EcoSwap is a LED light engine for existing Philips Lumec outdoor lighting fixtures offering performance and longevity. EcoSwap allows you to switch to LED lighting and have great energy savings and longevity while keeping the same outdoor lighting infrastructure. It is the first and only light engine to offer luminaire thermal analysis conducted inside the luminaire which garantees the performance and longevity of the LED light engine. For retrofit, EcoSwap offers the most lumen output per watt on the market.

7'' (178mm)

Characteristics - Quick and easy tool less installation / retrofit - Better performance wattage of light output produced is 6889 lumens (best in the industry) - Optimal thermal management - Lifespan up to 100,000 hours - More than 60% in energy savings - Tested in real luminaire conditions - Tested by independent certified labs - Durable and environmentally responsible since you keep your existing lighting infrastructure

Typical Applications - Optimal for retrofit projects: Candela, Zenith, New Westminster and Contemporary Lantern - Ideal for decorative luminaires with frosted, prismatic and translucent glass globes

LED Lamp Details These LED lamp details are showing typical delivered lumens relative to the LED light engine EcoSwap only (not for the luminaire as a whole). For the data of the luminaire with EcoSwap, please refer to the technique file of the appropriate luminaire.

LED = Philips Lumileds Luxeon R, CRI = 70, CCT = 4000K (+/- 350K) LED rated life = 70,000 hrs1 - Driver rated life = 100,000 hrs Typical delivered lumens 2

Typical lamp wattage (W)

Typical system wattage3 (W)

Typical current @ 120 V (A)

Typical current @ 240 V (A)

Typical current @ 277 V (A)

LED current (mA)

40W42LED4K-R

4753

40

45

0.48

0.24

0.22

65W42LED4K-R

6889

65

70

0.72

0.36

0.32

Lamp

1 L70 = 70,000 hrs (at ambient temperature = 25°C and forward current = 500 mA). 2 May vary depending on the optical distribution used. Data provided are for the module alone, outside of a fixture. 3 System wattage includes the lamp and the LED driver. 4 Equivalence should always be confirmed by a photometric layout. Note : Due to rapid and continuous advances in LED technology, LED luminaire data is subject to change without notice and at the discretion of Philips.

1

EcoSwap

HPS equivalent4

Luminaire Efficacy Rating (Lm/W)

333

70

106

500

100

98

Optical System EcoSwap

Photometric Distributions

Rotomatic toolfree system composed of 4 main components: LED lamp / Optical System / Heat Sink / Driver

RLE3: Asymetrical RLE5: Asymetrical (Square)

Lamp Lamp type Philips Lumileds Luxeon R. Composed of 42 high performance white LEDs, 40w/65w lamp wattage. Color temperature of 4000 Kelvin nominal, 70 CRI. Operating lifespan based on LM80 results after which 50% still emits over 70% (L70) of its original lumen output. Use of a metal core board insures greater heat transfer and longer lifespan of the light engine.

Optical System Composed of high performance acrylic refractors lenses to achieve desired optimized distribution to get maximum spacing, target lumens will create a perfect lighting uniformity. Performance shall be tested by independent lab for LM63 and LM79 and TM15 (IESNA) certifying its photometric performance.

Heat Sink Made of cast aluminum optimising the LEDs efficiency and life. Product does not use any cooling device with moving parts (only passive cooling device).

Driver High power factor of 90% min. Electronic driver, operating range 50/60 Hz. Auto adjusting to a voltage between 120 and 277 volt AC rated for both application line to line or line to neutral, Class II, THD of 20% max. Maximum ambient operating temperature from -40F (-40C) to 130F (55C) degrees. Certified in compliance to cULus requirement. Dry and damp location. Assembled on a unitized removable tray with Tyco quick disconnect plug resisting to 221F (105C) degrees. The current supplying the LEDs will be reduced by the driver if the internal temperature exceeds 185F (85C), as a protection to the LEDs and the electrical components. Output is protected from short circuits, voltage overload and current overload. Automatic recovery after correction. Electrical components are RoHS compliant.

Voltages 120 / 208 / 240 / 277

Luminaire Lighting Controls DMG

Driver is compatible with dimmer from 0 to 10 volts.

Luminaire Options HS

House side shield

Ordering Example

2

Luminaire

Lamp

Optical System

Voltage

Driver Options

Luminaire Options

Finish

CAND2

40W42LED4K-R

RLE3

240

DMG

HS

GR

EcoSwap

Available with Following Luminaires *Please note, that validation is required to ensure compatibility when retrofitting EcoSwap in existing Philips Lumec luminaire installation (such as version / year, optical systems, selected options, mounting height, etc.). Please contact us for more information.

Candela New luminaire installation

CAND1 / CAND109 / CAND2 / CAND241 / CAND3 / CAND4 / CAND6

Existing luminaire installation (retrofit*)

CAND1 / CAND101 / CAND102 / CAND103 / CAND104 / CAND105 / CAND106 CAND107 / CAND108 / CAND109 / CAND2 / CAND201 / CAND222 / CAND225 CAND226 / CAND231 / CAND232 / CAND233 / CAND236 / CAND241 / CAND242 CAND243 / CAND244 / CAND3 / CAND4 / CAND6

New Westminster New luminaire installation

NW / NW201 / NW204 / NW209

Existing luminaire installation (retrofit*)

NW / NW201 / NW202 / NW203 / NW204 / NW205 / NW206 / NW207 / NW208 NW209 / NW210 / NW211

Traditional Globe Series Existing luminaire installation (retrofit*)

L23 / L29 / L50 / L51

Zenith New luminaire installation

Z10B / Z10G / Z11B / Z12 / Z12A / Z14 / Z15 / Z40 / Z40CZ40F / Z40G / Z41 Z42G / Z47A

Existing luminaire installation (retrofit*)

Z10B / Z10G / Z11 / Z11B / Z12 / Z12A / Z14 / Z15 / Z40 / Z40C / Z40F / Z40G / Z41 Z42G / Z47 / Z47A / Z47G / Z47L / Z66B / Z66A

Retrofit Kit Installation Instructions Please read these installation instructions carefully before proceeding. DISCONNECT POWER BEFORE SERVICING. Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

step 1

step 1

Step 1

Open hid luminaire by turning the globe counter clockwise and pull upwards.

Step 2

step 2

Remove the hid optic and ballast tray step 2 by turning counter clockwise. Unfasten quick-connector. Please dispose of old module in an appropriate manner.

3

EcoSwap

step 4

HID LAMP

Step 3

Remove all original labels.

Step 4

step4 4 step

Install retrofit by connecting the driver tray to the input using the quick-connector and then turn over the rotomatic plate. Note: If the connectors don’t match, use the provided cross-over patch cable. Caution: Lock by turning firmly clockwise until guide pin reaches the end.

Step 5

step5 5 step

Close Led luminaire by turning the globe clockwise.

EcoSwap Warranty When properly installed and under normal conditions of use, Philips Lumec warrants to its purchaser that the supplied LED light engine and LED power components shall be free from defects in material and workmanship in its intended use (normal wear and tear excepted) for an extended period of five (5) years from the date of invoice. For the complete EcoSwap Warranty : http://www.lumec.com/pdf/PhilipsLumec_EcoSwap_Warranty.pdf

4

EcoSwap

www.philips.com/lumec PHILIPS LUMEC HEAD OFFICE

ONTARIO OFFICE

640, Curé-Boivin Boulevard Boisbriand, Québec Canada J7G 2A7

189 Bullock Drive Markham, Ontario Canada L3P 1W4

T : 450.430.7040 F : 450.430.1453

T : 416.223.7255 F : 866.971.2825

For the details of our different agents and representatives, please consult the Contact us section of our Website. © 2012 Philips Group. All rights reserved. We reserve the right to change details of design, materials and finishes.