-- - DAR Constitution Hall Technical Information

-- - DAR Constitution Hall Technical Information Stage Elevation DAR Constitution Hall Page 2 of 16 Updated: 7/30/2015 Stage Specifications ...
Author: Julia Walters
14 downloads 1 Views 2MB Size
--

-

DAR Constitution Hall Technical Information

Stage Elevation

DAR Constitution Hall

Page 2 of 16

Updated: 7/30/2015

Stage Specifications

NO RIGGING Except at fixed points upstage of line 34'-10"

16'-11" UP



1" 19'-52



13'-6" TYP

1" 48'-82

55'-35 8"

1" 24'-28

24'-6" 19'-3"

UP

5'-3"

Piano Lift

80'-33 4"

36'

Maximum Rigging Height for Dome Points: 30'- 0"

24'-63 8"

NO RIGGING Except at fixed points upstage of line

DAR Constitution Hall

Page 3 of 16

Updated: 7/30/2015

Stage Extension The stage of DAR Constitution Hall may be extended in a wide variety of patterns to accommodate larger events. The on site equipment includes fifty pieces of 4’ x 8’ Wenger Versalite staging and two Wenger adjustable stair units. The same pieces can be used for camera platforms, press platforms and stage risers. DAR Constitution Hall must arrange all stage extensions. See schedule of rates for pricing.

When employing the full stage extension, 274 seats in rows A through G become physically unusable.

Optional Stage Extension up to 80’ by 20’

-60 Box seats are just off from the stage, with 40 of them looking at the back of the performer. -404 Tier seats are also looking downstage toward the back of the performer.

4’

1st Possible Seated Row B

Preferred First Row C

8’

D

D

12’

E

F

16’

G

G

20

H

H

Stage Extension

DAR Constitution Hall

Page 4 of 16

Total Number of Seats = 3702 Physical Kills = 274 Obstructed Box Seats = 60 Obstructed Tier Seats = 404 **************************** Total Remaining Seats = 2964

Updated: 7/30/2015

Sound, Power & Spot Lights Power Specifications 100 amps 3 phase @ Bridge FOH

200 amps 3 phase Field Ground

400 amps 200 amps 100 amps 3 phase 600 amps 400 amps 200 amps 3 phase

Additional Power:  200 amps 3 phase in dressing room 1 (C street shore power)  6 x 20amp 110 volt circuits on either side upstage wall  2 x 20 amp circuits in each floor pocket

Sound Specifications

Delay Cluster

Equipment:      

Meyer M1-D Line Array main speakers Delay cluster of Meyer UPA speakers KF650 speaker side hangs Crest power amps Clark Technik digital delays Yamaha and Digitech equalizers

Right Array

Left Array

Spotlights 2000 watt Xenon Super

2000 watt Xenon Super

2 x 2000 watt Xenon Super Troupers in booth

Equipment: 4 Strong Xenon Supertroopers Intercom system with Clearcom power and headsets.

DAR Constitution Hall

Page 5 of 16

Updated: 7/30/2015

Lighting DAR Lighting Truss     

56’ 2’x2’ Box Truss 71’ from the Downstage edge 10 x Source 4 Pars 6 x Source 4 10° on Right Arm Auto Yolks 2 x Source 4 10°

Upstage Color LEDs A system of fully customizable color LED fixtures installed amid the upstage architecture, highlighting the original design of the Hall.

 25 Color Kinetics ColorBlast 12 PowerCore (Cove)  20 iColor Cove MX PowerCore (Eagles)  iPlayer 3 Controller/DMX interface

DAR Constitution Hall

Page 6 of 16

Updated: 7/30/2015

Rigging Specifications Roof Steel Schematic

DAR Constitution Hall

Page 7 of 16

Updated: 7/30/2015

Rigging Specifications Ceiling Steel Schematic

DAR Constitution Hall

Page 8 of 16

Updated: 7/30/2015

Loading Entrances

NOTE: All scenery and support items must fit through all three-door sizes to make it to the stage. Any scenery over 18'-0" in length, must be hand carried into the building through the 18th Street Entrance.

DAR Constitution Hall

Page 9 of 16

Updated: 7/30/2015

Seating Chart

* Access for persons with disabilities on D Street * Box Office on C Street

DAR Constitution Hall

Page 10 of 16

Updated: 7/30/2015

Stage Level Dressing Rooms Conductors Room Mens Room

Stage Right House Lights

Operations Office

Ladies Room

Blair Suite

Stage Left

Lafayette Room

Show Office

Restricted

Technical Director

C St. Lobby Event Coordinator

DAR Constitution Hall

Page 11 of 16

Managing Director

Updated: 7/30/2015

Lower Level Dressing Rooms Up To Stage

IA, Local 22 Crew Room

Restricted Storage

Dressing Room 4

Dressing Room 3

Dressing Room 2

Piano Lift

Dressing Room 5

Catering

C St.

Laundry Machines

Restricted

Dressing Room 1

DAR Constitution Hall

Mens Room

Page 12 of 16

Ladies Room

Updated: 7/30/2015

Lobby & Lounge D Street Entrance for Patrons with Disabilities

DN

Elevator

18th Street

Elevator

Lower Lounge Ladies Restroom

Main Entrance to Hall

Box Office

Box Office

C Street Over 10,000 square feet of space suitable for receptions, displays or exhibitions

DAR Constitution Hall

Page 13 of 16

Updated: 7/30/2015

Building Map All Parking must be arranged in advance with the DC Government, as the meters must be permitted for indicated parking arrangements.

DAR Constitution Hall

Page 14 of 16

Updated: 7/30/2015

Building Photo & Local Map

M

F Street

3 E Street

2 D Street

5

1

1 7 t h S t r e e t

White House

The Ellipse

MAP KEY 1 5 t h S t r e e t

1. The National Society Daughters of the American Revolution 2. The American Red Cross 3. The Corcoran Gallery of Art 4. The Organization Of American States 5. DAR Constitution Hall

C Street

4 Constitution Avenue

Washington Monument

DAR Constitution Hall

Page 15 of 16

Updated: 7/30/2015

Contacts REQUIRED VENDORS: CONCESSIONS: Best Vending

India Robinson

(301) 404-1793

EVENT SECURITY: Falcon Security

Regi Miner

(202) 251-8080

[email protected]

USHERS AND TICKET TAKERS: Theater Services Karin Long

(301) 424-9747

[email protected]

TICKETING SERVICES: Ticketmaster

(301) 955-1340

[email protected]

(301) 341-1092

[email protected]

Ned Haskin Bob Goldstein Mike Scarfe

(301) 322-2805 (410) 448-1400 (301) 733-9337

[email protected] [email protected] [email protected]

Robert Halem

(301) 341-1092 (301) 585-2100

[email protected] [email protected]

Stephen Smith

(703)742-7520

[email protected]

BJ Singh

(410) 242-5050

[email protected]

(202) 744-8823

[email protected]

Sally Reilly

STAGEHANDS, RIGGERS AND SEAT REMOVAL: GLP, Inc. Robert Halem

[email protected]

RECOMMENDED VENDORS: SOUND: Acoustic Design Maryland Sound MHA Audio LIGHTING: GLP, Inc. Atmosphere Lighting VIDEO/PROJECTION: Quince Imaging PRODUCTION SERVICES: Event EQ

BOX OFFICE STAFFING: Brave Soul Tix Monte Wolf PIANO TUNING: David Sapp** designated Piano Technician Jerry Brubaker CATERING: Taste Event Catering Brett Bond Hightopps James Bell LIMOUSINE: Duckett's Limousine Gregg Duckett EVENT DÉCOR: Hargrove Ron Bracco Legacy Scenic Chris Gagen FURNITURE RENTALS: EventsBum Pat Barnes THEATRICAL DRAPERIES: Drapes and Drops Leonard Weiss VALET SERVICES: Atlantic Services Group STREET PARKING METERS: DC DOT

DAR Constitution Hall

(703) 378-8335 (301) 336-6727 (443) 250-3338 (410) 347-5551

[email protected] [email protected]

(301) 577-7501

[email protected]

(301) 306-9000 (703) 961-8866

[email protected] [email protected]

(240) 988-3915

[email protected]

(703) 823-4434

[email protected]

(202) 466-5050

(202) 466-7194 fax

(202) 442-4670

http://tops.ddot.dc.gov/

Page 16 of 16

Updated: 7/30/2015