21A-4*

Blocking disc – exhaust Part number VVQC1000-19A-D-C6 VVQC1000-19A-S-C6

Type Double solenoid Single solenoid

4

Circular connector – 26-pin (IP67), with cable Part number AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

On VVQC1000, entire plate is replaced.

Check valve – prevents back pressure from R-channel Part number VVQ1000-18A

Expansion part – standard Part number VVQC1000-1A-D-C6 VVQC1000-1A-S-C6

Type Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Type Connector only Connector with 1.5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

For output modules VQC1000 – electrical accessories, see EX250/-500 fieldbus. For other versions, contact SMC. For fieldbus components, see chapter 5.

Type For double solenoid For single solenoid

1

2

3

4

5

6

7

8

9

Part number: valve – for valve manifold, see next page

VQC 1 1 0 0 N - 5 Individual P-supply

Blocking disc – supply

Name plate

Series VQC1000





➊  Function 1 2 3 4 5 A B C Individual R-exhaust

Blocking disc – exhaust

1.

5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center Double 3/2 NC/NC1 Double 3/2 NO/NO1 Double 3/2 NC/NO1 Only available with rubber seal.

0 1

Metal seal Rubber seal

➌  Options

Subject to change

B K N R U-side Valve stations 1 2 3 4 5 6 7 8 Valve stations are numbered in ascending order, starting from D-side

■  = Delivery Ex-Stock  

➍ ➎



➍ Rated voltage 5 6

24 VDC1 12 VDC

1. Fieldbus connection only available for 24 VDC.

➎  LED/surge voltage suppressor E

With Without LED, with surge voltage suppressor1

1. Not for fieldbus connection.

➋  Seal type

D-side



1

Standard (0.4 W) Quick response time (12 ms)1 High pressure (1 MPa)2 Negative common External pilot3

➏  Manual override B C D

Non-locking push type (tool required) Locking for screwdriver (tool required) Locking type (manual) Locking sliding type (manual)

When more than one option is desired, enter them in alphabetical order. 1. 0.95 W 2. Only available with metal seal, 0.95 W. 3. Not available for double 3/2 valve.

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

87

So l en oid va lves, mechanical a nd ma nua l va lves

VQC1000 – solenoid valve, plug-in Part number: valve manifold – for VQC1000 plate assembly/plug-in unit

VV5QC 1 1 - 08 C6 FD1 VV5QC 1 1 - 08 C6 SDQ ➊

Plate assembly/plug-in

CM L3 L4 L6 L5 B3 B4 B6 B5 LM

Push-in, Ø3.2 mm Push-in, Ø4 mm Push-in, Ø6 mm M5 thread Mixed sizes or with port plug Top-connected angle with push-in, Ø3.2 mm Top-connected angle with push-in, Ø4 mm Top-connected angle with push-in, Ø6 mm M5 thread Bottom-connected angle with push-in, Ø3.2 mm Bottom-connected angle with push-in, Ø4 mm Bottom-connected angle with push-in, Ø6 mm M5 thread Angle connector, mixed sizes

When selecting CM/LM, enter size in manifold specification sheet.

P conn.

C3 C4 C6 M5

L conn. T conn.

➋  Cylinder port size

M conn.

Maximum number of valve stations depends on chosen electrical connection. See Electrical connection/cable length.

F conn.

➊ Number of valve stations 01 1 station  













➌  Electrical connection/cable length Input D-side FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3

➎  Input block (only entered when Valve stations2

Connection/cable length D-sub connector (25P) without cable D-sub connector (25P) w. 1.5 m cable D-sub connector (25P) w. 3 m cable D-sub connector (25P) w. 5 m cable Flat cable (26P) without cable Flat cable (26P) with 1.5 m cable Flat cable (26P) with 3 m cable Flat cable (26P) with 5 m cable

1 to 12 (24)

1 to 12 (24)

Flat cable (20P) without cable1

1 to 9 (18)

TD0

Terminal connection in box

1 to 10 (20)

LD0 LD1 LD2 MD0 MD1 MD2 MD3

Cable (25 wire), 0.6 m wire length Cable (25 wire), 1.5 m wire length Cable (25 wire), 3 m wire length Multipole connector (26P) without cable Multipole connector (26P) with 1.5 m cable Multipole connector (26P) with 3 m cable Multipole connector (26P) with 5 m cable Distributed fieldbus (EX500) For fieldbus without fieldbus node With fieldbus node for Remote I/O With fieldbus node for DeviceNet/ PROFIBUS-DP/CC-LINK Fieldbus with in- and outputs (EX250) For fieldbus without fieldbus node Fieldbus for DeviceNet Fieldbus for PROFIBUS-DP Fieldbus for CC-LINK Fieldbus for CANopen AS-i, 8 in/8 out, 31-slave model, 2 ­power supplies AS-i, 4 in/4 out, 31-slave model, 2 ­power supplies AS-i, 8 in/8 out, 31-slave model, 1 ­power supply AS-i, 4 in/4 out, 31-slave model, 1 ­power supply Fieldbus with outputs (EX126)

SDA2 SD0 SDQ SDN SDV SDY SDTA SDTB SDTC SDTD

SDVB

1 to 12 (24)

1 to 8 (16)

1 to 12 (24) 1 to 4 (8) 1 to 2 (4) 1 to 4 (8) 1 to 2 (4)

— — ✔ — — ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔

CC-LINK

EX126 Remote I/O

CC-LINK

PROFIBUSDP

DeviceNet

CANopen

AS-i

CC-LINK

PROFIBUSDP

EX500

1 2 3

Without input block M12, 2 inputs M12, 4 inputs M8, 4 inputs (3 pins)

➐  Polarity, input block (only entered when input blocks are used)

PNP (+) or without ­fieldbus node/ input block NPN (–)

➑  Options None All stations with backpressure check valves1 With DIN rail D (rail length: standard) With DIN rail D (rail length: special)2 Special wiring K (not double wiring)3 N With name plate R External pilot4 Direct exhaust with S built-in silencer 5 B

➍  Fieldbus polarity DeviceNet

➏  Type of input block (only

N

1. P connection: Order cables separately for type 20P. 2. Numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

Polarity +COM N –COM

Without fieldbus node/ input block (SD0) 0 Without input block 1 With 1 input block   8 With 8 input blocks

1 to 12 (24)

1 to 8 (16)

Fieldbus for CC-LINK

EX250

input blocks are used)

entered when input blocks are used)

PDC

SD0 SDA1

S connection

4



F / P / T / L / M connection S connection



Specify options in alphabetical order. Example: BRS. 1. When using backpressure check valves only on neccessary stations, enter check valve part number and valve station number in manifold specification sheet. 2. For special DIN rail length, enter D. ( = number of valve stations.) Example: D08. In this case, manifold is mounted on DIN rail for 8 stations, regardless of actual number of stations in manifold. Entered number of stations must be larger than actual number of stations in manifold. Enter D0 for options without DIN rail. 3. Ensure that wiring is entered in manifold specification sheet. 4. For external pilot option “R”, also enter external pilot option “R” for valves in question. 5. Option with built-in silencer does not meet requirement of IP67.



Leave box for fieldbus polarity blank for manifold without bus node (SD0).

88

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Series VQC1000

B -B

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC1000 – solenoid valve, plug-in Exploded view VQC1000 End plate, D-side

Valve station, base

End plate, U-side

EX250

Electrical connection and fieldbus

EX500 D-sub Flat cable

P connection

Single wire

T connection L connection M connection

Multipole conn.

Subject to change

Terminal conn.

F connection

EX126

EX600

S connection (fieldbus)

EX260

4

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

89

So l en oid va lves, mechanical a nd ma nua l va lves

VQC2000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure

4

Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar); metal seal (not double 3/2): 0.1 MPa (1 bar) Up to 50 °C (dry air) Standard: 24 VDC ±10% (12 VDC on request)/0.4 W See table below IP67, factory-assembled in Japan; otherwise I IP65; D-sub or flat cable, IP50 Standard: non-lockable Standard

■ Unmatched flexibility and easy configuration because of new internal connector technology

Valve – plug-in, 24 VDC 1

Part number VQC2101N-51 VQC2100N-51 VQC2201N-51 VQC2200N-51 VQC2301N-51 VQC2401N-51 VQC2501N-51 VQC2A01N-51 VQC2B01N-51 VQC2C01N-51

Type 5/2 mono­stable, rubber seal 5/2 mono­stable, metal seal 5/2 bi­stable, rubber seal 5/2 bi­stable, metal seal 5/3 closed center, rubber seal 5/3 exhausted center, rubber seal 5/3 pressurized center, rubber seal Double 3/2 NC/NC, rubber seal Double 3/2 NO/NO, rubber seal Double 3/2 NC/NO, rubber seal

Flow 800 ln/min 600 ln/min 800 ln/min 600 ln/min 600 ln/min 800 ln/min 600 ln/min 460 ln/min 460 ln/min 460 ln/min

Weight   95 g 105 g 105 g 105 g 105 g 105 g 105 g 105 g 105 g 105 g

Sub plates

Part number VV5QC21-02C8SD0 VV5QC21-04C8SD0 VV5QC21-06C8SD0 VV5QC21-08C8SD0 VV5QC21-10C8SD0 VV5QC21-12C8SD0

Stations  2  4  6  8 10 12

Additions – for sub plates above Additions Built-in silencer (…SD0-S) Manifold 13–24 valve stations/added station1 Separate pilot supply (…SD0-R)/manifold Note! Manifold specification required; contact SMC.

Electrical connections – interface modules Part number VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-M26-1 VVQC1000-T0-1 VVQC1000-L25-0-1 VVQC1000-L25-1-1 VVQC1000-L25-2-1

Type D-sub, 25-pin Flat cable, 26-pin Circular connector, 26-pin (IP67) Terminal box, 20 connections (IP67) Molded cable, 0.6 m Molded cable, 1.5 m Molded cable, 3 m

Fieldbus – EX250, EX500 and EX600, see chapter 5

■  = Delivery Ex-Stock  

Blanking plate

Replacement fitting

– basic type, add electrical connection below.

90

D

For lockable manual override, add B, C or D at end of part number. Example: VQC2101N-51B.

Parallel fitting

1.

C

Part number VVQ1000-51A-  = C4 for Ø4 mm; C6 for Ø6 mm; C8 for Ø8 mm.

Parallel fitting – 2 valve stations Part number VVQ2000-52A-C10

Silencer – for exhaust Part number AN200-KM10

Blanking plate – for unused valve stations Part number VVQ2000-10A-1

Blanking plug – in place of unused connections Part number KQ2P-  = 04 for Ø4 mm; 06 for Ø6 mm; 08 for Ø8 mm.

Blanking plug – in place of fitting Part number VVQ1000-58A

Individual P-supply Part number VVQ2000-P-1-C8

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

1.

B Manual override versions

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC2000 – solenoid valve, plug-in Sandwichmodul – for individual P-shut-off

Name plate

Part number VVQ2000-24A-1

Part number VVQ2000-N-  = number of valve stations.

Blocking disc – supply

DIN rail brackets – 1 pair

Part number VVQ2000-16A

Part number VVQ2000-57A

Individual R-exhaust

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2)

Part number VVQ2000-R-1-C8

Part number VVZS3000-21A-2* VVZS3000-21A-3* VVZS3000-21A-4*

Blocking disc – exhaust Part number VVQ2000-19A

Type Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

4

Circular connector – 26-pin (IP67), with cable

Check valve – prevents back pressure from R-channel

Part number AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

Part number VVQ2000-18A

Expansion part – standard Part number VVQC2000-1A-D-C8 VVQC2000-1A-S-C8

Type For double solenoid For single solenoid

For output modules VQC2000 – electrical accessories, see EX250/-500 fieldbus. For other versions, contact SMC. For fieldbus components, see chapter 5.

Sub plate – single assembly Part number VQ2000-PW-02F VQ2000-PW-02F-XSE502

Type Connector only Connector with 1.5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Type Standard With M12 connection 8 7 6 5

Part number: valve – for valve manifold, see next page

4 3 2 1

VQC 2 1 0 0 N - 5 Series VQC2000 Individual P-supply

Blocking disc – supply

Name plate

Blocking disc – exhaust

1 2 3 4 5 A B C Sandwichmodul – for individual P-shut-off



➊  Function

1.

Individual R-exhaust



5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center Double 3/2 NC/NC1 Double 3/2 NO/NO1 Double 3/2 NC/NO1 Only available with rubber seal.

0 1

Subject to change

B K N R Valve stations 1 2 3 4 5 6 7 8 Valve stations are numbered in ascending order, starting from D-side

■  = Delivery Ex-Stock  

U-side

➍ ➎



➍ Rated voltage 5 6

24 VDC1 12 VDC

1. Fieldbus connection only available for 24 VDC.

➎  LED/surge voltage suppressor E

With Without LED, with surge voltage suppressor1

1. Not for fieldbus connection.

➋  Seal type Metal seal Rubber seal

➌  Options

D-side



1

Standard (0.4 W) Quick response time (12 ms)1 High pressure (1 MPa)2 Negative common External pilot3

➏  Manual override B C D

Non-locking push type (tool required) Locking for screwdriver (tool required) Locking type (manual) Locking sliding type (manual)

When more than one option is desired, enter them in alphabetical order. 1. 0.95 W 2. Only available with metal seal, 0.95 W. 3. Not available for double 3/2 valve.

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

91

So l en oid va lves, mechanical a nd ma nua l va lves

VQC2000 – solenoid valve, plug-in Part number: valve manifold – for VQC2000 plate assembly/plug-in unit

VV5QC 2 1 - 08 C8 FD1 VV5QC 2 1 - 08 C8 SDQ ➊

Plate assembly/plug-in

When selecting CM/LM, enter size in manifold specification sheet.

F conn. P conn.

C4 Push-in, Ø4 mm C6 Push-in, Ø6 mm C8 Push-in, Ø8 mm Mixed sizes CM or with port plug Top-connected angle L4 with push-in, Ø4 mm Top-connected angle L6 with push-in, Ø6 mm Top-connected angle L8 with push-in, Ø8 mm Bottom-connected angle B3 with push-in, Ø3 mm Bottom-connected angle B4 with push-in, Ø4 mm Bottom-connected angle B6 with push-in, Ø6 mm Bottom-connected angle B8 with push-in, Ø8 mm Angle connector, LM mixed sizes

L conn. T conn.

➋  Cylinder port size

M conn.

Maximum number of valve stations depends on chosen electrical connection. See Electrical connection/cable length.









➎  Input block (only entered when



input blocks are used)

➊ Number of valve stations 01 1 station  



➌  Electrical connection/cable length Input D-side FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3

Valve stations2

Connection/cable length D-sub connector (25P) without cable D-sub connector (25P) w. 1.5 m cable D-sub connector (25P) w. 3 m cable D-sub connector (25P) w. 5 m cable Flat cable (26P) without cable Flat cable (26P) with 1.5 m cable Flat cable (26P) with 3 m cable Flat cable (26P) with 5 m cable

1 to 12 (24)

Flat cable (20P) without cable1

1 to 9 (18)

TD0

Terminal connection in box

1 to 10 (20)

LD0 LD1 LD2 MD0 MD1 MD2 MD3

Cable (25 wire), 0.6 m wire length Cable (25 wire), 1.5 m wire length Cable (25 wire), 3 m wire length Multipole connector (26P) without cable Multipole connector (26P) with 1.5 m cable Multipole connector (26P) with 3 m cable Multipole connector (26P) with 5 m cable Distributed fieldbus (EX500) For fieldbus without fieldbus node With fieldbus node for Remote I/O With fieldbus node for DeviceNet/ PROFIBUS-DP/CC-LINK Fieldbus with in- and outputs (EX250) For fieldbus without fieldbus node Fieldbus for DeviceNet Fieldbus for PROFIBUS-DP Fieldbus for CC-LINK Fieldbus for CANopen AS-i, 8 in/8 out, 31-slave model, 2 ­power supplies AS-i, 4 in/4 out, 31-slave model, 2 ­power supplies AS-i, 8 in/8 out, 31-slave model, 1 ­power supply AS-i, 4 in/4 out, 31-slave model, 1 ­power supply Fieldbus with outputs (EX126)

SDA2 SD0 SDQ SDN SDV SDY SDTA SDTB SDTC SDTD

SDVB

1 to 12 (24) 1 to 12 (24)

1 to 8 (16)

1 to 12 (24) 1 to 4 (8) 1 to 2 (4) 1 to 4 (8) 1 to 2 (4) 1 to 8 (16)

Fieldbus for CC-LINK

➍  Fieldbus polarity

— — ✔ — — ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔

Leave box for fieldbus polarity blank for manifold without bus node (SD0).

92

■  = Delivery Ex-Stock  

CC-LINK

EX126 Remote I/O

CC-LINK

PROFIBUSDP

DeviceNet

CANopen

AS-i

CC-LINK

PROFIBUSDP

DeviceNet

Polarity +COM N –COM

EX500

entered when input blocks are used)

1 2 3

Without input block M12, 2 inputs M12, 4 inputs M8, 4 inputs (3 pins)

➐  Polarity, input block (only entered when input blocks are used)

N

PNP (+) or without fieldbus node/ input block NPN (–)

➑  Options

1. P connection: Order cables separately for type 20P. 2. Numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

EX250

Without fieldbus node/ input block (SD0) 0 Without input block 1 With 1 input block   8 With 8 input blocks

➏  Type of input block (only 1 to 12 (24)

PDC

SD0A SDA1

S connection

4



F / P / T / L / M connection S connection

✔ —

None All stations with backpressure check valves1 With DIN rail D (rail length: standard) With DIN rail D (rail length: special)2 Special wiring K (not double wiring)3 N With name plate R External pilot4 Direct exhaust with S built-in silencer 5 Branch off P- and R-ports T on U-side6 B

Specify options in alphabetical order. Example: BRS. 1. When using backpressure check valves only on neccessary stations, enter check valve part number and valve station number in manifold specification sheet. 2. For special DIN rail length, enter D. ( = number of valve stations.) Example: D08. In this case, manifold is mounted on DIN rail for 8 stations, regardless of actual number of stations in manifold. Entered number of stations must be larger than actual number of stations in manifold. Enter D0 for options without DIN rail. 3. Ensure that wiring is entered in manifold specification sheet. 4. For external pilot option “R”, also enter external pilot option “R” for valves in question. 5. Option with built-in silencer does not meet requirement of IP67. 6. SUP and EXH ports on U-side branch off (against cylinder port and solenoid) with push-in fitting.

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Series VQC2000

B -B

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC2000 – solenoid valve, plug-in Exploded view VQC2000 End plate, D-side

Valve station, base

End plate, U-side

EX250

Electrical connection and fieldbus

EX500 D-sub Flat cable

P connection

Single wire

T connection L connection M connection

Multipole conn.

Subject to change

Terminal conn.

F connection

EX126

EX600

S connection (fieldbus)

EX260

4

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

93

So l en oid va lves, mechanical a nd ma nua l va lves

VQC4000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure

4

Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 1.0 MPa (10 bar) 5/2 mono­stable: 0.2 MPa (2 bar); 5/2 bi­stable: 0.15 MPa (1.5 bar); 5/3 with center position: 0.2 MPa (2 bar); metal seal (all): 0.15 MPa (1.5 bar) Up to 50 °C (dry air) Standard: 24 VDC ±10% (12 VDC on request)/1 W See table below IP67, factory-assembled in Japan; otherwise IP65; D-sub or flat cable, IP50 Standard: non-lockable Standard

■ Unmatched flexibility and easy configuration because of new internal connector technology

Valve – plug-in, 24 VDC Part number1 VQC4101-5 VQC4100-5 VQC4201-5 VQC4200-5 VQC4301-5 VQC4401-5 VQC4501-5 1.

Type 5/2 mono­stable, rubber seal 5/2 mono­stable, metal seal 5/2 bi­stable, rubber seal 5/2 bi­stable, metal seal 5/3 closed center, rubber seal 5/3 exhausted center, rubber seal 5/3 pressurized center, rubber seal

Flow 2000 ln/min 1700 ln/min 2000 ln/min 1700 ln/min 1900 ln/min 2000 ln/min 2000 ln/min

Weight 230 g 230 g 260 g 260 g 280 g 280 g 280 g

For lockable manual override, add B at end of part number. Example: VQC4101N-5B.

Blanking plate

Sub plates

Blanking plate – for unused valve stations

– basic type, add electrical connection below. Stations  2  4  6  8 10 12

Connection G3/8 G3/8 G3/8 G3/8 G3/8 G3/8

Available with interchangeable push-in fittings Ø8, 10 or 12 mm; contact SMC. For built-in silencer, add “-S” after SD0. Example: VV5QC41-0203FSD0-S.

Sub plate – single assembly Part number VQ4000-PW-03F-Q VQ4000-PW-03F-Q-XSE502

Type Standard With M12 connection

Additions – for sub plates above 1. Note! Manifold specification required; for terminal box and 20-pin flat cable some restrictions apply; contact SMC.

Electrical connections – interface modules

VVQC1000-M26-1 VVQC1000-T0-1

Individual P-supply Part number VVQ4000-P-1-03F

Blocking disc – supply Part number VVQ4000-16A

Individual R-exhaust Part number VVQ4000-R-1-03F

Blocking disc – exhaust

Additions Manifold 13–24 valve stations/added station1

Part number VVQC1000-F25-1 VVQC1000-P20-1 VVQC1000-P26-1

Part number VVQ4000-10A-1

Type D-sub, 25-pin Flat cable, 20-pin Flat cable, 26-pin Circular connector, 26-pin (IP67) Terminal box, 20 connections (IP67)

Part number VVQ4000-16A

Throttle valve block – mounted between valve and manifold Part number VVQ4000-20A-1

For molded cable (L connection), contact SMC.

Fieldbus – EX250, EX500 and EX600, see chapter 5

94

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Part number VV5QC41-0203FSD0 VV5QC41-0403FSD0 VV5QC41-0603FSD0 VV5QC41-0803FSD0 VV5QC41-1003FSD0 VV5QC41-1203FSD0

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC4000 – solenoid valve, plug-in Pressure-controlled check valve – w. manual residual pressure relief Part number VVQ4000-25A-1

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2) Part number VVZS3000-21A-2* VVZS3000-21A-3* VVZS3000-21A-4*

Note! Can not be mounted on manifold with external pilot supply.

Individual shut-off for P-supply

Type Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Circular connector – 26-pin (IP67), with cable

Part number VVQ4000-37A-1

Part number AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

Sandwich regulator Part number ARBQ4000-00-P-1 ARBQ4000-00-A-1 ARBQ4000-00-B-1

Regulated port P A B

For output modules VQC4000 – electrical accessories, see EX250/-500 fieldbus. For other versions, contact SMC. For fieldbus components, see chapter 5.

Expansion part – standard Part number VVQC4000-1A-D-03F VVQC4000-1A-S-03F

Type Connector only Connector with 1.5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Type For double solenoid For single solenoid

Individual P-supply

Pressure-controlled check valve

Individual shut-off for P-supply

4

Sandwich regulator

U-side 8 7 Blocking disc – supply

6

4 3 Individual R-exhaust

Valve stations

5

2 1

D-side

Part number: valve – for valve manifold, see next page

VQC 4 1 0 0 Series VQC4000



➊  Function 1 2 3 4 5 6

5/2 mono­stable 5/2 bi­stable 5/3 closed center 5/3 exhausted center 5/3 pressurized center 5/3 exhausted center with pressure-controlled check valves

➋  Seal type

Blocking disc – exhaust

0 1

Metal seal Rubber seal

Subject to change

➌  Options Throttle valve block

R Y Valve stations are numbered in ascending order, starting from D-side

■  = Delivery Ex-Stock  

Standard (1 W) External pilot Low power (0.5 W)

-5





➍ ➎



➍ Rated voltage 5 6

24 VDC1 12 VDC

1. Fieldbus connection only available for 24 VDC.

➎  LED/surge voltage suppressor E

With Without LED, with surge voltage suppressor

➏  Manual override B

Non-locking push type (tool required) Locking for screwdriver (tool required)

When more than one option is desired, enter them in alphabetical order.

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

95

So l en oid va lves, mechanical a nd ma nua l va lves

VQC4000 – solenoid valve, plug-in Part number: valve manifold – for VQC4000 plate assembly/plug-in unit

VV5QC 4 1 - 08 02 TD0 VV5QC 4 1 - 08 02 SDQW





When selecting CM, enter size in manifold specification sheet.

➍  Fieldbus polarity

✔ — — — ✔ — — ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ — ✔ ✔ ✔ ✔ ✔ ✔

CC-LINK

EX126 Remote I/O

CC-LINK

PROFIBUSDP

DeviceNet

CANopen

EX500

AS-i

CC-LINK

PROFIBUSDP

EX250 DeviceNet

PROFIBUSDP

Polarity +COM N –COM

DeviceNet

EX240

✔ —

Leave box for fieldbus polarity blank for manifold without bus node (SD0).

➎  Input block (only entered when

➏  Type of input block (only

input blocks are used)

entered when input blocks are used)

Without fieldbus node/ input block (SD0) 0 Without input block 1 With 1 input block   8 With 8 input blocks

1 2 3 4

Without input block M12, 8 inputs (EX240) M12, 2 inputs (EX250) M12, 4 inputs (EX250) M8, 4 inputs (EX250)

Max. 4 for EX240 and max. 8 for EX250.

➑  Options

(only entered when input blocks are used)

N

PNP (+) or without fieldbus node/input block NPN (–)

K N

None Special wiring (not double wiring)1 With name plate (only available for T connection)2

When more than one option is desired, enter them in alphabetical order. Example: KN. 1. Ensure that wiring is entered in manifold specification sheet. 2. Mounting position for name plate is on top of terminal box cover.

Thread – for P, R, A, B port

VV5QC41-08 03 Cylinder port

TD0 Thread type F T

Rc G NPT/NPTF

S connection

➐  Polarity, input block



Input D-side FD0 FD1 FD2 FD3 PD0 PD1 PD2 PD3

Connection/cable length D-sub connector (25P) without cable D-sub connector (25P) with 1.5 m cable D-sub connector (25P) with 3 m cable D-sub connector (25P) with 5 m cable Flat cable (26P) without cable Flat cable (26P) with 1.5 m cable Flat cable (26P) with 3 m cable Flat cable (26P) with 5 m cable

Valve stations2 1 to 12 (24)

1 to 12 (24)

PDC

Flat cable (20P) without cable1

1 to 9 (18)

TD0

Terminal connection in box

1 to 10 (20)

LD0 LD1 LD2 MD0 MD1 MD2 MD3

Cable (25 wire), 0.6 m wire length Cable (25 wire), 1.5 m wire length Cable (25 wire), 3 m wire length Multipole connector (26P) without cable Multipole connector (26P) with 1.5 m cable Multipole connector (26P) with 3 m cable Multipole connector (26P) with 5 m cable Distributed fieldbus (EX500) SD0A For fieldbus without fieldbus node SDA1 With fieldbus node for Remote I/O With fieldbus node for DeviceNet/ PROFISDA2 BUS-DP/CC-LINK Fieldbus with in- and outputs (EX250) For fieldbus without fieldbus node SD0 SDQ Fieldbus for DeviceNet SDN Fieldbus for PROFIBUS-DP SDV Fieldbus for CC-LINK SDY Fieldbus for CANopen AS-i, 8 in/8 out, 31-slave model, SDTA 2 ­power supplies AS-i, 4 in/4 out, 31-slave model, SDTB 2 ­power supplies AS-i, 8 in/8 out, 31-slave model, SDTC 1 ­power supply AS-i, 4 in/4 out, 31-slave model, SDTD 1 ­power supply Fieldbus with in- and outputs (EX240) SD0W For fieldbus without fieldbus node SDQW Fieldbus for DeviceNet SDNW Fieldbus for PROFIBUS-DP SDVW Fieldbus for CC-LINK Fieldbus with outputs (EX126) SDVB

Fieldbus for CC-LINK

1 to 12 (24) 1 to 12 (24)

1 to 8 (16)

1 to 12 (24) 1 to 4 (8) 1 to 2 4) 1 to 4 (8) 1 to 2 (4)

1 to 12 (24)

1 to 8 (16)

1. P connection: Order cables separately for type 20P. 2. Numbers in paranthesis indicates maximum number of solenoids for configuration w. mixed single-double solenoid connections. Maximum number of valve stations is determined by total number of solenoids. For mixed connections, use option symbol “K”.

P- and R-ports use same thread

96

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Maximum number of valve stations depends on chosen electrical connection. See Electrical connection/cable length.

F conn.

Push-in, Ø8 mm Push-in, Ø10 mm Push-in, Ø12 mm Rc1/4 Rc3/8 Bottom-connected Rc1/4 Mixed sizes CM or with port plug

01 1 station  



➌  Electrical connection/cable length

C8 C10 C12 02 03 B

➊ Number of valve stations



P conn.

➋  Cylinder port size

Plate assembly/plug-in

4



L conn. T conn.

Series VQC4000



M conn.



F / P / T / L / M connection S connection

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

VQC4000 – solenoid valve, plug-in Exploded view VQC4000 End plate, D-side

Valve station, base

End plate, U-side

EX600

EX500

4

P conn.

D-sub Flat cable Single wire

T connection L connection M connection

Multipole conn.

Subject to change

Terminal conn.

F conn.

EX126

EX240

S connection (fieldbus)

EX260

EX250

Electrical connection and fieldbus

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

97

So l en oid va lves, mechanical a nd ma nua l va lves

VQ5000 – solenoid valve, plug-in Medium Degree of filtration Max. working pressure Min. working pressure (rubber seal/metal seal) Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

4



Compressed air, lubricated or not lubricated 5 µm 1.0 MPa (10 bar) 5/2 mono­stable: 0.2 MPa (2 bar)/0.1 MPa (1 bar); 5/2 bi­stable: 0.15 MPa (1.5 bar)/0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar)/0.15 MPa (1.5 bar) –10 to 50 °C (dry air) 24 VDC ±10% (other voltages on request)/1 W 4000 ln/min IP65 (except for D-sub) Standard: non-lockable (lockable on request) Standard

For more information, contact SMC.

■  More compact than ISO 3  ■  Lower weight  ■  More accessories

SV1000 – solenoid valve, tie rod type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar) Up to 50 °C (dry air) Standard: 24 VDC (12 VDC on request)/0.65 W 290 ln/min IP67 Standard: non-lockable Standard, valve has no polarity

■  Easy to expand, connectors between valves  ■  Highest enclosure IP67

Part number 1 SV1100-5FU SV1100R-5FU SV1200-5FU SV1200R-5FU SV1300-5FU SV1300R-5FU SV1400-5FU SV1400R-5FU SV1500-5FU SV1500R-5FU SV1A00-5FU SV1B00-5FU SV1C00-5FU 1.

Sub plates Type 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal, external pilot 5/2 bi­stable, rubber seal 5/2 bi­stable, rubber seal, external pilot 5/3 closed center, rubber seal 5/3 closed center, rubber seal, external pilot 5/3 exhausted center, rubber seal 5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal 5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, NC/NC, rubber seal 5/4 double 3/2, NO/NO, rubber seal 5/4 double 3/2, NC/NO, rubber seal

Add D for lockable manual override. Example: SV1100-5FUD.

Output modules – for electrical accessories, see EX500 fieldbus Part number SV1000-60-5A-1A SV1000-60-5B-1A 1.

98

Type1 One normally open relay output, 110 VAC/3 A, 30 VDC/3 A Two normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

Weight 66 g 66 g 71 g 71 g 73 g 73 g 73 g 73 g 73 g 73 g 71 g 71 g 71 g

– basic type1, add electrical connection below Part number SS5V1-W10S10D-02D-C6 SS5V1-W10S10D-04B-C6 SS5V1-W10S10D-06B-C6 SS5V1-W10S10D-08B-C6 SS5V1-W10S10D-10B-C6 SS5V1-W10S10D-12B-C6 SS5V1-W10S10D-14B-C6 SS5V1-W10S10D-16B-C6 SS5V1-W10S10D-18B-C6 SS5V1-W10S10D-20B-C6 1.

Number of stations  2  4  6  8 10 12 14 16 18 20

For other versions, contact SMC.

Electrical connections – interface modules Part number VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-M26-1

Type D-sub, 25-pin Flat cable, 26-pin Circular connector, 26-pin (IP67)

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5 Use interface for VQC series for sub plates above.

Load capacity for resistive loads.

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

Subject to change

Valve – plug-in

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SV1000 – solenoid valve, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar) Up to 50 °C (dry air) Standard: 24 VDC (12 VDC on request)/0.65 W 290 ln/min IP67 Standard: non-lockable Standard, valve has no polarity

4

■ Unmatched flexibility  ■  Easy to assemble, expand and modify

Valve – plug-in Part number 1 SV1100-5FU SV1100R-5FU SV1200-5FU SV1200R-5FU SV1300-5FU SV1300R-5FU SV1400-5FU SV1400R-5FU SV1500-5FU SV1500R-5FU SV1A00-5FU SV1B00-5FU SV1C00-5FU 1.

Sub plates – cassette type (16) Type 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal, external pilot 5/2 bi­stable, rubber seal 5/2 bi­stable, rubber seal, external pilot 5/3 closed center, rubber seal 5/3 closed center, rubber seal, external pilot 5/3 exhausted center, rubber seal 5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal 5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, NC/NC, rubber seal 5/4 double 3/2, NO/NO, rubber seal 5/4 double 3/2, NC/NO, rubber seal

Weight 66 g 66 g 71 g 71 g 73 g 73 g 73 g 73 g 73 g 73 g 71 g 71 g 71 g

Add D for lockable manual override. Example: SV1100-5FUD.

Output modules

– 24 VDC. For electrical accessories, see EX250/-500 fieldbus. Part number SV1000-60-5A-1A SV1000-60-5B-1A

Part number SS5V1--02D-C6 SS5V1--04D-C6 SS5V1--06D-C6 SS5V1--08D-C6 SS5V1--10D-C6 SS5V1--12B-C6 SS5V1--14B-C6 SS5V1--16B-C6 SS5V1--18B-C6

Example of part number SS5V1-W16CD-02D-C6 SS5V1-W16S0D-02D-C6 SS5V1-16FD1-02D-C6 SS5V1-16PD1-02D-C6 Number of stations  2  4  6  8 10 12 14 16 18

For other versions, contact SMC. For fieldbus components, see chapter 5.

Type1 One normally open relay output, 110 VAC/3 A, 30 VDC/3 A Two normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

Load capacity for resistive loads.

Subject to change

1.

Sub plate Multipole connection, IP67 For EX500 Gateway (Gateway parts ordered separately), IP67 D-sub connection, IP40 Flat cable connection, IP40

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

99

So l en oid va lves, mechanical a nd ma nua l va lves

Accessories for SV1000 – solenoid valve, tie rod and cassette type Replacement fitting

For manifold type 10S

Part number VVQ1000-50A-

Blocking disc – supply

 = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Silencer – for exhaust

Part number SV1000-59-1A

Part number AN203-KM8

Blocking disc – exhaust

Blanking plate

4

Part number SV1000-59-2A

Part number SV1000-67-1A

Expansion part – single solenoid

Individual P-supply

Part number SV1000-50-1A-

Part number SV1000-38-1A-C6

 = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Expansion part – double solenoid

Individual R-exhaust

Part number SV1000-50-2A-

Part number SV1000-39-1A-C6

 = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Sandwich regulator – with pressure gauge Part number SV1000-05-P SV1000-05-A1 SV1000-05-B1 SV1300-05-P SV1300-05-A1 SV1300-05-B1

Regulated port P A B P A B

For valve type Mono- and ­bi­stable

Blocking disc – supply For 3-position

Blanking plug – in place of unused connections Part number KQ2P-

Part number SX3000-77-1A

Blocking disc – exhaust Part number SX3000-77-1A

 = 03 for Ø3.2 mm; 04 for Ø4 mm; 06 for Ø6 mm.

Expansion part – single solenoid

Blanking plug – in place of fitting

Part number SV1000-50-3A-

Part number VVQ1000-58A

 = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Blocking indicator

Expansion part – double solenoid

Part number SV1000-74-1A

Part number SV1000-50-4A-

D-sub connector – 25-pin, in accordance with MIL-norm (0.3 mm2) Part number GVVZS3000-21A-2 GVVZS3000-21A-3 GVVZS3000-21A-4

For manifold type 16S

 = C3 for Ø3.2 mm; C4 for Ø4 mm; C6 for Ø6 mm.

Type Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Circular connector – 26-pin (IP67), with cable Type Connector only Connector with 1.5 m cable Connector with 3 m cable Connector with 5 m cable Connector with 8 m cable

Blanking plate

Expansion part

Subject to change

Part number AXT100-MC26 AXT100-MC26-015 AXT100-MC26-030 AXT100-MC26-050 AXT100-MC26-080

100

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

S o l e n oid va lves , mec h a n ica l a n d man u a l va lves

SV2000 – solenoid valve, tie rod type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power Flow Enclosure Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar) Up to 50 °C (dry air) Standard: 24 VDC (12 VDC on request)/0.65 W 580 ln/min IP67 Standard: non-lockable Standard, valve has no polarity

4

■  Easy to expand, connectors between valves  ■  Highest enclosure IP67

Valve – plug-in Part number 1 SV2100-5FU SV2100R-5FU SV2200-5FU SV2200R-5FU SV2300-5FU SV2300R-5FU SV2400-5FU SV2400R-5FU SV2500-5FU SV2500R-5FU SV2A00-5FU SV2B00-5FU SV2C00-5FU 1.

Sub plates Type 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal, external pilot 5/2 bi­stable, rubber seal 5/2 bi­stable, rubber seal, external pilot 5/3 closed center, rubber seal 5/3 closed center, rubber seal, external pilot 5/3 exhausted center, rubber seal 5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal 5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, NC/NC, rubber seal 5/4 double 3/2, NO/NO, rubber seal 5/4 double 3/2, NC/NO, rubber seal

Add D for lockable manual override. Example: SV2100-5FUD

Output modules – for electrical accessories, see EX500 fieldbus Part number SV2000-60-5A-1A SV2000-60-5B-1A

74 g 78 g 78 g 83 g 83 g 83 g 83 g 83 g 83 g 78 g 78 g 78 g

– basic type1, add electrical connection below Part number SS5V2-W10S10D-02D-C8 SS5V2-W10S10D-04D-C8 SS5V2-W10S10D-06D-C8 SS5V2-W10S10D-08D-C8 SS5V2-W10S10D-10D-C8 SS5V2-W10S10D-12B-C8 SS5V2-W10S10D-14B-C8 SS5V2-W10S10D-16B-C8 SS5V2-W10S10D-18B-C8 SS5V2-W10S10D-20B-C8 1.

Number of stations  2  4  6  8 10 12 14 16 18 20

For other versions, contact SMC.

Electrical connections – interface modules Part number VVQC1000-F25-1 VVQC1000-P26-1 VVQC1000-M26-1

Type D-sub, 25-pin Flat cable, 26-pin Circular connector, 26-pin (IP67)

Fieldbus – EX250, EX260, EX500 and EX600, see chapter 5 Use interface for VQC series for sub plates above.

Load capacity for resistive loads.

Subject to change

1.

Type1 One normally open relay output, 110 VAC/3 A, 30 VDC/3 A Two normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

Weight 74 g

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]

101

So l en oid va lves, mechanical a nd ma nua l va lves

SV2000 – solenoid valve, cassette type Medium Degree of filtration Max. working pressure Min. working pressure Operating temperature Voltage/power

4

Flow Enclosure Manual override LED, surge voltage suppressor

Air, lubricated or not lubricated (dry) 5 µm 0.7 MPa (7 bar) 5/2 mono­stable: 0.15 MPa (1.5 bar); 5/2 bi­stable: 0.1 MPa (1 bar); 5/3 with center position: 0.2 MPa (2 bar); double 3/2: 0.15 MPa (1.5 bar) Up to 50 °C (dry air) Standard: 24 VDC (12 VDC on request)/0.65 W 520 ln/min IP67 Standard: non-lockable Standard, valve has no polarity

■ Unmatched flexibility  ■  Easy to assemble, expand and modify

Valve – plug-in Part number 1 SV2100-5FU SV2100R-5FU SV2200-5FU SV2200R-5FU SV2300-5FU SV2300R-5FU SV2400-5FU SV2400R-5FU SV2500-5FU SV2500R-5FU SV2A00-5FU SV2B00-5FU SV2C00-5FU 1.

Sub plates – cassette type (16) Type 5/2 mono­stable, rubber seal 5/2 mono­stable, rubber seal, external pilot 5/2 bi­stable, rubber seal 5/2 bi­stable, rubber seal, external pilot 5/3 closed center, rubber seal 5/3 closed center, rubber seal, external pilot 5/3 exhausted center, rubber seal 5/3 exhausted center, rubber seal, external pilot 5/3 pressurized center, rubber seal 5/3 pressurized center, rubber seal, external pilot 5/4 double 3/2, NC/NC, rubber seal 5/4 double 3/2, NO/NO, rubber seal 5/4 double 3/2, NC/NO, rubber seal

Weight 74 g 74 g 78 g 78 g 83 g 83 g 83 g 83 g 83 g 83 g 78 g 78 g 78 g

Add D for lockable manual override. Example: SV2100-5FUD.

Output modules

– 24 VDC. For electrical accessories, see EX250/-500 fieldbus. Part number SV2000-60-5A-1A SV2000-60-5B-1A

Part number SS5V2--02D-C8 SS5V2--04D-C8 SS5V2--06D-C8 SS5V2--08D-C8 SS5V2--10D-C8 SS5V2--12B-C8 SS5V2--14B-C8 SS5V2--16B-C8 SS5V2--18B-C8

Example of part number SS5V2-W16CD-02D-C8 SS5V2-W16S0D-02D-C8 SS5V2-16FD1-02D-C8 SS5V2-16PD1-02D-C8 Number of stations  2  4  6  8 10 12 14 16 18

For other versions, contact SMC. For fieldbus components, see chapter 5.

Type1 One normally open relay output, 110 VAC/3 A, 30 VDC/3 A Two normally open relay outputs, 110 VAC/0.3 A, 30 VDC/1 A

Load capacity for resistive loads.

Subject to change

1.

Sub plate Multipole connection, IP67 For EX500 Gateway (Gateway parts ordered separately), IP67 D-sub connection, IP40 Flat cable connection, IP40

102

■  = Delivery Ex-Stock  

For more info, ask the SMC experts: Phone +31 (0) 20 531 88 88 / [email protected]